Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “compositional noise”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

Development of an Active Twist Rotor for Wind: Tunnel Testing (NLPN97-310

The development of the Active Twist Rotor prototype blade for hub vibration and noise reduction studies is presented in this report. Details of the modeling, design, and manufacturing are explored. The rotor blade is integrally twisted by direct strain actuation. This is accomplished by distributing embedded piezoelectric fiber composites along the span of the blade. The development of the analysis framework for this type of active blade is presented. The requirements for the prototype blade, along with the final design results are also presented. A detail discussion on the manufacturing aspects of the prototype blade is described. Experimental structural characteristics of the prototype blade compare well with design goals, and preliminary bench actuation tests show lower performance than originally predicted. Electrical difficulties with the actuators are also discussed. The presented prototype blade is leading to a complete fully articulated four-blade active twist rotor system for future wind tunnel tests.

Cesnik, Carlos E. S.↗

Development and Validation of an Interactive Liner Design and Impedance Modeling Tool

The Interactive Liner Impedance Analysis and Design (ILIAD) tool is a LabVIEW-based software package used to design the composite surface impedance of a series of small-diameter quarter-wavelength resonators incorporating variable depth and sharp bends. Such structures are useful for packaging broadband acoustic liners into constrained spaces for turbofan engine noise control applications. ILIAD s graphical user interface allows the acoustic channel geometry to be drawn in the liner volume while the surface impedance and absorption coefficient calculations are updated in real-time. A one-dimensional transmission line model serves as the basis for the impedance calculation and can be applied to many liner configurations. Experimentally, tonal and broadband acoustic data were acquired in the NASA Langley Normal Incidence Tube over the frequency range of 500 to 3000 Hz at 120 and 140 dB SPL. Normalized impedance spectra were measured using the Two-Microphone Method for the various combinations of channel configurations. Comparisons between the computed and measured impedances show excellent agreement for broadband liners comprised of multiple, variable-depth channels. The software can be used to design arrays of resonators that can be packaged into complex geometries heretofore unsuitable for effective acoustic treatment.

Howerton, Brian M.↗

NEW CONSTRAINTS ON THE QUASAR BROAD EMISSION LINE REGION

We demonstrate a new technique for determining the physical conditions of the broad-line-emitting gas in quasars, using near-infrared hydrogen emission lines. Unlike higher ionization species, hydrogen is an efficient line emitter for a very wide range of photoionization conditions, and the observed line ratios depend strongly on the density and photoionization state of the gas present. A locally optimally emitting cloud model of the broad emission line region was compared to measured emission lines of four nearby (z Almost-Equal-To 0.2) quasars that have optical and NIR spectra of sufficient signal to noise to measure their Paschen lines. The model provides a good fit to three of the objects, and a fair fit to the fourth object, an ultraluminous infrared galaxy. We find that low-incident-ionizing fluxes ({Phi}{sub H} < 10{sup 18} cm{sup -2} s{sup -1}) and high gas densities (n{sub H} > 10{sup 12} cm{sup -3}) are required to reproduce the observed hydrogen emission line ratios. This analysis demonstrates that the use of composite spectra in photoionization modeling is inappropriate; models must be fitted to the individual spectra of quasars.

