Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “computed tomography”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

First Clinical Investigation of Cone Beam Computed Tomography and Deformable Registration for Adaptive Proton Therapy for Lung Cancer

Purpose: An adaptive proton therapy workflow using cone beam computed tomography (CBCT) is proposed. It consists of an online evaluation of a fast range-corrected dose distribution based on a virtual CT (vCT) scan. This can be followed by more accurate offline dose recalculation on the vCT scan, which can trigger a rescan CT (rCT) for replanning. Methods and Materials: The workflow was tested retrospectively for 20 consecutive lung cancer patients. A diffeomorphic Morphon algorithm was used to generate the lung vCT by deforming the average planning CT onto the CBCT scan. An additional correction step was applied to account for anatomic modifications that cannot be modeled by deformation alone. A set of clinical indicators for replanning were generated according to the water equivalent thickness (WET) and dose statistics and compared with those obtained on the rCT scan. The fast dose approximation consisted of warping the initial planned dose onto the vCT scan according to the changes in WET. The potential under- and over-ranges were assessed as a variation in WET at the target's distal surface. Results: The range-corrected dose from the vCT scan reproduced clinical indicators similar to those of the rCT scan. The workflow performed well under different clinical scenarios, including atelectasis, lung reinflation, and different types of tumor response. Between the vCT and rCT scans, we found a difference in the measured 95% percentile of the over-range distribution of 3.4 ± 2.7 mm. The limitations of the technique consisted of inherent uncertainties in deformable registration and the drawbacks of CBCT imaging. The correction step was adequate when gross errors occurred but could not recover subtle anatomic or density changes in tumors with complex topology. Conclusions: A proton therapy workflow based on CBCT provided clinical indicators similar to those using rCT for patients with lung cancer with considerable anatomic changes.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Observation of tilting activities in translated field reversed configuration plasma using computer tomography at two different cross sections

Tilting activities of field reversed configuration (FRC) plasma were observed in translation experiments using computer tomography (CT) at two different cross sections in the FRC injection experiment (FIX) machine [S. Okada et al., Nucl. Fusion 47, 677 (2007)]. In these experiments, two sets of CT devices were installed at the upstream and downstream sides of the confinement chamber of the FIX. Each CT device was composed of three arrays of detectors sensitive to the near-infrared radiation. The peak of the reconstructed emission profile at one side was displaced from the center of the cross section of the chamber. On the other hand, the reconstructed profile at the other side was located around the center. This result suggests that the FRC plasma was tilting in the axial direction. The occurrence of the observed tilting activities had almost no effect on the lifetime of the FRC plasma.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Note: Design and construction of a multi-scale, high-resolution, tube-generated X-Ray computed-tomography system for three-dimensional (3D) imaging

The design and construction of a high resolution modular x-ray computed tomography (XCT) system is described. The approach for meeting a specified set of performance goals tailored toward experimental versatility is highlighted. The instrument is unique in its detector and x-ray source configuration, both of which enable elevated optimization of spatial and temporal resolution. The process for component selection is provided. The selected components are specified, the custom component design discussed, and the integration of both into a fully functional XCT instrument is outlined. The novelty of this design is a new lab-scale detector and imaging optimization through x-ray source and detector modularity.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-D-12A-07: Optimization of a Moving Blocker System for Cone-Beam Computed Tomography Scatter Correction

