Error and Uncertainty Quantification in the Numerical Simulation of Complex Fluid Flows

The failure of numerical simulation to predict physical reality is often a direct consequence of the compounding effects of numerical error arising from finite-dimensional approximation and physical model uncertainty resulting from inexact knowledge and/or statistical representation. In this topical lecture, we briefly review systematic theories for quantifying numerical errors and restricted forms of model uncertainty occurring in simulations of fluid flow. A goal of this lecture is to elucidate both positive and negative aspects of applying these theories to practical fluid flow problems. Finite-element and finite-volume calculations of subsonic and hypersonic fluid flow are presented to contrast the differing roles of numerical error and model uncertainty. for these problems.

Barth, Timothy J.↗

On the mixture flow problem in lubrication of hydrodynamic bearings - Small solid volume fraction

The lubrication problem of infinitely long slider bearings with a mixture of fluid and particulate solid at small volume fraction level is studied. Closed-form analytical solutions for pressure and shear stress are obtained for a class of solid aggregates. The results reduce to those of pure fluid in the limiting case. A parametric study of the bearing performance with particulate solid is presented.

Khonsari, M. M.↗

The risk of renal stone formation during and after long duration space flight

BACKGROUND: The formation of a renal stone during space flight may have serious negative effects on the health of the crewmember and the success of the mission. Urinary biochemical factors and the influence of dietary factors associated with renal stone development were assessed during long duration Mir Space Station missions. METHODS: Twenty-four-hour urine samples were collected prior to, during and following long duration space flight. The relative urinary supersaturation of calcium oxalate, calcium phosphate (brushite), sodium urate, struvite and uric acid were determined. RESULTS: Changes in the urinary biochemistry of crewmembers during long duration spaceflight demonstrated increases in the supersaturation of the stone-forming salts. In-flight hypercalciuria was evident in a number of individual crewmembers and 24-hour dietary fluid intake and urine volume were significantly lower. During flight, there was a significant increase in brushite supersaturation. CONCLUSIONS: These data suggest acute effects of space flight and postflight changes in the urinary biochemistry favoring increased crystallization in the urine. The effects of dietary intake, especially fluid intake, may have a significant impact on the potential for renal stone formation. Efforts are now underway to assess the efficacy of a countermeasure to mitigate the increased risk.

manned↗

Recovery after exercise in the heat--factors influencing fluid intake

The restoration of body fluid balance following dehydration induced by exercise will occur through regulatory responses which stimulate ingestion of water and sodium ions. A number of different afferent signalling systems are necessary to generate appropriate thirst or sodium appetite. The primary sensory information of naturally occurring thirst is derived from receptors sensing cell volume and the volume of the extracellular fluid compartment. Sensory information from the oropharyngeal region is also an important determinant of thirst. The interaction of these various afferent signalling systems within the central nervous system determines the extent of fluid replacement following dehydration.

Non-NASA Center↗

Changes in leg volume during microgravity simulation

Little published information exists regarding the magnitude and time course of cephalad fluid shift resulting from microgravity simulations. Six subjects were exposed to 150 min each at horizontal bed rest, 6-deg head-down tilt, and horizontal water immersion. Fluid shift was estimated by calculating leg volumes from eight serial girth measurements from groin to ankle before, during, and after exposure. Results were compared with data from the first 3 h of spacecraft. By the end of exposure, total leg volume for the six subjects decreased by 2.6 +/- 0.8 percent, 1.7 +/- 1.2 percent, and 4.0 +/- 1.6 percent for horizontal, head-down, and immersion, respectively. Changes had plateaued for horizontal and head-down and had slowed for immersion. Relatively more fluid was lost from the lower leg than the thigh for all three conditions, particularly head-down. During the first 3 h of spaceflight, total leg volume decreased by 8.6 percent, and relatively more fluid was lost from the thigh than the lower leg. The difference in volume changes in microgravity and simulated microgravity may be caused by the small transverse pressures still present in ground-based simulations and the extremely nonlinear compliance of tissue.

Thornton, William E.↗

Compressibility measurement of fluid-system ullage

Portable self-contained instrument measures volume of free gas or air trapped in closed fluid systems, such as lubricating-oil lines or hydraulic brakes. In response to measurement readings, operator may use device to accurately add or withdraw fluid to or from system.

