Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “detector response”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

Preliminary test data using the MOS DRO with Si:In detector material

The initial testing performed on the Hughes Metal Oxide Semiconductor Direct Readout (MOS DRO) with a Si:In extrinsic infrared array is described. The testing to date was of a screening nature and the results are primarily qualitative rather than quantitative. At a later date the performance optimization phase will be initiated. An encouraging result is that this response is strongly dependent on the detector temperature, to the extent that thermal transients introduced during the chip readout will affect the performance. A responsivity of 1 A/W at 2.2 microns with a bias of 15 volts, which is well below what is optimum bias, was obtained.

Fowler, A. M.↗

Thermal response of large area high temperature superconducting YBaCuO infrared bolometer

Thermal analysis of large area high temperature superconducting infrared detector operating in the equilibrium mode (bolometer) was performed. An expression for the temperature coefficient beta=1/R(dR/dT) in terms of the thermal conductance and the thermal time constant of the detector were derived. A superconducting transition edge bolometer is a thermistor consisting of a thin film superconducting YBaCuO evaporated into a suitable thermally isolated substrate. The operating temperature of the bolometer is maintained close to the midpoint of the superconducting transition region where the resistance R has a maximum dynamic range. A detector with a strip configuration was analyzed and an expression for the temperature rise (delta T) above the ambient due to a uniform illumination with a source of power density P(sub i) was calculated. An expression for the thermal responsivity of the detector was derived using the thermal diffusion analysis with appropriate boundary conditions. It was found that the thermal responsibility depends upon the spatial modulation frequency and the angular frequency of the incoming radiation. The problem of the thermal cross talk between different detector elements was addressed. In the case of monolithic HTS detector array with a row of square elements of dimensions 2a and CCD or CID readout electronics the thermal spread function was derived for different spacing between elements. This analysis can be critical for future design and applications of large area focal plane arrays as broad band optical detectors made of granular thin films HTS YBaCuO.

Khalil, Ali E.↗

Guidance and control research

Guidance and control research - Josephson junction memory elements, frequency response of thin film thermal detectors, gallium selenide barrier gate, and photoconductor metal contacts

Source record↗

The nuclear radiation monitor for the Spacelab/Shuttle

A 5 inch by 5 inch diameter sodium iodide scintillation crystal, viewed by a 5 inch photomultiplier was designed to be mounted near the center of the shuttle payload bay to quantitatively measure the neutron and gamma ray environment during the second Spacelab mission. The expected energy resolution is 8% FWHM at 662 keV. The detector will operate in an energy range from 0.1 to 20 MeV. A charged anticoincidence shield consisting of a 1 cm thick plastic scintillator viewed by three 2 inch photomultiplier tubes, covers the crystal detector which has nearly omnidirectional response.

Fishman, G. J.↗

Fundamentals of absolute pyroheliometry and objective characterization

The radiometric methodology in use with a narrow field of view radiometer for observation of the solar constant is described. The radiation output of the Sun is assumed to be constant, enabling the monitoring of the solar source by an accurately pointed radiometer, and the Sun's output is measured as a function of time. The instrument is described, its angular response considered, and principles for absolute radiometric measurement presented. Active modes of operation are analyzed, taking into consideration instrumental perturbations and sensor efficiency, heating wire effect, cavity sensor efficiency, thermal effects on the surface of the sensitive area, the effect of the field of view limiting system, and the frequency response of the heat flux detector and absolute radiometric system. Performance of absolute measurements with relatively high accuracy is demonstrated.

Crommelynck, D. A.↗

Time and energy dependence of the cosmic ray gradient in the outer heliosphere

Pioneers 10 and 11, now 35 and 18 AU from the Sun, continue to extend our knowledge of the spatial dependence of cosmic ray intensities in the heliosphere. Radial gradients measured from these spacecraft by UCSD detectors which have integral energy responses above thresholds of 80 and 500 MeV/nucleon are reported. An average gradient of 2%/AU typifies the data set as a whole, but there are time and energy dependences that deviate from this value. With operating lifetimes of 13 and 12 years, respectively, for the two spacecraft, the time dependence was followed for over a solar cycle. The higher energy channel shows less modulation on all time scales. At the start of the present cycle, the gradient is lower than the average value during the last solar cycle.

Fillius, W.↗

A redshift survey of IRAS galaxies. I - Sample selection

A complete all-sky sample of objects, flux-limited at 60 microns, has been extracted from the data base of the IRAS. The sample consists of 5014 objects, of which 2649 are galaxies and 13 are not yet identified. In order to study large-scale structure with this sample, it must be free of systematic biases. Corrections are applied for a major systematic effect in the flux densities listed in the IRAS Point Source Catalog: sources resolved by the IRAS beam have flux densities systematically underestimated. In addition, accurate flux densities are obtained for sources flagged as variable, or of moderate flux quality at 60 microns. The IRAS detectors suffered radiation-induced responsivity enhancement (hysteresis) due to crossings of the satellite scans across the Galactic plane; this effect is measured and is shown to be negligible.

