Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “data logging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

Respiratory Amplitude Guided 4-Dimensional Magnetic Resonance Imaging

Purpose: To evaluate the feasibility of prospectively guiding 4-dimensional (4D) magnetic resonance imaging (MRI) image acquisition using triggers at preselected respiratory amplitudes to achieve T{sub 2} weighting for abdominal motion tracking. Methods and Materials: A respiratory amplitude-based triggering system was developed and integrated into a commercial turbo spin echo MRI sequence. Initial feasibility tests were performed on healthy human study participants. Four respiratory states, the middle and the end of inhalation and exhalation, were used to trigger 4D MRI image acquisition of the liver. To achieve T{sub 2} weighting, the echo time and repetition time were set to 75 milliseconds and 4108 milliseconds, respectively. Single-shot acquisition, together with parallel imaging and partial k-space imaging techniques, was used to improve image acquisition efficiency. 4D MRI image sets composed of axial or sagittal slices were acquired. Results: Respiratory data measured and logged by the MRI scanner showed that the triggers occurred at the appropriate respiratory levels. Liver motion could be easily observed on both 4D MRI image datasets by sensing either the change of liver in size and shape (axial) or diaphragm motion (sagittal). Both 4D MRI image datasets were T{sub 2}-weighted as expected. Conclusions: This study demonstrated the feasibility of achieving T{sub 2}-weighted 4D MRI images using amplitude-based respiratory triggers. With the aid of the respiratory amplitude-based triggering system, the proposed method is compatible with most MRI sequences and therefore has the potential to improve tumor-tissue contrast in abdominal tumor motion imaging.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Numerical simulations of depressurization-induced gas production from gas hydrate reservoirs at the Walker Ridge 312 site, northern Gulf of Mexico

In 2009, the Gulf of Mexico (GOM) Gas Hydrates Joint-Industry-Project (JIP) Leg II drilling program confirmed that gas hydrate occurs at high saturations within reservoir-quality sands in the GOM. A comprehensive logging-while-drilling dataset was collected from seven wells at three sites, including two wells at the Walker Ridge 313 site. By constraining the saturations and thicknesses of hydrate-bearing sands using logging-while-drilling data, two-dimensional (2D), cylindrical, r-z and three-dimensional (3D) reservoir models were simulated. The gas hydrate occurrences inferred from seismic analysis are used to delineate the areal extent of the 3D reservoir models. Numerical simulations of gas production from the Walker Ridge reservoirs were conducted using the depressurization method at a constant bottomhole pressure. Results of these simulations indicate that these hydrate deposits are readily produced, owing to high intrinsic reservoir-quality and their proximity to the base of hydrate stability. The elevated in situ reservoir temperatures contribute to high (5–40 MMscf/day) predicted production rates. The production rates obtained from the 2D and 3D models are in close agreement. To evaluate the effect of spatial dimensions, the 2D reservoir domains were simulated at two outer radii. The results showed increased potential for formation of secondary hydrate and appearance of lag time for production rates as reservoir size increases. Similar phenomena were observed in the 3D reservoir models. The results also suggest that interbedded gas hydrate accumulations might be preferable targets for gas production in comparison with massive deposits. Hydrate in such accumulations can be readily dissociated due to heat supply from surrounding hydrate-free zones. Special cases were considered to evaluate the effect of overburden and underburden permeability on production. The obtained data show that production can be significantly degraded in comparison with a case using impermeable boundaries. The main reason for the reduced productivity is water influx from the surrounding strata; a secondary cause is gas escape into the overburden. The results dictate that in order to reliably estimate production potential, permeability of the surroundings has to be included in a model.

2D and 3D reservoir simulations↗

Permeability and porosity of hydrate-bearing sediments in the northern Gulf of Mexico

Hydrate-bearing sands are being actively explored because they contain the highest concentrations of hydrate and are the most economically recoverable hydrate resource. However, relatively little is known about the mechanisms or timescales of hydrate formation, which are related to methane supply, fluid flux, and host sediment properties such as permeability. We used logging-while-drilling data from locations in the northern Gulf of Mexico to develop an effective medium theory-based model for predicting permeability based on clay-sized sediment fraction. The model considers permeability varying between sand and clay endpoint permeabilities that are defined from laboratory data. We verified the model using permeability measurements on core samples from three boreholes, and then used the model to predict permeability in two wells drilled in Walker Ridge Block 313 during the Gulf of Mexico Gas Hydrate Joint Industry Project Leg II expedition in 2009. We found that the cleanest sands (clay-sized fraction <0.05) had intrinsic (hydrate-free) permeability contrasts of 5-6 orders of magnitude with the surrounding clays, which is sufficient to provide focused hydrate formation due to advection of methane from a deep source or diffusion of microbial methane from nearby clay layers. In sands where the clay-sized fraction exceeds 0.05, the permeability reduces significantly and focused flow is less pronounced. In these cases, diffusion of dissolved microbial methane is most likely the preferred mode of methane supply for hydrate formation. In conclusion, our results provide important constraints on methane supply mechanisms in the Walker Ridge area and have global implications for evaluating rates of methane migration and hydrate formation in hydrate-bearing sands.

