Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “VALIDATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

Expansion of the Verified, Archived, Library of Inputs and Data (VALID) [Slides]

This project dialogue provides an update on the Expansion of Verified, Archived, Library of Inputs and Data or VALID. VALID is a QA-Like (Quality Assurance) process to generate high quality models from reliable reference descriptions and make those models available to users. This presentation provides a brief project overview, a reminder of cases added in FY2021, cases currently in progress, and future plans for VALID.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

Applying Methodology for Evaluating and Validating TSLs to Materials of Interest to NCSP [Slides]

This presentation covers the topic of applying methodology for evaluation validation of TSLs to material of interest to the Nuclear Criticality Safety Program (NCSP). The talk covers recent efforts in validating thermal neutron scattering cross sections. The presentation also proposes a methodology for not only validating thermal scattering files that utilizes all available experimental data, but also for evaluating new libraries as demonstrated on Polystyrene and Lucite

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Validation and Verification of TEDS Facility HYBRID Modeling

The HYBRID modeling repository is an in-house developed library of models for selected integrated energy systems (IES) modelling. HYBRID models have been developed since 2015 to describe the physical operation of tightly coupled thermal systems including power generators, thermal transport systems, thermal storage, thermal-to-electric conversion systems, and other thermal applications. Here, validation and verification (V&V) capabilities are demonstrated using the Thermal Energy Distribution System (TEDS) at INL. Building upon prior work, the TEDS model has been updated and verified so that it better represents the installed system configuration and the operating control system. The model control system was changed to allow replication of actual experimental procedures. Experimental operations focusing primarily on thermocline tank performance were devised and performed. Several anomalies were found in the operation data of the experiment facility. V&V activities calibrating a selected input parameter are demonstrated on a single component as well as with a single parameter within the thermocline. Calibrating is then demonstrated on multiple components and a multi-parameter metric for the entire system. The validation methodology is successfully applied to validate the model with experimental data. It is also used to confirm a hypothesis behind one of the anomalies in experimental performance.

25 ENERGY STORAGE↗

HYBRID Modeling Validation and Verification Status Matrix

The HYBRID modeling repository is a premier resource for integrated energy systems modeling. HYBRID models have been developed since 2015 to describe the physical operation of tightly coupled thermal systems including power generators, thermal transport systems, thermal storage, thermal-to-electric conversion systems, and other thermal applications. Due to the increased size of the repository, a concise summary matrix of available models is desired. This matrix will consolidate not only the list of available models but also indicate original information sources, publications that have model examples, and level of validation and verification that exists for the models. Validation and verification (V&V) levels begin from simplified algebraic relationship and advance to dynamic data validation. Moving forward, as new models are contributed to HYBRID, their V&V level will be included, updating this matrix.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Improving Residential Building Simulations Through Large-Scale Empirical Validation

Residential building energy simulations are increasingly used for energy-efficient building design, codes and standards analysis, home certifications and ratings, utility programs, and technology assessments. Various software tools exist to perform residential building simulations, and these tools often use different models, inputs, and assumptions. This leads to inconsistencies that can undermine confidence in the predicted results. Validation of these tools can increase confidence by ensuring their accuracy and consistency. One way to validate simulation tools is through empirical testing, which compares predicted energy usage to measured utility billing data. This paper describes the process of data collection, data standardization, and empirical validation, and illustrates its use with our residential EnergyPlus (R)-based software. The data and process can be extended to other simulation tools and contribute to improving residential building simulations more broadly.

empirical validation↗

ACCRUE—An Integral Index for Measuring Experimental Relevance in Support of Neutronic Model Validation

