Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “coils”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

Inductive circuit sensor system and method

An inductive circuit sensor system and method for monitoring an electromagnetic signal path through a circuit is shown. A protected element or door is movably positionable adjacent to the stationary element or frame in a monitored position. A conductive sensor pattern element is connected to a pair of inductive coils. The pattern element is a conductive wire traversing a predetermined cross-section of the door. The frame has a transmitting coil in communication with a microcontroller. The transmitting coil is coupled with the first coil and a receiving coil is coupled with the second coil. The transmitting coil receives a signal from the microcontroller and couples the signal to the pattern element. The signal is in communication with a receiving port on the microcontroller. The microcontroller is programmed to compare the signal from the transmit port with the signal at the receiving port.

Neidigk, Stephen↗

Wireless power transfer to biomedical implants

Various examples are provided for wireless power transfer to implants. In one example, a system includes a radio frequency (RF) power source and a transmitter (TX) array comprising an excitation coil and resonant coils distributed about the excitation coil. The TX array can transfer power from the RF power source to a biomedical implant inserted below a skin surface of a subject when the TX array is positioned on the skin surface adjacent to the biomedical implant. A receiver (RX) coil of the biomedical implant can inductively couple with the TX array for the power. The resonant coils can allow power transfer when the RX coil is not aligned with the excitation coil.

Lin, Jenshan↗

Wireless power transfer to biomedical implants

Various examples are provided for wireless power transfer to implants. In one example, a system includes a radio frequency (RF) power source and a transmitter (TX) array comprising an excitation coil and resonant coils distributed about the excitation coil. The TX array can transfer power from the RF power source to a biomedical implant inserted below a skin surface of a subject when the TX array is positioned on the skin surface adjacent to the biomedical implant. A receiver (RX) coil of the biomedical implant can inductively couple with the TX array for the power transfer. The resonant coils can allow power transfer when the RX coil is not aligned with the excitation coil.

Lin, Jenshan↗

Designing stellarators using perpendicular permanent magnets

We have developed a fast method to design perpendicular permanent magnets for simplifying stellarator coils based on existing codes. Coil complexity is one of the main challenges for stellarators. To date, only electromagnetic coils have been used to generate 3D fields for stellarators. Permanent magnets provide an alternative way to produce the desired magnetic field for optimized stellarators. In this paper, we revisit the concept of representing surface current using magnetic dipoles and carry out numerical validations. A surface magnetization is proven to be equivalent to the surface current that can be linearly solved by existing coil design codes. An incremental multi-layer method has been developed to obtain a practical solution that is attainable with present permanent magnets. With this method, we can reproduce a half-Tesla NCSX configuration using specially designed neodymium magnets together with simple planar coils. It shows that stellarator coils could be substantially simplified by adopting permanent magnets.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Recent Progress of JT-60SA Project toward Plasma Operation

Superconducting tokamak JT-60SA plays an essential role in fusion research and development by supporting and complementing ITER project, providing directions to the DEMO design activity and fostering next generation scientists and engineers. Since the incident of the Equilibrium Field coil #1 during the Integrated Commissioning (IC) in March 2021, both EU and JA Implementing agencies (IAs) have examined how to ensure safety operation of JT-60SA by mitigating the risk of possible discharge occurrence inside the cryostat. Based on the experience of the Global Paschen tests, the IAs have established a strategy of risk mitigation measures, which is a combination of (i) reinforcement of insulation, (ii) avoiding unnecessary voltage application to the coil systems and (iii) immediate de-energization of the coils when deteriorated vacuum condition is detected. Thanks to the considerable efforts of the Integrated Project Team (IPT) members, the IC restarted in May 2023. After the confirmation of superconducting state of coil systems (TF, EF and CS), the coil energization test and the plasma operation (OP-1) starts. The first plasma was successfully achieved on 23 October 2023 with a limited value of applied voltage and current to the coils. The plasma configuration control will be also confirmed with low plasma current and low auxiliary heating power conditions. Based on the IO-F4E-QST collaboration, activities of JT-60SA have been shared with the IO and provided an important lesson learned for ITER assembly and commissioning, and will provide an outstanding contribution to fusion research at large. After OP-1, Maintenance & Enhancement phase 1 (M/E-1) starts from January 2024, in which in-vessel components are installed, and heating system and diagnostic system are extensively upgraded to allow high power heating experiment planned in OP-2. In order to make the best use of JT-60SA, newly organized JT-60SA experiment team will refine the research plan in the future high heating power operation phase.