Dzienis, D. A.↗

Efficient and robust stability analysis in the internal energy, volume, and moles (UVN) space

Hydrodynamic simulation of fluids in vessels is often based on the internal energy (U), volume (V), and the number of moles of all components ( re N = N 1 , N 2 , ..., N n ) as the working variables to determine the thermodynamic state by finding the global maximum of entropy. The procedure of finding the equilibrium state may be divided into two steps: stability analysis and phase-split computations. Stability analysis is performed first, and the phase-split computation proceeds if the system is unstable. Most of the past work on UVN space has been based on phase-split computations, while the stability analysis is barely investigated. Furthermore, previous studies for the stability analysis use only Newton's method to solve the non-linear algebraic equations. We present an efficient and robust approach for stability analysis where UVN is specified. The successive substitution iteration (SSI) is used to provide good initial guesses for Newton's method. The proposed approach results in a reduced number of unknowns and does not require a large number of iterations to achieve convergence in Newton's method. Overall, our proposed formulation is compatible with different equations of state and is applicable to both pure component and multi-components. The robustness and efficiency of the algorithm for stability analysis are demonstrated in various examples.

02 PETROLEUM↗

Modeling of Compressible Flow with Friction and Heat Transfer Using the Generalized Fluid System Simulation Program (GFSSP)

The present paper describes the verification and validation of a quasi one-dimensional pressure based finite volume algorithm, implemented in Generalized Fluid System Simulation Program (GFSSP), for predicting compressible flow with friction, heat transfer and area change. The numerical predictions were compared with two classical solutions of compressible flow, i.e. Fanno and Rayleigh flow. Fanno flow provides an analytical solution of compressible flow in a long slender pipe where incoming subsonic flow can be choked due to friction. On the other hand, Raleigh flow provides analytical solution of frictionless compressible flow with heat transfer where incoming subsonic flow can be choked at the outlet boundary with heat addition to the control volume. Nonuniform grid distribution improves the accuracy of numerical prediction. A benchmark numerical solution of compressible flow in a converging-diverging nozzle with friction and heat transfer has been developed to verify GFSSP's numerical predictions. The numerical predictions compare favorably in all cases.

Bandyopadhyay, Alak↗

Portable Intravenous Fluid Production Device For Ground Use Project

Several medical conditions require the administration of intravenous (IV) fluids,but limitations of mass, volume, shelf-life, transportation, and local resources can restrict the availability of these important fluids. Such limitations are expected in long-duration space exploration missions and in remote or austere places on Earth. This design uses regular drinking water that is pumped through two filters to produce, in minutes, sterile, ultrapure water that meets the stringent quality standards of the United States Pharmacopeia for Water for Injection (Total Bacteria, Conductivity, Endo - toxins, Total Organic Carbon). The device weighs 2.2 lb (1 kg) and is 10 in. long, 5 in. wide, and 3 in. high (≈25, 13, and 7.5 cm, respectively) in its storage configuration. This handheld device produces one liter of medical-grade water in 21 minutes. Total production capacity for this innovation is expected to be in the hundreds of liters. The device contains one battery powered electric mini-pump. Alternatively, a manually powered pump can be attached and used. Drinking water enters the device from a source water bag, flows through two filters, and final sterile production water exits into a sealed, medical-grade collection bag. The collection bag contains pre-placed crystalline salts to mix with product water to form isotonic intravenous medical solutions. Alternatively, a hypertonic salt solution can be injected into a filled bag. The filled collection bag is detached from the device and is ready for use or storage. This device currently contains one collection bag, but a manifold of several pre-attached bags or replacement of single collection bags under sterile needle technique is possible for the production of multiple liters. The entire system will be flushed, sealed, and radiation-sterilized. Operation of the device is easy and requires minimal training. Drinking water is placed into the collection bag. Inline stopcock flow valves at the source and collection bags are opened, and the mini-pump is turned on by a switch to begin fluid flow. When the collection bag is completely filled with the medical- grade water, the pump can be turned off. The pump is designed so it cannot pump air, and overfilling of the collection bag with fluid is avoided by placing an equal amount of water in the source bag. Backflow is avoided by inline check valves. The filled collection bag is disconnected from its tubing and is ready for use. The source bag can be refilled for production of multiple liters, or the source bag can be replaced with an input tube that can be placed in a larger potable water source if the device is attended. The device functions in all orientations independent of any gravity fields. In addition to creating IV fluids, the device produces medical-grade water, which can be used for mixing with medications for injection, reconstituting freeze-dried blood products for injection, or for wound hydration or irrigation. Potential worldwide use is expected with medical activities in environments that have limited resources, storage, or resupply such as in military field operations, humanitarian relief efforts, submarines, commercial cruise ships, etc.

Technology Portfolio System↗

The effect of fluid flow due to the crystal-melt density change on the growth of a parabolic isothermal dendrite

The Ivantsov (1947) analysis of an isolated isothermal dendrite (with zero surface tension) growing into a supercooled liquid is extended to include the effects of the fluid flow due to volume contraction or expansion upon solidification. For an axisymmetric paraboloidal dendrite, an analytic solution to the Navier-Stokes equations is obtained. The magnitude of the flow is proportional to the relative density change epsilon, and the flow becomes negligible far from the surface of the dendrite. The temperature field consistent with this flow can also be found explicitly. The well-known expression that relates the dimensionless supercooling to the Peclet number in the absence of fluid flow is modified for nonzero epsilon, but the effect is of order epsilon and hence is seen to be minor for most values of epsilon and dimensionless supercooling that occur in practice.

