Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “central receiver”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

Arctic Black Carbon Aerosol Deposition Study North Slope of Alaska 2020- ACSM Measurements

Particles are removed from the atmosphere through both wet and dry deposition. These processes are poorly understood, though they constitute important uncertainties in climate and air quality models. This project aims to use observational constraints on particle fluxes to improve model representations of dry deposition. In support of black carbon (SP2) and particles (UHSAS) flux measurements at the meteorological tower, we measured non-refractory chemically-speciated aerosol composition with an Aerosol Chemical Speciation Monitor at the the NSA Central Facility (C1). ACSM measurements were made between 9 Sept and 26 Oct 2021. This site is a coastal tundra location, and received snow during the project.

Aerosol Chemical Speciation Monitor↗

Precise time dissemination and applications development on the Bonneville Power Administration system

The Bonneville Power Administration (BPA) uses IRIG-B transmitted over microwave as its primary system time dissemination. Problems with accuracy and reliability have led to ongoing research into better methods. BPA has also developed and deployed a unique fault locator which uses precise clocks synchronized by a pulse over microwaves. It automatically transmits the data to a central computer for analysis. A proposed system could combine fault location timing and time dissemination into a Global Position System (GPS) timing receiver and close the verification loop through a master station at the Dittmer Control Center. Such a system would have many advantages, including lower cost, higher reliability, and wider industry support. Test results indicate the GPS has sufficient accuracy and reliability for this and other current timing requirements including synchronous phase angle measurements. A phasor measurement system which provides phase angle has recently been tested with excellent results. Phase angle is a key parameter in power system control applications including dynamic braking, DC modulation, remedial action schemes, and system state estimation. Further research is required to determine the applications which can most effectively use real-time phase angle measurements and the best method to apply them.

K. E. Martin↗

Concept for a lunar array for very low frequency radio astronomy

We discuss the design considerations relevant to a very low frequency array, to be deployed on the lunar near side during an early expedition. Such an array would operate in the frequency range 1-10 MHz, and would consist nominally of 20 antennas distributed over a region approximately 40 km in extent. Each antenna station would consist of a crossed-dipole antenna, together with a receiver, digitizer, solar cells, and batteries. In addition, the station will contain a UHF transmitter for relaying the digitized signal to a central station where it will be transmitted to Earth for subsequent processing, including cross-correlation with signals from other antennas. Each antenna station (including the central station) would be deployed as a self-contained unit, mounted on a miniature robotic vehicle. No fixed structures are required for the array.

Marsh, Kenneth A.↗

Precise Time-Tag Generator For A Local-Area-Network Monitor

Time-tag-generating circuit designed for use in LAN monitor, monitors frames of data transmitted among computers on local-area network (LAN). To each frame of data that LAN monitor receives from LAN, time-tag generator appends ancillary data on time of arrival of frame, precise to within 1 microsecond of centrally generated time signal. Inserts ancillary time data in place of already used frame-check data before frames of data stored in memory of LAN monitor.

Stauffer, David R.↗

SU-E-T-522: A Multi-Isocenter VMAT Technique for Cranio-Spinal Irradiation

Purpose: Develop a matching VMAT field technique and investigate planning feasibility for treating the entire central nervous system (CNS) using Cranio-Spinal Irradiation (CSI) . Methods: Two patients diagnosed with acute myeloid leukemia (AML) presented with CNS involvement, received CSI, and were included in this study. The patients were treated with the traditional CSI technique: prone position, opposing lateral brain fields, two posterior fields (upper and lower spine), and 5mm junction shifts to improve dose uniformity. The patients were retrospectively re-planned using volumetric arc therapy (VMAT). The spine and brain were contoured to create the clinical target volume (CTV) as well as normal tissues including kidneys, lung and heart for optimization. Three isocenters were used for planning: brain, upper and lower spine. The beams were allowed to overlap by approximately 10cm. Entire 360 degree rotations were used for the brain fields and posterior 120 degree arcs were used for the spine fields. The dosimetric coverage of the target between the VMAT and traditional plans was compared, as well as the dose to normal tissues. Results: Both VMAT plans achieved improved dose uniformity in the CTV (standard deviation < 2%), and reduced hot spots (<110%). Dose to the heart was reduced, with the V10 being 12.7% and 28.2%, compared to 44.6% and 50.2%, respectively, for the traditional plan. Dose to the total lung V5 increased for the VMAT plans for both patients (21.6% and 27.8% compared to 12% and 13% respectively). The results for the kidneys were mixed with the mean dose increasing for one patient and decreasing for the other . Conclusion: The efficacy of planning CSI treatments using a matching VMAT technique was demonstrated. The developed technique has the potential to improve dose uniformity to the target while at the same time reduce the risk of under or over dosing the spine.

