Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “argonne”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

Spin response and neutrino mean free path in neutron matter

The longitudinal and transverse density- and spin-density response functions in pure neutron matter (PNM) are derived over a wide range of densities within the time dependent local spin density approximation. The underlying density functional was derived from an Auxiliary Field Diffusion Monte Carlo computation of the equation of state of unpolarized and fully spin polarized PNM. In order to assess the dependence of the results on the specific underlying nucleon–nucleon Hamiltonian, we used both the phenomenological Argonne AV8' + UIX force, and local chiral forces up to next-to-next-to-leading-order (N 2 LO). Finally, the resulting response function has then been applied to the study of the neutrino mean free path in PNM.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Imaging and dosimetric characteristics of 67 Cu

In recent years the use of beta-emitting radiopharmaceuticals for cancer therapy has expanded rapidly following development of therapeutics for neuroendocrine tumors, prostate cancer, and other oncologic malignancies. One emerging beta-emitting radioisotope of interest for therapy is 67 Cu (t 1/2 : 2.6 d) due to its chemical equivalency with the widely-established positron-emitting isotope 64 Cu (t 1/2 : 12.7 h). Here we evaluate both the imaging and dosimetric characteristics of 67 Cu, as well as producing the first report of SPECT/CT imaging using 67 Cu. To this end, 67 Cu was produced by photon-induced reactions on isotopically-enriched 68 Zn at the Low-Energy Accelerator Facility (LEAF) of Argonne National Laboratory, followed by bulk separation of metallic 68 Zn by sublimation and radiochemical purification by column chromatography. Gamma spectrometry was performed by efficiency-calibrated high-purity germanium (HPGe) analysis to verify absolute activity calibration and establish radionuclidic purity. Absolute activity measurements corroborated manufacturer-recommended dose-calibrator settings and no radionuclidic impurities were observed. Using the Clinical Trials Network anthropomorphic chest phantom, SPECT/CT images were acquired. Medium Energy (ME) SPECT collimation was found to provide the best image quality from the primary 185 keV gamma emission of 67 Cu. Reconstructed images of 67 Cu were similar in quality to images acquired using 177 Lu. Recovery coefficients were calculated and compared against quantitative images of 99m Tc, 177 Lu, and 64 Cu within the same anthropomorphic chest phantom. Production and clinical imaging of 67 Cu appears feasible, and future studies investigating the therapeutic efficacy of 67 Cu-based radiopharmaceuticals are warranted.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Observation of a new isomer in {sup 185}Au

Delayed γ-ray spectroscopy of 185Au was studied at the Argonne Gas-Filled Analyzer. A new isomer at an excitation energy of 1504.2(4) keV with a half-life of 630(80) ns was identified via γ-γ coincidence analysis, decaying via a 294.8(3) keV transition. Based on Weisskopf estimates, the multipolarity of the 295 keV transition is assigned to be E1, M1, E2, or M2. Possible configurations for this new isomer are discussed based on configuration-constrained potential energy surface calculations.

Fu, X. Y.↗

Etched Silicon Planar CRL Optics for the High-Energy X-ray Diffraction Beamlines 11-ID-B and 11-ID-C at the APS

We report the focusing of high-energy X-rays is most commonly achieved by commercially available compound refractive lenses (CRL), which are added together in larger structures. There is a need for high-energy X-ray beamlines to enable focusing in only one dimension down to a few micrometers to study layered materials and thin films. High-energy X-rays above 50 keV require often 100 lenses or more, therefore it is more efficient to etch the complete arrays of lenses into a monolithic substrate like a silicon wafer. Custom lens arrays were fabricated for the high-energy x-ray beamlines 11-ID-B, and 11-ID-C at the Argonne National Laboratory. The fabrication required tuning parameters of the Bosch process to optimize the etching of deep vertical sidewalls at a reasonable speed without overheating. The beamline 11-ID-B is equipped with lens arrays of 85-110 lenses for 59 keV and 190-250 lenses for 87 keV photon energy, focusing the beam vertically below 5.0 µm at the sample positions between 1600 mm to 2100 mm. 11-ID-C has received arrays of 435 lenses that focus 106 keV X-rays to a vertical height of 2.0 µm at the sample position. In both cases, the flux density gain in the focal spot is larger than a factor of 20, relative to using slits to cut the beam size. The lens setup is permanently installed and can be moved in and out of the beam during the experiment without further alignment. The lenses have enabled operando diffraction studies on interfaces in batteries and the development of pair distribution function (PDF) analysis using grazing incidence geometry.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

