Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Time resolved imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

Chandra Observations of the Anomalous X-ray Pulsar 4U 0142+61

We present X-ray imaging, timing, and phase resolved spectroscopy of the anomalous X-ray pulsar 4U 0142+61 using the Chandra X-ray Observatory. The spectrum is well described by a power law plus blackbody model with Gamma = 3.35(2), kT=0.458(3) keV, and N-H = 0.91(2) x 10(exp 22)/sq cm); we find no significant evidence for spectral features (0.5 - 7.0 keV). Time resolved X-ray spectroscopy shows evidence for evolution in phase in either Gamma, or kT or some combination thereof as a function of pulse phase. We derive a precise X-ray position for the source and determine its spin period, P=8.68866(30) s. We have detected emission beyond 4 arcsec from the central source and extending beyond 100 arcsec, likely due to dust scattering in the interstellar medium.

Patel, Sandeep K.↗

The Focal Surface of the JEM-EUSO Telescope

Extreme Universe Space Observatory onboard JEM/EP (JEM-EUSO) is a space mission to study extremely high-energy cosmic rays. The JEM-EUSO instrument is a wide-angle refractive telescope in near-ultraviolet wavelength region to observe time-resolved atmospheric fluorescence images of the extensive air showers from the International Space Station. The focal surface is a spherical curved surface, and its area amounts to about 4.5 square m. The focal surface detector is covered with about 6,000 multi-anode photomultipliers (MAPMTs). The focal surface detector consists of Photo-Detector-Modules, each of which consists of 9 Elementary Cells (ECs). The EC contains 4 units of the MAPMTs. Therefore, about 1,500 ECs or about 160 PDMS are arranged on the whole of the focal surface of JEM- EUSO. The EC is a basic unit of the front-end electronics. The PDM is a, basic unit of the data acquisition system

Kawasaki, Yoshiya↗

Multi-Frame X-Ray Imaging Using a Streak Camera with a Patterned Photocathode, LAO-008-16, Year 1 of 2

Presentation describes development of a new time-resolved x-ray imaging system based on compressed ultrafast photography (CUP) to achieve multi-frame imaging for energies in the 1–10 keV range with a frame rate between 1 to 10 frames per nanosecond depending on the sweep time. A patterned gold photocathode was constructed for use with an existing Kentech x-ray streak camera. Significant work in reconstruction algorithms was performed to enable reconstructions of data that are much less sparse. These algorithms were tested with optical streak camera CUP data acquired at Livermore Operations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Study of instability formation and EUV emission in thin liners driven with a compact 250 kA, 150 ns linear transformer driver

A compact linear transformer driver, capable of producing 250 kA in 150 ns, was used to study instability formation on the surface of thin liners. In the experiments, two different materials, Cu and Ni, were used to study the effect of the liner's resistivity on formation and evolution of the instabilities. The dimensions of the liners used were 7 mm height, 1 mm radius, and 3 μm thickness. Laser probing and time resolved extreme ultraviolet (EUV) imaging were implemented to diagnose instability formation and growth. Time-integrated EUV spectroscopy was used to study plasma temperature and density. A constant expansion rate for the liners was observed, with similar values for both materials. Noticeable differences were found between the Cu and Ni instability growth rates. The most significant perturbation in Cu rapidly grows and saturates reaching a limiting wavelength of the order of the liner radius, while the most significant wavelength in Ni increases slowly before saturating, also at a wavelength close to the liner radius. Evidence suggests that the instability observed is the well-known m = 0 MHD instability. However, upon comparing the instability evolution of Cu and Ni, the importance of the resistivity on the seeding mechanism becomes evident. A comparison of end-on and side-on EUV emission possible indicates the formation of precursor plasma, where it has been estimated using EUV spectroscopy that the precursor plasma temperature is approximately 40 eV with ion density of order 10{sup 19} cm{sup −3}, for both materials.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Crystal response measurement of the x-ray transmission crystals used by the Imaging Spectroscopy Snout at the National Ignition Facility

