Advanced passive radiator for spaceborne cryogenic cooling

A novel design to improve the cooling capability of spaceborne cryogenic passive radiators is described. The design is based on the use of lightweight angled radiation shields, low-conductance structural supports, and a separate detachable launch-support system to reduce the parasitic heat leaks from the warm spacecraft to the cold radiator. The effectiveness of this design is demonstrated by thermal-vacuum-chamber experiments which indicate that the angled-radiation-shield assembly has an effective emittance that is an order of magnitude lower than that of the best multilayer insulation used in flight. Performance predictions based on the experiments and analytical model indicate that an advanced passive-radiator design based on this technology would be between 10 and 57% of the size and 10 and 36% of the mass of the best state-of-the-art passive radiators and would make lower temperatures (< 60 K) and larger heat loads practical. The cooling requirements of many new spaceborne instruments could be accommodated by application of this new passive-radiator design.

Steven Bard↗

Evaluation of thermostat location for multizone commercial building performance

In multi-zone buildings, it is often found that a single shared thermostat controls more than one conditioned zones. Although these shared zones are supposed to have similar thermal needs (e.g., cooling and heating load), in reality, they are not mainly due to different orientations, sizes of windows, occupancy, space types, etc. This can cause unnecessary energy waste or thermal discomfort for the occupants. How to quantify this impact in multizone buildings remains a research gap. Therefore, this study aims to evaluate the impact of different sensor (i.e., thermostat) locations for multizone commercial buildings through a comprehensive modeling study. Here, two different scenarios for the sensor locations were selected to evaluate the impact in terms of energy and thermal comfort. The scenario (1) is that one to five sensors distributed among the five zones, but the sensor readings from selected zones will be used for no-sensor zones, which is no-mean sensor scenario. The scenario (2) is that one to five sensors distributed among the five zones, but the average temperature from the shared zones will be used for each of the shared zones, which is a mean sensor scenario. The uncertainty analysis was performed for different sensor location scenarios.(a)The major findings from an energy perspective, for scenario (1), the differences of cooling energy go as high as 17% more or 12% less, compared with the baseline. For heating energy consumption, the discrepancies go as high as 51% more or 52% less, compared with baseline. For site energy consumption, the discrepancies go as high as 3.2% more or 3.2% less, compared with baseline. For fan energy consumption, the discrepancies go as high as 3.2% more or as low as 1.0% less, compared with baseline. For scenario (2), the discrepancies of cooling energy go as high as 3% more, or 0.5% less, compared with the baseline. For heating energy consumption, the discrepancies, are go as high as 10.1% more or as low as 3.0% less, compared with baseline. For site energy consumption, the discrepancies go as high as 1.3% more or 0.3% less, compared with baseline. For fan energy consumption, the discrepancies go as high as 3.1% more or as low as 1.0% less, compared with baseline.(b) In terms of the indoor thermal comfort, for the no-mean-sensor scenarios, the discrepancies of unmet hours for cooling mode can be as high as 1,200 h, compared with the baseline. The discrepancies of unmet hours for heating mode can be as high as 740 h, compared with the baseline. For the mean-sensor scenarios, the discrepancies of unmet hours for cooling mode can be as high as 750 h, compared with the baseline. The discrepancies of unmet hours for heating mode can be as high as 50 h, compared with the baseline.

42 ENGINEERING↗

Climate Control Load Reduction Strategies for Electric Drive Vehicles in Warm Weather

Passenger compartment climate control is one of the largest auxiliary loads on a vehicle. Like conventional vehicles, electric vehicles (EVs) require climate control to maintain occupant comfort and safety, but cabin heating and air conditioning have a negative impact on driving range for all electric vehicles. Range reduction caused by climate control and other factors is a barrier to widespread adoption of EVs. Reducing the thermal loads on the climate control system will extend driving range, thereby reducing consumer range anxiety and increasing the market penetration of EVs. Researchers at the National Renewable Energy Laboratory have investigated strategies for vehicle climate control load reduction, with special attention toward EVs. Outdoor vehicle thermal testing was conducted on two 2012 Ford Focus Electric vehicles to evaluate thermal management strategies for warm weather, including solar load reduction and cabin pre-ventilation. An advanced thermal test manikin was used to assess a zonal approach to climate control. In addition, vehicle thermal analysis was used to support testing by exploring thermal load reduction strategies, evaluating occupant thermal comfort, and calculating EV range impacts. Through stationary cooling tests and vehicle simulations, a zonal cooling configuration demonstrated range improvement of 6%-15%, depending on the drive cycle. A combined cooling configuration that incorporated thermal load reduction and zonal cooling strategies showed up to 33% improvement in EV range.