{sup 58}Ni({sup 3}He,t){sup 58}Cu*({gamma}) Measurements with GODDESS to Constrain the Astrophysical Rate of {sup 57}Ni(p,{gamma}){sup 58}Cu

The observation of γ rays from the decay of 44Ti in the remnants of core-collapse supernovae (CCSNe) provides crucial information regarding the nucleosynthesis occurring in these events, as 44Ti production is sensitive to CCSNe conditions. The final abundance of 44Ti is also sensitive to specific nuclear input parameters, one of which is the 57Ni(p,γ) 58Cu reaction rate. A precise rate for 57Ni(p,γ) 58Cu is thus critical if 44Ti production is to be an effective probe into CCSNe. To experimentally constrain the 57Ni(p,γ) 58Cu rate, the structure properties of 58Cu were measured via the 58Ni(3He,t)58Cu*(γ) reaction using GODDESS (GRETINA ORRUBA Dual Detectors for Experimental Structure Studies) at Argonne National Laboratory’s ATLAS facility. Details of the experiment, ongoing analysis, and plans are presented.

Carmichael, S. R.↗

1.2 Mfps standalone X-ray detector for Time-Resolved Experiments

We present a standalone and autonomous X-ray detector capable of operation with the speed of up to1.2Mfps. The detector utilizes UFXC32k hybrid pixel detectors for sensing X-rays, Spartan-6 LX45 FPGA placed in commercially available sbRIO 9628 controller for data acquisition and processing including a compression with zero-suppression algorithm. A Linux-RT system working on the 400 MHz Dual-Core CPU is used for FPGA control and data streaming to the higher-level system over 1 Gbps Ethernet connection. 1.2 M frames per second is achieved in so-called burst mode of operation while in zerodead-time mode 70 kfps is possible. Due to efficient data compression in FPGA there’s no need of using high-speed transceivers and Frame-Grabber cards on the data server side and the detector can stream the data infinitely over standard 1 Gbps network connection. Operation modes were tested at Advanced Photon Source Synchrotron at Argonne National Laboratory.

47 OTHER INSTRUMENTATION↗

Visualisation of sulphur on single fibre level for pulping industry

In the pulp and paper industry, about 5 Mt/y chemithermomechanical pulp (CTMP) are produced globally from softwood chips for production of carton board grades. For tailor making CTMP for this purpose, wood chips are impregnated with aqueous sodium sulphite for sulphonation of the wood lignin. When lignin is sulphonated, the defibration of wood into pulp becomes more selective, resulting in enhanced pulp properties. On a microscopic fibre scale, however, one could strongly assume that the sulphonation of the wood structure is very uneven due to its macroscale size of wood chips. If this is the case and the sulphonation could be done significantly more evenly, the CTMP process could be more efficient and produce pulp even better suited for carton boards. Therefore, the present study aimed to develop a technique based on X-ray fluorescence microscopy imaging (µXRF) for quantifying the sulphur distribution on CTMP wood fibres. Firstly, the feasibility of µXRF imaging for sulphur homogeneity measurements in wood fibres needs investigation. Therefore, clarification of which spatial and spectral resolution that allows visualization of sulphur impregnation into single wood fibres is needed. Measurements of single fibre imaging were carried out at the Argonne National Laboratory's Advanced Photon Source (APS) synchrotron facility. With a synchrotron beam using one micrometre scanning step, images of elemental mapping are acquired from CTMP samples diluted with non-sulphonated pulp under specified conditions. Since the measurements show significant differences between sulphonated and non-sulphonated fibres, and a significant peak concentration in the shell of the sulphonated fibres, the proposed technique is found to be feasible. The required spatial resolution of the µXRF imaging for an on-site CTMP sulphur homogeneity measurement setup is about 15 µm, and the homogeneity measured along the fibre shells is suggested to be used as the CTMP sulphonation measurement parameter.

