Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “accelerated aging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

Impact of threading dislocation density on the lifetime of InAs quantum dot lasers on Si

We investigate the impact of threading dislocation density on the reliability of 1.3 μm InAs quantum dot lasers epitaxially grown on Si. A reduction in the threading dislocation density from 2.8 × 108 cm−2 to 7.3 × 106 cm−2 has improved the laser lifetime by about five orders of magnitude when aged continuous-wave near room temperature (35 °C). We have achieved extrapolated lifetimes (time to double initial threshold) more than 10 × 106 h. An accelerated laser aging test at an elevated temperature (60 °C) reveals that p-modulation doped quantum dot lasers on Si retain superior reliability over unintentionally doped ones. These results suggest that epitaxially grown quantum dot lasers could be a viable approach to realize a reliable, scalable, and efficient light source on Si.

Jung, Daehwan↗

Framework for Modelling Interface Degradation in Photovoltaic Modules at the Molecular Level

A significant challenge facing the solar industry is developing a reliable method to accurately predict photovoltaic module reliability over decades-long operating lifetimes. For the specific case of encapsulant adhesion-where interface delamination directly leads to reduced module efficiency- predictive models are critical for assessing long term reliability of new module materials over time frames conducive to research and development. We thus present a framework for modelling the temporal evolution of encapsulant adhesion by accounting for chemicaldegradation mechanisms at the molecular level. The model is developed though an unprecedented survey of encapsulant adhesion energy measurements from lab and field- aged modules with agingtimes spanning months to nearly three decades. Chemical analyses of new and aged EVA encapsulants are conducted to identify the dominant degradation mechanisms for modelling interface adhesion: deactivation, polymer chain scission, and hydrolytic polymerization. The strength of this framework is in the model's modularity, which renders it adaptable to any type of aging environment and encapsulation material.

14 SOLAR ENERGY↗

From Cell to System: Accelerated hpc Simulations of BESS Aging under Frequency Regulation and Arbitrage use cases

Lithium-ion battery energy storage systems (BESS) packs have emerged as a leading solution for grid-scale energy storage, enhancing resiliency and balancing load fluctuations. Yet, experimental characterization of large-format LIB packs-particularly to assess performance and degradation over hundreds of cycles - demands substantial hardware investment and multi-year testing campaigns. In this work, we couple a hierarchical, physics-based modeling framework agnostic to electrode chemistries with high-performance computing to accelerate systems level evaluation by upto two orders of magnitude. Building on the open-source liionpack platform, we implement cell, module, and pack-scale electrochemical models enriched with mechanistic aging mechanisms and deploy them on an HPC cluster to simulate 150−200kWh systems over 500 - 1,000 cycles with in days. We subject these virtual B ESS to both constant-current cycling and realistic grid service profiles spanning frequency regulation, ramp-rate support, and energy arbitrage-and quantify the resulting degradation patterns. Our results reveal that localized cell aging can induce substantial nonuniformity at module and pack levels, with service-specific cycling protocols driving distinct aging modes. This rapid, multiscale modeling approach provides a powerful design-space exploration tool for optimizing electrical architecture, control strategies, and operational schedules to prolong pack lifetime and lower total cost of ownership.

Ayalasomayajula, Surya [ORNL] (ORCID:0009000860788↗

Utilization of the Critic Subnetwork of a Generative Adversarial Network as Detector of Morphological Material Change in Image Data

The resolution of computed tomography (CT) has become high enough to monitor morphological changes due to aging in materials in long-term applications. For this work, we explored the utility of the critic of a generative adversarial network (GAN) to automatically detect such changes. The GAN was trained with images of pristine Pharmatose, which is used as a surrogate energetic material. It is important to note that images of the material with altered morphology were only used during the test phase. The GAN-generated images reproduced the microstructure of Pharmatose well, although some unrealistic particle fusion was seen. Calculated morphological metrics (volume fraction, interfacial line length, and local thickness) for the synthetic images also showed good agreement with the training data, albeit with signs of mode collapse in the interfacial line length. While the critic exposed changes in particle size, it showed limited ability to distinguish images by particle shape. The detection of shape differences was also a more challenging task for the selected morphological metrics that related to energetic material performance. We further tested the critic with images of aged Pharmatose. Subtle changes due to aging are difficult for the human analyst to detect; but both critic and morphological metrics analysis showed image differentiation.

