Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “control simulation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

Model Predictive Control for a Grid-interactive Efficient Thermal Storage-integrated Heat Pump System

Building heating and cooling systems can be used to overcome the mismatch between the intermittent supply of renewable power and the fluctuating demand for electricity. A novel underground thermal energy storage integrated with a dual-source heat pump has been proposed to mitigate the mismatch while meeting the thermal demand of buildings efficiently. Conventional thermostat control with heuristic rules cannot provide intelligent decisions to maximize the thermal efficiency and flexibility of the proposed system. Advanced control strategies like model predictive control (MPC) have provided a new paradigm for grid-interactive efficient building operation with the advancement of computation and sensing. This study developed an MPC for the proposed system to provide grid service for Demand Side Management and minimize the operating cost of building owners. A control-oriented dynamic model of the proposed system has been developed. Given an objective function and proper constraints, an optimization problem is formulated to determine the optimal control strategy of the system. Dynamic Programming is adopted to solve the optimization problem. A rule-based control (RBC) is also developed to achieve similar goals. Short-term simulations are conducted to compare the system performance resulting from the two controls. The simulation results indicate that the MPC performs more intelligently than the RBC in charging thermal energy storage and selecting heat pump sources by taking advantage of the predicted cooling demands of the building and the performance of the integrated system. As a result, the MPC could save energy and reduce operating costs compared with the RBC. A case study shows that, for a 3-day operation, the MPC saves 36.9% energy and reduces 38.5% operating cost compared with the RBC.

Shi, Liang↗

A Discrete Event Simulation Approach to Nuclear Arms Enterprise Modeling and Analysis

We overview a discrete event simulation of an arms control enterprise developed to familiarize individuals with the challenges of verification and monitoring at the enterprise level. We will review the design of the simulation applied to a notional country’s nuclear arms enterprise. This simulation models how these nuclear weapons move over their lifetime from deployment, storage, maintenance, and dismantlement. With this output information, we then characterize the “ground truth” of the enterprise. Next, based on these data, we built a sophisticated analysis engine designed to provide treaty monitoring and verification information to support partner country inspectors and their evaluation. This tool was designed to be used as a game, enabling teams to compete on developing the best inspection plan to determine if the host country is complying with the conceptual treaty developed for this effort.

Pulliam, Rachel M.↗

Exploring 2D X-ray diffraction phase fraction analysis with convolutional neural networks: Insights from kinematic-diffraction simulations

Abstract Deep-learning models are effective for analyzing the complex information in 2D X-ray diffraction (XRD) patterns. Accurately collecting parameters of the material sample is crucial during model training, significantly impacting model performance. In this study, we employ a kinematic-diffraction simulator to generate simulated 2D XRD patterns for Ti–6Al–4V alloy, allowing precise control of sample parameters. These simulated patterns are used to train convolutional neural networks, predicting $$\upbeta$$ β -phase volume fractions. The training data set consists exclusively of 2D XRD patterns with pure $$\upalpha$$ α - or pure $$\upbeta$$ β -phase, while the testing set incorporates patterns with intermediate phase volume fraction. In particular, we investigate how the architectures of the model influence prediction reliability and computational performance. Experimental results reveal that, with appropriate training, the convolutional neural network accurately detects intermediate phase volume fractions even trained with only pure-phase patterns, achieving a mean square error accuracy of $$9.4 \times 10^{-4}$$ 9.4 × 10 - 4 . Graphical abstract