Purpose: A moving blocker based strategy has shown promising results for scatter correction in cone-beam computed tomography (CBCT). Different parameters of the system design affect its performance in scatter estimation and image reconstruction accuracy. The goal of this work is to optimize the geometric design of the moving block system. Methods: In the moving blocker system, a blocker consisting of lead strips is inserted between the x-ray source and imaging object and moving back and forth along rotation axis during CBCT acquisition. CT image of an anthropomorphic pelvic phantom was used in the simulation study. Scatter signal was simulated by Monte Carlo calculation with various combinations of the lead strip width and the gap between neighboring lead strips, ranging from 4 mm to 80 mm (projected at the detector plane). Scatter signal in the unblocked region was estimated by cubic B-spline interpolation from the blocked region. Scatter estimation accuracy was quantified as relative root mean squared error by comparing the interpolated scatter to the Monte Carlo simulated scatter. CBCT was reconstructed by total variation minimization from the unblocked region, under various combinations of the lead strip width and gap. Reconstruction accuracy in each condition is quantified by CT number error as comparing to a CBCT reconstructed from unblocked full projection data. Results: Scatter estimation error varied from 0.5% to 2.6% as the lead strip width and the gap varied from 4mm to 80mm. CT number error in the reconstructed CBCT images varied from 12 to 44. Highest reconstruction accuracy is achieved when the blocker lead strip width is 8 mm and the gap is 48 mm. Conclusions: Accurate scatter estimation can be achieved in large range of combinations of lead strip width and gap. However, image reconstruction accuracy is greatly affected by the geometry design of the blocker.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

WE-G-207-03: Mask Guided Image Reconstruction (MGIR): A Novel Method for Ultra-Low-Dose 3D and Enhanced 4D Cone-Beam Computer-Tomography

Purpose: Recently, compressed sensing (CS) based iterative reconstruction (IR) method is receiving attentions to reconstruct high quality cone beam computed tomography (CBCT) images using sparsely sampled or noisy projections. The aim of this study is to develop a novel baseline algorithm called Mask Guided Image Reconstruction (MGIR), which can provide superior image quality for both low-dose 3DCBCT and 4DCBCT under single mathematical framework. Methods: In MGIR, the unknown CBCT volume was mathematically modeled as a combination of two regions where anatomical structures are 1) within the priori-defined mask and 2) outside the mask. Then we update each part of images alternatively thorough solving minimization problems based on CS type IR. For low-dose 3DCBCT, the former region is defined as the anatomically complex region where it is focused to preserve edge information while latter region is defined as contrast uniform, and hence aggressively updated to remove noise/artifact. In 4DCBCT, the regions are separated as the common static part and moving part. Then, static volume and moving volumes were updated with global and phase sorted projection respectively, to optimize the image quality of both moving and static part simultaneously. Results: Examination of MGIR algorithm showed that high quality of both low-dose 3DCBCT and 4DCBCT images can be reconstructed without compromising the image resolution and imaging dose or scanning time respectively. For low-dose 3DCBCT, a clinical viable and high resolution head-and-neck image can be obtained while cutting the dose by 83%. In 4DCBCT, excellent quality 4DCBCT images could be reconstructed while requiring no more projection data and imaging dose than a typical clinical 3DCBCT scan. Conclusion: The results shown that the image quality of MGIR was superior compared to other published CS based IR algorithms for both 4DCBCT and low-dose 3DCBCT. This makes our MGIR algorithm potentially useful in various on-line clinical applications. Provisional Patent: UF#15476; WGS Ref. No. U1198.70067US00.

60 APPLIED LIFE SCIENCES↗

MO-DE-207B-04: Impact of Reconstruction Field of View On Radiomics Features in Computed Tomography (CT) Using a Texture Phantom

