Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “computerized procedures”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

Portal Vein Embolization with Contralateral Application of Stem Cells Facilitates Increase of Future Liver Remnant Volume in Patients with Liver Metastases

ObjectivesThis study aimed to evaluate the progress of future liver remnant volume (FLRV) in patients with liver metastases after portal vein embolization (PVE) with the application of hematopoietic stem cells (HSCs) and compare it with a patients control group after PVE only.MethodsTwenty patients (group 1) underwent PVE with contralateral HSC application. Subsequently, CT volumetry with the determination of FLRV was performed at weekly intervals, in total three weeks. A sample of twenty patients (group 2) who underwent PVE without HSC application was used as a control group.ResultsThe mean of FLRV increased by 173.2 mL during three weeks after the PVE/HSC procedure, whereas by 98.9 mL after PVE only (p = 0.015). Furthermore, the mean daily growth of FLRV by 7.6 mL in group 1 was significantly higher in comparison with 4.1 mL in group 2 (p = 0.007).ConclusionsPVE with the application of HSC significantly facilitates growth of FLRV in comparison with PVE only. This method could be one of the new suitable approaches to increase the resectability of liver tumours.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Current induced magnetization switching in Co/Cu/Ni-Fe nanopillar with orange peel coupling

The impact of orange peel coupling on spin current induced magnetization switching in a Co/Cu/Ni-Fe nanopillar device is investigated by solving the switching dynamics of magnetization of the free layer governed by the Landau-Lifshitz-Gilbert-Slonczewski (LLGS) equation. The value of the critical current required to initiate the magnetization switching is calculated analytically by solving the LLGS equation and verified the same through numerical analysis. Results of numerical simulation of the LLGS equation using Runge-Kutta fourth order procedure shows that the presence of orange peel coupling between the spacer and the ferromagnetic layers reduces the switching time of the nanopillar device from 67 ps to 48 ps for an applied current density of 4 × 10{sup 12}Am{sup −2}. Also, the presence of orange peel coupling reduces the critical current required to initiate switching, and in this case, from 1.65 × 10{sup 12}Am{sup −2} to 1.39 × 10{sup 12}Am{sup −2}.

36 MATERIALS SCIENCE↗

SU-F-E-01: Pitfalls: Reliability and Performance of Diagnostic X-Sources

Purpose: Performance and reliability of medical X-ray tubes for imaging are crucial from an ethical, clinical and economic perspective. This lecture will deliver insight into the aspects to consider during the decision making process to invest in X-ray imaging equipment. Outdated metric still hampers realistic product comparison. It is time to change this and to comply with latest standards, which consider current technology. Failure modes and ways to avoid down-time of the equipment shall be discussed. In view of the increasing number of interventional procedures and the hazards associated with ionizing radiation, toxic contrast agents, and the combination thereof, the aspect of system reliability is of paramount importance. Methods: A comprehensive picture of trends for different modalities (CT, angiography, general radiology) has been drawn and led to the development of novel X-ray tube technology. Results: Recent X-ray tubes feature enhanced reliability and unprecedented performance. Relevant metrics for product comparison still have to be implemented in practice. Conclusion: The speed of scientific and industrial development of new diagnostic and therapeutic X-ray sources remains tremendous. Still, users suffer from gaps between desire and reality in day-to-day diagnostic routine. X-ray sources are still limiting cutting-edge medical procedures. Side-effects of wear and tear, limitations of the clinical work flow, costs, the characteristics of the X-ray spectrum and others topics need to be further addressed. New applications and modalities, like detection-based color-resolved X-ray and phase-contrast / dark-field imaging will impact the course of new developments of X-ray sources. The author is employee of Royal Philips.

