Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

Design of Experiments for Dynamic Test Runs in Solvent-Based CO 2 Capture Pilot Plants

Test runs in the pilot plants consume significant resources, and therefore, the learning from test runs should be maximized. Test runs conducted in the pilot plants are often steady state. It takes several hours for reaching steady-state in the pilot plants, and thus, the duration of the test runs needs to be long even for collecting few steady-state data points. On the other hand, a large number of measurements can be collected through dynamic test runs in a short span of time. This paper presents a systematic design of dynamic experiments (DoDEs) for identifiability of model parameters, which is achieved by persistently exciting the inputs signals. A pseudorandom binary sequence (PRBS) is designed as the input signal for DoDE due to its efficiency in obtaining sufficient spectral content. However, due to the long sequence size of the PRBS signal, a Schroeder-phase input signal, which is a multisine signal, is also designed. Tests for both types of signals are run in the Pilot Solvent Test Unit (PSTU) at the National Carbon Capture Center in Wilsonville, Alabama. The transient data are used to solve dynamic data reconciliation and parameter estimation problem. The estimated parameters are found to be not only superior to those estimated from using data collected from hundreds of steady-state test runs in a nonreactive (air–water) system, but the parameters could be estimated by using the dynamic data collected for about 24 h from the pilot plant for the MEA-H 2 O–CO 2 system.

CO2 capture↗

The development and application of the stirred‐reactor coupon analysis (SRCA) test method

A new technique, termed the stirred‐reactor coupon analysis (SRCA) method, has been developed to measure the rate of glass dissolution in forward‐rate conditions. Monolithic glass coupons are partially masked with an inert material before placement in a large volume of well‐mixed solution with known chemistry and temperature for a predetermined duration. After the test, the mask is removed, and the difference in step height between the protected area and the exposed corroded portions of the sample coupon is measured to determine the extent of glass dissolution. The step height is converted to a rate measurement using the test duration and glass density. Test parameters such as sample surface preparation and test duration were evaluated to determine their effects on the measured rates. Additionally, results from an interlaboratory study (ILS) consisting of 12 laboratories from 11 different institutions are presented, where each laboratory performed 12 independent tests. When removing experimental outlier data, the 95% reproducibility limits for the SRCA method has no statistical difference with previously published standardized test methods used to determine the forward rate of glass dissolution. Overall, this paper describes steps necessary to perform the test method and provides the statistical calculations to evaluate test accuracy.

chemical durability↗

FOSWEC v2: System identification and control testing at Hinsdale Wave Research Laboratory

This report summarizes the design and execution of a wave tank test of the floating oscillating surge wave energy converter (FOSWEC) in the O.H. Hinsdale Wave Research Laboratory Directional Wave Basin at Oregon State University. This device, which uses two "flaps" that pivot about a central platform when excited by waves, has a natural frequency within the range of the waves by which it is excited. The FOSWEC was originally considered to be a 1:33 scale device, however, for the current tests, no fixed relative scale is used (i.e., the WEC is considered to be scaled for the basin’s wave environment in which it operates). The primary goal of this test was to assess the degree to which previously developed modeling, experimentation, and control design methods could be applied to a broad range of wave energy converter designs. Testing was conducted to identify a dynamic model for the impedance and excitation behavior of the device. Using these models, a series of closed loop tests were conducted using a causal impedance matching controller. This report provides a brief description of the results, as well as a summary of the device and experimental design. The results show that the methods applied to this experimental device perform well and should be broadly applicable. The data collected during testing is compressed into FOSWEC.zip. Please refer to Appendix C (pages 61-63) of the test report for descriptions of each test ID corresponding to the compressed files.

16 TIDAL AND WAVE POWER↗

Functional and Operating Requirements for the Microreactor Agile Non-Nuclear Experimental Test Bed (MAGNET)

