Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “arms control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

Effect of Long-Duration Spaceflight on Postural Control During Self-Generated Perturbations

This report is the first systematic evaluation of the effects of prolonged weightlessness on the bipedal postural control processes during self-generated perturbations produced by voluntary upper limb movements. Spaceflight impacts humans in a variety of ways, one of which is compromised postflight postural control. We examined the neuromuscular activation characteristics and center of pressure motion (COP) associated with arm movement of eight subjects who experienced long duration spaceflight (3-6 months) aboard the Mir space station. Surface electromyography (EMG), arm acceleration, and COP motion were collected while astronauts performed rapid unilateral shoulder flexions prior to and after spaceflight. Subjects displayed compromised postural control after flight as evidenced by modified peak-to-peak COP anterior-posterior and medio-lateral motion and COP pathlength relative to preflight values. These changes were associated with disrupted neuromuscular activation characteristics, particularly after the completion of arm acceleration (i.e. when subjects were attempting to maintain their upright posture). These findings suggest that although the subjects were able to assemble coordination modes that enabled them to generate rapid arm movements, the subtle control necessary to maintain bipedal equilibrium evident in their preflight performance is compromised after long duration spaceflight.

Layne, Charles S.↗

Robotic Surgery

The Automated Endoscopic System for Optimal Positioning, or AESOP, was developed by Computer Motion, Inc. under a SBIR contract from the Jet Propulsion Lab. AESOP is a robotic endoscopic positioning system used to control the motion of a camera during endoscopic surgery. The camera, which is mounted at the end of a robotic arm, previously had to be held in place by the surgical staff. With AESOP the robotic arm can make more precise and consistent movements. AESOP is also voice controlled by the surgeon. It is hoped that this technology can be used in space repair missions which require precision beyond human dexterity. A new generation of the same technology entitled the ZEUS Robotic Surgical System can make endoscopic procedures even more successful. ZEUS allows the surgeon control various instruments in its robotic arms, allowing for the precision the procedure requires.

Source record↗

An Air Revitalization Model (ARM) for Regenerative Life Support Systems (RLSS)

The primary objective of the air revitalization model (ARM) is to determine the minimum buffer capacities that would be necessary for long duration space missions. Several observations are supported by the current configuration sizes: the baseline values for each gas and the day to day or month to month fluctuations that are allowed. The baseline values depend on the minimum safety tolerances and the quantities of life support consumables necessary to survive the worst case scenarios within those tolerances. Most, it not all, of these quantities can easily be determined by ARM once these tolerances are set. The day to day fluctuations also require a command decision. It is already apparent from the current configuration of ARM that the tighter these fluctuations are controlled, the more energy used, the more nonregenerable hydrazine consumed, and the larger the required capacities for the various gas generators. All of these relationships could clearly be quantified by one operational ARM.

Hart, Maxwell M.↗

Magnetically Suspended Linear Pulse Motor for Semiconductor Wafer Transfer in Vacuum Chamber

This paper describes a magnetically suspended linear pulse motor for a semiconductor wafer transfer robot in a vacuum chamber. The motor can drive a wafer transfer arm horizontally without mechanical contact. In the construction of the magnetic suspension system, four pairs of linear magnetic bearings for the lift control are used for the guidance control as well. This approach allows us to make the whole motor compact in size and light in weight. The tested motor consists of a double-sided stator and a transfer arm with a width of 50 mm and a total length of 700 mm. The arm, like a ladder in shape, is designed as the floating element with a tooth width of 4 mm (a tooth pitch of 8 mm). The mover mass is limited to about 1.6 kg by adopting such an arm structure, and the ratio of thrust to mover mass reaches to 3.2 N/kg under a broad air gap (1 mm) between the stator teeth and the mover teeth. The performance testing was carried out with a transfer distance less than 450 mm and a transfer speed less than 560 mm/s. The attitude of the arm was well controlled by the linear magnetic bearings with a combined use, and consequently the repeatability on the positioning of the arm reached to about 2 micron. In addition, the positioning accuracy was improved up to about 30 micron through a compensation of the 128-step wave current which was used for the micro-step drive with a step increment of 62.5 micron.

