Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Temperature Stratification”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

Evolution of a Florida Cirrus Anvil

This paper presents a detailed study of a single thunderstorm anvil cirrus cloud measured on 21 July 2002 near southern Florida during the Cirrus Regional Study of Tropical Anvils and Cirrus Layers--Florida Area Cirrus Experiment (CRYSTAL-FACE). NASA WB-57F and University of North Dakota Citation aircraft tracked the microphysical and radiative development of the anvil for 3 h. Measurements showed that the cloud mass that was advected downwind from the thunderstorm was separated vertically into two layers: a cirrus anvil with cloud-top temperatures of -45?C lay below a second, thin tropopause cirrus (TTC) layer with the same horizontal dimensions as the anvil and temperatures near -70?C. In both cloud layers, ice crystals smaller than 50 ?m across dominated the size distributions and cloud radiative properties. In the anvil, ice crystals larger than 50 ?m aggregated and precipitated while small ice crystals increasingly dominated the size distributions; as a consequence, measured ice water contents and ice crystal effective radii decreased with time. Meanwhile, the anvil thinned vertically and maintained a stratification similar to its environment. Because effective radii were small, radiative heating and cooling were concentrated in layers approximately 100 m thick at the anvil top and base. A simple analysis suggests that the anvil cirrus spread laterally because mixing in these radiatively driven layers created horizontal pressure gradients between the cloud and its stratified environment. The TTC layer also spread but, unlike the anvil, did not dissipate--perhaps because the anvil shielded the TTC from terrestrial infrared heating. Calculations of top-of-troposphere radiative forcing above the anvil and TTC showed strong cooling that tapered as the anvil evolved.

Garrett, T. J.↗

Influence of Heat Flow from the Planetary Interior on Surface Habitability

an primordial and/or radiogenic heat flow from a rocky planet’s interior help maintain a surface environment amenable to life?On rocky Earth-like planets with shallow oceans (≤5 km depth) that are on the outer edge of the habitable zone, the additional energy provided might make the difference between a world supporting regional habitat space and a world uninhabitable by any known life-form. To test this hypothesis, we introduce heat flux from the planetary interior as a forcing to the NASA/GISSROCKE-3D exoplanet GCM, and explore whether it can enhance the habitability of marginal terrestrial rocky planets (e.g.,paleo Earth in a “snowball” climate state).GCM simulations of modern Earth have not included geothermal heat flux as a climate forcing, as it is more than an order of magnitude less than the 2.9 W/m heating caused by anthropogenic greenhouse gases [Flanner, GRL 2009]. Modern Earth measurements in the oceans [Downes et al., GRL 2019] and results from ocean GCMs [Barnes et al., Ocean Model. 2017]suggest that localized higher heat flux can have measurable thermodynamic and dynamic impacts, such as weakening deep ocean stratification and increased poleward ocean heat transports. A similar result with ROCKE-3D would be important, since our snowball Earth simulations without heat flux produce features like ocean stratification that should have hampered the survival of life. We have created a set of spatially variable geothermal heat fluxes at varying horizontal resolutions based on modern Earth heat flow patterns [Davies, Geochem. Geophys. Geosys. 2013] to test the sensitivity of the ROCKE-3D GCM initially in a modern Earth context. Preliminary results show that even modest heat fluxes have a measurable impact on deep ocean temperatures (upto +0.9°C locally) and that this heat can be transported at depth along ocean circulation paths. Estimates of heat flux impacts on vertical ocean mixing and surface ocean conditions require long simulations at the higher spatial resolutions needed to express heat flow at the scale of most ocean ridges. Ongoing simulations are focused on testing the impacts of horizontal resolution and flux scaling on surface environments, especially for “snowball” climate scenarios.

