Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “calculation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

Monte-Carlo Method of Calculating Weakly Coupled Systems Using the PRIZMA-DSP Code

A Monte Carlo method implemented in the PRIZMA-DSP code to calculate multiplying systems, including weakly coupled systems, is described. In the code, the basis of the method is a sequential calculation of a prescribed chain of active generations, which is described by, first and foremost, the dominant ratio of the system. The fission points of the running generation serve as a source for constructing neutron trajectories, new fission points arising on a trajectory are transmitted unchanged to calculate the next generation, and so on. In the calculation of the active generation, K{sub eff} and made-to-order linear-fractional functions are evaluated. In order for the distribution to become established, a passive calculation with prescribed chain length is made before the active calculation. In addition, after the calculation of each generation the operation of random mixing of the entire set of fission points and their distribution over the nuclei is performed in order to obtain a uniform distribution. At the start of the calculation, a special rejection procedure performs a pre-set number of preliminary computational iterations so that an arbitrary zeroth distribution over all nuclei goes to a distribution obtained via a characteristic function.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Verification of Calculated Skin Doses in Postmastectomy Helical Tomotherapy

Purpose: To verify the accuracy of calculated skin doses in helical tomotherapy for postmastectomy radiation therapy (PMRT). Methods and Materials: In vivo thermoluminescent dosimeters (TLDs) were used to measure the skin dose at multiple points in each of 14 patients throughout the course of treatment on a TomoTherapy Hi.Art II system, for a total of 420 TLD measurements. Five patients were evaluated near the location of the mastectomy scar, whereas 9 patients were evaluated throughout the treatment volume. The measured dose at each location was compared with calculations from the treatment planning system. Results: The mean difference and standard error of the mean difference between measurement and calculation for the scar measurements was -1.8% {+-} 0.2% (standard deviation [SD], 4.3%; range, -11.1% to 10.6%). The mean difference and standard error of the mean difference between measurement and calculation for measurements throughout the treatment volume was -3.0% {+-} 0.4% (SD, 4.7%; range, -18.4% to 12.6%). The mean difference and standard error of the mean difference between measurement and calculation for all measurements was -2.1% {+-} 0.2% (standard deviation, 4.5%: range, -18.4% to 12.6%). The mean difference between measured and calculated TLD doses was statistically significant at two standard deviations of the mean, but was not clinically significant (i.e., was <5%). However, 23% of the measured TLD doses differed from the calculated TLD doses by more than 5%. Conclusions: The mean of the measured TLD doses agreed with TomoTherapy calculated TLD doses within our clinical criterion of 5%.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Hybrid functional calculation of electronic and phonon structure of BaSnO{sub 3}

Barium stannate, BaSnO{sub 3} (BSO), with a cubic perovskite structure, has been highlighted as a promising host material for the next generation transparent oxide electrodes. This study examined theoretically the electronic structure and phonon structure of BSO using hybrid density functional theory based on the HSE06 functional. The electronic structure results of BSO were corrected by extending the phonon calculations based on the hybrid density functional. The fundamental thermal properties were also predicted based on a hybrid functional calculation. Overall, a detailed understanding of the electronic structure, phonon modes and phonon dispersion of BSO will provide a theoretical starting-point for engineering applications of this material. - Graphical Abstract: (a) Crystal structure of BaSnO{sub 3}. The center ball is Ba and small (red) ball on edge is oxygen and SnO{sub 6} octahedrons are plotted as polyhedron. (b) Electronic band structure along the high symmetry point in the Brillouin zone using the HSE06 hybrid functional. (c) The phonon dispersion curve calculated using the HSE06 hybrid functional (d) Zone center lowest energy F{sub 1u} phonon mode. Highlights: Black-Right-Pointing-Pointer We report the full hybrid functional calculation of not only the electronic structure but also the phonon structure for BaSnO{sub 3}. Black-Right-Pointing-Pointer The band gap calculation of HSE06 revealed an indirect gap with 2.48 eV. Black-Right-Pointing-Pointer The effective mass at the conduction band minimum and valence band maximum was calculated. Black-Right-Pointing-Pointer In addition, the phonon structure of BSO was calculated using the HSE06 functional. Black-Right-Pointing-Pointer Finally, the heat capacity was calculated and compared with the recent experimental result.