Yue, Weiqi↗

ARC physics basis–magnetohydrodynamics

ARC is designed to produce 400 ⁢MW of net electricity and prove the commercial feasibility of a fusion power plant. In order to achieve this goal ARC has to operate with optimal core performance in a stationary scenario that minimises wear on the first wall and divertor. This requires avoiding or mitigating magnetohydrodynamic (MHD) instabilities which have the potential to not only degrade the plasma core but also lead to deleterious transient heat loads on plasma facing components. Therefore, this work aims at characterising the MHD stability of the high performance ARC scenario and inform the design of error field correction coils. Firstly, simulations of vertical displacement events show that an in-vessel coil is not needed and instead the poloidal shaping coils can be used to control vertical stability. These simulations also inform the demands on the corresponding coil power supplies. Stability analysis of the ideal kink mode with or without a conducting wall and kinetic effects suggests that the ARC baseline scenario operates deeply in the stable region. Using RDCON, tearing modes at the 𝑚/𝑛 =2/1 and 3/2 surfaces (with poloidal mode number 𝑚, and toroidal mode number 𝑛) are shown to be linearly stable, and including thermal transport effects in the rational surfaces lead to further stabilisation. However, other transient plasma instabilities can seed neoclassical tearing modes (NTMs). The marginally stable width of NTMs in ARC strongly depends on the internal inductance and can fall below 0.1% of the normalised poloidal flux. Furthermore, an empirical cross-machine model of the 𝑛 =1 error field leading to a disruption predicts a critical error field larger than SPARC but smaller than ITER. Three-dimensional coils can be designed with the Generalised Purturbed Equilbium Code based on a simple model that calculates the maximum correctable error field that is limited by the neoclassical toroidal viscosity torque. Broad scans of different coil geometries identify a set of 2 rows of off-midplane coils to be a suitable solution. It is also determined that such a set of three-dimensional coils is capable of correcting 𝑛 =2 error fields to some degree and creating strong enough 𝑛 =2 or 𝑛 =3 edge resonant perturbation fields for the suppression of edge-localised modes at reasonable coil currents. The final design of the first ARC will be further informed by results from SPARC.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Improving snow albedo modeling in the E3SM land model (version 2.0) and assessing its impacts on snow and surface fluxes over the Tibetan Plateau

With the highest albedo of the land surface, snow plays a vital role in Earth's surface energy budget and water cycle. Snow albedo is primarily controlled by snow grain properties (e.g., size and shape) and light-absorbing particles (LAPs) such as black carbon (BC) and dust. The mixing state of LAPs in snow also has impacts on LAP-induced snow albedo reduction and surface radiative forcing (RF). However, most land surface models assume that snow grain shape is spherical and LAPs are externally mixed with the snow grains. This study improves the snow radiative transfer model in the Energy Exascale Earth System Model version 2.0 (E3SM v2.0) Land Model (ELM v2.0) by considering non-spherical snow grain shapes (i.e., spheroid, hexagonal plate, and Koch snowflake) and internal mixing of dust–snow, and it systematically evaluates the impacts on the surface energy budget and water cycle over the Tibetan Plateau (TP). A series of ELM simulations with different treatments of snow grain shape, mixing state of BC–snow and dust–snow, and sub-grid topographic effects (TOP) on solar radiation are performed. Compared with two remote sensing snow products derived from the Moderate Resolution Imaging Spectroradiometer, the control ELM simulation (ELM_Control) with the default configurations of spherical snow grain shape, internal mixing of BC–snow, external mixing of dust–snow, and without TOP as well as the ELM simulation with new model features (ELM_New) can both capture the overall snow distribution reasonably. Additionally, ELM_New overall shows smaller biases in snow cover fraction than ELM_Control in spring when snowmelt is important for water management. The estimated LAP-induced RF in ELM_New ranges from 0 to 19.3 W m -2 with the area-weighted average value of 1.5 W m -2 that is comparable to the reported values in existing studies. The Koch snowflake shape, among other non-spherical shapes, shows the largest difference from the spherical shape in spring when snow processes related to the surface energy budget and water cycle have high importance. The impacts of the mixing state of LAP in snow are smaller than the shape effects and depend on snow grain shape. Compared to external mixing, internal mixing of LAP–snow can lead to larger snow albedo reduction and snowmelt, which further affect the surface energy budget and water cycle. The individual contributions of non-spherical snow shape, mixing state of LAP–snow, and local topography impacts on the snow and surface fluxes have different signs and magnitudes, and their combined effects may be negative or positive due to complex and nonlinear interactions among the factors. Overall, the changes in net solar radiation in spring due to individual and combined effects range from -28.6 to 16.9 W m -2 and -29.7 to 12.2 W m -2 , respectively. This study advances understanding of the role of snow grain shape and mixing state of LAP–snow in land surface processes and offers guidance for improving snow simulations and RF estimates in Earth system models under climate change.