Heat flow↗

Integral Reactor Containment Condensation Model and Experimental Validation

This NEUP funded project, NEUP 12-3630, is for experimental, numerical and analytical studies on high-pressure steam condensation phenomena in a steel containment vessel connected to a water cooling tank, carried out at Oregon State University (OrSU) and the University of Wisconsin at Madison (UW-Madison). In the three years of investigation duration, following the original proposal, the planned tasks have been completed: (1) Performed a scaling study for the full pressure test facility applicable to the reference design for the condensation heat transfer process during design basis accidents (DBAs), modified the existing test facility to route the steady-state secondary steam flow into the high pressure containment for controllable condensation tests, and extended the operations at negative gage pressure conditions (OrSU). (2) Conducted a series of DBA and quasi-steady experiments using the full pressure test facility to provide a reliable high pressure condensation database (OrSU). (3) Analyzed experimental data and evaluated condensation model for the experimental conditions, and predicted the prototypic containment performance under accidental conditions (UW-Madison). A film flow model was developed for the scaling analysis, and the results suggest that the 1/3 scaled test facility covers large portion of laminar film flow, leading to a lower average heat transfer coefficient comparing to the prototypic value. Although it is conservative in reactor safety analysis, the significant reduction of heat transfer coefficient (50%) could under estimate the prototypic condensation heat transfer rate, resulting in inaccurate prediction of the decay heat removal capability. Further investigation is thus needed to quantify the scaling distortion for safety analysis code validation. Experimental investigations were performed in the existing MASLWR test facility at OrST with minor modifications. A total of 13 containment condensation tests were conducted for pressure ranging from 4 to 21 bar with three different static inventories of non-condensable gas. Condensation and heat transfer rates were evaluated employing several methods, notably from measured temperature gradients in the HTP as well as measured condensate formation rates. A detailed mass and energy accounting was used to assess the various measurement methods and to support simplifying assumptions required for the analysis. Condensation heat fluxes and heat transfer coefficients are calculated and presented as a function of pressure to satisfy the objectives of this investigation. The major conclusions for those tests are summarized below: (1) In the steam blow-down tests, the initial condensation heat transfer process involves the heating-up of the containment heat transfer plate. An inverse heat conduction model was developed to capture the rapid transient transfer characteristics, and the analysis method is applicable to SMR safety analysis. (2) The average condensation heat transfer coefficients for different pressure conditions and non-condensable gas mass fractions were obtained from the integral test facility, through the measurements of the heat conduction rate across the containment heat transfer plate, and from the water condensation rates measurement based on the total energy balance equation. 15 (3) The test results using the measured HTP wall temperatures are considerably lower than popular condensation models would predict mainly due to the side wall conduction effects in the existing MASLWR integral test facility. The data revealed the detailed heat transfer characteristics of the model containment, important to the SMR safety analysis and the validation of associated evaluation model. However this approach, unlike separate effect tests, cannot isolate the condensation heat transfer coefficient over the containment wall, and therefore is not suitable for the assessment of the condensation heat transfer coefficient against system pressure and noncondensable gas mass fraction. (4) The average condensation heat transfer coefficients measured from the water condensation rates through energy balance analysis are appropriate, however, with considerable uncertainties due to the heat loss and temperature distribution on the containment wall. With the consideration of the side wall conduction effects, the results indicate that the measured heat transfer coefficients in the tests is about 20% lower than the prediction of Dehbi’s correlation, mainly due to the side wall conduction effects. The investigation also indicates an increase in the condensation heat transfer coefficient at high containment pressure conditions, but the uncertainties invoked with this method appear to be substantial. (5) Non-condensable gas in the tests has little effects on the condensation heat transfer at high elevation measurement ports. It does affect the bottom measurements near the water level position. The results suggest that the heavier non-condensable gas is accumulated in the lower portion of the containment due to stratification in the narrow containment space. The overall effects of the non-condensable gas on the heat transfer process should thus be negligible for tall containments of narrow condensation spaces in most SMR designs. Therefore, the previous correlations with noncondensable gas effects are not appropriate to those small SMR containments due to the very poor mixing of steam and non-condensable gas. The MELCOR simulation results agree with the experimental data reasonably well. However, it is observed that the MELCOR overpredicts the heat flux for all analyzed tests. The MELCOR predicts that the heat fluxes for CCT’s approximately range from 30 to 45 kW/m2 whereas the experimental data (averaged) ranges from about 25 to 40 kW/m2. This may be due to the limited availability of liquid film models included in MELCOR. Also, it is believed that due to complex test geometry, measured temperature gradients across the heat transfer plate may have been underestimated and thus the heat flux had been underestimated. The MELCOR model predicts a film thickness on the order of 100 microns, which agrees very well with film flow model developed in this study for scaling analysis. However, the expected differences in film thicknesses for near vacuum and near atmospheric test conditions are not significant. Further study on the behavior of condensate film is expected to refine the simulation results. Possible refinements include but are not limited to, the followings: CFD simulation focusing on the liquid film behavior and benchmarking with experimental analyses for simpler geometries. 16 1 INTRODUCTION This NEUP funded project, NEUP 12-3630, is for experimental, numerical and analytical studies on high-pressure steam condensation phenomena in a steel containment vessel connected to a water cooling tank, carried out at Oregon State University (OrSU) and the University of Wisconsin at Madison (UW-Madison). The experimental results are employed to validate the containment condensation model in reactor containment system safety analysis code for integral SMRs. Such a containment condensation model is important to demonstrate the adequate cooling. In the three years of investigation, following the original proposal, the following planned tasks have been completed: (1) Performed a scaling study for the full pressure test facility applicable to the reference design for the condensation heat transfer process during design basis accidents (DBAs), modified the existing test facility to route the steady-state secondary steam flow into the high pressure containment for controllable condensation tests, and extended the operations at negative gage pressure conditions (OrSU). (2) Conducted a series of DBA and quasi-steady experiments using the full pressure test facility to provide a reliable high pressure condensation database (OrSU). (3) Analyzed experimental data and evaluated condensation model for the experimental conditions, and predicted the prototypic containment performance under accidental conditions (UW-Madison). The results are applicable to integral Small Modular Reactor (SMR) designs, including NuScale, mPower, Westinghouse SMR, Holtec-160 and other integral reactors with small containments of relatively high pressures under accidental conditions. Testing has been conducted at the OrSU laboratory in the existing MASLWR (Multi-Application Small Light Water Reactor) integral test facility sponsored by the US Department of Energy. Its highpressure stainless steel containment model (~2 MPa) is scaled to the NuScale SMR currently under development at NuScale Power, Inc.. Minor modifications to the model containment have been made to control the non-condensable gas fraction and to utilize the secondary loop stable steam flow for condensation testing. UW-Madison has developed a containment condensation model, which leveraged previous validated containment heat transfer work carried out at UW-Madison, and extended the range of applicability of the model to integral SMR designs that utilize containment vessels of high heat transfer efficiencies. In this final report, the research background and literature survey are presented in Chapter 2 and 3, respectively. The test facility description and modifications are summarized in Chapter 4, and the scaling analysis is introduced in Chapter 5. The tests description, procedures, and data analysis are presented in Chapter 6, while the numerical modeling is presented in Chapter 7, followed by a conclusion section in Chapter 8.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