36 MATERIALS SCIENCE↗

Dosimetric comparison of lung stereotactic body radiotherapy treatment plans using averaged computed tomography and end-exhalation computed tomography images: Evaluation of the effect of different dose-calculation algorithms and prescription methods

The purpose of this article is to quantitatively evaluate differences in dose distributions calculated using various computed tomography (CT) datasets, dose-calculation algorithms, and prescription methods in stereotactic body radiotherapy (SBRT) for patients with early-stage lung cancer. Data on 29 patients with early-stage lung cancer treated with SBRT were retrospectively analyzed. Averaged CT (Ave-CT) and expiratory CT (Ex-CT) images were reconstructed for each patient using 4-dimensional CT data. Dose distributions were initially calculated using the Ave-CT images and recalculated (in the same monitor units [MUs]) by employing Ex-CT images with the same beam arrangements. The dose-volume parameters, including D{sub 95}, D{sub 90}, D{sub 50}, and D{sub 2} of the planning target volume (PTV), were compared between the 2 image sets. To explore the influence of dose-calculation algorithms and prescription methods on the differences in dose distributions evident between Ave-CT and Ex-CT images, we calculated dose distributions using the following 3 different algorithms: x-ray Voxel Monte Carlo (XVMC), Acuros XB (AXB), and the anisotropic analytical algorithm (AAA). We also used 2 different dose-prescription methods; the isocenter prescription and the PTV periphery prescription methods. All differences in PTV dose-volume parameters calculated using Ave-CT and Ex-CT data were within 3 percentage points (%pts) employing the isocenter prescription method, and within 1.5%pts using the PTV periphery prescription method, irrespective of which of the 3 algorithms (XVMC, AXB, and AAA) was employed. The frequencies of dose-volume parameters differing by >1%pt when the XVMC and AXB were used were greater than those associated with the use of the AAA, regardless of the dose-prescription method employed. All differences in PTV dose-volume parameters calculated using Ave-CT and Ex-CT data on patients who underwent lung SBRT were within 3%pts, regardless of the dose-calculation algorithm or the dose-prescription method employed.

61 RADIATION PROTECTION AND DOSIMETRY↗

Dose-volume and radiobiological dependence on the calculation grid size in prostate VMAT planning

This study evaluated the effects of dose-volume and radiobiological dependence on the calculation grid size in prostate volumetric-modulated arc therapy (VMAT) planning. Ten patients with prostate cancer were selected for this retrospective treatment planning study. Prostate VMAT plans were created for the patients using the 6 MV photon beam produced by a Varian TrueBEAM linac with the calculation grid size equal to 1, 2, 2.5, 3, 4, and 5 mm. Dose-volume histograms (DVHs) of targets and organs at risk were generated for different grid sizes. We calculated the radiobiological parameters of the tumor control probability (TCP) of clinical target volume (CTV) and planning target volume (PTV), and the normal tissue complication probability (NTCP) of organs at risk (rectal wall, rectum, bladder wall, bladder, left femur, and right femur). The homogeneity, conformity, and gradient indexes of CTV and PTV were calculated for different grid sizes. The TCP of PTV was found decreasing with a rate of 0.06%/mm when the calculation grid size increased from 1 to 5 mm. On the other hand, both NTCPs of rectal wall and rectum were found decreasing with rates of 0.03%/mm and 0.05%/mm, respectively, with an increase of grid size. The homogeneity index of PTV increased with a rate of 0.57/mm of the calculation grid size, whereas the conformity index of PTV decreased with a rate of 0.0075/mm. The gradient index of PTV was found increasing with a rate equal to 0.05/mm. In prostate VMAT planning, variations of dose-volume and radiobiological parameters with calculation grid size on PTV, rectal wall, and rectum were more significant than those of CTV and other organs at risk such as bladder wall, bladder, and femurs. Results in this study are important in the treatment planning quality assurance when the calculation grid size is varied to compromise a shorter dose computing time.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Improved methods for calculating thermodynamic properties of magnetic systems using Wang-Landau density of states

