Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Testing.”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

Foreword Special issue on the Kilopower Project, Kilowatt Reactor Using Stirling TechnologY (KRUSTY) Test

This special issue of Nuclear Technology contains full-length, peer-reviewed papers describing the design work leading up to and the results of the Kilowatt Reactor Using Stirling TechnologY (KRUSTY) test. KRUSTY was the centerpiece of the National Aeronautics and Space Administration (NASA) Kilopower Project to design, build, and test a space nuclear reactor. This test was the first such test since the end of the Space Nuclear Auxiliary Power (SNAP) project at the end of the 1960s. In this issue, the introduction paper presents the goals of the Kilopower Project and the potential missions this reactor concept could serve in NASA. Kilopower was intended to serve both human exploration needs on planetary surfaces as well as science needs for deep-space exploration. The design work for the experiment by Poston and the power conversion development by Gibson present the pre-work required to perform the eventual KRUSTY test. A paper on regulatory analysis follows, to show the path used to gain approval of the proposed experiment. Then, the early zero-power critical experiments are presented by Sanchez and Grove. These experiments were essential data used to enhance model predictions prior to the high-temperature test. Next, Poston presents the three experiments (warm criticals) that increase the temperature in an incremental fashion prior to the final experiment. These experiments were used to achieve final regulatory approval of the final high-temperature experiment. The last paper by Poston presents the results of the steady-state and transient testing of the reactor at full power and at the design temperature. These results show that the reactor design and as-built experiment met all of the requirements that NASA had developed for the system. Any experiment of this magnitude was accomplished only because of the hard work and dedication of a large number of people at multiple institutions, including the NASA Glenn Research Center, NASA Marshall Space Flight Center, Y-12 National Security Site, Los Alamos National Laboratory, and the Nevada National Security Site prime contractor (formerly National Security Technologies and now the Mission Support and Test Services). The project was jointly funded by the Space Technology Mission Directorate at NASA and the Criticality Safety Program at the National Nuclear Security Administration (NNSA). A special thanks to Jerry McKamy and Angela Chambers at the NNSA and Lee Mason and Don Palac at NASA for their support and guidance. For the authors and multitude of staff that performed this work, the passion for space nuclear reactors was the key to making this experiment a reality.

99 GENERAL AND MISCELLANEOUS↗

Code Benchmark of the HTTF Pressurized Conduction Cooldown Test Using SAM

The High Temperature Test Facility (HTTF) at Oregon State University is an integral system test facility to simulate postulated reactor transients of prismatic high-temperature gas-cooled reactors(HTGRs). A series of test campaigns was launched, providing abundant test data that could be used to benchmark reactor system analysis codes like the System Analysis Module (SAM). In this study, a SAM model of the facility is developed based on the two-dimensional (2D) ring model approach. All components including the ceramic matrix, graphite heaters, helium coolant channels, core barrel, upcomer, pressure vessel, and reactor cavity cooling system are modeled as concentric cylindrical rings. The model is used to simulate one of the benchmark problems-Pressurized Conduction Cooldown (PCC)-within the scope of the Organisation for Economic Co-operation and Development Nuclear Energy Agency International HTTF Benchmark. The simulations consist of two parts. In the first part, operating and boundary conditions as well as thermophysical properties of materials are specified for the benchmark problem. In this work, results from the first part will be used in code-to-code comparison. In the second part, the SAM model is used to simulate Test PG-27, which is the first PCC test carried out in the HTTF, with only two of the ten heater banks activated. The results in the second part are used for code-to-data comparison. Because the helium coolant flow rate is not measured in this facility, it is estimated using the input power and inlet/outlet coolant temperatures. Additionally, radial heat flow in the ceramic blocks is complicated by hundreds of cylindrical coolant channels and heater rods embedded in them. As such, it is necessary to deduce an effective thermal conductivity for the ceramic to analyze the core thermal behavior. SAM predictions of the helium coolant and ceramic temperatures are compared with test data measured in three equivalent sectors. Overall, the SAM results agree reasonably well with test data within the variation of data among the three sectors, which demonstrates SAM's capability in capturing transient effects in HTGR using the simplified 2D ring model.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Update to the Microcontroller Benchmark for Radiation Testing

LANL developed a benchmark of software code for radiation testing of microprocessors several years ago, and it was published under an open-source license on GitHub. Publishing the software is necessary for other researchers to adopt and implement this benchmark for radiation testing of other microprocessors to standardize test practices so that test data can be compared across different microprocessors. The original codes have been used several times by other organizations to test a wide range of microcontrollers and microprocessors. After several years of research, LANL is ready to update the benchmark. Changes include: 1. Addition of new codes that allow common software codes to be tested, 2. Addition of new codes that instrument more microprocessor circuitry, 3. Addition of input patterns that allow for a more compressive understanding of how the memory layout affects the sensitivity to radiation-induced faults and better use of automated test pattern generation standards, and 4. Modification of current codes for faster and more resilient detection, reporting and correction of radiation-induced faults. These codes have been tested by LANL researchers over the last few years, which has been published in the open literature. As the code base for the new benchmarks are stable, it is time to release the update to the GitHub repository, where the original codes were released.

