Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “center”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

Industrial Assessment Center Program (Final Report)

This report summarizes the activities of the Industrial Assessment Center (IAC) at San Francisco State University (SFSU) under the Award No. DE-EE0007705 for the period of October 1, 2016 through September 30, 2021. The work performed under the award and related achievements are summarized per task in the statement of the work in the award.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Nuclear Criticality Safety Repository, Radiation Safety Information Computational Center (RSICC), & NDA Program [Slides]

This lecture covers the Nuclear Criticality Safety Repository (NCSR), Radiation Safety Information Computational center (RSICC), and Non-destructive Assay (NDA) program. The lecture provides information on the Fiscal year of 2022 and various phases of the NCSR Program and NDA. Further background information is provided for the RSICC and operations summary.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

Exploring the Limits of Cooling for Extreme Heat Flux Applications: Data Centers and Power Electronic

We developed an Extreme Heat Flux Micro-cooler (EHFµ-C) capable of removing heat flux of ~1 kW/cm 2 with a small temperature rise ~10°C. This represents greater than 10× reduction in thermal resistance compared to the state-of-the-art single-phase cooling technologies (~0.5 cm 2 -°C/W) that greatly increases the efficiency, resulting in improved performance and reliability for microprocessors and power electronics. The EHFµ-Cooler utilizes liquid wicking (no pump) and thin-film evaporation in a 30 µm thick wick porous microstructure such as copper inverse opal (CIO), silicon and AlN pin fins along with a 3D manifold (copper wiremesh and silicon) with liquid routing and vapor extraction channels achieving an unprecedented vapor quality ~ >0.9. The proposed EHFµ-Cooler significantly reduces device temperature, resulting in 25-50% improvement in reliability and device performance. Based on very conservative estimates, the total energy saving for data centers due to improved performance can be 6 billion kWh/year (>$300M). Better cooling, leading to more efficient, higher performance and more reliable power electronics, would save the nation 3 Quad of primary energy in 2030. Just for automotive application, a 10% increase in fuel efficiency for SiC-based power electronics equates to >20 million gallons of fuel savings annually. The proposed EHFµ-Cooler technology ensures the United States maintains its technological lead in high-performance computing and high-power electronics, while at the same time improving the energy efficiency, and as a result reducing energy-related emissions such as greenhouse gases.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

University of Dayton Industrial Assessment Center

The University of Dayton Industrial Assessment Center (UD-IAC) was established in 1981. Since then, the UD-IAC has completed 1,050 industrial energy assessments for the Department of Energy. The UD-IAC is committed to an ethic of continuous improvement, building upon the enormous knowledge and commitment it has developed over the past four decades and developing strong links to educational, research, and DOE initiatives. We feel lucky to be part of this great IAC program and pledge our best and most sustained efforts toward its continued success.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Influence of Polar Mutations on the Electronic and Structural Properties of Q A –· in Bacterial Reaction Centers

Reaction centers from Rb. sphaeroides with residue M265 mutated from isoleucine to threonine, serine, and asparagine (M265IT, M265IS, and M265IN, respectively) in the Q A –· state are studied by high-resolution ESEEM and ENDOR spectroscopies to investigate the structural characteristics of these mutants influencing the redox properties of the Q A site. All three mutants decrease the redox midpoint potential (E m ) of Q A by ~0.1 V, yet the mechanism for this drop in E m is unclear. In this work, we examine (i) the hydrogen bonding interactions between Q A –· and residues histidine M219 and alanine M260, (ii) the electron spin density distribution of the semiquinone, and (iii) the orientations of the ubiquinone methoxy substituents. 13 C measurements show no significant contribution of methoxy dihedral angles to the observed decrease in E m for the Q A mutants. Instead, 14 N three-pulse ESEEM data suggest electrostatic or hydrogen bond formation between the mutated M265 side chain and His-M219 N δ may be involved in the observed lowering of the Q A midpoint potential. For mutant M265IN, analysis of the proton hyperfine couplings reveals a weakened hydrogen bond network, resulting in an altered Q A –· spin density distribution. Here, the magnetic resonance study presented here is therefore most consistent with an electrostatic or structural perturbation of the His-M219 N δ hydrogen bond in these mutants as a mechanism for the ~0.1 V decrease in Q A E m .

