Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “capacity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

EV Hosting Capacity Analysis on Distribution Grids

The increasing trend in electric vehicle (EV) adoption can cause challenges to traditional electric grid operations if utilities are not equipped with tools and methods to effectively manage these fleets. Growing EV charging loads will alter the magnitude and duration of conventional peaks in demand profiles and even significantly shift them, potentially causing operational violations in the distribution grid. This paper presents the development and results of an EV hosting capacity tool to quantify the impacts of injecting large numbers of EV charging loads and to determine the available capacity of existing distribution feeders to continue providing reliable and affordable grid operations. Tools like the hosting capacity analysis would enable utilities to better prepare for grid operations in the near future while exploring the impact and effectiveness of strategies to manage these loads, such as peak pricing and smart charging. This paper evaluates the hosting capacity of some real-world feeders to accommodate EV charging loads, including extreme fast-charging options.

distribution grid↗

PV Hosting Capacity Estimation: Experiences with Scalable Framework

Hosting capacity is an indication of the amount of solar photovoltaics (PV) that can be hosted in a distribution system without additional changes to infrastructure or oper-ations. This paper presents a framework for estimating the PV hosting capacity at scale. First, we analyze computational, modeling and other key challenges of performing relevant, large-scale simulations, provided along with the experiences and lessons learned. Then, we develop two open-source Python-based software tools to conduct repeatable distribution analyses: the Distribution Integration Solution Cost Options (DISCO) for configuring and analyzing simulations and the Job Automation and Deployment Engine (JADE) for parallelizing jobs on high-performance computing clusters. A case study of hosting capacity estimation for the SMART-DS San Francisco (SFO) 2000+ synthetic feeders, is used to demonstrate the capability of the developed DISCO+JADE framework and tools. The framework and tools can help utilities assess the overall hosting capacity of their service territory, which can help them better plan for the overall upgrade costs to integrate more PV in the future. The experiences are shared to aid the tool users and researchers to conduct relevant studies and research.

distributed energy resources↗

Locational Sensitivity Investigation on PV Hosting Capacity and Fast Track PV Screening

A 15% PV penetration threshold is commonly used by utilities to define photovoltaic (PV) screening methods where PV penetration is defined as the ratio of total solar PV capacity on a line section to peak load. However, this method doesn't take into account PV locational impact or feeder characteristics that could strongly change the feeder's capability to host PVs. This paper investigates the impact of PV location and phase connection type on PV hosting capacity, and then proposes a fast-track PV screening approach that leverages various PV hosting capacity metric responding to different PV locations and types. The proposed study could help utilities to evaluate PV interconnection requests and also help increase the PV hosting capacity of distribution feeders without adverse impacts on system voltages.

14 SOLAR ENERGY↗

On Distributed PV Hosting Capacity Estimation, Sensitivity Study, and Improvement

This paper first studies the estimated distributed PV hosting capacities of seventeen utility distribution feeders using the Monte Carlo simulation based stochastic analysis, and then analyzes the sensitivity of PV hosting capacity to both feeder and photovoltaic system characteristics. Furthermore, an active distribution network management approach is proposed to maximize PV hosting capacity by optimally switching capacitors, adjusting voltage regulator taps, managing controllable branch switches and controlling smart PV inverters. The approach is formulated as a mixed-integer nonlinear optimization problem and a genetic algorithm is developed to obtain the solution. Multiple simulation cases are studied and the effectiveness of the proposed approach on increasing PV hosting capacity is demonstrated.

14 SOLAR ENERGY↗

Cut–and–chip harvester material capacity and fuel performance on commercial-scale willow fields for varying ground and crop conditions

