Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ampere”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

The 250AH/90A active lithium-thionyl chloride cell for Centaur-G application

A high rate active Li/SOCl2 cell was designed for use in a 28 volt, 250 amp-hour space battery system. The lithium battery is being considered as a replacement of its heavier silver-zinc counterpart on board the Centaur-G booster rocket which is used to launch payloads from the Space Shuttle cargo bay into deep-space. Basically a feasibility study, this development effort is demonstrating the ability of the lithium cell to deliver up to 90 amps safely at power densities of approximately 25 watts per pound. Test data on 4 prototype units is showing an energy density of 85 watt-hours per pound and 9.0 watt-hours/cu in. The cells tested typically delivered 280 to 300 amp-hours under ambient temperature test conditions using alternating continuous loads of 90, 55, and 20 amperes throughout life. Data from four cells tested are presented to demonstrate the capability of Li/SOCl2 technology for a C/3 discharge rate in active and hermetic cell units.

Zolla, A. E.↗

Plasma contactors for use with electodynamic tethers for power generation

Plasma contactors are proposed as a means of making good electrical contact between biased surfaces such as found at the ends of an electrodynamic tether and the space environment. The plasma contactor emits a plasma cloud which facilitates the electrical connection. The physics of this plasma cloud is investigated for contactors used as electron collectors. The central question addressed is whether the electrons collected by a plasma contactor come from the far field or by ionization of local neutral gas. This question is important because the system implications are different for the two mechanisms. It is shown that contactor clouds in space will consist of a spherical core possibly containing a shock wave. Outside of the core the cloud will expand anisotropically across the magnetic field leading to a turbulent cigar shape structure along the field. This outer region is itself divided into two regions by the ion response to the electric field. A two-dimensional theory for the outer regions of the cloud is developed. The current voltage characteristic of an Argon plasma contactor cloud is estimated for several ion currents in the range of 1 to 100 Amperes. It is suggested that the major source of collected electrons comes by ionization of neutral gas while collection of electrons from the far field is relatively small.

Hastings, D. E.↗

Component variations and their effects on bipolar nickel-hydrogen cell performance

A 50 cell bipolar nickel-hydrogen battery was assembled to demonstrate the feasibility of constructing a high voltage stack of cells. Various component combinations were tested in this battery. The battery had approximately 1 ampere-hour of capacity and was constructed from components with an active area of 2 x 2 inches. The components were parametrically varied to give a comparison of nickel electrodes, hydrogen electrodes, separators, fill procedures and electrolyte reservoir plate thicknesses. Groups of five cells were constructed using the same components; ten combinations were tested in all. The battery was thoroughly characterized at various change and discharge rates as well as with various pulse patterns and rates. Over a period of 1400 40-percent DOD LEO cycles some of the groups began to exhibit performance differences. In general, only separator variations had a significant effect on cell performance. It also appears that shunt currents may have been operating within the stack, resulting in electrolyte transfer from one cell to another, thus contributing to cell performance variations.

Manzo, Michelle A.↗

Plasma contactors for use with electrodynamic tethers for power generation

Plasma contactors have been proposed as a means of making good electrical contact between biased surfaces such as found at the ends of an electrodynamic tether and the space environment. A plasma contactor is a plasma source which emits a plasma cloud which facilitates the electrical connection. The physics of this plasma cloud is investigated for contactors used as electron collectors and it is shown that contactor clouds in space will consist of a spherical core possibly containing a shock wave. Outside of the core the cloud will expand anisotropically across the magnetic field leading to a turbulent cigar shape structure along the field. This outer region is itself divided into two regions by the ion response to the electric field. A two dimensional theory of the motion of the cloud across the magnetic field is developed. The current voltage characteristic of an Argon plasma contactor cloud is estimated for several ion currents in the range of 1-100 Amperes. It is shown that small ion current contactors are more efficient than large ion current contactors. This suggests that if a plasma contactor is used on an electrodynamic tether, then a multiple tether array will be more efficient than a single tether.