The Wang-Landau method [F. Wang and D. P. Landau, Phys. Rev. E 64, 056101 (2001)] is an efficient way to calculate the density of states (DOS) for magnetic systems, and the DOS can then be used to rapidly calculate the thermodynamic properties of the system. A technique is presented that uses the DOS for a simple Hamiltonian to create a stratified sample of configurations which are then used calculate a warped DOS for more realistic Hamiltonians. This technique is validated for classical models of bcc Fe with exchange interactions of increasing range, but its real value is using the DOS for a model Hamiltonian calculated on a workstation to select the stratified set of configurations whose energies can then be calculated for a density-functional Hamiltonian. The result is an efficient first-principles calculation of thermodynamic properties such as the specific heat and magnetic susceptibility. Another technique uses the sample configurations to calculate the parameters of a model exchange interaction using a least-squares approach. The thermodynamic properties can be subsequently evaluated using traditional Monte Carlo techniques for the model exchange interaction. Finally, a technique that uses the configurations to train a neural network to estimate the configuration energy is also discussed. This technique could potentially be useful in identifying the configurations most important in calculating the warped DOS. VC2011 American Institute of Physics. [doi:10.1063/1.3565413]

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Calculating the binding free energies of charged species based on explicit-solvent simulations employing lattice-sum methods: An accurate correction scheme for electrostatic finite-size effects

The calculation of a protein-ligand binding free energy based on molecular dynamics (MD) simulations generally relies on a thermodynamic cycle in which the ligand is alchemically inserted into the system, both in the solvated protein and free in solution. The corresponding ligand-insertion free energies are typically calculated in nanoscale computational boxes simulated under periodic boundary conditions and considering electrostatic interactions defined by a periodic lattice-sum. This is distinct from the ideal bulk situation of a system of macroscopic size simulated under non-periodic boundary conditions with Coulombic electrostatic interactions. This discrepancy results in finite-size effects, which affect primarily the charging component of the insertion free energy, are dependent on the box size, and can be large when the ligand bears a net charge, especially if the protein is charged as well. This article investigates finite-size effects on calculated charging free energies using as a test case the binding of the ligand 2-amino-5-methylthiazole (net charge +1 e) to a mutant form of yeast cytochrome c peroxidase in water. Considering different charge isoforms of the protein (net charges −5, 0, +3, or +9 e), either in the absence or the presence of neutralizing counter-ions, and sizes of the cubic computational box (edges ranging from 7.42 to 11.02 nm), the potentially large magnitude of finite-size effects on the raw charging free energies (up to 17.1 kJ mol{sup −1}) is demonstrated. Two correction schemes are then proposed to eliminate these effects, a numerical and an analytical one. Both schemes are based on a continuum-electrostatics analysis and require performing Poisson-Boltzmann (PB) calculations on the protein-ligand system. While the numerical scheme requires PB calculations under both non-periodic and periodic boundary conditions, the latter at the box size considered in the MD simulations, the analytical scheme only requires three non-periodic PB calculations for a given system, its dependence on the box size being analytical. The latter scheme also provides insight into the physical origin of the finite-size effects. These two schemes also encompass a correction for discrete solvent effects that persists even in the limit of infinite box sizes. Application of either scheme essentially eliminates the size dependence of the corrected charging free energies (maximal deviation of 1.5 kJ mol{sup −1}). Because it is simple to apply, the analytical correction scheme offers a general solution to the problem of finite-size effects in free-energy calculations involving charged solutes, as encountered in calculations concerning, e.g., protein-ligand binding, biomolecular association, residue mutation, pK{sub a} and redox potential estimation, substrate transformation, solvation, and solvent-solvent partitioning.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Theoretical calculations of rotationally inelastic collisions of He with NaK(A {sup 1}Σ{sup +}): Transfer of population, orientation, and alignment