33 ADVANCED PROPULSION SYSTEMS↗

A New Multi-Method Assessment of Stratospheric Sulfur Load From the Okmok II Caldera-Forming Eruption of 43 BCE

The 43 BCE eruption of Okmok Volcano has been proposed to have had a significant climate cooling impact in the Northern Hemisphere. In this study, we quantify the climate cooling potential of the Okmok II eruption by measuring sulfur concentration in melt inclusions (up to 1,606 ppm) and matrix glasses and estimate a total of 62 ± 16 Tg S released. The proportion reaching the stratosphere (2.5%–25%, i.e., 1.5–15.5 Tg S) was constrained by physical modeling of the caldera-collapse eruption. Using the NASA Goddard Institute for Space Studies E2.2 climate model we found a linear response between cooling and stratospheric sulfur load (0.05–0.08°C/Tg S). Thus, the 1–2°C of cooling derived from proxy records would require 16–32 Tg sulfur injection. This study underscores the importance of combining approaches to estimate stratospheric S load. For Okmok II, we find all methods are consistent with a range of 15–16 Tg S.

volcano-climate interaction↗

Automatic generation and simulation of urban building energy models based on city datasets for city-scale building retrofit analysis

Buildings in cities consume 30–70% of total primary energy, and improving building energy efficiency is one of the key strategies towards sustainable urbanization. Urban building energy models (UBEM) can support city managers to evaluate and prioritize energy conservation measures (ECMs) for investment and the design of incentive and rebate programs. This paper presents the retrofit analysis feature of City Building Energy Saver (CityBES) to automatically generate and simulate UBEM using EnergyPlus based on cities’ building datasets and user-selected ECMs. CityBES is a new open web-based tool to support city-scale building energy efficiency strategic plans and programs. The technical details of using CityBES for UBEM generation and simulation are introduced, including the workflow, key assumptions, and major databases. Also presented is a case study that analyzes the potential retrofit energy use and energy cost savings of five individual ECMs and two measure packages for 940 office and retail buildings in six city districts in northeast San Francisco, United States. The results show that: (1) all five measures together can save 23–38% of site energy per building; (2) replacing lighting with light-emitting diode lamps and adding air economizers to existing heating, ventilation and air-conditioning (HVAC) systems are most cost-effective with an average payback of 2.0 and 4.3 years, respectively; and (3) it is not economical to upgrade HVAC systems or replace windows in San Francisco due to the city's mild climate and minimal cooling and heating loads. Furthermore, the CityBES retrofit analysis feature does not require users to have deep knowledge of building systems or technologies for the generation and simulation of building energy models, which helps overcome major technical barriers for city managers and their consultants to adopt UBEM.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Investigating the stability of reoriented hydrides and their reprecipitation using in-situ heating experiments

The behavior of radial hydrides in Zr-2.5Nb pressure tube samples at elevated temperature has been studied. The aim of this work is to investigate the stability of stress-reoriented hydrides under heating without an external applied load. Using in-situ heating at beamline, 1-ID at Argonne National Laboratory, USA, it was shown that two populations of hydrides existed in the sample, naturally oriented and reoriented hydrides. At a relatively low temperature of 180 °C it was observed that the reoriented hydrides completely dissolved, leaving only the naturally oriented hydrides in the sample, when heated without an applied load. On subsequent cooling of the sample, only naturally oriented hydrides were observed. These observations were confirmed using in-situ scanning electron microscopy heating experiments and post-mortem transmission electron microscopy studies. The results presented here offer a potential route for ductility recovery of pressure tube materials where radial hydrides have been shown to significantly reduce fracture toughness of components.

