Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “calibration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

Air kerma standard for calibration of well-type chambers in Brazil using {sup 192}Ir HDR sources and its traceability

In Brazil there are over 100 high dose rate (HDR) brachytherapy facilities using well-type chambers for the determination of the air kerma rate of {sup 192}Ir sources. This paper presents the methodology developed and extensively tested by the Laboratorio de Ciencias Radiologicas (LCR) and presently in use to calibrate those types of chambers. The system was initially used to calibrate six well-type chambers of brachytherapy services, and the maximum deviation of only 1.0% was observed between the calibration coefficients obtained and the ones in the calibration certificate provided by the UWADCL. In addition to its traceability to the Brazilian National Standards, the whole system was taken to University of Wisconsin Accredited Dosimetry Calibration Laboratory (UWADCL) for a direct comparison and the same formalism to calculate the air kerma was used. The comparison results between the two laboratories show an agreement of 0.9% for the calibration coefficients. Three Brazilian well-type chambers were calibrated at the UWADCL, and by LCR, in Brazil, using the developed system and a clinical HDR machine. The results of the calibration of three well chambers have shown an agreement better than 1.0%. Uncertainty analyses involving the measurements made both at the UWADCL and LCR laboratories are discussed.

61 RADIATION PROTECTION AND DOSIMETRY↗

Sensitivity analysis of a geometric calibration method using projection matrices for digital tomosynthesis systems

Purpose: To study the sensitivity of a geometric calibration method using projection matrices for digital tomosynthesis systems. Methods: A generic geometric calibration method for tomographic imaging systems has been presented in our previous work. The method involves a scan of a calibration phantom with multiple markers. Their locations in projection images are detected and are associated with their 3D coordinates to compute 3x4 projection matrices, which can be used in subsequent image reconstruction. The accuracy of geometric calibration may be affected by errors in the input data of marker positions. The effects of errors may depend on the number of markers and the volume surrounded by them in 3D space. This work analyzed the sensitivity of the calibration method to the above factors. A 6 cm CIRS breast research phantom and a prototype breast tomosynthesis system were used for our tests. A high contrast ring and two small speck groups were reconstructed in various testing cases for comparison. To achieve quantitative assessment, a 15x15 point detection mask was adopted for detecting signals and for computing changes between testing cases and the regular geometric calibration. Results: When 3D coordinates and 2D projections of markers were accurate, all tested numbers of markers, 6-44, provided similar high quality reconstructions of the ring and the two speck groups. Errors in marker positions resulted in image degradations and signal changes, which increased with fewer markers and smaller volume surrounded by markers in the 3D object space. Signal changes of small specks were more significant than those of the ring. Errors in marker projections produced drastic image degradations. Coplanar marker placement caused a failure in projection matrix computation. Conclusions: For practical geometric calibration phantom design, ample markers are desired. They need to have a large volumetric coverage in the 3D space and be far from being coplanar. Precise determination of marker projections on detector planes is crucial for accurate geometric calibration and for small object detection using the reconstructed images.

60 APPLIED LIFE SCIENCES↗

Automated intraoperative calibration for prostate cancer brachytherapy

Purpose: Prostate cancer brachytherapy relies on an accurate spatial registration between the implant needles and the TRUS image, called ''calibration''. The authors propose a new device and a fast, automatic method to calibrate the brachytherapy system in the operating room, with instant error feedback. Methods: A device was CAD-designed and precision-engineered, which mechanically couples a calibration phantom with an exact replica of the standard brachytherapy template. From real-time TRUS images acquired from the calibration device and processed by the calibration system, the coordinate transformation between the brachytherapy template and the TRUS images was computed automatically. The system instantly generated a report of the target reconstruction accuracy based on the current calibration outcome. Results: Four types of validation tests were conducted. First, 50 independent, real-time calibration trials yielded an average of 0.57 {+-} 0.13 mm line reconstruction error (LRE) relative to ground truth. Second, the averaged LRE was 0.37 {+-} 0.25 mm relative to ground truth in tests with six different commercial TRUS scanners operating at similar imaging settings. Furthermore, testing with five different commercial stepper systems yielded an average of 0.29 {+-} 0.16 mm LRE relative to ground truth. Finally, the system achieved an average of 0.56 {+-} 0.27 mm target registration error (TRE) relative to ground truth in needle insertion tests through the template in a water tank. Conclusions: The proposed automatic, intraoperative calibration system for prostate cancer brachytherapy has achieved high accuracy, precision, and robustness.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Humidity effects on calibrations of radiation therapy electrometers

