Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “WIRES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

A Thermal Analysis of a Hot-Wire Probe for Icing Applications

This paper presents a steady-state thermal model of a hot-wire instrument applicable to atmospheric measurement of water content in clouds. In this application, the power required to maintain the wire at a given temperature is used to deduce the water content of the cloud. The model considers electrical resistive heating, axial conduction, convection to the flow, radiation to the surroundings, as well as energy loss due to the heating, melting, and evaporation of impinging liquid and or ice. All of these parameters can be varied axially along the wire. The model further introduces a parameter called the evaporation potential which locally gauges the maximum fraction of incoming water that evaporates. The primary outputs of the model are the steady-state power required to maintain a spatially-average constant temperature as well as the variation of that temperature and other parameters along the wire. The model is used to understand the sensitivity of the hot-wire performance to various flow and boundary conditions including a detailed comparison of dry air and wet (i.e. cloud-on) conditions. The steady-state power values are compared to experimental results from a Science Engineering Associates (SEA) Multi-Element probe, a commonly used water-content measurement instrument. The model results show good agreement with experiment for both dry and cloud-on conditions with liquid water content. For ice, the experimental measurements under read the actual water content due to incomplete evaporation and splashing. Model results, which account for incomplete evaporation, are still higher than experimental results where the discrepancy is attributed to splashing mass-loss which is not accounted in the model.

Thermal Analysis↗

Ultrasonic Device for Assessing the Quality of a Wire Crimp

A system for determining the quality of an electrical wire crimp between a wire and ferrule includes an ultrasonically equipped crimp tool (UECT) configured to transmit an ultrasonic acoustic wave through a wire and ferrule, and a signal processor in communication with the UECT. The signal processor includes a signal transmitting module configured to transmit the ultrasonic acoustic wave via an ultrasonic transducer, signal receiving module configured to receive the ultrasonic acoustic wave after it passes through the wire and ferrule, and a signal analysis module configured to identify signal differences between the ultrasonic waves. The signal analysis module is then configured to compare the signal differences attributable to the wire crimp to a baseline, and to provide an output signal if the signal differences deviate from the baseline.

Yost, William T.↗

Fine-Filament MgB2 Superconductor Wire

Hyper Tech Research, Inc., has developed fine-filament magnesium diboride (MgB2) superconductor wire for motors and generators used in turboelectric aircraft propulsion systems. In Phase I of the project, Hyper Tech demonstrated that MgB2 multifilament wires (<10 micrometers) could reduce alternating current (AC) losses that occur due to hysteresis, eddy currents, and coupling losses. The company refined a manufacturing method that incorporates a magnesium-infiltration process and provides a tenfold enhancement in critical current density over wire made by a conventional method involving magnesium-boron powder mixtures. Hyper Tech also improved its wire-drawing capability to fabricate fine multifilament strands. In Phase II, the company developed, manufactured, and tested the wire for superconductor and engineering current density and AC losses. Hyper Tech also fabricated MgB2 rotor coil packs for a superconducting generator. The ultimate goal is to enable low-cost, round, lightweight, low-AC-loss superconductors for motor and generator stator coils operating at 25 K in next-generation turboelectric aircraft propulsion systems.

Cantu, Sherrie↗

Short Circuiting the Controller –Missteps in Maintenance and Inspection of Process and Wiring in STS-93

During the launch of the Chandra X-Ray Observatory in 1999, an in-flight anomaly occurred a few seconds after liftoff. A power fluctuation caused two Main Engine controllers to drop offline. Fortunately, due to redundancy, the Space Shuttle Columbia was able to successfully reach orbit and avoid an abort. After the successful deployment of Chandra and the safe return of the crew, in-vestigation revealed that the controller failure was due to a wire short in the pay-load bay. It was suspected that the Kapton insulation on the wire rubbed off against a burred screw head, the result of overtightening of the screw during a maintenance event 4 to 5 years prior to the STS-93 mission. Vibrations led the abraded wire to short during flight. The Space Shuttle Program was grounded for 4 months while a program-wide inspection and wire chafing mitigation effort of all orbiter wiring ensued.