Broader Approach activities↗

Machine Learning Enabled Position Detection for 6.78 MHz UAV Wireless Power Transfer System

This paper presents a novel supervised machine learning (SML) approach for accurate position detection of the receiver coil in wireless power transfer (WPT) systems using only secondary-side electrical measurements, with applications in autonomous unmanned aerial vehicle (UAV) charging. The proposed method trains a supervised learning model to map measured secondary-side voltage and current features to the receiver’s spatial position with high precision. This enables an autonomous UAV to determine its location relative to the primary coil center, the optimal position for maximizing wireless charging efficiency. The sensing method is fully integrated into a standard WPT system, utilizing the same primary and secondary coils for both power transfer and position detection, thereby eliminating additional sensing hardware. The use of a 6.78 MHz operating frequency enhances positional sensitivity, as high-frequency near-field electromagnetic fields respond strongly to small spatial variations. Experimental validation is performed on a 30 W scaled prototype featuring a 210 mm × 140 mm primary coil, a 50 mm × 80 mm receiver coil, and a 15 mm air gap. Results demonstrate reliable position estimation and a strong correlation between predicted position and optimal coil alignment. This integrated framework unifying position detection and wireless charging offers a promising foundation for future autonomous electric vertical takeoff and landing (eVTOL) systems, enabling compact, hardware-efficient, and high-accuracy charging solutions.

Colak, Kerim [New York University]↗

Optimal Litz Wire Design for High-Power Wireless Charging System

In this study, an optimized Litz wire and polyphase coil winding design is proposed for high-power wireless charging systems operating at 85 kHz frequency. Litz wire in a wireless charging system contributes to more than half of the losses of the system, making it a critical design component. Here, the Litz wire is optimized through Finite Element Analysis (FEA) considering electrical and mechanical design aspects and the design was validated through experimental tests on different Litz wires with various strand-diameters, twisting ratio, and number of strands. The proposed optimal Litz wire maximizes the system efficiency considering the tradeoff between coil resistance and mutual inductance. The optimal Litz wire shows that Litz wire constructed with the 63µm strands significantly outperform the traditionally used Litz wire with 100µm strand diameter. Additionally, the coil with optimal Litz wire design shows 60% reduction in the copper volume for the same loss, and at the same time increase the coil-to-coil efficiency by more than 2% by increasing the mutual inductance and reducing coil current. The optimized Litz wire was implemented in a 22-kW wireless charging system achieving 94.7% efficiency.

Aydin, Emrullah [ORNL]↗

Magneto-Mechanical Optimization of Cross-Sections for $ \text{cos}(\theta)$Accelerator Magnets

The cross-section design of cos (θ) superconducting magnets is historically developed in a two-step process: initially, the coil geometry is defined on the basis of magnetic optimizations; then, the structure is designed around the coil. The first step searches for the best coil cross-section maximizing the magnetic field, margin, field quality and conductor efficiency. The latter step aims at limiting the coil stresses and deformations. However, the coil design, defined with the initial magnetic optimization, can influence the mechanical behaviour of the magnet, altering, for example, the peak stress during operation. As the critical current is a function of the applied strain, the mechanical implications of the coil cross-section design can limit the achievable performance. In this paper we propose an integrated optimization process that targets the peak stress on the conductor in addition to the magnetic objectives. Here the results are presented for a sample high-field Nb 3 Sn dipole: a 4-layer design aiming at ultimate conductor performance.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A 50 kA Superconducting Transformer for the Upcoming High-Field High-Current Testing Station at the BNL

Brookhaven national laboratory is upgrading its existing user facility to support R&D for High Energy Physics (HEP) and Fusion Energy Sciences (FES). The goal of this upgrade is to host the testing of the superconducting cables, conductors, joints and insert coils under high magnetic field (10 T), with currents up to 50 kA (present limit 20 kA) and at temperatures varying from 4 K to 40 K. To provide a current up to 50 kA to the sample, a superconducting core-less transformer is under construction. The superconducting transformer would additionally reduce the heat loss at the current leads at high currents. The SC transformer consists of two coaxial coils. The primary coil is inside the secondary coil. The primary coil consists of 3048 turns of rectangular wires (1.91 mm x 1.27 mm), wound in 24 layers. The secondary coil consists of 13 turns of the secondary cable (18.35 mm x 5.96 mm), wound in one layer. The parameters of the transformer are chosen to satisfy the space restrictions while using the available conductor. Here this paper presents the design of the 50-kA transformer.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Applied Metrology for the Assembly of the Nb 3 Sn MQXFA Quadrupole Magnets for the HL-LHC AUP

