Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “cavities”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

Strong parametric dispersive shifts in a statically decoupled two-qubit cavity QED system

Qubits in cavity quantum electrodynamic (QED) architectures are often operated in the dispersive regime, in which the operating frequency of the cavity depends on the energy state of the qubit, and vice versa. The ability to tune these dispersive shifts provides additional options for performing either quantum measurements or logical manipulations. Here we couple two transmon qubits to a lumped-element cavity through a shared superconducting quantum interference device (SQUID). In this work, our design balances the mutual capacitive and inductive circuit components so that both qubits are statically decoupled from the cavity with low flux sensitivity, offering protection from decoherence processes. Parametric driving of the SQUID flux enables independent, dynamical tuning of each qubit’s interaction with the cavity. As a practical demonstration, we perform pulsed parametric dispersive readout of both qubits. The dispersive frequency shifts of the cavity mode follow the theoretically expected magnitude and sign. This parametric approach creates an extensible, tunable cavity QED framework with various future applications, such as entanglement and error correction via multi-qubit parity readout, state and entanglement stabilization, and parametric logical gates.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Cavity morphology in a Ni based superalloy under heavy ion irradiation with hot pre-injected helium. II

In the current investigation, TEM in-situ heavy ion (1 MeV Kr{sup 2+}) irradiation with helium pre-injected at elevated temperature (400 °C) was conducted to simulate in-reactor neutron irradiation induced damage in CANDU spacer material Inconel X-750, in an effort to understand the effects of helium on irradiation induced cavity microstructures. Three different quantities of helium, 400 appm, 1000 appm, and 5000 appm, were pre-injected directly into TEM foils at 400 °C. The samples containing helium were then irradiated in-situ with 1 MeV Kr{sup 2+} at 400 °C to a final dose of 5.4 dpa (displacement per atom). Cavities were formed from the helium injection solely and the cavity density and size increased with increasing helium dosage. In contrast to previous heavy ion irradiations with cold pre-injected helium, heterogeneous nucleation of cavities was observed. During the ensuing heavy ion irradiation, dynamical observation showed noticeable size increase in cavities which nucleated close to the grain boundaries. A “bubble-void” transformation was observed after Kr{sup 2+} irradiation to high dose (5.4 dpa) in samples containing 1000 appm and 5000 appm helium. Cavity distribution was found to be consistent with in-reactor neutron irradiation induced cavity microstructures. This implies that the distribution of helium is greatly dependent on the injection temperature, and helium pre-injection at high temperature is preferred for simulating the migration of the transmutation produced helium.

36 MATERIALS SCIENCE↗

THE STRUCTURE OF PRE-TRANSITIONAL PROTOPLANETARY DISKS. I. RADIATIVE TRANSFER MODELING OF THE DISK+CAVITY IN THE PDS 70 SYSTEM

Through detailed radiative transfer modeling, we present a disk+cavity model to simultaneously explain both the spectral energy distribution (SED) and Subaru H-band polarized light imaging for the pre-transitional protoplanetary disk PDS 70. In particular, we are able to match not only the radial dependence but also the absolute scale of the surface brightness of the scattered light. Our disk model has a cavity 65 AU in radius, which is heavily depleted of sub-micron-sized dust grains, and a small residual inner disk that produces a weak but still optically thick near-IR excess in the SED. To explain the contrast of the cavity's edge in the Subaru image, a factor of {approx}1000 depletion for the sub-micron-sized dust inside the cavity is required. The total dust mass of the disk may be on the order of 10{sup -4} M {sub Sun }, only weakly constrained due to the lack of long-wavelength observations and the uncertainties in the dust model. The scale height of the sub-micron-sized dust is {approx}6 AU at the cavity edge, and the cavity wall is optically thick in the vertical direction at H-band. PDS 70 is not a member of the class of (pre-)transitional disks identified by Dong et al., whose members only show evidence of the cavity in the millimeter-size dust but not the sub-micron-sized dust in resolved images. The two classes of (pre-)transitional disks may form through different mechanisms, or they may simply be at different evolution stages in the disk-clearing process.