A key challenge for the introduction of any design changes, e.g., advanced fuel concepts, first-of-a-kind nuclear reactor designs, etc., is the cost of the associated experiments, which are required by law to validate the use of computer models for the various stages, starting from conceptual design, to deployment, licensing, operation, and safety. To achieve that, a criterion is needed to decide on whether a given experiment, past or planned, is relevant to the application of interest. This allows the analyst to select the best experiments for the given application leading to the highest measures of confidence for the computer model predictions. The state-of-the-art methods rely on the concept of similarity or representativity, which is a linear Gaussian-based inner-product metric measuring the angle—as weighted by a prior model parameters covariance matrix—between two gradients, one representing the application and the other a single validation experiment. This manuscript emphasizes the concept of experimental relevance which extends the basic similarity index to account for the value accrued from past experiments and the associated experimental uncertainties, both currently missing from the extant similarity methods. Accounting for multiple experiments is key to the overall experimental cost reduction by prescreening for redundant information from multiple equally-relevant experiments as measured by the basic similarity index. Accounting for experimental uncertainties is also important as it allows one to select between two different experimental setups, thus providing for a quantitative basis for sensor selection and optimization. The proposed metric is denoted by ACCRUE, short for Accumulative Correlation Coefficient for Relevance of Uncertainties in Experimental validation. Using a number of criticality experiments for highly enriched fast metal systems and low enriched thermal compound systems with accident tolerant fuel concept, the manuscript will compare the performance of the ACCRUE and basic similarity indices for prioritizing the relevance of a group of experiments to the given application.

97 MATHEMATICS AND COMPUTING↗

Anion exchange membrane test protocol validation

This study presents the validation of protocols for measuring ion exchange capacity (IEC) and alkaline stability of anion exchange membranes (AEMs) for low-temperature water electrolysis. While protocols are often tested within individual laboratories, their results across multiple laboratories with varying equipment, environmental conditions, and personnel qualification remain unverified. The validation involved Los Alamos National Laboratory (LANL), National Renewable Energy Laboratory (NREL), and University of Oregon (UO) using the same commercially available AEM to assess reproducibility and reliability of the protocols under diverse conditions. For the IEC protocol, results across laboratories were consistent within ±10% of the NMR-determined reference value. The alkaline stability protocol could pose greater challenges due to factors such as variations in sample collection timing, preservation methods, and analytical techniques, but consistent test results for percentage IEC loss were demonstrated across institutions. These results highlight the reliability and applicability of the protocols, emphasizing the importance of validation to ensure consistency in diverse research environments.

08 HYDROGEN↗

Development of Training Materials for Pathologists to Provide Machine Learning Validation Data of Tumor-Infiltrating Lymphocytes in Breast Cancer

The High Throughput Truthing project aims to develop a dataset for validating artificial intelligence and machine learning models (AI/ML) fit for regulatory purposes. The context of this AI/ML validation dataset is the reporting of stromal tumor-infiltrating lymphocytes (sTILs) density evaluations in hematoxylin and eosin-stained invasive breast cancer biopsy specimens. After completing the pilot study, we found notable variability in the sTILs estimates as well as inconsistencies and gaps in the provided training to pathologists. Using the pilot study data and an expert panel, we created custom training materials to improve pathologist annotation quality for the pivotal study. We categorized regions of interest (ROIs) based on their mean sTILs density and selected ROIs with the highest and lowest sTILs variability. In a series of eight one-hour sessions, the expert panel reviewed each ROI and provided verbal density estimates and comments on features that confounded the sTILs evaluation. We aggregated and shaped the comments to identify pitfalls and instructions to improve our training materials. From these selected ROIs, we created a training set and proficiency test set to improve pathologist training with the goal to improve data collection for the pivotal study. We are not exploring AI/ML performance in this paper. Instead, we are creating materials that will train crowd-sourced pathologists to be the reference standard in a pivotal study to create an AI/ML model validation dataset. The issues discussed here are also important for clinicians to understand about the evaluation of sTILs in clinical practice and can provide insight to developers of AI/ML models.