Shrub willow (Salix spp.) is capable of producing commercially attractive amounts of biomass in short rotations, but harvesting costs and logistics remain a concern. There is a particular need for information about harvesting operations on larger, commercial short–rotation woody crop systems. Another recent issue on commercial fields in northern New York is commercial growers conducting harvests during the growing season rather than the recommended dormant season when fields may be too wet to harvest. This study evaluated and modeled the in–field performance of a cut–and–chip harvester for almost 700 wagonloads of chips operating in commercial willow fields in a wider array of crop and field conditions than have been previously reported. Analysis indicated that the time of harvest (leaf–on or leaf–off) and whether site conditions were wet or dry affected the harvester's material capacity. Mean material capacity was greatest for leaf–off, dry conditions (71.8 Mg/hr) and lowest for leaf–on harvests, which were similar for wet (30.4 Mg/hr) and dry conditions (29.7 Mg/hr). Mean crop specific fuel consumption ranged between 1.3 and 3.3 L/Mg, but can get considerably higher for standing biomasses below 40 Mg/ha. Wet ground conditions and leaf–on harvests tend to decrease material capacity and increase fuel consumption as the harvester has to divert power to forward movement and material processing. Relationships for material capacity and fuel consumption based on standing biomass, time of harvest and ground conditions will be essential for evaluating and modeling the economic and environmental impacts of commercial–scale willow operations.

09 BIOMASS FUELS↗

Comparative Study of the Capacity and Rate Capability of LiNiyMnyCo1-2yO2 (y50.5 0.45 0.4 0.33)

An unresolved question for the layered oxides is: what is the optimum value of y in the formula LiNi{sub y}Mn{sub y}Co{sub 1-2y}O{sub 2} for energy storage at moderate reaction rates? Here we report a systematic study of the specific capacity, rate capability and cycle life of Li{sub x}Ni{sub y}Mn{sub y}Co{sub 1-2y}O{sub 2}(y = 0.5, 0.45, 0.4, and 0.333). The voltage of the Li/y = 0.333 couple crosses over those of lower cobalt content for x < 0.55, as the Co redox begins to get involved. This early involvement of cobalt, rather than just Ni, leads to a slightly smaller specific capacity for y = 0.333 than for LiNi{sub y}Mn{sub y}Co{sub 1-2y}O{sub 2} with y > 0.333 when charging above 4 V. Overall the y = 0.4 material has the optimum properties, having the highest theoretical capacity, less of the expensive cobalt and yet rate capabilities and capacity retention comparable to the y = 0.333 material.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Final Report: DE- FC36-05GO15063, Fundamental Studies of Advanced High-Capacity, Reversible Metal Hydrides

The project was component of the US DOE, Metal Hydride Center of Excellence (MHCoE). The Sandia National Laboratory led center was established to conduct highly collaborative and multi-disciplinary applied R&D to develop new reversible hydrogen storage materials that meet or exceed DOE/FreedomCAR 2010 and 2015 system targets for hydrogen storage materials. Our approach entailed a wide variety of activities ranging from synthesis, characterization, and evaluation of new candidate hydrogen storage materials; screening of catalysts for high capacity materials requiring kinetics enhancement; development of low temperature methods for nano-confinement of hydrides and determining its effects on the kinetics and thermodynamics of hydrides; and development of novel processes for the direct re-hydrogenation of materials. These efforts have resulted in several advancements the development of hydrogen storage materials. We have greatly extended the fundamental knowledge about the highly promising hydrogen storage carrier, alane (AlH 3 ), by carrying out the first crystal structure determinations and the first determination of the heats of dehydrogenation of β–AlH 3 and γ-AlD 3 . A low-temperature homogenous organometallic approach to incorporation of Al and Mg based hydrides into carbon aerogels has been developed that that allows high loadings without degradation of the nano-porous scaffold. Nano-confinement was found to significantly improve the dehydrogenation kinetics but not effect the enthalpy of dehydrogenation. We conceived, characterized, and synthesized a novel class of potential hydrogen storage materials, bimetallic borohydrides. These novel compounds were found to have many favorable properties including release of significant amounts of hydrogen at moderate temperatures (75-190 º C). However, in situ IR studies in tandem with thermal gravimetric analysis have shown that about 0.5 equivalents of diborane are released during the dehydrogenation making re-hydrogenation effectively impossible and precluding these compounds from further consideration as hydrogen storage materials. The hydrogen cycling of >11 wt % between MgB 2 to Mg(BH 4 ) 2 was achieved but required very forcing conditions. Under moderate conditions (dehydrogenation 200°C; re-hydrogenation 250°C, 120 atm H 2 ), Mg(BH 4 ) 2 undergoes reversible dehydrogenation to Mg(B 3 H 8 ) 2 . Although the 2.5 wt% cycling capacity does not meet current on-board storage targets, this result provides first example of direct hydrogen cycling of a borohydride under moderate conditions and demonstrates the plausibility of finding mild, PEM fuel cell relevant conditions for the high capacity, reversible dehydrogenation of borohydrides. A method was developed for the room temperature, direct hydrogenation of Ti-doped LiH/Al in liquefied dimethyl ether under 100 atm of H 2 . The process has been optimized such that Ti-doped LiAlH 4 is obtained in >95% yield. The WTT energy efficiency our direct synthesis process has been estimated to approach the 60% U.S. DOE target. Thus our simplification of the hydrogenation half-cycle may provide the key to harnessing the long-recognized potential of this lightweight, high capacity material as a practical hydrogen carrier. Finally, we have gained insight into the fundamental basis of the enhanced hydrogen cycling kinetics of Ti-doped NaAlH 4 through studies by solid state 1 H NMR, anelastic spectroscopy; muon spin rotation; and positron annihilation.

