Accurate calculation of control-augmented structural eigenvalue sensitivities using reduced-order models

A method is presented for generating mode shapes for model order reduction in a way that leads to accurate calculation of eigenvalue derivatives and eigenvalues for a class of control augmented structures. The method is based on treating degrees of freedom where control forces act or masses are changed in a manner analogous to that used for boundary degrees of freedom in component mode synthesis. It is especially suited for structures controlled by a small number of actuators and/or tuned by a small number of concentrated masses whose positions are predetermined. A control augmented multispan beam with closely spaced natural frequencies is used for numerical experimentation. A comparison with reduced-order eigenvalue sensitivity calculations based on the normal modes of the structure shows that the method presented produces significant improvements in accuracy.

Livne, Eli↗

Contact Analog/Compressed Symbology Heading Tape Assessment

A simulation assessed the performance, handling qualities and workload associated with a contact-analog, world-referenced heading tape as implemented on the Comanche Helmet Integrated Display Sight System (HIDSS) when compared with a screen-fixed, compressed heading tape. Six pilots, four active duty Army Aviators and two civilians flew three ADS-33 maneuvers and a traffic pattern in the Ames Vertical Motion Simulation facility. Small, but statistically significant advantages were found for the compressed symbology for handling qualities, workload, and some of the performance measures. It should be noted however that the level of performance and handling qualities for both symbology sets fell within the acceptable tolerance levels. Both symbology sets yield satisfactory handling qualities and performance in velocity stabilization mode and adequate handling qualities in the automatic flight control mode. Pilot comments about the contact analog symbology highlighted the lack of useful rate of change information in the heading tape and "blurring" due to the rapid movement of the heading tape. These issues warrant further study. Care must be taken in interpreting the operational significance of these results. The symbology sets yielded categorically similar data, i.e., acceptable handling qualities and adequate performance, so while the results point to the need for further study, their operational significance has yet to be determined.

Shively, R. Jay↗

Electrical Switching of Nematic Plasmonic Nanocolloids for Infrared Solar Gain Control

Controlling solar gain is essential to reduce the energy consumption by residential and commercial buildings, which are responsible for ≈40% of all energy generated globally. However, the dynamic control of solar gain in the near-infrared that corresponds to ≈50% of the overall Sun's energy at the Earth's surface, separately from the visible spectral range has been a challenge, albeit commercial coatings provide passive control while retaining highly visible transmission. To address this problem, in this paper switchable silver colloids (SSCs) are demonstrated, colloidal analogs of the common silver coatings used for solar gain control. When dispersed in a nematic liquid crystal, orientations of such plasmonic silver nanoplates are controlled by ≈1 V low-voltage electric fields, allowing for sub-second switching of the near-infrared-based solar gain. Installed and retrofit products made from thin films of such nanoplate dispersions confined between glass and plastic substrates, respectively, exhibit electrically controlled infrared-based solar gain while retaining high visible-range transparency, low haze, and high color rendering index. Furthermore, this study's findings reveal a great potential of soft-matter systems in addressing energy-related problems.

36 MATERIALS SCIENCE↗

Control System for RF OPM

SAND2025-01910O This software built in LabVIEW FPGA provides experimental control of the RF OPM prototype via a reconfigurable NI I/O card. It samples the analog input, processes it on the FPGA in real time, and generates control and feedback outputs to control and optimize the operation of the device. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525.

Bainbridge, Jonathan↗

Spline Curves, Wire Frames and Bvalue

The methods that were developed for wire-frame design are described. The principal tools for control of a curve during interactive design are mathematical ducks. The simplest of these devices is an analog of the draftsman's lead weight that he uses to control a mechanical spline also create Ducks for controlling differential and integral properties of curves were created. Other methods presented include: constructing the end of a Bezier polygon to gain quick and reasonably confident control of the end tangent vector, end curvature and end torsion; keeping the magnitude of unwanted curvature oscillations within tolerance; constructing the railroad curves that appear in many engineering design problems; and controlling the frame to minimize errors at mesh points and to optimize the shapes of the curve elements.