58 GEOSCIENCES↗

NPP Simulators for Coupled Thermal and Electric Power Dispatch

The Light Water Reactor Sustainability (LWRS) program within the United States Department of Energy supports extending the operation of the U.S. commercial nuclear power plant (NPP) fleet. Within the LWRS program, the Flexible Plant Operation and Generation (FPOG) Pathway works to diversify the revenue streams of light water reactors (LWRs) by opening opportunities for the co-generation of non-electric products in addition to supplying electrical power to the grid. Recent events have added greater motivation to these efforts. For example, the recent Inflation Reduction Act (IRA) passed by the U.S. federal government offers substantial tax incentives for producing clean hydrogen, the technology readiness level of dispatchable and high-efficiency hydrogen production has dramatically increased in a short time, and societal response to world climate change is driving a transition away from fossil fuels. Producing hydrogen with maximum efficiency using nuclear power requires dispatching both electrical and thermal power from the nuclear plant to the hydrogen plant, so testing concepts of operations for combined electrical and thermal power dispatch (TPD) from an NNP to a hydrogen plant is of interest. This report documents achievement of the Light Water Reactor Sustainability (LWRS) program milestone “Install and demonstrate a vendor-developed simulator on the Human Systems Simulation Laboratory (HSS) for dispatch of LWR electrical power to a close-coupled electrolysis plant” with a due date of Dec. 22, 2022. Several factors provide motivation for this effort. Coupling the power generation deck of a nuclear power plant to a hydrogen production facility introduces new possibilities for operational transients that must be addressed. In particular, the performance of the integrated system during startup and shutdown of the hydrogen production facility, as well as offnormal conditions, need to be evaluated to ensure there are no adverse effects on the operation of the existing NPP. The concept of operations involving the NPP, the hydrogen plant, and the electric power grid must be tested using NPP simulators and operating procedures that have been modified for TPD operations. These tests must also include dynamic simulations of the coupled tertiary thermal and electric loads as well as coordinated activities with NPP operators, tertiary load operators and grid power coordinators. The report summarizes progress in developing and testing full-scope NPP simulators at the HSSL, including a generic BWR simulator from GSE Systems, Inc. and generic PWR simulator from Westinghouse. In the case of the TPD-GBWR Simulator from GSE Systems, Inc., a BWR is thermally coupled to a high temperature electrolysis (HTE) plant that produces hydrogen and oxygen from de-ionized water. The hydrogen plant is not explicitly simulated but only included as a transient heat sink. A thermal power dispatch (TPD) system transfers heat between the steam systems at the BWR and the hydrogen plant. Operational results from two versions of the modified simulator are presented. The first version uses synthetic oil as a heat transfer fluid in a closed delivery heat loop (DHL) that generates steam at the hydrogen plant. The second version uses steam as the heat transfer fluid in a delivery steam line (DSL) to provide steam to the hydrogen plant. For both versions, the estimated thermal power delivery distance is approximately one kilometer. The amount of thermal power dispatched in the simulators is 15% of the total reactor thermal power such that the simulators provide a tool to study the feasibility of coupling a BWR to industrial processes that benefit from a combination electrical and thermal power dispatch. Ongoing work within a CRADA is also developing a full-scope PWR simulator provided by Westinghouse for both thermal and electric power coupling. This simulator is based on a PWR plant with two three-loop Westinghouse reactors. Westinghouse PWRs are sufficiently similar that a simulator of a three-loop reactor is an appropriate representation for two-loop and four-loop PWR reactors. The three-loop simulator will initially be modified for close-coupling to a 100 MW HTE hydrogen production plant that will require approximately 25 MW of thermal power while operating at its maximum rated capacity. The simulator testing will include full coupling to dynamic simulations of a hydrogen production plant and a representative bulk electric grid. The simulator provided by Westinghouse is similar to the GPWR simulator that INL has already obtained from GSE Systems but has a few important added benefits. First, the Westinghouse simulator is based on digital controls and has additional screens that can be called up to show parameter trends to assist operators in decision-making. The Westinghouse simulator also has upgrades to the controls and hardware representations, such as valve actuators, that make it more realistic and flexible in terms of accurately sim

99 GENERAL AND MISCELLANEOUS↗

Impact of Open Communication Networks on Load Frequency Control with Plug-in Electric Vehicles by Cyber-Physical Dynamic Co-Simulation: Preprint