08 HYDROGEN↗

Determination of Adsorption Capacity and Kinetics of Amidoxime-Based Uranium Adsorbent Braided Material in Unfiltered Seawater Using a Flume Exposure System

PNNL has developed a recirculating flume system for exposing braided adsorbent material to natural seawater under realistic temperature and flow-rate exposure conditions. The flumes are constructed of transparent acrylic material; they allow external light to pass into the flumes and permit photosynthetic growth of naturally present marine organisms (biofouling). Because the system consists of two flumes, replicate experiments can be conducted in which one of the flumes can be manipulated relative to the other. For example, one flume can be darkened to eliminate light exposure by placing a black tarp over the flume such that dark/light experiments can be conducted. Alternatively, two different braided adsorbents can be exposed simultaneously with no potential cross contamination issues. This report describes the first use of the PNNL flume system to study the impact of biofouling on adsorbent capacity. Experiments were conducted with the ORNL AI8 braided adsorbent material in light-exposed and darkened flumes for a 42-day exposure experiment. The major objective of this effort is to develop a system for the exposure of braided adsorbent material to unfiltered seawater, and to demonstrate the system by evaluating the performance of adsorption material when it is exposed to natural marine biofouling as it would be when the technology is used in the marine environment. Exposures of amidoxime-based polymeric braid adsorbents prepared by Oak Ridge Natural Laboratory (ORNL) were exposed to ambient seawater at 20°C in a flume system. Adsorption kinetics and adsorption capacity were assessed using time series determinations of uranium adsorption and one-site ligand saturation modeling. Biofouling in sunlight surface seawater has the potential to significantly add substantial biogenic mass to adsorption material when it is exposed for periods greater than 21 days. The observed biomass increase in the light flume was approximately 80% of the adsorbent mass after 42 days. The amount of biomass increase retained by the adsorbent in the dark flume was only a quarter of that observed in the light-exposed flume. Biofouling in sunlit surface seawater has the potential to reduce uranium adsorption capacity by ~30% after 42 days of exposure. Minimal or no adsorption loss due to biofouling occurred in the dark flume exposure. Attempts to assess time series measurements of uranium adsorption capacity using “snips” off a master braid are fraught with problems due to the inability to easily determine the mass of the adsorbent material when the biofouling is present. The ability to determine the adsorption of biogenically important trace elements (e.g. Fe, Mn, Zn, Cu, and Sr) on biofouled adsorbents is also problematic.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Bounds on the Information Carrying Capacity of Pn Waves

Upper and lower bounds on the capacity of the Pn wave to transmit information about source identity are developed using models and measurements of Pn spatial signal structure across the ARCES array. The results show a very significant increase in information carrying capacity when contrasting observed propagation conditions with idealized free-space propagation. In essence, scattering greatly increases Pn channel capacity. As shown in a previous contribution, this increase in information can be captured with matched field calibrations and exploited to resolve sources more closely spaced than the Rayleigh resolution limit. These results mirror practices in cellular telephones that use arrays at the transmitter and receiver to exploit scattering for increased channel capacity.

