Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “beam diagnostics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

Feasibility study of a high spatial and time resolution beam emission spectroscopy diagnostic for localized density fluctuation measurements in Lithium Tokamak eXperiment-β (LTX-β)

Trapped electron mode (TEM) is the main source of turbulence predicted for the unique operation regime of a flat temperature profile under low-recycling conditions in the LTX-β tokamak, while ion temperature gradient driven turbulence may also occur with gas fueling from the edge. To investigate mainly TEM scale density fluctuations, a high spatial and time resolution 2D beam emission spectroscopy (BES) diagnostic is being developed. Apart from spatially localized density turbulence measurement, BES can provide turbulence flow and flow shear dynamics. This BES system will be realized using an avalanche photodiode-based camera and narrow band interference filter. The system can acquire data at 2 MHz. Simulations with the Simulation of Spectra (SOS) code indicate that a high signal to noise ratio can be achieved with the proposed system. This will enable sampling the density fluctuations at this high time resolution. Finally, the design considerations and system optimization using the SOS code are presented.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

LASER APPLICATIONS: H- BEAM PHOTO-DETACHMENT AND PUSH BUTTON DIAGNOSTICS

The laser based nonintrusive H- beam diagnostics and laser assisted H- beam stripping technologies have been developed at the Spallation Neutron Source (SNS). This paper reviews the present status of the SNS laser based diagnostics and the recent R&D progress on the fiber transmission of laser pulses and power enhancement optical cavity which will be used in diagnostics and laser stripping.

diagnostics↗

A compact, high resolution energy, and emittance diagnostic for electron beams using active plasma lenses

High-resolution (sub-%), single-shot energy distribution, and emittance measurements of GeV-class electron beams generated by laser plasma accelerators (LPAs) have been enabled through the use of an active plasma lens combined with relatively short dipole magnets. This setup, with only 60 cm between the LPA source and the final diagnostic screen, was facilitated through the use of a replenishable ∼20–40 nm thick liquid crystal plasma mirror to separate remnant laser radiation from the electron beam without emittance degradation. As LPAs capable of generating GeV-class electron beams at cm-scale distances become increasingly ubiquitous, there is a need to supplement these compact accelerators with equally compact diagnostics.

Barber, S. K. (ORCID:0000000172518755)↗

Longitudinal Diagnostics for Short Electron Beam Bunches

Single-pass free electron lasers require high peak currents from ultra-short electron bunches to reach saturation and an accurate measurement of bunch length and longitudinal bunch profile is necessary to control the bunch compression process from low to high beam energy. The various state-of-the-art diagnostics methods from ps to fs time scales using coherent radiation detection, RF deflection, and other techniques are presented. The use of linear accelerators as drivers for free electron lasers (FEL) and the advent of single-pass (SASE) FELs has driven the development of a wide range of diagnostic techniques for measuring the length and longitudinal distribution of short and ultra-short electron bunches. For SASE FELs the radiation power and the length of the undulator needed to achieve saturation depend strongly on the charge density of the electron beam. In the case of X-ray FELs, this requires the accelerator to produce ultra-high brightness beams with micron size transverse normalized emittances and peak currents of several kA through several stages of magnetic bunch compression. Different longitudinal diagnostics are employed to measure the peak current and bunch profile along these stages. The measurement techniques can be distinguished into different classes. Coherent methods detect the light emitted from the beam by some coherent radiation process (spectroscopic measurement), or directly measure the Coulomb field traveling with the beam (electro-optic). Phase space manipulation techniques map the time coordinate onto a transverse dimension and then use conventional transverse beam diagnostics (transverse deflector, rf zero-phasing). Further methods measure the profile or duration of an incoherent light pulse emitted by the bunch at wavelengths much shorted than the bunch length (streak camera, fluctuation technique) or modulate the electron beam at an optical wavelength and then generate a narrow bandwidth radiation pulse with the longitudinal profile of the beam mapped onto (optical replicator). The operational needs for bunch length measurements to have fast acquisitions, to be used in feedback systems, to distinguish pulse to pulse changes and to be nondestructive or parasitically have resulted into developing many of the diagnostics into single-shot techniques and in the following the main discussion will emphasize them.

43 PARTICLE ACCELERATORS↗

Nondestructive diagnostics of charged particle beams in accelerators

The basic techniques for nondestructive diagnostics and detection of losses of charged particle beams used in accelerator engineering are reviewed. The data provided may help choose the systems for diagnostics and detection of losses of beams and give a qualitative picture of the operation principles of such devices. Quantitative characteristics that define the limits of applicability of each diagnostic technique are outlined.

43 PARTICLE ACCELERATORS↗

Aligning the Thomson scattering and charge exchange recombination diagnostics using neutral beam emission at DIII-D

This work addresses discrepancies in the alignment of the H-mode pedestal profiles of the electron and ion properties in the DIII-D tokamak as measured by Thomson Scattering (TS) and Charge Exchange Recombination Spectroscopy (CER) diagnostics. While the alignment of these profiles is key for accurate studies of tokamak physics and plasma confinement, misalignments can occur due to inaccuracies, such as in magnetic equilibrium reconstructions required to map measurements in different poloidal and toroidal locations. Both FIDASIM, an established simulation package, and a simplified collisional radiative model are used to simulate neutral beam state densities and neutral beam emission. Simulated neutral beam emissions are calculated based on shifted TS profiles and compared to beam emission measurements from the Main Ion CER system to determine the best shift for aligning TS with CER. This analysis is performed on various DIII-D discharges.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Overview of Beam Instrumentation and Diagnostics for the NSLS-II Project

A new, ultra-bright 3rd generation light source, the NSLS-II Project, is planned to be built at Brookhaven National Laboratory. The light source being developed will have unprecedently small beam horizontal emittance and will provide the radiation sources with a brightness of 3 x 10{sup 21} photons/sec/0.1%BW/mm{sup 2}/mrad{sup 2}. In this paper we present the detailed specifications and a comprehensive description of the planned beam instrumentation system and the first results of the ongoing instrumentation R&D activities on beyond state-of-the-art subsystems.