Purpose: To investigate the impact of reconstruction Field of View on Radiomics features in computed tomography (CT) using a texture phantom. Methods: A rectangular Credence Cartridge Radiomics (CCR) phantom, composed of 10 different cartridges, was scanned on four different CT scanners from two manufacturers. A pre-defined scanning protocol was adopted for consistency. The slice thickness and reconstruction interval of 1.5 mm was used on all scanners. The reconstruction FOV was varied to result a voxel size ranging from 0.38 to 0.98 mm. A spherical region of interest (ROI) was contoured on the shredded rubber cartridge from CCR phantom CT scans. Ninety three Radiomics features were extracted from ROI using an in-house program. These include 10 shape, 22 intensity, 26 GLCM, 11 GLZSM, 11 RLM, 5 NGTDM and 8 fractal dimensional features. To evaluate the Interscanner variability across three scanners, a coefficient of variation (COV) was calculated for each feature group. Each group was further classified according to the COV by calculating the percentage of features in each of the following categories: COV≤ 5%, between 5 and 10% and ≥ 10%. Results: Shape features were the most robust, as expected, because of the spherical contouring of ROI. Intensity features were the second most robust with 54.5 to 64% of features with COV < 5%. GLCM features ranged from 31 to 35% for the same category. RLM features were sensitive to specific scanner and 5% variability was 9 to 54%. Almost all GLZM and NGTDM features showed COV ≥10% among the scanners. The dependence of fractal dimensions features on FOV was not consistent across different scanners. Conclusion: We concluded that reconstruction FOV greatly influence Radiomics features. The GLZSM and NGTDM are highly sensitive to FOV. funded in part by Grant NIH/NCI R01CA190105-01.

60 APPLIED LIFE SCIENCES↗

3D exemplar-based random walks for tooth segmentation from cone-beam computed tomography images

Purpose: Tooth segmentation is an essential step in acquiring patient-specific dental geometries from cone-beam computed tomography (CBCT) images. Tooth segmentation from CBCT images is still a challenging task considering the comparatively low image quality caused by the limited radiation dose, as well as structural ambiguities from intercuspation and nearby alveolar bones. The goal of this paper is to present and discuss the latest accomplishments in semisupervised tooth segmentation with adaptive 3D shape constraints. Methods: The authors propose a 3D exemplar-based random walk method of tooth segmentation from CBCT images. The proposed method integrates semisupervised label propagation and regularization by 3D exemplar registration. To begin with, the pure random walk method is to get an initial segmentation of the teeth, which tends to be erroneous because of the structural ambiguity of CBCT images. And then, as an iterative refinement, the authors conduct a regularization by using 3D exemplar registration, as well as label propagation by random walks with soft constraints, to improve the tooth segmentation. In the first stage of the iteration, 3D exemplars with well-defined topologies are adapted to fit the tooth contours, which are obtained from the random walks based segmentation. The soft constraints on voxel labeling are defined by shape-based foreground dentine probability acquired by the exemplar registration, as well as the appearance-based probability from a support vector machine (SVM) classifier. In the second stage, the labels of the volume-of-interest (VOI) are updated by the random walks with soft constraints. The two stages are optimized iteratively. Instead of the one-shot label propagation in the VOI, an iterative refinement process can achieve a reliable tooth segmentation by virtue of exemplar-based random walks with adaptive soft constraints. Results: The proposed method was applied for tooth segmentation of twenty clinically captured CBCT images. Three metrics, including the Dice similarity coefficient (DSC), the Jaccard similarity coefficient (JSC), and the mean surface deviation (MSD), were used to quantitatively analyze the segmentation of anterior teeth including incisors and canines, premolars, and molars. The segmentation of the anterior teeth achieved a DSC up to 98%, a JSC of 97%, and an MSD of 0.11 mm compared with manual segmentation. For the premolars, the average values of DSC, JSC, and MSD were 98%, 96%, and 0.12 mm, respectively. The proposed method yielded a DSC of 95%, a JSC of 89%, and an MSD of 0.26 mm for molars. Aside from the interactive definition of label priors by the user, automatic tooth segmentation can be achieved in an average of 1.18 min. Conclusions: The proposed technique enables an efficient and reliable tooth segmentation from CBCT images. This study makes it clinically practical to segment teeth from CBCT images, thus facilitating pre- and interoperative uses of dental morphologies in maxillofacial and orthodontic treatments.

60 APPLIED LIFE SCIENCES↗

X-ray Computed Tomography Imaging of Printed Circuit Boards

Nondestructive inspection of printed circuit boards (PCB) can be efficiently carried out with xray Computed Tomography (XCT). However, image artifacts can obscure some of the PCB details. As a demonstration of LLNL’s XCT capabilities, an internally-funded effort was recently executed that acquired XCT data for a PCB. These data were reconstructed with both traditional and physics-based iterative techniques to illustrate the use of advanced algorithms to reduce artifacts and thus improve image quality.