Quinn, Heather↗

In-situ thermomechanical measurements during burst testing of Zr claddings using digital image correlation and infrared thermography techniques

Burst testing has long been a relied-on method for assessing fuel cladding materials in light-water reactoraccident scenarios. However, burst testing historically provided minimal in-situ observations beyond a few thermocouple readings, pressure from transducers, and post-test deformation measurements. Acquisition of full cladding thermomechanical data throughout a burst test would be invaluable to fuel system qualification, material model development and fuel performance code validation, such as the BISON fuel performance code. Recently, methodologies for simultaneously applying 2-dimensional digital image correlation and infrared thermography techniques to quantify the relationship between temperature, internal cladding pressure, and deformation during burst testing were developed. This work details results from the application of these techniques to burst testing of Zircaloy-4 cladding segments subjected to loss-of-coolant accident transients in an air environment. Two types of tests were performed with: (a) cladding segments connected to a fixed pressure reservoir as well as (b) closed systems where internal pressure increased during transients. In-situ thermomechanical measurements including strain and thermal gradient data are presented, demonstrating the effectiveness of applying combined surface measurement techniques to burst testing

Bell, Sam↗

Validation and Recalibration of the Solubility Models in Support of the Heater Test in Salt Formations

The US Department of Energy Office of Nuclear Energy is conducting a brine availability heater test to characterize the thermal, mechanical, hydrological and chemical response of salt at elevated temperatures. In the heater test, brines will be collected and analyzed for chemical compositions. In order to support the geochemical modeling of chemical evolutions of the brines during the heater test, we are recalibrating and validating the solubility models for the mineral constituents in salt formations up to 100°C, based on the solubility data in multiple component systems as well as simple systems from literature. In this work, we systematically compare the model-predicted values based on the various solubility models related to the constituents of salt formations, with the experimental data. As halite is the dominant constituent in salt formations, we first test the halite solubility model in the Na-Mg-Cl dominated brines. We find the existing halite solubility model systematically over-predict the solubility of halite. We recalibrate the halite model, which can reproduce halite solubilities in Na-Mg-Cl dominated brines well. As gypsum/anhydrite in salt formations controls the sulfate concentrations in associated brines, we test the gypsum solubility model in NaCl solutions up to 5.87 mol•kg –1 from 25 ° C to 50 ° C. The testing shows that the current gypsum solubility model reproduces the experimental data well when NaCl concentrations are less than 1 mol•kg –1 . However, at NaCl concentrations higher than 1, the model systematically overpredicts the solubility of gypsum. In the Na + —Cl – —SO 4 2– —CO 3 2– system, the validation tests up to 100 ° C demonstrate that the model excellently reproduces the experimental data for the solution compositions equilibrated with one single phase such as halite (NaCl) or thenardite (Na 2 SO 4 ), with deviations equal to, or less than, 1.5 %. The model is much less ideal in reproducing the compositions in equilibrium with the assemblages of halite + thenardite, and of halite + thermonatrite (Na 2 CO 3 •H 2 O), with deviations up to 31 %. The high deviations from the experimental data for the multiple assemblages in this system at elevated temperatures may be attributed to the facts that the database has the Pitzer interaction parameters for Cl – —CO 3 2– and SO 4 2– —CO 3 2– only at 25 ° C. Finally, in the Na + —Ca 2+ —SO 4 2– —HCO 3 – system, the validation tests also demonstrate that the model reproduces the equilibrium compositions for one single phase such as gypsum better than the assemblages of more than one phase.

36 MATERIALS SCIENCE↗

The Effect of Prostate-Specific Antigen (PSA) Test on Radiation Risk Estimate for Prostate Cancer Incidence among Atomic-Bomb Survivors