36 MATERIALS SCIENCE↗

A Reconfigurable Planar Capacitor Sensor for Thru the Jacket Dielectric Constant Measurement of Cable Insulation

Planar capacitor sensors have been proposed to measure the aging-related dielectric constant variation of the jacket or insulation materials of cables. Although capacitor sensors have been used to monitor the aging of cable insulation by removing the jacket, through the jacket measurement of cable insulation dielectric constant variation is difficult because once the sensor is placed on the jacket it would either measure the aging of the jacket or that of the jacket and insulation together. A reconfigurable sensor along with innovative cable-specific models could be used to determine the jacket and insulation aging using the same sensor. For the proposed novel reconfigurable sensor, the electric field penetration depth is changed by activating and deactivating PIN diode switches. In one instance, the sensor measures the dielectric constant variation of the jacket, while in the next, it measures the dielectric constant variation of both the jacket and the insulation. Here, by leveraging previously developed capacitance estimation models from large-scale finite element simulations for a specific cable, these two sets of measurement data are used to evaluate the aging-related dielectric constant variation of the insulation. Experimental data from aged cable specimens are presented to demonstrate the operation of the sensor.

47 OTHER INSTRUMENTATION↗

Temperature Dependence of FDR Response for Thermally Aged Low-Voltage Cables

Frequency Domain Reflectometry (FDR) has attracted significant attention for use in nuclear power plants (NPPs) for non-destructive cable health monitoring. However, cable aging detection using FDR faces challenges due to its high sensitivity to environmental factors such as temperature, vibrations, proximity to other cables, and so on. This work aims to evaluate the influence of measurement temperature on the FDR reflected signal in a low voltage cable undergoing accelerated thermal aging. A 100 ft long multi-core low-voltage unshielded power cable insulated with flame retardant ethylene propylene rubber (FR-EPR) and covered by a chloro-polyethylene (CPE) jacket was selected for this study. The cable was energized during aging by a 480 VAC 3-phase motor, and a 30 ft mid-section of this cable was routed through an air circulating oven held at 140 °C for up to an effective aging time of 62 days. FDR measurements were taken periodically with the oven on (at 140 °C) and with the oven off (at 22 °C). A comparative analysis of data collected at both temperatures showed that the FDR response was strongly dependent on measurement temperature. FDR measurements at ambient temperature showed large peaks corresponding to impedance changes in the aged section of the cable after 3 days of aging. These peaks continued to rise steadily with increasing aging time. However, for measurements taken at 140 °C, slowly rising peaks in the oven region (aged section) were observed only after a lead time of 23 days of aging. This work highlights the importance of measurement temperature on the performance of FDR as a condition monitoring tool for aging cables.

Sriraman, Aishwarya↗

Bond Wire Damage Detection and SOH Estimation of a Dual Pack IGBT Power Module using Active Power Cycling and Reflectometry

High thermal and electrical stress, over a period of time tends to cause deterioration of the health of power electronic switches. A huge fraction of research efforts involves the study of power electronic device reliability and development of novel techniques with higher accuracy in health estimation of such devices. Until today, no other existing techniques can determine the number of lifted bond wires and their locations in a live IGBT module. Through this paper, a new method for online condition monitoring of IGBTs and IGBT modules using SSTDR has been proposed. Unlike traditional methods, this research work concentrates at the gate terminals of the device instead of looking at the collector side. In addition, the RL-equivalent circuit to represent a bond wire has been developed for the DUT and simulated in CST Studio Suite to measure the reflection amplitudes. Both the experimental and simulation results have been compared. These results prove that a single measurement is sufficient to predict the failure of the device instead of looking at the traditional precursor parameter. With only two sets of measurements, it is possible to locate the aged device inside a module and detect the number of bond wire lift offs associated to that device.