We have performed extensive calculations to investigate thermal energy, rotationally inelastic collisions of NaK (A{sup 1}Σ{sup +}) with He. We determined a potential energy surface using a multi-reference configuration interaction wave function as implemented by the GAMESS electronic structure code, and we have performed coupled channel scattering calculations using the Arthurs and Dalgarno formalism. We also calculate the Grawert coefficients B{sub λ}(j, j′) for each j → j′ transition. These coefficients are used to determine the probability that orientation and alignment are preserved in collisions taking place in a cell environment. The calculations include all rotational levels with j or j′ between 0 and 50, and total (translational and rotational) energies in the range 0.0002–0.0025 a.u. (∼44–550 cm{sup −1}). The calculated cross sections for transitions with even values of Δj tend to be larger than those for transitions with odd Δj, in agreement with the recent experiments of Wolfe et al. (J. Chem. Phys. 134, 174301 (2011)). The calculations of the energy dependence of the cross sections and the calculations of the fraction of orientation and alignment preserved in collisions also exhibit distinctly different behaviors for odd and even values of Δj. The calculations also indicate that the average fraction of orientation or alignment preserved in a transition becomes larger as j increases. We interpret this behavior using the semiclassical model of Derouard, which also leads to a simple way of visualizing the distribution of the angles between the initial and final angular momentum vectors j and j′. Finally, we compare the exact quantum results for j → j′ transitions with results based on the simpler, energy sudden approximation. That approximation is shown to be quite accurate.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Dirac-Fock-Breit-Gaunt calculations for tungsten hexacarbonyl W(CO){sub 6}

The first all-electron fully relativistic Dirac-Fock-Breit-Gaunt (DFBG), Dirac–Fock (DF), and nonrelativistic (NR) Hartree-Fock (HF) calculations are reported for octahedral (O{sub h}) tungsten hexacarbonyl W(CO){sub 6}. Our DF and NR HF calculations predict atomization energy of 73.76 and 70.33 eV, respectively. The relativistic contribution of ∼3.4 eV to the atomization energy of W(CO){sub 6} is fairly significant. The DF and NR energy for the reaction W + 6CO → W(CO){sub 6} is calculated as −7.90 and −8.86 eV, respectively. The mean bond energy predicted by our NR and DF calculations is 142.5 kJ/mol and 177.5 kJ/mol, respectively, and our predicted DF mean bond energy is in excellent agreement with the experimental value of 179 kJ/mol quoted in the literature. The relativistic effects contribute ∼35 kJ/mol to the mean bond energy and the calculated BSSE is 1.6 kcal/mol, which indicates that the triple zeta basis set used here is fairly good. The mean bond energy and the atomization energy calculated in our DFBG SCF calculations, which include variationally both the relativistic and magnetic Breit effects, is 157.4 kJ/mol and 68.84 eV, respectively. The magnetic Breit effects lead to a decrease of ∼20 kJ/mol and ∼4.9 eV for the mean bond energy and atomization energy, respectively, for W(CO){sub 6}. Our calculated magnetic Breit interaction energy of −9.79 eV for the energy of reaction (ΔE) for W + 6CO → W(CO){sub 6} is lower by ∼1.90 eV as compared to the corresponding DF value (ΔE) and contributes significantly to the ΔE. A detailed discussion is presented of electronic structure, bonding, and molecular energy levels at various levels of theory for W(CO){sub 6}.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Reliable density functional calculations for the electronic structure of thermoelectric material ZnSb

In this paper, we present the results of systematic test calculations for the electronic structure of thermoelectric material ZnSb using a first-principles full-potential all electron computational method. We used a linear combination of atomic orbitals (LACO) formalism, based on density functional theory (DFT). The exchange-correlation interaction potential of the many electron system was described by using a generalized gradient approximation (GGA). We compared the calculated indirect and direct band gaps as well as the effective masses of holes and electrons in ZnSb with experimental measurement results. The calculated indirect band gap of ZnSb is 0.56 eV, which agrees very well with the experimentally measured values of 0.50 eV ~ 0.61 eV. The calculated direct band gap at X point is 0.89 eV. The calculated effective masses of electrons and holes in ZnSb also agree with experimental data. The systematical test calculations as well as the comparisons of the calculated results with experimental measurements show that the obtained electronic structure of ZnSb would be reliable. We did not observe a major deficiency of the first-principles DFT calculation for the electronic structure of ZnSb, using full-potential all electron LACO method. The reported electronic structure of single crystal ZnSb from this work may provide a fundamental knowledge base for further research and applications for this important thermoelectric material.