Hastings, D. E.↗

Feasibility of using high temperature superconducting magnets and conventional magnetic loop antennas to attract or repel objects at the space station

A study was undertaken to see if magnetic forces can be used at the Space Station to attract or repel spacecrafts such as the Orbital Manuevering Vehicle (OMV) or the Orbiter. A large magnet, in the form of a current loop, is assumed to be placed at the Space Station and another one on the spacecraft. The expression for the force between the two dipoles (loops) is obtained. Using a force of 15 Newtons (3.4 pounds) in order to move the spacecraft, the number of ampere-turn needed in the current loops was calculated at various distances between them. The expression for the force of attraction between a current loop and a soft magnetic material was also examined and the number of amp-turn needed to provide a force of one-tenth of a pound at various distances is also calculated. This one tenth of a pound force would be used in a life line system for the retrieval of an adrift crewman or tool at the Space Station. The feasibility of using conventional antenna on the Station and the incoming vehicle for attraction or repulsion was also examined.

Randhawa, Manjit S.↗

Development and simulation study of a new inverse-pinch high Coulomb transfer switch

The inverse-pinch plasma switch was studied using a computer simulation code. The code was based on a 2-D, 2-temperature magnetohydrodynamic (MHD) model. The application of this code was limited to the disk-type inverse-pinch plasma switch. The results of the computer analysis appear to be in agreement with the experimental results when the same parameters are used. An inverse-pinch plasma switch for closing has been designed and tested for high-power switching requirements. An azimuthally uniform initiation of breakdown is a key factor in achieving an inverse-pinch current path in the switch. Thus, various types of triggers, such as trigger pins, wire-brush, ring trigger, and hypocycloidal-pinch (HCP) devices have been tested for uniform breakdown. Recently, triggering was achieved by injection of a plasma-ring (plasma puff) that is produced separately with hypocycloidal-pinch electrodes placed under the cathode of the main gap. The current paths at switch closing, initiated by the injection of a plasma-ring from the HCP trigger are azimuthally uniform, and the local current density is significantly reduced, so that damage to the electrodes and the insulator surfaces is minimized. The test results indicate that electron bombardment on the electrodes and the insulator surfaces is minimized. The test results indicate that electron bombardment on the electrodes is four orders of magnitude less than that of a spark-gap switch for the same switching power. Indeed, a few thousand shots with peak current exceeding a mega-ampere and with hold-off voltage up to 20 kV have been conducted without showing measurable damage to the electrodes and insulators.

Choi, Sang H.↗

Development of a component centered fault monitoring and diagnosis knowledge based system for space power system

The overall approach currently being taken in the development of AMPERES (Autonomously Managed Power System Extendable Real-time Expert System), a knowledge-based expert system for fault monitoring and diagnosis of space power systems, is discussed. The system architecture, knowledge representation, and fault monitoring and diagnosis strategy are examined. A 'component-centered' approach developed in this project is described. Critical issues requiring further study are identified.

Lee, S. C.↗

On the need for space tests of plasma contactors as electron collectors

An analysis is presented of laboratory experiments that have shown that hollow plasma sources can provide low-impedance contact with a background plasma. In particular, some experiments show an report an 'ignited mode' of electron collection using plasma sources where almost an ampere was collected at a potential of 100 volts. The experimental results are compared with theoretical and computational models of plasma layers. Preliminary results indicate that the measured potential profiles and collected currents during the 'ignited mode' correspond to an increase in the background plasma thermal current of more than an order of magnitude. The results imply that the 'ignited mode' results are substantially impacted by the laboratory electron source and the tank size. Only experiments performed in space will be able to provide the correct boundary conditions for reliably testing high electron collection by plasma contactors.

