Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Tomography”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

Electron tomography of dislocation structures

Recent developments in the application of electron tomography for characterizing microstructures in crystalline solids are described. The underlying principles for electron tomography are presented in the context of typical challenges in adapting the technique to crystalline systems and in using diffraction contrast imaging conditions. Methods for overcoming the limitations associated with the angular range, the number of acquired images, and uniformity of image contrast are introduced. In addition, a method for incorporating the real space coordinate system into the tomogram is presented. As the approach emphasizes development of experimental solutions to the challenges, the solutions developed and implemented are presented in the form of examples.

36 MATERIALS SCIENCE↗

X-ray micro-tomography investigation of the foaming process in the system of waste glass–silica mud–MnO{sub 2}

In case of foamed lightweight aggregates (LWAs), porosity is introduced by the addition of a foaming agent to the glassy matrix, which degasses at an elevated temperature, so that the resulting gases remain trapped inside the glassy structure. The efficiency of action of MnO{sub 2} as a foaming agent in waste glass and waste glass/silica mud systems was studied. Samples were fired at different temperatures and with different dwelling times at a certain temperature, and the development of porosity was investigated by means of X-ray micro-tomography. It was found that, with the prolongation in dwelling times, the number of pores decreased, while, on the other hand, the volume of these pores increased, and that the addition of silica mud increases the foaming temperature and slows down the foaming process. - Highlights: • Preparation of lightweight aggregate from waste glass, silica sludge, and MnO{sub 2} • DTA/TG investigation of MnO{sub 2} • Characterization of pore-forming process by means of X-ray micro-tomography (μcT)

36 MATERIALS SCIENCE↗

Development of a lab-scale, high-resolution, tube-generated X-ray computed-tomography system for three-dimensional (3D) materials characterization

The design and construction of a modular high resolution X-ray computed tomography (XCT) system is highlighted in this paper. The design approach is detailed for meeting a specified set of instrument performance goals tailored towards experimental versatility and high resolution imaging. The XCT tool is unique in the detector and X-ray source design configuration, enabling control in the balance between detection efficiency and spatial resolution. The system package is also unique: The sample manipulation approach implemented enables a wide gamut of in situ experimentation to analyze structure evolution under applied stimulus, by optimizing scan conditions through a high degree of controllability. The component selection and design process is detailed: Incorporated components are specified, custom designs are shared, and the approach for their integration into a fully functional XCT scanner is provided. Custom designs discussed include the dual-target X-ray source cradle which maintains position and trajectory of the beam between the two X-ray target configurations with respect to a scintillator mounting and positioning assembly and the imaging sensor, as well as a novel large-format X-ray detector with enhanced adaptability. The instrument is discussed from an operational point of view, including the details of data acquisition and processing implemented for 3D imaging via micro-CT. The performance of the instrument is demonstrated on a silica-glass particle/hydroxyl-terminated-polybutadiene (HTPB) matrix binder PBX simulant. Post-scan data processing, specifically segmentation of the sample's relevant microstructure from the 3D reconstruction, is provided to demonstrate the utility of the instrument. - Highlights: • Custom built X-ray tomography system for microstructural characterization • Detector design for maximizing polychromatic X-ray detection efficiency • X-ray design offered for maximizing X-ray flux with respect to imaging resolution • Novel lab-scale XCT data acquisition and data processing methods • 3D characterization of glass-bead mock plastic-bonded-explosive stimulant.

36 MATERIALS SCIENCE↗

Imaging and characterization of γ′ and γ″ nanoparticles in Inconel 718 by EDX elemental mapping and FIB–SEM tomography

Microstructural characterization of Inconel 718 superalloy after three different heat treatment variants was performed by electron microscopy and electron tomography techniques, taking advantage of recent development in quantitative electron microscopy. Distribution maps of the chemical elements, collected by ChemiSTEM™ EDX system, offer a clear contrast between γ′, γ″, and the γ matrix. It was found that the γ′ phase contains mainly Ni, Al, and Ti, while the γ″ phase contains Ni, Nb, and Ti. Thus application of the Al and Nb STEM–EDX elemental maps enables identification and size measurements of γ′ and γ″ nanoparticles. 3D morphology of γ′ and γ″ precipitates was examined by electron microscopy and FIB–SEM tomography. Employed methods revealed that in all three heat treatment variants the γ′ particles are almost spheroidal while the γ″ precipitates are mainly elongated-disc shaped. However, the precipitate sizes differed for each variant contributing to differences in the yield strength. Tomographic images were used for estimation of the volume fraction of the both strengthening phases. - Highlights: • ChemiSTEM™ EDX elemental maps bring a fast mean to differentiate γ′ and γ″ particles. • Such maps enable for the explicit size measurements of γ′ and γ″ nanoparticles. • Explicit γ′ and γ″ phases total volume fraction was measured employing FIB–SEM. • γ′/γ″ co-precipitates and sandwich-like γ′/γ″/γ′ particles were present. • HRSTEM-HAADF imaging revealed atomic columns of the γ′/γ″ co-precipitates.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Structural evolution and strain induced mixing in Cu–Co composites studied by transmission electron microscopy and atom probe tomography

