Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Tank Farm”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

PROBABILITY BASED CORROSION CONTROL FOR LIQUID WASTE TANKS - PART III

The liquid waste chemistry control program is designed to reduce the pitting corrosion occurrence on tank walls. The chemistry control program has been implemented, in part, by applying engineering judgment safety factors to experimental data. However, the simple application of a general safety factor can result in use of excessive corrosion inhibiting agents. The required use of excess corrosion inhibitors can be costly for tank maintenance, waste processing, and in future tank closure. It is proposed that a probability-based approach can be used to quantify the risk associated with the chemistry control program. This approach can lead to the application of tank-specific chemistry control programs reducing overall costs associated with overly conservative use of inhibitor. Furthermore, when using nitrite as an inhibitor, the current chemistry control program is based on a linear model of increased aggressive species requiring increased protective species. This linear model was primarily supported by experimental data obtained from dilute solutions with nitrate concentrations less than 0.6 M, but is used to produce the current chemistry control program up to 1.0 M nitrate. Therefore, in the nitrate space between 0.6 and 1.0 M, the current control limit is based on assumptions that the linear model developed from data in the <0.6 M region is applicable in the 0.6-1.0 M region. Due to this assumption, further investigation of the nitrate region of 0.6 M to 1.0 M has potential for significant inhibitor reduction, while maintaining the same level of corrosion risk associated with the current chemistry control program. Ongoing studies have been conducted in FY07, FY08, FY09 and FY10 to evaluate the corrosion controls at the SRS tank farm and to assess the minimum nitrite concentrations to inhibit pitting in ASTM A537 carbon steel below 1.0 molar nitrate. The experimentation from FY08 suggested a non-linear model known as the mixture/amount model could be used to predict the probability of corrosion in ASTM A537 in varying solutions as shown in Figure 1. The mixture/amount model takes into account not only the ratio (or mixture) of inhibitors and aggressive species, but also the total concentration (or amount) of species in a solution. Historically, the ratio was the only factor taken into consideration in the development of the current chemistry control program. During FY09, an experimental program was undertaken to refine the mixture/amount model by further investigating the risk associated with reducing the minimum molar nitrite concentration required to confidently inhibit pitting in dilute solutions. The results of FY09, as shown in Figure 2, quantified the probability for a corrosion free outcome for combinations of nitrate and nitrite. The FY09 data predict probabilities up to 70%. Additional experimental data are needed to increase the probability to an acceptable percentage.

36 MATERIALS SCIENCE↗

WM26 Paper Multi-Robot Collaboration for Hazardous Environments

Hazardous nuclear and industrial facilities are rarely designed for robots. Work in these domains demand precise manipulation and robust mobility in cluttered, constrained spaces where off-the-shelf platforms struggle and “one-size-fits-all” machines become costly and complex. Idaho National Laboratory (INL) is developing an autonomous, multi-robot inspection system that coordinates task-specific platforms rather than relying on a single omni-tool robot. An electric truck serves as a power and compute hub for a custom manipulator co-developed with Florida International University (FIU), a commercial mini crawler, a pan–tilt–zoom camera, and a Nexxis Argus LiDAR mapping system. Working in concert, these robots generate spatial, radiation, and temperature maps of the pit environments at the Hanford Waste Tank Farms. These systems will capture visual records and environmental telemetry to allow for analysis post inspection. The system architecture uses Robot Operating System 2 (ROS 2) for publish/subscribe integration, NVIDIA Isaac Sim and Unity for simulation and visualization, and algorithms such as NVBlox to fuse data into unified 3D overlays. This robot-agnostic approach reduces operator burden by enabling autonomy across heterogeneous platforms and lets each robot be used where it is strongest. Having autonomous functions means operators don’t have to fully control multiple different components. The ease of use could allow for more widespread adoption of advanced robotics at waste management sites that see continued use. By coordinating simpler, purpose-built mechanisms, the approach lowers design and manufacturing complexity, reduces capital risk in contaminated settings, and improves controllability for complex inspection and manipulation tasks. We present the architecture, early results, and lessons learned from building and deploying this coordinated multi-robot system, with the goal of accelerating safe, cost-effective adoption of advanced robotics at waste-management sites.