Katz, Ira↗

A two-dimensional theory of plasma contactor clouds used in the ionosphere with an electrodynamic tether

Plasma contactors have been proposed as a means of making good electrical contact between biased surfaces such as found at the ends of an electrodynamic tether and the space environment. A plasma contactor is a plasma source which emits a plasma cloud which facilitates the electrical connection. The physics of this plasma cloud is investigated for contactors used as electron collectors and it is shown that contactor clouds in space will consist of a spherical core possibly containing a shock wave. Outside of the core the cloud will expand anisotropically across the magnetic field leading to a turbulent cigar shape structure along the field. This outer region is itself divided into two regions by the ion response to the electric field. A two-dimensional theory of the motion of the cloud across the magnetic field is developed. The current voltage characteristic of an Argon plasma contactor cloud is estimated for several ion currents in the range of 1-100 Amperes. It is shown that small ion current contactors are more efficient than large ion current contactors. This suggests that if a plasma contactor is used on an electrodynamic tether then a miltiple tether array will be more efficient than a single tether.

Hastings, D. E.↗

Portable High-Frequency Data-Acquisition System

Compact unit made of readily available solid-state components. Proposed system for acquisition of rapidly changing data self-contained and portable. Conceived for monitoring such aerodynamic effects as flutter, vibration, shock, sound, and pressure. Offers precise and fast acquisition of data and large data-storage capacity: has maximum sampling rate of 125 kHz, access time of 15 ns, and 1-million-bit memory. Measures time with "smart" (microprocessor-controlled) watch that maintains calendar time for more than 10 years without external power. Provides standby power from "smart" battery furnishing up to 1 ampere-hour of charge if power from main batteries lost.

Mustain, Roy W.↗

Requirements for long-life operation of inert gas hollow cathodes: Preliminary report

An experimental investigation was initiated to establish conditioning procedures for reliable hollow cathode operation via the characterization of critical parameters in a representative cathode test facility. From vacuum pumpdown rates, it was found that approximately 1.5 hours were required to achieve pressure levels within 5 percent of the lowest attainable pressure for this facility, depending on the purge conditions. The facility atmosphere was determined by a residual gas analyzer to be composed of primarily air and water vapor. The effects of vacuum pumping and inert gas purging were evaluated. A maximum effective leakage rate of 2.0 x 10(exp -3)sccm was observed and its probable causes were examined. An extended test of a 0.64 cm diameter Mo-Re hollow cathode was successfully completed. This test ran for 504 hours at an emission current of 23.0 amperes and a xenon flow rate of 6.1 sccm. Discharge voltage rose continuously from 15 to 21 volts over the course of the test. The temperature of the cathode body during the test was relatively stable at 1160 C. Post-test examination revealed ion-bombardment texturing of the orifice plate to be the only detectable sign of wear on the hollow cathode.

Verhey, Timothy R.↗

Data acquisition for a real time fault monitoring and diagnosis knowledge-based system for space power system

The design and implementation of the real-time data acquisition and processing system employed in the AMPERES project is described, including effective data structures for efficient storage and flexible manipulation of the data by the knowledge-based system (KBS), the interprocess communication mechanism required between the data acquisition system and the KBS, and the appropriate data acquisition protocols for collecting data from the sensors. Sensor data are categorized as critical or noncritical data on the basis of the inherent frequencies of the signals and the diagnostic requirements reflected in their values. The critical data set contains 30 analog values and 42 digital values and is collected every 10 ms. The noncritical data set contains 240 analog values and is collected every second. The collected critical and noncritical data are stored in separate circular buffers. Buffers are created in shared memory to enable other processes, i.e., the fault monitoring and diagnosis process and the user interface process, to freely access the data sets.

Wilhite, Larry D.↗

Requirements for long-life operation of inert gas hollow cathodes - Preliminary results

An experimental investigation was initiated to establish conditioning procedures for reliable hollow cathode operation via the characterization of critical parameters in a representative cathode test facility. From vacuum pumpdown rates, it was found that approximately 1.5 hours were required to achieve pressure levels within 5 percent of the lowest attainable pressure for this facility, depending on the purge conditions. The facility atmosphere was determined by a residual gas analyzer to be composed of primarily air and water vapor. The effects of vacuum pumping and inert gas purging were evaluated. A maximum effective leakage rate of 2.0 x 10 (exp -3) sccm was observed and its probable causes were examined. An extended test of a 0.64 cm diameter Mo-Re hollow cathode was successfully completed. This test ran for 504 hours at an emission current of 23.0 amperes and a xenon flow rate of 6.1 sccm. Discharge voltage rose continuously from 15 to 21 volts over the course of the test. The temperature of the cathode body during the test was relatively stable at 1160 C. Post-test examination revealed ion-bombardment texturing of the orifice plate to be the only detectable sign of wear on the hollow cathode.