60 APPLIED LIFE SCIENCES↗

Ten Years of VIIRS Land Surface Temperature Product Validation

The Visible Infrared Imaging Radiometer Suite (VIIRS) Land Surface Temperature (LST) has been operationally produced for a decade since the Suomi National Polar-orbiting Partnership (SNPP) launched in October 2011. A comprehensive evaluation of its accuracy and precision will be helpful for product users in climate studies and atmospheric models. In this study, the VIIRS LST is validated with ground observations from multiple high-quality radiation networks, including six stations from the Surface Radiation budget (SURFRAD) network, two stations from the Baseline Surface Radiation Network (BSRN), and 13 stations from the Atmospheric Radiation Measurement (ARM) network, to evaluate its performance over various land-cover types. The VNP21A1 LST was validated against the same ground observations as a reference. The results yield a close agreement between the SNPP VIIRS LST and ground LSTs with a bias of -0.4 K and a RMSE of 1.96 K over six SURFRAD sites; a bias of -0.2 K and a RMSE of 1.93 K over two BSRN sites; and a bias of -0.1 K and a RMSE of 1.7 K over the 13 ARM sites. The time series of the LST errors over individual sites indicate seasonal cycles. The data anomaly over the BSRN site in Cabauw and the SURFRAD site in Desert Rock is revealed and discussed in this study. In addition, a method using Landsat-8 data is applied to quantify the heterogeneity level of each ground station and the results provide promising insights. The validation results demonstrate the maturity of the JPSS VIIRS LST products and their readiness for various application studies.

54 ENVIRONMENTAL SCIENCES↗

Assessing Technology Maturity for ST-9 Technology Validation Experiments

This viewgraph presentation reviews the process of assessing the maturity of a technology for use in NASA missions. The NASA New Millennium Program (NMP) identifies and flight validates breakthrough technologi es that will significantly benefit future operational Space and Earth Science missions NMP conducts two types of flight validation projec ts for the Space Science Enterprise: (1) Integrated System Validatio n Projects, and (2) Stand-Alone Subsystem Validation Projects.

Space Technology (ST) 9↗

Thermal Design Validation of the Mars Scout Phoenix Payload

This slide presentation reviews the validation of the thermal design for the Mars Scout Phoenix Payload. It includes a description of the Phoenix Mission, the science objectives, the timeline, and the flight system and payloads that were on the lander. The initial responsibility for the development and validation the thermal design was with the developers. This process lacked overall system engineering, there was a difference of thermal expertise, and the number of institutions involved complicated the interactions. The revised approach for payload thermal design validation is described.

thermal design validation↗

Retrieval, Inter-Comparison, and Validation of Above-Cloud Aerosol Optical Depth from A-train Sensors

Absorbing aerosols produced from biomass burning and dust outbreaks are often found to overlay lower level cloud decks and pose greater potentials of exerting positive radiative effects (warming) whose magnitude directly depends on the aerosol loading above cloud, optical properties of clouds and aerosols, and cloud fraction. Recent development of a 'color ratio' (CR) algorithm applied to observations made by the Aura/OMI and Aqua/MODIS constitutes a major breakthrough and has provided unprecedented maps of above-cloud aerosol optical depth (ACAOD). The CR technique employs reflectance measurements at TOA in two channels (354 and 388 nm for OMI; 470 and 860 nm for MODIS) to retrieve ACAOD in near-UV and visible regions and aerosol-corrected cloud optical depth, simultaneously. An inter-satellite comparison of ACAOD retrieved from NASA's A-train sensors reveals a good level of agreement between the passive sensors over the homogeneous cloud fields. Direct measurements of ACA such as carried out by the NASA Ames Airborne Tracking Sunphotometer (AATS) and Spectrometer for Sky-Scanning, Sun-Tracking Atmospheric Research (4STAR) can be of immense help in validating ACA retrievals. We validate the ACA optical depth retrieved using the CR method applied to the MODIS cloudy-sky reflectance against the airborne AATS and 4STAR measurements. A thorough search of the historic AATS-4STAR database collected during different field campaigns revealed five events where biomass burning, dust, and wildfire-emitted aerosols were found to overlay lower level cloud decks observed during SAFARI-2000, ACE-ASIA 2001, and SEAC4RS- 2013, respectively. The co-located satellite-airborne measurements revealed a good agreement (RMSE less than 0.1 for AOD at 500 nm) with most matchups falling within the estimated uncertainties in the MODIS retrievals. An extensive validation of satellite-based ACA retrievals requires equivalent field measurements particularly over the regions where ACA are often observed from satellites, i.e., south-eastern Atlantic Ocean, tropical Atlantic Ocean, northern Arabian Sea, South-East and North-East Asia.