FULLY CONVECTIVE MAGNETOROTATIONAL TURBULENCE IN STRATIFIED SHEARING BOXES

We present a numerical study of turbulence and dynamo action in stratified shearing boxes with zero magnetic flux. We assume that the fluid obeys the perfect gas law and has finite (constant) thermal diffusivity. We choose radiative boundary conditions at the vertical boundaries in which the heat flux is proportional to the fourth power of the temperature. We compare the results with the corresponding cases in which fixed temperature boundary conditions are applied. The most notable result is that the formation of a fully convective state in which the density is nearly constant as a function of height and the heat is transported to the upper and lower boundaries by overturning motions is robust and persists even in cases with radiative boundary conditions. Interestingly, in the convective regime, although the diffusive transport is negligible, the mean stratification does not relax to an adiabatic state.

79 ASTRONOMY AND ASTROPHYSICS↗

Electrostriction of Near-Critical SF6 in Microgravity

We used interferometry to measure the electric-field-induced (i.e., "electrostrictive") increase of the density of sulfur hexafluoride near its critical point. The results at the temperatures T(sub c) + 5 mK, T(sub c) + 10 mK, and T(sub c) + 30 mK with T(sub c) = 319 K agree with a calculation based on the Clausius-Mossotti relation and the restricted cubic model equation of state. These measurements were performed in microgravity so that the electrostrictive density changes (less than or equal to 3.5% in this work) would not be complicated by stratification of the fluid's density induced by the Earth's gravity.