The US HL-LHC Accelerator Upgrade Project (AUP) is building Nb 3 Sn quadrupole magnets, called MQXFA, with plans to install 16 of them in the HL-LHC Interaction Regions. Variability in coil size must be dealt with at the assembly level, which requires timely and repeatable measurement of each coil. In this paper we will present the methodology used for coil measurements and the geometrical size data for the coils that have been measured thus far. We will also show the coil measurements of 8 coils before and after cold test. In conclusion, the Leica AT960-MR laser tracker with Spatial Analyzer software acquired to achieve these measurements has been used elsewhere in the project to great effect.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Conceptual Design of 20 T Hybrid Accelerator Dipole Magnets

Hybrid magnets are currently under consideration as an economically viable option towards 20 T dipole magnets for next generation of particle accelerators. In these magnets, High Temperature Superconducting (HTS) materials are used in the high field part of the coil with so-called insert coils, and Low Temperature Superconductors (LTS) like Nb 3 Sn and Nb-Ti superconductors are used in the lower field region with so-called outsert coils. The attractiveness of the hybrid option lays on the fact that, on the one hand, the 20 T field level is beyond the Nb 3 Sn practical limits of 15-16 T for accelerator magnets and can be achieved only via HTS materials; on the other hand, the high cost of HTS superconductors compared to LTS superconductors makes it advantageous exploring a hybrid approach, where the HTS portion of the coil is minimized. Here we present in this paper an overview of different design options aimed at generating 20 T field in a 50 mm clear aperture. The coil layouts investigated include the Cos-theta design (CT), with its variations to reduce the conductor peak stress, namely the Canted Cos-theta design (CCT) and the Stress Management Cos-theta design (SMCT), and, in addition, the Block-type design (BL) including a form of stress management and the Common-Coil design (CC). Results from a magnetic and mechanical analysis are discussed, with particular focus on the comparison between the different options regarding quantity of superconducting material, field quality, conductor peak stress, and quench protection.

43 PARTICLE ACCELERATORS↗

Quench Analysis of EIC Central Detector (ePIC) Solenoid Magnet (MARCO)

The 2.0 T superconducting solenoid magnet (MARCO) being designed to be built for the EIC central detector (ePIC). Here, the magnet consists of three set of coil in a vacuum impregnated coil pack. Each coil pack consists of a total 554 turns winding wrapped with 6 layers of winding per coil. The coil case assembly is cooled by supercritical helium at 4.6 K. This manuscript presents quench analysis carried out on the magnet system along with the conductor stability. For the normal operation the magnet at 4.6 K and at normal operating current, the quench evaluation is carried out at 4.7 K for design assessment. The quench analysis carried out using commercial multi-physics FEA tool along an equivalent single coil quench model and the requirements for the magnet protection is also presented.

Ghoshal, Probir K. [Thomas Jefferson National Acce↗

Observation of Electromagnetic Transients in a Nb3Sn 4-layer Dipole Mirror Magnet

During testing of the Stress Managed Cosine-Theta dipole mirror magnet SMCTM1, magnet quenches were observed following large voltage spikes in the half-coil voltage taps which preceded normal quench initiation. Following some recent work at CERN measuring power current converter transients in relation to flux jumps, an additional differential current probe was added to the magnet instrumentation. Measurements of this probe, as well as the half coil voltage taps show a fast and substantial current change preceding the quench, hinting at coil motion. A simple model based on relative shift of the inner and outer layer coils was developed which suggests the magnitude of coil shift events is on the estimated relative coil shift from the magnet constraint conditions. The behavior is shown to be reversible and characteristic of stick-slip.

Krave, Steven [Fermilab] (ORCID:0000000217521457)↗

A Low Loss, Fast Ramp HTS Solenoid Prototype for Compact Spherical Tokamaks

To explore AC loss characteristics of commercial Bi-2212 conductors made in the USA, a small ohmic heating (OH) prototype coil is being developed for compact tokamaks using high performance Bi-2212 wires newly manufactured by Bruker EST. Here, the goal is to build and test Bi-2212 prototype coils for fast ramp central solenoid (CS) operation of spherical tokamaks (ST). For a ST pilot plant, one of the key challenges is the tight space available for CS in a center column where in-board legs of the toroidal field (TF) and OH coils are assembled into a cryostat with a few millimeters clearance. A high current density Rutherford cable consisting of 17 legacy Bi-2212 wires, a contribution of the US Magnet Development Program (MDP), was fabricated at the Lawrence Berkeley National Laboratory (LBNL) for the development of fast ramp CS magnets in the ST Advanced Reactor (STAR) designed by PPPL. Characterization of the new and legacy HTS wires is presented, along with the coil design wound directly with new wire, and a Rutherford cable-wound solenoid using the legacy wire. A comparison of AC losses is made based on expected performance for a fast ramp ST operation. The HTS cable and cabled coil fabrication issues such as the heat treatment, coil mandrel design, assembly and 2212 quench characteristics are discussed, along with a test plan for CS design validation.