58 GEOSCIENCES↗

Assessing Photovoltaic Capacity Factor Variability Using Long-Term Satellite Derived Solar Resource Data Under Brazilian Climate

Accurate estimation of photovoltaic (PV) energy yield and its variability is essential for reducing financial risk and supporting reliable system planning for rapidly expanding PV markets. In Brazil, high solar adoption and increasing levels of distributed energy resources are beginning to introduce operational challenges such as curtailment and evolving grid requirements. Understanding how natural variability in solar resource propagates into PV system performance is therefore increasingly important for both project design and grid integration. Modern PV yield assessments commonly rely on multi-year meteorological datasets and probabilistic exceedance metrics (e.g., P50/P90) to quantify energy yield uncertainty for project financing. However, the implications of long-term solar resource variability for PV system design choices and high-adoption grid conditions remain less well characterized for rapidly expanding markets such as Brazil. In particular, understanding how weather-driven variability propagates into PV production distributions and capacity factor expectations is important for evaluating curtailment exposure, deployment strategies, and storage requirements in regions experiencing rapid growth of distributed and utility-scale PV. Seasonal and interannual variability in atmospheric conditions can produce substantial fluctuations in monthly PV energy production, which propagate into uncertainty in annual energy yield and capacity factor expectations. Characterizing this variability using long-term meteorological datasets allows probabilistic estimation of PV system performance and provides improved insight into the range of expected PV energy outcomes. This study explores the use of long-term satellite-derived meteorological data from the National Solar Radiation Database (NSRDB) to evaluate the variability of photovoltaic system performance across multiple locations in Brazil. Using a 27-year dataset (1998-2024), PV system simulations are performed to characterize the distribution of annual and seasonal capacity factors and energy yield outcomes, while propagating key sources of meteorological variability and model uncertainty through the PV modeling chain. The analysis also investigates the sensitivity of PV performance outcomes to key system design assumptions within the PV modeling chain, including tracking configuration and system sizing parameters. The resulting probabilistic performance characterization provides insight into how weather-driven variability influences PV production expectations and capacity factor distributions. These results provide a foundation for evaluating how weather-driven variability interacts with high PV adoption and potential storage or curtailment mitigation strategies.

14 SOLAR ENERGY↗

Feasibility Studies as Catalysts for Capacity Building: The DEVELOP Experience from Local to National Scale

The NASA DEVELOP National Program occupies a unique niche in the capacity development ecosystem. It is not a traditional training or educational program primarily focused on individual capacity, nor is it a full-scale co-development program focused on institutional capacity. NASA DEVELOP conducts 10-week feasibility studies that bring together teams of participants and decision making partners. The participants are competitively selected students and emerging or transitioning professionals, who build their STEM and professional skillsets. The partners are groups that have decision making requirements that may benefit from insights that Earth observations can provide. The interaction of the participants and partners over the intense 10-week time period is especially well adapted to building capacity at smaller scales. DEVELOP projects have shown good results when working at municipal and smaller administrative levels like U.S. counties. Even when working with higher administrative levels like provinces, U.S states, or even national or federal levels, DEVELOP has shown most success when working with more localized institutions like state forests or national parks. This presentation will recount case studies of how DEVELOP projects worked with more local or “localized” partners and compare with outcomes with partners at other scales: state/provincial and federal/national levels.

Capacity Building↗

Multi-User Capacity for Cyclic Prefix Direct Sequence Spread Spectrum with Linear Detection and Precoding

Cyclic Prefix Direct Sequence Spread Spectrum (CP-DSSS) is a promising solution for futuristic 6G ultra-reliable low latency communications (URLLC) and massive machine type communication (mMTC) applications, where the CP-DSSS waveform would operate as a secondary network at the same frequencies as the primary network but at much lower SNR. In this paper, we show per-user capacity for multi-user scenarios, where simple matched filtering (MF) is performed on the uplink (UL) and time-reversal (TR) precoding is used on the downlink (DL). When operating in the low SNR regime, CP-DSSS achieves per-user capacity near the optimum single-user capacity by using a MF detector at the receiver for the UL. TR precoding converges to the optimal capacity as the number of antennas at the hub/gateway increases. Given the near-optimal performance of MF detection and TR precoding for each of the users, CP-DSSS can be implemented with simple device transceiver structures, reducing per-unit cost for massively deployed 6G networks.