The Imaging Spectroscopy Snout (ISS) used at the National Ignition Facility is able to simultaneously collect neutron pinhole images, 1D spatially resolved x-ray spectra, and time resolved x-ray pinhole images. To measure the x-ray spectra, the ISS can be equipped with up to four different transmission crystals, each offering different energy ranges from ∼7.5 to ∼12 keV and different resolutions. Characterizing and calibrating such instruments is of paramount importance in order to extract meaningful results from experiments. More specifically, we characterized different ISS transmission-type alpha-Quartz crystals by measuring their responses as a function of photon energy, from which we inferred the angle-integrated reflectivity for each crystal’s working reflections. These measurements were made at the Lawrence Livermore National Laboratory calibration station dedicated to the characterization of x-ray spectrometers. The sources used covered a wide x-ray range—from a few to 30 keV; the source diameter was ∼0.6 mm. The experimental results are discussed alongside theoretical calculations using the pyTTE model.

Dozieres, M. (ORCID:0000000286401459)↗

National Opacity Program: Analysis of Opacity-relevant X-ray Emission Spectra (Milestone Report ID 7121)

We have produced high energy density iron plasmas at temperatures above 1 keV and electron densities exceeding 1023 cm -3 (~ 1 g/cm 3 ) using the Orion laser at the Atomic Weapons Establishment. These plasmas were created by irradiating 50 µm diameter layered targets with frequency doubled (λ = 527 nm), 1 ps laser pulses focused to a 100 µm diameter producing an irradiance of ~ 2 x 10 18 W/cm 2 . The buried layer targets consist of 160 nm iron sulfide (FeS), 60 nm potassium chloride (KCl), and 15 nm carbon. The combined layers are tamped on both sides with 3 µm of parylene-N. The x-ray emission from the plasma was measured using two time-resolved, and four time-integrated Bragg crystal spectrometers, as well as one time-integrated imaging system. One time-resolved x-ray spectrometer measured emission from L-shell transitions in highly charged iron, the other from K-shell transitions in helium-like S 14+ and hydrogen-like S 15+ . The time-integrated spectrometers are intensity-calibrated and measured emission from K-shell transitions in sulfur, potassium, chlorine, and both K-shell and L-shell transitions in iron. The density and temperature of the plasma were determined by modeling the x-ray spectra using different spectral and hydrodynamic modeling packages. A brief overview of the uncertainties associated with the measurements and models are presented. We also give an overview of our 1-D HYDRA-DCA radiation-hydrodynamics model and improvements for future work. Our results aid in assessing experimental uncertainties associated with plasma uniformity and with x-ray emission employed as diagnostics in opacity experiments at temperatures and densities not achievable elsewhere and represent a significant step in creating and diagnosing plasmas near LTE. These results are summarized as part of the completion requirements for milestone 7121

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Direct imaging of electron recombination and transport on a semiconductor surface by femtosecond time-resolved photoemission electron microscopy

Much effort has been devoted to the development of techniques to probe carrier dynamics, which govern many semiconductor device characteristics. We report direct imaging of electron dynamics on semiconductor surfaces by time-resolved photoemission electron microscopy using femtosecond laser pulses. The experiments utilized a variable-repetition-rate femtosecond laser system to suppress sample charging problems. The recombination of photogenerated electrons and the lateral motion of the electrons driven by an external electric field on a GaAs surface were visualized. The mobility was estimated from a linear relationship between the drift velocity and the potential gradient.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Resolving dynamics of cell signaling via real-time imaging of the immunological synapse.

This highly interdisciplinary team has developed dual-color, total internal reflection microscopy (TIRF-M) methods that enable us to optically detect and track in real time protein migration and clustering at membrane interfaces. By coupling TIRF-M with advanced analysis techniques (image correlation spectroscopy, single particle tracking) we have captured subtle changes in membrane organization that characterize immune responses. We have used this approach to elucidate the initial stages of cell activation in the IgE signaling network of mast cells and the Toll-like receptor (TLR-4) response in macrophages stimulated by bacteria. To help interpret these measurements, we have undertaken a computational modeling effort to connect the protein motion and lipid interactions. This work provides a deeper understanding of the initial stages of cellular response to external agents, including dynamics of interaction of key components in the signaling network at the 'immunological synapse,' the contact region of the cell and its adversary.