58 GEOSCIENCES↗

India National Gas Hydrate Program Expedition 02 Summary of Scientific Results: Gas Hydrate Systems Along the Eastern Continental Margin of India

The India National Gas Hydrate Program Expedition 02 (NGHP-02) discovered gas hydrate at high saturation in sand reservoirs at several sites in the deepwater Bay of Bengal. To assess the potential response of those deposits to scientific depressurization experiments, comprehensive geologic models were constructed to enable numerical simulation for two sites. Both sites (NGHP-02-09 and NGHP-02-16) feature thick sequences of thinly-interbedded reservoir and non-reservoir facies at sub-seafloor depths less than 300m and sub-sea depths of 2400m or more. These settings pose significant challenges to current modeling capabilities. First, the thinly-interbedded reservoir architecture complicates the determination of basic reservoir parameters from both log and core data due to measurement resolution issues. Secondly, the fine scale variation in sediment properties imparts great contrasts in key parameters over very short distances, creating high gradients at multiple scales and varying orientations that necessitate careful design of high-definition simulation grids. Thirdly, the deposits include internal sources of water, as well as a range of complex boundary conditions, including variable permeability within the overlying mud-rich “seals,” that complicate reservoir depressurization. Lastly, because of the unique combination of great water depth and relatively shallow sub-seafloor depth: models designed to maximize the dissociation rate impose large pressure drawdowns on relatively low-strength sediments. This condition renders the proper evaluation and integration of the geomechanical response to hydrate dissociation critical. In this report, we review the history of gas hydrate reservoir simulation, discuss methods for creating geologic input models, and summarize the key findings and implications of the collaborative NGHP-02 numerical simulation effort. Together, the studies confirm the viability of the modeled accumulations for scientific testing and identify key challenges related to the selection of specific test sites and the design of test wells.

Collett, Tim↗

Specific absorbed fractions for a revised series of the UF/NCI pediatric reference phantoms: internal photon sources

Assessment of radiation absorbed dose to internal organs of the body from the intake of radionuclides, or in the medical setting through the injection of radiopharmaceuticals, is generally performed based upon reference biokinetic models or patient imaging data, respectively. Biokinetic models estimate the time course of activity localized to source organs. The time-integration of these organ activity profiles are then scaled by the radionuclide S-value, which defines the absorbed dose to a target tissue per nuclear transformation in various source tissues. S-values are computed using established nuclear decay information (particle energies and yields), and a parameter termed the specific absorbed fraction (SAF). The SAF is the ratio of the absorbed fraction—fraction of particle energy emitted in the source tissue that is deposited in the target tissue—and the target organ mass. While values of the SAF may be computed using patient-specific or individual-specific anatomic models, they have been more widely available through the use of computational reference phantoms. In this study, we report on an extensive series of photon SAFs computed in a revised series of the University of Florida and the National Cancer Institute pediatric reference phantoms which have been modified to conform to the specifications embodied in the ICRP reference adult phantoms of Publication 110 (e.g. organs modeled, organ ID numbers, blood contribution to elemental compositions). Following phantom anatomical revisions, photon radiation transport simulations were performed using MCNPX v2.7 in each of the ten phantoms of the series—male and female newborn, 1 year old, 5 year old, 10 year old, and 15 year old—for 60 different tissues serving as source and/or target regions. A total of 25 photon energies were considered from 10 keV to 10 MeV along a logarithm energy grid. Detailed analyses were conducted of the relative statistical errors in the Monte Carlo target tissue energy deposition tallies at low photon energies and over all energies for source–target combinations at large intra-organ separation distances. Based on these analyses, various data smoothing algorithms were employed, including multi-point weighted data smoothing, and log–log interpolation at low energies (1 keV and 5 keV) using limiting SAF values based upon target organ mass to bound the interpolation interval. The final dataset is provided in a series of ten electronic supplemental files in MS Excel format. Finally, the results of this study were further used as the basis for assessing the radiative component of internal electron source SAFs as described in our companion paper (Schwarz et al 2021) for this same pediatric phantom series.