43 PARTICLE ACCELERATORS↗

Evaluation of Temporal Diagnostic Techniques for Two-Bunch Facet Beam

Three temporal diagnostic techniques are considered for use in the FACET facility at SLAC, which will incorporate a unique two-bunch beam for plasma wakefield acceleration experiments. The results of these experiments will depend strongly on the the inter-bunch spacing as well as the longitudinal profiles of the two bunches. A reliable, singleshot, high resolution measurement of the beam's temporal profile is necessary to fully quantify the physical mechanisms underlying the beam driven plasma wakefield acceleration. In this study we show that a transverse deflecting cavity is the diagnostic which best meets our criteria. Based on our laboratory testing, numerical calculations, and simulations of the three single-shot temporal diagnostic devices, the X-band TCAV system is the best candidate for resolving FACET's two-bunch beam, with an estimated resolution of 7 {micro}m. Both the S-band TCAV system and the EO system could resolve the peak-to-peak separation of the two bunches in the FACET beam with estimated resolutions of 25 {micro}m and 30 {micro}m, respectively, but would be unable to resolve the temporal profiles of the individual bunches themselves. Because the TCAV signal is more easily interpreted and because the reliability of the EO system is less well known, however, the S-band TCAV system would be the next preferred option after the X-band TCAV system. The Fesca-200 streak camera, though simple, compact, and reliable, is unable to achieve a resolution that would be of use to FACET.

43 PARTICLE ACCELERATORS↗

An Electron-Beam Ion-Neutralization Diagnostic for the Scorpius Radiography Accelerator

Electron beam spilling onto the beam pipe can produce positive ions that are accelerated inward into the beam body by its space charge. These ions partially neutralize the space charge, thereby causing the beam to be mismatched to the magnetic fields used for transport. A diagnostic of neutralization effects has been used on present accelerators, and in this note the feasibility of its use on a future accelerator is assessed.

43 PARTICLE ACCELERATORS↗

Ion source for neutral beam injection meant for plasma and magnetic field diagnostics

At the Lawrence Berkeley National Laboratory a diagnostic neutral beam injection system for measuring plasma parameters, flow velocity, and local magnetic field is being developed. The system is designed to have a 90% proton fraction and small divergence with beam current at 5-6 A and a pulse length of {approx}1 s occurring once every 1-2 min. The ion source needs to generate uniform plasma over a large (8x5 cm{sup 2}) extraction area. For this application, we have compared rf driven multicusp ion sources operating with either an external or an internal antenna in similar ion source geometry. The ion beam will be made of an array of six sheet-shaped beamlets. The design is optimized using computer simulation programs.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

“Metallic burn paper” used for in situ characterization of laser beam properties

In situ ablation of thin metal films on fused silica substrates by picosecond class lasers was investigated in this paper as a method of characterizing the beam at the sample plane. The technique involved plotting the areas enclosed by constant fluence contours identified in optical microscope images of the ablation sites versus the logs of the pulse energies. Inconel films on commercially available neutral density filters as well as magnetron sputtered gold films were used. It was also shown that this technique could be used to calibrate real-time beam profile diagnostics against the beam at the sample plane. Finally, the contours were shown to correspond to the boundary where part or all of the film was ablated.

42 ENGINEERING↗

Thermionic noise measurements for on-line dispenser cathode diagnostics for linear beam microwave tubes

A test stand has been set up to measure the current fluctuation noise properties of B- and M-type dispenser cathodes in a typical TWT gun structure. Noise techniques were used to determine the work function distribution on the cathode surfaces. Significant differences between the B and M types and significant changes in the work function distribution during activation and life are found. In turn, knowledge of the expected work function can be used to accurately determine the cathode-operating temperatures in a TWT structure. Noise measurements also demonstrate more sensitivity to space charge effects than the Miram method. Full automation of the measurements and computations is now required to speed up data acquisition and reduction. The complete set of equations for the space charge limited diode were programmed so that given four of the five measurable variables (J, J sub O, T, D, and V) the fifth could be computed. Using this program, we estimated that an rms fluctuation in the diode spacing d in the frequency range of 145 Hz about 20 kHz of only about 10 to the -5 power A would account for the observed noise in a space charge limited diode with 1 mm spacing.

Holland, C.↗

DIAGNOSTIC TOOLS FOR BEAM HALO INVESTIGATION IN SNS LINAC

Uncontrolled beam loss is a major concern in the operation of a high intensity hadron linac. A low density cloud of particles with large oscillation amplitudes, so called halo, can form around the dense regular beam core. This halo can be a direct or indirect cause of beam loss. There is experimental evidence of halo growing in the SNS linac and limiting the further reduction of beam loss. A set of tools is being developed for detecting of the halo and investigating its origin and dynamics. The set includes high resolution emittance measurements in the injector, laser based emittance measurements at 1 GeV, and high resolution profile measurements along the linac. We will present our experience with useful measurement techniques and data analysis algorithms.

Aleksandrov, Alexander V↗