Moriyama, Shin-Ichi↗

An 8-DOF dual-arm system for advanced teleoperation performance experiments

This paper describes the electro-mechanical and control features of an 8-DOF manipulator manufactured by AAI Corporation and installed at the Jet Propulsion Lab. (JPL) in a dual-arm setting. The 8-DOF arm incorporates a variety of features not found in other lab or industrial manipulators. Some of the unique features are: 8-DOF revolute configuration with no lateral offsets at joint axes; 1 to 5 payload to weight ratio with 20 kg (44 lb) payload at a 1.75 m (68.5 in.) reach; joint position measurement with dual relative encoders and potentiometer; infinite roll of joint 8 with electrical and fiber optic slip rings; internal fiber optic link of 'smart' end effectors; four-axis wrist; graphite epoxy links; high link and joint stiffness; use of an upgraded JPL Universal Motor Controller (UMC) capable of driving up to 16 joints. The 8-DOF arm is equipped with a 'smart' end effector which incorporates a 6-DOF forcemoment sensor at the end effector base and grasp force sensors at the base of the parallel jaws. The 8-DOF arm is interfaced to a 6 DOF force reflecting hand controller. The same system is duplicated for and installed at NASA-Langley.

Bejczy, Antal K.↗

Human-like Compliance for Dexterous Robot Hands

This paper describes the Active Electromechanical Compliance (AEC) system that was developed for the Jau-JPL anthropomorphic robot. The AEC system imitates the functionality of the human muscle's secondary function, which is to control the joint's stiffness: AEC is implemented through servo controlling the joint drive train's stiffness. The control strategy, controlling compliant joints in teleoperation, is described. It enables automatic hybrid position and force control through utilizing sensory feedback from joint and compliance sensors. This compliant control strategy is adaptable for autonomous robot control as well. Active compliance enables dual arm manipulations, human-like soft grasping by the robot hand, and opens the way to many new robotics applications.

Compliant Control↗

Space Station/Orbiter berthing dynamics during an assembly flight

A large-angle, multi-body, dynamic modeling capability was developed to help validate numerical simulations of the dynamic motion and control forces which occur while berthing Space Station Freedom to the Shuttle Orbiter during early assembly flights. The paper describes the dynamics and control of the station, the attached Shuttle Remote Manipulator System, and the Orbiter during a maneuver from a gravity-gradient attitude to a torque equilibrium attitude using the station reaction control jets. The influence of the elastic behavior of the station and of the remote manipulator system on the attitude control of the station/Orbiter system during the maneuver is investigated. The flexibility of the station and the arm had only a minor influence on the attitude control of the system during the maneuver.

Cooper, Paul A.↗

Impedance hand controllers for increasing efficiency in teleoperations

An impedance hand controller with direct force feedback is examined as an alternative to bilateral force reflection in teleoperations involving force contact. Experimentation revealed an operator preference for direct force feedback which provided a better feel of contact with the environment. The advantages of variable arm impedance were also made clear in tracking tests where subjects preferred the larger hand controller inertias made possible by the acceleration feedback loop in the master arm. The ability to decouple the hand controller impedance from the slave arm dynamics is expected to be even more significant when the inertial properties of various payloads in the slave arm are considered.

Carignan, Craig↗

Impedance hand controllers for increasing efficiency in teleoperations

An impedance hand controller with direct force feedback is examined as an alternative to bilateral force reflection in teleoperations involving force contact. Experimentation revealed an operator preference for direct force feedback which provided a better feel of contact with the environment. The advantages of variable arm impedance were also made clear in tracking tests where subjects preferred the larger hand controller inertias made possible by the acceleration feedback loop in the master arm. The ability to decouple the hand controller impedance from the slave arm dynamics is expected to be even more significant when the inertial properties of various payloads in the slave arm are considered.

Carignan, C.↗

Configuration control of redundant manipulators - Theory and implementation

A simple approach for controlling the manipulator configuration over the entire motion is presented, based on augmentation of the manipulator forward kinematics. User-defined kinematic functions and the end-effector Cartesian coordinates are combined to form a set of task-related configuration variables as generalized coordinates for the manipulator. A task-based adaptive scheme is then utilized to control the configuration variables and achieve tracking of the desired reference trajectories. This achieves the desired end-effector motion while utilizing redundancy to achieve any additional task. Simulation results for a direct-drive two-link arm are given to illustrate the proposed control scheme. The scheme has also been implemented for real-time control of three links of a PUMA 560 industrial robot. The simulation and experimental results validate the configuration control scheme and demonstrate its capabilities for performing various realistic tasks.

Seraji, Homayoun↗

Thermal Nondestructive Evaluation Report: Inspection of the Refurbished Manipulator Arm System in the Manipulator Development Facility at Johnson Space Center 10-12 January 2001

On 4 December 2002, a failure of the Refurbished Manipulator Arm System (RMAS) occurred in the Manipulator Development Facility (MDF) at Johnson Space Center. When the Test Director commanded a should pitch maneuver to lift the arm from its payload bay pedestal, the yaw controls failed. This, coupled with a gravitational forces (due to the angle of the shoulder joint with respect to vertical), resulted in uncontrolled arm motion. The shoulder yaw joint moved approximately 20 degrees, causing the extended arm to strike and severely damage the port side MDF catwalk handrails. The arm motion stopped after impact with the handrails. On 10-12 January 2001, inspections were performed on the port face of the lower and upper arms of the RMAS using a infrared thermography developed at Langley Research Center. This paper presents the results of those nondestructive inspections and provides a complete description of the anomalies found and their locations.