42 ENGINEERING↗

Computed Tomography Scanning and Geophysical Measurements of Appalachian Basin Core from the Jones and Laughlin #1 Well, Beaver County, PA

The computed tomography (CT) facilities and the Multi-Sensor Core Logger (MSCL) at the National Energy Technology Laboratory (NETL) in Morgantown, West Virginia, were used to characterize Appalachian Basin core from Beaver County, Pennsylvania. The primary impetus of this work is a collaboration between the U.S. Department of Energy (DOE) and the Pennsylvania Geological Survey to characterize and make publicly available core information from the Onondaga-Huntersville formations of the Appalachian Basin. This stratigraphic well and the core data produced in this report will aid in understanding the structural complexities of the Onondaga-Huntersville formations. The resultant datasets are presented in this report and can be accessed from NETL's Energy Data eXchange (EDX) online system using the following link: https://edx.netl.doe.gov/dataset/jonesandlaughlin1well. All equipment and techniques used were non-destructive, enabling future examinations and analyses to be performed on these cores. Fractures, discontinuities, and millimeter-scale features were readily detectable with imaging performed with the NETL medical CT scanner over the entire core. Qualitative analysis of the medical CT images, coupled with X-ray fluorescence (XRF), and magnetic susceptibility measurements from the MSCL were useful in identifying zones of interest for further study. Targeted higher resolution CT scanning of select sections was performed with NETL’s micro-CT scanner. The combination of methods used provides a multiscale analysis of the core; the resulting macro and micro descriptions are relevant to many subsurface energy related examinations traditionally performed at NETL.

58 GEOSCIENCES↗

Gold silver alloy nanoparticles (GSAN): an imaging probe for breast cancer screening with dual-energy mammography or computed tomography

Earlier detection of breast cancer reduces mortality from this disease. Thus, the development of better screening techniques is a topic of intense interest. Contrast-enhanced dual-energy mammography (DEM) is a novel technique that has improved sensitivity for cancer detection. However, the development of contrast agents for this technique is in its infancy. We herein report gold-silver alloy nanoparticles (GSAN) that have potent DEM contrast properties and improved biocompatibility. GSAN formulations containing a range of gold:silver ratios and capped with m-PEG were synthesized and characterized using various analytical methods. DEM and computed tomography (CT) phantom imaging showed that GSAN produced robust contrast that was comparable to silver alone. Cell viability, reactive oxygen species generation and DNA damage results revealed that the formulations with 30% or higher gold content are cytocompatible to Hep G2 and J774A.1 cells. In vivo imaging was performed in mice with and without breast tumors. The results showed that GSAN produce strong DEM and CT contrast and accumulated in tumors. Furthermore, both in vivo imaging and ex vivo analysis indicated the excretion of GSAN via both urine and feces. In summary, GSAN produce strong DEM and CT contrast, and has potential for both blood pool imaging and for breast cancer screening.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Neutron imaging with lithium indium diselenide: Surface properties, spatial resolution, and computed tomography

An array of lithium indium diselenide (LISe) scintillators were investigated for application in neutron imaging. The sensors, varying in thickness and surface roughness, were tested using both reflective and anti-reflective mounting to the aluminum window. The spatial resolution of each LISe scintillator was calculated using the knife-edge test and a modulation transfer function analysis. It was found that the anti-reflective backing yielded a significantly higher spatial resolution over the reflective backing, and in most cases far exceeded the spatial resolution of a 50 μm-thick ZnS(Cu): 6 LiF scintillation screen. Further, an apparent relationship between the observed increase in spatial resolution when using an anti-reflective backing and the quotient of the surface roughness to the thickness of the LISe scintillator was observed. Lastly, the LISe scintillator array was used in neutron computational tomography to investigate the features of halyomorpha halys.