60 APPLIED LIFE SCIENCES↗

Automation of vibroacoustic data bank for random vibration criteria development

A computerized data bank system was developed for utilization of large amounts of vibration and acoustic data to formulate component random vibration design and test criteria. This system consists of a computer, graphics tablet, and a dry-silver hard copier which are all desk-top type hardware and occupy minimal space. The data bank contains data from the Saturn V and Titan III flight and static test programs. The vibration and acoustic data are stored in the form of power spectral density and one-third octave band plots over the frequency range from 20 to 2000 Hz. The data was stored by digitizing each spectral plot by tracing with the graphics tablet. The digitized data was statistically analyzed and the resulting 97.5% probability levels were stored on tape along with the appropriate structural parameters. Standard extrapolation procedures were programmed for prediction of component random vibration test criteria for new launch vehicle and payload configurations. This automated vibroacoustic data bank system greatly enhances the speed and accuracy of formulating vibration test criteria. In the future, the data bank will be expanded to include all data acquired from the space shuttle flight test program.

Ferebee, R. C.↗

Fluid dynamic modeling of nano-thermite reactions

This paper presents a direct numerical method based on gas dynamic equations to predict pressure evolution during the discharge of nanoenergetic materials. The direct numerical method provides for modeling reflections of the shock waves from the reactor walls that generates pressure-time fluctuations. The results of gas pressure prediction are consistent with the experimental evidence and estimates based on the self-similar solution. Artificial viscosity provides sufficient smoothing of shock wave discontinuity for the numerical procedure. The direct numerical method is more computationally demanding and flexible than self-similar solution, in particular it allows study of a shock wave in its early stage of reaction and allows the investigation of “slower” reactions, which may produce weaker shock waves. Moreover, numerical results indicate that peak pressure is not very sensitive to initial density and reaction time, providing that all the material reacts well before the shock wave arrives at the end of the reactor.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

The effect of head size/shape, miscentering, and bowtie filter on peak patient tissue doses from modern brain perfusion 256-slice CT: How can we minimize the risk for deterministic effects?

Purpose: To determine patient-specific absorbed peak doses to skin, eye lens, brain parenchyma, and cranial red bone marrow (RBM) of adult individuals subjected to low-dose brain perfusion CT studies on a 256-slice CT scanner, and investigate the effect of patient head size/shape, head position during the examination and bowtie filter used on peak tissue doses. Methods: The peak doses to eye lens, skin, brain, and RBM were measured in 106 individual-specific adult head phantoms subjected to the standard low-dose brain perfusion CT on a 256-slice CT scanner using a novel Monte Carlo simulation software dedicated for patient CT dosimetry. Peak tissue doses were compared to corresponding thresholds for induction of cataract, erythema, cerebrovascular disease, and depression of hematopoiesis, respectively. The effects of patient head size/shape, head position during acquisition and bowtie filter used on resulting peak patient tissue doses were investigated. The effect of eye-lens position in the scanned head region was also investigated. The effect of miscentering and use of narrow bowtie filter on image quality was assessed. Results: The mean peak doses to eye lens, skin, brain, and RBM were found to be 124, 120, 95, and 163 mGy, respectively. The effect of patient head size and shape on peak tissue doses was found to be minimal since maximum differences were less than 7%. Patient head miscentering and bowtie filter selection were found to have a considerable effect on peak tissue doses. The peak eye-lens dose saving achieved by elevating head by 4 cm with respect to isocenter and using a narrow wedge filter was found to approach 50%. When the eye lies outside of the primarily irradiated head region, the dose to eye lens was found to drop to less than 20% of the corresponding dose measured when the eye lens was located in the middle of the x-ray beam. Positioning head phantom off-isocenter by 4 cm and employing a narrow wedge filter results in a moderate reduction of signal-to-noise ratio mainly to the peripheral region of the phantom. Conclusions: Despite typical peak doses to skin, eye lens, brain, and RBM from the standard low-dose brain perfusion 256-slice CT protocol are well below the corresponding thresholds for the induction of erythema, cataract, cerebrovascular disease, and depression of hematopoiesis, respectively, every effort should be made toward optimization of the procedure and minimization of dose received by these tissues. The current study provides evidence that the use of the narrower bowtie filter available may considerably reduce peak absorbed dose to all above radiosensitive tissues with minimal deterioration in image quality. Considerable reduction in peak eye-lens dose may also be achieved by positioning patient head center a few centimeters above isocenter during the exposure.

