Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “coverage”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

Daily Isocenter Correction With Electromagnetic-Based Localization Improves Target Coverage and Rectal Sparing During Prostate Radiotherapy

Purpose: To evaluate dosimetric consequences of daily isocenter correction during prostate cancer radiation therapy using the Calypso 4D localization system. Methods and Materials: Data were analyzed from 28 patients with electromagnetic transponders implanted in their prostates for daily target localization and tracking. Treatment planning isocenters were recorded based on the values of the vertical, longitudinal, and lateral axes. Isocenter location obtained via alignment with skin tattoos was compared with that obtained via the electromagnetic localization system. Daily isocenter shifts, based on the isocenter location differences between the two alignment methods in each spatial axis, were calculated for each patient over their entire course. The mean isocenter shifts were used to determine dosimetric consequences of treatment based on skin tattoo alignments alone. Results: The mean += SD of the percentages of treatment days with shifts beyond += 0.5 cm for vertical, longitudinal and lateral shifts were 62% += 28%, 35% += 26%, and 38% +=21%, respectively. If daily electromagnetic localization was not used, the excess in prescribed dose delivered to 70% of the rectum was 10 Gy and the deficit in prescribed dose delivered to 95% of the planning target volume was 10 Gy. The mean isocenter shift was not associated with the volumes of the prostate, rectum, or bladder, or with patient body mass index. Conclusions: Daily isocenter localization can reduce the treatment dose to the rectum. Correcting for this variability could lead to improved dose delivery, reduced side effects, and potentially improved treatment outcomes.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The degree of rate control of catalyst-bound intermediates in catalytic reaction mechanisms: Relationship to site coverage

The degree of rate control (DRC) quantifies how much the energy of each species in a reaction mechanism (e.g., catalyst-bound intermediates and transition states) affects the net reaction rate. It thus plays an important role in understanding catalyst activity and selectivity and in efforts to find better catalysts. We show here that under steady-state reaction conditions, the DRC for any catalyst-bound intermediate n ( X n ) is proportional to its fractional population of catalyst sites ( θ n ), X n = - σ × θ n , where the proportionality constant σ is given by σ = Σ i X i × n i . In this report, X i is the DRC of the transition state in step i , n i is the number of catalyst sites of the same type required for the elementary step i , and the sum is over all transition states (or elementary steps) i . While only a few transition states typically have non-negligible DRCs, this simple sum (or weighted average of elementary-step site requirements) includes only a few terms (and only one term when there is a single rate-determining step). We also show that the DRCs of reactants and catalyst depend upon the choice of zero-energy reference, but simplify to zero when their standard states are used as the zero-energy references.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

H 2 O-assisted O 2 reduction by H 2 on Pt and PtAu bimetallic nanoparticles: Influences of composition and reactant coverages on kinetic regimes, rates, and selectivities

Hydrogen peroxide (H 2 O 2 ) can replace hazardous oxidants in industrial processes but is currently too expensive for many such applications. While direct synthesis of H 2 O 2 (H 2 + O 2 → H 2 O 2 ) may reduce costs in comparison to incumbent technology, current catalysts lack the requisite stability and selectivity. Here, we examine the direct synthesis of H 2 O 2 on bimetallic Pt 1 Au x (0 ≤ x ≤ 230) and Pt catalysts at steady-state in pure water and relate kinetic parameters for H 2 O 2 and H 2 O formation to possible active site structures informed by complementary characterization methods. X-ray photoelectron spectra show significant Pt surface enrichment compared to the bulk composition. Analysis of infrared spectra of mixed monolayers of 12 CO* and 13 CO* indicate that Pt and Au form substitutional surface alloys. The Pt 1 Au x nanoparticles with the greatest mole fractions of Au predominantly expose Pt monomers (i.e., isolated Pt atoms), yet Pt atoms exposed upon all these nanoparticles possess electronic structures distinct from bulk Pt. Despite these differences, rate measurements are consistent with product formation through proton-electron transfer pathways for all Pt 1 Au x catalysts. In situ XAS indicate that Pt remains metallic during H 2 O 2 synthesis. Under the most oxidizing conditions, selectivities toward H 2 O 2 increase strongly with the Au to Pt ratio from 2% for monometallic Pt to 85% for Pt 1 Au 170 . However, selectivities are similar among all catalysts within reducing conditions. Comparisons of apparent activation enthalpies for the formation of H 2 O 2 and H 2 O across these catalysts and the range of conditions suggest that Pt monomers within Au provide the greatest selectivities for H 2 O 2 formation, because these active sites present high barriers for O-O bond rupture. Further, selectivities decrease with increasing ratios of H 2 to O 2 pressures, because Pt atoms aggregate and form oligomers that readily dissociate dioxygen intermediates. The combined use of spectroscopy, kinetics, and concepts employed in reaching these conclusions take inspiration from the legacy of Prof. Michel Boudart, and specifically his elegant methods for interrogating bimetallic catalysts.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Mechanical characterization of 304L-VAR stainless steel in tension with a full coverage of low, intermediate, and high strain rates