A Cu–Co composite material is chosen as a model system to study structural evolution and phase formations during severe plastic deformation. The evolving microstructures as a function of the applied strain were characterized at the micro-, nano-, and atomic scale-levels by combining scanning electron microscopy and transmission electron microscopy including energy-filtered transmission electron microscopy and electron energy-loss spectroscopy. The amount of intermixing between the two phases at different strains was examined at the atomic scale using atom probe tomography as complimentary method. It is shown that Co particles are dissolved in the Cu matrix during severe plastic deformation to a remarkable extent and their size, number, and volume fraction were quantitatively determined during the deformation process. From the results, it can be concluded that supersaturated solid solutions up to 26 at.% Co in a fcc Cu–26 at.% Co alloy are obtained during deformation. However, the distribution of Co was found to be inhomogeneous even at the highest degree of investigated strain. - Highlights: • Structural evolution in a deformed Cu–Co composite is studied on all length scales. • Amount of intermixing is examined by atom-probe tomography. • Supersaturated solid solutions up to 26 at.% Co in Cu are observed.

36 MATERIALS SCIENCE↗

Three dimensional (3D) microstructure-based finite element modeling of Al-SiC nanolaminates using focused ion beam (FIB) tomography

Al-SiC nanolaminate composites show promise as high performance coating materials due to their combination of strength and toughness. Although a significant amount of modeling effort has been focused on materials with an idealized flat nanostructure, experimentally these materials exhibit complex undulating layer geometries. This work utilizes FIB tomography to characterize this nanostructure in 3D and finite element modeling to determine the effect that this complex structure has on the mechanical behavior of these materials. A sufficiently large volume was characterized such that a 1 × 2 μm micropillar could be generated from the dataset and compared directly to experimental results. The mechanical response from this nanostructure was then compared to pillar models using simplified structures with perfectly flat layers, layers with sinusoidal waviness, and layers with arc segment waviness. The arc segment based layer geometry showed the best agreement with the experimentally determined structure, indicating it would be the most appropriate geometry for future modeling efforts. - Highlights: •FIB tomography was used to determine the structure of an Al-SiC nanolaminate in 3D. •FEM was used to compare the deformation of the nanostructure to experimental results. •Idealized structures from literature were compared to the FIB determined structure. •Arc segment based structures approximated the FIB determined structure most closely.

36 MATERIALS SCIENCE↗

Direct comparison of Fe-Cr unmixing characterization by atom probe tomography and small angle scattering

The fine microstructure obtained by unmixing of a solid solution either by classical precipitation or spinodal decomposition is often characterized either by small angle scattering or atom probe tomography. This article shows that a common data analysis framework can be used to analyze data obtained from these two techniques. An example of the application of this common analysis is given for characterization of the unmixing of the Fe-Cr matrix of a 15-5 PH stainless steel during long-term ageing at 350 °C and 400 °C. A direct comparison of the Cr composition fluctuations amplitudes and characteristic lengths obtained with both techniques is made showing a quantitative agreement for the fluctuation amplitudes. The origin of the discrepancy remaining for the characteristic lengths is discussed. - Highlights: •Common analysis framework for atom probe tomography and small angle scattering •Comparison of same microstructural characteristics obtained using both techniques •Good correlation of Cr composition fluctuations amplitudes from both techniques •Good correlation of Cr composition fluctuations amplitudes with classic V parameter.