Purpose: To eliminate variation in electrometer calibration results caused by high humidity and suboptimal connectors on the standard capacitors and to implement hardware that prevents overloading of the input stage of electrometers during calibration. Methods: A humidity-controlled cabinet was installed to provide a low-humidity environment for the standard capacitors. All of the coaxial BNC connections were replaced with Triax (TRB) connectors with the exception of the output from the voltage source. A three-stage RC filter with cascaded RC low-pass sections was designed and tested. Results: The installation of the humidity cabinet resulted in a major improvement in the stability and reproducibility of the electrometer calibration system. For the three years since this upgrade, the Ionizing Radiation Standards (IRS) electrometer calibration results have been consistent regardless of the ambient relative humidity in the lab. The connector replacements improved grounding in the calibration circuit. The three-stage filter allows the voltage at the output to rise in an S-shaped waveform, resulting in a smooth rise of the current through the isolation resistor from zero and back again, with no abrupt transition. For the filter design chosen, 99.99% of the charge is delivered within 6 s. Conclusions: A three-way improvement to the calibration measurement system was successful in eliminating the observed variations, resulting in an electrometer calibration measurement system that is unaffected by humidity and allowing reliable year-round calibrations of any electrometer encountered since the implementation of these changes.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Water-equivalent path length calibration of a prototype proton CT scanner

Purpose: The authors present a calibration method for a prototype proton computed tomography (pCT) scanner. The accuracy of these measurements depends upon careful calibration of the energy detector used to measure the residual energy of the protons that passed through the object. Methods: A prototype pCT scanner with a cesium iodide (CsI(Tl)) crystal calorimeter was calibrated by measuring the calorimeter response for protons of 200 and 100 MeV initial energies undergoing degradation in polystyrene plates of known thickness and relative stopping power (RSP) with respect to water. Calibration curves for the two proton energies were obtained by fitting a second-degree polynomial to the water-equivalent path length versus calorimeter response data. Using the 100 MeV calibration curve, the RSP values for a variety of tissue-equivalent materials were measured and compared to values obtained from a standard depth-dose range shift measurement using a water-tank. A cylindrical water phantom was scanned with 200 MeV protons and its RSP distribution was reconstructed using the 200 MeV calibration. Results: It is shown that this calibration method produces measured RSP values of various tissue-equivalent materials that agree to within 0.5% of values obtained using an established water-tank method. The mean RSP value of the water phantom reconstruction was found to be 0.995 {+-} 0.006. Conclusions: The method presented provides a simple and reliable procedure for calibration of a pCT scanner.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-T-470: Importance of HU-Mass Density Calibration Technique in Proton Pencil Beam Dose Calculation