Following our previous report on the radiation doseresponse for prostate cancer incidence rates in the Life Span Study (LSS) cohort of atomic bomb survivors, we reevaluated the radiation-related risk adjusting for differences in baseline cancer incidence rates among three subsets of the LSS cohort defined by the timing of their first participation in biennial health examinations offered to the Adult Health Study (AHS) sub-cohort members and prostate-specificantigen (PSA) testing status for AHS participants: 1. nonAHS participants, 2. AHS participants before receiving PSA test, and 3. AHS participants after receiving PSA test. We found a 2.9-fold increase in the baseline incidence rates among AHS participants after receiving PSA test. After adjusting for the PSA-testing-status effects on the baseline rates the estimated excess relative risk (ERR) per Gy was 0.54 (95% CI: 0.15, 1.05), which was almost identical to the previously reported unadjusted ERR estimate (0.57, 95% CI: 0.21, 1.00). The current results confirmed that, while the PSA testing among AHS participants increased the baseline incidence rates, it did not impact the radiation risk estimate, strengthening the previously reported dose-response relationship for prostate cancer incidence in the LSS. As the use of PSA tests continue in screening and medical settings, analyses of possible effects of PSA testing should be an important aspect of future epidemiological studies of the association between radiation exposure and prostate cancer.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Influence of Glycolate Anion on Aqueous Corrosion in DWPF and Downstream Facilities – SCC Testing

Glycolic acid is being evaluated as an alternate reductant in the preparation of High Level Waste for the Defense Waste Processing Facility (DWPF) at the Savannah River Site (SRS). During processing, the glycolic acid may not be completely consumed with small quantities of the glycolate anion being carried forward to waste facilities. The SRS liquid waste contractor requested an assessment of the influence of the glycolate anion on the corrosion of the materials of construction (MoC) throughout the waste processing system since this concern had not been previously evaluated. The influence of glycolic acid on the occurrence of stress corrosion cracking (SCC) had not been evaluated specifically in the previous testing. The present testing used electrochemical and coupon immersion testing to assess this influence. Additionally, the primary guidance on corrosion for operating DWPF with a formate-based flowsheet is based on testing that utilized test solutions with a small number of constituents. Recent testing used more complex solutions based on flowsheet development for DWPF. Additional electrochemical tests were also conducted to assess the influence of this difference on test results.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Of Clouds and Craters: The History of U.S. Nuclear Weapons Testing

“Now!” With that word, the Atomic Age – and the era of nuclear weapons testing – dawned. The advent of World War II’s first irresistible weapon, which had been secretly tested in the New Mexico desert in July 1945, would help hasten the inevitable: complete victory for the Allies. Codenamed Trinity, the test was the first of over a thousand conducted by the United States between 1945 and 1992. Nuclear weapons would change future clashes as well. The looming Cold War, with roots stretching all the way back to 1917, was history’s first conflict between two, major nations armed with nuclear weapons. It is clear the existence of those weapons played an important role in maintaining a tenuous peace between the United States and the Soviet Union; it is also clear nuclear weapons testing played a prominent role in fueling both the arms race and the success of deterrence. Yet, the history of nuclear weapons testing is rarely remembered, even though nuclear tests have been performed in the very recent past. Of the estimated 2,000-plus nuclear tests ever performed, the U.S. is responsible for approximately half. This is the story of U.S. full-scale nuclear weapons testing.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Analysis of Respirator Cartridge Performance Testing on Hanford Tank A-101

Washington River Protection Solutions (WRPS) conducted tests on two types of chemical cartridges for use in air purifying respirators (APR) to determine the period of time that the cartridges would provide adequate performance1 to protect workers when exposed to a mixture of Chemicals of Potential Concern (COPCs) from vapors emanating from the headspace of tank A-101 on the Hanford Site. The Occupational Safety and Health Administration (OSHA) identifies cartridge testing as a valid approach for establishing a cartridge change schedules.[3] Testing is commonly applied in situations where mixtures of COPCs exist, and where other approaches, such as manufacturer recommendations and modeling, are less reliable. The tests were designed and conducted to ensure measurement and/or control of the key variables OSHA identified as important to estimate cartridge service life, including temperature, humidity, COPC concentration, breathing rate, and cartridge adsorption capacity. Testing was conducted over a period from July 22-24, 2016, using headspace vapors from Hanford tank A-101 under static conditions2 fed to a respirator cartridge test stand developed by WRPS in collaboration with HiLine Engineering (Richland, Washington). Multipurpose respirator cartridges, SCOTT 7422-SD1 and 7422-SC1 (SCOTT Safety, Monroe, North Carolina) were assessed on separate days with A-101 headspace vapors. Sample media (sorbent tubes) were used to collect samples of the vapor stream entering and exiting the respirator cartridge, and were subsequently analyzed for COPC concentrations. Pacific Northwest National Laboratory was tasked with conducting an independent analysis of the analytical results and making recommendations based on the results for respiratory cartridge performance and service life. Key conclusions from the assessment of the 59 COPCs in this study are described below: • Based on d measured cartridge inlet vapor concentrations from tank A-101 headspace, both ammonia and N-Nitrosodimethylamine (NDMA) exceeded their Occupational Exposure Limits (OEL).3 These measurements were generally consistent with maximum A-101 headspace measurements previously obtained for these two compounds. • Ammonia had respirator cartridge outlet concentrations that exceeded 10% of the OEL for both cartridges tested, indicating breakthrough for each. For the SCOTT 7422-SD1 cartridge, ammonia appeared to breakthrough above 10% of its OEL after 2 hours. For the SCOTT 7422-SC1 cartridge, ammonia breakthrough appeared to occur after 8 hours. 1 “Adequate performance” refers to the breakthrough criteria used in this analysis—that is, sustained cartridge outlet concentrations above 10% of the OEL. For some COPCs, an alternate threshold has been applied when necessary due to higher detection limit (DL)/reporting limit (RL) values for specific compounds. Ultimately, Industrial Hygiene professionals will use these results along with specific hazard assessments to determine service life and cartridge use that provides the necessary performance. 2 These tests were conducted under static conditions absent waste-disturbing activities in the subject tank or tank farm. 3 Occupational Exposure Limits accepted for Hanford Tank Farm use are based on OELs established by a U.S. governmental agency or national professional organization (e.g., OSHA, National Institute for Occupational Safety and Health, American Conference of Governmental Industrial Hygienists), or if no U.S. OEL exists, standard toxicological practices are applied to develop OELs using non-U.S. exposure limits, other established OELs for chemical surrogates when available, or other standard procedures. The OEL for NDMA was established in 2005 based on the MAK (Maximale Arbeitsplatzkonzentration) Commission standard adopted in Europe. iv • Despite respirator inlet measurements for NDMA that were in excess of its OEL, all corresponding outlet measurements, from both respirator cartridges, were below analytical DL 1 for the