79 ASTRONOMY AND ASTROPHYSICS↗

Advances in Nb 3 Sn superconducting radiofrequency cavities towards first practical accelerator applications

Abstract Nb 3 Sn is a promising next-generation material for superconducting radiofrequency cavities, with significant potential for both large scale and compact accelerator applications. However, so far, Nb 3 Sn cavities have been limited to continuous wave accelerating fields <18 MV m −1 . In this paper, new results are presented with significantly higher fields, as high as 24 MV m −1 in single cell cavities. Results are also presented from the first ever Nb 3 Sn-coated 1.3 GHz 9-cell cavity, a full-scale demonstration on the cavity type used in production for the European XFEL and LCLS-II. Results are presented together with heat dissipation curves to emphasize the potential for industrial accelerator applications using cryocooler-based cooling systems. The cavities studied have an atypical shiny visual appearance, and microscopy studies of witness samples reveal significantly reduced surface roughness and smaller film thickness compared to typical Nb 3 Sn films for superconducting cavities. Possible mechanisms for increased maximum field are discussed as well as implications for physics of RF superconductivity in the low coherence length regime. Outlook for continued development is presented.

43 PARTICLE ACCELERATORS↗

Enhanced tunable cavity development for axion dark matter searches using a piezoelectric motor in combination with gears

Most search experiments sensitive to quantum chromodynamics (QCD) axion dark matter benefit from microwave cavities, as electromagnetic resonators, that enhance the detectable axion signal power and thus the experimental sensitivity drastically. As the possible axion mass spans multiple orders of magnitude, microwave cavities must be tunable and it is desirable for the cavity to have a tunable frequency range that is as wide as possible. Since the tunable frequency range generally increases as the dimension of the conductor tuning rod increases for a given cylindrical conductor cavity system, we developed a cavity system with a large dimensional tuning rod in order to increase this. Here we, for the first time, employed not only a piezoelectric motor, but also gears to drive a large and accordingly heavy tuning rod, where such a combination to increase driving power can be adopted for extreme environments as is the case for axion dark matter experiments: cryogenic, high-magnetic-field, and high vacuum. Thanks to such higher power derived from the piezoelectric motor and gear combination, we realized a wideband tunable cavity whose frequency range is about 42% of the central resonant frequency of the cavity, without sacrificing the experimental sensitivity too much.

47 OTHER INSTRUMENTATION↗

Development of a cryocooler conduction-cooled 650 MHz SRF cavity operating at ~10 MV/m cw accelerating gradient

SRF cavities for particle acceleration are conventionally operated immersed in a bath of liquid helium at 4.2 K and below. Although this cooling configuration is practically and economically viable for large scientific accelerator installations, it may not be so for smaller accelerators intended for industrial applications such as the treatment of wastewater, sludge, flue gases, etc. In this paper, we describe a procedure to operate SRF cavities without liquid helium that can be used to construct electron-beam sources for industrial applications of electron irradiation (1-10 MeV electron energy). In this procedure, an elliptical single-cell 650 MHz niobium-tin coated niobium cavity is coupled to a closed-cycle 4.2 K cryocooler using high purity aluminum thermal links. The cryocooler conductively extracts heat (RF dissipation) from the cavity without requiring liquid helium around the cavity. We present construction details of this cryocooler conduction-cooling technique and systematic experiments that have demonstrated ~10 MV/m cw gradient on the cavity. By straightforward scaling up the cavity length and number of cryocoolers, the technique will provide the complete range of 1-10 MeV electron energy for industrial applications.

43 PARTICLE ACCELERATORS↗

Optically accessible high-finesse millimeter-wave resonator for cavity quantum electrodynamics with atom arrays

Cavity quantum electrodynamics (QED) is a powerful tool in quantum science, enabling preparation of nonclassical states of light and scalable entanglement of many atoms coupled to a single field mode. While the most coherent atom-photon interactions have been achieved using superconducting millimeter-wave cavities coupled to Rydberg atoms, these platforms so far lack the optical access required for trapping and addressing individual atomic qubits. We present a millimeter-wave Fabry-Pérot cavity with finesse 5.8⁢(1) ×10 7 at a temperature of 1 K providing generous transverse optical access (numerical aperture 0.56). Conflicting goals of strong atom-photon coupling and optical access motivate a near-confocal geometry. Close to confocality, however, postparaxial corrections to the cavity spectrum introduce unexpected degeneracies between transverse modes, leading to excess cavity loss. Modeling these corrections allows for tuning the cavity geometry to evade this loss, producing a high finesse that will enable cavity QED experiments with trapped atoms deep in the strong coupling regime.