Verhey, Timothy R.↗

Laboratory experiments on plasma contactors

Experimental results describing the operation of hollow cathode plasma contactors collecting and emitting electrons from and to an ambient plasma at current levels of the order of one ampere are presented. The voltage drops induced between a contactor and an ambient plasma are shown to be a few tens of volts at such current levels. The development of a double sheath and the production of substantial numbers of ions by electrons streaming across it are associated with the electron collection process. The development of a complex potential structure including a high potential hill just downstream of the cathode orifice is shown to characterize typical contactor emitting electrons.

Wilbur, Paul J.↗

Magnetic suspension and balance system advanced study, 1989 design

The objectives are to experimentally confirm several advanced design concepts on the Magnetic Suspension and Balance Systems (MSBS). The advanced design concepts were identified as potential improvements by Madison Magnetics, Inc. (MMI) during 1984 and 1985 studies of an MSBS utilizing 14 external superconductive coils and a superconductive solenoid in an airplane test model suspended in a wind tunnel. This study confirmed several advanced design concepts on magnetic suspension and balance systems. The 1989 MSBS redesign is based on the results of these experiments. Savings of up to 30 percent in supporting magnet ampere meters and 50 percent in energy stored over the 1985 design were achieved.

Boom, Roger W.↗

How to create ball lightning

Procedures are given on how to produce ball lightning. Necessary equipment includes a transformer of 150,000 watts capable of providing approximately 10,000 amperes at 15 volts, 60 cycles; thick one inch cables of stranded wire leading into a 3 by 4 by 1 foot plastic tank; a quarter inch thick 4 by 6 inch aluminum plate to be used as one of the discharge electrodes; and another electrode of heavy copper wire with the insulation stripped back 6 inches.

Golka, Robert K., Jr.↗

ARCFLO analysis for high-enthalpy arc heaters

Feasibility, physical constraints, and preliminary design and operating envelope are calculated for a next-generation segmented arc heater with enthalpies of 70-90 MJ/kg, for simulation of fast lunar or Martian return trajectories. The ARCFLO computer program is modified for improved accuracy in high-enthalpy radiation-dominated flows. The ARCFLO band-radiation model is compared with the state-of-the-art spectral-radiation code NEQAIR. The band-radiation model is corrected, and band-absorption coefficients are reduced by up to 40 percent at high temperatures. Parametric studies show that, with conventional wall-heating limitations, high mass flow and high enthalpy are contradictory design goals owing to the increase of radiation losses with pressure, current density, and constrictor diameter. With existing hardware limitations, an enthalpy of 70 MJ/kg with a flow rate of 0.1 kg/s can be achieved in a constrictor with 5-6 cm diameter operating near 3-atm stagnation pressure. The total power is under 100 MW, but the current is very high: 14,000-18,000 amperes.

Milos, Frank S.↗

Model of electron collecting plasma contactors

In laboratory experiments, plasma contactors are observed to collect ampere-level electron currents with low impedance. In order to extend the laboratory experience to the low-earth-orbit environment, a model of plasma contactors is being developed. Laboratory results are being used to support and validate the model development. The important physical processes observed in the laboratory are that the source plasma is separated from the background plasma by a double layer and that ionization of the expellant gas by the collected electrons creates the bulk of the ions that leave the source plasma. The model, which uses Poisson's equation with a physical charge density that includes the ion and electron components of both the source and the ambient plasmas, reproduces this phenomenon for typical experimental parameters. The calculations, in agreement with the laboratory results, show little convergence of the accelerated electrons. The angular momentum of the incoming electrons dramatically reduces the peak electron density. These electrons ionize enough gas to generate the source plasma. Calculations show that the increase in ionization rate with potential produces a steep rise in collected current with increasing potential as seen in the laboratory.

Davis, V. A.↗