42 - ENGINEERING↗

Proposed Risk-Based Approach for Nitrosamine Chemicals of Potential Concern

This report documents the re-evaluation of Hanford Tank Farm (HTF) occupational exposure limits (OEL) for five N-nitrosamines identified as Chemicals of Potential Concern (COPC), and two other N-nitrosamines being considered as COPCs. N-nitrosamines are genotoxic, and exposure has been historically regulated based on cancer as the endpoint of concern. Currently, HTF OELs are based on German Maximum Arbeitsplatz Konzentration values that are no longer used. The National Institute of Occupational Safety and Health (NIOSH) recently released new policy applying a risk-based approach to develop OELs for occupational carcinogens and plans to release guidance on specific chemicals in the future. Consistent with this new NIOSH policy, Pacific Northwest National Laboratory proposes a risk-based approach to establish risk-specific doses for occupational exposures to N-nitrosamine COPCs. This approach establishes a range of N-nitrosamine inhalation exposures associated with risk levels that can be used as a tool for protecting HTF workers. Updated guidance from NIOSH or other authoritative bodies on N-nitrosamine OELs should trigger a re-evaluation of this proposed approach.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Direct Feed Low Activity Waste Integrated Permitting - 16642

An overall Hanford permitting strategy for the U. S. Department of Energy (DOE) Office of River Protection (ORP) is being developed to support the Direct Feed Low- Activity Waste (DFLAW) Program. The strategy identifies new permits and modifications of existing permits, as well as major regulatory approvals to support the startup and operation of nuclear systems necessary to feed low activity tank waste, pretreat the waste, operate the Waste Treatment and Immobilization Plant (WTP) Low Activity Waste (LAW) facility to treat tank waste, and dispose of waste streams. Types of permits include hazardous waste, toxic air, and radiological air licenses. Four different Contractors manage operations at Tank Farms, WTP, Utilities/Infrastructure, and Waste Disposal. Due to this complexity and the number of interfaces required, the need to have a strategic overview of all permits was evident. Approximately 25 permits and 4 major regulatory approvals are identified to implement DFLAW. The strategy will help guide integrated planning, scheduling and sequencing of permits and regulatory approvals to support DOE ORP's overall schedule for construction, commissioning and operation of DFLAW. Development of the strategy included extensive collaboration and coordination of an Integrated Permitting Team with staff and management representation from DOE, CH2M Hill Plateau Remediation Contractor (CHPRC), Washington River Protection Solutions LLC (WRPS), and Bechtel National Inc. (BNI). Information sessions and briefings have been conducted with the Washington State Department of Ecology (Ecology) and Washington State Department of Health (DOH) in the development of this overall strategy. Additionally, interface meetings are held with Ecology and DOH on specific projects early in the design phase to validate the permitting approach, identify key issues and information, and discuss requirements and assumptions. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Preliminary Study of Strong-Sludge Gas Retention and Release Mechanisms in Clay Simulants

The Hanford Site has 28 double-shell tanks (DSTs) and 149 single-shell tanks (SSTs) containing radioactive wastes that are complex mixes of radioactive and chemical products. The mission of the Department of Energy’s River Protection Project is to retrieve and treat the Hanford tank waste for disposal and close the tank farms. A key aspect of the mission is to retrieve and transfer waste from the SSTs, which are at greater risk for leaking, into DSTs for interim storage until the waste is transferred to and treated in the Waste Treatment and Immobilization Plant. There is, however, limited space in the existing DSTs to accept waste transfers from the SSTs, and approaches to overcoming the limited DST space will benefit the overall mission. The purpose of this study is to summarize and analyze the key previous experiment that forms the basis for the relaxed controls and to summarize initial progress and results on new experiments focused on understanding the conditions that result in low gas retention. The work is ongoing; this report provides a summary of the initial findings. The previous large-scale test used about 50 m3 of sediment, which would be unwieldy for doing multiple parametric experiments. Accordingly, experiments will begin with smaller-scale tests to determine whether the desired mechanisms can be studied without the difficulty of conducting very large experiments.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

DECONTAMINATION FACTORS AND FILTRATION FLUX IMPACT TO ARP AT REDUCED MST CONCENTRATION

Tank Farm and Closure Engineering is evaluating changes to the Actinide Removal Process facility operations to decrease the MST concentration from 0.4 g/L to 0.2 g/L and the contact time from 12 hours to between 6 and 8 hours. For this evaluation, SRNL reviewed previous datasets investigating the performance of MST at 0.2 g/L in salt solutions ranging from 4.5 to 7.5 M in sodium concentration. In general, reducing the MST concentration from 0.4 to 0.2 g/L and increasing the ionic strength from 4.5 to 7.5 M in sodium concentration will decrease the measured decontamination factors for plutonium, neptunium, uranium and strontium. The decontamination factors as well as single standard deviation values for each sorbate are reported. These values are applicable within the sorbate and sodium concentrations used in the experimental measurements. Decreasing the MST concentration in the ARP from 0.4 g/L to 0.2 g/L will produce an increase in the filter flux, and could lead to longer operating times between filter cleaning. The increase in flux is a function of a number of operating parameters, and is difficult to quantify. However, it is estimated that the reduction in MST could result in a reduction of filtration time of up to 20%.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Development of a Conditioned System-Level Groundwater Model to Evaluate Long-Term Groundwater Impacts within a Performance Assessment - 20115