With the increasing electrification of the transportation sector, vehicle to grid (V2G) control technologies are promising to improving system frequency stability. However, these control technologies might require non-traditional communication supports. This paper investigates the impacts of electric vehicles (EVs) V2G on power system frequency regulation considering communication variations through transmission-distribution-communication (TDC) dynamic simulation. The simulation model is built based on our previously developed open-source transmission-and-distribution (T&D) dynamic co-simulation framework. Here, we add the communication variation functions (i.e. delay and packet loss) to complete the TDC simulation framework. In the case studies, practical communication variation scenarios are considered when the system experiencing an N-1 generation trip contingency. The considered scenarios include communication delay and packet loss using both homogeneous and heterogeneous assumptions. The delay and packet loss rate are the same in all communication channels in the homogeneous case but varies in the heterogeneous case. The results show the communication delay has an obvious impact on the frequency recovery compared to the communication packet drop. The impacts of the standard deviations of communication delay time and packet drop rate are not significant. The outcomes of this work can help improve the EV frequency regulation services and provide robust and effect supports to the grid.

ADVANCED PROPULSION SYSTEMS,ENERGY PLANNING, POLIC↗

FATES crown damage simulation outputs 2022

This dataset contains outputs from the Functionally Assembled Terrestrial Ecosystem Simulator (FATES) and accompanies the paper "Needham, J.F., Arellano, A., Davies, S.J., Fisher, R.A., Hammer, V., Knox, R., Mitre, D., Muller-Landau, H.C., Zuleta, D., Koven, C.D. Tree crown damage and its effects on forest carbon cycling in a tropical forest, 2022, Global Change Biology". Data are unprocessed netcdf file outputs from simulations that were run to test the effect of a new crown damage module in FATES. Specifically, this data package contains a sensitivity analysis to the carbon cushion parameter damage_Ccushion_ensemble_e1b5bd9_bf013ef_2021-09-02.h0.ensemble.sofar.nc, a sensitivity analysis to the root nitrogen stoichiometry parameter damage_Nstoich_ensemble_e1b5bd9_bf013ef_2021-09-02.h0.ensemble.sofar.nc, a sensitivity analysis to parameters controlling crown damage and recovery damage_recovery_ensemble_e1b5bd9_354f0b0_2021-09-02.h0.ensemble.sofar.nc, and a sensitivity analysis to the number of crown damage bins elm_fates_bci_*_damagebins.Eac53ccb80b-F8f994c29.2022-04-19.elm.h0.fullrun.nc. This data package also contains a high root nitrogen configuration of FATES, including both a control, and a crown damage simulation high_root_N_control_e1b5bd9_354f0b0_2021-09-02.clm2.h0.fullrun.nc and high_root_N_damage_e1b5bd9_354f0b0_2021-09-02.clm2.h0.fullrun.nc. There is an analogous low root nitrogen configuration of FATES, including a control, low_root_N_control_e1b5bd9_bf013ef_2021-09-02.clm2.h0.fullrun.nc a damage only simulation low_root_N_damageonly_e1b5bd9_bf013ef_2021-09-02.clm2.h0.fullrun.nc, a damage plus mortality simulation low_root_N_damage_mort_e1b5bd9_bf013ef_2021-09-02.clm2.h0.fullrun.nc, and a mortality only simulation low_root_N_mort_only_e1b5bd9_ef845c8_2021-09-02.clm2.h0.fullrun.nc. Finally, there is a two PFT simulation in which we test the effect of recovery on competitive dynamics, low_root_N_damage_two_pfts_stoichastic_e1b5bd9_bf013ef_2021-09-10.clm2.h0.fullrun.nc. These simulations test the effect of representing crown damage in FATES, compared with simulations that have an equivalent increase in mortality. Jupyter notebooks to analyse these files can be found at https://github.com/JessicaNeedham/Needham_etal_GCB_2022_FATES_crown_damage.