60 APPLIED LIFE SCIENCES↗

Superficial dosimetry imaging based on Čerenkov emission for external beam radiotherapy with megavoltage x-ray beam

Purpose: Čerenkov radiation emission occurs in all tissue, when charged particles (either primary or secondary) travel at velocity above the threshold for the Čerenkov effect (about 220 KeV in tissue for electrons). This study presents the first examination of optical Čerenkov emission as a surrogate for the absorbed superficial dose for MV x-ray beams.Methods: In this study, Monte Carlo simulations of flat and curved surfaces were studied to analyze the energy spectra of charged particles produced in different regions near the surfaces when irradiated by MV x-ray beams. Čerenkov emission intensity and radiation dose were directly simulated in voxelized flat and cylindrical phantoms. The sampling region of superficial dosimetry based on Čerenkov radiation was simulated in layered skin models. Angular distributions of optical emission from the surfaces were investigated. Tissue mimicking phantoms with flat and curved surfaces were imaged with a time domain gating system. The beam field sizes (50 × 50–200 × 200 mm{sup 2}), incident angles (0°–70°) and imaging regions were all varied.Results: The entrance or exit region of the tissue has nearly homogeneous energy spectra across the beam, such that their Čerenkov emission is proportional to dose. Directly simulated local intensity of Čerenkov and radiation dose in voxelized flat and cylindrical phantoms further validate that this signal is proportional to radiation dose with absolute average discrepancy within 2%, and the largest within 5% typically at the beam edges. The effective sampling depth could be tuned from near 0 up to 6 mm by spectral filtering. The angular profiles near the theoretical Lambertian emission distribution for a perfect diffusive medium, suggesting that angular correction of Čerenkov images may not be required even for curved surface. The acquisition speed and signal to noise ratio of the time domain gating system were investigated for different acquisition procedures, and the results show there is good potential for real-time superficial dose monitoring. Dose imaging under normal ambient room lighting was validated, using gated detection and a breast phantom.Conclusions: This study indicates that Čerenkov emission imaging might provide a valuable way to superficial dosimetry imaging in real time for external beam radiotherapy with megavoltage x-ray beams.

61 RADIATION PROTECTION AND DOSIMETRY↗

MO-G-18A-01: Radiation Dose Reducing Strategies in CT, Fluoroscopy and Radiography

Advances in medical x-ray imaging have provided significant benefits to patient care. According to NCRP 160, there are more than 400 million x-ray procedures performed annually in the United States alone that contributes to nearly half of all the radiation exposure to the US population. Similar growth trends in medical x-ray imaging are observed worldwide. Apparent increase in number of medical x-ray imaging procedures, new protocols and the associated radiation dose and risk has drawn considerable attention. This has led to a number of technological innovations such as tube current modulation, iterative reconstruction algorithms, dose alerts, dose displays, flat panel digital detectors, high efficient digital detectors, storage phosphor radiography, variable filters, etc. that are enabling users to acquire medical x-ray images at a much lower radiation dose. Along with these, there are number of radiation dose optimization strategies that users can adapt to effectively lower radiation dose in medical x-ray procedures. The main objectives of this SAM course are to provide information and how to implement the various radiation dose optimization strategies in CT, Fluoroscopy and Radiography. Learning Objectives: To update impact of technological advances on dose optimization in medical imaging. To identify radiation optimization strategies in computed tomography. To describe strategies for configuring fluoroscopic equipment that yields optimal images at reasonable radiation dose. To assess ways to configure digital radiography systems and recommend ways to improve image quality at optimal dose.