CTMP↗

Characterizing novel Indium Phosphide pad detectors with focused X-ray beams and laboratory tests

Future tracking systems in High Energy Physics experiments will require large instrumented areas with low radiation length. Crystalline silicon sensors have been used in tracking systems for decades, but are difficult to manufacture and costly to produce for large areas. We are exploring alternative sensor materials that are amenable to fast fabrication techniques used for thin film devices. Indium Phosphide pad sensors were fabricated at Argonne National Lab using commercially available InP:Fe 2-inch mono-crystal substrates. Current-voltage and capacitance-voltage characterizations were performed to study the basic operating characteristics of a group of sensors. Micro-focused X-ray beams at Canadian Light Source and Diamond Light Source were used to study the response to ionizing radiation, and characterize the uniformity of the response for several devices. Electrical test results showed a high degree of performance uniformity between the 48 tested devices. X-ray test beam results showed good performance uniformity within tested devices after accounting for spatially-local defects and edge fields. As a result, this motivates further studies into thin film devices for future tracking detectors.

47 OTHER INSTRUMENTATION↗

End-to-end AI framework for interpretable prediction of molecular and crystal properties

We introduce an end-to-end computational framework that allows for hyperparameter optimization using the DeepHyper library, accelerated model training, and interpretable AI inference. The framework is based on state-of-the-art AI models including CGCNN, PhysNet, SchNet, MPNN, MPNN-transformer, and TorchMD-NET. We employ these AI models along with the benchmark QM9, hMOF, and MD17 datasets to showcase how the models can predict user-specified material properties within modern computing environments. We demonstrate transferable applications in the modeling of small molecules, inorganic crystals and nanoporous metal organic frameworks with a unified, standalone framework. We have deployed and tested this framework in the ThetaGPU supercomputer at the Argonne Leadership Computing Facility, and in the Delta supercomputer at the National Center for Supercomputing Applications to provide researchers with modern tools to conduct accelerated AI-driven discovery in leadership-class computing environments. We release these digital assets as open source scientific software in GitLab, and ready-to-use Jupyter notebooks in Google Colab.

36 MATERIALS SCIENCE↗

Physics-inspired spatiotemporal-graph AI ensemble for the detection of higher order wave mode signals of spinning binary black hole mergers

We present a new class of AI models for the detection of quasi-circular, spinning, non-precessing binary black hole mergers whose waveforms include the higher order gravitational wave modes ($\ell$, |m|) = {(2,2), (2,1), (3,3), (3,2), (4,4)}, and mode mixing effects in the $\ell$ = 3, |m| = 2 harmonics. These AI models combine hybrid dilated convolution neural networks to accurately model both short- and long-range temporal sequential information of gravitational waves; and graph neural networks to capture spatial correlations among gravitational wave observatories to consistently describe and identify the presence of a signal in a three detector network encompassing the Advanced LIGO and Virgo detectors. We first trained these spatiotemporal-graph AI models using synthetic noise, using 1.2 million modeled waveforms to densely sample this signal manifold, within 1.7 h using 256 NVIDIA A100 GPUs in the Polaris supercomputer at the Argonne Leadership Computing Facility. This distributed training approach exhibited optimal classification performance, and strong scaling up to 512 NVIDIA A100 GPUs. With these AI ensembles we processed data from a three detector network, and found that an ensemble of 4 AI models achieves state-of-the-art performance for signal detection, and reports two misclassifications for every decade of searched data. We distributed AI inference over 128 GPUs in the Polaris supercomputer and 128 nodes in the Theta supercomputer, and completed the processing of a decade of gravitational wave data from a three detector network within 3.5 h. Finally, we fine-tuned these AI ensembles to process the entire month of February 2020, which is part of the O3b LIGO/Virgo observation run, and found 6 gravitational waves, concurrently identified in Advanced LIGO and Advanced Virgo data, and zero false positives. This analysis was completed in one hour using one NVIDIA A100 GPU.