36 MATERIALS SCIENCE↗

Accelerated radiation transport modeling techniques for pencil beam computed tomography using gamma rays

Monte Carlo radiation transport modeling studies were performed for a compact, and high-resolution gamma-ray computed tomography system designed for imaging irradiated nuclear fuel. The system comprises a 60 Co source – chosen for its highly penetrating 1173 keV and 1332 keV gamma rays – a pair of high-aspect-ratio pencil beam collimators, and an inorganic scintillator detector. Here two acceleration methods are proposed to rapidly model a transmission type gamma-ray tomography system. The first, a variance reduction technique, is based on performing Monte Carlo simulations with a monodirectionally-biased source, sampled from a characteristic sub-volume of the full source volume. The second acceleration method is based on the deterministic calculations using the Beer–Lambert law and detector response characteristics. Comparison of simulations using acceleration approaches with analog simulations of the fully isotropic, full-volume equivalent, show that the Monte Carlo variance reduction technique gives quantitatively accurate predictions for large collimator aspect ratios while the deterministic calculations are semi-quantitative but converge close to the correct result as the collimator aspect ratio increases. As such, these techniques can be used to reduce the computational cost in generating simulated radiographs and tomographs by several orders of magnitude. Experimental validation efforts are currently underway and will be demonstrated in future work.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Feasibility Study of Needle Placement in Percutaneous Vertebroplasty: Cone-Beam Computed Tomography Guidance Versus Conventional Fluoroscopy

ObjectiveTo investigate the accuracy, procedure time, fluoroscopy time, and dose area product (DAP) of needle placement during percutaneous vertebroplasty (PVP) using cone-beam computed tomography (CBCT) guidance versus fluoroscopy.Materials and MethodsOn 4 spine phantoms with 11 vertebrae (Th7-L5), 4 interventional radiologists (2 experienced with CBCT guidance and two inexperienced) punctured all vertebrae in a bipedicular fashion. Each side was randomization to either CBCT guidance or fluoroscopy. CBCT guidance is a sophisticated needle guidance technique using CBCT, navigation software, and real-time fluoroscopy. The placement of the needle had to be to a specific target point. After the procedure, CBCT was performed to determine the accuracy, procedure time, fluoroscopy time, and DAP. Analysis of the difference between methods and experience level was performed.ResultsMean accuracy using CBCT guidance (2.61 mm) was significantly better compared with fluoroscopy (5.86 mm) (p < 0.0001). Procedure time was in favor of fluoroscopy (7.39 vs. 10.13 min; p = 0.001). Fluoroscopy time during CBCT guidance was lower, but this difference is not significant (71.3 vs. 95.8 s; p = 0.056). DAP values for CBCT guidance and fluoroscopy were 514 and 174 mGy cm{sup 2}, respectively (p < 0.0001). There was a significant difference in favor of experienced CBCT guidance users regarding accuracy for both methods, procedure time of CBCT guidance, and added DAP values for fluoroscopy.ConclusionCBCT guidance allows users to perform PVP more accurately at the cost of higher patient dose and longer procedure time. Because procedural complications (e.g., cement leakage) are related to the accuracy of the needle placement, improvements in accuracy are clinically relevant. Training in CBCT guidance is essential to achieve greater accuracy and decrease procedure time/dose values.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Porous Iron Electrodes Reduce Energy Consumption During Electrocoagulation of a Virus Surrogate: Insights into Performance Enhancements Using Three-Dimensional Neutron Computed Tomography

Electrocoagulation has attracted significant attention as an alternative to conventional chemical coagulation because it is capable of removing a wide range of contaminants and has several potential advantages. In contrast to most electrocoagulation research that has been performed with nonporous electrodes, in this study, we demonstrate energy-efficient iron electrocoagulation using porous electrodes. In batch operation, investigation of the external pore structures through optical microscopy suggested that a low porosity electrode with sparse connection between pores may lead to mechanical failure of the pore network during electrolysis, whereas a high porosity electrode is vulnerable to pore clogging. Electrodes with intermediate porosity, instead, only suffered a moderate surface deposition, leading to electrical energy savings of 21% and 36% in terms of electrocoagulant delivery and unit log virus reduction, respectively. Neutron computed tomography revealed the critical role of electrode porosity in utilizing the electrode’s internal surface for electrodissolution and effective delivery of electrocoagulant to the bulk. Energy savings of up to 88% in short-term operation were obtained with porous electrodes in a continuous flow-through system. Further investigation on the impact of current density and porosity in long-term operation is desired as well as the capital cost of porous electrodes.