60 APPLIED LIFE SCIENCES↗

Multigroup cross section generation capability in GRIFFIN

GRIFFIN is an advanced reactor multiphysics application built on the object-oriented simulation environment (MOOSE) and is jointly developed by Idaho National Laboratory and Argonne National Laboratory. The cross section application programming interface, originally developed for the PROTEUS code, has been integrated into GRIFFIN to prepare cross sections for thermal reactor applications with heterogeneous geometries. Additional improvements have been made by implementing an on-the-fly slowing down method, a double heterogeneity treatment capability, and updating the procedure to generate the fine multigroup library. The cross section preparation capability in GRIFFIN was verified for graphite-moderated TRISO fuel-based reactor benchmark problems: unit-cell problems of VHTR and EMPIRE micro reactor and HTTR assembly problems. Eigenvalues and multigroup cross sections of GRIFFIN agreed very well with those of the continuous-energy Monte Carlo code Serpent2 within 200 pcm in eigenvalue and 2% in cross sections. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Percutaneous Cryotherapy for Treatment of Chondroblastoma: Early Experience

Surgical curettage is currently the standard of care for the chondroblastoma, but in peri-articular tumors it is limited by its morbidity. In this preliminary report, we evaluate the feasibility of percutaneous cryotherapy as an alternative ablative treatment for chondroblastoma. Three patients with a chondroblastoma treated by CT scan-guided cryotherapy are presented in this article. Pain permanently disappeared 2 days after the procedure. No local tumor recurrence or cartilage damage was observed by MRI performed 1 year after the intervention. This preliminary case report suggests that percutaneous cryotherapy may be a possible alternative to the current standard of care in chondroblastoma. Further studies are needed to evaluate if this technique offers similar anti-tumoral efficacy while providing better pain relief and less morbidity than curettage.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Neutronics Modeling of the pulsed plasma rocket reactor using rattlesnake

In the pulsed plasma rocket (PPR) reactor, neutron induced fission processes are utilized to implement a series of pulsed micro-explosions of very high power and eject plasma as a propellant. More specifically, projectiles (bullets) composed of moderated uranium are sent through the chamber of an unmoderated uranium barrel. By inducing rapid fission within the bullets, a plasma can be generated with appropriate delivery of neutrons. This study aims to assess the neutronics performance of the PPR reactor during normal operations using the MOOSE-based Rattlesnake code through the evaluation of the impact of the movement of the fuel bullet and the rotation of control drums on the criticality of the system. The Monte Carlo (MC) code Serpent 2 was employed to generate material-based cross sections for use in Rattlesnake and the reference neutronics solution. Cubit was used to generate the mesh for the Rattlesnake model. Parametric studies were conducted to evaluate the best approaches for cross section and mesh generation to ensure accurate results from Rattlesnake. As part of the verification process, the eigenvalue results of the system at various fuel bullet positions were obtained using Rattlesnake and compared with the reference solutions. The acceptable differences show that the Rattlesnake model with appropriate cross section and mesh generation procedure is a sufficiently accurate approximation of the continuous energy (CE) MC model for micro-sized reactors like the PPR reactor. Next, the impact of the rotation of the control drums on the system criticality was evaluated using the verified model. It was shown that the high-fidelity simulation using the deterministic code Rattlesnake can produce sufficiently accurate results for the evaluation of the reactor's neutronics performance in different phases of the normal operation with acceptable computational cost.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Initial Comparison of Direct and Legacy Modeling Approaches for Radial Core Expansion Analysis