Mcfadden, G. B.↗

Electromagnetic probe technique for fluid flow measurements

The probes described herein, in various configurations, permit the measurement of the volume fraction of two or more fluids flowing through a pipe. Each probe measures the instantaneous relative dielectric constant of the fluid in immediate proximity. As long as separation of the relative dielectric constant of the fluid is possible, several or even many fluids can be measured in the same flow stream. By using multiple probes, the velocity of each fluid can generally be determined as well as the distribution of each constituent in the pipe. The values are determined by statistical computation. There are many potential applications for probes of this type in industry and government. Possible NASA applications include measurements of helium/hydrazine flow during rocket tests at White Sands, liquid/gas flow in hydrogen or oxygen lines in Orbiter engines, and liquid/gaseous Freon flow in zero gravity tests with the KS135 aircraft at JSC. Much interest has been shown recently by the oil industry. In this a good method is needed to measure the fractions of oil, water, and natural gas flowing in a pipeline and the velocity of each. This particular problem involves an extension of what has been developed to date and our plans to solve this problem will be discussed herein.

Arndt, G. D.↗

Electromagnetic Probe Technique for Fluid Flow Measurements

The probes described herein, in various configurations, permit the measurement of the volume fraction of two or more fluids flowing through a pipe. Each probe measures the instantaneous relative dielectric constant of the fluid in immediate proximity. As long as separation of the relative dielectric constants of each fluid is possible, several or even many fluids can be measured in the same flow steam. By using multiple probes, the velocity of each fluid can generally be determined as well as the distribution of each constituent in the pipe. The values are determined by statistical computation. There are many potential applications for probes of this type in industry and government. Possible NASA applications include measurements of helium/hydrazine flow during rocket tests at White Sands, liquid/gas flow in hydrogen or oxygen lines in Orbiter engines, and liquid/gaseous Freon flow in zero gravity tests with the KS135 aircraft at JSC. Much interest has been shown recently by the oil industry. In this industry, a good method is needed to measure the fractions of oil, water, and natural gas flowing in a pipeline and the velocity of each. This particular problem involves an extension of what has been developed to date and our plans and program to solve this problem will be discussed herein.

Arndt, G. D.↗

On the use of adjoints in the inversion of observed quasi-static deformation

An adjoint-based conjugate gradient algorithm provides an efficient means for imaging sources of deformation within the Earth, such as volume stresses associated with fluid flow in aquifers and reservoirs. For time intervals over which the overburden deforms elastically, one can calculate the gradient elements for a single model update using just two numerical simulations. The first is a forward run that is used to compute the residuals associated with the given iteration. The second simulation is to evaluate the application of the adjoint operator to the residuals. In this adjoint calculation, the residual displacements are applied as sources at the measurement locations, driving the deformation in the simulation. The volume stress on the source grid blocks, in response to the residual displacements, provide the gradient components. We apply this technique to satellite-based interferometric synthetic aperture radar (InSAR) line-of-sight displacements that were observed over an oil reservoir in California’s Central Valley. Furthermore, we find that the adjoint-based gradient estimates, requiring 18 CPU seconds, agree with conventional numerical calculations that take over 3700 CPU seconds to compute. Conjugate gradient algorithms utilizing the conventional approach and adjoint-based gradient computations give roughly the same reductions in misfit and similar final estimates of reservoir volume change.

58 GEOSCIENCES↗

Space Exploration Applications for Development of High Capacity Cryocoolers

Long term storage of cryogens is necessary to enable NASAs long duration crewed missions to both the lunar and Martian surfaces. Such missions require in-space transport systems such as Nuclear Thermal Propulsion (NTP), and descent/ascent vehicles for transportation to and from the lunar and Martian surfaces. NTP systems and Lunar/Martian landers utilize cryogenic fluids to minimize architectural volume and mass. To further enhance the capability of these cryogenic systems, the Agency is putting emphasis on reusability, which requires the NTP and ascent/descent elements be replenished on-orbit via tankers or propellant depots, or on the lunar or Martian surface using liquefied in-situ produced propellants. NTP is one of the leading propulsion option for human Mars missions and requires liquid hydrogen to be stored on-orbit for over four years. For such a long duration mission, near “Zero Boil-Off” (ZBO) must be achieved which requires an optimized suite of passive Cryogenic Fluid Management technologies and active cooling (cryocoolers). Tens of Watts of 20K cooling is required to achieve ZBO conditions for NTP, however two-stage cooling using both 20K and 90K systems can lead to a significant reduction in both active cooling mass and power. The use of in-situ resources for lunar and Martian missions will require 150 Watts of 90K cooling for oxygen liquefaction and 300 Watts of 20K cooling for hydrogen liquefaction (lunar only). Descent/Ascent vehicles, propellant depots, and tankers will also require the use of cryocoolers to achieve ZBO conditions. To support these programs, NASA is developing high capacity 20K and 90K reverse turbo-Brayton cycle cryocoolers which offer a scalable, high efficiency, low vibration solution.