30 DIRECT ENERGY CONVERSION↗

Sequential versus Simultaneous Aging of EPDM Nuclear Cable Insulation Subjected to Elevated Temperature and Gamma Radiation

Electrical cables are integral to power, control, and instrumentation systems within nuclear power plants (NPPs). Exposure of cable systems within nuclear containment to elevated temperatures and gamma radiation during decades-long operation of NPPs can lead to degradation of cable polymeric insulation. Prediction of nuclear cable insulation degradation is complicated as thermal and radiation stress are not additive. In this work, we explore the relative effects of simultaneous and sequential thermal and gamma irradiation on the aging of ethylene-propylene-diene (EPDM) elastomer insulation to better understand realistic scenarios of cable insulation degradation. Cable insulation samples of EPDM were subjected to up to 320 kGy of gamma radiation at a dose rate of 300 Gy/hr in two heating scenarios: (1) simultaneously aged samples were heated at 150°C during irradiation and (2) sequentially aged samples were heated at 150°C for designated durations followed by corresponding periods of irradiation at ambient temperature. The mass, tensile elongation at break, and carbonyl index were assessed to quantify aging of the polymers. The simultaneous aging scenario was found to the more severe of the two for EPDM insulation degradation.

ethylene-propylene-diene elastomer, EPDM, nuclear ↗

Independence of Environmental and Mechanical Damages on Silicone Adhesive Stored in a Thermo-Oxidative Environment

Abstract Elastomeric polymer materials hold a special place in today’s industrial sectors with respect to structural application needs. Low quality materials are detrimental to industries like aerospace, and automotive engineering. Assessment of the durability of elastomers for structural applications has been of much interest among the literary circles for decades and new materials keep outperforming the existing ones. Polymeric adhesives are one of the most abundantly used materials in these industries. All polymeric materials get damaged when in contact with aggressive environments in presence of high temperature and oxygen. Commonly referred to as thermo-oxidation, this environment exposes the material to heat and oxidation reactions in presence of oxygen. Resultantly, during service life, the damage to the polymer matrix is primarily caused by two factors: mechanical damage and environmental aging. Environmental aging is an irreversible phenomenon caused by changes in the molecular structure while mechanical damage maintains the shape of the polymer matrix, and the deterioration is mostly due to polymer chain mobility. Environmental aging can be caused by a single environmental agent or by a synergized impact of several environmental elements. Increasing temperature is found to be proportional to decreasing tensile strength and toughness of material. The rate and extent of degradation can be accessed by scrutinizing the changes in constitutive behavior of material through mechanical and chemical properties. Accelerated thermal aging is among the most common modes of process related degradation, leading generally to chain scission, and crosslinking phenomena and reduced resistance to fracture stress, and strain. In this experimental study, our goal is to separate the environmental degradation from mechanical damage. A silicone-based adhesive was aged in thermo-oxidative at (0%RH) aging environment. The damage and decay mechanisms have been used to draw a distinction between environmental degradation and mechanical damage. Material characterization included uniaxial tensile test (failure and cyclic) and scanning electron microscopy (SEM) tests on as-received and aged samples. Aging was conducted at three different temperatures (60°C, 80°C and 95°C) and six different exposure durations (1, 3, 10, 30, 90 and 200 days). This work confirms that environmental damage is superposed on top of the mechanical damage, and thus, they are separable. The total mechanical and environmental damage is a synergized effect of all exposure conditions and parameters involved i.e., aging time, temperature, and oxygen. The chemistry and mechanics of the polymer degradation were found to be in good agreement with each other.