79 ASTRONOMY AND ASTROPHYSICS↗

Challenges and Capabilities for Inspection of Cast Stainless Steel Piping

Studies conducted at the Pacific N¬orthwest National Laboratory (PNNL) in Richland, Washington, have focused on developing and evaluating the reliability of nondestructive examination (NDE) approaches for inspecting coarse-grained, cast stainless steel reactor components. The objective of this work is to provide information to the United States Nuclear Regulatory Commission (US NRC) on the utility, effec¬tiveness and limitations of NDE techniques as related to the inservice inspec¬tion of primary system piping components in pressurized water reactors (PWRs). This paper describes results from recent assessments built upon early work with low frequency ultrasonic testing (UT) coupled with synthetic aperture focusing technique (SAFT) signal processing, and has subsequently evolved into an approach using low frequency phased array technology as applied from the outer diameter surface of the piping. In addition, eddy current examination as performed from the inner diameter surface of these piping welds is also reported. Cast stainless steel (CSS) pipe specimens were examined that contain thermal and mechanical fatigue cracks located close to the weld roots and have inside/outside surface geometrical conditions that simulate several PWR primary piping weldments and configurations. In addition, segments of vintage centrifugally cast piping were also examined to understand inherent acoustic noise and scattering due to grain structures and determine consistency of UT responses from different locations. The advanced UT methods were applied from the outside surface of these specimens using automated scanning devices and water coupling. The phased array approach was implemented with a modified instrument operating at low frequencies and composite volumetric images of the samples were generated with 500 kHz, 750 kHz, and 1.0 MHz arrays. Eddy current studies were conducted on the inner diameter surface of these piping welds using a commercially available instrument and a cross point probe design operating at a frequency of 250 kHz. Results from the laboratory studies indicate that 500 kHz phased array methods are capable of detecting flaws greater than 30% through-wall in the cast specimens. Length-sizing of flaws is possible, but no diffracted signals could be observed to support time-of-flight depth sizing. The work with eddy current examinations on the inner diameter surface indicate that, while certain cast austenitic microstructures provide excessive background noise due to permeability variations, surface-breaking flaws are quite easily detected. This work was sponsored by the U.S. Nuclear Regulatory Commission under Contract DE-AC06-76RLO 1830; NRC JCN Y6604; Mr. Wallace Norris, NRC Project Monitor.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Bowtie filters for dedicated breast CT: Theory and computational implementation

Purpose: To design bowtie filters with improved properties for dedicated breast CT to improve image quality and reduce dose to the patient. Methods: The authors present three different bowtie filters designed for a cylindrical 14-cm diameter phantom with a uniform composition of 40/60 breast tissue, which vary in their design objectives and performance improvements. Bowtie design #1 is based on single material spectral matching and produces nearly uniform spectral shape for radiation incident upon the detector. Bowtie design #2 uses the idea of basis material decomposition to produce the same spectral shape and intensity at the detector, using two different materials. Bowtie design #3 eliminates the beam hardening effect in the reconstructed image by adjusting the bowtie filter thickness so that the effective attenuation coefficient for every ray is the same. All three designs are obtained using analytical computational methods and linear attenuation coefficients. Thus, the designs do not take into account the effects of scatter. The authors considered this to be a reasonable approach to the filter design problem since the use of Monte Carlo methods would have been computationally intensive. The filter profiles for a cone-angle of 0° were used for the entire length of each filter because the differences between those profiles and the correct cone-beam profiles for the cone angles in our system are very small, and the constant profiles allowed construction of the filters with the facilities available to us. For evaluation of the filters, we used Monte Carlo simulation techniques and the full cone-beam geometry. Images were generated with and without each bowtie filter to analyze the effect on dose distribution, noise uniformity, and contrast-to-noise ratio (CNR) homogeneity. Line profiles through the reconstructed images generated from the simulated projection images were also used as validation for the filter designs. Results: Examples of the three designs are presented. Initial verification of performance of the designs was done using analytical computations of HVL, intensity, and effective attenuation coefficient behind the phantom as a function of fan-angle with a cone-angle of 0°. The performance of the designs depends only weakly on incident spectrum and tissue composition. For all designs, the dynamic range requirement on the detector was reduced compared to the no-bowtie-filter case. Further verification of the filter designs was achieved through analysis of reconstructed images from simulations. Simulation data also showed that the use of our bowtie filters can reduce peripheral dose to the breast by 61% and provide uniform noise and CNR distributions. The bowtie filter design concepts validated in this work were then used to create a computational realization of a 3D anthropomorphic bowtie filter capable of achieving a constant effective attenuation coefficient behind the entire field-of-view of an anthropomorphic breast phantom. Conclusions: Three different bowtie filter designs that vary in performance improvements were described and evaluated using computational and simulation techniques. Results indicate that the designs are robust against variations in breast diameter, breast composition, and tube voltage, and that the use of these filters can reduce patient dose and improve image quality compared to the no-bowtie-filter case.