Cramer, K. Elliott↗

Unified Approach To Control Of Motions Of Mobile Robots

Improved computationally efficient scheme developed for on-line coordinated control of both manipulation and mobility of robots that include manipulator arms mounted on mobile bases. Present scheme similar to one described in "Coordinated Control of Mobile Robotic Manipulators" (NPO-19109). Both schemes based on configuration-control formalism. Present one incorporates explicit distinction between holonomic and nonholonomic constraints. Several other prior articles in NASA Tech Briefs discussed aspects of configuration-control formalism. These include "Increasing the Dexterity of Redundant Robots" (NPO-17801), "Redundant Robot Can Avoid Obstacles" (NPO-17852), "Configuration-Control Scheme Copes with Singularities" (NPO-18556), "More Uses for Configuration Control of Robots" (NPO-18607/NPO-18608).

Seraji, Homayoun↗

Control of free-flying space robot manipulator systems

To accelerate the development of multi-armed, free-flying satellite manipulators, a fixed-base cooperative manipulation facility is being developed. The work performed on multiple arm cooperation on a free-flying robot is summarized. Research is also summarized on global navigation and control of free-flying space robots. The Locomotion Enhancement via Arm Pushoff (LEAP) approach is described and progress to date is presented.

Cannon, Robert H., Jr.↗

Shuttle remote manipulator system workstation - Man-machine engineering

A major subsystem aboard the Shuttle Orbiter, the Remote Manipulator System (RMS) provides the capability to deploy and retrieve free-flying satellites, support attached payload operations, and aid in crewmember rescue from a disabled vehicle should the requirement arise. The Remote Manipulator System consists of 15.3-m (50 ft) articulated booms, end effectors, operator workstation, and closed circuit video, power and control subsystems. The manipulator booms (or arms) and end effectors are located in the Orbiter payload bay and operated from inside the cabin by one crewmember. This paper is primarily concerned with the design and development of the RMS operator's workstation, the man-machine engineering features and interfaces, and man-in-the-loop simulations and testing results obtained to date by the National Aeronautics and Space Administration (NASA).

Brown, J. W.↗

Design of a modular digital computer system

A Central Control Element (CCE) module which controls the Automatically Reconfigurable Modular System (ARMS) and allows both redundant processing and multi-computing in the same computer with real time mode switching, is discussed. The same hardware is used for either reliability enhancement, speed enhancement, or for a combination of both.

Source record↗

The direct observation of unidirectional solidification as a function of gravity level

A saturated solution of NH4 Cl-H2O was solidified unidirectionally on earth at 1 g and in a suborbital rocket at 0.001 g. In the 1 g experiment, extensive fluid flow was apparent, creating plumes which carry numerous crystallites vertically above the interface in a manner associated with freckling in castings. During growth the interface grew into the liquid at the same rate as the individual dendrites. When solidified in low g, the interface grew at a slower rate than the individual dendrites. No plumes of liquid carrying crystals were seen, but several crystals did appear and grow ahead of the interface. Growth rates, dendrite morphologies and preferred crystallographic orientations are compared for the two experiment conditions. Results indicate that solidification in low gravity produces more uniform dendrite arm spacings, and tends to be controlled by diffusion and crystallographic orientation.

Johnston, M. H.↗

High speed precision motion strategies for lightweight structures

Work during the recording period proceeded along the lines of the proposal, i.e., three aspects of high speed motion planning and control of flexible structures were explored: fine motion control, gross motion planning and control, and automation using light weight arms. In addition, modeling the large manipulator arm to be used in experiments and theory has lead to some contributions in that area. These aspects are reported below. Conference, workshop and journal submissions, and presentations related to this work were seven in number, and are listed. Copies of written papers and abstracts are included.

Book, Wayne J.↗

System architecture for the telerobotic work system

The functional and performance requirements and design concepts for a telerobotic work system (TWS) being considered as an adjunct to the Shuttle Remote Manipulator System and other applications are described. The multiple-armed free-flyer would be controlled by an operator in the Orbiter cabin and would perform remote sensing and manipulative tasks that EVA crew otherwise carry out. The TWS could also perform hazardous tasks, construction operations, and be an asset to the Space Station. Alternative system architectures are described, including the man-machine interface, the types of manipulators and their stowage, and the controls and backup systems. Potential terrestrial applications of the TWS concept, augmented with AI capabilities, are discussed.

Jenkins, Lyle M.↗