5G and Beyond Communications↗

PV Hosting Capacity Estimation: Experiences with Scalable Framework; Preprint

Hosting capacity is an indication of the amount of photovoltaics (PV) can be hosted in a distribution system. This paper presents a framework for estimating distributed PV hosting capacity at scale. We first analyze the key challenges of performing relevant large scale simulation including computational and modeling challenges. Then, we develop two python-based software tools in order to conduct repeatable distribution analyses: Distribution Integration Solution Cost Options (DISCO) for configuring and analyzing simulations, and JADE for parallelizing jobs on HPC clusters. A case study of hosting capacity estimation for SMART-DS SFO 2000+ synthetic feeders is used to demonstrate the capability of the developed framework and tools. The framework and tools can help utilities assess the overall hosting capacity of their service territory, through which the overall upgrade cost can be better planned in order to integrate more PV in the future.

distributed energy resources↗

Multicriterion Benefit Evaluation of Deploying New Battery Technology with Increased Capacity at a Generic Nuclear Power

Nuclear power plant (NPP) safety improvements are routinely made by plant licensees and regulators. Examples of plant improvements include accident-tolerant fuel, diverse and flexible coping strategies, passive cooling systems, and increased battery capacity. A combined use of these plant improvements could lead to plant designs with enhanced resilience, allowing NPPs to better cope with both internal and external hazards and keep the plant operating safely, efficiently, and economically. This paper focuses on increased battery capacity and evaluates the potential costs and benefits of deploying batteries with increased capacities at a generic boiling water reactor (BWR) NPP. A multicriterion benefit evaluation methodology is used for the cost-benefit analysis. Ten alternatives for extending battery capacity are developed, including nine alternatives to provide additional direct-current power and one alternative to provide additional alternating-current power. Potential benefits of reducing plant risk are quantified through incorporating the alternatives into loss-of-offsite-power scenarios of the generic BWR probabilistic risk assessment model. Potential costs of implementing the alternatives are qualitatively discussed and ranked. The alternatives are then compared based on their impacts on plant risk and economics.

99 GENERAL AND MISCELLANEOUS↗

Multicriterion Benefit Evaluation of Deploying New Battery Technology with Increased Capacity at a Generic Nuclear Power Plant

This presentation is prepared for the DOE LWRS RISA Pathway Stakeholder Engagement Meeting on October 13-14, 2021. Nuclear power plant (NPP) safety improvements are routinely made by plant licensees and regulators. Examples of plant improvements include accident-tolerant fuel, diverse and flexible coping strategies, passive cooling systems, and increased battery capacity. A combined use of these plant improvements could lead to plant designs with enhanced resilience, allowing NPPs to better cope with both internal and external hazards and keep the plant operating safely, efficiently, and economically. This presentation focuses on increased battery capacity and evaluates the potential costs and benefits of deploying batteries with increased capacities at a generic boiling water reactor (BWR) NPP. A multicriterion benefit evaluation methodology is used for the cost-benefit analysis. Ten alternatives for extending battery capacity are developed, including eight alternatives to provide additional direct-current power and one alternative to provide additional alternating-current power. Potential benefits of reducing plant risk are quantified through incorporating the alternatives into loss-of-offsite-power scenarios of the generic BWR probabilistic risk assessment model. Potential costs of implementing the alternatives are qualitatively discussed and ranked. The alternatives are then compared based on their impacts on plant risk and economics.