36 MATERIALS SCIENCE↗

Nonlinear elastic response of strong solids: First-principles calculations of the third-order elastic constants of diamond

Accurate theoretical calculations of the nonlinear elastic response of strong solids (e.g., diamond) constitute a fundamental and important scientific need for understanding the response of such materials and for exploring the potential synthesis and design of novel solids. However, without corresponding experimental data, it is difficult to select between predictions from different theoretical methods. Recently the complete set of third-order elastic constants (TOECs) for diamond was determined experimentally, and the validity of various theoretical approaches to calculate the same may now be assessed. We report on the use of density functional theory (DFT) methods to calculate the six third-order elastic constants of diamond. Two different approaches based on homogeneous deformations were used: (1) an energy-strain fitting approach using a prescribed set of deformations, and (2) a longitudinal stress-strain fitting approach using uniaxial compressive strains along the [100], [110], and [111] directions, together with calculated pressure derivatives of the second-order elastic constants. The latter approach provides a direct comparison to the experimental results. The TOECs calculated using the energy-strain approach differ significantly from the measured TOECs. In contrast, calculations using the longitudinal stress-uniaxial strain approach show good agreement with the measured TOECs and match the experimental values significantly better than the TOECs reported in previous theoretical studies. Lastly, our results on diamond have demonstrated that, with proper analysis procedures, first-principles calculations can indeed be used to accurately calculate the TOECs of strong solids.

36 MATERIALS SCIENCE↗

Multi-step Monte Carlo calculations applied to nuclear reactor instrumentation - source definition and renormalization to physical values

Significant efforts have been made over the last few years in the French Alternative Energies and Atomic Energy Commission (CEA) to adopt multi-step Monte Carlo calculation schemes in the investigation and interpretation of the response of nuclear reactor instrumentation detectors (e.g. miniature ionization chambers - MICs and self-powered neutron or gamma detectors - SPNDs and SPGDs). The first step consists of the calculation of the primary data, i.e. evaluation of the neutron and gamma flux levels and spectra in the environment where the detector is located, using a computational model of the complete nuclear reactor core and its surroundings. These data are subsequently used to define sources for the following calculation steps, in which only a model of the detector under investigation is used. This approach enables calculations with satisfactory statistical uncertainties (of the order of a few %) within regions which are very small in size (the typical volume of which is of the order of 1 mm{sup 3}). The main drawback of a calculation scheme as described above is that perturbation effects on the radiation conditions caused by the detectors themselves are not taken into account. Depending on the detector, the nuclear reactor and the irradiation position, the perturbation in the neutron flux as primary data may reach 10 to 20%. A further issue is whether the model used in the second step calculations yields physically representative results. This is generally not the case, as significant deviations may arise, depending on the source definition. In particular, as presented in the paper, the injudicious use of special options aimed at increasing the computation efficiency (e.g. reflective boundary conditions) may introduce unphysical bias in the calculated flux levels and distortions in the spectral shapes. This paper presents examples of the issues described above related to a case study on the interpretation of the signal from different types of SPNDs, which were recently irradiated in the Jozef Stefan Institute TRIGA Mark II reactor in Ljubljana, Slovenia, and provides recommendations on how they can be overcome. The paper concludes with a discussion on the renormalization of the results from the second step calculations, to obtain accurate physical values. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Optimization of the computational efficiency of a 3D, collapsed cone dose calculation algorithm for brachytherapy

