Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ULTRASOUND”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

SU-G-IeP4-15: Ultrasound Imaging of Absorbable Inferior Vena Cava Filters for Proper Placement

Purpose: Inferior vena cava filters (IVCFs) are used in patients with a high risk of pulmonary embolism in situations when the use of blood thinning drugs would be inappropriate. These filters are implanted under x-ray guidance; however, this provides a dose of ionizing radiation to both patient and physician. B-mode ultrasound (US) imaging allows for localization of certain implanted devices without radiation dose concerns. The goal of this study was to investigate the feasibility of imaging the placement of absorbable IVCFs using US imaging to alleviate the dosage concern inherent to fluoroscopy. Methods: A phantom was constructed to mimic a human IVC using tissue-mimicking material with 0.5 dB/cm/MHz acoustic attenuation, while agar inclusions were used to model acoustic mismatch at the venous interface. Absorbable IVCF’s were imaged at 15 cm depth using B-mode US at 2, 3, 5, and 7 MHz transmit frequencies. Then, to determine temporal stability, the IVCF was left in the phantom for 10 weeks; during this time, the IVCF was imaged using the same techniques as above, while the integrity of the filter was analyzed by inspecting for fiber discontinuities. Results: Visualization of the inferior vena cava filter was possible at 5, 7.5, and 15 cm depth at US central frequencies of 2, 3, 5, and 7 MHz. Imaging the IVCF at 5 MHz yielded the clearest images while maintaining acceptable spatial resolution for identifying the IVCF’s, while lower frequencies provided noticeably worse image quality. No obvious degradation was observed over the course of the 10 weeks in a static phantom environment. Conclusion: Biodegradable IVCF localization was possible up to 15 cm in depth using conventional B-mode US in a tissue-mimicking phantom. This leads to the potential for using B-mode US to guide the placement of the IVCF upon deployment by the interventional radiologist. Mitch Eggers is an owner of Adient Medical Technologies. There are no other conflicts of interest to disclose.

60 APPLIED LIFE SCIENCES↗

MO-B-BRC-02: Ultrasound Based Prostate HDR

Brachytherapy has proven to be an effective treatment option for prostate cancer. Initially, prostate brachytherapy was delivered through permanently implanted low dose rate (LDR) radioactive sources; however, high dose rate (HDR) temporary brachytherapy for prostate cancer is gaining popularity. Needle insertion during prostate brachytherapy is most commonly performed under ultrasound (U/S) guidance; however, treatment planning may be performed utilizing several imaging modalities either in an intra- or post-operative setting. During intra-operative prostate HDR, the needles are imaged during implantation, and planning may be performed in real time. At present, the most common imaging modality utilized for intra-operative prostate HDR is U/S. Alternatively, in the post-operative setting, following needle implantation, patients may be simulated with computed tomography (CT) or magnetic resonance imaging (MRI). Each imaging modality and workflow provides its share of benefits and limitations. Prostate HDR has been adopted in a number of cancer centers across the nation. In this educational session, we will explore the role of U/S, CT, and MRI in HDR prostate brachytherapy. Example workflows and operational details will be shared, and we will discuss how to establish a prostate HDR program in a clinical setting. Learning Objectives: Review prostate HDR techniques based on the imaging modality Discuss the challenges and pitfalls introduced by the three imagebased options for prostate HDR brachytherapy Review the QA process and learn about the development of clinical workflows for these imaging options at different institutions.