61 RADIATION PROTECTION AND DOSIMETRY↗

Hydraulic Testing of the Lost Lake Aquifer Near Recovery Well RWM019

An aquifer pumping test was conducted on the Lost Lake Aquifer Zone (LLAZ) at the recently installed recovery well RWM019 in accordance with the approved test plan (Dixon, 2020). The objective of the testing was to determine baseline well performance parameters and aquifer hydraulic conductivity. This testing consisted of a step-drawdown test to determine well performance properties, a constant pumping rate aquifer test to determine aquifer hydraulic properties, and a post-test aquifer recovery monitoring period also used to estimate aquifer hydraulic properties. Well performance parameters determined included specific capacity, well efficiency, and head loss coefficients. The specific capacity of RWM019 was determined to be approximately 2.6 gpm/ft of drawdown based on the final step of the step-drawdown test. Well efficiency was inversely related to pumping rate and decreased from 87% to 81% over a pumping range of approximately 49 to 79 gpm. The aquifer head loss coefficient was determined to be 2.3 ft/ft 3 /min and the well loss coefficient was determined to be 0.05 min 2 /ft 5 .

42 ENGINEERING↗

Creep, Fatigue, and Creep-Fatigue Testing of Alloy 709 Base Metal at ORNL (FY 2021)

The testing activities and research in support of ASME Code qualification of Alloy 709, an advanced austenitic steel, are being carried out at Oak Ridge National Laboratory (ORNL), Argonne National Laboratory, and Idaho National Laboratory. ORNL has been tasked to carry out a subset of the Code Case testing for creep rupture, fatigue and creep-fatigue. The focus of the FY 2021 Code Case testing on Alloy 709 base metal at ORNL includes (1) continuing the long-term creep rupture testing on ESR1100 and AOD1100; (2) adding ESR1150-AH to the creep Code Case testing matrix; and (3) continuing fatigue and creep-fatigue Code Case testing on ESR1150- AH. This report summarizes the status and the preliminary test results of FY 2021 planned Code Case testing at ORNL.

36 MATERIALS SCIENCE↗

Cesium Ion Exchange Testing Using Crystalline Silicotitanate with Hanford Tank Waste 241-AP-107