A 304L-VAR stainless steel is mechanically characterized in tension over a full range of strain rates from low, intermediate, to high using a variety of apparatuses. While low- and high-strain-rate tests are conducted with a conventional Instron and a Kolsky tension bar, the tensile tests at intermediate strain rates are conducted with a fast MTS and a Drop-Hopkinson bar. The fast MTS used in this study is able to obtain reliable tensile response at the strain rates up to 150 s -1 , whereas the lower limit for the Drop-Hopkinson bar is 100 s -1 . Combining the fast MTS and the Drop-Hopkinson bar closes the gap within the intermediate strain rate regime. Using these four apparatuses, the tensile stress-strain curves of the 304L-VAR stainless steel are obtained at strain rates on each order of magnitude ranging from 0.0001 to 2580 s -1 . All tensile stress-strain curves exhibit linear elasticity followed by significant work hardening prior to necking. After necking occurrs, the specimen load decreases, and the deformation becomes highly localized until fracture. The tensile stress-strain response of the 304L-VAR stainless steel exhibits strain rate dependence. The flow stress increases with increasing strain rate and is described with a power law. The strain-rate sensitivity is also strain-dependent, possibly due to thermosoftening caused by adiabatic heating at high strain rates. The 304L-VAR stainless steel shows significant ductility. The true strains at the onset of necking and at failure are determined. The results show that the true strains at both onset of necking and failure decrease with increasing strain rate. The true failure strains are approximately 200% at low strain rates but are significantly lower (~100%) at high strain rates. The transition of true failure strain occurs within the intermediate strain rate range between 10 -2 and 10 2 s -1 . A Boltzmann description is used to present the effect of nominal strain rate on true failure strain.

304L-VAR stainless Steel↗

Effect of lung and target density on small-field dose coverage and PTV definition

We have studied the effect of target and lung density on block margin for small stereotactic body radiotherapy (SBRT) targets. A phantom (50 × 50 × 50 cm{sup 3}) was created in the Pinnacle (V9.2) planning system with a 23-cm diameter lung region of interest insert. Diameter targets of 1.6, 2.0, 3.0, and 4.0 cm were placed in the lung region of interest and centered at a physical depth of 15 cm. Target densities evaluated were 0.1 to 1.0 g/cm{sup 3}, whereas the surrounding lung density was varied between 0.05 and 0.6 g/cm{sup 3}. A dose of 100 cGy was delivered to the isocenter via a single 6-MV field, and the ratio of the average dose to points defining the lateral edges of the target to the isocenter dose was recorded for each combination. Field margins were varied from none to 1.5 cm in 0.25-cm steps. Data obtained in the phantom study were used to predict planning treatment volume (PTV) margins that would match the clinical PTV and isodose prescription for a clinical set of 39 SBRT cases. The average internal target volume (ITV) density was 0.73 ± 0.17, average local lung density was 0.33 ± 0.16, and average ITV diameter was 2.16 ± 0.8 cm. The phantom results initially underpredicted PTV margins by 0.35 cm. With this offset included in the model, the ratio of predicted-to-clinical PTVs was 1.05 ± 0.32. For a given target and lung density, it was found that treatment margin was insensitive to target diameter, except for the smallest (1.6-cm diameter) target, for which the treatment margin was more sensitive to density changes than the larger targets. We have developed a graphical relationship for block margin as a function of target and lung density, which should save time in the planning phase by shortening the design of PTV margins that can satisfy Radiation Therapy Oncology Group mandated treatment volume ratios.

61 RADIATION PROTECTION AND DOSIMETRY↗

First-principles study of sulfur passivation of GaP(001) surfaces at one-monolayer coverage

Using first-principles total energy method, we have studied the structural and electronic properties of Ga- and P-terminated GaP(001)(1×2) surfaces adsorbed with one monolayer of sulfur. It was found that the sulfur atoms prefer to occupy bridge sites and the periodicity becomes (1 × 1) on both Ga- and Pterminated surfaces. The S–Ga bond was confirmed to be stronger than the S–P bond. The electronic analysis showed that the surface state within the energy gap on the Ga-terminated GaP surface was noticeably reduced by the sulfur adsorption, while such reduction does not occur on the P-terminated surface due to the S–P antibonding state. The nearly filled S dangling bonds on the Ga-terminated surface make this surface resistant to contamination.

36 MATERIALS SCIENCE↗

Expanding Coverage of the Metabolome for Global Metabolite Profiling

Mass spectrometry-based metabolomics is the comprehensive study of naturally occurring small molecules collectively known as the metabolome. Given the vast structural diversity and chemical properties of endogenous metabolites, biological extraction and chromatography methods bias the number, property, and concentration of metabolites detected by mass spectrometry and creates a challenge for global untargeted studies. In this work, we used Escherichia coli bacterial cells to explore the influence of solvent polarity, temperature, and pH in extracting polar and nonpolar metabolites simultaneously. In addition, we explored chromatographic conditions involving different stationary and mobile phases that optimize the separation and ionization of endogenous metabolite extracts as well as a mixture of synthetic standards. Our results reveal that hot polar solvents are the most efficient in extracting both hydrophilic and hydrophobic metabolites simultaneously. In addition, ammonium fluoride in the mobile phase substantially improved ionization efficiency in negative electrospray ionization mode by an average increase in signal intensity of 5.7 and over a 2-fold increase in the total number of features detected. The improvement in sensitivity with ammonium fluoride resulted in 3.5 times as many metabolite hits in databases compared to ammonium acetate or formic acid enriched mobile phases and allowed for the identification of unique metabolites involved in fundamental cellular pathways.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