60 APPLIED LIFE SCIENCES↗

C-Band Scanning ARM Precipitation Radar (C-SAPR) Handbook

The C-band scanning ARM precipitation radar (C-SAPR) is a scanning polarimetric Doppler radar transmitting simultaneously in both H and V polarizations. With a 350-kW magnetron transmitter, this puts 125 kW of transmitted power for each polarization. The receiver for the C-SAPR is a National Center for Atmospheric Research (NCAR) -developed Hi-Q system operating in a coherent-on-receive mode. The ARM Climate Research Facility operates two C-SAPRs; one of them is deployed near the Southern Great Plains (SGP) Central Facility near the triangular array of X-SAPRs, and the second C-SAPR is deployed at ARM’s Tropical Western Pacific (TWP) site on Manus Island in Papua New Guinea.

47 OTHER INSTRUMENTATION↗

Performance Analysis of a Modular Small-Diamter Air Distribution System

This report investigates the feasibility of using a home-run manifold small-diameter duct system to provide space conditioning air to individual thermal zones in a low-load home. This compact layout allows duct systems to be brought easily within conditioned space via interior partition walls. Centrally locating the air handler unit in the house significantly reduces duct lengths. The plenum box is designed so that each connected duct receives an equal amount of airflow, regardless of the duct position on the box. Furthermore, within a reasonable set of length restrictions, each duct continues to receive similar airflow. The design method uses an additive approach to reach the total needed zonal airflow. Once the cubic feet per minute needed to satisfy the thermal load of a zone has been determined, the total number of duct runs to a zone can be calculated by dividing the required airflow by the standard airflow from each duct. The additive approach greatly simplifies the design effort and reduces the potential for duct design mistakes to be made. Measured results indicate that this plenum design can satisfy the heating load. However, the total airflow falls short of satisfying the cooling load in a hypothetical building. Static pressure inside the plenum box of 51.5 Pa limited the total airflow of the attached mini-split heat pump blower, thus limiting the total thermal capacity. Fan energy consumption is kept to 0.16 to 0.22 watt/CFM by using short duct runs and smooth duct material.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Performance Analysis of a Modular Small-Diameter Air Distribution System

This report investigates the feasibility of using a home-run manifold small-diameter duct system to provide space-conditioning air to individual thermal zones in a low-load home. This compact layout allows duct systems to easily be brought within conditioned space via interior partition walls. Centrally locating the air handling unit in the house significantly reduces duct lengths. The plenum box is designed so that each connected duct receives a similar amount of airflow—regardless of its position on the box. Furthermore, within a reasonable set of length restrictions each duct continues to receive similar airflow.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Three mirror glancing incidence system for X-ray telescope

A telescope suitable for soft X-ray astronomical observations consists of a paraboloid section for receiving rays at a grazing angle and a hyperboloid section which receives reflections from the paraboloid at a grazing angle and directs them to a predetermined point of focus. A second hyperboloid section is centrally located from the other two surfaces and positioned to reflect from its outer surface radiation which was not first reflected by the paraboloid. A shutter is included to assist in calibration.

Hoover, R. B.↗

Submicrosecond comparisons of time standards via the Navigation Technology Satellites (NTS)

An interim demonstration was performed of the time transfer capability of the NAVSTAR GPS system using a single NTS satellite. Measurements of time difference (pseudo-range) are made from the NTS tracking network and at the participating observatories. The NTS network measurements are used to compute the NTS orbit trajectory. The central NTS tracking station has a time link to the Naval Observatory UTC (USNO,MC1) master clock. Measurements are used with the NTS receiver at the remote observatory, the time transfer value UTC (USNO,MC1)-UTC (REMOTE, VIA NTS) is calculated. Intercomparisons were computed using predicted values of satellite clock offset and ephemeus.

Buisson, J. A.↗

Lightning detection and ranging

A lightning detector and ranging (LDAR) system developed at the Kennedy Space Center and recently transferred to Wallops Island is described. The system detects pulsed VHF signals due to electrical discharges occurring in a thunderstorm by means of 56-75 MHz receivers located at the hub and at the tips of 8 km radial lines. Incoming signals are transmitted by wideband links to a central computing facility which processes the times of arrival, using two independent calculations to determine position in order to guard against false data. The results are plotted on a CRT display, and an example of a thunderstorm lightning strike detection near Kennedy Space Center is outlined. The LDAR correctly identified potential ground strike zones and additionally provided a high correlation between updrafts and ground strikes.