14 SOLAR ENERGY↗

Support of the Massachusetts — NREL Wind Technology Testing Center (Cooperative Research and Development Final Report)

Under the shared-resources CRADA agreement, NREL will collaborate with the Massachusetts Technology Park Corporation, d/b/a Massachusetts Technology Collaborative (MTC), in its efforts to design, construct, and operate the Massachusetts-NREL Wind Technology Testing Center (WTTC), which is an advanced blade testing facility capable of testing blades up to at least 70 meters in length. The WTTC building will be owned and the facility operated by the MTC. In the CRADA, NREL agrees to provide certain capital equipment and certain NREL employees at the WTTC facility for training, commissioning, and continued technical assistance. In addition, NREL will provide one or more Laboratory staff to serve on any WTTC advisory committee, a no-cost license of the NREL blade-resonance fatigue testing technology (NREL Testing IP) and training to MA staff at the NREL blade test facilities in Colorado. MTC will provide all other resources necessary to design, construct, and operate the WTTC.

17 WIND ENERGY↗

NEXUS-DC: Nuclear Energy eXpedition for US Data Centers [Slides]

This presentation covers the growing interest in utilizing nuclear power to satisfy the increasing energy demands of data centers in the United States, emphasizing the factors that accelerate reactor deployment. It addresses clean and reliable energy needs, highlights the importance of power supply redundancy for reliability, and discusses challenges and solutions related to cooling, waste heat reuse, and techno-economics. Additionally, it includes a strength, weakness, opportunities and threat analysis and emphasizes community engagement and collaboration for accelerating regulatory approvals and reactor deployment.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Industrial Assessment Center for Underserved Delmarva Area

This report summarizes the work done by the Industrial and Training Assessment Center at the University of Delaware under the award number DE-EE0008796. The 38 audits performed during this period (DL0178 – DL0214) happened from October 2019 to October 2022. The facilities audited belong to a total of 27 industry types, according to the Standard Industry Classification (SIC).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Shedding Light on Primary Donors in Photosynthetic Reaction Centers

Chlorophylls (Chl)s exist in a variety of flavors and are ubiquitous in both the energy and electron transfer processes of photosynthesis. The functions they perform often occur on the ultrafast (fs–ns) time scale and until recently, these have been difficult to measure in real time. Further, the complexity of the binding pockets and the resulting protein-matrix effects that alter the respective electronic properties have rendered theoretical modeling of these states difficult. Recent advances in experimental methodology, computational modeling, and emergence of new reaction center (RC) structures have renewed interest in these processes and allowed researchers to elucidate previously ambiguous functions of Chls and related pheophytins. This is complemented by a wealth of experimental data obtained from decades of prior research. Studying the electronic properties of Chl molecules has advanced our understanding of both the nature of the primary charge separation and subsequent electron transfer processes of RCs. In this review, we examine the structures of primary electron donors in Type I and Type II RCs in relation to the vast body of spectroscopic research that has been performed on them to date. Further, we present density functional theory calculations on each oxidized primary donor to study both their electronic properties and our ability to model experimental spectroscopic data. This allows us to directly compare the electronic properties of hetero- and homodimeric RCs.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Automated Lane Centering: An Off-the-Shelf Computer Vision Product vs. Infrastructure-Based Chip-Enabled Raised Pavement Markers