Microreactors, or small, transportable reactors with a capacity of < 20 MWTH, are sought to provide heat and power for myriad applications in remote areas, military installations, emergency operations, humanitarian missions and disaster relief zones as illustrated in Figure 1. These small, transportable reactor designs, while offering many advantages, are largely untested and unproven. System and component testing is needed to demonstrate to regulators that these designs are safe and to convince customers that the systems are robust, reliable, and efficient. The microreactor agile non-nuclear experimental test bed (MAGNET) is being constructed at Idaho National Laboratory to assist with the development, demonstration, and validation of microreactor components and systems. MAGNET will support technology maturation to reduce uncertainty and risk relative to the operation and deployment of this unique class of systems. Stakeholders for this test bed include microreactor developers, energy users, and regulators. Regulators will be engaged early in the design and testing to expedite regulatory approval and licensing. Within MAGNET, systems and components can be safely tested, providing valuable information on operating regimes, failure modes, and thresholds. Since there are various types of microreactors being proposed, which can be classified according to their core cooling method, heat-pipes, gas-cooled (pebble bed or prismatic), molten salt, light water, or light water, the goal is to provide a test bed that is broadly applicable to multiple microreactor concepts. Each reactor type poses a different set of design and operational challenges and performance claims stated by commercial vendors have not been independently verified through rigorous testing. The initial set of tests to be performed in MAGNET are targeted towards demonstrating the feasibility and performance of heat-pipe cooled reactors, since this concept is unique to very small nuclear reactors. However, the testbed will be constructed to accommodate other designs in addition to heat-pipe cooled reactors.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

A Perspective on the Successes of the NNSS Underground Test Area (UGTA) Activity - 20221

Between 1951 and 1992, 828 underground nuclear tests were performed at the Nevada National Security Site (NNSS). Underground testing was done in five major testing areas, which included (1) Frenchman Flat, (2) Rainier Mesa/Shoshone Mountain, (3) Yucca Flat/Climax Mine (4) Central Pahute Mesa, and (5) Western Pahute Mesa. About one third of the underground tests were detonated near, at or below the water table, and thus radioactive contamination was introduced to the groundwater system. The U.S. Department of Energy's Underground Test Area (UGTA) Activity was established in the late 1990's to address the fate and movement of residual radioactivity in groundwater, and characterize the risk that it may pose to NNSS workers and the offsite public. It has accomplished this goal through a process of iterative groundwater sampling and numerical groundwater flow and transport modeling, and long-term monitoring. The UGTA Activity draws on the expertise of scientists in the fields of geology, hydrology, radiochemistry, and risk assessment from the U.S. DOE staff, the lead contractor (currently Navarro) and many other organizations, in cooperation with the governing regulatory body, the State of Nevada's Division of Environmental Protection (NDEP). Los Alamos National Laboratory (LANL) is one of the participating research organizations involved with the UGTA Activity. Under the direction of DOE and the lead contractor, LANL's role in UGTA has evolved over time from an initial focus on geologic characterization, to conducting field and laboratory experiments, and finally to its current role of providing modeling and geochemistry expertise to characterize the rates and directions of groundwater and radionuclide movement. In its current role, LANL has either developed or provided the numerical tools for developing flow and transport models in each of the four major testing areas. In addition, LANL has provided an independent assessment of future groundwater flow and transport behavior through the analysis of naturally-occurring geochemical and isotopic tracers in groundwater. The five major testing areas are now in different stages of investigation or closure: (1) Frenchman Flat is in its fifth year of post closure modeling; (2) The Rainier Mesa/Shoshone Mountain Closure Report has been submitted to NDEP and is awaiting approval; (3) The Yucca Flat/Climax Mine Closure Report is under development; and (4) Central and (5) Western Pahute Mesa is still undergoing investigation and flow and transport model development. The success of the UGTA Activity in reaching or approaching closure in three of the five major testing areas is primarily due to the DoE's focus on regulatory closure requirements, but also is in part attributable to a rigorous internal review process and the involvement of NDEP and Nye County water professionals as participants and observers in the reviews. County and state involvement in the internal review process has promoted trust that the U.S. DOE is deeply committed to ensuring the present and future safely of NNSS workers and the surrounding communities. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Image Distinguishability Analysis Testing Through Principal Components and Its Application to Hot Spot Scale Invariance