Zimmerli, G. A.↗

Creating an Advanced Sensor Network to calculate real-time, mass-weighted flue gas composition and air heater leakage of a coal-fired utility boiler under dynamic operating conditions

Utilization of renewable energy sources to minimize the environmental impact of energy production has changed the way utility boilers operate, requiring frequent load cycling between full load and partial loads as low as 30%. Dynamic operation of coal-fired utility boilers significantly reduces boiler efficiency when compared to steady state at full load. Data-driven plant optimization has shown success with coal-fired utility boilers under dynamic operating conditions. The purpose of this work was to create an Advanced Sensor Network (ASN) to provide more extensive real-time data to inform dynamic plant optimization of Net Unit Heat Rate (NUHR). The ASN consists of gas sampling grids in the convective pass of the boiler and downstream of the air heater. These sampling grids allow for quantification of spatial variation of flue gas within the boiler and calculation of mass-weighted composition of flue gas through the combination of composition, velocity, and temperature measurements. The comparison of O 2 between the inlet and outlet of the air heater is used to calculate air leakage in real time. Flue gas composition and air heater leakage are both important factors in boiler efficiency and NUHR. Further, the results of this work support the value of mass-weighted averages for determining flue gas composition accurately. The measurements from the ASN show increased composition stratification during dynamic operation, with an average standard deviation 38% higher than observed during steady-state operation. Air heater leakage was also observed to increase from 2.8% to 5.1% following a load change. Prior to the installation of the ASN, these data would not have been available for dynamic control. These real-time data will be leveraged to calculate and optimize for NUHR during dynamic operation in future work.

42 ENGINEERING↗

Experimental verification of scaling parameters for thermal stratification

A study to determine important dimensionless parameters associated with thermal stratification of a heated container of liquid, and the pressure history of its vapor, was performed. Analysis of the governing equations identified the modified Grashoff number, the modified Fourier number, and the interface number as the dominant dimensionless parameters associated with this process. A test program designed to verify the validity of these scaling parameters was executed. The quality of scaling was checked by comparing the dimensionless pressures and temperatures for scaled pairs of tests. Results indicate that the bulk liquid temperature, the surface temperature of the liquid, and the tank pressure can be scaled with the three dimensionless parameters. Some deviations were found in the detailed temperature profiles between the scaled pairs of tests.

Ji, H.-C.↗

Probing eddy size and its effective mixing length in stably stratified roughness sublayer flows

Stably stratified roughness sublayer flows are ubiquitous yet remain difficult to represent in models and to interpret using field experiments. Here, continuous high-frequency potential temperature profiles from the forest floor up to 6.5 times the canopy height observed with distributed temperature sensing (DTS) are used to link eddy topology to roughness sublayer stability correction functions and coupling between air layers within and above the canopy. The experiments are conducted at two forest stands classified as hydrodynamically sparse and dense. Near-continuous profiles of eddy sizes (length scales) and effective mixing lengths for heat are derived from the observed profiles using a novel conditional sampling approach. The approach utilizes potential temperature isoline fluctuations from a statically stable background state. The transport of potential temperature by an observed eddy is assumed to be conserved (adiabatic movement) and we assume that irreversible heat exchange between the eddy and the surrounding background occurs along the (vertical) periphery of the eddy. This assumption is analogous to Prandtl's mixing-length concept, where momentum is transported rapidly vertically and then equilibrated with the local mean velocity gradient. A distinct dependence of the derived length scales on background stratification, height above ground, and canopy characteristics emerges from the observed profiles. Implications of these findings for (1) the failure of Monin–Obukhov similarity in the roughness sublayer and (2) above-canopy flow coupling to the forest floor are examined. The findings have practical applications in terms of analysing similar DTS data sets with the proposed approach, modelling roughness sublayer flows, and interpreting nocturnal eddy covariance measurements above tall forested canopies.

54 ENVIRONMENTAL SCIENCES↗

Seasonal and Interannual Variability of Tidal Mixing Signatures in Indonesian Seas from High-Resolution Sea Surface Temperature

With their complex narrow passages and vigorous mixing, the Indonesian seas provide the only low-latitude pathway between the Pacific and Indian Oceans and thus play an essential role in regulating Pacific-Indian Ocean exchange, regional air-sea interaction, and ultimately, global climate phenomena. While previous investigations using remote sensing and numerical simulations strongly suggest that this mixing is tidally driven, the impacts of monsoon and El Niño Southern Oscillation (ENSO) on tidal mixing in the Indonesian seas must play an important role. Here we use high-resolution sea surface temperature from June 2002 to June 2021 to reveal monsoon and ENSO modulations of mixing. The largest spring-neap (fortnightly) signals are found to be localized in the narrow passages/straits and sills, with more vigorous tidal mixing during the southeast (boreal summer) monsoon and El Niño than that during the northwest (boreal winter monsoon) and La Niña. Therefore, tidal mixing, which necessarily responds to seasonal and interannual changes in stratification, must also play a feedback role in regulating seasonal and interannual variability of water mass transformations and Indonesian throughflow. The findings have implications for longer-term variations and changes of Pacific–Indian ocean water mass transformation, circulation, and climate.