99 GENERAL AND MISCELLANEOUS↗

Soil pH Buffering Capacity, Geochemical Characterization, and Soil Water Retention for Arctic Soils of Seward Peninsula and Utqiagvik, Alaska, 2013-2019

This dataset provides pH titration data and soil pH buffering capacities of 21 Arctic soils that were collected between 2013-2019. Geochemical data including soil organic carbon, carbon:nitrogen ratio, initial pH, and gravimetric water content are also reported. Additional measurements of cation exchange capacity and soil water retention (dry range) are presented for selected soils. A script, developed in R, is also included for a simple biogeochemical simulation that incorporates soil pH buffering capacity. This dataset contains 7 csv files and one R script.The Next-Generation Ecosystem Experiments: Arctic (NGEE Arctic), was a research effort to reduce uncertainty in Earth System Models by developing a predictive understanding of carbon-rich Arctic ecosystems and feedbacks to climate. NGEE Arctic was supported by the Department of Energy's Office of Biological and Environmental Research.The NGEE Arctic project had two field research sites: 1) located within the Arctic polygonal tundra coastal region on the Barrow Environmental Observatory (BEO) and the North Slope near Utqiagvik (Barrow), Alaska and 2) multiple areas on the discontinuous permafrost region of the Seward Peninsula north of Nome, Alaska.Through observations, experiments, and synthesis with existing datasets, NGEE Arctic provided an enhanced knowledge base for multi-scale modeling and contributed to improved process representation at global pan-Arctic scales within the Department of Energy's Earth system Model (the Energy Exascale Earth System Model, or E3SM), and specifically within the E3SM Land Model component (ELM).

54 ENVIRONMENTAL SCIENCES↗

An Ultrahigh Capacity Graphite/Li 2 S Battery with Holey-Li 2 S Nanoarchitectures

The pairing of high-capacity Li 2 S cathode (1166 mAh g -1 ) and lithium-free anode (LFA) provides an unparalleled potential in developing safe and energy-dense next-generation secondary batteries. However, the low utilization of the Li 2 S cathode and the lack of electrolytes compatible to both electrodes are impeding the development. Here, a novel graphite/Li 2 S battery system, which features a self-assembled, holey-Li 2 S nanoarchitecture and a stable solid electrolyte interface (SEI) on the graphite electrode, is reported. The holey structure on Li 2 S is beneficial in decomposing Li 2 S at the first charging process due to the enhanced Li ion extraction and transfer from the Li 2 S to the electrolyte. In addition, the concentrated dioxolane (DOL)-rich electrolyte designed lowers the irreversible capacity loss for SEI formation. By using the combined strategies, the graphite/holey-Li 2 S battery delivers an ultrahigh discharge capacity of 810 mAh g -1 at 0.1 C (based on the mass of Li 2 S) and of 714 mAh g -1 at 0.2 C. Moreover, it exhibits a reversible capacity of 300 mAh g -1 after a record lifecycle of 600 cycles at 1 C. These results suggest the great potential of the designed LFA/holey-Li 2 S batteries for practical use.

25 ENERGY STORAGE↗

High Sulfur Loading and Capacity Retention in Bilayer Garnet Sulfurized‐Polyacrylonitrile/Lithium‐Metal Batteries with Gel Polymer Electrolytes

The cubic‐garnet (Li 7 La 3 Zr 2 O 12 , LLZO) lithium–sulfur battery shows great promise in the pursuit of achieving high energy densities. The sulfur used in the cathodes is abundant, inexpensive, and possesses high specific capacity. In addition, LLZO displays excellent chemical stability with Li metal; however, the instabilities in the sulfur cathode/LLZO interface can lead to performance degradation that limits the development of these batteries. Therefore, it is critical to resolve these interfacial challenges to achieve stable cycling. Here, an innovative gel polymer buffer layer to stabilize the sulfur cathode/LLZO interface is created. Employing a thin bilayer LLZO (dense/porous) architecture as a solid electrolyte and significantly high sulfur loading of 5.2 mg cm −2 , stable cycling is achieved with a high initial discharge capacity of 1542 mAh g −1 (discharge current density of 0.87 mA cm −2 ) and an average discharge capacity of 1218 mAh g −1 (discharge current density of 1.74 mA cm −2 ) with 80% capacity retention over 265 cycles, at room temperature (22 °C) and without applied pressure. Achieving such stability with high sulfur loading is a major step in the development of potentially commercial garnet lithium–sulfur batteries.

25 ENERGY STORAGE↗