Hot spots are spatial regions of intense energy localization that govern initiation of secondary high explosives. Studies that characterize or compare simulated hot spots are frequently either qualitatively descriptive or resort to quantitative distribution functions that neglect stochastic variations and spatial correlations—effects that are also neglected in common comparison tests like the Kolmogorov–Smirnov test. To this end, we develop an image distinguishability analysis (IDA) test based on principal component (PC) analysis that makes pixel-by-pixel comparisons between small, for example, O(<10), image data sets. The IDA test makes comparisons through a generalized distance metric in the PC space and a test statistic that is derived to calculate mathematical equation-values. Here, we derive a statistical distribution and criticality criterion to determine whether images are distinguishable from established baselines. We apply the IDA test on images generated from molecular dynamics simulations of hot spots from pore collapse in TATB to assess scale invariance in the complex patterns of hot spots that form in a representative high explosive crystal. The IDA test shows that TATB hot spot spatial temperature fields and their derived temperature histograms exhibit scale-invariant features over specific intervals of shock orientation, strength, and initial pore diameter. However, the IDA test also shows that qualitatively different conclusions regarding invariance can be reached depending on whether the hot spot is treated as a spatially correlated field as opposed to a distribution function that lacks spatial information.

organic↗

Using in-situ strain measurements to evaluate the accuracy of stress estimation procedures from fracture injection/shut-in tests

Fracture injection/shut-in tests are commonly used to measure the state of stress. Injection creates a hydraulic fracture (or in some cases, opens a preexisting fracture), and then the pressure after shut-in is monitored to identify fracture closure. Different interpretation procedures have been proposed for estimating closure, and the procedures sometimes yield significantly different results. In this study, direct, in-situ strain measurements are used to observe fracture reopening and closure. The tests were performed as part of the EGS Collab project, a mesoscale project performed at 1.25 and 1.5 km depth at the Sanford Underground Research Facility. The tests were instrumented with the SIMFIP tool, a double-packer probe with a high-resolution three-dimensional borehole displacement sensor. The measurements provide a direct observation of the fracture closure signature, enabling a high-fidelity estimate of the fracture closure stress (ie, the normal stress on the fracture). In two of the four tests, injection created an opening mode fracture, and so the closure stress can be interpreted as the minimum principal stress. In the other two tests, injection probably opened preexisting natural fractures, and so the closure stress can be interpreted as the normal stress on the fractures. The strain measurements are compared against different proposed methods for estimating closure stress from pressure transients. The shut-in transients are analyzed with two techniques that are widely used in the field of petroleum engineering – the ‘tangent’ method and the ‘compliance’ method. In three of the four tests, the tangent method significantly underestimates the closure stress. The compliance method is reasonably accurate in all four tests. Closure stress is also interpreted using two other commonly-used methods – ‘first deviation from linearity’ and the method of Hayashi and Haimson. In comparison with the SIMFIP data, these methods tend to overestimate the closure stress, evidently because they identify closure from early-time transient effects, such as near-wellbore tortuosity. In two of the tests, microseismic imaging provides an independent estimate of the size of the fracture created by injection. When combined with a simple mass balance calculation, the SIMFIP stress measurements yield predictions of fracture size that are reasonably consistent with the estimates from microseismic. In conclusion, the calculations imply an apparent fracture toughness 2-3x higher than typical laboratory-derived values.

58 GEOSCIENCES↗

Dispersal of high-burnup fuel fragment surrogate particles during and after loss-of-coolant accident tests

The issue of fuel fragmentation, relocation, and dispersal is critical in the licensing and use of high-burnup (>62 GWd/MTU) nuclear fuel in light water reactors (LWRs). In this work, two test series are reported that examine the fragment dispersal during a burst event and an additional dispersal following the burst due to vibrations in the rod, such as those induced by accident recovery systems. To examine dispersal during the balloon and burst portion of a Loss-of-Coolant Accident event, HfO 2 fragments and yttria-stabilized zirconia pellets were filled into an as-fabricated cladding tube, which was then pressurized and subjected to loss-of-coolant accident testing in steam. Results from this test were found to be highly non-prototypic, and dispersal was both significantly more violent and significantly greater in magnitude than identified for actual fuel tests. These findings were attributed to the conservative (more dispersive) nature of the particles chosen for dispersal and to the details of the test conditions used that led to particularly wide bursts. Further, the second set of tests examined dispersal following the burst when vibrations were induced in the rod, primarily via recovery activities such as Emergency Core Cooling System actuation leading to rapid water addition. Post-burst dispersal testing was performed by inducing sinusoidal oscillations with 2–25 nm peak-to-peak amplitude and 2–5 Hz frequencies in pre-burst rods that had been refilled with HfO 2 fragments or high-burnup fragment surrogate mixture of HfO 2 fragments and yttria-stabilized zirconia sands. Testing revealed that rods with large burst openings (7 mm wide in this work) led to unmitigated dispersal from above the burst zone but that smaller bursts (5 mm wide), although still much larger than the mean fragment size of 3 mm, led to effectively no dispersal because of interparticle locking. Additionally, mixture and moisture were found to impact the amount of dispersal: mixtures increased dispersal, and moisture drastically reduced it. The implications of these findings on likely dispersal from actual fuel are discussed.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Foreword Special issue on the Kilopower Project, Kilowatt Reactor Using Stirling TechnologY (KRUSTY) Test