Indonesian seas↗

First Detection of a Strong Magnetic Field on a Bursty Brown Dwarf: Puzzle Solved

We report the first direct detection of a strong, 5 kG magnetic field on the surface of an active brown dwarf. LSR J1835+3259 is an M8.5 dwarf exhibiting transient radio and optical emission bursts modulated by fast rotation. We have detected the surface magnetic field as circularly polarized signatures in the 819 nm sodium lines when an active emission region faced the Earth. Modeling Stokes profiles of these lines reveals the effective temperature of 2800 K and log gravity acceleration of 4.5. These parameters place LSR J1835+3259 on evolutionary tracks as a young brown dwarf with the mass of 55±4M{sub J} and age of 22 ± 4 Myr. Its magnetic field is at least 5.1 kG and covers at least 11% of the visible hemisphere. The active region topology recovered using line profile inversions comprises hot plasma loops with a vertical stratification of optical and radio emission sources. These loops rotate with the dwarf in and out of view causing periodic emission bursts. The magnetic field is detected at the base of the loops. This is the first time that we can quantitatively associate brown dwarf non-thermal bursts with a strong, 5 kG surface magnetic field and solve the puzzle of their driving mechanism. This is also the coolest known dwarf with such a strong surface magnetic field. The young age of LSR J1835+3259 implies that it may still maintain a disk, which may facilitate bursts via magnetospheric accretion, like in higher-mass T Tau-type stars. Our results pave a path toward magnetic studies of brown dwarfs and hot Jupiters.

79 ASTRONOMY AND ASTROPHYSICS↗

RADIATIVE AND DYNAMIC STABILITY OF A DILUTE PLASMA

We analyze the linear stability of a dilute, hot plasma, taking into account the effects of stratification and anisotropic thermal conduction. The work is motivated by attempts to understand the dynamics of the intracluster medium in galaxy clusters. We show that magnetic field configurations that nominally stabilize either the heat-flux driven buoyancy instability (associated with a positive thermal gradient) or the magnetothermal instability (negative thermal gradient) can lead to previously unrecognized g-mode overstabilities. The driving source of the overstability is either radiative cooling (positive temperature gradient) or the heat flux itself (negative temperature gradient). While the implications of these overstabilities have yet to be explored, we speculate that the cold fronts observed in many relaxed galaxy clusters may be related to their nonlinear evolution.

79 ASTRONOMY AND ASTROPHYSICS↗

Baroclinic instability of a rotating Hadley cell

The stability of a thin fluid layer between two rotating plates which are subjected to a horizontal temperature gradient is investigated. The solution for the stationary basic state is obtained in a closed form. It is pointed out that this solution identifies Ekman and thermal layers adjacent to the plates and interior temperature and velocity fields which are almost linear functions of height. The stability of that basic state with respect to infinitesimal zonal waves is then analyzed via the solution of the complete viscous linear equations for the perturbations. The character of the growth rates is found to be similar to those of the classical baroclinic waves. It is also found that the region of stability depends on the Prandtl number, the vertical stratification parameter, and both the meridional and zonal wavenumbers. The flow is generally unstable for small enough Ekman numbers and for Rossby numbers less than 10.