60 APPLIED LIFE SCIENCES↗

MULTI-EPOCH OBSERVATIONS OF HD 69830: HIGH-RESOLUTION SPECTROSCOPY AND LIMITS TO VARIABILITY

The main-sequence solar-type star HD 69830 has an unusually large amount of dusty debris orbiting close to three planets found via the radial velocity technique. In order to explore the dynamical interaction between the dust and planets, we have performed multi-epoch photometry and spectroscopy of the system over several orbits of the outer dust. We find no evidence for changes in either the dust amount or its composition, with upper limits of 5%-7% (1{sigma} per spectral element) on the variability of the dust spectrum over 1 year, 3.3% (1{sigma}) on the broadband disk emission over 4 years, and 33% (1{sigma}) on the broadband disk emission over 24 years. Detailed modeling of the spectrum of the emitting dust indicates that the dust is located outside of the orbits of the three planets and has a composition similar to main-belt, C-type asteroids in our solar system. Additionally, we find no evidence for a wide variety of gas species associated with the dust. Our new higher signal-to-noise spectra do not confirm our previously claimed detection of H{sub 2}O ice leading to a firm conclusion that the debris can be associated with the break-up of one or more C-type asteroids formed in the dry, inner regions of the protoplanetary disk of the HD 69830 system. The modeling of the spectral energy distribution and high spatial resolution observations in the mid-infrared are consistent with a {approx}1 AU location for the emitting material.

79 ASTRONOMY AND ASTROPHYSICS↗

Growth and characterization of large (Y,La)TiO 3 and (Y,Ca)TiO 3 single crystals

The Mott-insulating rare-earth titanates ( R TiO 3 , with R being a rare-earth ion) are an important class of materials that encompasses interesting spin-orbital phases as well as ferromagnet-antiferromagnet and insulator-metal transitions. The growth of these materials has been plagued by difficulties related to overoxidation, which arises from a strong tendency of Ti 3 + to oxidize to Ti 4 + . We describe our efforts to grow sizable single crystals of YTiO 3 , Y 1 - x La x TiO 3 ( x ≤ 0.25 ), and Y 1 - y Ca y TiO 3 ( y ≤ 0.35 ) with the optical traveling-solvent floating-zone technique. Finally, we present sample characterization via chemical composition analysis, magnetometry, charge transport, neutron scattering, x-ray absorption spectroscopy, and x-ray magnetic circular dichroism to understand macroscopic physical property variations associated with overoxidation. Furthermore, we demonstrate a good signal-to-noise ratio in inelastic magnetic neutron scattering measurements of spin-wave excitations. A superconducting impurity phase, found to appear in Ca-doped samples at high doping levels, is identified as TiO.

36 MATERIALS SCIENCE↗

Image quality comparison between single energy and dual energy CT protocols for hepatic imaging