A preliminary performance assessment (PA) of single-shell tank Waste Management Area (WMA) A-AX located at the U.S. Department of Energy (DOE)'s Hanford Site in southeastern Washington is being conducted to satisfy the requirements of DOE Order 435.1 [1] as it relates to closure of the single-shell radioactive waste tanks in the WMA A-AX tank farms. A PA assesses the fate, transport, and impacts of radionuclides within a low-level radioactive waste disposal facility in its assumed closure configuration and the subsequent potential doses to humans over a 1,000-year compliance period and a 10,000-year performance evaluation period. The WMA A-AX preliminary PA evaluation is structured around the complementary use of process-level and system-level models to calculate the facility performance against established DOE Order 435.1 [1] performance objectives. Process-level models are those that represent a detailed phenomenological representation of processes of concern in the PA. Process models typically only represent one or a few of the components of the PA, such as groundwater flow and transport, and must be integrated with other modeling elements to perform PA calculations. System-level models are those that are abstracted from the process models, retaining the essential features of the process model, while allowing integration of all aspects of the PA in a single modeling framework. System-level models are often characterized by coarser numerical discretization, lower dimensionality, or other similar simplifications compared to the process-level model. Traditionally, a three-dimensional (3-D) process-level model is utilized primarily to evaluate the long-term impact on groundwater and the potential doses to individuals who consume contaminated groundwater. System-level models are also utilized to evaluate the groundwater pathway in PAs. These models typically have reduced dimensionality (1-D) and are conditioned utilizing flow fields (Darcy fluxes) and moisture content distributions that are abstracted from the process level models. The abstraction approach assures that the flow field in both models is consistent for a specific set of input parameters for flow, differing only in the discretization and dimensionality of the two models. The preliminary WMA A-AX PA incorporates a detailed representation of the geological system and hydraulic properties within the 3-D model STOMP{sup C} numerical code so that the effects of relevant features and processes on water flow and radionuclide transport in the subsurface can be evaluated. The complementary system-level model is developed utilizing the GoldSim{sup C} code to implement a simplified, 1-D equivalent model to represent the groundwater pathway. Contaminant transport through the vadose zone and unconfined aquifer for Tc-99 and I-129 were evaluated in each of the models. Adjustments to the saturated portion of the GoldSim{sup C} 1-D model were required to mimic the dispersion effect captured with the 3-D STOMP{sup C} model. Once this conditioning was conducted, highly similar results for the transport of Tc-99 and I-129 were achieved at the point of calculation, located 100 m downgradient from the WMA A-AX fenceline. These radionuclides represent elements that are regarded as primary dose drivers in the PA groundwater pathway analysis. The high degree of conformance between the two models suggests that the use of the equivalent 1-D system model is suitable for evaluating the full suite of radionuclides that will be released from the tank sources within WMA A-AX over the 1,000-year compliance period and over the 10,000-year evaluation period. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Real-time Erosion-Corrosion Detection in Waste Transfer Pipelines using Guided Wave Ultrasonic Sensors - 18368