Lennon, C. L.↗

Gamma radiation effects on the dynamic fatigue measurements of glass discs

Circular specimens of low iron soda lime silicate glass were blasted with grit after having a circular notch etched into their centers. After separation into two groups, one group was exposed to gamma radiation. The fracture strengths of all samples were then tested by the biaxial technique, i.e., specimens were balanced on three balls and loaded in the center by a piston. The irradiated samples had received a 140,000 Gy dose from a Co-60 source. An enhanced interaction between the ambient moisture and the grit-blasted central notch was observed in the irradiated samples, which displayed accelerated corrosion.

Ananaba, T. O. J.↗

Interferometric tracking system for the tracking and data relay satellite

This report documents construction and testing of the Interferometric Tracking System project developed under the NASA SBIR contract NAS5-30313. Manuals describing the software and hardware, respectively entitled: 'Field Station Guide to Operations' and 'Field Station Hardware Manual' are included as part of this final report. The objective of this contract was to design, build, and operate a system of three ground stations using Very Long Baseline Interferometry techniques to measure the TDRS orbit. The ground stations receive signals from normal satellite traffic, store these signals in co-located computers, and transmit the information via phone lines to a central processing site which correlates the signals to determine relative time delays. Measurements from another satellite besides TDRS are used to determine clock offsets. A series of such measurements will ultimately be employed to derive the orbital parameters, yielding positions accurate to within 50 meters or possibly better.

Effland, John E.↗

Building America Case Study: Mockup Small-Diameter Air Distribution System

This report investigates the feasibility of using a home-run manifold small-diameter duct system to provide space conditioning air to individual thermal zones in a low-load home. This compact layout allows duct systems to be brought easily within conditioned space via interior partition walls. Centrally locating the air hander unit in the house significantly reduces duct lengths. The plenum box is designed so that each connected duct receives an equal amount of airflow, regardless of the duct position on the box. Furthermore, within a reasonable set of length restrictions, each duct continues to receive similar airflow. The design method uses an additive approach to reach the total needed zonal airflow. Once the cubic feet per minute needed to satisfy the thermal load of a zone has been determined, the total number of duct runs to a zone can be calculated by dividing the required airflow by the standard airflow from each duct. The additive approach greatly simplifies the design effort and reduces the potential for duct design mistakes to be made. Measured results indicate that this plenum design can satisfy the heating load. However, the total airflow falls short of satisfying the cooling load in a hypothetical building. Static pressure inside the plenum box of 51.5 Pa limited the total airflow of the attached mini-split heat pump blower, thus limiting the total thermal capacity. Fan energy consumption is kept to 0.16 to 0.22 watt/CFM by using short duct runs and smooth duct material.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Mockup Small-Diameter Air Distribution System

This report investigates the feasibility of using a home-run manifold small-diameter duct system to provide space conditioning air to individual thermal zones in a low-load home. This compact layout allows duct systems to be brought easily within conditioned space via interior partition walls. Centrally locating the air hander unit in the house significantly reduces duct lengths. The plenum box is designed so that each connected duct receives an equal amount of airflow, regardless of the duct position on the box. Furthermore, within a reasonable set of length restrictions, each duct continues to receive similar airflow. The design method uses an additive approach to reach the total needed zonal airflow. Once the cubic feet per minute needed to satisfy the thermal load of a zone has been determined, the total number of duct runs to a zone can be calculated by dividing the required airflow by the standard airflow from each duct. The additive approach greatly simplifies the design effort and reduces the potential for duct design mistakes to be made. Measured results indicate that this plenum design can satisfy the heating load. However, the total airflow falls short of satisfying the cooling load in a hypothetical building. Static pressure inside the plenum box of 51.5 Pa limited the total airflow of the attached mini-split heat pump blower, thus limiting the total thermal capacity. Fan energy consumption is kept to 0.16 to 0.22 watt/CFM by using short duct runs and smooth duct material.

air distribution↗

Load planning in the dark: RH-TRU waste container load planning at Sandia National Laboratories/New Mexico - 15116