36 MATERIALS SCIENCE↗

Design and Modeling of Vacuum Pumping for Steady-State Pellet Fueling Systems

We report that future long-pulse magnetic confinement fusion reactors will require density and isotopic mixture control using steady-state repeating pellet injectors. For high-energy density burning plasmas, pellet velocities of 1 km/s and above will be required for sufficient plasma penetration to achieve high fueling efficiency. Currently, steady-state repeating injection systems utilize cryogenic extruder systems to produce an extrusion of solid deuterium or deuterium-tritium. In repeating light gas gun injectors, the solid extrusion is cut and simultaneously loaded into a barrel. Once loaded, a fast operating gas valve delivers a high pressure burst of gas to accelerate the pellet down the barrel and into the machine. This process takes ~10 ms to achieve. Adequate gas pumping of the extruder exhaust and injection line propellant gas collection chambers is necessary for optimal operation of the pellet fueling system. Excess solid from the extruder sublimates in an exhaust chamber. The gas pressure in the extruder exhaust chamber must remain low to maintain low heating loads on the cooling mechanism (cryorefrigerators or liquid helium flow) and to reduce thermal conduction to the extrusion. Pumping the injection line chambers is necessary to limit propellant gas flow into the machine. A numerical simulation code was created to predict temporal pumping performance for these repeating pellet injection systems. Lastly, this paper outlines the methods and assumptions used to create this model and compares results to the pellet injection system currently employed on DIII-D, the steady-state pellet injection system planned for the Wendelstein 7-X, and a brief analysis of the ITER conceptual pellet fueling system.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

DYNAMIC S0 GALAXIES: A CASE STUDY OF NGC 5866

S0 galaxies are often thought to be passively evolved from spirals after star formation is quenched. To explore what is actually occurring in such galaxies, we present a multi-wavelength case study of NGC 5866-a nearby edge-on S0 galaxy in a relatively isolated environment. This study shows strong evidence for dynamic activities in the interstellar medium, which are most likely driven by supernova explosions in the galactic disk and bulge. Understanding these activities can have strong implications for studying the evolution of such galaxies. We utilize Chandra, Hubble Space Telescope, and Spitzer data as well as ground-based observations to characterize the content, structure, and physical state of the medium and its interplay with the stellar component in NGC 5866. A cold gas disk is detected with an exponential scale height of approx10{sup 2} pc. Numerous distinct off-disk dusty spurs are also clearly present: prominent ones can extend as far as approx3 x 10{sup 2} pc from the galactic plane and are probably produced by individual SNe, whereas faint filaments can have approxkpc scale and are likely produced by SNe collectively in the disk/bulge. We also detect substantial amounts of diffuse Halpha- and Palpha-emitting gas with a comparable scale height as the cold gas. We find that the heating of the dust and warm ionized gas cannot be explained by the radiation from evolved stars alone, strongly indicating the presence of young stars in the galactic disk, though at a slow formation rate of approx0.05 M{sub sun} yr{sup -1}. We further reveal the presence of diffuse X-ray-emitting hot gas, which extends as far as 3.5 kpc away from the galactic plane and can be heated easily by Type Ia SNe in the bulge. However, the mean temperature of this gas is approx0.2 keV, substantially lower than what might be expected from the mass loss of evolved stars and Type Ia SNe heating alone in the galaxy, indicating that the mass loading from the cool gas is important. The total masses of the cold, warm ionized, and hot gases are approx5 x 10{sup 8} M{sub sun}, 4 x 10{sup 4} M{sub sun}, and 3 x 10{sup 7} M{sub sun}, respectively. The relative richness of the gases, apparently undergoing circulations between the disk and halo of the galaxy, is perhaps a result of its relative isolation.

79 ASTRONOMY AND ASTROPHYSICS↗

Hyperfine spectroscopy and laser cooling of the fermionic isotopes 47 Ti and 49 Ti

Here, we report on magneto-optical trapping of the two fermionic isotopes of atomic titanium, 47 Ti and 49 Ti . Unlike the even mass-number isotopes, which were recently laser cooled, 47 Ti and 49 Ti have nonzero nuclear spins and, consequently, their atomic levels are split by hyperfine structure. Combining and comparing theoretical calculations and atomic beam-spectroscopy measurements, we determine the hyperfine structures and isotope shifts of the 3⁢𝑑 2 ⁢4⁢𝑠 2 𝑎 3 ⁢𝐹 4 → 3⁢𝑑 2 ⁢( 3 𝑃)⁢4⁢𝑠⁢4⁢𝑝⁢( 3 𝑃 𝑜 ) 𝑦 5 ⁢𝐷$^o_4$ optical-pumping transition at optical wavelength 391 nm and the 3⁢𝑑 3 ⁢(4𝐹)⁢4⁢𝑠 𝑎 5 ⁢𝐹 5 → 3⁢𝑑 3 ⁢( 4 𝐹)⁢4⁢𝑝 𝑦 5 ⁢𝐺$^𝑜_6$ laser-cooling transition at wavelength 498 nm. With this information, we produce magneto-optical traps of both 47 Ti and 49 Ti by applying two additional tones of light to repump atoms to the maximum-spin states on the laser-cooling transition. Directly loading from the atomic flux of a titanium sublimation pump, we produce 47 Ti and 49 Ti traps with 731(190) and 1142(240) atoms, and with lifetimes of 330⁢(15) and 310⁢(8)⁢ ms, respectively.