At the time of this testing, the Low-Activity Waste Pretreatment System (LAWPS) was to provide for the initial production of immobilized low-activity waste by feeding Hanford tank supernate from tank farms to the Hanford Tank Waste Treatment and Immobilization Plant (WTP) Low-Activity Waste (LAW) Facility for immobilization. Washington River Protection Solutions requested that Hanford tank waste collected from tank 241-AP-107 (hereafter called AP-107) be processed using conceived pretreatment steps (suspended solids removal by filtration, Cs removal by ion exchange) then vitrified. A small-scale test platform to demonstrate the solids filtration, Cs removal, and LAW vitrification was constructed and installed at Pacific Northwest National Laboratory. Bench-scale ion exchange testing with approximately 9 L of AP-107 supernate was conducted using crystalline silicotitanate (CST) ion exchange media. The IONSIV R9140-B CST was provided by Honeywell UOP, LLC in 2018 (Batch 2081000057). The ion exchange media was first tested with simulant and was previously described. This report describes the Cs ion exchange batch contact and column test results with the AP-107 tank waste. Batch contact testing helps to evaluate CST performance on tank waste supernate prior to processing it in the ion exchange columns. Batch contacts were performed with the waste at four Cs concentrations at a phase ratio of 200 (liquid volume to exchanger mass) with AP-107. The distribution coefficient (K d ) at the equilibrium condition of 8.57 µg Cs/mL (AP-107 feed condition) was determined to be 669 mL AP-107/g CST. With a CST bed density of 1.00 g/mL, this K d corresponded to a predicted 50% Cs breakthrough of 669 bed volumes (BVs). The Cs load capacity at the equilibrium feed condition was determined to be 7.5 mg Cs/g dry CST. The column testing was prototypic to the intended LAWPS operations in a lead-lag column format, although on a small-scale basis with 10-mL CST beds. The feed was processed downflow through the lead column and then through the lag column at ~2.2 BV/h. Loading continued until the lag column reached the WTP waste acceptance criteria (WAC) for receiving supernatant waste for vitrification (a function of the Na and 137 Cs concentrations). For AP-107, the WAC is 0.114% of the influent 137 Cs concentration; this required a Cs decontamination factor of 876. The Cs effluent from the lag column reached the WAC after processing ~410 BVs. To keep the subsequent product effluent below the WAC, a replacement lag column was prepared, the lead column was removed from service (after processing a total of 471 BVs), the lag column was put into the lead column position, and the replacement lag column was installed. Feed processing continued and after another ~290 BVs the Cs effluent from the lag column again exceeded the WAC. In both cases, the lead columns only reached 25% Cs breakthrough before removal. Although 50% Cs breakthrough was not reached, this value was estimated and averaged based on extrapolation of the loading curves (640 BVs) and agreed within 4% of the predicted 50% Cs breakthrough from batch contact test results (669 BVs). Table ES.1 summarizes the observed column performance and relevant Cs loading characteristics.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Development of Digital Twin Predictive Model for PWR Components: Updates on Multi Times Series Temperature Prediction Using Recurrent Neural Network, DMW Fatigue Tests, System Level Thermal-Mechanical-Stress Analysis

The long-term operation (LTO) of nuclear power plant (NPP) beyond their original design life of 40 years, can lead to more material damage associated with cyclic fatigue under thermal-mechanical loading cycles and associated long-term exposure of reactor material to the deleterious reactor-coolant environments. However, under this LTO condition the reactor components can still safely operate but may require more frequent Nondestructive Evaluation (NDE) of reactor components. Frequent NDE requirement may lead to frequent shutdown of the NPP. This in turn can lead to power outage and additional NDE-inspection-cost related economic loss. The economic loss can be minimized by reducing uncertainty in life estimation of safety-critical pressure boundary components and by implementing more digital approach such as by using upcoming digital-twin (DT) technology for predicting the structural states (e.g., time and location dependent inside/outside thickness temperature, stress, strain, plastic deformation, etc.) and associated fatigue life of a component in real time. Towards this goal Argonne National Laboratory (ANL) with the sponsorship of DOE Light Water Reactor Sustainability (LWRS) program is working on the development of a DT framework that can be used for real time environmental fatigue prediction of reactor components. The DT framework is based on limited experiment-data, Artificial-intelligence (AI) – Machine-Learning (ML) - Deep-Learning (DL) based techniques and Multiphysics-computational-mechanics such as finite element (FE) based modeling tools. Towards this overall goal, following are some of the major contributions made during the FY21: 1) Multiple 82/182 dissimilar metal weld (DMW) specimens (both solid-weld and joint-weld representing the actual reactor multi-metal nozzles) were fatigue tested. The resulting fatigue lives were compared to the NUREG-6909 based best-fit and design fatigue curves. Additionally, the results of 52/152 DMW fatigue specimens (which were recently tested at Republic of Korea under the sponsorship of International Nuclear Energy Research Initiative - INERI program) were compared to the NUREG-6909 based best-fit and design fatigue curves. From the comparison of 82/182 and 52/152 DMW test data with NUREG-6909 best-fit curve, most of the reported test data fall way away from the NUREG-6909 suggested best-fit or mean curve. The NUREG-6909 suggested best-fit curve is the best-fit curve of austenitic stainless steel and due to lack of enough data on Nickel-based welds, this is currently being used for predicting the life of Nickel-alloy-based welded components. However, the above observation may require higher scaling factor (e.g., ASME suggested factor of 20 on cycles rather than the current NUREG-6909 suggested factor of 12 on cycles) for scaling the austenitic-stainless-steel best-fit-curve for estimating the design or safe-life of a welded component. Accordingly, for example, if a DMW component experience a strain amplitude of 0.6% the PWR-water life of the component would be 52 cycles instead of 85 cycles. However, more DMW tests are required to further ascertain the above-mentioned observations. 2) A system level CAD and finite element model were developed which consists of reactor pressure vessel (RPV), part of steam generator (SG), part of pressurizer (PRZ), hot leg (HL), and surge line (SL). This is with detailed nozzle geometry and thermal-mechanical material properties of different metals to simulate realistic thermal-mechanical stress under connected system global thermal-mechanical boundary conditions. 3) Different system level heat transfer analyses were performed with estimation of relevant heat transfer coefficients. The resulting data were used in subsequent system level thermal-mechanical stress analysis and for generating spatial-temporal training and validation data for a system level digital-twin based temperature predictor. Transient heat transfer analyses were performed considering thermal boundary condition under design-basis (DB) loading and EDF (Électricité de France) data-based grid-load-following (EDF-GLF) loading cycles. 4) System level thermal-mechanical stress analysis was performed for identifying damage-prone hotspots and for future extension of the model for cyclic state prediction. From the system-level model simulation under DB loading cycle it is found that HL and the SL nozzle that connect to the HL can experience significant stress and strain and could be one of the weakest links in the overall reactor coolant system (RCS). 5) An AI/ML based DT model was developed for multi-time-series temperature prediction at any inside/outside thickness locations of PWR pressure boundary components. This is by using Recurrent-neural-network (RNN) and keras machine learning libraries. The RNN model was validated against two laboratory test-based data sets with one obtained through ANL’s in-air fatigue test system and other through PWR-water test loop. The experimentally validated DT model further validated against FE model results to predict thermal scarification related spatialtemporal temperatures at random locations of a component. The well validated DT model was then used for demonstrating spatial-temporal temperature prediction under 100+ years of reactor operation subjected to combined DB, EDF-GLF and randomized grid-load-following (RANDOMGLF) loading Cycles. The expert-elicitation DT model framework was developed assuming field/input/process measurements can be available from a few existing plant sensors and can readily be used by the NPP operators. The above temperature prediction model will feed to the next-step stress analysis model based on which the life of a component can be predicted in realtime, which is one of our future works.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Initial Temperature Testing of Advanced Manufactured Melt Wire Package