42 ENGINEERING↗

Micro X-ray computed tomography examination of mini plate fuel with hot isostatic pressed aluminum cladding

In order to minimize proliferation risks and improve security of nuclear material, the United States high performance research and test reactors (USHPRR) program is tasked with converting nuclear reactors that are fueled with highly enriched uranium (HEU) fuels to operate with low-enriched uranium (LEU) nuclear fuels. One favorable LEU fuel configuration is plate fuel with a metallic uranium-molybdenum foil clad within an aluminum alloy (AA 6061). In this fuel, the aluminum cladding is bonded with a hot isostatic pressing (HIP) method to seal the cladding around the fuel meat. However, the HIP process parameters influence the cladding performance, as a defective or incomplete bond can cause a pathway for corrosion. Micro X-ray computed tomography (XCT), a nondestructive technique that provides volumetric imaging, can be applied to inspect fuel plate cladding at the engineering scale. In this work, XCT methodology was developed and successfully utilized to not only observe the bond line of unirradiated mini fuel plates, but to also identify subsurface abnormalities in the plates’ cladding. Importantly, in future work, this technique could be applied to fuel plates, pre- and post-irradiation, to quantify irradiation effects on cladding defects and bond line integrity.

36 MATERIALS SCIENCE↗

Differentiation of aggressive from non-aggressive pancreatic solid pseudopapillary neoplasms using computed tomography

Purposes: Microscopic aggressive behaviors may be related with the prognosis of solid pseudopapillary neoplasms (SPNs). In this study, we investigate computed tomography (CT) features and differential diagnosis of aggressive and non-aggressive SPNs in pancreas. Materials and methods: 122 patients with pathologically proven SPNs in pancreas were included. Patients’ age, tumor site, texture, shape, margins, exophytic growth, capsule, calcification, hemorrhage, pancreatic duct dilatation or pancreatic parenchyma atrophy, peripancreatic infiltration or metastases, vascular encasement, and enhancement pattern were assessed. The diagnostic accuracy was analyzed by using the receiver operating characteristic curve (ROC). Results: There were 30 aggressive SPNs and 92 non-aggressive SPNs. Aggressive SPNs showed significantly higher frequencies of an ill-defined margin, patient age > 40.5 years, and tumor size < 42.1 mm, but lower frequencies of complete capsule, hemorrhage compared with non-aggressive SPNs (p < 0.05). Lack of complete capsule and age > 40.5 years were independent risk factors of aggressive SPNs (odd ratio 7.08 and 3.1, respectively). When we applied the two predictors in the logistic regression model, the area under the curve (AUC) was 0.77 with sensitivity of 86.7% and specificity of 55.4%. Conclusion: Size less than 42.1 mm, lack of complete capsule, ill-defined, and absent bleeding are useful CT imaging features for predicating aggressive SPNs. Patient age > 40.5 years and lack of complete capsule showed acceptable diagnostic performance for discriminating aggressive from non-aggressive SPNs.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Lung Tumors Treated With Percutaneous Radiofrequency Ablation: Computed Tomography Imaging Follow-Up