59 BASIC BIOLOGICAL SCIENCES↗

Single- and multi-photon-induced ultraviolet excitation and photodissociation of CH 3 I probed by coincident ion momentum imaging

The UV-induced photodissociation dynamics of iodomethane (CH 3 I) in its A-band are investigated by time-resolved coincident ion momentum imaging using strong-field ionization as a probe. The delay-dependent kinetic energy distribution of the photofragments resulting from double ionization of the molecule maps the cleavage of the carbon–iodine bond and shows how the existence of a potential well in the di-cationic potential energy surfaces shapes the observed distribution at small pump–probe delays. Furthermore, the competition between single- and multi-photon excitation and ionization of the molecule is studied as a function of the intensity of the UV-pump laser pulse. Two-photon excitation to Rydberg states is identified by tracking the transformation of the delay-dependent singly-charged iodomethane yield from a pure Gaussian distribution at low intensity to a Gaussian with an exponentially decaying tail at higher intensities. In conclusion, dissociative ionization induced by absorption of three UV photons is resolved as an additional delay-dependent feature in the kinetic energy of the fragment ions detected in coincidence.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Synchronized multiartifact reduction with tomographic reconstruction (SMART-RECON): A statistical model based iterative image reconstruction method to eliminate limited-view artifacts and to mitigate the temporal-average artifacts in time-resolved CT

Purpose: In x-ray computed tomography (CT), a violation of the Tuy data sufficiency condition leads to limited-view artifacts. In some applications, it is desirable to use data corresponding to a narrow temporal window to reconstruct images with reduced temporal-average artifacts. However, the need to reduce temporal-average artifacts in practice may result in a violation of the Tuy condition and thus undesirable limited-view artifacts. In this paper, the authors present a new iterative reconstruction method, synchronized multiartifact reduction with tomographic reconstruction (SMART-RECON), to eliminate limited-view artifacts using data acquired within an ultranarrow temporal window that severely violates the Tuy condition. Methods: In time-resolved contrast enhanced CT acquisitions, image contrast dynamically changes during data acquisition. Each image reconstructed from data acquired in a given temporal window represents one time frame and can be denoted as an image vector. Conventionally, each individual time frame is reconstructed independently. In this paper, all image frames are grouped into a spatial–temporal image matrix and are reconstructed together. Rather than the spatial and/or temporal smoothing regularizers commonly used in iterative image reconstruction, the nuclear norm of the spatial–temporal image matrix is used in SMART-RECON to regularize the reconstruction of all image time frames. This regularizer exploits the low-dimensional structure of the spatial–temporal image matrix to mitigate limited-view artifacts when an ultranarrow temporal window is desired in some applications to reduce temporal-average artifacts. Both numerical simulations in two dimensional image slices with known ground truth and in vivo human subject data acquired in a contrast enhanced cone beam CT exam have been used to validate the proposed SMART-RECON algorithm and to demonstrate the initial performance of the algorithm. Reconstruction errors and temporal fidelity of the reconstructed images were quantified using the relative root mean square error (rRMSE) and the universal quality index (UQI) in numerical simulations. The performance of the SMART-RECON algorithm was compared with that of the prior image constrained compressed sensing (PICCS) reconstruction quantitatively in simulations and qualitatively in human subject exam. Results: In numerical simulations, the 240{sup ∘} short scan angular span was divided into four consecutive 60{sup ∘} angular subsectors. SMART-RECON enables four high temporal fidelity images without limited-view artifacts. The average rRMSE is 16% and UQIs are 0.96 and 0.95 for the two local regions of interest, respectively. In contrast, the corresponding average rRMSE and UQIs are 25%, 0.78, and 0.81, respectively, for the PICCS reconstruction. Note that only one filtered backprojection image can be reconstructed from the same data set with an average rRMSE and UQIs are 45%, 0.71, and 0.79, respectively, to benchmark reconstruction accuracies. For in vivo contrast enhanced cone beam CT data acquired from a short scan angular span of 200{sup ∘}, three 66{sup ∘} angular subsectors were used in SMART-RECON. The results demonstrated clear contrast difference in three SMART-RECON reconstructed image volumes without limited-view artifacts. In contrast, for the same angular sectors, PICCS cannot reconstruct images without limited-view artifacts and with clear contrast difference in three reconstructed image volumes. Conclusions: In time-resolved CT, the proposed SMART-RECON method provides a new method to eliminate limited-view artifacts using data acquired in an ultranarrow temporal window, which corresponds to approximately 60{sup ∘} angular subsectors.