Alazhary, Sharif↗

Effect of Filler Concentration on Thermal Stability of Vinyl Copolymer Elastomer (VCE) Composites

To study the thermal stability of vinyl copolymer elastomer (VCE) in its composite form, systematic TGA characterizations were conducted in both nonisothermal and isothermal modes. The effects of filler concentration on the aging behaviors of the VCE/filler composites were investigated under nitroplasticizer (NP) environment. FTIR characterization was used to probe the structural changes in the VCE polymer before and after the thermal treatments. This study suggests that the filler concentration significantly deteriorates the thermal stability of NP at a moderate temperature (< 70 °C). The degradation of NP, in turn, accelerates the aging process of the VCE polymer in its composite form.

36 MATERIALS SCIENCE↗

Nondestructive Characterization and Accelerated UV Testing of Browned Field-Aged PV Modules

Encapsulant browning is one of the most common degradation modes found in crystalline silicon field-aged photovoltaic modules. Browning, usually undetected unless severe, reduces the short-circuit current (Isc) produced by a module. Therefore, field-aged browned modules have been subjected to accelerated UV testing to obtain true end-of-life activation energy for the encapsulant browning mechanism. A novel time- and resource-saving accelerated UV exposure testing method simultaneously allowing multiple module temperatures to be maintained in a single chamber run is presented. Six field-aged crystalline silicon modules of glass/backsheet construction (three each from BP Solar/Solarex MSX 60 and Siemens M55) with similar glass and encapsulant formulation were exposed to a UV dosage of 450 kWh/m2 . Through passive heating, the average module temperatures for the BP Solar/Solarex modules were 60 degrees C, 77 degrees C, and 85 degrees C and those of Siemens M55 were 75 degrees C, 80 degrees C, and 837 degrees C. To study UV browning, the modules were intermittently characterized through visual imaging, UV fluorescence imaging, electroluminescence imaging, quantum efficiency measurements, module, and cell-level light I-V measurements. An Isc decrease corroborated the increased extent of browning with increased module temperature. For the BP Solar/Solarex modules, the Low T, Mid T, and the High T modules showed a 1.37%, 2.48%, and 3.26% Isc drop, respectively. The Siemens modules showed a 4.11%, 5.65%, and 6.95% Isc drop. The multiple cell-level Isc data points obtained for each module temperature increased provided statistical significance. Activation energy for encapsulant browning was calculated as 0.44 and 0.72 eV for MSX 60 and M55 modules, respectively.

14 SOLAR ENERGY↗

The Dual-Axis Radiographic Hydrodynamic Test Facility Capability Expansion (DCX) Strategy

The Dual-Axis Radiographic Hydrodynamic Test (DARHT) facility is a vital and important part of the Nation’s nuclear security enterprise. With more than two decades of operations, DARHT has a storied history. Conceived in the 1970s, constructed in the 1990s, and operational since 2000, DARHT has advanced from open-air hydrodynamic experiments (hydros) to foam-confined hydros, to vessel-confined hydros, and in 2022, the 75th hydro was successfully completed. Radiography has advanced from a single-axis, single-pulse system to a dual-axis, multi-pulse capability to variable fields of view (VFV) on both accelerators. The culmination of these experiences, accomplishments, and advancements has brought us to a very important question: What do the next two decades at DARHT look like? The world is not the same place it was in the 1990s when construction at DARHT was in progress. Evolving threats, an expanding mission, and technology changes necessitate adaptation. To adapt, the aging facility, accelerators, vessels, and detector systems require improvements to ensure DARHT remains the Nation’s hydrodynamic data foundation for stockpile certification, safety, surety, and global security threats.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Topological analysis of X-ray CT data for the recognition and trending of subtle changes in microstructure under material aging

