Report of the Third Biomedical Confidence Building Exercise
Abstract not provided
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Abstract not provided
Explore the source record for details and available documents.
Explore the source record for details and available documents.
For several, widespread dermatologic disorders such as psoriasis and Bowman’s disease, no cure currently exists but the irradiation of the affected tissue at specific wavelengths in the ultraviolet (UV) is the only known therapeutic treatment that drives the disorder into remission. Furthermore, currently available treatments based on lasers are expensive and access is severely restricted for the millions of patients (in the U.S. alone) who suffer from these diseases. Recently, however, microcavity plasma technology developed at Eden Park Illumination (EPI) and the University of Illinois has resulted in flat (or curved) lamps that are thin and capable of emitting UV at discrete wavelengths. EPI has, for example, commercialized lamps as large as 4” × 4” (100 cm 2 ) in emitting area that generate more than 10 W of average power at 172 nm. These results are well beyond the performance available in the past from lamps emitting in the deep-ultraviolet, and it appears that this technology can be readily modified to operate at other UV wavelengths.
Abstract not provided.
Explore the source record for details and available documents.
Polymeric nanoparticles (PNPs) are solid particles that contain macromolecular polymers ranging in size from 1-1000 nm. They have a wide variety of structures that are determined by their identity as either natural biopolymers, synthetic polymers or a combination of both. In the design of PNPs, the polymeric system, size, internal structure, additional molecules, and synthetic pathway can be engineered, allowing for a multitude of properties including differing responses to physiological environments and the incorporation of a drug. The easily accessible fine tuning of PNPs allows for a multitude of applications in medicine. PNPs allow for increased pharmacokinetics, efficacy, safety, and targeting strength when utilized as carriers for drugs. Currently there are a wide range of PNPs approved by the Food and Drug Administration for use in clinical settings and many more being investigated in clinical studies. There is also research that is being conducted for the usage of PNPs in controlled drug delivery systems and as carriers through the blood brain barrier to aid in treating neurological diseases.
We compare the performance of hand-tuned CUDA implementations of bilateral and anisotropic diffusion filters for denoising 3D MRI datasets. Our tests sweep comparable parameters for the two filters and measure total runtime, memory bandwidth, computational throughput, and mean squared errors relative to a noiseless reference dataset.
Long-term packaging of miniaturized, flexible implantable medical devices is essential for the next generation of medical devices. Polymer materials that are biocompatible and flexible have attracted extensive interest for the packaging of implantable medical devices, however realizing these devices with long-term hermeticity up to several years remains a great challenge. Here, polyimide (PI) based hermetic encapsulation was greatly improved by atomic layer deposition (ALD) of a nanoscale-thin, biocompatible sandwich stack of HfO 2 /Al 2 O 3 /HfO 2 (ALD-3) between two polyimide layers. A thin copper film covered with a PI/ALD-3/PI barrier maintained excellent electrochemical performance over 1028 days (2.8 years) during acceleration tests at 60 °C in phosphate buffered saline solution (PBS). This stability is equivalent to approximately 14 years at 37 °C. The coatings were monitored in situ through electrochemical impedance spectroscopy (EIS), were inspected by microscope, and were further analyzed using equivalent circuit modeling. The failure mode of ALD Al 2 O 3 , ALD-3, and PI soaking in PBS is discussed. Encapsulation using ultrathin ALD-3 combined with PI for the packaging of implantable medical devices is robust at the acceleration temperature condition for more than 2.8 years, showing that it has great potential as reliable packaging for long-term implantable devices.
Here, we report on the fabrication of desired magneto-photonic devices by a low one-photon absorption (LOPA) direct laser writing (DLW) technique on a photocurable nanocomposite consisting of magnetite ( Fe 3 O 4 ) nanoparticles and a commercial SU-8 photoresist. The magnetic nanocomposite was synthesized by mixing Fe 3 O 4 nanoparticles with different kinds of SU-8 photoresists. We demonstrated that the degree of dispersion of Fe 3 O 4 nanoparticles in the nanocomposite depended on the concentration of Fe 3 O 4 nanoparticles, the viscosity of SU-8 resist, and the mixing time. By tuning these parameters, the most homogeneous magnetic nanocomposite was obtained with a concentration of about 2 wt % of Fe 3 O 4 nanoparticles in SU-8 2005 photoresist for the mixing time of 20 days. The LOPA-based DLW technique was employed to fabricate on demand various magneto-photonic submicrometer structures, which are similar to those obtained without Fe 3 O 4 nanoparticles. The magneto-photonic 2D and 3D structures with sizes as small as 150 nm were created. Finally, we demonstrated the strong magnetic field responses of the magneto-photonic nanostructures and their use as micro-actuators when immersed in a liquid solution. View Full-Text
Explore the source record for details and available documents.
Applications of aerospace medical research to neurophysiological rehabilitation
Computer programming of heart-rate patterns including base heart rate and respiratory and nonrespiratory heart-rate reflex activity
Gemini ground station pulse code modulation display systems which make biochemical and environmental parameters available in binary codes
This report is the result of a study conducted by Republic Aviation Corporation in conjunction with Spacelabs, Inc.,in a team effort in which Republic Aviation Corporation was prime contractor. In order to determine the realistic engineering design requirements associated with the medical and human factors problems of a manned space station, an interdisciplinary team of personnel from the Research and Space Divisions was organized. This team included engineers, physicians, physiologists, psychologists, and physicists. Recognizing that the value of the study is dependent upon medical judgments as well as more quantifiable factors (such as design parameters) a group of highly qualified medical consultants participated in working sessions to determine which medical measurements are required to meet the objectives of the study. In addition, various Life Sciences personnel from NASA (Headquarters, Langley, MSC) participated in monthly review sessions. The organization, team members, consultants, and some of the part-time contributors are shown in Figure 1. This final report embodies contributions from all of these participants.
Semiconductor radiation dosimeter in the form of a slender probe is easily inserted into body tissue. The probe has a signal-to-noise ratio that is acceptable to recording equipment and provides realistic measurements of the spatial and energy distributions of radiant electrons and protons.
Physiological responses and work capacity studies conducted during cosmonaut training and space flights
Levy hypoxia test and associated arterial oxygen desaturation and increased cardiac output