This special issue of Nuclear Technology contains full-length, peer-reviewed papers describing the design work leading up to and the results of the Kilowatt Reactor Using Stirling TechnologY (KRUSTY) test. KRUSTY was the centerpiece of the National Aeronautics and Space Administration (NASA) Kilopower Project to design, build, and test a space nuclear reactor. This test was the first such test since the end of the Space Nuclear Auxiliary Power (SNAP) project at the end of the 1960s. In this issue, the introduction paper presents the goals of the Kilopower Project and the potential missions this reactor concept could serve in NASA. Kilopower was intended to serve both human exploration needs on planetary surfaces as well as science needs for deep-space exploration. The design work for the experiment by Poston and the power conversion development by Gibson present the pre-work required to perform the eventual KRUSTY test. A paper on regulatory analysis follows, to show the path used to gain approval of the proposed experiment. Then, the early zero-power critical experiments are presented by Sanchez and Grove. These experiments were essential data used to enhance model predictions prior to the high-temperature test. Next, Poston presents the three experiments (warm criticals) that increase the temperature in an incremental fashion prior to the final experiment. These experiments were used to achieve final regulatory approval of the final high-temperature experiment. The last paper by Poston presents the results of the steady-state and transient testing of the reactor at full power and at the design temperature. These results show that the reactor design and as-built experiment met all of the requirements that NASA had developed for the system. Any experiment of this magnitude was accomplished only because of the hard work and dedication of a large number of people at multiple institutions, including the NASA Glenn Research Center, NASA Marshall Space Flight Center, Y-12 National Security Site, Los Alamos National Laboratory, and the Nevada National Security Site prime contractor (formerly National Security Technologies and now the Mission Support and Test Services). The project was jointly funded by the Space Technology Mission Directorate at NASA and the Criticality Safety Program at the National Nuclear Security Administration (NNSA). A special thanks to Jerry McKamy and Angela Chambers at the NNSA and Lee Mason and Don Palac at NASA for their support and guidance. For the authors and multitude of staff that performed this work, the passion for space nuclear reactors was the key to making this experiment a reality.

99 GENERAL AND MISCELLANEOUS↗

Code Benchmark of the HTTF Pressurized Conduction Cooldown Test Using SAM

The High Temperature Test Facility (HTTF) at Oregon State University is an integral system test facility to simulate postulated reactor transients of prismatic high-temperature gas-cooled reactors(HTGRs). A series of test campaigns was launched, providing abundant test data that could be used to benchmark reactor system analysis codes like the System Analysis Module (SAM). In this study, a SAM model of the facility is developed based on the two-dimensional (2D) ring model approach. All components including the ceramic matrix, graphite heaters, helium coolant channels, core barrel, upcomer, pressure vessel, and reactor cavity cooling system are modeled as concentric cylindrical rings. The model is used to simulate one of the benchmark problems-Pressurized Conduction Cooldown (PCC)-within the scope of the Organisation for Economic Co-operation and Development Nuclear Energy Agency International HTTF Benchmark. The simulations consist of two parts. In the first part, operating and boundary conditions as well as thermophysical properties of materials are specified for the benchmark problem. In this work, results from the first part will be used in code-to-code comparison. In the second part, the SAM model is used to simulate Test PG-27, which is the first PCC test carried out in the HTTF, with only two of the ten heater banks activated. The results in the second part are used for code-to-data comparison. Because the helium coolant flow rate is not measured in this facility, it is estimated using the input power and inlet/outlet coolant temperatures. Additionally, radial heat flow in the ceramic blocks is complicated by hundreds of cylindrical coolant channels and heater rods embedded in them. As such, it is necessary to deduce an effective thermal conductivity for the ceramic to analyze the core thermal behavior. SAM predictions of the helium coolant and ceramic temperatures are compared with test data measured in three equivalent sectors. Overall, the SAM results agree reasonably well with test data within the variation of data among the three sectors, which demonstrates SAM's capability in capturing transient effects in HTGR using the simplified 2D ring model.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Update to the Microcontroller Benchmark for Radiation Testing