X-ray computed tomography (CT) is an established non-destructive tool for 3D imaging of multiphasic composites. Numerous applications of X-ray CT in medical diagnosis and materials characterization have been reported, many involving field-specific innovations in the imaging technology itself. Yet, quantitative summarization to link image features to properties of interest has been rare. Here we address this issue by employing state-of-the-art technics in scalar field topology for the summarization of X-ray CT images of an example biphasic system. By varying processing-parameters we create different microstructures, evolve them through accelerated thermal aging, CT-image them pre- and post-aged, and demonstrate the ability of our image summarization method to systematically track process- and age-related changes, which can often be very subtle. A novel aspect of the algorithm involves recognition over multiple resolution levels, which provides deeper insight into the pattern relationship between grain-like features and their neighbors. The method is general, adaptable to diverse image reconstruction methods and materials systems, and particularly useful in applications where practical constraints on the sample-size limits the reliable use of more complex models, e.g., convolutional neural networks.

36 MATERIALS SCIENCE↗

Durability of ionomer encapsulants in photovoltaic modules

Ethylene vinyl acetate (EVA) has for decades been the preferred material for photovoltaic (PV) module encapsulation. However, while it is relatively inexpensive and initially adheres well to module components, EVA discolors with age and - as interfacial adhesion degrades - becomes susceptible to delamination, ultimately resulting in reduced module efficiency and shortened service lifetimes. As potential replacements for EVA, ionomer thermoplastic materials cure faster, are more resistant to discoloration and potential induced degradation, and do not evolve corrosive acetic acid, making them compatible with new device materials such as perovskites. Since there is limited information on ionomer durability for PV module applications, a series of field and accelerated laboratory aging studies were conducted to assess ionomer interface stability in the presence of terrestrial environmental stressors. It is shown that adhesion to the glass and cell interfaces of PV modules is inferior to EVA, both before and after aging, rendering ionomers particularly susceptible to delamination after short timeframes. Potential solutions to improve ionomer adhesion are discussed.

14 SOLAR ENERGY↗

The Dual-Axis Radiographic Hydrodynamic Test Facility Capability eXpansion (DCX) Strategy

The Dual-Axis Radiographic Hydrodynamic Test (DARHT) facility is a vital and important part of the Nation’s nuclear security enterprise. The Department of Energy/National Nuclear Security Administration (DOE/ NNSA) Stockpile Stewardship Management Plan (SSMP) identifies DARHT as a weapons mission critical facility along with the need to modernize DARHT to support weapons modernization efforts. With more than two decades of operations, DARHT has a storied history. Conceived in the 1970s, constructed in the 1990s, and operational since 2000, DARHT has advanced from open-air hydrodynamic experiments (hydros) to foam-confined hydros, to vessel-confined hydros, and in 2022, the 75 th hydro was successfully completed. Radiography has advanced from a single-axis, single-pulse system to a dual-axis, multi-pulse capability to variable fields of view (VFV) on both accelerators. The culmination of these experiences, accomplishments, and advancements has brought us to a very important question: What do the next two decades at DARHT look like? The world is not the same place it was in the 1990s when construction at DARHT was in progress. Evolving threats, an expanding mission, and technology changes necessitate adaptation. The 2018 Nuclear Posture Review (NPR) states that the nuclear weapons infrastructure has suffered the effects of age and underfunding with no margin for further delay in recapitalizing the physical infrastructure. To adapt, the aging facility, accelerators, vessels, and detector systems require improvements to ensure DARHT remains the Nation’s hydrodynamic data foundation for stockpile certification, safety, surety, and global security threats.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Femoral Head Bone Loss Following Short and Long-Duration Spaceflight