Purpose: Multi-detector computed tomography (MDCT) enables volumetric scans in a single breath hold and is clinically useful for hepatic imaging. For simple tasks, conventional single energy (SE) computed tomography (CT) images acquired at the optimal tube potential are known to have better quality than dual energy (DE) blended images. However, liver imaging is complex and often requires imaging of both structures containing iodinated contrast media, where atomic number differences are the primary contrast mechanism, and other structures, where density differences are the primary contrast mechanism. Hence it is conceivable that the broad spectrum used in a dual energy acquisition may be an advantage. In this work we are interested in comparing these two imaging strategies at equal-dose and more complex settings. Methods: We developed numerical anthropomorphic phantoms to mimic realistic clinical CT scans for medium size and large size patients. MDCT images based on the defined phantoms were simulated using various SE and DE protocols at pre- and post-contrast stages. For SE CT, images from 60 kVp through 140 with 10 kVp steps were considered; for DE CT, both 80/140 and 100/140 kVp scans were simulated and linearly blended at the optimal weights. To make a fair comparison, the mAs of each scan was adjusted to match the reference radiation dose (120 kVp, 200 mAs for medium size patients and 140 kVp, 400 mAs for large size patients). Contrast-to-noise ratio (CNR) of liver against other soft tissues was used to evaluate and compare the SE and DE protocols, and multiple pre- and post-contrasted liver-tissue pairs were used to define a composite CNR. To help validate the simulation results, we conducted a small clinical study. Eighty-five 120 kVp images and 81 blended 80/140 kVp images were collected and compared through both quantitative image quality analysis and an observer study. Results: In the simulation study, we found that the CNR of pre-contrast SE image mostly increased with increasing kVp while for post-contrast imaging 90 kVp or lower yielded higher CNR images, depending on the differential iodine concentration of each tissue. Similar trends were seen in DE blended CNR and those from SE protocols. In the presence of differential iodine concentration (i.e., post-contrast), the CNR curves maximize at lower kVps (80–120), with the peak shifted rightward for larger patients. The combined pre- and post-contrast composite CNR study demonstrated that an optimal SE protocol has better performance than blended DE images, and the optimal tube potential for SE scan is around 90 kVp for a medium size patients and between 90 and 120 kVp for large size patients (although low kVp imaging requires high x-ray tube power to avoid photon starvation). Also, a tin filter added to the high kVp beam is not only beneficial for material decomposition but it improves the CNR of the DE blended images as well. The dose adjusted CNR of the clinical images also showed the same trend and radiologists favored the SE scans over blended DE images. Conclusions: Our simulation showed that an optimized SE protocol produces up to 5% higher CNR for a range of clinical tasks. The clinical study also suggested 120 kVp SE scans have better image quality than blended DE images. Hence, blended DE images do not have a fundamental CNR advantage over optimized SE images.

60 APPLIED LIFE SCIENCES↗

Thermal ion heating in the vicinity of the plasmapause: A Dynamics Explorer guest investigation

The ion thermal structure of the plasmasphere was investigated in a series of experiments. It appears that energy may be generally available to ion and electrons in the vinicity of the plasmapause from Coulomb interactions between ambient thermal plasma and low energy ring current and suprathermal ions, particularly O+. The amount of energy transferred depends on the densities and energies of each of the components. The spatial distribution of heating in turn depends critically on the spatial distribution of the different populations, especially on the density gradients. The spatial distribution of the thermal plasma is found to vary significantly on a diurnal time scale and is complicated by the plasmasphere erosion and refilling processes associated with magnetic activity and its aftermath. Thermal ion composition also appears to be influenced by the heating taking place, often increasing the heavy ion population in the vicinity of the plasmapause. The observations of equatorial heating near the plasmapause in the presence of equatorial noise also raise the likelihood of a wave source of energy. It is not unreasonable to expect that both particle and wave heat sources are significant, although not necessarily at the same times and places.

Comfort, R. H.↗

Frequency stability of GPS NAVSTAR block 1 and block 2 on-orbit clocks

Analysis of the frequency stability of the on-orbit NAVSTAR clocks os performed by the Naval Research Laboratory. The frequency stability is presented for sample times of one day to 30 days. Composite frequency stability profiles are presented for Block 1 and Block 2 NAVSTAR clocks. Several NAVSTAR cesium clocks show frequency stabilities of a few parts in 10^(14) for long sample times. Time-domain noise-process analysis shows the dominant noise type to be white frequency noise for sample times of one to ten days. The non-stationary stochastic behavior of one of the cesium clocks, illustrated by its frequency stability history, shows that the frequency stability is not always time-invariant.