Radial core expansion in sodium-cooled fast reactors provides an important reactivity feedback effect. As the reactor power increases due to normal start up conditions or accident scenarios, the core and surrounding materials heat up, causing both grid plate expansion and bowing of the assembly ducts. When the core restraint system is designed correctly, the resulting structural deformations introduce negative reactivity which decreases the reactor power. Historically, an indirect procedure has been used to estimate the reactivity feedback due to structural deformation which relies upon perturbation theory and coupling legacy physics codes with limited geometry capabilities. With advancements in modeling and simulation, radial core expansion phenomena can now be modeled directly, providing an assessment of the accuracy of the reactivity feedback coefficients generated by indirect legacy methods. Recently a new capability was added to the PROTEUS-SN unstructured geometry neutron transport solver to analyze deformed meshes quickly and directly. By supplying the deformed mesh in addition to the base configuration input files, PROTEUS-SN automatically processes material adjustments including calculation of region densities to conserve mass, calculation of isotopic densities according to material models (for example, sodium density as a function of temperature), and subsequent re-homogenization of materials. To verify the new capability of directly simulating deformed meshes, PROTEUS-SN was used to compute reactivity feedback for a series of contrived yet representative deformed configurations for the Advanced Burner Test Reactor design. The indirect legacy procedure was also performed to generate reactivity feedback coefficients for the same deformed configurations. Interestingly, the legacy procedure consistently overestimated reactivity feedbacks by 35% compared to direct simulations by PROTEUS-SN. This overestimation indicates that the legacy procedures are in fact not conservative and could be overestimating reactivity feedback effects that are closely tied to reactor safety. We conclude that there is indeed value in performing direct simulation of deformed meshes despite the increased computational expense. PROTEUS-SN is already part of the SHARP multi-physics toolkit where both thermal hydraulics and structural mechanical feedback modeling can be applied but this is the first comparison of direct simulation to legacy techniques for radial core expansion.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Oxygen transport properties estimation by DSMC-CT simulations

Coupling DSMC simulations with classical trajectories calculations is emerging as a powerful tool to improve predictive capabilities of computational rarefied gas dynamics. The considerable increase of computational effort outlined in the early application of the method (Koura,1997) can be compensated by running simulations on massively parallel computers. In particular, GPU acceleration has been found quite effective in reducing computing time (Ferrigni,2012; Norman et al.,2013) of DSMC-CT simulations. The aim of the present work is to study rarefied Oxygen flows by modeling binary collisions through an accurate potential energy surface, obtained by molecular beams scattering (Aquilanti, et al.,1999). The accuracy of the method is assessed by calculating molecular Oxygen shear viscosity and heat conductivity following three different DSMC-CT simulation methods. In the first one, transport properties are obtained from DSMC-CT simulations of spontaneous fluctuation of an equilibrium state (Bruno et al, Phys. Fluids, 23, 093104, 2011). In the second method, the collision trajectory calculation is incorporated in a Monte Carlo integration procedure to evaluate the Taxman’s expressions for the transport properties of polyatomic gases (Taxman,1959). In the third, non-equilibrium zero and one-dimensional rarefied gas dynamic simulations are adopted and the transport properties are computed from the non-equilibrium fluxes of momentum and energy. The three methods provide close values of the transport properties, their estimated statistical error not exceeding 3%. The experimental values are slightly underestimated, the percentage deviation being, again, few percent.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Robust methods for automatic image-to-world registration in cone-beam CT interventional guidance