atomic spectra↗

Cold collisions of PH ({sup 3}{Sigma}{sup -}) with helium in magnetic fields

A theoretical investigation of the He-PH ({sup 3}{Sigma}{sup -}) complex is presented. We perform ab initio calculations of the interaction potential energy surface and discuss its error bounds with relevance to cold collisions, and we carry out accurate calculations of bound energy levels of the complex including the molecular fine structure and magnetic-field effect. We find the potential has two shallow minima and supports ten and 13 bound levels in complex with {sup 3}He and {sup 4}He, respectively. Based on the potential the quantum scattering calculations are then implemented for elastic and inelastic cross sections of the magnetically trappable low-field-seeking state of PH ({sup 3}{Sigma}{sup -}) in collision with {sup 3}He atom. The cold-collision properties and the influence of the external magnetic field as well as the effect of the uncertainty of interaction potential on the collisionally induced Zeeman relaxation are explored and discussed in detail. The ratio of elastic to inelastic cross sections is large over a wide range of collision energy, magnetic field, and scaling factor of the potential, so that helium buffer-gas loading and evaporative cooling of PH is a good prospect.

74 ATOMIC AND MOLECULAR PHYSICS↗

Thermal behavior of single-crystal scintillators for high-speed X-ray imaging

Indirect detection of X-rays using single-crystal scintillators is a common approach for high-resolution X-ray imaging. With the high X-ray flux available from synchrotron sources and recent advances in high-speed visible-light cameras, these measurements are increasingly used to obtain time-resolved images of dynamic phenomena. The X-ray flux on the scintillator must, in many cases, be limited to avoid thermal damage and failure of the scintillator, which in turn limits the obtainable light levels from the scintillator. In this study, a transient one-dimensional numerical simulation of the temperature and stresses within three common scintillator crystals (YAG, LuAG and LSO) used for high-speed X-ray imaging is presented. Various conditions of thermal loading and convective cooling are also presented.

36 MATERIALS SCIENCE↗

Supervisory Feed-Forward Control for Real-Time Topping Cycle CHP Operation

This paper presents an energy dispatch algorithm for real-time topping cycle Cooling, Heating, and Power (CHP) operation for buildings with the objective of minimizing the operational cost, primary energy consumption (PEC), or carbon dioxide emission (CDE). The algorithm features a supervisory feed-forward control for real-time CHP operation using short-term weather forecasting. The advantages of the proposed control scheme for CHP operation are (a) relatively simple and efficient implementation allowing realistic real-time operation , (b) optimized CHP operation with respect to operational cost, PEC, or CDE, and (c) increased site-energy consumption (SEC) resulting in less dependence on the electric grid. In the feed-forward portion of the control scheme, short-term electric, cooling, and heating loads are predicted using the U.S. Department of Energy (DOE) benchmark small office building model. The results are encouraging regarding the potential saving of operational cost, PEC, and CDE from using the control system for a CHP system with electric and thermal energy storages.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Dynamic Facade Dashboard v0.1.0

The dashboard is a useful tool for early-stage building design decision-making and communication, as it can help users quickly compare the energy and non-energy related performance of various automated, integrated facade systems using a library of pre-computed data. Users can explore the impacts of various design choices by selecting different facade glazing and shading systems, facade control strategies, and lighting control strategies across multiple climate zones. The dashboard instantly visualizes key metrics, including energy usage in HVAC and lighting, peak cooling and heating load, and daylight availability, allowing immediate trade-off analysis to optimize building efficiency and comfort.