60 APPLIED LIFE SCIENCES↗

Coulomb-explosion imaging of concurrent CH 2 BrI photodissociation dynamics

The dynamics following laser-induced molecular photodissociation of gas-phase CH 2 BrI at 271.6 nm were investigated by time-resolved Coulomb-explosion imaging using intense near-IR femtosecond laser pulses. Furthermore, the observed delay-dependent photofragment momenta reveal that CH 2 BrI undergoes C-I cleavage, depositing 65.6% of the available energy into internal product states, and that absorption of a second UV photon breaks the C-Br bond of CH 2 Br. Simulations confirm that this mechanism is consistent with previous data recorded at 248 nm, demonstrating the sensitivity of Coulomb-explosion imaging as a real-time probe of chemical dynamics.

74 ATOMIC AND MOLECULAR PHYSICS↗

Space-Charge Aberrations in Single-Shot Time-Resolved Transmission Electron Microscopy

In this paper, we discuss effects of space-charge fields on imaging performance in a single-shot time-resolved transmission electron microscope. Using a Green’s function perturbation method, we derive analytical estimates for the effects of space-charge nonlinearity on the image formation process and the associated aberration coefficients. The dependence of these coefficients on the initial beam phase space distribution is elucidated. The results are validated by particle tracking simulations and provide fundamental scaling laws for the trade-off between temporal and spatial resolutions in single-shot time-resolved transmission electron microscopy.

43 PARTICLE ACCELERATORS↗

IS ACTIVE REGION CORE VARIABILITY AGE DEPENDENT?

The presence of both steady and transient loops in active region cores has been reported from soft X-ray and extreme-ultraviolet observations of the solar corona. The relationship between the different loop populations, however, remains an open question. We present an investigation of the short-term variability of loops in the core of two active regions in the context of their long-term evolution. We take advantage of the nearly full Sun observations of STEREO and Solar Dynamics Observatory spacecraft to track these active regions as they rotate around the Sun multiple times. We then diagnose the variability of the active region cores at several instances of their lifetime using EIS/Hinode spectral capabilities. We inspect a broad range of temperatures, including for the first time spatially and temporally resolved images of Ca XIV and Ca XV lines. We find that the active region cores become fainter and steadier with time. The significant emission measure at high temperatures that is not correlated with a comparable increase at low temperatures suggests that high-frequency heating is viable. The presence, however, during the early stages, of an enhanced emission measure in the ''hot'' (3.0-4.5 MK) and ''cool'' (0.6-0.9 MK) components suggests that low-frequency heating also plays a significant role. Our results explain why there have been recent studies supporting both heating scenarios.