Zhai, Yuhu [Princeton Plasma Physics Laboratory (P↗

“Mirror” magnet experiment for quench studies, quench analysis techniques development and in support of superconducting magnet modeling

In order to progress on various research points related to superconducting magnets, we suggest performing series of tests with induced and natural quenches on a mirror magnet, probably using a “11 T” coil. The “mirror” is to have voltage taps instrumented on half the strands, on both coil ends. It is to be instrumented with multiple spot-heaters, of the order of ten, in designated pole-turn areas. Instrumentation is to include quench antenna array facing the inner coil surface, as well as acoustic sensors on the inner layer pole. Further, acoustic sensors at the magnet ends and an acoustic calibration transducer are to be installed. Thus, we are to test sensitivity and precision of acoustic and quench antenna (QA) array sensors, both at close proximity to the coil, and we are to test and commission acoustic on-magnet real-time “calibration”. New or extended DAQ will be tested as well. In addition to diagnostic development, the purpose of the magnet experiment is to investigate current redistribution in the coil, both during quenching and in operating conditions; to assess voltage build up across strands and in the coil segments during quenching, to explore voltage signature differentiation between different type of quenches; to improve modeling of processes during quenching and for magnet design purposes. In this experiment, we expect to be able to characterize the processes during a quench in unprecedented details.

43 PARTICLE ACCELERATORS↗

Development of NDE/NDT Tools for High-Volume & High-Speed Inspection of CFRP Structures in Automotive Manufacturing

Main advantages of the air-coupled ultrasound testing (ACUT) and electromagnetic testing (EMT) techniques for NDE of CFRP composites were non-contact sensing, scalability for high-speed inspection, cost-effectiveness, and non-hazardous operation. Despite these advantages, no systems that would satisfy the project requirements were commercially available. Hence, one of the major efforts of the Michigan State University (MSU) team at the initial stage of the project was to close this technological gap by developing, optimizing, and validating array sensors that would provide sufficient sensitivity, spatial coverage, and resolution for robust defect detection. Optimization of the ACUT and EMT sensor designs was performed using experimentally validated finite element models. Initial experiments using array probes were conducted on relatively flat CFRP samples. In parallel, the MSU team designed and assembled a portable platform with two robotic arms. The robots were equipped with newly designed sensors that enabled high-speed NDE of curved CFRP parts. Presently, the developed robotic platform can be used as a demo/template NDE system, which is easily adaptable to manufacturing environments and in-line NDE. The ACUT NDE system developed by the MSU team used a high-power 4-channel pulser receiver for parallel data acquisition. The array probes were designed by stacking commercially available ACUT transducers, which operated in the frequency range between 100 kHz and 500 kHz. MSU optimized the excitation procedure and developed wave focusing cones so as to reduce the crosstalk between the transducers and to provide higher pulse repletion frequency (PRF). The through-transmission (TT) and single-side access (SSA) inspection modes were successfully implemented. In the TT-ACUT, structural defects in CFRP were detected by passing ultrasonic waves through the test part. Hence, the ACUT transmitters and receivers needed to be placed on the opposite sides of the test part. In the SSA-ACUT, guided waves (GW) were excited in the test part using the transmitters and were sensed by the receivers from the same side. Multi-channel TT-ACUT and SSA-ACUT provided high-speed NDE, and were successfully validated on CFRP test samples with interlaminar delaminations and other embedded defects The EM techniques developed by the MSU team included: 1) eddy current testing (ECT), 2) capacitive imaging (CI) and hybrid dual-mode imaging. In ECT, structural damage was detected in CFRP using coils sensor arrays. In ECT, the excitation magnetic field is generated by passing an alternating current through a coil, which is placed above the test sample. The excitation field penetrates the conductive sample and induces the eddy currents in its transect. In turn, the eddy currents generate the reaction field, which affects the total field sensed by a coil. Hence, the presence of structural flaws will alter the eddy current flow and the picked-up signal. ECT is mostly sensitive to local changes of the electric conductivity of the test sample, and CFRPs are mostly conductive in the direction of carbon fibers. Hence, ECT was well suited for the detection of fiber damage/fiber irregularities. The MSU team developed printed circuit boards (PCB) with coil sensor arrays optimized for NDE of CFRP. Unlike most commercial probes designed for ECT of metallic structures, the MSU array probes were designed for operation in [1-10] MHz frequency range, which was optimal for low-conductive CFRP. Multiple sensing topologies (coil groups excitation/sensing arrangements) were implemented and successfully validated. Capacitive Imaging (CI) technique developed by MSU was complementary to ECT. In contrast to ECT, which was sensitive to local changes of the electrical conductivity, the CI was sensitive to local changes of the dielectric constant. Therefore, CI could provide information about matrix damage/matrix irregularities in CFRP. The MSU CI sensor arrays were made of multiple circular or rectangular open-plate capacitors printed on PCB. Sensors of this type are not commercially available. In addition to ECT and CI, the MSU team developed a hybrid (dual-mode) inductive/capacitive measurement technique that synergistically combined the benefits of inductive and capacitive sensing for rapid NDE of fiber reinforced polymer (FRP) composite structures. Fiber damage and fiber irregularities in FRPs were detected by configuring hybrid sensors as coil sensors. Similarly, matrix damage, matrix irregularities and interlaminar delaminations were detected by configuring hybrid sensors as capacitive sensors. ECT and CI were performed sequentially by means of electronic switching. Hence, eliminating the need for mounting two separate sensor arrays on the probe. Portable robotic platform was developed by MSU for multi-technique high-speed NDE of CFRP test parts. The platform had two 6-axis robots, which enabled inspection of curved parts in approximately a 6×6×6 ft 3 active scan area. On the software side, the MSU team integrated scripts for NDE hardware control with scripts for robot motion control. MSU also implemented automated path planning for the robots, reconstruction of part’s surfaces via stereovision, 3D rendering of inspection data, and image processing algorithms for enhanced defect detection. Automotive composite parts manufactured by Plasan Composites from Phase I were used to validate the ACUT and EMT techniques on representative testbeds. Among those parts were three X-braces for a Dodge Viper, one composite calibration plaque with known defects at known locations, and four other test sections, including sections from a front splitter, a corner section from a composite hood, and a high-pressure RTM panel made using non crimp fabric. Other test samples included CFRP and GFRP calibration plates with fiber/matrix defects fabricated at MSU/CVRC.