A Fitness-for-Service (FFS) program for the Waste Transfer System has been implemented by the United States Department of Energy Hanford Site Tank Farm to examine structural parameters of the waste transfer systems in order to develop erosion/corrosion rates for relevant system components. The FFS information is acquired from opportunistic evaluations of pipelines that have been removed from service. The objective is to deliver more realistic estimates to the remaining useful life of the components and incorporate those estimates into future design/testing plans across the DOE complex. To aid to this objective, previous efforts at Hanford included the installation of sensors on some of the POR 104 components, to provide real time pipe wall thickness measurements. Due to certain limitations, alternative approaches for remote permanently mounted pipe wall ultrasonic thickness measurement systems have been investigated by FIU. Present research work is a supportive effort by FIU-ARC for DOE and WRPS, which investigates the option for remote-permanently mount guided wave ultrasonic transducer (UT) systems for HLW pipe wall thickness measurements. Specific applications include straight sections, elbows and other fittings used in jumper pits, evaporators, and valve boxes. The proposed method will provide information that will assist engineers with understanding the failure potential of HLW transfer components due to corrosion and erosion. This information can assist in determining if and when lines need to be removed, saving time and resources on the unneeded excavation of transfer lines. This information will also assist engineers with designing new transfer systems by establishing more detailed/accurate guidelines governing the life expectancy of the transfer system and its components. In the previous work, FIU has investigated the use of various ultrasonic systems that are either commercially available or used previously at Hanford and selected the most promising systems for further evaluation. The down-selected system is the guided wave UT sensor system from Permasense which is a UK based manufacturer. It is an integrated wireless sensor network system which used a patented technology for the acoustic wave propagation and has proven applications in the oil and gas industries. Scope of the present research includes the initial verification and validation of the Permasense Guided Wave sensor system as a potential erosion/corrosion detection system for carbon steel pipelines under static conditions. In future, the real-time erosion/corrosion detection will be investigated by measuring the thinning of the pipe sections by circulating simulants and continuous monitoring. This is achieved by passing abrasive and caustic solutions through an in-house designed pipe loop system. Results obtained provide realistic wear rates on 2 inch and 3 inch carbon steel pipes with straight sections and elbows using the Permasense UT sensor system. Thus, the present research delivers solutions for sensor evaluations, conducts bench scale testing followed by data acquisition and analysis for corrosion and erosion assessment. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

NEUTRALIZATIONS OF HIGH ALUMINUM LOW URANIUM USED NUCLEAR FUEL SOLUTIONS CONTAINING GADOLINIUM AS A NEUTRON POISON

H-Canyon will begin dissolving High Aluminum - Low Uranium (High Al/Low U) Used Nuclear Fuel (UNF) following approval by DOE which is anticipated in CY2011. High Al/Low U is an aluminum/enriched uranium UNF with small quantities of uranium relative to aluminum. The maximum enrichment level expected is 93% {sup 235}U. The High Al/Low U UNF will be dissolved in H-Canyon in a nitric acid/mercury/gadolinium solution. The resulting solution will be neutralized and transferred to Tank 39H in the Tank Farm. To confirm that the solution generated could be poisoned with Gd, neutralized, and discarded to the Savannah River Site (SRS) high level waste (HLW) system without undue nuclear safety concerns the caustic precipitation of simulant solutions was examined. Experiments were performed with three simulant solutions representative of the H-Canyon estimated concentrations in the final solutions after dissolution. The maximum U, Gd, and Al concentration were selected for testing from the range of solution compositions provided. Simulants were prepared in three different nitric acid concentrations, ranging from 0.5 to 1.5 M. The simulant solutions were neutralized to four different endpoints: (1) just before a solid phase was formed (pH 3.5-4), (2) the point where a solid phase was obtained, (3) 0.8 M free hydroxide, and (4) 1.2 M free hydroxide, using 50 wt % sodium hydroxide (NaOH). The settling behavior of the neutralized solutions was found to be slower compared to previous studies, with settling continuing over a one week period. Due to the high concentration of Al in these solutions, precipitation of solids was observed immediately upon addition of NaOH. Precipitation continued as additional NaOH was added, reaching a point where the mixture becomes almost completely solid due to the large amount of precipitate. As additional NaOH was added, some of the precipitate began to redissolve, and the solutions neutralized to the final two endpoints mixed easily and had expected densities of typical neutralized waste. Based on particle size and scanning electron microscopy analyses, the neutralized solids were found to be homogeneous and less than 20 microns in size. The majority of solids were less than 4 microns in size. Compared to previous studies, a larger percentage of the Gd was found to precipitate in the partially neutralized solutions (at pH 3.5-4). In addition the Gd:U mass ratio was found to be at least 1.0 in all of the solids obtained after partial or full neutralization. The hydrogen to U (H:U) molar ratios for two accident scenarios were also determined. The first was for transient neutralization and agitator failure. Experimentally this scenario was determined by measuring the H:U ratio of the settled solids. The minimum H:U molar ratio for solids from fully neutralized solutions was 388:1. The second accident scenario is for the solids drying out in an unagitiated pump box. Experimentally, this scenario was determined by measuring the H:U molar ratio in centrifuged solids. The minimum H:U atom ratios for centrifuged precipitated solids was 250:1. It was determined previously that a 30:1 H:Pu atom ratio was sufficient for a 1:1 Gd:Pu mass ratio. Assuming a 1:1 equivalence with {sup 239}Pu, the results of these experiments show Gd is a viable poison for neutralizing U/Gd solutions with the tested compositions.