Purpose: Stoichiometric calibration of Hounsfield Units (HUs) for conversion to proton relative stopping powers (RStPs) is vital for accurate dose calculation in proton therapy. However proton dose distributions are not only dependent on RStP, but also on relative scattering power (RScP) of patient tissues. RScP is approximated from material density but a stoichiometric calibration of HU-density tables is commonly neglected. The purpose of this work was to quantify the difference in calculated dose of a commercial TPS when using HU-density tables based on tissue substitute materials and stoichiometric calibrated ICRU tissues. Methods: Two HU-density calibration tables were generated based on scans of the CIRS electron density phantom. The first table was based directly on measured HU and manufacturer quoted density of tissue substitute materials. The second was based on the same CT scan of the CIRS phantom followed by a stoichiometric calibration of ICRU44 tissue materials. The research version of Pinnacle{sup 3} proton therapy was used to compute dose in a patient CT data set utilizing both HU-density tables. Results: The two HU-density tables showed significant differences for bone tissues; the difference increasing with increasing HU. Differences in density calibration table translated to a difference in calculated RScP of −2.5% for ICRU skeletal muscle and 9.2% for ICRU femur. Dose-volume histogram analysis of a parallel opposed proton therapy prostate plan showed that the difference in calculated dose was negligible when using the two different HU-density calibration tables. Conclusion: The impact of HU-density calibration technique on proton therapy dose calculation was assessed. While differences were found in the calculated RScP of bony tissues, the difference in dose distribution for realistic treatment scenarios was found to be insignificant.

60 APPLIED LIFE SCIENCES↗

A new form of the calibration curve in radiochromic dosimetry. Properties and results

Purpose: This work describes a new form of the calibration curve for radiochromic dosimetry that depends on one fit parameter. Some results are reported to show that the new curve performs as well as those previously used and, more importantly, significantly reduces the dependence on the lot of films, the film orientation on the scanner, and the time after exposure. Methods: The form of the response curve makes use of the net optical densities ratio against the dose and has been studied by means of the Beer–Lambert law and a simple modeling of the film. The new calibration curve has been applied to EBT3 films exposed at 6 and 15 MV energy beams of linear accelerators and read-out in transmission mode by means of a flatbed color scanner. Its performance has been compared to that of two established forms of the calibration curve, which use the optical density and the net optical density against the dose. Four series of measurements with four lots of EBT3 films were used to evaluate the precision, accuracy, and dependence on the time after exposure, orientation on the scanner and lot of films. Results: The new calibration curve is roughly subject to the same dose uncertainty, about 2% (1 standard deviation), and has the same accuracy, about 1.5% (dose values between 50 and 450 cGy), as the other calibration curves when films of the same lot are used. Moreover, the new calibration curve, albeit obtained from only one lot of film, shows a good agreement with experimental data from all other lots of EBT3 films used, with an accuracy of about 2% and a relative dose precision of 2.4% (1 standard deviation). The agreement also holds for changes of the film orientation and of the time after exposure. Conclusions: The dose accuracy of this new form of the calibration curve is always equal to or better than those obtained from the two types of curves previously used. The use of the net optical densities ratio considerably reduces the dependence on the lot of films, the landscape/portrait orientation, and the time after exposure. This form of the calibration curve could become even more useful with new optical digital devices using monochromatic light.