36 MATERIALS SCIENCE↗

X-ray micro computed tomography characterization of cellular SiC foams for their applications in chemical engineering

Open-cell SiC foams clearly are promising materials for continuous-flow chemical applications such as heterogeneous catalysis and distillation. X-ray micro computed tomography characterization of cellular β-SiC foams at a spatial voxel size of 13.6{sup 3} μm{sup 3} and the interpretation of morphological properties of SiC open-cell foams with implications to their transport properties are presented. Static liquid hold-up in SiC foams was investigated through in-situ draining experiments for the first time using the μ-CT technique providing thorough 3D information about the amount and distribution of liquid hold-up inside the foam. This will enable better modeling and design of structured reactors based on SiC foams in the future. In order to see more practical uses, μ-CT data of cellular foams must be exploited to optimize the design of the morphology of foams for a specific application. - Highlights: •Characterization of SiC foams using novel X-ray micro computed tomography. •Interpretation of structural properties of SiC foams regarding to their transport properties. •Static liquid hold-up analysis of SiC foams through in-situ draining experiments.

36 MATERIALS SCIENCE↗

Study on the morphology of bulk hydrides by synchrotron X-ray tomography

Highlights: • The first DCT measurements in zirconium using high energy X-rays is shown. • A modified Hough Transform algorithm brings orientation calculation to pixel level. • The hydride plate normals are clustered in the {0002} pole direction. - Abstract: The morphologies of hydrides was studied using synchrotron X-ray at the European Synchrotron Radiation Facility (ESRF) using Diffraction Contrast Tomography (DCT). Diffraction Contrast Tomography is a relatively new technique that uses simultaneous collection of tomographic and diffraction data to reconstruct the 3D microstructural volume; in this case precipitates and matrix grains, while providing crystallographic orientation of neighbouring matrix grains. Previously the method was limited to light metals such as Al or Mg (due to the use of 8–30 keV X-rays). Here we show the first DCT measurements in a high atomic number metal zirconium using high energy X-rays (60 keV).

36 MATERIALS SCIENCE↗

Gaussian kernel density functions for compositional quantification in atom probe tomography

Highlights: • A methodology for compositional quantification from atom probe tomography is proposed. • A probability density function p(x) given discrete data points is constructed. • Each atom approximated by a Gaussian function with a particular smoothing parameter. • Density Kernel functions are used to find the optimum smoothing parameter. • The method is validated by using simulated data of semiconductor materials. - Abstract: Atom probe tomography (APT) has the ability to identify the nature and position of single atoms in a material with an almost 3D atomic resolution. However, the quantification of the material composition requires an appropriate treatment of the discrete APT data. When the amount of atoms selected to quantify the composition is relatively small, the spatial resolution is enhanced but the statistical error worsens. Conversely, the increase in the number of atoms considered reduces the spatial resolution, but improving the statistics. We have developed a methodology to reach an optimum equilibrium between the positional and the statistical error in an unsupervised form using Gaussian Kernel density functions. The validity of the method has been tested using APT simulated data of semiconductor materials. It has been proved that the chemical quantification in these materials requires the appropriate selection of the smoothing parameter, obtained without user intervention. In addition, the results have been compared to the usual techniques for composition measurement from APT data (voxelization and proximity histograms), showing better precision for high spatial resolution. This work supplies a data driven methodology based in Gaussian Kernel density functions for the accurate quantification of the composition from APT data.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Characterizing nanoscale precipitation in a titanium alloy by laser-assisted atom probe tomography

Highlights: • Atom-probe tomography was performed on Ti-5Al-5Mo-5V-3Cr wt% after quenching and 300 °C aging. • Isothermal ω phase was identified as Ti-rich and solute depleted after 1 h of aging. • The ω precipitate/matrix interface is O enriched. This may facilitate α formation. • High laser-pulse energies increase the probability of complex ion formation, complicating analysis. • Discrepancies between data from the LEAP 5000 XS and LEAP 4000X Si are discussed. - Abstract: Atom-probe tomography was performed on the metastable β-Ti alloy, Ti-5Al-5Mo-5V-3Cr wt% (Ti-5553), aged at 300 °C for 0 to 8 h, to precipitate the embrittling isothermal ω phase. Accurate precipitate quantification requires monitoring and controlling suitable charge-state ratios in the mass spectrum, which in turn are closely related to the laser pulse energy used. High ultraviolet laser pulse energies result in significant complex molecular ion formation during field-evaporation, causing mass spectral peak overlaps that inherently complicate data analyses. Observations and accurate quantification of the ω-phase under such conditions are difficult. The effect is minimized or eliminated by using smaller laser pulse energies. With a small laser pulse energy, Ti-rich and solute depleted precipitates of the isothermal ω phase with an oxygen enriched interface are observed as early as after 1 h aging time utilizing the LEAP 5000X S (77% detection efficiency). We note that these precipitates were not detected below a 2 h aging time with the LEAP 4000X Si (58% detection efficiency). The results are compared to the archival literature. The Al concentration in the matrix/precipitate interfacial region increases during aging. Nucleation of the α-phase at longer aging times may be facilitated by the O and Al enrichment at the matrix/precipitate interface (both strong α-stabilisers). The kinetics and compositional trajectory of the ω-phase with aging time are quantified, facilitating direct correlation of the APT data to previously published mechanical testing.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Validation of an alloy design strategy for stable Fe–Cr–Al–Nb-X ferritic alloys using electron microscopy and atom probe tomography