Yu, Tammie [Lawrence Berkeley National Laboratory ↗

Heat Pump Water Heater Ducting Strategies with Encapsulated Attics in Climate Zones 2 and 4

The focus of this study is on the performance of HPWHs with several different duct configurations and their effects on whole building heating, cooling, and moisture loads. A.O. Smith 60 gallon Voltex (PHPT-60) heat pump water heaters (HPWHs) were included at two project sites and ducted to or located within spray foamed encapsulated attics. The effect of ducting a HPWH's air stream does not diminish its efficiency if the ducting does not reduce intake air temperature, which expands HPWH application to confined areas. Exhaust ducts should be insulated to avoid condensation on the exterior, however this imposes a risk of condensation occurring in the duct's interior near the HPWH due to large variation of temperatures between the compressor and the duct and the presence of bulk moisture around the condenser. The HPWH's air conditioning impact on HVAC equipment loads is minimal when the intake and exhaust air streams are connected to a sealed attic and not the living space. A HPWH is not suitable as a replacement dehumidifier in sealed attics as peak moisture loads were observed to only be reduced if the heat pump operated during the morning. It appears that the intake air temperature and humidity was the most dominant variable affecting HPWH performance. Different ducting strategies such as exhaust duct only, intake duct only, and exhaust and intake ducting did not have any effect on HPWH performance.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Heat Pump Water Heater Ducting Strategies with Encapsulated Attics in Climate Zones 2 and 4

The focus of this study is on the performance of HPWHs with several different duct configurations and their effects on whole building heating, cooling, and moisture loads. A.O. Smith 60 gallon Voltex (PHPT-60) heat pump water heaters (HPWHs) were included at two project sites and ducted to or located within spray foamed encapsulated attics. The effect of ducting a HPWH's air stream does not diminish its efficiency if the ducting does not reduce intake air temperature, which expands HPWH application to confined areas.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Human Health Science Building Geothermal Heat Pump Systems

The grant objectives of the DOE grant funded project have been successfully completed. The Human Health Building (HHB) was constructed and opened for occupancy for the Fall 2012 semester of Oakland University. As with any large construction project, some issues arose which all were overcome to deliver the project on budget and on time. The facility design is a geothermal / solar-thermal hybrid building utilizing both desiccant dehumidification and variable refrigerant flow heat pumps. It is a cooling dominant building with a 400 ton cooling design day load, and 150 ton heating load on a design day. A 256 vertical borehole (320 ft depth) ground source heat pump array is located south of the building under the existing parking lot. The temperature swing and performance over 2013 through 2015 shows the ground loop is well sized, and may even have excess capacity for a future building to the north (planned lab facility). The HHB achieve a US Green Building Counsel LEED Platinum rating by collecting 52 of the total 69 available LEED points for the New Construction v.2 scoring checklist. Being Oakland's first geothermal project, we were very pleased with the building outcome and performance with the energy consumption approximately 1/2 of the campus average facility, on a square foot basis.

15 GEOTHERMAL ENERGY↗

High-Performance Integrated Window and Façade Solutions for California

The researchers developed a new generation of high-performance façade systems and supporting design and management tools to support industry in meeting California’s greenhouse gas reduction targets, reduce energy consumption, and enable an adaptable response to minimize real-time demands on the electricity grid. The project resulted in five outcomes: (1) The research team developed an R-5, 1-inch thick, triplepane, insulating glass unit with a novel low-conductance aluminum frame. This technology can help significantly reduce residential cooling and heating loads, particularly during the evening. (2) The team developed a prototype of a windowintegrated local ventilation and energy recovery device that provides clean, dry fresh air through the façade with minimal energy requirements. (3) A daylight-redirecting louver system was prototyped to redirect sunlight 15–40 feet from the window. Simulations estimated that lighting energy use could be reduced by 35–54 percent without glare. (4) A control system incorporating physics-based equations and a mathematical solver was prototyped and field tested to demonstrate feasibility. Simulations estimated that total electricity costs could be reduced by 9-28 percent on sunny summer days through adaptive control of operable shading and daylighting components and the thermostat compared to state-of-the-art automatic façade controls in commercial building perimeter zones. (5) Supporting models and tools needed by industry for technology R&D and market transformation activities were validated. Attaining California’s clean energy goals require making a fundamental shift from today’s ad-hoc assemblages of static components to turnkey, intelligent, responsive, integrated building façade systems. These systems offered significant reductions in energy use, peak demand, and operating cost in California.

24 POWER TRANSMISSION AND DISTRIBUTION↗