Brachytherapy dose calculations based on point kernel superposition using the collapsed cone method have been shown to accurately model the influence from finite dimensions of the patient and effects from heterogeneities including those of high atomic numbers. The collapsed cone method is for brachytherapy applications most effectively implemented through a successive-scattering approach, in which the dose from once and higher order of scattered photons is calculated separately and in successive scatter order. The calculation speed achievable is directly proportional to the number of directions used for point kernel discretization and to the number of voxels in the volume. In this work we investigate how to best divide the total number of directions between the two steps of successive-scattering dose calculations. Results show that the largest fraction of the total number of directions should be utilized in calculating the first-scatter dose. Also shown is how the number of directions required for keeping discretization artifacts at acceptably low levels decreases significantly in multiple-source configurations, as a result of the dose gradients being less steep than those around single sources. Investigating the number of kernel directions required to keep artifacts low enough within the high dose region of an implant (i.e., for dose levels above approximately 5%-10% of the mean central target dose) reveals similar figures for brachytherapy as for external beam applications, where collapsed cone superposition is clinically used. Also shown is that approximating point kernels with their isotropic average leads to small dose differences at low and intermediate energies, implying that the collapsed cone calculations can be done in a single operation common to all sources of the implant at these energies. The current findings show that collapsed cone calculations can be achieved for brachytherapy with the same efficiency as for external beams. This, combined with recent results on gains in efficiency through implementing the algorithm on graphical card parallel hardware indicates that dose can be calculated with account for heterogeneities and finite dimensions within a few seconds for large voxel arrays and is therefore of interest for practical application to treatment planning.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

An EGSnrc Monte Carlo-calculated database of TG-43 parameters

Monte Carlo methods are used to calculate a complete TG-43 dosimetry parameter data set for 27 low-energy photon emitting brachytherapy sources (18 {sup 125}I and 9 {sup 103}Pd). All Monte Carlo calculations are performed using the EGSnrc user-code BrachyDose. TG-43 dosimetry parameters, including dose rate constants, radial dose functions (with functional fitting parameters), and anisotropy data, are calculated with finer spatial resolution, greater range of distances, and smaller uncertainties than data currently available in the literature for many of these sources. In particular, for most of the seeds, this is the first time that anisotropy data have been tabulated at distances less than 0.5 cm from the source. These calculations employ the state-of-the-art XCOM photon cross sections, and detailed source geometries are modeled using Yegin's multigeometry package. This data set serves as a completely independent verification of the currently available dosimetry parameters calculated using other Monte Carlo codes, including MCNP and PTRAN. This report also describes the Carleton Laboratory for Radiotherapy Physics TG-43 Parameter Database, a publicly accessible web site (at http://www.physics.carleton.ca/clrp/seed{sub d}atabase/) through which all of the data calculated for this study can be accessed. Also available on the web site are descriptions of the methods and Monte Carlo models used in this study and comparisons of data calculated in this study with data calculated by other authors.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dose calculation with respiration-averaged CT processed from cine CT without a respiratory surrogate

Dose calculation for thoracic radiotherapy is commonly performed on a free-breathing helical CT despite artifacts caused by respiratory motion. Four-dimensional computed tomography (4D-CT) is one method to incorporate motion information into the treatment planning process. Some centers now use the respiration-averaged CT (RACT), the pixel-by-pixel average of the ten phases of 4D-CT, for dose calculation. This method, while sparing the tedious task of 4D dose calculation, still requires 4D-CT technology. The authors have recently developed a means to reconstruct RACT directly from unsorted cine CT data from which 4D-CT is formed, bypassing the need for a respiratory surrogate. Using RACT from cine CT for dose calculation may be a means to incorporate motion information into dose calculation without performing 4D-CT. The purpose of this study was to determine if RACT from cine CT can be substituted for RACT from 4D-CT for the purposes of dose calculation, and if increasing the cine duration can decrease differences between the dose distributions. Cine CT data and corresponding 4D-CT simulations for 23 patients with at least two breathing cycles per cine duration were retrieved. RACT was generated four ways: First from ten phases of 4D-CT, second, from 1 breathing cycle of images, third, from 1.5 breathing cycles of images, and fourth, from 2 breathing cycles of images. The clinical treatment plan was transferred to each RACT and dose was recalculated. Dose planes were exported at orthogonal planes through the isocenter (coronal, sagittal, and transverse orientations). The resulting dose distributions were compared using the gamma ({gamma}) index within the planning target volume (PTV). Failure criteria were set to 2%/1 mm. A follow-up study with 50 additional lung cancer patients was performed to increase sample size. The same dose recalculation and analysis was performed. In the primary patient group, 22 of 23 patients had 100% of points within the PTV pass {gamma} criteria. The average maximum and mean {gamma} indices were very low (well below 1), indicating good agreement between dose distributions. Increasing the cine duration generally increased the dose agreement. In the follow-up study, 49 of 50 patients had 100% of points within the PTV pass the {gamma} criteria. The average maximum and mean {gamma} indices were again well below 1, indicating good agreement. Dose calculation on RACT from cine CT is negligibly different from dose calculation on RACT from 4D-CT. Differences can be decreased further by increasing the cine duration of the cine CT scan.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A generalized 2D pencil beam scaling algorithm for proton dose calculation in heterogeneous slab geometries