54 ENVIRONMENTAL SCIENCES↗

Design of a Combined Proportional Integral Derivative Controller to Regulate the Temperature Inside a High-Temperature Tubular Solar Reactor

Solar fuels are proven to be promising candidates for thermochemical energy storage. However, the transient nature of solar radiation is an obstacle to maintaining a stable operational temperature inside a solar reactor. To overcome this challenge, the temperature of a solar reactor can be regulated by controlling the incoming solar radiation or the feedstock flowrate inside the reactor. In this work, a combined proportional integral derivative (PID) controller is implemented to regulate the temperature inside a high-temperature tubular solar reactor with counter-current flowing gas/particles. The control model incorporates two control systems to regulate incoming solar radiation and gas flow simultaneously. The design of the controller is based on a reduced-order numerical model of a high-temperature tubular solar reactor that is vertically oriented with an upward gas flow and downward particle flow. The reactor receives heat circumferentially through its wall over a finite segment of its length. Formulation of the heat transfer model is presented by applying the energy balance for the reactor tube and considering heat and mass transfer inside. A set of governing differential equations are solved numerically by using the finite volume method to obtain reactor wall, particles, and gas temperatures along the reactor length with various boundary conditions. Simulation results are used to tune the PID controller parameters by utilizing the Ziegler–Nichols tuning method. Both the simulation results and the controller performance are visualized on the LABVIEW platform. The controller is challenged to track different temperature setpoints with different scenarios of transient solar radiation. Here, the performance of the PID controller was compared to experimental results obtained from an industrial PID controller embedded in a 7 kW electric furnace. Results show that the combined PID controller is successful in maintaining a stable temperature inside the reactor by regulating the incoming solar radiation and the flowrate via small steady-state error and reasonable settling time and overshoot.

14 SOLAR ENERGY↗

Nonlinear Multiobjective MPC-Based Optimal Operation of a High Consistency Refining System in Papermaking

As one of the most important unit in the papermaking industry, the high consistency (HC) refining system is confronted with challenges such as improving pulp quality, energy saving, and emissions reduction in its operation processes. Here in this correspondence, an optimal operation of HC refining system is presented using nonlinear multiobjective model predictive control strategies that aim at set-point tracking objective of pulp quality, economic objective, and specific energy (SE) consumption objective, respectively. First, a set of input and output data at different times are employed to construct the subprocess model of the state process model for the HC refining system, and then the Wiener-type model can be obtained through combining the mechanism model of Canadian Standard Freeness and the state process model that determines their structures based on Akaike information criterion. Second, the multiobjective optimization strategy that optimizes both the set-point tracking objective of pulp quality and SE consumption is proposed simultaneously, which uses NSGA-II approach to obtain the Pareto optimal set. Furthermore, targeting at the set-point tracking objective of pulp quality, economic objective, and SE consumption objective, the sequential quadratic programming method is utilized to produce the optimal predictive controllers. In conclusion, the simulation results demonstrate that the proposed methods can make the HC refining system provide a better performance of set-point tracking of pulp quality when these predictive controllers are employed. In addition, while the optimal predictive controllers orienting with comprehensive economic objective and SE consumption objective, it has been shown that they have significantly reduced the energy consumption.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

DISTRI: Distributed Multi-Facility HPC Simulator (DISTRI) v2.1

DISTRI is an advanced network simulator designed for multi-facility computational infrastructures with agentic behavior. It simulates HPC facilities where computational resources act as autonomous agents, making intelligent decisions about job scheduling, load balancing, and resource allocation. The simulator focuses on developing and testing decentralized algorithms that promote resilience and efficiency in multi-facility environments. Key Features: - Agentic Resource Behavior: Processors and DTNs act as autonomous agents with decision-making capabilities - Pheromone-Based Load Balancing: Decentralized load balancing inspired by ant colony optimization - Dual Topology Support: Mesh (normal operations) and Dumbell (network testing) topologies - Comprehensive TCP Simulation: Realistic TCP implementations with multiple congestion control algorithms - Failure Resilience Testing: Processor failure simulation with automatic job reassignment - Extensive Visualization: Detailed performance analysis and metrics collection - Research-Ready: Designed for algorithm development and benchmarking

Bez, Jean Luca [Lawrence Berkeley National Laborat↗

Stabilizing the Grid and Reducing Utility Bills Through Price-Responsive Controls for Heat Pump Water Heaters