As a part of the In-Pile Instrumentation Program, The Idaho National Laboratory (INL) has recently established in-house capabilities to fabricate and test new advanced manufactured sensors for measuring the peak irradiation temperature inside a nuclear test reactor. Although nuclear test reactors can use standard methods of real-time temperature monitoring, such as thermocouples, the complexity of feedthroughs and attachment complications to collect real-time measurements greatly increases the cost of the experiment. Passive monitoring techniques may be utilized that exploit the melting point of well characterized material (standard melt wires), however, the limited space available for instrumentation during experiments is also a challenge. To accommodate the challenge, INL has expanded its temperature detection instrumentation capabilities paired with the advancement of in-house advanced manufacturing options to include printed melt wires for peak irradiation temperature measurement. The advanced manufactured melt wire package can determine peak temperatures in experiments that can fit the challenging space available during irradiation. Recent results and knowledge from this ongoing work have made it possible to develop unique temperature sensors that can accomplish user specific temperature ranges inside the harsh environments experienced during radiation testing. This report summarizes the initial temperature testing using fabricated melt wires with two different melting temperatures, silver (melting temperature of ~960 °C) and solder (melting temperature of ~160 °C), that were initially tested for their relative melting points using non-standard method of furnace and hot plate testing under normal air conditions. Future work will include more controlled way of testing printed melt wires under inert gas with multiple temperature measurements followed by comparison of standard melt wire package performance for baseline characterization.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

USHPRR MP-1 Irradiation Test: Assessment of Edge Pitting and Bond Line Corrosion in Vendor Produced Fuel Plates

This report summarizes an effort to identify the source of anomalous localized edge pitting and bond line corrosive attack of experimental mini fuel plates manufactured at the commercial fuel vendor BWXT and tested in the Advanced Test Reactor (ATR) at Idaho National Laboratory (INL) as part of the Miniplate 1 (MP-1) irradiation test. The MP-1 test was conducted by the US High Performance Research Reactor Project (USHPRR) and overseen by the Fuel Qualification Pillar (FQ). The test involved evaluation of a mix of 62 “vendor” fuel plates fabricated at BWXT and 12 “laboratory” fuel plates fabricated at Idaho National Laboratory using commercial-scale and labscale fabrication processes respectively. The MP-1 test was the first in a series of tests to generate data to support qualification of a new plate-type low-enriched uranium (LEU) U-10Mo monolithic fuel system. The major objective of the MP-1 experiment was to test, for the first time, miniplates fabricated by a commercial fuel vendor over the range of irradiation conditions relevant to conversion of NRC regulated High Performance Research Reactors (HPRRs) from high-enriched uranium to LEU. The focus of the efforts described in this report are the vendor fuel plates to inform changes in the fabrication process prior to fabrication of the next miniplate experiment MP2.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