Purpose: Pencil beam algorithms are commonly used for proton therapy dose calculations. Szymanowski and Oelfke ['Two-dimensional pencil beam scaling: An improved proton dose algorithm for heterogeneous media,' Phys. Med. Biol. 47, 3313-3330 (2002)] developed a two-dimensional (2D) scaling algorithm which accurately models the radial pencil beam width as a function of depth in heterogeneous slab geometries using a scaled expression for the radial kernel width in water as a function of depth and kinetic energy. However, an assumption made in the derivation of the technique limits its range of validity to cases where the input expression for the radial kernel width in water is derived from a local scattering power model. The goal of this work is to derive a generalized form of 2D pencil beam scaling that is independent of the scattering power model and appropriate for use with any expression for the radial kernel width in water as a function of depth. Methods: Using Fermi-Eyges transport theory, the authors derive an expression for the radial pencil beam width in heterogeneous slab geometries which is independent of the proton scattering power and related quantities. The authors then perform test calculations in homogeneous and heterogeneous slab phantoms using both the original 2D scaling model and the new model with expressions for the radial kernel width in water computed from both local and nonlocal scattering power models, as well as a nonlocal parameterization of Moliere scattering theory. In addition to kernel width calculations, dose calculations are also performed for a narrow Gaussian proton beam. Results: Pencil beam width calculations indicate that both 2D scaling formalisms perform well when the radial kernel width in water is derived from a local scattering power model. Computing the radial kernel width from a nonlocal scattering model results in the local 2D scaling formula under-predicting the pencil beam width by as much as 1.4 mm (21%) at the depth of the Bragg peak for a 220 MeV proton beam in homogeneous water. This translates into a 32% dose discrepancy for a 5 mm Gaussian proton beam. Similar trends were observed for calculations made in heterogeneous slab phantoms where it was also noted that errors tend to increase with greater beam penetration. The generalized 2D scaling model performs well in all situations, with a maximum dose error of 0.3% at the Bragg peak in a heterogeneous phantom containing 3 cm of hard bone. Conclusions: The authors have derived a generalized form of 2D pencil beam scaling which is independent of the proton scattering power model and robust to the functional form of the radial kernel width in water used for the calculations. Sample calculations made with this model show excellent agreement with expected values in both homogeneous water and heterogeneous phantoms.

61 RADIATION PROTECTION AND DOSIMETRY↗

Evaluation of a semiautomated lung mass calculation technique for internal dosimetry applications