Safe autonomous vehicle (AV) operations depend on an accurate perception of the driving environment, which necessitates the use of a variety of sensors. Computational algorithms must then process all of this sensor data, which typically results in a high on-vehicle computational load. For example, existing lane markings are designed for human drivers, can fade over time, and can be contradictory in construction zones, which require specialized sensing and computational processing in an AV. But, this standard process can be avoided if the lane information is simply transmitted directly to the AV. High definition maps and road side units (RSUs) can be used for direct data transmission to the AV, but can be prohibitively expensive to establish and maintain. Additionally, to ensure robust and safe AV operations, more redundancy is beneficial. A cost-effective and passive solution is essential to address this need effectively. In this research, we propose a new infrastructure information source (IIS), chip-enabled raised pavement markers (CERPMs), which provide environmental data to the AV while also decreasing the AV compute load and the associated increase in vehicle energy use. CERPMs are installed in place of traditional ubiquitous raised pavement markers along road lane lines to transmit geospatial information along with the speed limit using long range wide area network (LoRaWAN) protocol directly to nearby vehicles. This information is then compared to the Mobileye commercial off-the-shelf traditional system that uses computer vision processing of lane markings. Our perception subsystem processes the raw data from both CEPRMs and Mobileye to generate a viable path required for a lane centering (LC) application. To evaluate the detection performance of both systems, we consider three test routes with varying conditions. Our results show that the Mobileye system failed to detect lane markings when the road curvature exceeded ±0.016 m -1 . For the steep curvature test scenario, it could only detect lane markings on both sides of the road for just 6.7% of the given test route. On the other hand, the CERPMs transmit the programmed geospatial information to the perception subsystem on the vehicle to generate a reference trajectory required for vehicle control. The CERPMs successfully generated the reference trajectory for vehicle control in all test scenarios. Moreover, the CERPMs can be detected up to 340 m from the vehicle’s position. Our overall conclusion is that CERPM technology is viable and that it has the potential to address the operational robustness and energy efficiency concerns plaguing the current generation of AVs.

33 ADVANCED PROPULSION SYSTEMS↗

Implications of AI and Data Center Service Demand on Energy, Water, and Economic Systems

This talk focuses on the challenges posed by the rapid growth of data centers (DCs), which rely heavily on electricity, water, land, and mineral resources, and have significant interactions with economic growth. The U.S. leads in DC deployment, but understanding how resource demands and constraints impact DC expansion requires strategic multisector analysis. To address this, the talk introduces a new conceptual framework and modeling capability within GCAM-USA, allowing integrated analysis of DC service demand, electricity, and direct and indirect water needs under varied scenarios. Insights include state-level water and electricity trends for DCs, uncertainty bounds, and the broader implications for resources and economics.

Data Centers↗

Alternative Fuels Data Center

This presentation provides an overview of the Alternative Fuels Data Center for the 2026 Transportation Technologies Annual Merit Review, including project objectives, milestone, approach to developing and maintaining the website, project accomplishments and progress, and collaboration with other national labs and external partners.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Project Phase 1 Report: Reducing Data Center Peak Cooling Demand and Energy Costs With Cold Underground Thermal Energy Storage (Cold UTES)

Cold Underground Thermal Energy Storage (Cold UTES) is an ultra-long duration grid energy storage technology. With Cold-UTES, low-cost grid power is converted to cold thermal energy and stored in the native subsurface rock at the point of use. Cold UTES is one approach within the general category of engineered geothermal systems. Cold UTES for peak-hour cooling of data centers (DCs) was studied for deployment in Maricopa County, Arizona and Loudoun County, Virgina using thermal storage capacities from 4 GWh-th to over 1,000 GWh-th (>1 Terawatt-hour). The two sites have different power and transmission systems, available grid energy resources, daily and seasonal load profiles, weather conditions, and grid regulatory requirements. The study results indicate high value for both locations and because of this, likely indicates value across most of the US and the world. The basis of the study was a 1,000 MW-e hourly electric use of DC computing and auxiliary loads, which was modeled as 1 GW-th of thermal load to a dry cooled heat rejection system - i.e. a cooling system that does not consume water. The electric power required for cooling the DC varies as the air temperature changes. In cold weather only the dry-coolers are used, with an electrical load for cooling load as low as 10 MW-e. In hot summer hours, chillers and dry- coolers are required, which raises the electrical load for cooling load to as much as 300 MW-e. The continuous and peak cooling electrical loads result in a grid interconnection requirement of no less than 1,300 MW-e. From both a grid and thermal design modeling perspective the 1.3 GW-e could either be a single facility or result from the total load at multiple sites.

15 GEOTHERMAL ENERGY↗