60 APPLIED LIFE SCIENCES↗

FY07 Final Report for Calibration Systems

Remote infrared (IR) sensing provides a valuable method for detection and identification of materials associated with nuclear proliferation. Current challenges for remote sensors include minimizing the size, mass, and power requirements for cheaper, smaller, and more deployable instruments without affecting the measurement performance. One area that is often overlooked is sensor calibration design that is optimized to minimize the cost, size, weight, and power of the payload. Yet, an on-board calibration system is essential to account for changes in the detector response once the instrument has been removed from the laboratory. The Calibration Systems project at Pacific Northwest National Laboratory (PNNL) is aimed towards developing and demonstrating compact quantum cascade (QC) laser-based calibration systems for infrared sensor systems in order to provide both a spectral and radiometric calibration while minimizing the impact on the instrument payload. In FY05, PNNL demonstrated a multi-level radiance scheme that provides six radiance levels for an enhanced linearity check compared to the currently accepted two-point scheme. PNNL began testing the repeatability of this scheme using a cryogenically cooled, single-mode quantum cascade laser (QCL). A cyclic variation in the power was observed that was attributed to the thermal cycling of the laser's dewar. In FY06, PNNL continued testing this scheme and installed an auxiliary liquid nitrogen reservoir to limit the thermal cycling effects. Although better repeatability was achieved over a longer time period, power fluctuations were still observed due to the thermal cycling. Due to the limitations with the cryogenic system, PNNL began testing Fabry-Perot QCLs that operate continuous-wave (cw) or quasi-cw at room temperature (RT) in FY06. PNNL demonstrated a multi-level scheme that provides five radiance levels in 105 seconds with excellent repeatability. We have continued testing this repeatability in FY07. A burn-in effect appears in which the power increases over a certain time period. Repeatability better than 1%, however, is demonstrated for most of the radiance levels after this initial burn-in. In FY06, PNNL also began investigating a fiber-coupled RT QCL for a compact IR calibration source. PNNL demonstrated a uniform beam profile by measuring a time-averaged response and modulating the fiber optic with a motor to minimize the effects of speckle. In FY07, PNNL examined the power stability of fiber-coupled QCLs. Feedback appears to degrade the stability so that anti-reflective coatings for fibers may be essential. In FY07, PNNL continued to investigate the stability of room temperature QCLs as well as the measurement technique to provide a quantitative estimate for the measurement uncertainty. We designed and built a custom environmental enclosure to reduce the measurement uncertainty. After an initial burn-in, we have achieved uncertainties better than 0.1% for data collected over almost 100 hours of operation. We also built a bench-top system to demonstrate how the QC laser can be used to calibrate a microbolometer array and illustrated the importance of a multi-point calibration.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Photometric calibrations for 21st century science

The answers to fundamental science questions in astrophysics, ranging from the history of the expansion of the universe to the sizes of nearby stars, hinge on our ability to make precise measurements of diverse astronomical objects. As our knowledge of the underlying physics of objects improves along with advances in detectors and instrumentation, the limits on our capability to extract science from measurements is set, not by our lack of understanding of the nature of these objects, but rather by the most mundane of all issues: the precision with which we can calibrate observations in physical units. In principle, photometric calibration is a solved problem - laboratory reference standards such as blackbody furnaces achieve precisions well in excess of those needed for astrophysics. In practice, however, transferring the calibration from these laboratory standards to astronomical objects of interest is far from trivial - the transfer must reach outside the atmosphere, extend over 4{pi} steradians of sky, cover a wide range of wavelengths, and span an enormous dynamic range in intensity. Virtually all spectrophotometric observations today are calibrated against one or more stellar reference sources, such as Vega, which are themselves tied back to laboratory standards in a variety of ways. This system's accuracy is not uniform. Selected regions of the electromagnetic spectrum are calibrated extremely well, but discontinuities of a few percent still exist, e.g., between the optical and infrared. Independently, model stellar atmospheres are used to calibrate the spectra of selected white dwarf stars, e.g. the HST system, but the ultimate accuracy of this system should be verified against laboratory sources. Our traditional standard star systems, while sufficient until now, need to be improved and extended in order to serve future astrophysics experiments. This white paper calls for a program to improve upon and expand the current networks of spectrophotometrically calibrated stars to provide precise calibration with an accuracy of equal to and better than 1% in the ultraviolet, visible and near-infrared portions of the spectrum, with excellent sky coverage and large dynamic range.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Overview of SIM wide angle astrometric system calibration strategies

This paper summarizes two very different strategies envisioned for calibrating the systematic field dependent biases present in the Space Interferometry Mission (SIM) instrument. The Internal Calibration strategy is based on pre-launch measurements combined with a set of on orbit measurements generated by a source internal to the instrument. The External Calibration strategy uses stars as an external source for generating the calibration function. Both approaches demand a significant amount of innovation given that SIM's calibration strategy requires a post-calibration error of 100picometers over a 15 degree field of regard while the uncalibrated instrument introduces 10's-100's of nanometers of error. The calibration strategies are discussed in the context of the Wide Angle Astrometric mode of the instrument, although variations on the Internal Calibration Strategy may be used for doing Narrow Angle Astrometry.