Purpose: To describe the morphologic evolution of lung tumors treated with radiofrequency ablation (RFA) by way of computed tomography (CT) images and to investigate patterns of incomplete RFA at the site of ablation. Materials and Methods: One hundred eighty-nine patients with 350 lung tumors treated with RFA underwent CT imaging at 2, 4, 6, and 12 months. CT findings were interpreted separately by two reviewers with consensus. Five different radiologic patterns were predefined: fibrosis, cavitation, nodule, atelectasis, and disappearance. The appearance of the treated area was evaluated at each follow-up CT using the predefined patterns. Results: At 1 year after treatment, the most common evolutions were fibrosis (50.5%) or nodules (44.8%). Differences were noted depending on the initial size of the tumor, with fibrosis occurring more frequently for tumors <2 cm (58.6% vs. 22.9%, P = 1 Multiplication-Sign 10{sup -5}). Cavitation and atelectasis were less frequent patterns (2.4% and 1.4%, respectively, at 1 year). Tumor location (intraparenchymatous, with pleural contact <50% or >50%) was not significantly correlated with follow-up image pattern. Local tumor progressions were observed with each type of evolution. At 1 year, 12 local recurrences were noted: 2 cavitations, which represented 40% of the cavitations noted at 1 year; 2 fibroses (1.9%); 7 nodules (7.4%); and 1 atelectasis (33.3%). Conclusion: After RFA of lung tumors, follow-up CT scans show that the shape of the treatment zone can evolve in five different patterns. None of these patterns, however, can confirm the absence of further local tumor progression at subsequent follow-up.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Megavoltage Computed Tomography Image Guidance With Helical Tomotherapy in Patients With Vertebral Tumors: Analysis of Factors Influencing Interobserver Variability

Purpose: To evaluate megavoltage computed tomography (MVCT)-based image guidance with helical tomotherapy in patients with vertebral tumors by analyzing factors influencing interobserver variability, considered as quality criterion of image guidance. Methods and Materials: Five radiation oncologists retrospectively registered 103 MVCTs in 10 patients to planning kilovoltage CTs by rigid transformations in 4 df. Interobserver variabilities were quantified using the standard deviations (SDs) of the distributions of the correction vector components about the observers' fraction mean. To assess intraobserver variabilities, registrations were repeated after {>=}4 weeks. Residual deviations after setup correction due to uncorrectable rotational errors and elastic deformations were determined at 3 craniocaudal target positions. To differentiate observer-related variations in minimizing these residual deviations across the 3-dimensional MVCT from image resolution effects, 2-dimensional registrations were performed in 30 single transverse and sagittal MVCT slices. Axial and longitudinal MVCT image resolutions were quantified. For comparison, image resolution of kilovoltage cone-beam CTs (CBCTs) and interobserver variability in registrations of 43 CBCTs were determined. Results: Axial MVCT image resolution is 3.9 lp/cm. Longitudinal MVCT resolution amounts to 6.3 mm, assessed as full-width at half-maximum of thin objects in MVCTs with finest pitch. Longitudinal CBCT resolution is better (full-width at half-maximum, 2.5 mm for CBCTs with 1-mm slices). In MVCT registrations, interobserver variability in the craniocaudal direction (SD 1.23 mm) is significantly larger than in the lateral and ventrodorsal directions (SD 0.84 and 0.91 mm, respectively) and significantly larger compared with CBCT alignments (SD 1.04 mm). Intraobserver variabilities are significantly smaller than corresponding interobserver variabilities (variance ratio [VR] 1.8-3.1). Compared with 3-dimensional registrations, 2-dimensional registrations have significantly smaller interobserver variability in the lateral and ventrodorsal directions (VR 3.8 and 2.8, respectively) but not in the craniocaudal direction (VR 0.75). Conclusion: Tomotherapy image guidance precision is affected by image resolution and residual deviations after setup correction. Eliminating the effect of residual deviations yields small interobserver variabilities with submillimeter precision in the axial plane. In contrast, interobserver variability in the craniocaudal direction is dominated by the poorer longitudinal MVCT image resolution. Residual deviations after image guidance exist and need to be considered when dose gradients ultimately achievable with image guided radiation therapy techniques are analyzed.

62 RADIOLOGY AND NUCLEAR MEDICINE↗