61 RADIATION PROTECTION AND DOSIMETRY↗

Specific absorbed fractions for a revised series of the UF/NCI pediatric reference phantoms: internal electron sources

Assessment of radiation absorbed dose to internal organs of the body from the intake of radionuclides, or in the medical setting through the injection of radiopharmaceuticals, is generally performed based upon reference biokinetic models or patient imaging data, respectively. Biokinetic models estimate the time course of activity localized to source organs. The time-integration of these organ activity profiles are then scaled by the radionuclide S-value, which defines the absorbed dose to a target tissue per nuclear transformation in various source tissues. S-values are computed using established nuclear decay information (particle energies and yields), and a parameter termed the specific absorbed fraction (SAF). The SAF is the ratio of the absorbed fraction—fraction of particle energy emitted in the source tissue that is deposited in the target tissue—and the target organ mass. While values of the SAF may be computed using patient-specific or individual-specific anatomic models, they have been more widely available through the use of computational reference phantoms. In this study, we report on an extensive series of photon SAFs computed in a revised series of the University of Florida and the National Cancer Institute pediatric reference phantoms which have been modified to conform to the specifications embodied in the ICRP reference adult phantoms of Publication 110 (e.g. organs modeled, organ ID numbers, blood contribution to elemental compositions). Following phantom anatomical revisions, photon radiation transport simulations were performed using MCNPX v2.7 in each of the ten phantoms of the series—male and female newborn, 1 year old, 5 year old, 10 year old, and 15 year old—for 60 different tissues serving as source and/or target regions. A total of 25 photon energies were considered from 10 keV to 10 MeV along a logarithm energy grid. Detailed analyses were conducted of the relative statistical errors in the Monte Carlo target tissue energy deposition tallies at low photon energies and over all energies for source–target combinations at large intra-organ separation distances. Based on these analyses, various data smoothing algorithms were employed, including multi-point weighted data smoothing, and log–log interpolation at low energies (1 keV and 5 keV) using limiting SAF values based upon target organ mass to bound the interpolation interval. The final dataset is provided in a series of ten electronic supplemental files in MS Excel format. Finally, the results of this study were further used as the basis for assessing the radiative component of internal electron source SAFs as described in our companion paper (Schwarz et al 2021) for this same pediatric phantom series.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Optimizing the accuracy of a helical diode array dosimeter: A comprehensive calibration methodology coupled with a novel virtual inclinometer

Purpose: The goal of any dosimeter is to be as accurate as possible when measuring absolute dose to compare with calculated dose. This limits the uncertainties associated with the dosimeter itself and allows the task of dose QA to focus on detecting errors in the treatment planning (TPS) and/or delivery systems. This work introduces enhancements to the measurement accuracy of a 3D dosimeter comprised of a helical plane of diodes in a volumetric phantom. Methods: We describe the methods and derivations of new corrections that account for repetition rate dependence, intrinsic relative sensitivity per diode, field size dependence based on the dynamic field size determination, and positional correction. Required and described is an accurate ''virtual inclinometer'' algorithm. The system allows for calibrating the array directly against an ion chamber signal collected with high angular resolution. These enhancements are quantitatively validated using several strategies including ion chamber measurements taken using a ''blank'' plastic shell mimicking the actual phantom, and comparison to high resolution dose calculations for a variety of fields: static, simple arcs, and VMAT. A number of sophisticated treatment planning algorithms were benchmarked against ion chamber measurements for their ability to handle a large air cavity in the phantom. Results: Each calibration correction is quantified and presented vs its independent variable(s). The virtual inclinometer is validated by direct comparison to the gantry angle vs time data from machine log files. The effects of the calibration are quantified and improvements are seen in the dose agreement with the ion chamber reference measurements and with the TPS calculations. These improved agreements are a result of removing prior limitations and assumptions in the calibration methodology. Average gamma analysis passing rates for VMAT plans based on the AAPM TG-119 report are 98.4 and 93.3% for the 3%/3 mm and 2%/2 mm dose-error/distance to agreement threshold criteria, respectively, with the global dose-error normalization. With the local dose-error normalization, the average passing rates are reduced to 94.6 and 85.7% for the 3%/3 mm and 2%/2 mm criteria, respectively. Some algorithms in the convolution/superposition family are not sufficiently accurate in predicting the exit dose in the presence of a 15 cm diameter air cavity. Conclusions: Introduction of the improved calibration methodology, enabled by a robust virtual inclinometer algorithm, improves the accuracy of the dosimeter's absolute dose measurements. With our treatment planning and delivery chain, gamma analysis passing rates for the VMAT plans based on the AAPM TG-119 report are expected to be above 91% and average at about 95% level for {gamma}(3%/3 mm) with the local dose-error normalization. This stringent comparison methodology is more indicative of the true VMAT system commissioning accuracy compared to the often quoted dose-error normalization to a single high value.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Falcon: A Temporal Visual Analysis System