Zhang, Tony [Stanford Univ., CA (United States); S↗

Fast Sideband Control of a Multimode Cavity Memory with Weak Dispersive Coupling to a Transmon

Mitigating ancilla-mediated error channels is a critical challenge in controlling high-quality superconducting cavities using circuit quantum electrodynamics (cQED). We address this by weakening the dispersive coupling while demonstrating fast, high-fidelity multimode control through transmon-mediated sideband interactions. We implement transmon-cavity SWAP gates with speeds up to 30 times larger than the bare dispersive coupling. Combined with transmon rotations, this enables universal state preparation in a single mode, though achieving unitary gates and extending control to multiple modes remains a challenge. In this work, we overcome this limitation by introducing two control strategies: (i) a shelving technique that stores populations in sideband-transparent states, and (ii) a method that exploits the dispersive shift to implement photon-number-selective transmon-cavity SWAP gates. We use these protocols to prepare Fock and binomial code states across any of the ten modes of a multimode cavity with millisecond coherence times—serving as a multimode quantum memory. We demonstrate unitaries that encode and decode an arbitrary qubit state from the transmon into corresponding vacuum and Fock state superpositions, as well as entangled NOON states of cavity mode pairs—a scheme extendable to arbitrary multimode Fock encodings in the cavity modes. Furthermore, we implement a new binomial encoding gate that converts arbitrary transmon superpositions into binomial code states in any cavity mode at a rate exceeding the dispersive shifts in our system, achieving an average post-selected state fidelity of 96.3% in a 4 μ⁢s gate time. By using precalibrated transmon and sideband pulses, our work demonstrates multimode control with significantly reduced calibration overhead, enabling efficient unitary operations using sideband interactions in multimode cQED systems.

Huang, Jordan [Rutgers Univ., Piscataway, NJ (Unit↗

Hybrid Physical Chemical Vapor Deposition of Magnesium Diboride Inside 3.9 GHz Mock Cavities

Magnesium diboride (MgB 2 ) is considered a candidate for the next generation superconducting radio frequency (SRF) cavities due to its higher critical temperature T c (40 K) and increased superheating field (H sh ) compared to other conventional superconductors. These properties can lead to reduced BCS surface resistance (R BCS S ) and residual resistance (R res ), according to theoretical studies, and enhanced accelerating field (E acc ) values. Here, we investigated the possibility of coating the inner surface of a 3.9 GHz SRF cavity with MgB 2 by using a hybrid physical-vapor deposition (HPCVD) system designed for this purpose. To simulate the actual 3.9 GHz SRF cavity, we also employed a stainless steel mock cavity for the study. The film qualities were characterized on small substrates that were placed at the selected positions within the cavity. MgB 2 films on stainless steel foils, niobium pieces, and SiC substrates showed transition temperatures in the range of 30-38 K with a c-axis-oriented crystallinity observed for films grown on SiC substrates. Dielectric resonator measurements at 18 GHz resulted in a quality factor of over 30 000 for the MgB 2 film grown on a SiC substrate. Furthermore, by employing the HPCVD technique, a uniform film was achieved across the cavity interior, demonstrating the feasibility of HPCVD for MgB 2 coatings for SRF cavities.

36 MATERIALS SCIENCE↗

Operation and investigation of a tilted bottom cavity for pyrgeometer characterizations

A new cavity for pyrgeometer characterizations has been built at the Infrared Radiometry Section of the World Radiation Center (WRC-IRS) at PMOD/WRC. The calculated effective emissivity of 0.99993{+-}0.00033 was obtained from Monte Carlo simulations taking into account the geometry and the measured temperature distributions of the cavity. The cavity is operated in a temperature range of -30 deg. C to +30 deg. C and is initially flushed with nitrogen to reduce the relative humidity in the cavity. The estimated uncertainties of retrieved pyrgeometer parameters k1, k2, and k3 are {+-}0.024, {+-}0.0008, and {+-}0.03, respectively. The relative uncertainty of pyrgeometer sensitivity C is 0.8%. The comparison with the cavity used since 1995 at PMOD/WRC gave average differences of 0.005, 0.00026, and 0.08 for k1, k2, and k3, respectively. The pyrgeometer sensitivity retrieved with the new cavity is on average 1.0% higher than with the original cavity.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Frequency dependence of BCS and residual resistance using multi-mode measurement of nitrogen-doped single-cell elliptical cavities