The electricity grid is facing increasing challenges in cost-effectively balancing supply and demand. These challenges are exacerbated by increased penetration of photovoltaics, which causes mid-day overproduction, and electrification of gas appliances, which increases peak-period electricity demand. Decarbonization requires shifting building loads from fossil-intensive high-cost times to renewable-intensive low-cost times while maintaining quality of service to occupants. Utilities and ISO’s are investigating new ways of incentivizing this load shifting. One promising method is the use of Highly Dynamic Prices (HDPs). HDPs feature continuously changing prices that reflect real-time grid generation and distribution costs and capacity constraints, and thus incentivize consumers to shift their loads. California’s CPUC CalFUSE proposal and Hawaii’s recent changes demonstrate that electricity tariffs are moving towards this model. For this to work however, loads must have the capability to respond to these prices. Heat pump water heaters (HPWHs) are an ideal device for this purpose because their storage tanks decouple delivery of domestic hot water from electricity consumption. The storage enables control strategies that consume midday solar power to increase the energy stored in the tank, then provide evening peak domestic hot water services using the stored energy. Berkeley Lab's CalFlexHub project is pioneering price-driven load flexibility by developing and deploying cost-minimizing controls for many flexible loads - including HPWHs - in response to HDP. Control development is based on simulations using the Flexible Heat Pump Water Heater Performance Predictor which captures the control decisions of the on-board controller in a residential, integrated HPWH . The price-responsive controls a) shift load in ways that consume additional midday solar power to help stabilize the grid and reduce overall emissions, b) ensure that occupants receive equal or better hot water delivery service, and c) minimize the operating cost for each home in the fleet. On the grid level, the resulting shift will reduce utility operating costs and emissions, and can avoid expensive system capacity expansions. The control approach is customized to each home based on typical hot water consumption patterns. HPWH controllers, whether on the device or remotely, will receive a schedule of CTA-2045-B signals or set temperature adjustments customized to the current HDP price schedule and home. Simulation results for a fleet of 148 HPWHs on a summer day in Berkeley, California show cost savings of 29% and high price electricity consumption reductions of 80%, while maintaining full quality of service.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Co-Simulation Model for Optimal Wind-Hydro Coordination Using Wind Farm Control Dynamics

The growing share of Variable Renewable Energy sources (VRES) in power systems presents challenges for regula- tors, grid operators and energy producers. The VRES’ operation has limited flexibility in their operations, as they are highly dependent on ambient environments. To address these challenges, decision-makers must consider multiple objectives, among these are revenue, power system services and mechanical load on wind turbines. Coordinated operation of power plants and different wind farm control strategies are examples of measures that can benefit these objectives. This study proposes a Multi-Objective Linear Programming (MOLP) model to simulate the optimum operation of wind and hydropower plants that share limited transmission capacity. Further, wind farm control dynamics are included to obtain realistic output power and accumulated damage. From this, a case study based on a relevant location in Norway is presented to analyze the improved effect of wind- hydro coordination and wind farm control in achieving the objectives of accumulated wind turbine damage and total revenue of the hybrid power system. In addition, the study considers the potential advantages of adding a variable-speed pump to the hydropower plant. The results demonstrate that by considering multiple objectives in the optimization, one may achieve better overall performance of the objectives. By utilizing the flexibility of hydro storage, the decision maker may adjust to obtain the most desired outcome. Moreover, the added flexibility of utilizing a pump for hydro storage shows great improvements for the combined revenue of the power plants and reduced curtailment of the wind farm. However, less impact is observed from using a variable speed pump compared to a fixed speed pump.

13 HYDRO ENERGY↗

Modeling Framework for Data Center

This chapter highlights the critical need for advanced modeling of data centers due to their rapidly increasing energy consumption and impact on grid reliability. Driven by the demand for AI applications, data centers are projected to consume a significant portion of US energy by 2028, putting stress on an already challenged power grid. The chapter emphasizes the importance of "fast" time-scale models to understand the dynamic interactions between data centers and the grid, especially given the rapid power fluctuations of AI workloads. It outlines a modeling framework that includes both offline and real-time EMT domain simulations, detailing the necessary representations for various components like utility interfaces, transformers, IT loads, UPS, cooling loads, Battery Energy Storage Systems (BESS), generators, protection systems, and higher-level control systems. While standard simulation tools like PSCAD offer basic models, custom development is often required to accurately capture the unique and fast-changing behaviors of modern data centers. The chapter also discusses key metrics and test cases for validating these models, focusing on transient load responses, protection relay coordination, and demand flexibility. Finally, it addresses the challenges of modeling large-scale data centers, such as computational complexity and the trade-off between model fidelity and practicality, suggesting hybrid modeling approaches as a solution. The overarching goal is to create a robust framework that helps assess data center impacts on grid stability, identify vulnerabilities, and inform the development of standards for reliable integration of these large loads into the bulk power system.