LANL developed a benchmark of software code for radiation testing of microprocessors several years ago, and it was published under an open-source license on GitHub. Publishing the software is necessary for other researchers to adopt and implement this benchmark for radiation testing of other microprocessors to standardize test practices so that test data can be compared across different microprocessors. The original codes have been used several times by other organizations to test a wide range of microcontrollers and microprocessors. After several years of research, LANL is ready to update the benchmark. Changes include: 1. Addition of new codes that allow common software codes to be tested, 2. Addition of new codes that instrument more microprocessor circuitry, 3. Addition of input patterns that allow for a more compressive understanding of how the memory layout affects the sensitivity to radiation-induced faults and better use of automated test pattern generation standards, and 4. Modification of current codes for faster and more resilient detection, reporting and correction of radiation-induced faults. These codes have been tested by LANL researchers over the last few years, which has been published in the open literature. As the code base for the new benchmarks are stable, it is time to release the update to the GitHub repository, where the original codes were released.

Quinn, Heather↗

In-situ thermomechanical measurements during burst testing of Zr claddings using digital image correlation and infrared thermography techniques

Burst testing has long been a relied-on method for assessing fuel cladding materials in light-water reactoraccident scenarios. However, burst testing historically provided minimal in-situ observations beyond a few thermocouple readings, pressure from transducers, and post-test deformation measurements. Acquisition of full cladding thermomechanical data throughout a burst test would be invaluable to fuel system qualification, material model development and fuel performance code validation, such as the BISON fuel performance code. Recently, methodologies for simultaneously applying 2-dimensional digital image correlation and infrared thermography techniques to quantify the relationship between temperature, internal cladding pressure, and deformation during burst testing were developed. This work details results from the application of these techniques to burst testing of Zircaloy-4 cladding segments subjected to loss-of-coolant accident transients in an air environment. Two types of tests were performed with: (a) cladding segments connected to a fixed pressure reservoir as well as (b) closed systems where internal pressure increased during transients. In-situ thermomechanical measurements including strain and thermal gradient data are presented, demonstrating the effectiveness of applying combined surface measurement techniques to burst testing

Bell, Sam↗

Validation and Recalibration of the Solubility Models in Support of the Heater Test in Salt Formations

The US Department of Energy Office of Nuclear Energy is conducting a brine availability heater test to characterize the thermal, mechanical, hydrological and chemical response of salt at elevated temperatures. In the heater test, brines will be collected and analyzed for chemical compositions. In order to support the geochemical modeling of chemical evolutions of the brines during the heater test, we are recalibrating and validating the solubility models for the mineral constituents in salt formations up to 100°C, based on the solubility data in multiple component systems as well as simple systems from literature. In this work, we systematically compare the model-predicted values based on the various solubility models related to the constituents of salt formations, with the experimental data. As halite is the dominant constituent in salt formations, we first test the halite solubility model in the Na-Mg-Cl dominated brines. We find the existing halite solubility model systematically over-predict the solubility of halite. We recalibrate the halite model, which can reproduce halite solubilities in Na-Mg-Cl dominated brines well. As gypsum/anhydrite in salt formations controls the sulfate concentrations in associated brines, we test the gypsum solubility model in NaCl solutions up to 5.87 mol•kg –1 from 25 ° C to 50 ° C. The testing shows that the current gypsum solubility model reproduces the experimental data well when NaCl concentrations are less than 1 mol•kg –1 . However, at NaCl concentrations higher than 1, the model systematically overpredicts the solubility of gypsum. In the Na + —Cl – —SO 4 2– —CO 3 2– system, the validation tests up to 100 ° C demonstrate that the model excellently reproduces the experimental data for the solution compositions equilibrated with one single phase such as halite (NaCl) or thenardite (Na 2 SO 4 ), with deviations equal to, or less than, 1.5 %. The model is much less ideal in reproducing the compositions in equilibrium with the assemblages of halite + thenardite, and of halite + thermonatrite (Na 2 CO 3 •H 2 O), with deviations up to 31 %. The high deviations from the experimental data for the multiple assemblages in this system at elevated temperatures may be attributed to the facts that the database has the Pitzer interaction parameters for Cl – —CO 3 2– and SO 4 2– —CO 3 2– only at 25 ° C. Finally, in the Na + —Ca 2+ —SO 4 2– —HCO 3 – system, the validation tests also demonstrate that the model reproduces the equilibrium compositions for one single phase such as gypsum better than the assemblages of more than one phase.