Various cavity surface treatments have been found to significantly improve cavity quality factor, Q0, with one such treatment being nitrogen-doping (N-doping). N-doped 1.3 GHz cavities were the first found to exhibit anti-Q slope, the increase of Q0 with accelerating field, Eacc. However, even with the use of the same N-doping recipes, this anti-Q slope behavior has not been realized in sub-GHz frequency cavities. In this study, we measured the Q0 and surface resistance, RS, of our N-doped, single-cell, elliptical cavity for both the 644 MHz fundamental mode (FM) and 1.45 GHz higher-order mode (HOM). As a result of multi-mode measurements, the BCS and residual resistances, the temperature-dependent and temperature-in-dependent RF surface resistances, could be determined without the influence of cavity-to-cavity surface treatment variations. We will discuss the frequency-dependent behaviors of the BCS and residual resistances.

Accelerator Physics↗

Rework Recipe Development, Analysis and Results of Select 9-Cell Cavities for LCLS-II

The SLAC National Accelerator Laboratory is currently constructing a major upgrade to its accelerator, the Linac Coherent Light Source II (LCLS-II). Several Department of Energy laboratories, including the Thomas Jefferson National Accelerator Facility (JLab) and Fermi National Accelerator Laboratory (FNAL), are collaborating in this project. The cryomodules for this project each consist of eight 1.3-GHz cavities produced by two vendors, Research Instruments GmbH in Germany (RI*) and Ettore Zanon S.p.a. in Italy (EZ*), using niobium cell material from Tokyo Denkai Co., Ltd. (TD) and Ningxia Orient Tantalum Industry Co., Ltd. (OTIC/NX)). During the initial production run, cavity performance from one of the vendors (Vendor A) was far below expectation. All the cavities had low Q0, later attributed to minimal EP as well as high-flux-trapping NX material, early quench behaviour below 18 MV/m, with many having Q0 roll-off at 12-16 MV/m. Production was stopped multiple times over the following 6 months, with test batches of cavities being made to ascertain the root cause of the problem. The final root cause of the problem was found to be inappropriate grinding of the RF surface prior to welding which left normal conducting inclusions in the surface. In addition, most cavities showed internal and external weld spatter which required post weld grinding and a very rough surface from operating the electropolishing machine in an etching rather than polishing regime. All issues have been corrected on new cavities and rework is underway on the originally effected cavities.

Macha, Kurt M.↗

802 MHz ERL Cavity Design and Development

In the framework of a collaboration between CERN and JLab, an SRF accelerating cavity for energy recovery linacs operating at 802 MHz was developed in the context of the CERN's Large Hadron electron Collider (LHeC) design study. A single-cell and a five-cell cavity from fine grain high RRR niobium were built at JLab to validate the basic RF design in vertical tests. Two copper single-cell cavities were produced in parallel for R&D purposes at CERN. The cavity design has since been adapted as baseline for the main linac cavities in the proposed Powerful Energy Recovery Linac Experiment facility (PERLE) at Orsay. Details concerning the cavity fabrication and test results for the Nb cavities are presented.

Marhauser, Frank↗

SRF Cavity Fault Classification Using Machine Learning At CEBAF

The Continuous Electron Beam Accelerator Facility (CEBAF) at Jefferson Lab is the first large high power CW recirculating electron accelerator to make use of SRF accelerating structures. The structures are configured in two anti-parallel linacs connected by arcs. Each linac consists of twenty C20/C50 cryomodules each containing eight 5-cell cavities and five C100 upgrade cryomodules each containing eight 7-cell cavities. Accurately classifying the source of cavity faults is critical for improving accelerator performance. A cavity fault triggers a waveform acquisition process where 17 waveform records sampled at 5 kHz are recorded for each of the 8 cavities in the affected cryomodule. The waveform record length is sufficiently long for transient microphonic effects to be observable. This data combined with archived signals sampled at 10 Hz are used to classify faults. Significant time is required for a subject matter expert to analyze and identify the intra-cavity signatures of imminent faults. This paper describes a path forward that utilizes machine learning for automatic fault classification. Post-training identification of the physical origins of faults are discussed, as are potential machine-trained model-free implementations of trip avoidance procedures. These methods should provide new insights into cavity fault mechanisms and facilitate intelligent optimization of cryomodule performance