Flexible visible exploration of long, high-resolution time series from multiple sensor streams is a challenge in several domains. Falcon is a visual analytics approach that helps researchers acquire a deep understanding of patterns in log and imagery data. Falcon allows users to interactively explore large, time-oriented data sets from multiple linked perspectives. Falcon provides overviews, detailed views, and unique segmented time series visualizations with multiple levels of detail. These capabilities are applicable to the analysis of any quantitative time series.

Steed, ChadA.↗

RadTrac : A system for detecting, localizing, and tracking radioactive sources in real time.

Within the homeland security and emergency response communities, there is a need for a low-profile system to detect and locate radioactive sources. RadTrac has been developed at Argonne National Laboratory as an integrated system for the detection, localization, identification, and tracking of radioactive sources in real time. The system is based on a network of radiation detectors and advanced signal-processing algorithms. Features include video surveillance, automated tracking, easy setup, and logging of all data and images. This paper describes the advanced algorithms that were developed and implemented for source detection, localization, and tracking in real time. In the physio-spatial integration approach to source localization, counts from multiple detectors are processed according to the underlying physics linking these counts to obtain the probability that a source is present at any point in space. This information is depicted in a probability density function map. This type of depiction allows the results to be presented in a simple, easy-to-understand manner. It also allows for many different complicated factors to be accounted for in a single image as each factor is computed as a probability density in space. These factors include spatial limitations, variable shielding, directional detectors, moving detectors, and different detector sizes and orientations. The utility and versatility of this approach is described in further detail. Advanced signal-processing algorithms have also been incorporated to improve real-time tracking and to increase signal-to-noise ratios including temporal linking and energy binning. Measurements aimed at demonstrating the sensitivity improvements through the use of advanced signal-processing techniques were performed and are presented. Results of tracking weak sources (<100 {micro}Ci {sup 137}Cs) using four fixed-position detectors are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Utah FORGE: Documentation on Discrete Fracture Network and Fracture Propagation Modelling

This dataset includes reports and a slide presentation on discrete fracture network (DFN) generation and hydraulic fracture modeling at the Utah FORGE site. It details the characterization of natural fractures using well log and core data, as well as stochastic modeling techniques. The reports describe simulations of hydraulic fracture propagation, fluid-mechanical interactions, and induced microseismicity. The dataset also includes history-matching of net pressure and analyses of fracture growth in naturally fractured geothermal reservoirs. The slides summarize key findings and future research directions.

15 GEOTHERMAL ENERGY↗

Municipality of Anchorage Household Travel Survey

The 2002 Household Travel Survey for the municipality of Anchorage, Alaska, collected demographic, socioeconomic, and travel information about households and persons (age five and older) on an assigned, 24-hour travel period. The main objective of the study, conducted by NuStats, was to improve the transportation system. 2,035 households were recruited to participate in the study. Of these, 1,293 completed travel logs depicting detailed data on driving habits, such as purpose of the trips, time of the data, and mode of transportation—spanning from April 1, 2002, to May 17, 2002. This dataset is part of the Metropolitan Travel Survey Archive, which includes travel surveys from numerous public agencies across the United States and is archived by the Transportation Secure Data Center to ensure their continued public availability.

1Hz data↗

Moisture Metrics Project

This research added to the understanding of moisture, as it relates to the processing of grass biomass in a commercial setting. It added to the understanding by reinforcing the idea that each grass species has its own unique characteristics as it relates to moisture and processing. And while sometimes these results were not able to be measured according to the parameters of this test project, it was an attribute distinctly noticeable by the end of this project, and discovered by the equipment operators themselves. Key to this discovery was the fact that while a bale of grass may test at a specific moisture percentage with a handheld probe, the actual moisture content within the cell walls of the plant matter may vary significantly from that reading. This difference arises from the ability of some plant species to retain the moisture more within the cell walls, as opposed to other plant species simply holding the moisture on the outer surface of the stalks. This of course is coupled with the methodologies used by the individual landowner in the handling of the biomass, specifically, time of harvest and storage technique. However, it still comes down to different species retaining moisture in different ways according to their cell wall structure. While this may not seem significant, it is of critical importance when you combine that varying trait, with the “action” of processing it. The testing criteria initially established by this project, was in the end inadequate to document these traits thoroughly, and will require future, more detailed projects to adequately document it. The project approach, and the resulting data contained within this report, failed to give us the conclusive data we thought we would eventually arrive at when this project was completed. However, the efforts put forth by this project , and the lack of hard data using our approach, does enable future projects to have a much better understanding of how to approach this subject from a technical standpoint. We have learned that the study must go deeper initially, back to the acreage where the grass was grown, and must include all attributes and inputs beginning there. This data must be logged and correlated along the entire lifecycle of the biomass, from beginning to end, to enable us to fully understand how moisture and specific species of grasses interact when combined with the action of commercial processing.