Smith, L.↗

Preliminary investigation of the control of a gas-turbine engine for a helicopter / Richard P. Krebs

An analog investigation of the power plant for a gas-turbine powered helicopter indicates that currently proposed turbine-propeller engine controls are satisfactory for helicopter application. Power increases from one-half to full rated at altitudes from sea level to 15,000 feet could be made in less than 4 seconds with either the rotor or propellers absorbing the engine power.

ENGINES, CONTROL - TURBINE-PROPELLER ENGINES↗

Quantifying the impact of precision errors on quantum approximate optimization algorithms

The quantum approximate optimization algorithm (QAOA) is a hybrid quantum-classical algorithm that seeks to achieve approximate solutions to optimization problems by iteratively alternating between intervals of controlled quantum evolution. Here, we examine the effect of analog precision errors on QAOA performance from the perspective of both algorithmic training and performance guarantees. Leveraging cumulant expansions, we recast the faulty QAOA as a control problem in which precision errors are expressed as multiplicative control noise and derive bounds on the performance of QAOA. We show using both analytical techniques and numerical simulations that fixed precision implementations of QAOA circuits are subject to an exponential degradation in performance dependent upon the number of optimal QAOA layers and magnitude of the precision error. Despite this significant reduction, we show that it is possible to mitigate precision errors in QAOA via digitization of the variational parameters at the cost of increasing circuit depth.

quantum algorithms↗

Advanced Data Acquisition Systems

Current and future requirements of the aerospace sensors and transducers field make it necessary for the design and development of new data acquisition devices and instrumentation systems. New designs are sought to incorporate self-health, self-calibrating, self-repair capabilities, allowing greater measurement reliability and extended calibration cycles. With the addition of power management schemes, state-of-the-art data acquisition systems allow data to be processed and presented to the users with increased efficiency and accuracy. The design architecture presented in this paper displays an innovative approach to data acquisition systems. The design incorporates: electronic health self-check, device/system self-calibration, electronics and function self-repair, failure detection and prediction, and power management (reduced power consumption). These requirements are driven by the aerospace industry need to reduce operations and maintenance costs, to accelerate processing time and to provide reliable hardware with minimum costs. The project's design architecture incorporates some commercially available components identified during the market research investigation like: Field Programmable Gate Arrays (FPGA) Programmable Analog Integrated Circuits (PAC IC) and Field Programmable Analog Arrays (FPAA); Digital Signal Processing (DSP) electronic/system control and investigation of specific characteristics found in technologies like: Electronic Component Mean Time Between Failure (MTBF); and Radiation Hardened Component Availability. There are three main sections discussed in the design architecture presented in this document. They are the following: (a) Analog Signal Module Section, (b) Digital Signal/Control Module Section and (c) Power Management Module Section. These sections are discussed in detail in the following pages. This approach to data acquisition systems has resulted in the assignment of patent rights to Kennedy Space Center under U.S. patent # 6,462,684. Furthermore, NASA KSC commercialization office has issued licensing rights to Circuit Avenue Netrepreneurs, LLC , a minority-owned business founded in 1999 located in Camden, NJ.

Perotti, J.↗

Pulse-modulated dual-gas control subsystem for space cabin atmosphere

An atmosphere control subsystem (ACS) was developed for use in a closed manned cabin, such as the Space Shuttle Orbiter. This subsystem uses the Perkin Elmer mass spectrometer for continuous measurement of major atmospheric constituents (H2, H2O, N2, O2, and CO2). The O2 and N2 analog signals are used as inputs to the controller, which produces a pulse-frequency-modulated output to operate the N2 gas admission solenoid valve and an on-off signal to operate the O2 valve. The proportional controller characteristic results in improved control accuracy as compared with previously used on-off controllers having significant dead-band. A 60-day evaluation test was performed on the ACS during which operation was measured at various values of control setpoint and simulated cabin leakage.