79 ASTRONOMY AND ASTROPHYSICS↗

Electric Vehicles, Biofuels, and Transitions in Transportation Energy

The decarbonization of power sources for light duty transportation is moving towards the use of renewable energies, biofuels, and electric vehicles. Currently there are three major light transportation fuels: gasoline (US gasoline is 98% E10), biofuels (E85), and electricity. Currently fuel ethanol in biofuels is obtained principally from corn in the US and sugarcane in Brazil with a small amount from cellulose. The transition to alternative fuels has been occurring since 1980, although light transportation still relies on gasoline. The rise of battery electric vehicles (BEV) is now beginning to offset internal combustion engines (ICE), while recent advances in biotechnology and integrated plant design have enhanced the economic feasibility of cellulosic biofuels. This paper explores the potential role of these fuels in reducing the carbon footprint associated with light transportation. We compare three different cases: Gasoline, E85 and full electric based on the Argonne AFLEET tool to calculate generation of greenhouse gases due to manufacturing and operation of BEV and ICE cars, respectively, in the US assuming an average useful automobile life of 200,000 miles or 12 years. We concluded that significant liquid fuel use (both renewable and non-renewable) will continue for the next 50 years. Here, renewable liquid fuels have an important role to play as the transportation sector transitions from petroleum to other energy sources.

09 BIOMASS FUELS↗

Applying ALARA Principles in the Design of New Radiological Facilities

The application of ALARA (As Low As Reasonably Achievable) principles to the design of new radiological facilities at Argonne National Laboratory provides a consistent radiation safety basis for future facility operations. The Department of Energy Rule 10 CFR 835 specifies design objectives to be adopted during the design of new facilities for controlling personal radiation exposure. One is to keep exposure levels below 20% of the applicable standards in 10 CFR 835.202. For a radiation worker 20% of the standard corresponds to 5 µSv hr -1 for a 2,000 hour work year. For a member of the public the DOE design objective corresponds to 0.2 mSv in a calendar year. For a new facility worst case radionuclides and their source strengths are chosen. Local shielding is specified to reduce exposure rates to less than 50 µSv hr -1 at 30 cm from the shielding. The current version MCNP6 of the Los Alamos radiation shielding computer program MCNP is then used to calculate the exposure rates elsewhere. Design modifications are made to meet the criteria. The calculations and resulting facility design modifications are discussed for two new radiological facilities.

61 RADIATION PROTECTION AND DOSIMETRY↗

Excited levels in odd-A silver isotopes populated rn fission of {sup 252}Cf

Excited levels in 111−121 Ag , odd-𝐴 isotopes populated following spontaneous fission of 252 Cf have been studied using high-fold 𝛾 coincidences measured with Gammasphere array of Compton-suppressed Ge spectrometers at Argonne National Laboratory. The experimental information on these nuclei reported before has been corrected and extended. In the work we discuss the evolution of triaxiality in odd-Ag nuclei. Relative positions of the 𝜋⁢𝑝1/2 and 𝜋⁢𝑔9/2 shells defining the 𝑍=40 gap when approaching the 𝑁=82 closure, the 𝜋⁢1/2+⁢[431] intruder bands, the three-quasiparticle configurations, and the so called 𝑗−1 anomaly in odd-Ag nuclei are also discussed.

Urban, W.↗

Na 22 activation level measurements of fused silica rods in the LHC target absorber for neutrals compared to simulations

The Target Absorbers for Neutrals (TANs) are located in a high intensity radiation environment inside the tunnel of the Large Hadron Collider (LHC). TANs are positioned about 140 m downstream from the beam interaction points. Seven 40-cm long fused silica rods with different dopant specifications were irradiated in the TAN by the Beam RAte of Neutrals (BRAN) detector group during p + p data taking from 2016 to 2018 at the LHC. The peak dose delivered to the fused silica rods was 18 MGy. We report measurements of the 22 Na activation of the fused silica rods carried out at the University of Illinois at Urbana-Champaign and Argonne National Laboratory. At the end of the irradiation campaign, the maximum 22 Na activity observed was A = 21 kBq/cm 3 corresponding to a density, ρ = 2.5 x 10 12 /cm 3 , of 22 Na nuclei. FLUKA Monte Carlo simulations have been performed by the CERN FLUKA team to estimate 22 Na activities for the irradiated BRAN rod samples. The simulations reproduce the 22 Na activity profile measured along the rods, with a 35% underestimation of the experimental measurement results.