Antar, B. N.↗

On the Nature of the Arctic’s Positive Lapse-rate Feedback: Cause or Symptom of Arctic Amplification

Radiative energy fluxes exiting the atmosphere towards the surface and to space are sensitive to the vertical structure of temperature. Under anthropogenic forcing, this sensitivity gives rise to the lapse-rate feedback. Shown to be negative in the tropics and positive in the Arctic, studies argue that the lapse-rate feedback is the primary cause of Arctic Amplification. While mechanistically the negative tropical lapse-rate feedback is understood, the mechanics of the positive Arctic lapse-rate feedback are less clear. Previous arguments state that the Arctic’s stable stratification is the origin of its positive lapse-rate feedback. We present results using CMIP5 and CMIP6 model output that arguing that the magnitude, spatial variability, seasonality, and inter-model spread in the Arctic lapse-rate feedback is controlled by surface properties and atmosphere-ocean-sea ice energy exchanges, not the degree of stable stratification. We argue that the Arctic’s positive lapse-rate feedback is a seasonal and regional phenomenon that manifests from local surface characteristics and surface albedo, ice insulation, and thermal inertia feedbacks that cause surface warming to outpace atmospheric warming in sea ice-retreat regions. We view the Arctic’s positive lapse-rate feedback as a symptom rather than the primary cause of Arctic Amplification.

Patrick Charles Taylor↗

On the Nature of the Arctic’s Positive Lapse Rate Feedback Cause or Symptom of Arctic Amplification

Radiative energy fluxes exiting the atmosphere towards the surface and to space are sensitive to the vertical structure of temperature. Under anthropogenic forcing, this sensitivity gives rise to the lapse-rate feedback. Shown to be negative in the tropics and positive in the Arctic, studies argue that the lapse-rate feedback is the primary cause of Arctic Amplification. While mechanistically the negative tropical lapse-rate feedback is understood, the mechanics of the positive Arctic lapse-rate feedback are less clear. Previous arguments state that the Arctic’s stable stratification is the origin of its positive lapse-rate feedback. We present results using CMIP5 and CMIP6 model output that arguing that the magnitude, spatial variability, seasonality, and inter-model spread in the Arctic lapse-rate feedback is controlled by surface properties and atmosphere-ocean-sea ice energy exchanges, not the degree of stable stratification. We argue that the Arctic’s positive lapse-rate feedback is a seasonal and regional phenomenon that manifests from local surface characteristics and surface albedo, ice insulation, and thermal inertia feedbacks that cause surface warming to outpace atmospheric warming in sea ice-retreat regions. We view the Arctic’s positive lapse-rate feedback as a symptom rather than the primary cause of Arctic Amplification.

Patrick C Taylor↗

A Comparative Experimental Analysis of Natural Gas Dual Fuel Combustion Ignited by Diesel and Poly OxyMethylene Dimethyl Ether

Dual-fuel low-temperature combustion is a possible solution for alleviating the tradeoff between oxides of nitrogen and soot emissions in conventional diesel combustion, albeit with poor combustion stability, high carbon monoxide, and unburned hydrocarbon emissions at low engine loads. The present work compares emissions and combustion (heat release and other metrics) of both diesel and poly-oxy methylene dimethyl ether as high-reactivity fuels to ignite natural gas while leveraging spray-targeted reactivity stratification, which involved multiple injections of the high-reactivity fuels. The experiments included six parametric sweeps of: (1) start of first injection, (2) start of second injection, (3) percentage of energy substitution of natural gas, (4) commanded injection duration ratio, (5) rail pressure, and (6) intake pressure. The experiments were performed on a 1.8 L heavy-duty single-cylinder research engine operating at a medium speed of 1339 rev/min. Not-to-exceed limits for the indicated oxides of nitrogen emissions, maximum pressure rise rate, and the coefficient of variation of the indicated mean effective pressure were set to 1 g/kWh, 10 bar/CAD, and 10%, respectively. The indicated emissions decreased and combustion improved significantly for both fueling combinations when the experimental procedure was applied.

Partridge, Kendyl Ryan↗

Evidence of Mixed Scaling for Mean Profile Similarity in the Stable Atmospheric Surface Layer

A new mixed scaling parameter Z = z/(Lh)1/2 is proposed for similarity in the stable atmospheric surface layer, where z is the height, L is the Obukhov length, and h is the boundary layer depth. In comparison with the parameter ζ = z/L from Monin–Obukhov similarity theory (MOST), the new parameter Z leads to improved mean profile similarity for wind speed and air temperature in large-eddy simulations. It also yields the same linear similarity relation for CASES-99 field measurements, including in the strongly stable (but still turbulent) regime where large deviations from MOST are observed. Results further suggest that similarity for turbulent energy dissipation rate depends on both Z and ζ. The proposed mixed scaling of Z and relevance of h can be explained by physical arguments related to the limit of z-less stratification that is reached asymptotically above the surface layer. The presented evidence and fitted similarity relations are promising, but the results and arguments are limited to a small sample of idealized stationary stable boundary layers. Here, corroboration is needed from independent datasets and analyses, including for complex and transient conditions not tested here.