Jackson, J. K.↗

EXTRACTING HUMAN RELIABILITY FINDINGS FROM HUMAN FACTORS STUDIES IN THE HUMAN SYSTEMS SIMULATION LABORATORY

Modernization of U.S. nuclear power plants (NPPs) is widespread, with most plants currently replacing and transitioning equipment, control systems, and human system interfaces (HSI)s from analog to digital displays. This conversion remedies the obsolescence of analog parts along with needs for increased intuitiveness of design, safety, and capabilities. The Human Factors and Reliability team at Idaho National Laboratory (INL) carried out twelve control room modernization studies in the newly designed Human Systems Simulation Laboratory (HSSL) over nine years. The HSSL was constructed as a testbed for evaluating human factors techniques and performance measures, HSI frameworks, and cutting-edge operational concepts in NPPs. Installing a full-scope training simulator enabled direct design and evaluation work on the same instrumentation and control (I&C) and HSIs located at U.S. plants. The subsequent addition of glass top bays afforded crews opportunities to implement operations via the simulator using full-scale representations of their home NPP. Additionally, functional HSI prototypes were created, providing an environment for operator-in-the-loop benchmark studies. The HSSL has assisted in upgrades of six commercial NPP control rooms and served as an invaluable proving ground for new NPP operations technology. Human reliability analysis (HRA) was not originally the focus of the studies; however, data relating to HRA such as type and frequency of human errors can be extracted from the studies. INL is currently extracting data from the HSSL study reports to apprise how information gathered from simulation, HSI, and other related studies can create a broad look across different data sources to help inform HRA methods.

99 GENERAL AND MISCELLANEOUS↗

FPGA Flash Memory High Speed Data Acquisition

The purpose of this research is to design and implement a VHDL ONFI Controller module for a Modular Instrumentation System. The goal of the Modular Instrumentation System will be to have a low power device that will store data and send the data at a low speed to a processor. The benefit of such a system will give an advantage over other purchased binary IP due to the capability of allowing NASA to re-use and modify the memory controller module. To accomplish the performance criteria of a low power system, an in house auxiliary board (Flash/ADC board), FPGA development kit, debug board, and modular instrumentation board will be jointly used for the data acquisition. The Flash/ADC board contains four, 1 MSPS, input channel signals and an Open NAND Flash memory module with an analog to digital converter. The ADC, data bits, and control line signals from the board are sent to an Microsemi/Actel FPGA development kit for VHDL programming of the flash memory WRITE, READ, READ STATUS, ERASE, and RESET operation waveforms using Libero software. The debug board will be used for verification of the analog input signal and be able to communicate via serial interface with the module instrumentation. The scope of the new controller module was to find and develop an ONFI controller with the debug board layout designed and completed for manufacture. Successful flash memory operation waveform test routines were completed, simulated, and tested to work on the FPGA board. Through connection of the Flash/ADC board with the FPGA, it was found that the device specifications were not being meet with Vdd reaching half of its voltage. Further testing showed that it was the manufactured Flash/ADC board that contained a misalignment with the ONFI memory module traces. The errors proved to be too great to fix in the time limit set for the project.