Kristy S Yun↗

Preliminary Measurements of Partial Discharge Inception Voltage Degradation with Constant Temperature Aging of Magnet Wire Twisted Pairs for Electric Aircraft Motors

Electric aircraft require high reliability electric motors to meet the stringent safety standards of the aviation industry. Motor winding insulation lifetime and reliability models for electric aircraft applications are needed to enable design of high reliability and high-performance electric motors for aviation applications. Three primary stresses effect the lifetime of motor winding insulation: thermochemical, mechanical, and electrical. This paper presents preliminary experiments on twisted pairs of magnet wire targeting understanding the thermo-chemical degradation of motor winding insulation through constant temperature thermal aging. Three types of magnet wire twisted pairs where tested: polyimide insulated magnet wire, epoxy coated polyimide insulated magnet wire, and epoxy potted polyimide magnet wire. The degradation of the samples over time at temperature was tracked using partial discharge inception voltage measurements. These initial experiments were used for development of procedures and expertise in partial discharge testing and thermo-chemical aging to inform future testing. The preliminary nature of these experiments should be noted when viewing the results. Lessons learned from the experiments are documented.

Thomas Tallerico↗

Processing a printed wiring board by single bath electrodeposition

A method of processing a printed wiring board. Initial processing steps are implemented on the printed wiring board. Copper is plated on the printed wiring board from a bath containing nickel and copper. Nickel is plated on the printed wiring board from a bath containing nickel and copper and final processing steps are implemented on the printed wiring board.

Meltzer, Michael P↗

Comprehensive analysis of radiative properties of brass and Al arranged in nested cylindrical wire arrays.

Experimental results of nested cylindrical wire arrays (NCWA) consisting of brass (70% Cu and 30% Zn) wires on one array and Al (5056, 5% Mg) wires on the other array performed on the UNR Zebra generator at 1.0 MA current are compared and analyzed. Specifically, radiative properties of K-shell Al and Mg ions and L-shell Cu and Zn ions are compared as functions of the placements of the brass and Al wires on the inner and outer arrays. A full diagnostic set which included more than ten different beam-lines was implemented. Identical loads were fielded to allow the timing of time-gated pinhole and x-ray spectrometers to be shifted to get a more complete understanding of the evolution of plasma parameters over the x-ray pulse. The importance of the study of NCWAs with different wire materials is discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A Wire Position Monitor System for the 1.3 FHZ Tesla-Style Cryomodule at the Fermilab New-Muon-Lab Accelerator

The first cryomodule for the beam test facility at the Fermilab New-Muon-Lab building is currently under RF commissioning. Among other diagnostics systems, the transverse position of the helium gas return pipe with the connected 1.3 GHz SRF accelerating cavities is measured along the {approx}15 m long module using a stretched-wire position monitoring system. An overview of the wire position monitor system technology is given, along with preliminary results taken at the initial module cooldown, and during further testing. As the measurement system offers a high resolution, we also discuss options for use as a vibration detector. An electron beam test facility, based on superconducting RF (SRF) TESLA-style cryomodules is currently under construction at the Fermilab New-Muon-Lab (NML) building. The first, so-called type III+, cryomodule (CM-1), equipped with eight 1.3 GHz nine-cell accelerating cavities was recently cooled down to 2 K, and is currently under RF conditioning. The transverse alignment of the cavity string within the cryomodule is crucial for minimizing transverse kick and beam break-up effects, generated by the high-order dipole modes of misaligned accelerating structures. An optimum alignment can only be guaranteed during the assembly of the cavity string, i.e. at room temperatures. The final position of the cavities after cooldown is uncontrollable, and therefore unknown. A wire position monitoring system (WPM) can help to understand the transverse motion of the cavities during cooldown, their final location and the long term position stability after cryo-temperatures are settled, as well as the position reproducibility for several cold-warm cycles. It also may serve as vibration sensor, as the wire acts as a high-Q resonant detector for mechanical vibrations in the low-audio frequency range. The WPM system consists out of a stretched-wire position detection system, provided with help of INFN-Milano and DESY Hamburg, and RF generation and read-out electronics, developed at Fermilab.

43 PARTICLE ACCELERATORS↗

Transverse Beam Halo Measurements at High Intensity Neutrino Source (HINS) using Vibrating Wire Monitor

The measurement and control of beam halos will be critical for the applications of future high-intensity hadron linacs. In particular, beam profile monitors require a very high dynamic range when used for the transverse beam halo measurements. In this study, the Vibrating Wire Monitor (VWM) with aperture 60 mm was installed at the High Intensity Neutrino Source (HINS) front-end to measure the transverse beam halo. A vibrating wire is excited at its resonance frequency with the help of a magnetic feedback loop, and the vibrating and sensitive wires are connected through a balanced arm. The sensitive wire is moved into the beam halo region by a stepper motor controlled translational stage. We study the feasibility of the vibrating wire for the transverse beam halo measurements in the low-energy front-end of the proton linac.