validation↗

Integrated Medical Model Verification, Validation, and Credibility

The Integrated Medical Model (IMM) was designed to forecast relative changes for a specified set of crew health and mission success risk metrics by using a probabilistic (stochastic process) model based on historical data, cohort data, and subject matter expert opinion. A probabilistic approach is taken since exact (deterministic) results would not appropriately reflect the uncertainty in the IMM inputs. Once the IMM was conceptualized, a plan was needed to rigorously assess input information, framework and code, and output results of the IMM, and ensure that end user requests and requirements were considered during all stages of model development and implementation. METHODS: In 2008, the IMM team developed a comprehensive verification and validation (VV) plan, which specified internal and external review criteria encompassing 1) verification of data and IMM structure to ensure proper implementation of the IMM, 2) several validation techniques to confirm that the simulation capability of the IMM appropriately represents occurrences and consequences of medical conditions during space missions, and 3) credibility processes to develop user confidence in the information derived from the IMM. When the NASA-STD-7009 (7009) was published, the IMM team updated their verification, validation, and credibility (VVC) project plan to meet 7009 requirements and include 7009 tools in reporting VVC status of the IMM. RESULTS: IMM VVC updates are compiled recurrently and include 7009 Compliance and Credibility matrices, IMM VV Plan status, and a synopsis of any changes or updates to the IMM during the reporting period. Reporting tools have evolved over the lifetime of the IMM project to better communicate VVC status. This has included refining original 7009 methodology with augmentation from the NASA-STD-7009 Guidance Document. End user requests and requirements are being satisfied as evidenced by ISS Program acceptance of IMM risk forecasts, transition to an operational model and simulation tool, and completion of service requests from a broad end user consortium including Operations, Science and Technology Planning, and Exploration Planning. CONCLUSIONS: The VVC approach established by the IMM project of combining the IMM VV Plan with 7009 requirements is comprehensive and includes the involvement of end users at every stage in IMM evolution. Methods and techniques used to quantify the VVC status of the IMM have not only received approval from the local NASA community but have also garnered recognition by other federal agencies seeking to develop similar guidelines in the medical modeling community.

Validation↗

Qualitative Validation of the IMM Model for ISS and STS Programs

To validate and further improve the Integrated Medical Model (IMM), medical event data were obtained from 32 ISS and 122 STS person-missions. Using the crew characteristics from these observed missions, IMM v4.0 was used to forecast medical events and medical resource utilization. The IMM medical condition incidence values were compared to the actual observed medical event incidence values, and the IMM forecasted medical resource utilization was compared to actual observed medical resource utilization. Qualitative comparisons of these parameters were conducted for both the ISS and STS programs. The results of these analyses will provide validation of IMM v4.0 and reveal areas of the model requiring adjustments to improve the overall accuracy of IMM outputs. This validation effort should result in enhanced credibility of the IMM and improved confidence in the use of IMM as a decision support tool for human space flight.

risk assessment↗

Recalibration and Validation of the SMAP L-Band Radiometer

SMAP mission was launched on 31st January 2015 in a 6 AM 6 PM sun-synchronous orbit at 685 km altitude to measure soil moisture and freethaw globally. The passive instrument of SMAP is a fully polarimetric L-band radiometer (1.4GHz) operating with a bandwidth of 24MHz. The radiometer L1B data product version 3 has been released for public science activities. Post-launch calibration and validation activities are described in [4,5]. Validation results show that SMAP antenna temperature (TA) is 2.6 K warmer over galactic Cold Sky (CS), and land TB is 2.6 K colder comparing to SMOS land TB (compared at the top of the atmosphere) after the update of the reflectors thermal model. Due to the biases, the SMAP radiometer is under re-calibration for next data release in 2018.We present the updated calibration approaches for the SMAP radiometer product. We will discuss the various radiometer calibration parameters and part of the validation process and result.