calibration SIM optical modeling↗

On the Long-Term Stability of Microwave Radiometers Using Noise Diodes for Calibration

Results are presented from the long-term monitoring and calibration of the National Aeronautics and Space Administration Jason Microwave Radiometer (JMR) on the Jason-1 ocean altimetry satellite and the ground-based Advanced Water Vapor Radiometers (AWVRs) developed for the Cassini Gravity Wave Experiment. Both radiometers retrieve the wet tropospheric path delay (PD) of the atmosphere and use internal noise diodes (NDs) for gain calibration. The JMR is the first radiometer to be flown in space that uses NDs for calibration. External calibration techniques are used to derive a time series of ND brightness for both instruments that is greater than four years. For the JMR, an optimal estimator is used to find the set of calibration coefficients that minimize the root-mean-square difference between the JMR brightness temperatures and the on-Earth hot and cold references. For the AWVR, continuous tip curves are used to derive the ND brightness. For the JMR and AWVR, both of which contain three redundant NDs per channel, it was observed that some NDs were very stable, whereas others experienced jumps and drifts in their effective brightness. Over the four-year time period, the ND stability ranged from 0.2% to 3% among the diodes for both instruments. The presented recalibration methodology demonstrates that long-term calibration stability can be achieved with frequent recalibration of the diodes using external calibration techniques. The JMR PD drift compared to ground truth over the four years since the launch was reduced from 3.9 to - 0.01 mm/year with the recalibrated ND time series. The JMR brightness temperature calibration stability is estimated to be 0.25 K over ten days.

noise diode (ND)↗

Comparison of Spectral Radiance Calibration Techniques Used for Backscatter Ultraviolet Satellite Instruments

Methods for determining the absolute radiometric calibration sensitivities of backscatter ultraviolet (BUV) satellite instruments are compared as part of an effort to minimize pre-launch calibration errors. An internally illuminated integrating sphere source has been used for the Shuttle Solar BUV (SSBUV), Total Ozone Mapping Spectrometer (TOMS), Ozone Mapping Instrument (OMI), and Global Ozone Monitoring Experiment 2 (GOME-2) using standardized procedures traceable to national standards. These sphere-based sensitivities agree to within three percent [k equals 2] relative to calibrations performed using an external diffuser illuminated by standard irradiance sources, the customary radiance calibration method for BUV instruments. The uncertainty for these calibration techniques as implemented at the NASA Goddard Space Flight Centers Radiometric Calibration and Development Laboratory is shown to be 4 percent at 250nm [k equals 2] when using a single traceable calibration standard. Significant reduction in the uncertainty of nearly 1 percent is demonstrated when multiple calibration standards are used.

residual errors↗

Detection of Unexpected High Correlations between Balance Calibration Loads and Load Residuals

An algorithm was developed for the assessment of strain-gage balance calibration data that makes it possible to systematically investigate potential sources of unexpected high correlations between calibration load residuals and applied calibration loads. The algorithm investigates correlations on a load series by load series basis. The linear correlation coefficient is used to quantify the correlations. It is computed for all possible pairs of calibration load residuals and applied calibration loads that can be constructed for the given balance calibration data set. An unexpected high correlation between a load residual and a load is detected if three conditions are met: (i) the absolute value of the correlation coefficient of a residual/load pair exceeds 0.95; (ii) the maximum of the absolute values of the residuals of a load series exceeds 0.25 % of the load capacity; (iii) the load component of the load series is intentionally applied. Data from a baseline calibration of a six-component force balance is used to illustrate the application of the detection algorithm to a real-world data set. This analysis also showed that the detection algorithm can identify load alignment errors as long as repeat load series are contained in the balance calibration data set that do not suffer from load alignment problems.