The Fe–Cr–Al–Nb ferritic alloys strengthened by A₂B Laves phases, with superior oxidation and corrosion resistance, are being considered for high temperature operation within fossil-fired steam power plants to increase process efficiency and reduce CO₂ emissions. In this paper, new sets of alloys based on Fe–30Cr–3Al–1Nb (in weight percent) were designed with (i) a high microstructural stability of Laves phase precipitates in a BCC-Fe matrix and (ii) reduced precipitate free zones along the grain boundaries, targeting an operating temperature of 700 °C. Two alloys with titanium or tungsten additions were down-selected through thermodynamic calculations with a design strategy to maximize the amount of Laves phase at 700 °C and lower the BCC solvus temperature. To validate this design strategy, the candidate alloys were cast, heat treated and aged at 700 °C, and the resulting microstructure was characterized using scanning electron microscopy and atom probe tomography. The alloys with titanium addition (1 wt%) showed monotonic precipitate coarsening. On the other hand, the alloys with tungsten addition (6 wt%) showed a reduced coarsening rate of Laves phase precipitates in the matrix up to 1008 h aging, whereas an acceleration of the precipitate coarsening after that. Atom probe tomography of this alloy revealed the formation of a core-shell precipitate structure with a Nb/Si rich core and W-rich shell, while the alloy with Ti-addition did not show the core-shell structure. The detailed characterization results revealed that the core-shell structure was strongly correlated with the observed two-step coarsening mode in the tungsten containing alloy.

36 MATERIALS SCIENCE↗

Investigation of the fatigue crack behavior of 304 stainless steels using synchrotron X-ray tomography and diffraction: Influence of the martensite fraction and role of inclusions

Here, the effect of fatigue on the microstructure of four-point bend specimens of three variations of 304 stainless steels (Commercial 304, 304H, and 304 L) was investigated using synchrotron x-ray tomography and diffraction. X-ray tomography revealed the formation of the fatigue-induced microvoids and crack while the diffraction data was used to quantify the amount of deformation-induced martensite found after fatigue in all samples. Transmission electron microscopy evidenced the role of the precipitates/inclusions on the microvoid formation. It was found to depend on their chemical nature. The shape of the precipitates/inclusions was also found to have an effect on the microvoid shape.

304 stainless steel↗

Mechanism of chlorine-induced stress corrosion cracking of two 304 SS heats in simulated marine environment through in situ X-ray tomography and diffraction: Role of deformation induced martensite and crack branching

In this work, In-situ synchrotron x-ray tomography and diffraction experiments were conducted on two heats of 304SS undergoing chlorine-induced stress-corrosion-cracking (CISCC) in a simulated marine environment. The role of deformation induced martensite on CISCC was investigated through diffraction analysis where no significant amount of martensite was found to form during CISCC, indicating that it may not play a significant role in affecting the process. Tomography combined with stress-intensity analysis revealed the influence of stress-intensity on branching types with single crack growth, micro-branching, and macro-branching. Post experimental electron microscopy characterization revealed the presence of FeCl 2 , CrCl 2 , and NiCl 2 ·6H 2 O compounds at the crack, which infers a dissolution mechanism during the experiment. A dissolution mechanism highlighting the synergy between stress and corrosion was proposed to explain chlorine-induced stress-corrosion-cracking and crack branching.

36 MATERIALS SCIENCE↗

A quantitative assessment of volumetric and anatomic changes of the parotid gland during intensity-modulated radiotherapy for head and neck cancer using serial computed tomography