36 MATERIALS SCIENCE↗

The Effect of Prostate-Specific Antigen (PSA) Test on Radiation Risk Estimate for Prostate Cancer Incidence among Atomic-Bomb Survivors

Following our previous report on the radiation doseresponse for prostate cancer incidence rates in the Life Span Study (LSS) cohort of atomic bomb survivors, we reevaluated the radiation-related risk adjusting for differences in baseline cancer incidence rates among three subsets of the LSS cohort defined by the timing of their first participation in biennial health examinations offered to the Adult Health Study (AHS) sub-cohort members and prostate-specificantigen (PSA) testing status for AHS participants: 1. nonAHS participants, 2. AHS participants before receiving PSA test, and 3. AHS participants after receiving PSA test. We found a 2.9-fold increase in the baseline incidence rates among AHS participants after receiving PSA test. After adjusting for the PSA-testing-status effects on the baseline rates the estimated excess relative risk (ERR) per Gy was 0.54 (95% CI: 0.15, 1.05), which was almost identical to the previously reported unadjusted ERR estimate (0.57, 95% CI: 0.21, 1.00). The current results confirmed that, while the PSA testing among AHS participants increased the baseline incidence rates, it did not impact the radiation risk estimate, strengthening the previously reported dose-response relationship for prostate cancer incidence in the LSS. As the use of PSA tests continue in screening and medical settings, analyses of possible effects of PSA testing should be an important aspect of future epidemiological studies of the association between radiation exposure and prostate cancer.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Influence of Glycolate Anion on Aqueous Corrosion in DWPF and Downstream Facilities – SCC Testing

Glycolic acid is being evaluated as an alternate reductant in the preparation of High Level Waste for the Defense Waste Processing Facility (DWPF) at the Savannah River Site (SRS). During processing, the glycolic acid may not be completely consumed with small quantities of the glycolate anion being carried forward to waste facilities. The SRS liquid waste contractor requested an assessment of the influence of the glycolate anion on the corrosion of the materials of construction (MoC) throughout the waste processing system since this concern had not been previously evaluated. The influence of glycolic acid on the occurrence of stress corrosion cracking (SCC) had not been evaluated specifically in the previous testing. The present testing used electrochemical and coupon immersion testing to assess this influence. Additionally, the primary guidance on corrosion for operating DWPF with a formate-based flowsheet is based on testing that utilized test solutions with a small number of constituents. Recent testing used more complex solutions based on flowsheet development for DWPF. Additional electrochemical tests were also conducted to assess the influence of this difference on test results.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Of Clouds and Craters: The History of U.S. Nuclear Weapons Testing

“Now!” With that word, the Atomic Age – and the era of nuclear weapons testing – dawned. The advent of World War II’s first irresistible weapon, which had been secretly tested in the New Mexico desert in July 1945, would help hasten the inevitable: complete victory for the Allies. Codenamed Trinity, the test was the first of over a thousand conducted by the United States between 1945 and 1992. Nuclear weapons would change future clashes as well. The looming Cold War, with roots stretching all the way back to 1917, was history’s first conflict between two, major nations armed with nuclear weapons. It is clear the existence of those weapons played an important role in maintaining a tenuous peace between the United States and the Soviet Union; it is also clear nuclear weapons testing played a prominent role in fueling both the arms race and the success of deterrence. Yet, the history of nuclear weapons testing is rarely remembered, even though nuclear tests have been performed in the very recent past. Of the estimated 2,000-plus nuclear tests ever performed, the U.S. is responsible for approximately half. This is the story of U.S. full-scale nuclear weapons testing.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Analysis of Respirator Cartridge Performance Testing on Hanford Tank A-101