strain-gage balance↗

Evaluation of Long-Term Calibrations of the AVHRR Visible Radiances

Two systematic calibrations have been compiled for the visible radiances measured by the series of AVHRR instruments flown on the NOAA operational polar weather satellites: one by the International Satellite Cloud Climatology Project (ISCCP), anchored on NASA ER-2 underflights in the 1980s and early 1990s and covering the period 1981-2009, and one by the PATMOS-x project, anchored on comparisons to the MODIS instruments on the Aqua and Terra satellites in the 2000s and covering the period 1979-2010 (this result also includes calibration for the near-IR channels). Both methods have had to extend their anchor calibrations over a long series of instruments using different vicarious approaches, so a comparison provides an opportunity to evaluate how well this extension works by cross-checking the results at the anchor points. The basic result of this comparison is that for the ''afternoon'' series of AVHRRs, the calibrations agree to within their mutual uncertainties. However, this retrospective evaluation also shows that the representation of the time variations can be simplified. The ISCCP procedure had much more difficulty extending the calibration to the ''morning'' series of AVHRRs with the calibrations for NOAA-15 and NOAA-17 exceeding the estimated uncertainties. Given the general agreement, a new calibration for all AVHRR visible radiances (except TIROS-N, NOAA-6, NOAA-19, and MetOp-A) is proposed that is based on the average of the best linear fits to the two time records. The estimated uncertainty of these calibrations is 63% absolute (scaled radiance units).

Advanced Very High Resolution Radiometer↗

Application of quasi-deep convective clouds method for MODIS and VIIRS TEB calibration assessments

A technique to use deep convective clouds (DCC) and quasi-DCC (qDCC) for the calibration assessment of the thermal emissive bands (TEB) on remote sensing instruments has proven feasible. The Terra and Aqua MODIS and S-NPP and NOAA-20 VIIRS TEB calibration uses a nonlinear algorithm whose nonlinear coefficients rely on on-orbit black body (BB) warm-up and cool-down (WUCD) activities for updates. However, the limited BB temperature range affects the calibration’s uncertainty. The DCC core, one of the coldest Earth scenes, is suitable for MODIS calibration assessments; more specifically, for the evaluation of the offset effect in its TEB quadratic calibration function. Moreover, nighttime qDCC measurements provide the advantage of removing solar reflectance effects, thus enhancing the assessment’s accuracy for the midwave infrared TEB. In this paper, the qDCC method is applied to the Terra MODIS and VIIRS TEB. Their stabilities are assessed using long-term DCC and qDCC trending measurements over the instruments’ entire missions. The measurements from bands with an approximately 11-μm wavelength are used to identify the DCC pixels. MODIS band31 (~ 11m) has demonstrated stable performance and accurate calibration for both instruments throughout their respective missions. MODIS band31 can therefore be used as a reference for the other TEB. Furthermore, it also allows for a Terra and Aqua MODIS TEB cross-comparison. The assessment results, along with the calibration uncertainty and Level 1B product impact modeling, can be quite helpful for calibration improvements.

MODIS↗

MODIS TEB Calibration Algorithm Improvements for Future L1B Collection

Terra and Aqua MODIS have provided continuous global observations for scientific applications for more than 20 and 18 years, respectively. The radiometric calibration of the MODIS thermal emissive bands (TEB) is based on a quadratic approximation of the instrument response. The calibration coefficients look-up tables (LUTs) are updated using the response of the MODIS on-board blackbody (BB)with the response background subtracted by space view. The quarterly on-board BB warm-up and cool-down activity temperature ranges from 270 K to 315 K, and the derived offset has a relatively large uncertainty. Electronic cross-talk, an artifact that affects both instrument calibration and Earth view (EV) radiance retrievals, is corrected based on lunar observations. Calibration assessments using EV observations (e.g. ocean, desert, Antarctic Dome Concordia, and deep convective clouds) provide useful information to evaluate the impact of the Terra safe mode (February 2016) and Aqua MODIS formatter reset (January 2018) events on both MODIS instruments. This study focuses on the TEB radiometric calibration algorithm improvements for future collections based on calibration assessments using EV measurements and analytical modeling. Measurement stability and consistency over specific Earth scenes with a wide temperature range, as well as their brightness temperature (BT) dependency, are used for bias estimations in the calibration coefficients. Calibration coefficients are derived and updated after adjusting the current fitting algorithm. Thereafter, using the test LUTs, their impact on the Level 1B (L1B) data for different EV scenes is analyzed.