Thomas B. Mccaskill↗

MinMap: An imaging spectrometer for high resolution compositional mapping of the Moon

MinMap has been selected by the Lunar Scout program to characterize and map the mineral composition of the Moon. The instrument will be built as a collaborative effort between Brown University, SETS Technology Inc., and Ball Aerospace Corp. MinMap is a visible to near-infrared imaging spectrometer that contains 192 spectral channels from 0.35-2.4 microns with signal to noise greater than 200 and 256 cross-track spatial elements. The spectrometer design has a 6 deg field of view (FOV) and utilizes grating dispersive elements and two dimensional detectors (no moving parts). An 'image cube' of data is produced that contains two dimensions of spatial information and one dimension of spectral information. All spectral channels and cross-track spatial elements are recorded simultaneously with spacecraft motion scanning the second spatial dimension. The high spectral resolution and continuous spectral range of MinMap are designed to measure the diagnostic absorption features of principal lunar minerals and their lithologic mixtures. Since the optical properties of lunar materials change in a regular manner upon exposure to the space environment, this spectral range is also quite sensitive to variations in exposure history (soil maturity). Nominal measurement stragegy is to obtain full global data of the Moon at 180 m/pixel from a 450 km polar orbit during the first month or two of operation. A 100 km orbit is anticipated for the remaining part of a 1 year mission allowing higher resolution data (approx. 80 m/pixel) to be obtained for targeted regions. MinMap exceeds LE x SWG's measurement recommendations and will provide the highest spatial resolution compositional map of lunar rocks and soils currently planned for orbital missions. Since all spectral channels are co-registered and obtained simultaneously, 'image cube' data swaths will be available for analysis almost immediately.

Pieters, C. M.↗

Neutral red interlinked gold nanoparticles/multiwalled carbon nanotubes hybrid nanomaterial and its application for the detection of NADH

Graphical abstract: - Highlights: • Fabricated a nanostructured hybrid material of GNPs/neutral red/MWCNTs. • GNPs decorated on MWCNT template by using neutral red as interlinker for first time. • Nanocomposite modified electrode employed successfully as sensor for NADH. • The electrode has high stability as it does not involve any biological entity. - Abstract: A novel nanocomposite of gold nanoparticles/neutral red/MWCNTs was prepared which was used to modify glassy carbon electrode. The prepared nanocomposite was physically characterized by scanning electron microscopy, transmission electron microscopy, zeta potential measurement, energy dispersive X-ray, FTIR spectroscopy, UV–visible spectroscopy. Electrochemical characterization was done using cyclic voltammetry technique. The modified glassy carbon electrode showed electrocatalytic activity toward the oxidation of NADH in 0.1 M phosphate buffer solution, pH 5.0. The modified electrode has better adhesion over the electrode surface, good stability as no leaching of neutral red based nanocomposite was observed. The oxidation of NADH started at 0.37 V and reached maxima at 0.52 V at the modified electrode surface. So the prepared composite modified electrode can be applied as electrochemical sensor for NADH. The sensitivity and detection limits of the modified glassy carbon electrode were found to be 0.588 μA/mM and 5 × 10{sup −7} at signal to noise ratio 3.

36 MATERIALS SCIENCE↗

Selecting a composite correlation filter design: a survey and comparative study

Many composite correlation filter designs have been proposed for solving a wide variety of target detection and pattern recognition problems. Due to the large number of available designs, however, it is often unclear how to select the best design for a particular application. We present a theoretical survey and an empirical comparison of several popular composite correlation filter designs. Using a database of rotational target imagery, we show that some such filter designs appear to be better choices than others under computational and performance constraints. We compare filter performance in terms of noise tolerance, computational load, generalization ability, and distortion in order to provide a multifaceted examination of the characteristics of various filter designs.