Gonzalez, April↗

Automated Cryocooler Monitor and Control System

A system was designed to automate cryogenically cooled low-noise amplifier systems used in the NASA Deep Space Network. It automates the entire operation of the system including cool-down, warm-up, and performance monitoring. The system is based on a single-board computer with custom software and hardware to monitor and control the cryogenic operation of the system. The system provides local display and control, and can be operated remotely via a Web interface. The system controller is based on a commercial single-board computer with onboard data acquisition capability. The commercial hardware includes a microprocessor, an LCD (liquid crystal display), seven LED (light emitting diode) displays, a seven-key keypad, an Ethernet interface, 40 digital I/O (input/output) ports, 11 A/D (analog to digital) inputs, four D/A (digital to analog) outputs, and an external relay board to control the high-current devices. The temperature sensors used are commercial silicon diode devices that provide a non-linear voltage output proportional to temperature. The devices are excited with a 10-microamp bias current. The system is capable of monitoring and displaying three temperatures. The vacuum sensors are commercial thermistor devices. The output of the sensors is a non-linear voltage proportional to vacuum pressure in the 1-Torr to 1-millitorr range. Two sensors are used. One measures the vacuum pressure in the cryocooler and the other the pressure at the input to the vacuum pump. The helium pressure sensor is a commercial device that provides a linear voltage output from 1 to 5 volts, corresponding to a gas pressure from 0 to 3.5 MPa (approx. = 500 psig). Control of the vacuum process is accomplished with a commercial electrically operated solenoid valve. A commercial motor starter is used to control the input power of the compressor. The warm-up heaters are commercial power resistors sized to provide the appropriate power for the thermal mass of the particular system, and typically provide 50 watts of heat. There are four basic operating modes. "Cool " mode commands the system to cool to normal operating temperature. "Heat " mode is used to warm the device to a set temperature near room temperature. "Pump " mode is a maintenance function that allows the vacuum system to be operated alone to remove accumulated contaminants from the vacuum area. In "Off " mode, no power is applied to the system.

Britcliffe, Michael J.↗

LP-search and its use in analysis of the accuracy of control systems with acoustical models

The LP-search is proposed as an analog of the Monte Carlo method for finding values in nonlinear statistical systems. It is concluded that: To attain the required accuracy in solution to the problem of control for a statistical system in the LP-search, a considerably smaller number of tests is required than in the Monte Carlo method. The LP-search allows the possibility of multiple repetitions of tests under identical conditions and observability of the output variables of the system.

Sergeyev, V. I.↗

Robust Control for Microgravity Vibration Isolation using Fixed Order, Mixed H2/Mu Design

Many space-science experiments need an active isolation system to provide a sufficiently quiescent microgravity environment. Modern control methods provide the potential for both high-performance and robust stability in the presence of parametric uncertainties that are characteristic of microgravity vibration isolation systems. While H2 and H(infinity) methods are well established, neither provides the levels of attenuation performance and robust stability in a compensator with low order. Mixed H2/H(infinity), controllers provide a means for maximizing robust stability for a given level of mean-square nominal performance while directly optimizing for controller order constraints. This paper demonstrates the benefit of mixed norm design from the perspective of robustness to parametric uncertainties and controller order for microgravity vibration isolation. A nominal performance metric analogous to the mu measure, for robust stability assessment is also introduced in order to define an acceptable trade space from which different control methodologies can be compared.

Whorton, Mark↗

Robust Control for The G-Limit Microgravity Vibration Isolation System

Many microgravity science experiments need an active isolation system to provide a sufficiently quiescent acceleration environment. The g-LIMIT vibration isolation system will provide isolation for Microgravity Science Glovebox experiments in the International Space Station. While standard control system technologies have been demonstrated for these applications, modern control methods have the potential for meeting performance requirements while providing robust stability in the presence of parametric uncertainties that are characteristic of microgravity vibration isolation systems. While H2 and H infinity methods are well established, neither provides the levels of attenuation performance and robust stability in a compensator with low order. Mixed H2/mu controllers provide a means for maximizing robust stability for a given level of mean-square nominal performance while directly optimizing for controller order constraints. This paper demonstrates the benefit of mixed norm design from the perspective of robustness to parametric uncertainties and controller order for microgravity vibration isolation. A nominal performance metric analogous to the mu measure for robust stability assessment is also introduced in order to define an acceptable trade space from which different control methodologies can be compared.