SMAP↗

Quantitative Validation of the Integrated Medical Model (IMM) for ISS Missions

Lifetime Surveillance of Astronaut Health (LSAH) provided observed medical event data on 33 ISS and 111 STS person-missions for use in further improving and validating the Integrated Medical Model (IMM). Using only the crew characteristics from these observed missions, the newest development version, IMM v4.0, will simulate these missions to predict medical events and outcomes. Comparing IMM predictions to the actual observed medical event counts will provide external validation and identify areas of possible improvement. In an effort to improve the power of detecting differences in this validation study, the total over each program ISS and STS will serve as the main quantitative comparison objective, specifically the following parameters: total medical events (TME), probability of loss of crew life (LOCL), and probability of evacuation (EVAC). Scatter plots of observed versus median predicted TMEs (with error bars reflecting the simulation intervals) will graphically display comparisons while linear regression will serve as the statistical test of agreement. Two scatter plots will be analyzed 1) where each point reflects a mission and 2) where each point reflects a condition-specific total number of occurrences. The coefficient of determination (R2) resulting from a linear regression with no intercept bias (intercept fixed at zero) will serve as an overall metric of agreement between IMM and the real world system (RWS). In an effort to identify as many possible discrepancies as possible for further inspection, the -level for all statistical tests comparing IMM predictions to observed data will be set to 0.1. This less stringent criterion, along with the multiple testing being conducted, should detect all perceived differences including many false positive signals resulting from random variation. The results of these analyses will reveal areas of the model requiring adjustment to improve overall IMM output, which will thereby provide better decision support for mission critical applications.

validation↗

Validation of the Nasa Integrated Medical Model: a Space Flight Medical Risk Prediction Tool

The Human Research Program funded the development of the Integrated Medical Model (IMM) to quantify the medical component of overall mission risk. The IMM uses Monte Carlo simulation methodology, incorporating space flight and ground medical data, to estimate the probability of mission medical outcomes and resource utilization. To determine the credibility of IMM output, the IMM project team completed two validation studies that compared IMM predicted output to observed medical events from a selection of Shuttle Transportation System (STS) and International Space Station (ISS) missions. The validation study results showed that the IMM underpredicted the occurrence of ~10% of the modeled medical conditions for the STS missions and overpredicted ~20% of the modeled medical conditions for the ISS missions. These findings imply that the strength of IMM predictions to inform decisions depends on simulated mission specifications including length. This discrepancy could result from medical recording differences between ISS and STS that possibly influence observed incidence rates, IMM combining all "mission type" data as constant occurrence rate or fixed proportion across both mission types, misspecification of symptoms to conditions, and gaps in the literature informing the model. Some of these issues will be alleviated by updating the IMM source data through incorporation of the observed validation data.

medical equipment↗

Validation of the NASA Integrated Medical Model: a Space Flight Medical Risk Prediction Tool

The Human Research Program funded the development of the Integrated Medical Model (IMM) to quantify the medical component of overall mission risk. The IMM uses Monte Carlo simulation methodology, incorporating space flight and ground medical data, to estimate the probability of mission medical outcomes and resource utilization. To determine the credibility of IMM output, the IMM project team completed two validation studies that compared IMM predicted output to observed medical events from a selection of Shuttle Transportation System (STS) and International Space Station (ISS) missions. The validation study results showed that the IMM underpredicted the occurrence of ~10% of the modeled medical conditions for the STS missions and overpredicted ~20% of the modeled medical conditions for the ISS missions. These findings imply that the strength of IMM predictions to inform decisions depends on simulated mission specifications including length. This discrepancy could result from medical recording differences between ISS and STS that possibly influence observed incidence rates, IMM combining all "mission type" data as constant occurrence rate or fixed proportion across both mission types, misspecification of symptoms to conditions, and gaps in the literature informing the model. Some of these issues will be alleviated by updating the IMM source data through incorporation of the observed validation data.

risk assessment↗