Strauss, Michael A.↗

Model for the computation of self-motion in biological systems

A technique is presented by which direction- and speed-tuned cells, such as those commonly found in the middle temporal region of the primate brain, can be utilized to analyze the patterns of retinal image motion that are generated during observer movement through the environment. The developed model determines heading by finding the peak response in a population of detectors or neurons each tuned to a particular heading direction. It is suggested that a complex interaction of multiple cell networks is required for the solution of the self-motion problem in the primate brain.

Perrone, John A.↗

Characteristics of the HYDICE sensor

In 1992, in an effort to significantly improve knowledge in the field of hyperspectral imagery, the Naval Research Laboratories defined a set of requirements for a new generation sensor. Construction of this instrument, designated HYDICE, has recently been completed at Hughes Danbury Optical Systems. It is currently being flight tested on a Convair 580 operated by ERIM. This paper reports on some of the performance parameters measured to date. The majority of these are derived from laboratory test data. Optomechanical parameters include MTF, spatial co-registration, 'smile', spectral profile and spectral calibration. Detector-related parameters include system responsivity, signal to noise ratio, radiometric stability and gain linearity. The results are compared with the original system performance predictions.

Basedow, R. W.↗

Study of the Polarization Properties of the Crab Nebula and Pulsar with BATSE

Activities carried out under this proposal included: 1) development and refinements of Monte Carlo simulations of the atmospheric reflected albedo hard x-ray emissions, both unpolarized and polarized, 2) modeling and simulations of the off-axis response of the BATSE LAD detectors, and 3) comparison of our simulation results with numerous BATSE flare and cosmic burst data sets.

Forrest, David J.↗

Two-Step Calibration of a Multiwavelength Pyrometer for High Temperature Measurement Using a Quartz Lamp

There is no theoretical upper temperature limit for pyrometer application in temperature measurements. NASA Glenn's multiwavelength pyrometer can make measurements over wide temperature ranges. However, the radiation spectral response of the pyrometer's detector must be calibrated before any temperature measurement is attempted, and it is recommended that calibration be done at temperatures close to those for which measurements will be made. Calibration is a determination of the constants of proportionality at all wavelengths between the detector's output (voltage) and its input signals (usually from a blackbody radiation source) in order to convert detector output into radiation intensity. To measure high temperatures, the detectors are chosen to be sensitive in the spectral range from 0.4 to 2.5 micrometers. A blackbody furnace equilibrated at around 1000 C is often used for this calibration. Though the detector may respond sensitively to short wavelengths radiation, a blackbody furnace at 1000 C emits only feebly at very short wavelengths. As a consequence, the calibration constants that result may not be the most accurate. For pyrometry calibration, a radiation source emitting strongly at the short wavelengths is preferred. We have chosen a quartz halogen lamp for this purpose.

Ng, Daniel↗

Cosmic Ray Energetics and Mass (CREAM)

The CREAM instrument was flown on a Long Duration Balloon in Antarctica in December 2004 and January 2005, achieving a flight duration record of nearly 42 days. It detected and recorded cosmic ray primary particles ranging in type from hydrogen to iron nuclei and in energy from 1 TeV to several hundred TeV. With the data collected we will have the world's best measurement of the energy spectra and mass composition of nuclei in the primary cosmic ray flux at these energies, close to the astrophysical knee . The instrument utilized a thin calorimeter, a transition radiation detector and a timing charge detector, which also provided time-of-flight information. The responsibilities of our group have been with the timing charge detector (TCD), and with the data acquisition electronics and ground station support equipment. The TCD utilized fast scintillators to measure the charge of the primary cosmic ray before any interactions could take place within the calorimeter. The data acquisition electronics handled the output of the various detectors, in a fashion fully integrated with the payload bus. A space-qualified flight computer controlled the acquisition, and was used for preliminary trigger information processing and decision making. Ground support equipment was used to monitor the health of the payload, acquire and archive the data transmitted to the ground, and to provide real-time control of the instrument in flight.

Coutu, Stephane↗

Design of High Resolution Soft X-Ray Microcalorimeters Using Magnetic Penetration Thermometers

We have designed high-resolution soft x-ray microcalorimeters using magnetic penetration thermometers (MPTs) in an array of pixels covering a total of 2 square centimeters to have a resolving power of 300 at energies around 300 eV. This performance is desirable for studying the soft x-ray background from the warm hot intergalactic medium. MPT devices have small sensor heat capacity and high responsivities, which makes them excellent detector technology for attempting to attain sub-eV resolution. We are investigating the feasibility of pixels with absorbers that are 625 x 625 square micrometers, up to 1 x 1 square millimeters in area and 0.35 micrometer thick and thinner. Our tests have shown that suspended gold absorbers 0.35 micrometers thick (RRR = 6.7) are feasible to fabricate. We modeled the thermal diffusion from such thin gold over the size of a 625 x 625 square micrometer absorber, and conclude that the effect of the thermalization on the resolution of a 300 eV photon is an additional approximately 0.2 eV FWHM of broadening. We discuss the thermal effects of small absorber attachment sterns on solid substrate, as well as considerations for multiplexed readout. We will present the progress we have made towards building and testing this soft x-ray detector.