60 APPLIED LIFE SCIENCES↗

MO-DE-202-01: Image-Guided Focused Ultrasound Surgery and Therapy

At least three major trends in surgical intervention have emerged over the last decade: a move toward more minimally invasive (or non-invasive) approach to the surgical target; the development of high-precision treatment delivery techniques; and the increasing role of multi-modality intraoperative imaging in support of such procedures. This symposium includes invited presentations on recent advances in each of these areas and the emerging role for medical physics research in the development and translation of high-precision interventional techniques. The four speakers are: Keyvan Farahani, “Image-guided focused ultrasound surgery and therapy” Jeffrey H. Siewerdsen, “Advances in image registration and reconstruction for image-guided neurosurgery” Tina Kapur, “Image-guided surgery and interventions in the advanced multimodality image-guided operating (AMIGO) suite” Raj Shekhar, “Multimodality image-guided interventions: Multimodality for the rest of us” Learning Objectives: Understand the principles and applications of HIFU in surgical ablation. Learn about recent advances in 3D–2D and 3D deformable image registration in support of surgical safety and precision. Learn about recent advances in model-based 3D image reconstruction in application to intraoperative 3D imaging. Understand the multi-modality imaging technologies and clinical applications investigated in the AMIGO suite. Understand the emerging need and techniques to implement multi-modality image guidance in surgical applications such as neurosurgery, orthopaedic surgery, vascular surgery, and interventional radiology. Research supported by the NIH and Siemens Healthcare.; J. Siewerdsen; Grant Support - National Institutes of Health; Grant Support - Siemens Healthcare; Grant Support - Carestream Health; Advisory Board - Carestream Health; Licensing Agreement - Carestream Health; Licensing Agreement - Elekta Oncology.; T. Kapur, P41EB015898; R. Shekhar, Funding: R42CA137886 and R41CA192504 Disclosure and CoI: IGI Technologies, small-business partner on the grants.

60 APPLIED LIFE SCIENCES↗

WE-AB-BRA-03: Non-Invasive Controlled Release from Implantable Hydrogel Scaffolds Using Ultrasound

Purpose: To control release of a model payload in acoustically responsive scaffolds (ARSs) using focused ultrasound (FUS). Methods: Fluorescently-labeled dextran (10 kDa) was encapsulated in sonosensitive perfluorocarbon (C{sub 6}F{sub 14} or C{sub 5}F{sub 12}) double emulsions (mean diameter: 2.9±0.1 µm). For in vitro release studies, 0.5 mL ARSs (10 mg/mL fibrin, 1% (v/v) emulsion) were polymerized in 24 well plates and covered with 0.5 mL medium. Starting one day after polymerization, ARSs were exposed to FUS (2.5 MHz, Pr = 8 MPa, 13 cycles, 100 Hz PRF) for 2 min daily. The amount of dextran released into the media was quantified. For in vivo studies, 0.25 mL ARSs were prepared as described previously and injected subcutaneously in the lower back of BALB/c mice. After polymerization, a subset of the implanted ARSs were exposed to FUS (as previously described). Animals were imaged longitudinally using a fluorescence imaging system to quantify the amount of dextran released from the ARSs. Results: In vitro: Over 6 days, +FUS displayed an 8.2-fold increase in dextran release compared to −FUS (−FUS: 2.7±0.6%; +FUS: 22.2±3.0%) for C{sub 6}F{sub 14} ARSs, and a 6.7-fold increase (−FUS: 5.0±0.8%; +FUS: 38.5±1.6%) for C{sub 5}F{sub 12}:C{sub 6}F{sub 14} ARSs. In vivo: +FUS displayed statistically greater dextran release compared to −FUS one day after implantation for C{sub 5}F{sub 12}:C{sub 6}F{sub 14} ARSs (−FUS: 55.1±1.5%; +FUS: 74.1±2.2%) and three days after implantation for C{sub 6}F{sub 14} ARSs (−FUS: 1.4±6.5%; +FUS: 30.4±5.4%). Conclusion: FUS enables non-invasive control of payload release from an ARS, which could benefit growth factor delivery for tissue regeneration. ARS are versatile due to their tunability (i.e. stiffness, emulsion composition, FUS pressure, FUS frequency, etc.) and can be modified to for optimal payload release. Future work will optimize ARS formulations for in vivo use to minimize payload release in the absence of FUS. This work was supported by NIH Grant R21 AR065010 (M.L. Fabiilli) and the Basic Radiologic Sciences Innovative Research Award (M.L. Fabiilli). A. Moncion is supported by the National Science Foundation Graduate Student Research Fellowship (Grant DGE 1256260).

60 APPLIED LIFE SCIENCES↗

Application of entropy and signal energy for ultrasound-based classification of three-dimensional printed polyetherketoneketone components

This paper describes a preliminary method for the classification of annealed and unannealed polyetherketoneketone (PEKK) components manufactured using a material extrusion three-dimensional (3D) printing process. PEKK is representative of a class of high-performance thermoplastics that are increasingly employed as feedstocks for use in 3D printing. PEKK components may be used continuously at elevated temperatures, are chemically resistant, and able to withstand large mechanical loads. These properties render PEKK suitable as a metal component replacement in aerospace applications, high-temperature industrial applications, and surgical implants. The structure of PEKK is semi-crystalline with the specific crystallinity correlating to the final properties during application, making determination of this property crucial. This study compares three different signal processing techniques intended to distinguish annealed (high crystallinity) from unannealed (low crystallinity) components using backscattered ultrasound. The first is energy-based and is unable to detect annealing. The second two are based on different entropies of the backscattered signal: a limiting form of Renyi's entropy and a limiting form of joint entropy. The joint entropy values for the annealed and unannealed specimens fall into two non-overlapping intervals and have a statistical separation of two standard deviations.