NorthStar Facility Target Fab and Flow Testing - FY 21

The facility target fabrication and flow testing activity will consist of flow tests using the blower system at LANL to test the disk holder and target, both redesigned by the NorthStar prime contractor. The housing and transition system delivering helium cooling to the disc holder and target will be fabricated and tested at LANL facilities. The tests will include pressure drop versus flow measurements through the target and housing, optical flow diagnostics and fiber optic imaging of the disc stack. The pressure drop measurements will be compared to CFD simulations to verify the latter, the optical flow diagnostics will be used to determine whether modifications made to the housing and target holder allow sufficient flow through the bottom of the housing to adequately cool it and the fiber optics will be used to image the discs during operation as a proof of concept of the diagnostic, to be used at NorthStar facilities during preproduction testing. The work is a Partial Fulfillment of the Deliverable Requirement for NorthStar Facility Target Fab and Flow Testing and Production Target Testing Support by LANL

42 ENGINEERING↗

Benchmark Specification for FFTF LOFWOS Test #13

The Fast Flux Test Facility (FFTF) at the Hanford site in Washington was designed by the Westinghouse Electric Corporation for the U.S. Department of Energy. FFTF was a 400 MW thermal, oxide-fueled, liquid sodium cooled test reactor, built to assist development and testing of advanced fuels and materials for fast breeder reactors. After reaching criticality in 1980, FFTF operated until 1992, providing the U.S. Department of Energy (DOE) with the means to test fuels, materials, and other components in a fast neutron flux environment. In July 1986, a series of unprotected transients (with the plant protection system intentionally disabled) were performed in FFTF as part of the passive safety demonstration program. Among these were thirteen loss of flow without scram (LOFWOS) tests. The goals of this program included confirming the liquid metal reactor safety margins, providing data for computer code validation, and demonstrating the inherent and passive safety benefits of specific design features. The test defined in this benchmark is LOFWOS Test #13, which was initiated at 50% power and 100% flow with the pump pony motors turned off. This benchmark specification is intended to support collaborative efforts within international partnerships on the validation of simulation tools and models in the area of Sodium-cooled Fast Reactor (SFR) safety. Validated tools and models are needed to evaluate SFR inherent safety characteristics and assess the impact of passive design features in response to accident initiators. Comparisons with experimental data and the results of safety analyses from other groups create unique opportunities to improve predictive capabilities of computational codes and methods for SFR modeling and simulation. The conditions of the LOFWOS test along with the feedback from FFTF’s limited free bow core restraint system and the novel passive reactivity control Gas-Expansion Modules (GEMs) pose a very challenging and uniquely valuable benchmark exercise.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Pilot Testing of a Highly Efficient Pre-combustion Sorbent-based Carbon Capture System