36 MATERIALS SCIENCE↗

Discrete modeling of a transformer with ALEGRA

We report progress on a task to model transformers in ALEGRA using the “Transient Magnetics” option. We specifically evaluate limits of the approach resolving individual coil wires. There are practical limits to the number of turns in a coil that can be numerically modeled, but calculated inductance can be scaled to the correct number of turns in a simple way. Our testing essentially confirmed this “turns scaling” hypothesis. We developed a conceptual transformer design, representative of practical designs of interest, and that focused our analysis. That design includes three coils wrapped around a rectangular ferromagnetic core. The secondary and tertiary coils have multiple layers. The tertiary has three layers of 13 turns each; the secondary has five layers of 44 turns; the primary has one layer of 20 turns. We validated the turns scaling of inductance for simple (one-layer) coils in air (no core) by comparison to available independent calculations for simple rectangular coils. These comparisons quantified the errors versus reduced number of turns modeled. For more than 3 turns, the errors are <5%. The magnetic field solver failed to converge (within 5000 iterations) for >10 turns. Including the core introduced some complications. It was necessary to capture the core surfaces in thin grid sheaths to minimize errors in computed magnetic energy. We do not yet have quantitative benchmarks with which to compare, but calculated results are qualitatively reasonable.

42 ENGINEERING↗

RHIC Run 22, 9 o'clock, a Snake in the Blue

The simulations detailed in this Tech. Note were aimed at determining new RHIC Blue 9 o’clock snake coil current and local closed orbit bump settings, together with updated - optimized - 3 o’clock snake settings, in order to recover from power supply dips which, early in the run (December 2021), caused the failure of 9 o’clock snake’s second coil in a first occurrence, and of its fourth coil in addition in a second occurrence, leaving the poor animal with just its coils 1 and 3. Documentation from a similar incident in Yellow in 2003 could be leaned on and allowed to promptly figure various necessary measures for swift recovery using the 9 o’clock Blue snake coils which survived the dip. Reference reports in particular that, in this 2003 incident, “[it was] decided to run the [failed] snake as a 88% partial snake while keeping the angles between the two snakes as 90° [...]. In general, the polarization level was not as good as Blue ring”. By contrast in this Run 22 incident, thorough simulations using the snake OPERA field maps helped determine new settings of the handicapped, 2-coil, Blue ring 9 o’clock snake currents and local closed orbit bump, and concurrently determine slight adjustment of the 3 o’clock snake currents, which allowed recovering full polarization at store, as good as could be expected from normal operation - even better over extended periods than in the Yellow ring.

43 PARTICLE ACCELERATORS↗