Exposure to mechanical unloading during spaceflight is known to have significant effects on the musculoskeletal system. Our ongoing studies with the mouse bone model have identified the failure of normal stem cell-based tissue regeneration, in addition to tissue degeneration, as a significant concern for long-duration spaceflight, especially in the mesenchymal and hematopoietic tissue lineages. The 30-day BionM1 and the 37-day Rodent Research 1 (RR1) missions enabled the possibility of studying these effects in long-duration microgravity experiments. We hypothesized that the inhibition of stem cell-based tissue regeneration in short-duration spaceflight would continue during long-duration spaceflight and furthermore would result in significant tissue alterations. MicroCT analysis of BionM1 femurs revealed 31% decrease in bone volume ratio, a 14% decrease in trabecular thickness, and a 20% decrease in trabecular number in the femoral head of space-flown mice. Furthermore, high-resolution MicroCT and immunohistochemical analysis of spaceflight tissues revealed a severe disruption of the epiphyseal boundary, resulting in endochondral ossification of the femoral head and perforation of articular cartilage by bone. This suggests that spaceflight in microgravity may cause rapid induction of an aging-like phenotype with signs of osteoarthritic disease in the hip joint. However, mice from RR1 exhibited significant bone loss in the femoral head but did not exhibit the severe aging and disease-like phenotype observed during BionM1.This may be due to increased physical activity in the RH hardware. Immunohistochemical analysis of the epiphyseal plate and investigation of cellular proliferation and differentiation pathways within the marrow compartment and whole bone tissue is currently being conducted to determine alterations in stem cell-based tissue regeneration between these experiments. Our results show that the observed inhibition of stem cell-based tissue regeneration persists during long-duration spaceflight. Furthermore, spaceflight femurs from BionM1 indicate onset of an accelerated aging-like phenotype with signs of osteoarthritic disease shown by disruption of the epiphyseal boundary and endochondral ossification. These effects are likely caused by a failure of stem cells to regenerate degraded tissues and may have significant implications for bone and cartilage health following extensive periods of mechanical unloading during long-duration spaceflight.

microgravity↗

Femoral Head Bone Loss Following Short and Long-Duration Spaceflight

Exposure to mechanical unloading during spaceflight is known to have significant effects on the musculoskeletal system. Our ongoing studies with the mouse bone model have identified the failure of normal stem cell-based tissue regeneration, in addition to tissue degeneration, as a significant concern for long-duration spaceflight, especially in the mesenchymal and hematopoietic tissue lineages. The 30-day BionM1 and the 37-day Rodent Research 1 (RR1) missions enabled the possibility of studying these effects in long-duration microgravity experiments. We hypothesized that the inhibition of stem cell-based tissue regeneration in short-duration spaceflight would continue during long-duration spaceflight and furthermore would result in significant tissue alterations. MicroCT analysis of BionM1 femurs revealed 31 decrease in bone volume ratio, a 14 decrease in trabecular thickness, and a 20 decrease in trabecular number in the femoral head of space-flown mice. Furthermore, high-resolution MicroCT and immunohistochemical analysis of spaceflight tissues revealed a severe disruption of the epiphyseal boundary, resulting in endochondral ossification of the femoral head and perforation of articular cartilage by bone. This suggests that spaceflight in microgravity may cause rapid induction of an aging-like phenotype with signs of osteoarthritic disease in the hip joint. However, mice from RR1 exhibited significant bone loss in the femoral head but did not exhibit the severe aging and disease-like phenotype observed during BionM1. This may be due to increased physical activity in the RH hardware. Immunohistochemical analysis of the epiphyseal plate and investigation of cellular proliferation and differentiation pathways within the marrow compartment and whole bone tissue is currently being conducted to determine alterations in stem cell-based tissue regeneration between these experiments. Our results show that the observed inhibition of stem cell-based tissue regeneration persists during long-duration spaceflight. Furthermore, spaceflight femurs from BionM1 indicate onset of an accelerated aging-like phenotype with signs of osteoarthritic disease shown by disruption of the epiphyseal boundary and endochondral ossification. These effects are likely caused by a failure of stem cells to regenerate degraded tissues and may have significant implications for bone and cartilage health following extensive periods of mechanical unloading during long-duration spaceflight.

stem cells↗