TDA developed and demonstrated a highly efficient pre-combustion carbon capture system. The overall objective of this work was to develop a new sorbent-based pre-combustion carbon capture technology for Integrated Gasification Combined Cycle (IGCC) power plants. In this project our goal was to demonstrate the techno-economic viability of the new technology by 1) demonstrating it in large-scale slipstream tests, and 2) carrying out a high fidelity engineering and cost analysis. TDA’s process used an advanced physical adsorbent that selectively removes CO 2 from coal-derived synthesis gas above the dew point of the gas at temperatures as high as 300°C. The sorbent consists of a mesoporous carbon whose surface was grafted with functional groups that remove CO 2 via a well-known acid-base interaction. As documented in bench-scale experiments and field tests with actual coal gas, the sorbent achieved a very high capacity for CO 2 at temperatures as high as 300°C. The sorbent bound CO 2 more strongly than common physical adsorbents, providing the chemical potential needed for the high temperature operation. However, because CO 2 does not form a true covalent bond with the surface sites (as is the case with chemical absorbents), the sorbent regeneration could be carried out with only a very small energy input. The heat input to regenerate our sorbent was only 4.9 kcal per mol of CO 2 , which is much lower than that for chemical absorbents (e.g., 29.9 kcal/mol CO 2 for sodium carbonate) and was similar to the requirements of physical solvents (e.g., 4 kcal/mol CO 2 for Selexol TM ). Because the sorbent operates above the dew point of the synthesis gas (unlike the Selexol TM process), a higher power cycle efficiency can be achieved. With previous DOE/NETL funding (Contract No. DE-FE-0000469), we demonstrated the techno-economic viability of the technology in bench-scale tests and slipstream demonstrations at the National Carbon Capture Center (NCCC), Wilsonville, Alabama and Wabash River IGCC plant in Terra Haute, Indiana. We demonstrated a stable working CO 2 capacity for over 11,650 cycles with simulated synthesis gas. We also evaluated its performance with actual synthesis gas in two test campaigns at the Wabash River IGCC Plant, Terre Haute, IN and the National Carbon Capture Center (NCCC), Wilsonville, AL. The slipstream tests clearly showed that the actual coal gas constituents and potential contaminants (e.g. trace metals, halides, tars) had no effect on the sorbent’s ability to remove CO 2 (the same sorbent beds were used in both field tests with no sign of deactivation for 2,000 cycles with over 26,750 SCF of gas treated). As expected, due to the high temperature CO 2 removal capability and low energy needed to regenerate the sorbent, the power cycle efficiency with our process was greater than 34% on a higher heating value (HHV) basis; in comparison, the same IGCC plant equipped with the Selexol TM solvent for carbon capture can only achieve 31.4% HHV efficiency. The capital cost for an IGCC system with TDA’s process is estimated as $2,417/kW e , which is 12% lower than that of the IGCC/ Selexol TM process. The levelized cost for electricity including the transport, storage and monitoring (TS&M) cost for CO 2 was calculated as $\$ $92.9/MWh (lowest reported to our knowledge), which is much better than the $105.2/MWh estimated for the IGCC/ Selexol TM process. In this project (DE-FE0013105), TDA Research, in collaboration with our partners Gas Technology Institute (GTI), Illinois Clean Coal Institute (ICCI), University of California, Irvine (UCI), University of Alberta (UOA), Siemens, NCCC and Sinopec advanced the technical maturity of the technology; scaling it up by a factor of 100. We optimized the reactor design using computational fluid dynamics (CFD); using adsorption modeling we improved the pressure swing adsorption (PSA) cycle sequence. We carried out two field test campaigns with a fully-equipped 0.1 MW e prototype unit (for a total of 844 hours) using actual synthesis gas to prove the viability of the new technology. A successful 30 day (707 hrs) evaluation was completed at NCCC under air blown gasification conditions. We demonstrated 97.3% carbon capture at 1,500 SLPM, 93% carbon capture at 1,800 SLPM, and 90% carbon capture at 2,100 SLPM in the NCCC tests. We also demonstrated the system for 137 hours at a Sinopec petrochemical plant under oxygen blown gasification, demonstrating 86% carbon capture at 2,660 SLPM. In collaboration with University of California, Irvine (UCI), we completed a techno-economic analysis (TEA) for TDA’s warm gas cleanup technology integrated to IGCC power plant. The net plant efficiencies (on a coal HHV basis) for the warm gas cleanup cases were estimated to be 34.0% for E-GasTM gasifier, 34.4% for GE gasifier, 33.4 for the Shell gasifier and 34.2 for the TRIG TM gasifier (Cases 2, 4, 6 and 8 in this study) with a catalytic combustor for CO 2 purification, which are significantly higher than those for the Cold Gas Case, or an increase of as much as 12% in the heat rate for Case 2, 6% for Case 4, 9% for Case 6, and 9% for Case 8. The 1st year cost of electricity with the transport, storage and monitoring (TS&M) costs for the CO 2 included was $\$ $129.2/MWh for the E-GasTM gasifier Warm Gas Cleanup Case, $\$ $131.9/MWh for the GE gasifier Warm Gas Cleanup Case, $\$ $146.8/MWh for the Shell Gasifier Warm Gas Cleanup Case, and $\$ $129.9/MWh for the TRIG TM gasifier Warm Gas Cleanup Case. For comparison, the costs for the baseline Cold Gas CO 2 removal with Selexol for the different gasifiers were: $\$ $146.6/MWh for the E-Gas TM gasifier, $\$ $142.2/MWh for the GE gasifier, $\$ $159.0/MWh for the Shell gasifier and $\$ $144.3/MWh for the TRIG TM gasifier. In summary, the costs for our system were 7 to 12% lower than the corresponding Cold Gas Cleanup cases. The results of this techno-economic analysis suggested that TDA’s high temperature PSA-based Warm Gas Clean-up Technology can make a substantial improvement in the IGCC plant thermal performance for achieving near zero CO 2 emissions for E-Gas TM , GE, Shell and TRIG TM gasifier based IGCC power plants. The capital expenses were estimated to be lower than that of Selexol’s™. Taken together, the higher net plant efficiency and lower capital and operating costs resulted in substantial reduction in the cost of carbon capture for the IGCC plant equipped with TDA’s high temperature PSA-based carbon capture system. Finally, in collaboration with Gas Technology Institute (GTI) we completed the environmental health and safety assessment for TDA’s warm gas carbon capture technology.

01 COAL, LIGNITE, AND PEAT↗