43 PARTICLE ACCELERATORS↗

Method of fabricating high-density hermetic electrical feedthroughs using insulated wire bundles

A method of fabricating electrical feedthroughs coats of a plurality of electrically conductive wires with an electrically insulating material and bundles the coated wires together in a substantially parallel arrangement. The bundled coated wires are secured to each other by joining the electrically insulating material of adjacent wires together to form a monolithic block which is then cut transverse to the wires to produce a block section having opposing first and second sides with a plurality of electrically conductive feedthroughs extending between them.

36 MATERIALS SCIENCE↗

Structures of and methods for forming vertically aligned Si wire arrays

A structure consisting of vertically aligned wire arrays on a Si substrate and a method for producing such wire arrays. The wire arrays are fabricated and positioned on a substrate with an orientation and density particularly adapted for conversion of received light to energy. A patterned oxide layer is used to provide for wire arrays that exhibit narrow diameter and length distribution and provide for controlled wire position.

Kayes, Brendan M.↗

System and method for liquid crystal display system incorporating wire grid polarizers for large scale and large volume stereolithography

The present disclosure relates to a liquid crystal display (LCD) system. The system in one example has a light source for generating unpolarized light, and an LCD screen arranged in a path of transmittance of the unpolarized light. First and second wire grid polarizers are arranged adjacent to the LCD screen and each have a plurality of nano-scale wires, with the first and second wire grid polarizers have differing polarizations. A pitch of each of the nano-scale wires is no larger than one-third a wavelength of the unpolarized light from the light source. The wire grid polarizers create, in connection with operation of the LCD screen, a 2D light mask suitable for initiating the polymerization of an optically curable material.

Duoss, Eric B.↗

Superconducting wires for quench detection

A superconducting device includes a first superconducting wire configured to carry a first current in a superconducting state, and to generate thermal energy upon occurrence of a hot spot during conduction. The device includes a second superconducting wire, thermally coupled to and electrically isolated from the first superconducting wire. The second superconducting wire is configured to conduct a second current in a superconducting state below, but sufficiently near its critical surface to be quenched to a non-superconducting state upon conduction of the thermal energy from the first superconducting wire.

Van Der Laan, Daniel Cornelis↗

Modernizing the Legacy Fission Wire Measurement System for the Advanced Test Reactor-Critical Facility

Operational lifetime extensions of existing research reactors have emphasized the need for refurbishment, replacements, and upgrades to supporting equipment and instrumentation. The Advanced Test Reactor (ATR) at Idaho National Laboratory (INL), which entered service in 1967, has recently completed the sixth core internals change-out and has scheduled operations until at least 2040. Reactor maintenance and operational risk management is critically important in the research reactor community, however supporting measurement systems sometimes get overlooked when maintenance is planned. The Fission Wire Measurement System (FWMS) is a custom measurement system designed in the 1960s to measure the beta-particle activity of irradiated uranium-aluminum fission wires. This measurement is conducted to determine the fission rate profile of the Advanced Reactor Test Critical (ATR-C) facility. The ATR-C is an open-pool, low-power test reactor that was purpose driven to resemble ATR and is used to qualify experiment configurations and verify core models prior to full-power experiment irradiations in ATR. A power distribution measurement in ATR-C uses uranium-aluminum wires that are distributed throughout the ATR-C core to validate simulation and modeling results. These measurements require 340 to 1500 wires to be irradiated and measured within a 12-hour window. The activity of the wires is measured in the required time with the FWMS, which was put into service in 1965 at the Radiation Measurements Laboratory (RML). The system consists of 4 measurement channels and one reference channel, each with a 2-pi proportional gas flow detector and the measurement channels each have an automated sample changer. This legacy system is crucial to the continued operations of ATR and has undergone some minor hardware upgrades since 1965, however the system presently relies on custom control boards, custom gas ion chambers, analog amplifiers/discriminators, and a user interface (UI) for the system written in outdated code. Much of the equipment and software is custom with no commercial replacements or support and limited documentation. The existing control software requires an operating system that is no longer supported, creating more vulnerabilities to continued operations. A project is underway with a third-party vendor to design, build, and document a new control and data acquisition system (CDAS) for the FWMS. The new upgrade will replace the control system, computer, UI, sample changer motors, and main power supply while maintaining the interface with existing detector hardware. The upgraded system will be operated in parallel with the current hardware and software to conduct validation testing. This equipment upgrade demonstrates the commitment at ATR to ensuring successful operations and potential future research reactors at INL.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Bow shocks in ablated plasma streams for nested wire array z-pinches: A laboratory astrophysics testbed for radiatively cooled shocks