Washington River Protection Solutions (WRPS) conducted tests on two types of chemical cartridges for use in air purifying respirators (APR) to determine the period of time that the cartridges would provide adequate performance1 to protect workers when exposed to a mixture of Chemicals of Potential Concern (COPCs) from vapors emanating from the headspace of tank A-101 on the Hanford Site. The Occupational Safety and Health Administration (OSHA) identifies cartridge testing as a valid approach for establishing a cartridge change schedules.[3] Testing is commonly applied in situations where mixtures of COPCs exist, and where other approaches, such as manufacturer recommendations and modeling, are less reliable. The tests were designed and conducted to ensure measurement and/or control of the key variables OSHA identified as important to estimate cartridge service life, including temperature, humidity, COPC concentration, breathing rate, and cartridge adsorption capacity. Testing was conducted over a period from July 22-24, 2016, using headspace vapors from Hanford tank A-101 under static conditions2 fed to a respirator cartridge test stand developed by WRPS in collaboration with HiLine Engineering (Richland, Washington). Multipurpose respirator cartridges, SCOTT 7422-SD1 and 7422-SC1 (SCOTT Safety, Monroe, North Carolina) were assessed on separate days with A-101 headspace vapors. Sample media (sorbent tubes) were used to collect samples of the vapor stream entering and exiting the respirator cartridge, and were subsequently analyzed for COPC concentrations. Pacific Northwest National Laboratory was tasked with conducting an independent analysis of the analytical results and making recommendations based on the results for respiratory cartridge performance and service life. Key conclusions from the assessment of the 59 COPCs in this study are described below: • Based on d measured cartridge inlet vapor concentrations from tank A-101 headspace, both ammonia and N-Nitrosodimethylamine (NDMA) exceeded their Occupational Exposure Limits (OEL).3 These measurements were generally consistent with maximum A-101 headspace measurements previously obtained for these two compounds. • Ammonia had respirator cartridge outlet concentrations that exceeded 10% of the OEL for both cartridges tested, indicating breakthrough for each. For the SCOTT 7422-SD1 cartridge, ammonia appeared to breakthrough above 10% of its OEL after 2 hours. For the SCOTT 7422-SC1 cartridge, ammonia breakthrough appeared to occur after 8 hours. 1 “Adequate performance” refers to the breakthrough criteria used in this analysis—that is, sustained cartridge outlet concentrations above 10% of the OEL. For some COPCs, an alternate threshold has been applied when necessary due to higher detection limit (DL)/reporting limit (RL) values for specific compounds. Ultimately, Industrial Hygiene professionals will use these results along with specific hazard assessments to determine service life and cartridge use that provides the necessary performance. 2 These tests were conducted under static conditions absent waste-disturbing activities in the subject tank or tank farm. 3 Occupational Exposure Limits accepted for Hanford Tank Farm use are based on OELs established by a U.S. governmental agency or national professional organization (e.g., OSHA, National Institute for Occupational Safety and Health, American Conference of Governmental Industrial Hygienists), or if no U.S. OEL exists, standard toxicological practices are applied to develop OELs using non-U.S. exposure limits, other established OELs for chemical surrogates when available, or other standard procedures. The OEL for NDMA was established in 2005 based on the MAK (Maximale Arbeitsplatzkonzentration) Commission standard adopted in Europe. iv • Despite respirator inlet measurements for NDMA that were in excess of its OEL, all corresponding outlet measurements, from both respirator cartridges, were below analytical DL 1 for the

61 RADIATION PROTECTION AND DOSIMETRY↗

Hydraulic Testing of the Lost Lake Aquifer Near Recovery Well RWM019

An aquifer pumping test was conducted on the Lost Lake Aquifer Zone (LLAZ) at the recently installed recovery well RWM019 in accordance with the approved test plan (Dixon, 2020). The objective of the testing was to determine baseline well performance parameters and aquifer hydraulic conductivity. This testing consisted of a step-drawdown test to determine well performance properties, a constant pumping rate aquifer test to determine aquifer hydraulic properties, and a post-test aquifer recovery monitoring period also used to estimate aquifer hydraulic properties. Well performance parameters determined included specific capacity, well efficiency, and head loss coefficients. The specific capacity of RWM019 was determined to be approximately 2.6 gpm/ft of drawdown based on the final step of the step-drawdown test. Well efficiency was inversely related to pumping rate and decreased from 87% to 81% over a pumping range of approximately 49 to 79 gpm. The aquifer head loss coefficient was determined to be 2.3 ft/ft 3 /min and the well loss coefficient was determined to be 0.05 min 2 /ft 5 .

42 ENGINEERING↗