54 ENVIRONMENTAL SCIENCES↗

Energy, volatile production, and climatic effects of the Chicxulub Cretaceous/Tertiary impact

A comprehensive analysis of volatiles in the Chicxulub impact strongly supports the hypothesis that impact-generated sulfate aerosols caused over a decade of global cooling, acid rain, and disruption of ocean circulation, which contributed to the mass extinction at the Cretaceous/Tertiary (K/T) boundary. The crater size, meteoritic content of the K/T boundary clay, and impact models indicate that the Chicxulub crater was formed by a short period comet or an asteroid impact that released 0.7-3.4 x 10(31) ergs of energy. Impact models and experiments combined with estimates of volatiles in the projectile and target rocks predict that over 200 gigatons (Gt) each of SO2 and water vapor, and over 500 Gt of CO2, were globally distributed in the stratosphere by the impact. Additional volatiles may have been produced on a global or regional scale that formed sulfate aerosols rapidly in cooler parts of the vapor plume, causing an early, intense pulse of sulfuric acid rain. Estimates of the conversion rate of stratospheric SO2 and water vapor to sulfate aerosol, based on volcanic production of sulfate aerosols, coupled with calculations of diffusion, coagulation, and sedimentation, demonstrate that the 200 Gt stratospheric SO2 and water vapor reservoir would produce sulfate aerosols for 12 years. These sulfate aerosols caused a second pulse of acid rain that was global. Radiative transfer modeling of the aerosol clouds demonstrates (1) that if the initial rapid pulse of sulfate aerosols was global, photosynthesis may have been shut down for 6 months and (2) that for the second prolonged aerosol cloud, solar transmission dropped 80% by the end of first year and remained 50% below normal for 9 years. As a result, global average surface temperatures probably dropped between 5 degrees and 31 degrees K, suggesting that global near-freezing conditions may have been reached. Impact-generated CO2 caused less than 1 degree K greenhouse warming and therefore was insignificant compare to the sulfate cooling. The magnitude of sulfate cooling depends largely upon the rate of ocean mixing as surface waters cool, sink, and are replaced by upwelling of deep ocean water. This upwelling apparently drastically altered ocean stratification and circulation, which may explain the global collapse of the delta 13C gradient between surface and deep ocean waters at the K/T boundary.

NASA Center JPL↗

A control-oriented combustion model framework for compression ignition engines operating on low-reactivity fuel

This work focuses on zero-dimensional modeling of the heat release rate in a compression ignition engine operating on gasoline-like fuels. Due to the properties of gasoline, such as high volatility and longer ignition delay than diesel, the injection strategies can vary significantly from the operation with conventional diesel fuel. Different injection strategies are commonly used to achieve varying degrees of in-cylinder stratification in order to shape the combustion event and maximize efficiency. The proposed zero-dimensional combustion model was developed to account for the different stages in combustion caused by the fuel stratification. As the ignition delay model is an integral part of the entire combustion process and significantly affects the prediction accuracy, special attention has been paid to local phenomena influencing ignition delay. A one-dimensional spray model by Musculus and Kattke was employed in conjunction with a Lagrangian tracking approach in order to estimate the local air–fuel ratio within the spray tip, as a proxy for reactivity. The local air–fuel ratio, in-cylinder temperature and pressure were used in an integral fashion to estimate the ignition delay. Heat release rates were modeled using first-order non-linear differential equations. The proposed combustion model was validated against experimental data of a heavy-duty compression ignition engine with up to three injection events at mostly 1038 r/min and 14 bar brake mean effective pressure. Further validation of the model was carried out at other engine loads and speeds. Model prediction errors in CA50 of less than 1 °CA across all conditions were found. Modeling results of other combustion metrics such as combustion duration and indicated mean effective pressure are also highly satisfactory. In addition, the model has been shown to be capable of estimating the ringing intensity for most conditions.

Pamminger, Michael↗