Astrophysical observations have demonstrated many examples of bow shocks, for example, the head of protostellar jets or supernova remnants passing through the interstellar medium or between discrete clumps in jets. For such systems where supersonic and super-Alfvenic flows and radiative cooling are all important, carefully scaled laboratory experiments can add insight into the physical processes involved. The early stage of a wire array z-pinch implosion consists of the steady ablation of material from fine metallic wires. Ablated material is accelerated toward the array axis by the JxB force. This flow is highly supersonic (M>5) and becomes super-Alfvenic (M{sub A}>2). Radiative cooling is significant in this flow and can be controlled by varying the material in the ablated plasma. The introduction of wires as obstructions in this steady flow leads to the formation of bow shocks, which can be used as a laboratory testbed for astrophysical bow shocks. The magnetic field associated with this obstruction wire can be controlled by varying the current through it. Differences in the shock for different cooling rates and different magnetic fields associated with the obstruction will be discussed, along with comparisons of dimensionless parameters in the experiments to astrophysical systems.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

EFFECTS OF SINTERING TEMPERATURE ON SUPERCONDUCTIVITY IN Ti-SHEATHED MgB{sub 2} WIRES

The effects of sintering temperature on the superconducting properties of Ti-sheathed MgB{sub 2} wires have been studied. The wires were fabricated by in situ powder-in-tube (PIT) method and characterized by x-ray diffraction, magnetization, scanning electron microscopy and transport measurements. Samples were sintered for 30 minutes at the following temperatures: 650 deg. C, 700 deg. C, 750 deg. C, 800 deg. C, and 850 deg. C. It is found that the cores of these wires are almost in pure MgB{sub 2} superconducting phase, indicating that the Ti-sheath does not react with Mg or B. The superconducting transition temperature T{sub c} decreases from 36 K to 34.2 K with the decrease of the sintering temperature from 850 deg. C to 650 deg. C. At 5 K and 20 K, critical current density J{sub c} peaks up for samples sintered at 800 deg. C, which is in sharp contrast with previously reported result that for Fe-sheathed MgB{sub 2} wires, J{sub c} peaks up at sintering temperature of 650 deg. C.

36 MATERIALS SCIENCE↗

An experimental investigation of the effectiveness of Ar-CO 2 shielding gas mixture for the wire arc additive process

Wire arc additive manufacturing (AM) is the process by which a large, metallic structure is built layer-by-layer using a welding arc to melt a wire feedstock. A novel opportunity exists to alter the shielding gas composition to fabricate distinct geometrical features without altering the other AM parameters. In this paper, shielding gases with varied concentrations of Argon (Ar) and CO 2 was used to deposit three distinct geometric shapes (walls, infill, and overhang) using a wire-based additive manufacturing system utilizing the gas metal arc welding (GMAW) surface tension transfer (STT) process. Computer-aided design (CAD) models were sliced with a custom-built slicer, and the sliced algorithm was converted into optimal robotic toolpaths. A custom virtual instrument (VI) was built in LabVIEW to compare the temperature profiles on the surface during each deposition process. After each deposition, the geometric features were scanned, and the surface waviness value was evaluated. Tensile and Charpy impact coupons were extracted from the wall geometries in the longitudinal and transverse directions and tested. The results indicated that a higher CO 2 content produced higher melt pool temperatures to an extent, while lower contents of CO 2 resulted in a dimensionally accurate geometry. The data also indicated that the 2%/98% CO 2 /Ar blend produced scatter in tensile strength and the analysis of variance (ANOVA) shows significant difference. However, the intermediate range of CO 2 (5–10%) resulted in uniform tensile properties. Altogether, these results indicate that a 5%/95% CO 2 /Ar blend is the ideal shielding gas for lowering process temperatures and improving mechanical properties in wire arc additive manufacturing using the gas metal arc welding surface tension transfer process. Additionally, varying concentrations of Ar/CO 2 can be used within the same part in order to modify the local properties or process parameters such as strength, toughness, temperature, or dimensional features. This may improve overall manufacturing quality without sacrificing specific properties.

42 ENGINEERING↗

Entrapment of Guide Wire in an Inferior Vena Cava Filter: A Technique for Removal

Entrapment of a central venous catheter (CVC) guide wire in an inferior vena cava (IVC) filter is a rare, but reported complication during CVC placement. With the increasing use of vena cava filters (VCFs), this number will most likely continue to grow. The consequences of this complication can be serious, as continued traction upon the guide wire may result in filter dislodgement and migration, filter fracture, or injury to the IVC. We describe a case in which a J-tipped guide wire introduced through a left subclavian access without fluoroscopic guidance during CVC placement was entrapped at the apex of an IVC filter. We describe a technique that we used successfully in removing the entrapped wire through the left subclavian access site. We also present simple useful recommendations to prevent this complication.

62 RADIOLOGY AND NUCLEAR MEDICINE↗