43 PARTICLE ACCELERATORS↗

Four-dimensional phase-space reconstruction of flat and magnetized beams using neural networks and differentiable simulations

Beams with cross-plane coupling or extreme asymmetries between the two transverse phase spaces are often encountered in particle accelerators. Flat beams with large transverse-emittance ratios are critical for future linear colliders. Similarly, magnetized beams with significant cross-plane coupling are expected to enhance the performance of electron cooling in hadron beams. Preparing these beams requires precise control and characterization of the four-dimensional transverse phase space. In this study, we employ generative phase-space reconstruction techniques to rapidly characterize magnetized and flat-beam phase-space distributions using a conventional quadrupole-scan method. The reconstruction technique is experimentally demonstrated on an electron beam produced at the Argonne Wakefield Accelerator and successfully benchmarked against conventional diagnostics techniques. Specifically, we show that predicted beam parameters from the reconstructed phase-space distributions (e.g., as magnetization and flat-beam emittances) are in excellent agreement with those measured from the conventional diagnostic methods. Published by the American Physical Society 2024

43 PARTICLE ACCELERATORS↗

Efficient six-dimensional phase space reconstructions from experimental measurements using generative machine learning

Next-generation accelerator concepts, which hinge on the precise shaping of beam distributions, demand equally precise diagnostic methods capable of reconstructing beam distributions within six-dimensional position-momentum spaces. However, the characterization of intricate features within six-dimensional beam distributions using current diagnostic techniques necessitates a substantial number of measurements, using many hours of valuable beam time. Novel phase space reconstruction techniques are needed to reduce the number of measurements required to reconstruct detailed, high-dimensional beam features in order to resolve complex beam phenomena and as a feedback in precision beam shaping applications. In this study, we present a novel approach to reconstructing detailed six-dimensional phase space distributions from experimental measurements using generative machine learning and differentiable beam dynamics simulations. We demonstrate that this approach can be used to resolve six-dimensional phase space distributions from scratch, using basic beam manipulations and as few as 20 two-dimensional measurements of the beam profile. We also demonstrate an application of the reconstruction method in an experimental setting at the Argonne Wakefield Accelerator, where it is able to reconstruct the beam distribution and accurately predict previously unseen measurements 75× faster than previous methods.

43 PARTICLE ACCELERATORS↗

X-ray diagnostics for the cavity-based x-ray free-electron laser project

The success of x-ray free-electron lasers (XFELs) in recent years has greatly advanced many scientific fields. However, most of these XFELs suffer from a low longitudinal coherence and instabilities due to the stochastic start-up process. A cavity-based x-ray free-electron laser (CBXFEL) is a possible future direction in the development of fully coherent and stable x-ray sources. One of the challenges of a CBXFEL is the requirement for the μ⁢m−sized electron bunches to fully overlap in three dimensions with the circulating μ⁢m−sized x-ray pulses in an x-ray cavity tens or hundreds of meters long. We present here the development of an x-ray diagnostics system for accurate alignment of x-ray beams in the CBXFEL cavity. The system was developed within the framework of a CBXFEL research and development collaboration among Argonne National Laboratory, SLAC National Accelerator Laboratory, and Spring-8. All the designed diagnostic components have been fully characterized at the Advanced Photon Source to demonstrate a capability for sub-μ⁢rad angular and μ⁢m spatial alignment of the CBXFEL cavity.

Free-electron lasers↗

Temperature Mapping of Stacked Silicon Dies from X-Ray-Diffraction Intensities

Increasing power densities in integrated circuits have led to an increased prevalence of thermal hotspots in integrated circuits. Tracking these thermal hotspots is imperative to prevent circuit failures. In three- dimensional (3D) integrated circuits, conventional surface techniques like infrared thermometry are unable to measure the 3D temperature distribution, and optical and magnetic resonance techniques are difficult to apply due to the presence of metals and large current densities. X-rays offer a high penetration depth and can be used to probe 3D structures. We report a method utilizing the temperature dependence of x-ray-diffraction intensity via the Debye-Waller factor to simultaneously map the temperature of individual silicon dies in a stack. Here, utilizing beamline 1-ID-E at the Advanced Photon Source (Argonne), we demonstrate, for each individual silicon die, a temperature resolution of 3 K, a spatial resolution of 100 × 400 μm 2 , and a temporal resolution of 20 s. Utilizing a sufficiently high-intensity laboratory source, e.g., from a liquid-anode source, this method can be scaled down to laboratories for noninvasive temperature mapping of 3D integrated circuits.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