79 ASTRONOMY AND ASTROPHYSICS↗

An Optical Streak Diagnostic for Observing Anode-Cathode Plasmas for Radiographic Source Development

National Security Technologies, LLC, and Sandia National Laboratories are collaborating in the development of pulsed power–driven flash x-ray radiographic sources that utilize high-intensity electron beam diodes. The RITS 6 (Radiographic Integrated Test Stand) accelerator at Sandia is used to drive a self magnetic pinch diode to produce a Bremsstrahlung x-ray source. The high electric fields and current densities associated with these short A-K gap pinch beam diodes present many challenges in diode development. Plasmas generated at both the anode and cathode affect the diode performance, which is manifested in varying spot (source) sizes, total dose output, and impedance profiles. Understanding the nature of these plasmas including closure rates and densities is important in modeling their behavior and providing insight into their mitigation. In this paper we describe a streak camera–based optical diagnostic that is capable of observing and measuring plasma evolution within the A-K gap. By imaging a region of interest onto the input slit of a streak camera, we are able to produce a time-resolved one-dimensional image of the evolving plasma. Typical data are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Absolute timing calibration of the Resolve microcalorimeter spectrometer on the X-ray Imaging and Spectroscopy Mission

The Resolve microcalorimeter spectrometer on the X-ray Imaging and Spectroscopy Mission (XRISM) is designed to have a good timing capability with the mission-level requirement of 1 ms as the absolute time tagging accuracy to suffice the needs for observatory science. In the ground calibration campaign, the absolute and relative timing offsets were measured using pulsed X-rays from the modulated X-ray sources. These offsets were used to determine calibration parameters, the Resolve timing coefficients, which are used in the offline correction of event times. In the orbit, reevaluation of the timing coefficients was carried out using the Crab pulsar, which was observed in two periods, one in the performance verification phase and the other in the guest observation phase. We report the absolute timing calibration of XRISM/Resolve using the ground and in-orbit data. Although the requirement is likely satisfied with the ground parameters, the timing coefficients have been refined using the in-orbit calibration to improve the timing accuracy. In addition, for the first time, we present the interpretation of the absolute timing offset originating from the analog and digital processing of X-ray events unique to a microcalorimeter spectrometer and present a complete view of the timing error of the Resolve instrument.

Astronomy and AstroPhysics↗

Atomic Resolution Coherent Diffractive Imaging and Ultrafast Science

A major scientific challenge is determining the 3-D atomic structure of small nanostructures, including single molecules. Coherent diffractive imaging (CDI) is a promising approach. Recent progress has demonstrated coherent diffraction patterns can be recorded from individual nanostructures and phased to reconstruct their structure. However, overcoming the dose limit imposed by radiation damage is a major obstacle toward the full potential of CDI. One approach is to use ultrafast x-ray or electron pulses. In electron diffraction, amplitudes recorded in a diffraction pattern are unperturbed by lens aberrations, defocus, and other microscope resolution-limiting factors. Sub-A signals are available beyond the information limit of direct imaging. Significant contrast improvement is obtained compared to high-resolution electron micrographs. progress has also been made in developing time-resolved electron diffraction and imaging for the study of ultrafast dynamic processes in materials. This talk will cover these crosscutting issues and the convergence of electron and x-ray diffraction techniques toward structure determination of single molecules.

74 ATOMIC AND MOLECULAR PHYSICS↗

Imaging transient molecular configurations in UV-excited diiodomethane

Femtosecond structural dynamics of diiodomethane (CH 2 I 2 ) triggered by ultraviolet (UV) photoabsorption at 290 and 330 nm are studied using time-resolved coincident Coulomb explosion imaging driven by a near-infrared probe pulse. Here, we map the dominant single-photon process, the cleavage of the carbon–iodine bond producing rotationally excited CH 2 I radical, identify the contributions of the three-body (CH 2 + I + I) dissociation and molecular iodine formation channels, which are primarily driven by the absorption of more than one UV photon, and demonstrate the existence of a weak reaction pathway involving the formation of short-lived transient species resembling iso-CH 2 I 2 -like geometries with a slightly shorter I–I separation compared to the ground-state CH 2 I 2 . These transient molecular configurations, which can be separated from the other channels by applying a set of conditions on the correlated momenta of three ionic fragments, are formed within ∼100 fs after the initial photoexcitation and decay within the next 100 fs.

Atomic and molecular processes↗