25 ENERGY STORAGE↗

Co-simulation Framework for Community-scale Building-grid Integration [SWR-21-75]

Distributed energy resources (DERs), including rooftop solar, energy storage, and flexible loads, are gaining popularity as costs decline and as building owners and utilities realize their benefits. DERs can improve distribution system efficiency, help prevent the need for expensive grid upgrades, and increase the resilience of local communities. However, they can also cause difficulties in grid operations and can require controls to achieve their benefits. To address this challenge, NREL researchers have developed a community-scale solution that assesses the impacts of DERs and their control strategies on a distribution system. The framework has been shown to reduce solar photovoltaic (PV) curtailment to 0%, mitigate the adverse impact of solar variability on the distribution voltage, and provide up to 5-day critical load support during emergency events. Utilizing 5 different modules representing the feeder, buildings, home energy management systems, an aggregator, and a utility controller, NREL expects this simulation technology to play a critical role in the continued integration of DERs. According to the Energy Information Administration (EIA), solar curtailments accounted for 94% of the total energy curtailed in the California Independent System Operator (CAISO) in 2020. By enabling Independent System Operators (ISOs) and utility operators to bring solar curtailments to 0%, the electrical grid can become less dependent on fossil-fueled power generation sources. NREL's co-simulation framework contains five major components: Distribution Feeder Model: describes the distribution feeder topology using OpenDSS, including the locations of all DERs. Residential Building Model: simulates a large number of buildings at a high resolution using OCHRETM. The model is equipped to control equipment based on signals from an external module. The model includes major household appliances such as HVAC and a water heater, non-dispatchable load models, a distributed PV system, and a home battery system. Home Energy Management System: optimizes the controls for the devices in a home using foreseeTM. The control can adjust based on the user preferences including cost, comfort, and convenience. In hierarchical control scenarios, where the houses follow signals from an aggregator, the home energy management system provides a flexibility band with a range of power and follows the dispatch signals received from aggregator. Community-Level Aggregator: solves for optimal energy dispatch based on the flexibility bands received from each home and the grid service signal received from the utility controller. Utility-Level Controller: provides grid signals for voltage control using Distributed Energy Resources (DERs), such as solar systems, in the community.

Balamurugan, Sivasathya Pradha↗

Dynamics and Control of Microgrids as a Resiliency Source

Microgrids can be operated in a utility-connected mode with the neighboring distribution system or in an islanded mode in separation with the distribution system. As the major disasters occur more and more often, islanded microgrid is proposed as a possible solution to serve essential loads until the utility service is restored. This paper evaluates the feasibility of using microgrids as a resiliency resource by a field test. A control scheme, integrating droop control and feedback control, is applied on a modified IEEE 13-node test feeders. The simulation results validate the proposed control scheme and the transient stability

Lee, Lung-An↗

Learning Local Volt/VAR Controllers Toward Efficient Network Operation with Stability Guarantees: Preprint

This paper considers the problem of voltage regulation in distribution network. The primary motivation is to keep voltages within pre-assigned operating limits by commanding the reactive power output of distributed energy resources (DERs) deployed in the grid. We develop a framework for developing local Volt/Var control that comprises of two main steps. In the first, exploiting historical data and for each DER, we learn a function representing desirable equilibrium points for the power network. These points approximate solutions of an Optimal Power Flow problem. In the second, we propose a control scheme for steering the network towards these favorable configurations. Theoretical conditions are derived to formally guarantee the stability of the developed control scheme and numerical simulations illustrate the effectiveness of the proposed approach.

data-driven control↗

Floating Wind Turbine Control Optimization

We present a framework for optimizing the control parameters of floating offshore wind turbines (FOWTs). The framework combines aeroelastic simulations with a systems engineering model and control software. In an example of the optimization framework, we minimize tower damage equivalent loading with generator speed constraints. We also study the effect of thrust-limiting control and quantify the trade off between fatigue loading and energy capture using a set of optimal controller designs. Finally, we optimize the controller of four different FOWT models and compare their dynamic responses. Additional details and other use cases for the framework are presented, which can optimize different control problems and evaluate FOWT designs.

controls↗