Whorton, Mark S.↗

Harnessing Particle Size‐Control and DNA‐Oligo Functionalization in ZIF‐76 for Biological Applications

Abstract Advanced therapeutics require novel nanocarriers to ensure their functionality is preserved during transit. Zeolitic imidazolate frameworks (ZIFs) have emerged as promising materials in this field owing to their combined biocompatibility, high porosity, and tunable chemistry. While a diverse family of ZIFs has been reported, few have been explored beyond the prototypical ZIF‐8. Herein, the size‐controlled synthesis of three distinct ZIF‐76 analogs is demonstrated, overcoming the unique synthetic challenges intrinsic to the lta topology and complex crystallization kinetics associated with the mixed linker approach. This assesses the materials’ platform effectiveness for intracellular delivery first by exploring the structural and colloidal stability in biologically relevant media. To circumvent particle aggregation, fluorescently labeled DNA oligonucleotides are post‐synthetically attached to the ZIF surface. This modification significantly improves the colloidal stability in media and facilitates particle internalization tracking. Finally, the particle‐cell interactions are assessed, revealing rapid cell membrane association with macrophages, but not lung epithelial cells, and ZIF accumulation within macrophages which increased over time. Importantly, this study outlines a generalized approach toward expanding the available library of ZIFs for biological applications, enabling the potential for targeted therapeutic delivery for intracellular infections treatment.

Deneff, Jacob I.↗

Wet to Dry Controls Lanthanide Scandate Synthesis

The choice of temperature and gas conditions used in a water pressure-controlled reactor is guided by density functional theory (DFT) to synthesize nearly phase pure lanthanide scandate nanoparticles (LnScO 3 , Ln = La, Nd, Sm, Gd). In this synthetic method, low water vapor partial pressures, well below water’s gas liquidus, inhibit particle growth, while an excess of water vapor results in undesired rare earth hydroxide and oxyhydroxide secondary phases. The optimal humidity for high-purity LnScO 3 particle synthesis is shown to vary with the lanthanide; DFT is used to calculate the thermodynamics of secondary phase formation for each lanthanide tested, such that the role of water vapor may be quantified and used to maintain phase purity (greater than 96 mol%) across the series. Furthermore, the combination of thermodynamic calculation and experimental confirmation with this pressure-controlled reactor provides an opportunity to explore analogous syntheses of other inorganic perovskite nanoparticles.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Reconfiguring DNA Nanotube Architectures via Selective Regulation of Terminating Structures

Molecular assemblies inside cells often undergo structural reconfiguration in response to stimuli to alter their function. Adaptive reconfiguration of cytoskeletal networks, for example, enables cellular shape change, movement, and cargo transport and plays a key role in driving complex processes such as division and differentiation. The cellular cytoskeleton is a self-assembling polymer network composed of simple filaments, so reconfiguration often occurs through the rearrangement of its component filaments’ connectivities. DNA nanotubes have emerged as promising building blocks for constructing programmable synthetic analogs of cytoskeletal networks. Nucleating seeds can control when and where nanotubes grow and capping structures can bind nanotube ends to stop growth. Such seeding and capping structure, collectively called termini, can organize nanotubes into larger architectures. However, these structures cannot be selectively activated or inactivated in response to specific stimuli to rearrange nanotube architectures, a key property of cytoskeletal networks. Here we demonstrate how selective regulation of the binding affinity of DNA nanotube termini for DNA nanotube monomers or nanotube ends can direct the reconfiguration of nanotube architectures. Using DNA hybridization and strand displacement reactions that specifically activate or inactivate four orthogonal nanotube termini, we demonstrate that nanotube architectures can be reconfigured by selective addition or removal of unique termini. Lastly, we show how terminus activation could be a sensitive detector and amplifier of a DNA sequence signal. These results could enable the development of adaptive and multifunctional materials or diagnostic tools.

59 BASIC BIOLOGICAL SCIENCES↗