36 MATERIALS SCIENCE↗

Enhanced resonant ultrasound spectroscopy for measurement of the elastic properties of multi-material systems

Understanding the elastic properties of materials is critical for their safe incorporation and predictable performance. Current methods of bulk elastic characterization often have notable limitations for in situ structural applications, with usage restricted to simple geometries and material distributions. To address these existing issues, this study sought to expand the capabilities of resonant ultrasound spectroscopy (RUS), an established nondestructive evaluation method, to include the characterization of isotropic multi-material samples. In this work, finite-element-based RUS analysis consisted of numerical simulations and experimental testing of composite samples comprised of material pairs with varying elasticity and density contrasts. Utilizing genetic algorithm inversion and mode matching, our results demonstrate that elastic properties of multi-material samples can be reliably identified within several percent of known or nominal values using a minimum number of identified resonance modes, given sample mass is held consistent. The accurate recovery of material properties for composite samples of varying material similarity and geometry expands the pool of viable samples for RUS and advances the method towards in situ inspection and evaluation.

36 MATERIALS SCIENCE↗

Enabling resonant ultrasound spectroscopy in high magnetic fields

Resonant ultrasound spectroscopy (RUS) is a powerful method to determine elastic constants with high accuracy and precision from a single measurement of the mechanical resonances of a sample. Conventionally, the quantitative extraction of elastic moduli with RUS assumes free boundary conditions which can often lead to the adoption of unstable sample positioning between ultrasonic transducers that is incompatible with extreme environments like high magnetic fields. We show that, under specific conditions, introducing a small amount of adhesive between a RUS sample and ultrasonic transducers introduces a perturbation to the free resonance condition which can be accounted for by a simple model. This means elastic constants can be determined to within the uncertainty of conventional RUS, but with significant improvements including sample stability and control of sample orientation. We demonstrate the efficacy of this approach with measurements on a range of materials including room temperature measurements on polycrystalline metals, temperature-dependent measurements of the structural phase transition in strontium titanate single crystals, and magnetic field-dependent measurements of magnetic phase transitions in gadolinium polycrystals up to 14 T.

47 OTHER INSTRUMENTATION↗

Resonant ultrasound spectroscopy probe for in-situ neutron scattering measurements

Resonant ultrasound spectroscopy (RUS) is an efficient, nondestructive technique to study the elastic properties of solids. A low-temperature (2-300 K) probe has been assembled and tested at the NOMAD beamline at the Spallation Neutron Source at Oak Ridge National Laboratory to assess the probe's neutronic properties, data acquisition system, and compatibility with existing sample environment. A case study on a bulk metallic glass, La 65 Cu 20 Al 10 Co 5, served to benchmark both hardware and software developments. The elastic constants of the metallic glass were determined as a function of temperature between 4 and 300 K and were used to guide neutron diffraction measurements at NOMAD. Tracking of a specific RUS peak center frequency and width enabled live monitoring of the sample temperature evolution that lagged thermometry by upwards of 40 K near room temperature. Assembly of a high-temperature (300-875 K) probe is underway and both probes are scheduled to be available to users by late-2021. Our aim is to provide users with live monitoring of an intrinsic variable at the neutron scattering beamlines, in addition to existing controls, to monitor the state of their samples and its elastic moduli and make informed decisions in real time.

Torres, James↗

On the nature of the orientational effect of ultrasound on nematic liquid crystal

Experimental substantiation of the validity of the model of orientational distortion in a homeotropic layer of nematic liquid crystal under an ultrasonic beam with a sharp boundary is presented for the first time. The model is constructed within the concepts of nonequilibrium thermodynamics and statistical hydrodynamics, taking into account the processes of structural relaxation of the mesophase. It establishes the relationship between the characteristics specifying the homeotropic structure deformation (layer thickness, ultrasound frequency, parameters of the molecular micromodel of liquid crystal, and its material constants) and the layer transparency for a linearly polarized light beam. The calculation results are compared with the experimental data in the frequency range of 0.1–3 MHz.