MODIS↗

Overview of GSICS visible calibration methods.

Global Space-based Inter-Calibration System (GSICS) is an international collaborative effort initiated in 2005 by the World Meteorological Organization (WMO) and the Coordination Group for Meteorological Satellites (CGMS) to 1-monitor, 2-improve and 3-harmonize the quality of observations from operational weather and environmental satellites of the Global Observing System (GOS). GSICS aims at ensuring consistent accuracy among space-based observations worldwide for climate monitoring, weather forecasting, and environmental applications by 1-monitoring instrument performance, 2-operational inter-calibration of satellite instruments, 3-radiometrically scaling observations to absolute reference standards, 4-recalibration of archived datasets. Although many of the GSIC visible inter-calibration methods are based on medium pixel-level imagers such as MODIS, VIIRS, AVHRR, and geostationary sensors, the methods are applicable to high spatial resolution imagery such as Landsat. For sensor inter-calibration efforts, coincident ray-matched reflectance pairs are used to transfer the calibration from the reference to the target instrument. Spectral band adjustment factors (SBAF) are applied to account for any spectral band differences. For sensor stability monitoring, PICS, deep convective cloud (DCC) and polar ice Earth viewed targets are utilized. GSICS uses the moon for stability monitoring by using the GSICS Implementation of the USGS Robotic Lunar Observatory (ROLO) model (GIRO). GSICS is looking forward to the launch of CLARREO on the international space station (ISS) in 2023. The CLARREO hyperspectral reflective solar band (RSB) sensor will establish an absolute calibration reference in space, which will characterize invariant targets and will inter-calibrate concurrent sensors. Examples of these calibration methods will be presented at the workshop.

Visible calibration methods↗

Application of Quasi-Deep Convective Clouds Method for VIIRS and MODIS TEB Calibration Assessments

A technique that utilizes quasi-deep convective clouds (qDCC) for the calibration assessment of the thermal emissive bands (TEB) on remote sensing instruments has been proven viable. The Terra and Aqua MODIS and S-NPP and NOAA-20 VIIRS TEB calibration uses a nonlinear algorithm whose nonlinear coefficients rely on on-orbit blackbody (BB) warm-up and cooldown operations for updates. However, a limited BB temperature range affects the calibration’s accuracy particularly for cold scenes. The deep convective clouds (DCC) core, one of the coldest Earth scenes, is suitable for MODIS calibration assessments; more specifically, for the evaluation of the offset term’s effect in its TEB quadratic calibration function. Moreover, nighttime qDCC measurements provide with the advantage of removing solar reflectance effects during daytime, thus enhancing the assessment’s accuracy for the midwave infrared TEB. In this paper, this qDCC method is applied to the Terra MODIS and VIIRS TEB; and their stabilities are assessed using long-term qDCC trending measurements over the instruments’ missions. The measurements from bands with an 11-μm wavelength are used to identify the DCC pixels. The 11-μm bands, MODIS band 31 and VIIRS bands M15 and I5, are stable throughout the MODIS and VIIRS missions and have shown excellent calibration accuracy and noise performance. Hence, using these bands as references, a normalization method is employed to enhance the accuracy of the stability and consistency assessments. The S-NPP VIIRS TEB show stable trends over the instrument’s mission. The S-NPP-to-N20 VIIRS comparison shows their TEB measurements are consistent over qDCC. The Terra MODIS TEB also show stable performance – except for bands 27, 29, and 30. Terra MODIS band 30 shows a large downward trend throughout the mission, while bands 27 and 29 show slight, upward drifts. Lastly, a calibration correction using qDCC assessments is discussed and intended to be used in a future calibration algorithm collection.

MODIS↗