Purpose: Real-time surgical navigation relies on accurate image-to-world registration to align the coordinate systems of the image and patient. Conventional manual registration can present a workflow bottleneck and is prone to manual error and intraoperator variability. This work reports alternative means of automatic image-to-world registration, each method involving an automatic registration marker (ARM) used in conjunction with C-arm cone-beam CT (CBCT). The first involves a Known-Model registration method in which the ARM is a predefined tool, and the second is a Free-Form method in which the ARM is freely configurable. Methods: Studies were performed using a prototype C-arm for CBCT and a surgical tracking system. A simple ARM was designed with markers comprising a tungsten sphere within infrared reflectors to permit detection of markers in both x-ray projections and by an infrared tracker. The Known-Model method exercised a predefined specification of the ARM in combination with 3D-2D registration to estimate the transformation that yields the optimal match between forward projection of the ARM and the measured projection images. The Free-Form method localizes markers individually in projection data by a robust Hough transform approach extended from previous work, backprojected to 3D image coordinates based on C-arm geometric calibration. Image-domain point sets were transformed to world coordinates by rigid-body point-based registration. The robustness and registration accuracy of each method was tested in comparison to manual registration across a range of body sites (head, thorax, and abdomen) of interest in CBCT-guided surgery, including cases with interventional tools in the radiographic scene. Results: The automatic methods exhibited similar target registration error (TRE) and were comparable or superior to manual registration for placement of the ARM within {approx}200 mm of C-arm isocenter. Marker localization in projection data was robust across all anatomical sites, including challenging scenarios involving the presence of interventional tools. The reprojection error of marker localization was independent of the distance of the ARM from isocenter, and the overall TRE was dominated by the configuration of individual fiducials and distance from the target as predicted by theory. The median TRE increased with greater ARM-to-isocenter distance (e.g., for the Free-Form method, TRE increasing from 0.78 mm to 2.04 mm at distances of {approx}75 mm and 370 mm, respectively). The median TRE within {approx}200 mm distance was consistently lower than that of the manual method (TRE = 0.82 mm). Registration performance was independent of anatomical site (head, thorax, and abdomen). The Free-Form method demonstrated a statistically significant improvement (p= 0.0044) in reproducibility compared to manual registration (0.22 mm versus 0.30 mm, respectively). Conclusions: Automatic image-to-world registration methods demonstrate the potential for improved accuracy, reproducibility, and workflow in CBCT-guided procedures. A Free-Form method was shown to exhibit robustness against anatomical site, with comparable or improved TRE compared to manual registration. It was also comparable or superior in performance to a Known-Model method in which the ARM configuration is specified as a predefined tool, thereby allowing configuration of fiducials on the fly or attachment to the patient.

60 APPLIED LIFE SCIENCES↗

Spontaneous Intramuscular Hematomas of the Abdomen and Pelvis: A New Multilevel Algorithm to Direct Transarterial Embolization and Patient Management

PurposeTo report our experience using a multilevel patient management algorithm to direct transarterial embolization (TAE) in managing spontaneous intramuscular hematoma (SIMH).Materials and MethodsFrom May 2006 to January 2014, twenty-seven patients with SIMH had been referred for TAE to our Radiology department. Clinical status and coagulation characteristics of the patients are analyzed. An algorithm integrating CT findings is suggested to manage SIMH. Patients were classified into three groups: Type I, SIMH with no active bleeding (AB); Type II, SIMH with AB and no muscular fascia rupture (MFR); and Type III, SIMH with MFR and AB. Type II is furthermore subcategorized as IIa, IIb and IIc. Types IIb, IIc and III were considered for TAE. The method of embolization as well as the material been used are described. Continuous variables are presented as mean ± SD. Categorical variables are reported as percentages. Technical success, clinical success, complications and 30-day mortality (d30 M) were analyzed.ResultsTwo patients (7.5%) had Type IIb, four (15%) Type IIc and 21 (77.5%) presented Type III. The detailed CT and CTA findings, embolization procedure and materials used are described. Technical success was 96% with a complication rate of 4%. Clinical success was 88%. The bleeding-related thirty-day mortality was 15% (all with Type III).ConclusionTAE is a safe and efficient technique to control bleeding that should be considered in selected SIMH as soon as possible. The proposed algorithm integrating CT features provides a comprehensive chart to select patients for TAE.Level of Evidence4.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Use of Bone Scan During Initial Prostate Cancer Workup, Downstream Procedures, and Associated Medicare Costs