Sandia National Laboratories (Sandia) performed several sets of experiments during the 1970's and 1980's with fresh and irradiated mixed oxide (MOX) and uranium oxide (UO{sub 2}) materials designed to simulate various fuel responses under varying reactor conditions. These research materials were from light water and breeder mixed oxide reactors. The experimental vessels and extraneous piece parts resulting from the experiments were identified as eligible for disposal at the Waste Isolation Pilot Plant (WIPP) as remote-handled (RH) transuranic (TRU) waste. Once Sandia received the approval to dispose at WIPP, discussions began with the Carlsbad Field Office (CBFO) and Nuclear Waste Partnerships, LLC (NWP) to provide Central Characterization Program (CCP) support for certified acceptable knowledge, visual examination, and dose-to-curie for the repackaging effort. In addition to the WIPP support, Sandia was required to prepare a load plan describing the configuration of the parent containers and how they could be repackaged to meet WIPP and other regulatory requirements. However, all of these containers were packaged as material twenty (20) or thirty (30) years ago and the records of the packaging process and configuration were not documented as waste. Therefore, it seemed that the load plans were prepared with limited information regarding parent container configuration, hence in the dark. The design of the Auxiliary Hot Cell Facility (AHCF) in technical area (TA) V, where the repackaging was to take place, along with the shipping requirements for the RH 72-B cask, limited the options for repackaging. This configuration required that 0.114 m{sup 3} (30-gallon) containers be packaged in the hot cell, removed and placed into 0.208 m{sup 3} (55-gallon) containers to mitigate contamination issues. The material had been tracked as accountable nuclear material and Sandia had verified Material Control and Accountability (MC and A) data on each parent container. Based on the MC and A data, scaling factors could be determined and sampling and analysis was not required. However, it meant that parent containers could not be split into two daughter containers, though two or more parent containers could be combined into one daughter. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Tri-functional cannula for retinal endovascular surgery

A tri-functional cannula combines the functions of tissue Plasminogen Activator (tPA) solution delivery, illumination and venous pressure measurement. The cannula utilizes a tapered hollow-core optical fiber having an inlet for tPA solution, an attached fiber optic splitter configured to receive illumination light from an optical source such and a LED. A window in the cannula transmits the light to and from a central retinal vein. The return light is coupled to an optical detector to measure the pressure within the vein and determine whether an occlusion has been removed.

60 APPLIED LIFE SCIENCES↗

SiC Receiver/Reactor by Additive Manufacturing for Concentrated Solar Thermocatalysis with Thermal Energy Storage (Final Technical Report - Public)

The direct use of solar thermal energy provides opportunities for low-cost heating sources for a variety of applications. Ultra-high temperatures around 1000°C are high value and highly useful for energy-demanding industries. Many materials cannot withstand these conditions. In the area of Sustainable Chemicals, further limitations on material stability exist. Combining state-of-the-art materials with new designs provides a promising pathway for harvesting solar thermal energy and performing high temperature chemical processes. However, conventional manufacturing limits the potential for design flexibility. In this project, Additive Manufacturing was combined with advanced materials and new chemical reactor designs. In addition, 24/7 energy is necessary for chemical processing, and designs for ultra-high temperature thermal storage were devised. Specifically, preliminary design of a novel solar thermal receiver was developed in this project and designed to work with thermocatalytic reactors for producing sustainable chemicals and fuels. An ultra-high temperature particle storage system and heat exchangers were proposed to transport ultra-hot air as thermal fluid for the system. On a broader scale, this system could be used to tap solar thermal energy for a centralized facility with capability of transferring that heat to various segments at a full range of temperatures to 1000°C. The project pushed the temperature boundaries past those in current use, and Additive Manufacturing was envisaged for fabricating the receiver to meet requirements of extreme environments. An extensive analysis of silicon carbide additive manufacturing was performed to compare the thermal and mechanical properties of complex geometries compared to conventional material and those manufactured via other methods. The Additive Manufacturing via Binder-Jet printing was optimized and characterized to provide high quality and reproducible components capable of withstanding the proposed extreme environments. The designs for the concentrating solar thermal cavity with ultra-hot air thermal fluid showed high performance in simulations, attributable to the complex optimized geometries of the 3D printed systems. The bright future of Additive Manufacturing with advanced materials developments should provide more options and even higher quality as the technology further develops. Current costs for Additive Manufacturing of advanced ceramics is relatively low, however post-processing of the materials for extreme environments is currently high. There is little industrial-scale infrastructure for these, but it is growing as niche applications become more mainstream. The results of the project can be translated into similar extreme environments for concentrating solar thermal energy as well as its integration with ultra-hot air thermal fluids. A number of industries that require ultra-high temperatures need to electrify or otherwise decarbonize for climate goals, and this project showed that theoretically there is a pathway to do so with direct concentrated solar thermal power.

10 SYNTHETIC FUELS↗