42 ENGINEERING↗

FLC Nomination: Super-Resolution Ultrasound Imaging For Detecting Breast Microcalcifications

Women with high breast densities are more likely to develop breast cancer in their lifetime. Yet, these are the very women for whom X-ray mammography, the conventional method for breast cancer detection, is highly unreliable. Los Alamos National Laboratory’s (LANL or the Laboratory) super-resolution ultrasound imaging technology can provide a powerful tool for reliable, safe, and frequent exams for women with a higher risk of breast cancer without ionizing radiation, and bring us closer to eradicating breast cancer.

59 BASIC BIOLOGICAL SCIENCES↗

Laser Ultrasound Spectroscopy Scanning for 3D Printed Parts

One of the challenges of additive manufacturing is quality control due to the possibility of unseen flaws in the final product. The current methods of inspection are lacking in detail, too slow for practical use, or unable to validate internal structure. This report examines the use of laser ultrasound spectroscopy in layer by layer scans of 3D printed parts as they are created. The result is fast and detailed quality control. An additional advantage of this method is the ability to cancel a print as soon as a defect is detected, therefore saving materials and time. This technique, though simple in concept, has been a challenge to implement. I discuss tweaking the 3D printer configuration, and finding the optimal settings for laser scanning small parts made of ABS plastic, as well as the limits of how small of a detail the laser can detect. These settings include the frequency of the ultrasonic transducer, the speed of the laser, and the distance from the laser to the part.

47 OTHER INSTRUMENTATION↗

Ultrasound Interim cyber-physical research evaluation

Recent events have presented Medical Practitioners with concerns about safety and privacy implications associated with GE’s VScan MIot Ultrasound Device. Concerns relate to the devices potential risk to broadcast location data that can pose serious risks to device users and patients. This report was commission in collaboration with Augusta University to determine if device concerns pose real threat to operators and patients. In effort to ensure all potential threat vectors are targeted, the initial step was to analyze the supply chain. Here the devices are CT scanned to look for any hardware anomalies that could present threat vectors to users of these devices. (See SRNL-STI-2024-00225 for detailed analysis). No anomalies were found associated with the hardware utilized within the GE VScan Air.

42 ENGINEERING↗

Additive Manufacturing with Ultrasound

Additive manufacturing methods are briefly reviewed. Proposals are outlined for the use of ultrasound in fused deposition modeling (FDM) and selective laser melting (SLM). Approaches to ultrasonic additive manufacturing (UAM) are discussed.

42 ENGINEERING↗

Grinding Forces in the Presence of Ultrasound

Formulas are derived for calculation of the grinding force in the presence of ultrasound whose amplitude changes the microcutting kinematics of the abrasive grains. The formulas are verified experimentally.

42 ENGINEERING↗

Improvement in Ultrasound Liquid Machining by Activating Cavitational Clusters

In the erosion-free zone that appears during high-amplitude ultrasound treatment, the useful work is mainly performed by cavitational clusters. In the absence of collapse, the clusters grow and produce small-scale turbulence. As shown in the present work, cavitational clusters may be activated by the additional acoustic pressure arising when a low-amplitude source is coaxial with the high-amplitude source.

42 ENGINEERING↗

Holey-Cavity-Based Compressive Sensing for Ultrasound Imaging

The use of solid cavities around electromagnetic sources has been recently reported as a mechanism to provide enhanced images at microwave frequencies. These cavities are used as measurement randomizers; and they compress the wave fields at the physical layer. As a result of this compression, the amount of information collected by the sensing array through the different excited modes inside the resonant cavity is increased when compared to that obtained by no-cavity approaches. In this work, a two-dimensional cavity, having multiple openings, is used to perform such a compression for ultrasound imaging. Moreover, compressive sensing techniques are used for sparse signal retrieval with a limited number of operating transceivers. As a proof-of-concept of this theoretical investigation, two point-like targets located in a uniform background medium are imaged in the presence and the absence of the cavity. In addition, an analysis of the sensing capacity and the shape of the point spread function is also carried out for the aforementioned cases. The cavity is designed to have the maximum sensing capacity given different materials and opening sizes. It is demonstrated that the use of a cavity, whether it is made of plastic or metal, can significantly enhance the sensing capacity and the point spread function of a focused beam. The imaging performance is also improved in terms cross-range resolution when compared to the no-cavity case

42 ENGINEERING↗