Purpose: For patients with a high likelihood of having metastatic disease (high-risk prostate cancer), bone scan is the standard, guideline-recommended test to look for bony metastasis. We quantified the use of bone scans and downstream procedures, along with associated costs, in patients with high-risk prostate cancer, and their use in low- and intermediate-risk patients for whom these tests are not recommended. Methods and Materials: Patients in the Surveillance, Epidemiology, and End Results (SEER)-Medicare database diagnosed with prostate cancer from 2004 to 2007 were included. Prostate specific antigen (PSA), Gleason score, and clinical T stage were used to define D'Amico risk categories. We report use of bone scans from the date of diagnosis to the earlier of treatment or 6 months. In patients who underwent bone scans, we report use of bone-specific x-ray, computed tomography (CT), and magnetic resonance imaging (MRI) scans, and bone biopsy within 3 months after bone scan. Costs were estimated using 2012 Medicare reimbursement rates. Results: In all, 31% and 48% of patients with apparent low- and intermediate-risk prostate cancer underwent a bone scan; of these patients, 21% underwent subsequent x-rays, 7% CT, and 3% MRI scans. Bone biopsies were uncommon. Overall, <1% of low- and intermediate-risk patients were found to have metastatic disease. The annual estimated Medicare cost for bone scans and downstream procedures was $11,300,000 for low- and intermediate-risk patients. For patients with apparent high-risk disease, only 62% received a bone scan, of whom 14% were found to have metastasis. Conclusions: There is overuse of bone scans in patients with low- and intermediate-risk prostate cancers, which is unlikely to yield clinically actionable information and results in a potential Medicare waste. However, there is underuse of bone scans in high-risk patients for whom metastasis is likely.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Influence of molecular clustering on the interpretation of diffractograms of hydrocarbon films from tokamak T-10

The influence of molecular clustering on the formerly suggested interpretation of diffraction patterns of hydrocarbon films formed in the vacuum vessel of the tokamak T-10 is analyzed numerically. The simulation of clustering of simple hydrocarbon molecules C(D, H){sub 4}, C{sub 2}(D, H){sub 4}, and C{sub 6}(D, H){sub 6} and molecules composed of curved graphene (fullerenes and toroidal nanotubes) is carried out with the rigid body molecular dynamics method. It is shown that formerly neglected atomic correlations C–C and C–D(H) in the amorphous hydrocarbon component decrease the calculated values of the scattered intensity in the range of scattering vector modulus 5 < q < 20 nm{sup –1} because of homogenization of scatters on the spatial scale of ∼1 nm. The allowance for these correlations does not change the diffraction patterns in the range q > 20 nm{sup –1}. The results suggest the necessity to introduce to the procedure of determining the structural content of the films, similar to those from the tokamak T-10, the clusters formed by the van der Waals adhesion of hydrocarbon molecules to “graphene” nanoparticles. This simplifies the mathematical optimization to the former level of complexity—but for an extended ensemble of objects—and makes it possible to calculate the diffraction patterns of these objects using the distributed computing resources. A modified algorithm of structural content identification on the basis of joint X-ray and neutron diffractometry is suggested.

36 MATERIALS SCIENCE↗

SU-E-T-255: Development of a Michigan Quality Assurance (MQA) Database for Clinical Machine Operations

Purpose: A unified database system was developed to allow accumulation, review and analysis of quality assurance (QA) data for measurement, treatment, imaging and simulation equipment in our department. Recording these data in a database allows a unified and structured approach to review and analysis of data gathered using commercial database tools. Methods: A clinical database was developed to track records of quality assurance operations on linear accelerators, a computed tomography (CT) scanner, high dose rate (HDR) afterloader and imaging systems such as on-board imaging (OBI) and Calypso in our department. The database was developed using Microsoft Access database and visual basic for applications (VBA) programming interface. Separate modules were written for accumulation, review and analysis of daily, monthly and annual QA data. All modules were designed to use structured query language (SQL) as the basis of data accumulation and review. The SQL strings are dynamically re-written at run time. The database also features embedded documentation, storage of documents produced during QA activities and the ability to annotate all data within the database. Tests are defined in a set of tables that define test type, specific value, and schedule. Results: Daily, Monthly and Annual QA data has been taken in parallel with established procedures to test MQA. The database has been used to aggregate data across machines to examine the consistency of machine parameters and operations within the clinic for several months. Conclusion: The MQA application has been developed as an interface to a commercially available SQL engine (JET 5.0) and a standard database back-end. The MQA system has been used for several months for routine data collection.. The system is robust, relatively simple to extend and can be migrated to a commercial SQL server.

60 APPLIED LIFE SCIENCES↗