cryocooler↗

Effect of the volume fraction gradient on the phase interaction force model for disperse two-phase flows

In this work, the effects of the particle volume fraction gradient on fluid-particle interactions are studied. The phase interaction force is decomposed into three terms. For the first term, namely the symmetrized force density, we present theoretical reasoning and numerical evidence to assume that it is independent of the particle volume fraction gradient. The second term is the particle volume fraction gradient times a newly introduced diffusion stress. The third term is the divergence of the particle-fluid-particle (PFP) stress. If this assumption of independence of the particle volume fraction gradient for the first term can be verified, to the first order of the ratio of the mean distance between particles to the macroscopic lengthscale, all three terms can be studied and modeled in flows with uniform particle distributions. Models thus obtained are applicable to statistically inhomogeneous flows, with the second and third terms accounting for statistical inhomogeneity. To verify this assumption, numerical simulations of flows passing fixed arrays of particles are performed. Both uniform and nonuniform particle volume fractions are studied and compared for disperse multiphase flows with the particle Reynolds numbers ranging from 1 to 100, and particle volume fraction ranging from 1% to 26% in statistically steady states. It is found that the symmetrized force (first) term can be well approximated by the drag force obtained from studies of uniform flows. The diffusion stress is positive along the flow direction and negative in the directions perpendicular to the flow. In the case of moving particles, this stress could potentially cause particle aggregation in the flow direction and dispersion in the directions perpendicular to the flow. Finally, the diffusion stress is only important when there is a volume fraction gradient, while the PFP stress can be important in inhomogeneous flows with either nonuniform particle concentrations or nonuniform average relative velocities between the phases.

42 ENGINEERING↗

Fractional watt Vuillemier cryogenic refrigerator program engineering notebook. Volume 1: Thermal analysis

The cryogenic refrigerator thermal design calculations establish design approach and basic sizing of the machine's elements. After the basic design is defined, effort concentrates on matching the thermodynamic design with that of the heat transfer devices (heat exchangers and regenerators). Typically, the heat transfer device configurations and volumes are adjusted to improve their heat transfer and pressure drop characteristics. These adjustments imply that changes be made to the active displaced volumes, compensating for the influence of the heat transfer devices on the thermodynamic processes of the working fluid. Then, once the active volumes are changed, the heat transfer devices require adjustment to account for the variations in flows, pressure levels, and heat loads. This iterative process is continued until the thermodynamic cycle parameters match the design of the heat transfer devices. By examing several matched designs, a near-optimum refrigerator is selected.

Miller, W. S.↗

Heat exchanger

A heat exchanger includes a shell housing a plurality of tubes and defining an exhaust fluid flow path within a first volume enclosed by the shell. The outer surfaces of the plurality of tubes are in fluid communication with the exhaust fluid flow path. The heat exchanger includes a cap attached to a first end of the shell and defining a second volume. A header is configured to separate the first volume from the second volume, flex with thermal expansion, and define tube inlet and outlet positions. The tube inlets and outlets are in fluid communication with a source fluid flow path, and each tube is substantially U-shaped and defines a flow path of the source fluid within the exhaust fluid flow path. The heat exchanger includes at least one longitudinal flow baffle within the shell configured to reduce an amount of exhaust fluid that may bypass the tubes.

Borghese, Joseph↗

Vascular Uptake of Six Rehydration Drinks at Rest and Exercise

A report presents data on the effectiveness of each of six rehydration fluids in restoring total body water and plasma volume in human subjects during rest and exercise. One of the six fluids was water sweetened with aspartame: the others were water containing various amounts of sodium chloride and/or sodium citrate, plus various amounts of aspartame and/or other carbohydrates. In one experiment, five men who had previously dehydrated themselves for 24 hours drank one of the rehydration fluids, then sat for 70 minutes. Pretest plasma volumes were measured and changes in plasma volumes were calculated. This procedure was repeated at weekly intervals until all six rehydration fluids had been tested. Another similar experiment involved four men who exercised on a cycle ergometer for 70 minutes in the supine position after drinking the fluids.

Greenleaf, J. E.↗