Solopova, A.↗

RECENT RESULTS FROM Nb3Sn COATED SINGLE-CELL CAVITIES COMBINED WITH SAMPLE STUDIES AT JEFFERSON LAB

The critical temperature (~ 18 K) and superheating field (~ 425 mT) of Nb3Sn are almost twice that of niobium, thereby promising the higher quality factor and accelerating gradient at any given temperature compared to traditional SRF cavities made of niobium. It can enable higher temperature for cavity operation (4 K Vs. 2 K), resulting in significant reduction in both capital and operating cost for the cryoplant. Several single-cell cavities along with witness samples were coated with Nb3Sn to explore, understand and improve the coating process for betterment of cavity performance. RF measurements of coated cavities combined with material characterization of witness samples were employed to update the coating process. Following some modifications to the existing coating process, we were able to produce Nb3Sn cavity with quality factor ? 2.1010 for accelerating gradient up to 15 MV/m at 4 K, without any significant Q-slope. In this article, we will discuss recent results from several Nb3Sn coated single-cell cavities combined with material studies of witness samples.

Eremeev, G. V.↗

Development of Nb3Sn multicell cavity coatings

Nb3Sn films have the potential to replace niobium in SRF cavities. Besides single-cell cavity efforts to improve Nb3Sn films, we are working to replicate single-cell results onto the practical 5-cell CEBAF cavities. High quality factors (10E11 @ 2.0K and 10E10 @ 4.3 K) have been measured, but the cavities are typically limited by strong low-field Q-slopes and quenches. Two of the cavities were selected to be assembled into a "mock-up" cavity string unit, the standard step before installation into a cryomodule. Comparison of test results between VTA and pair test offered the first glimpse into post-processing effects on the cavity performance.

Eremeev, G.↗

Superconducting Radio-frequency Cavity Fault Classification Using Machine Learning at Jefferson Laboratory

We report on the development of machine learning models for classifying C100 superconducting radiofrequency (SRF) cavity faults in the Continuous Electron Beam Accelerator Facility (CEBAF) at Jefferson Lab. Of the 418 SRF cavities in CEBAF, 96 are designed with a digital low-level RF system configured such that a cavity fault triggers recordings of RF signals for each of eight cavities in the cryomodule. Subject matter experts analyze the collected time-series data and identify which of the eight cavities faulted first and classify the type of fault. This information is used to find trends and strategically deploy mitigations to problematic cryomodules. However, manually labeling the data is laborious and time-consuming. By leveraging machine learning, near real-time - rather than postmortem - identification of the offending cavity and classification of the fault type has been implemented. We discuss the performance of the machine learning models during a recent physics run. We also discuss efforts for further insights into fault types through unsupervised learning techniques and present preliminary work on cavity and fault prediction using data collected prior to a failure event.

Tennant, C. D.↗

Observation of Polarization-Dependent Changes in Higher-Order Mode Responses as a Function of Transverse Beam Position in Tesla-Type Cavities at FAST

Higher-order modes (HOMs) in superconducting rf cavities present problems for an electron bunch traversing the cavity in the form of long-range wakefields from previous bunches. These may dilute the emittance of the macropulse average, especially with low emittance beams at facilities such as the European X-ray Free-electron Laser (XFEL) and the upgraded Linac Coherent Light Source (LCLS-II). Here we present observations of HOMs driven by the beam at the Fermilab Accelerator Science and Technology (FAST) facility. The FAST facility features two independent TESLA-type cavities (CC1 and CC2) after a photocathode rf gun followed by an 8-cavity cryomodule. The HOM signals were acquired from cavities using bandpass filters of 1.75 ± 0.15 GHz, 2.5 ± 0.2 GHz, and 3.25 ± 0.2 GHz and recorded using an 8-GHz, 20 GSa/s oscilloscope. The frequency resolution obtained is sufficient to separate polarization components of many of the HOMs. These HOM signals were captured from CC1 and cavities 1 and 8 of the cryomodule for various initial trajectories through the cavities, and we observe correlations between trajectory, HOM signals, and which polarization component of a mode is affected.

Thurman-Keup, Randy Michael↗