09 BIOMASS FUELS↗

Performance Evaluation of Darshan 3.0.0 on the Cray XC30

Abstract—Darshan is a lightweight I/O characterization tool used to gather and summarize salient I/O workload statistics from HPC applications. Darshan was designed to minimize any possible perturbations of an application’s performance, leading it to be enabled by default on a number of production HPC systems. For each file accessed by a given application, Darshan records the count and types of I/O operations performed, histograms of access sizes, cumulative timers on the amount of time spent doing I/O, and other statistical data. This type of data has proved invaluable in understanding and improving the I/O performance of HPC applications. Darshan 3.0.0 is the new modularized version of the traditional Darshan library and file format, allowing users to easily add more in-depth I/O characterization data to Darshan logs. In this work we perform an empirical evaluation of Darshan 3.0.0 to ensure that it continues to meet performance expectations for broad deployment. In particular, we evaluate the imposed overhead on instrumented I/O operations, time taken to shut down and generate corresponding Darshan log files, and resultant log file sizes for different workloads. These performance results are compared to results of Darshan 2.3.0 on the Edison XC30 system at NERSC to determine whether the new version is lightweight enough to run full-time on production HPC systems. Our evaluation shows that Darshan has limited impact on application I/O performance and can fully generate a corresponding log file for most application workloads in under two seconds.

97 MATHEMATICS AND COMPUTING↗

Mechanisms for Methane Transport and Hydrate Accumulation in Coarse-Grained Reservoirs

The distribution of natural methane hydrate within high saturation reservoirs and mechanisms that control the migration of methane are an active area of research. In this project, we studied methane migration mechanisms and associated hydrate accumulation rates in coarse-grained sands of the Terrebonne Basin, located in Walker Ridge Block 313 (WR313), northern Gulf of Mexico. Hydrate in this area is distributed heterogeneously within ~900 m of methane hydrate stability zone, in both thick (10-25 m) and thin (< 3 m) sand layers, and in units of subvertical hydrate-filled fractures. We investigated hydrate formation from diffusively and advectively supplied methane using one-, two-, and three-dimensional basin modeling with inputs from well log and seismic data. The hydrate accumulations at WR313 can mostly be explained by short, diffusive migration of methane as well as short-range advective transport of methane from clays into neighboring coarser-grained layers. This is likely enhanced by small-scale lithologic variations, including local microbial methanogenesis in interbedded clays. Furthermore, our work shows overpressure in clay sediments surrounding sand reservoirs may enhance short-range diffusive migration. Long-range migration of dissolved methane and gas mainly influence hydrate saturation right at the base of the hydrate stability zone, although the dissolved phase can be channeled upwards along sands by compaction-driven flow. Capillary effects can allow gas bubbles to migrate appreciable distances above the predicted base of gas hydrate stability, possibly reaching a few tens of meters into the hydrate stability zone. Recycling methane from hydrate buried beneath the base of the hydrate stability zone can concentrate hydrate at large saturations within a few tens of meters of the base of hydrate stability.

58 GEOSCIENCES↗

Additively Manufactured Tamper Evident Container

Los Alamos National Laboratory has developed a revolutionary and reliable new tamper evident container (TEC) to monitor and protect the health, security, and distribution of high-value assets, technological advancements, products, materials and more that are critical to the operations of businesses and government organizations. Unlike traditional tamper evident seals, the entire TEC serves as a seal, with encrypted on-board electronics able to continuously monitor and log structural health data including but not limited to force, temperature, pressure, humidity, orientation, radiation, acceleration, or vibration as needed. Analog and encrypted digital boards safely stored inside the TEC permanently record the complete integrity history of the protected items and have the ability to alert the TEC owners or take immediate defensive actions should a disruptive or tamper event take place.

36 MATERIALS SCIENCE↗