Purpose: The authors sought to evaluate a simple, semiautomated lung mass estimation method using computed tomography (CT) scans obtained using a variety of acquisition techniques and reconstruction parameters for mass correction of medical internal radiation dose-based internal radionuclide radiation absorbed dose estimates.Methods: CT scans of 27 patients with lung cancer undergoing stereotactic body radiation therapy treatment planning with PET/CT were analyzed retrospectively. For each patient, free-breathing (FB) and respiratory-gated 4DCT scans were acquired. The 4DCT scans were sorted into ten respiratory phases, representing one complete respiratory cycle. An average CT reconstruction was derived from the ten-phase reconstructions. Mid expiration breath-hold CT scans were acquired in the same session for many patients. Deep inspiration breath-hold diagnostic CT scans of many of the patients were obtained from different scanning sessions at similar time points to evaluate the effect of contrast administration and maximum inspiration breath-hold. Lung mass estimates were obtained using all CT scan types, and intercomparisons made to assess lung mass variation according to scan type. Lung mass estimates using the FB CT scans from PET/CT examinations of another group of ten male and ten female patients who were 21–30 years old and did not have lung disease were calculated and compared with reference lung mass values. To evaluate the effect of varying CT acquisition and reconstruction parameters on lung mass estimation, an anthropomorphic chest phantom was scanned and reconstructed with different CT parameters. CT images of the lungs were segmented using the OsiriX MD software program with a seed point of about −850 HU and an interval of 1000. Lung volume, and mean lung, tissue, and air HUs were recorded for each scan. Lung mass was calculated by assuming each voxel was a linear combination of only air and tissue. The specific gravity of lung volume was calculated using the formula (lung HU − air HU)/(tissue HU − air HU), and mass = specific gravity × total volume × 1.04 g/cm{sup 3}.Results: The range of calculated lung masses was 0.51–1.29 kg. The average male and female lung masses during FB CT were 0.80 and 0.71 kg, respectively. The calculated lung mass varied across the respiratory cycle but changed to a lesser degree than did lung volume measurements (7.3% versus 15.4%). Lung masses calculated using deep inspiration breath-hold and average CT were significantly larger (p < 0.05) than were some masses calculated using respiratory-phase and FB CT. Increased voxel size and smooth reconstruction kernels led to high lung mass estimates owing to partial volume effects.Conclusions: Organ mass correction is an important component of patient-specific internal radionuclide dosimetry. Lung mass calculation necessitates scan-based density correction to account for volume changes owing to respiration. The range of lung masses in the authors’ patient population represents lung doses for the same absorbed energy differing from 25% below to 64% above the dose found using reference phantom organ masses. With proper management of acquisition parameters and selection of FB or midexpiration breath hold scans, lung mass estimates with about 10% population precision may be achieved.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

TH-A-19A-09: Towards Sub-Second Proton Dose Calculation On GPU

Purpose: To achieve sub-second dose calculation for clinically relevant proton therapy treatment plans. Rapid dose calculation is a key component of adaptive radiotherapy, necessary to take advantage of the better dose conformity offered by hadron therapy. Methods: To speed up proton dose calculation, the pencil beam algorithm (PBA; clinical standard) was parallelised and implemented to run on a graphics processing unit (GPU). The implementation constitutes the first PBA to run all steps on GPU, and each part of the algorithm was carefully adapted for efficiency. Monte Carlo (MC) simulations obtained using Fluka of individual beams of energies representative of the clinical range impinging on simple geometries were used to tune the PBA. For benchmarking, a typical skull base case with a spot scanning plan consisting of a total of 8872 spots divided between two beam directions of 49 energy layers each was provided by CNAO (Pavia, Italy). The calculations were carried out on an Nvidia Geforce GTX680 desktop GPU with 1536 cores running at 1006 MHz. Results: The PBA reproduced within ±3% of maximum dose results obtained from MC simulations for a range of pencil beams impinging on a water tank. Additional analysis of more complex slab geometries is currently under way to fine-tune the algorithm. Full calculation of the clinical test case took 0.9 seconds in total, with the majority of the time spent in the kernel superposition step. Conclusion: The PBA lends itself well to implementation on many-core systems such as GPUs. Using the presented implementation and current hardware, sub-second dose calculation for a clinical proton therapy plan was achieved, opening the door for adaptive treatment. The successful parallelisation of all steps of the calculation indicates that further speedups can be expected with new hardware, brightening the prospects for real-time dose calculation. This work was funded by ENTERVISION, European Commission FP7 grant 264552.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