To evaluate the change in volume and movement of the parotid gland measured by serial contrast-enhanced computed tomography scans in patients with head and neck cancer treated with parotid-sparing intensity-modulated radiotherapy (IMRT). A prospective study was performed on 13 patients with head and neck cancer undergoing dose-painted IMRT to 69.96 Gy in 33 fractions. Serial computed tomography scans were performed at baseline, weeks 2, 4, and 6 of radiotherapy (RT), and at 6 weeks post-RT. The parotid volume was contoured at each scan, and the movement of the medial and lateral borders was measured. The patient's body weight was recorded at each corresponding week during RT. Regression analyses were performed to ascertain the rate of change during treatment as a percent change per fraction in parotid volume and distance relative to baseline. The mean parotid volume decreased by 37.3% from baseline to week 6 of RT. The overall rate of change in parotid volume during RT was−1.30% per fraction (−1.67% and−0.91% per fraction in≥31 Gy and<31 Gy mean planned parotid dose groups, respectively, p = 0.0004). The movement of parotid borders was greater in the≥31 Gy mean parotid dose group compared with the<31 Gy group (0.22% per fraction and 0.14% per fraction for the lateral border and 0.19% per fraction and 0.06% per fraction for the medial border, respectively). The median change in body weight was−7.4% (range, 0.75% to−17.5%) during RT. A positive correlation was noted between change in body weight and parotid volume during the course of RT (Spearman correlation coefficient, r = 0.66, p<0.01). Head and neck IMRT results in a volume loss of the parotid gland, which is related to the planned parotid dose, and the patient's weight loss during RT.

61 RADIATION PROTECTION AND DOSIMETRY↗

A study on planning organ at risk volume for the rectum using cone beam computed tomography in the treatment of prostate cancer

In this study, we analyzed planning organ at risk volume (PRV) for the rectum using a series of cone beam computed tomographies (CBCTs) acquired during the treatment of prostate cancer and evaluated the dosimetric effect of different PRV definitions. Overall, 21 patients with prostate cancer were treated radically with 78 Gy in 39 fractions had in total 418 CBCTs, each acquired at the end of the first 5 fractions and then every alternate fraction. The PRV was generated from the Boolean sum volume of the rectum obtained from first 5 fractions (PRV-CBCT-5) and from all CBCTs (PRV-CBCT-All). The PRV margin was compared at the superior, middle, and inferior slices of the contoured rectum to compare PRV-CBCT-5 and PRV-CBCT-All. We also compared the dose received by the planned rectum (Rectum-computed tomography [CT]), PRV-CBCT-5, PRV-CBCT-All, and average rectum (CBCT-AV-dose-volume histogram [DVH]) at critical dose levels. The average measured rectal volume for all 21 patients for Rectum-CT, PRV-CBCT-5, and PRV-CBCT-All was 44.3 ± 15.0, 92.8 ± 40.40, and 121.5 ± 36.7 cm{sup 3}, respectively. For PRV-CBCT-All, the mean ± standard deviation displacement in the anterior, posterior, right, and left lateral directions in centimeters was 2.1 ± 1.1, 0.9 ± 0.5, 0.9 ± 0.8, and 1.1 ± 0.7 for the superior rectum; 0.8 ± 0.5, 1.1 ± 0.5, 1.0 ± 0.5, and 1.0 ± 0.5 for the middle rectum; and 0.3 ± 0.3; 0.9 ± 0.5; 0.4 ± 0.2, and 0.5 ± 0.3 for the inferior rectum, respectively. The first 5 CBCTs did not predict the PRV for individual patients. Our study shows that the PRV margin is different for superior, middle, and the inferior parts of the rectum, it is wider superiorly and narrower inferiorly. A uniform PRV margin does not represent the actual rectal variations during treatment for all treatment fractions. The large variation in interpatient rectal size implies a potential role for adaptive radiotherapy for prostate cancer.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A review of setup error in supine breast radiotherapy using cone-beam computed tomography

Setup error in breast radiotherapy (RT) measured with 3-dimensional cone-beam computed tomography (CBCT) is becoming more common. The purpose of this study is to review the literature relating to the magnitude of setup error in breast RT measured with CBCT. The different methods of image registration between CBCT and planning computed tomography (CT) scan were also explored. A literature search, not limited by date, was conducted using Medline and Google Scholar with the following key words: breast cancer, RT, setup error, and CBCT. This review includes studies that reported on systematic and random errors, and the methods used when registering CBCT scans with planning CT scan. A total of 11 relevant studies were identified for inclusion in this review. The average magnitude of error is generally less than 5 mm across a number of studies reviewed. The common registration methods used when registering CBCT scans with planning CT scan are based on bony anatomy, soft tissue, and surgical clips. No clear relationships between the setup errors detected and methods of registration were observed from this review. Further studies are needed to assess the benefit of CBCT over electronic portal image, as CBCT remains unproven to be of wide benefit in breast RT.

61 RADIATION PROTECTION AND DOSIMETRY↗