42 ENGINEERING↗

Nondetection of Helium in the Upper Atmospheres of Three Sub-Neptune Exoplanets

We present a search for helium in the upper atmospheres of three sub-Neptune-sized planets to investigate the origins of these ubiquitous objects. The detection of helium for a low-density planet would be strong evidence for the presence of a primary atmosphere accreted from the protoplanetary nebula because large amounts of helium are not expected in the secondary atmospheres of rocky planets. We used Keck+NIRSPEC to obtain high-resolution transit spectroscopy of the planets GJ 1214b, GJ 9827d, and HD 97658b around the 10833 Å He triplet feature. We did not detect helium absorption for any of the planets despite achieving a high level of sensitivity. We used the nondetections to set limits on the planets’ thermosphere temperatures and atmospheric loss rates by comparing grids of 1D models to the data. We also performed coupled interior structure and atmospheric loss calculations, which suggest that the bulk atmospheres (winds) of the planets would be at most modestly enhanced (depleted) in helium relative to their primordial composition. Our lack of detections of the helium triplet for GJ 1214b and GJ 9827d is highly inconsistent with the predictions of models for the present-day mass loss on these planets. Higher signal-to-noise data would be needed to detect the helium feature predicted for HD 97658b. We identify uncertainties in the extreme-ultraviolet fluxes of the host stars and the lack of detailed mass-loss models specifically for cool and metal-enhanced atmospheres as the main limitations to the interpretation of our results. Ultimately, our results suggest that the upper atmospheres of sub-Neptune planets are fundamentally different from those of gas giant planets.

79 ASTRONOMY AND ASTROPHYSICS↗

Lightweight Ceramics for Aeroacoustic Applications

The use of a HTP (High Temperature Performance) ceramic foam for aeroacoustic applications is investigated. HTP ceramic foam is a composition of silica and alumina fibers developed by LMMS. This foam is a lightweight high-temperature fibrous bulk material with small pore size, ultra high porosity, and good strength. It can be used as a broadband noise absorber at both room and high temperature (up to 1800 F). The investigation included an acoustic assessment as well as material development, and environmental and structural evaluations. The results show that the HTP ceramic foam provides good broadband noise absorbing capability and adequate strength when incorporating the HTP ceramic foam system into a honeycomb sandwich structure. On the other hand, the material is sensitive to Skydrol and requires further improvements. Good progress has been made in the impedance model development. A relationship between HTP foam density, flow resistance, and tortuosity will be established in the near future. Additional effort is needed to investigate the coupling effects between face sheet and HTP foam material.

Kwan, H. W.↗

Detection of CH 4 Hotspots from NASA’s GEOS Composition Analysis System

Recent research indicates that 8 to 12% of the global oil and gas production methane emissions could be attributed to ultra-emitters, which result in high concentration ‘hotspots’ near point sources. Identifying these emissions in near real time provides useful information to the policy makers and private industry, who are working to reduce their impact. To meet this need, scientists are increasingly analyzing satellite data from the TROPOspheric Monitoring Instrument (TROPOMI) instrument aboard ESA’s Sentinel 5-Precursor mission. While direct analysis of TROPOMI level 2 swath data has been successful in identifying some large emission events, identifying hotpots is challenging because of the imaging noise due to a variety of artifacts and limits in daily coverage. Here we explore possible methodologies to detect methane hotspots using a new, gap-filled, and temporally continuous methane product from NASA’s Goddard Earth Observing System (GEOS) Constituent Data Assimilation System (CoDAS), which assimilates column averaged methane mole fractions from the TROPOMI with capabilities to assimilate other remote sensing measurements. The CoDAS has been expanded from a heritage of stratospheric composition and carbon dioxide assimilation allowing for the support of regional modeling, validation with non-coincident operations, and merging variety of datasets. The current work mainly explores Observing System Simulation Experiments with methane GEOS simulations without assimilation to prepare the groundwork for further experiments with assimilated TROPOMI. First, known hotspots based on the known inventory are identified to demonstrate the capability of the system to point out emission hotspots. In the next step, a variety of machine learning techniques such as Self-Organizing Maps and Deep Learning are explored to automate detection of the plumes. Finally, a few approaches to quantify emissions from the identified hotspots are presented and are evaluated against the inventory. The effort is directed toward a future evaluation of the CoDAS based methane monitoring system’s ability to successfully detect and quantify hotspots.