Busch. Sarah↗

Mission Oriented Support and Theory (MOST) for MMS -- The Goddard Space Flight Center/University of California Los Angeles Interdisciplinary Science Program

The MOST IDS team was tasked with focusing on two general areas: The first was to participate with the Fast Plasma Investigation (FPI) team in the development of virtual detectors that model the instrument responses of the MMS FPI sensors. The virtual instruments can be 'flown through' both simulation data (from magnetohydrodynamic, hybrid, and kinetic simulations) and Cluster and THEMIS spacecraft data. The goal is to determine signatures of magnetic reconnection expected during the MMS mission. Such signatures can serve as triggers for selection of burst mode downloads. The chapter contributed by the FPI team covers that effort in detail and, therefore, most of that work has not been included here. The second area of emphasis, and the one detailed in this chapter, was to build on past and present knowledge of magnetic reconnection and its physical signatures. Below we describe intensive analyses of Cluster and THEMIS data together with theoretical models and simulations that delineate the plasma signatures that surround sites of reconnection, including the effects of turbulence as well as the detailed kinetic signatures that indicate proximity to reconnection sites. In particular, we point out that particles are energized in several regions, not only at the actual site of reconnection.

Goldstein, Melvyn L.↗

Laser Spiderweb Sensor Used with Portable Handheld Devices

A portable spectrometer, including a smart phone case storing a portable spectrometer, wherein the portable spectrometer includes a cavity; a source for emitting electromagnetic radiation that is directed on a sample in the cavity, wherein the electromagnetic radiation is reflected within the cavity to form multiple passes of the electromagnetic radiation through the sample; a detector for detecting the electromagnetic radiation after the electromagnetic radiation has made the multiple passes through the sample in the cavity, the detector outputting a signal in response to the detecting; and a device for communicating the signal to a smart phone, wherein the smart phone executes an application that performs a spectral analysis of the signal.

Scott, David C.↗

Terra MODIS Sees Solar Eclipses: Analysis of Reflective Solar Band Response at Multiple Radiance Levels

The MODIS imaging spectroradiometer instruments on-board NASA's Terra and Aqua satellites have 20 reflective solar bands (RSB) covering a wavelength range from 400 to 2200 nm. Radiance is calculated from processing raw signals with background, temperature, and electronic contamination corrected. Measured gain is calibrated with a fully Sunlit solar diffuser (SD) at a stable radiance level, considering a slowly changing SD reflectance degradation. These measurements provide time-dependent gain adjustment factors, and the calibration assumes a linear response for each band and detector. Hence, an analysis of the dependence on different radiance levels is warranted. The MODIS design has no mechanism for varying radiance levels, except for an attenuator screen. However, it has been in static configuration for Terra since mid-2003. An external source of radiance attenuation can be utilized during solar eclipse events, while maintaining high stability and accuracy of solar calibration standards. Due to its long mission lifetime, Terra has seen several Sun-Moon near-conjunction events when it coincides with the orbit path where the SD is directly illuminated. As of August 2020, we have identified 7 viable partial solar eclipses in the Terra mission data. We will discuss several results of our study, including comparison of measured SD signal to predicted radiance reduction based on a solar disk radiance model; nominal and outlier behavior as a function of bands, detectors, and mirror-sides; and comparison with other data sets. Our main conclusion from this study is that there is no notable correlation of detector-dependent trend with radiance level for most RSB bands.

Terra↗

High Sensitivity Long-Wavelength Infrared QWIP Focal Plane Array Based Instrument for Remote Sensing of Icy Satellites

GaAs based Quantum Well Infrared Photodetector (QWIP) technology has shown remarkable success in advancing low cost, highly uniform, high-operability, large format multi-color focal plane arrays. QWIPs afford greater flexibility than the usual extrinsically doped semiconductor IR detectors. The wavelength of the peak response and cutoff can be continuously tailored over a range wide enough to enable light detection at any wavelength range between 6 and 20 micron. The spectral band-width of these detectors can be tuned from narrow (Deltalambda/lambda is approximately 10%) to wide (Deltalambda/lambda is approximately 40%) allowing various applications. Furthermore, QWIPs offer low cost per pixel and highly uniform large format focal plane arrays due to mature GaAs/AlGaAs growth and processing technologies. The other advantages of GaAs/AlGaAs based QWIPS are higher yield, lower l/f noise and radiation hardness (1.5 Mrad). In this presentation, we will discuss our recent demonstrations of 640x512 pixel narrow-band, broad-band, multi-band focal plane arrays, and the current status of the development of 1024x1024 pixel long-wavelength infrared QWIP focal plane arrays.

Gunapala, S.↗