Nikolay Balashov↗

Influence of Atmospheric Pressure and Composition on LIBS

Most LIBS experiments are conducted at standard atmospheric pressure in air. However, there are LIBS studies that vary the pressure and composition of the gas. These studies have provided insights into fundamentals of the mechanisms that lead to the emission and methods for improving the quality of LIBS spectra. These atmospheric studies are difficult because the effects of pressure and gas composition and interconnected, making interpretation of the results difficult. The influence of pressures below and above 760 Torr have been explored. Performing LIBS on a surface at reduced pressures (<760 Torr) can result in enhanced spectra due to higher resolution, increased intensity, improved signal-to-noise (S/N), and increased ablation. Lower pressures produce increased resolution because the line width in LIBS spectra is predominantly due to Stark and Doppler broadening. Stark broadening is primarily caused from collisions between electrons and atoms, while Doppler broadening is proportional to the plasma temperature. Close examination using a high resolution spectrometer reveals that spectra show significant peak broadening and self-absorption as pressures increase, especially for pressures >760 Torr. During LIBS plasma expansion, energy is lost to the surrounding atmosphere, which reduces the lifetime of the laser plasma. Therefore, reducing the pressure increases the lifetime of the plasma, allowing more light from the laser plasma to be collected; thus, increasing the observed signal intensity. However, if pressures are too low (<10 Torr), then there is a steep drop in LIBS spectral intensity. This loss in intensity is mostly due to a disordered plasma that results from the lack of sufficient atmosphere to provide adequate confinement. At reduced pressures, the plasma expands into a less dense atmosphere, which results in a less dense shock wave. The reduced density in the shock wave results in reduced plasma shielding, allowing more photons to reach the sample. Increasing the number of photons interacting with the sample surface results in increased ablation, which can lead to increased intensity. The composition of the background gas has been shown to greatly influence the observed LIBS spectra by altering the plasma temperature, electron density, mass removal, and plasma shielding that impact the emission intensity and peak resolution. It has been reported that atmospheric Ar results in the highest plasma temperature and electron density, while a He atmosphere results in the lowest plasma temperatures and electron density. Studying temporal data, it was also found that Ar had the slowest decay of both electron density and plasma temperature, while He had the fastest decay in both parameters. The higher plasma temperature and electron density results in an increase in line broadenin, or poor resolution, for Ar compared to He. A rapidly developing LIBS plasma with a sufficient amount of electrons can absorb a significant portion of the laser pulse through inverse Bremsstahlung. Ar (15.8 eV ) is more easily ionized than He (24.4 eV). The breakdown threshold for He at 760 Torr is approximately 3 times greater than Ar and approximately 5 times greater at 100 Torr. The lower breakdown threshold in Ar, compared to He, creates an environment favorable for plasma shielding, which reduces sample vaporization and leads to a weaker LIBS signal.

36 MATERIALS SCIENCE↗

Preparation and Characterization of Silanes Films to Protect Electrogalvanized Steel

Silanes are an interesting alternative to chromate-based surface treatments for temporary protection of electrogalvanized steel. In this work, the protective behavior of 3-mercaptopropyltrimethoxysilane (MTMO), 3-aminopropyltriethoxysilane (AMEO), or 3-glycidoxypropyltrimethoxysilane (GLYMO) films applied on electrogalvanized automotive quality steel sheets has been studied. The silane coating morphology, composition, and porosity were characterized by scanning electron microscopy (SEM), energy-dispersive x-ray spectroscopy (EDS), x-ray fluorescence, immersion in copper sulfate, and cyclic voltammetry. The corrosion protection was evaluated by polarization curves, electrochemical noise measurements, electrochemical impedance spectrometry, and accelerated humidity chamber tests. The results showed that the silanes protect temporarily electrogalvanized steel from corrosion. MTMO forms a relatively thick and cracked film. AMEO and GLYMO films were so thin that they could not be observed by SEM but silicon was detected by EDS. MTMO provided good temporary protection, being an alternative to replace Cr(VI) as protector of electrogalvanized steel.

36 MATERIALS SCIENCE↗