08 HYDROGEN↗

ALTERNATIVE AND ENHANCED CHEMICAL CLEANING: CORROSION STUDIES RESULTS: FY2010

Due to the need to close High Level Waste storage tanks, chemical cleaning methods are needed for the removal of sludge heel materials remaining at the completion of mechanical tank cleaning efforts. Oxalic acid is considered the preferred cleaning reagent for heel dissolution of iron-based sludge. However, the large quantity of chemical reagents added to the tank farm from oxalic acid based cleaning has significant downstream impacts. Optimization of the oxalic acid cleaning process can potentially reduce the downstream impacts from chemical cleaning. To optimize oxalic acid usage, a detailed understanding of the chemistry of oxalic acid based sludge dissolution is required. Additionally, other acidic systems may be required for specific waste components that have low solubility in oxalic acid, and as a means to reduce oxalic acid usage in general. Electrochemical corrosion studies were conducted with 1 wt. % oxalic acid at mineral acid concentrations above and below the optimal conditions for this oxalic acid concentration. Testing environments included pure reagents, pure iron and aluminum phases, and sludge simulants. Mineral acid concentrations greater than 0.2 M and temperatures greater than 50 C result in unacceptably high corrosion rates. Results showed that manageable corrosion rates of carbon steel can be achieved at dilute mineral acid concentrations (i.e. less than 0.2 M) and low temperatures based on the contact times involved. Therefore, it is recommended that future dissolution and corrosion testing be performed with a dilute mineral acid and a less concentrated oxalic acid (e.g., 0.5 wt.%) that still promotes optimal dissolution. This recommendation requires the processing of greater water volumes than those for the baseline process during heel dissolution, but allows for minimization of oxalic acid additions. The following conclusions can be drawn from the test results: (1) In both nitric and sulfuric acid based reagents, the low temperature and dilute concentration environment resulted in carbon steel corrosion rates that were less than 150 mpy. These rates are manageable in that chemical cleaning processes could proceed for limited time without significant wall loss. Further optimization of the Alternative Enhance Chemical Cleaning (AECC) process should focus on testing in solutions of this dilute concentration and low temperature regime. (2) In general, for the nitric acid based reagent, the aluminum oxide phase environments resulted in higher corrosion rates than the iron oxide phase environments. (3) In general, for the sulfuric acid based reagent, the iron oxide phase environments resulted in higher corrosion rates than the aluminum oxide phase environments. (4) In general, for the nitric acid based reagent, the HM sludge simulant environments resulted in higher corrosion rates than the PUREX sludge simulant environments. This result agrees with the previous observation that the aluminum oxide phases are more aggressive than the iron oxide phase environments in the nitric acid reagent. (5) Pitting was more likely to occur in the sulfuric acid based reagents than in the nitric acid based reagents. (6) Pitting occurred only in the iron based pure oxide phases and the sludge simulants. No pitting was observed in the aluminum based pure oxide phases. (7) Pitting tended to occur more frequently in tests that involved the dilute mineral acid reagent. (8) Pitting was more severe at the higher temperature for a given mineral acid concentration. (9) Pitting was more severe at a higher mineral acid concentration for a given temperature. (10) Based on the combined results of the open circuit potential and cathodic polarization testing, there was a low propensity for hydrogen evolution in solutions where sludge has been dissolved.

08 HYDROGEN↗

DWPF COAL-CARBON WASTE ACCEPTANCE CRITERIA LIMIT EVALUATION BASED ON EXPERIMENTAL WORK (TANK 48 IMPACT STUDY)

This report summarizes the results of both experimental and modeling studies performed using Sludge Batch 10 (SB10) simulants and FBSR product from Tank 48 simulant testing in order to develop higher levels of coal-carbon that can be managed by DWPF. Once the Fluidized Bed Steam Reforming (FBSR) process starts up for treatment of Tank 48 legacy waste, the FBSR product stream will contribute higher levels of coal-carbon in the sludge batch for processing at DWPF. Coal-carbon is added into the FBSR process as a reductant and some of it will be present in the FBSR product as unreacted coal. The FBSR product will be slurried in water, transferred to Tank Farm and will be combined with sludge and washed to produce the sludge batch that DWPF will process. The FBSR product is high in both water soluble sodium carbonate and unreacted coal-carbon. Most of the sodium carbonate is removed during washing but all of the coal-carbon will remain and become part of the DWPF sludge batch. A paper study was performed earlier to assess the impact of FBSR coal-carbon on the DWPF Chemical Processing Cell (CPC) operation and melter off-gas flammability by combining it with SB10-SB13. The results of the paper study are documented in Ref. 7 and the key findings included that SB10 would be the most difficult batch to process with the FBSR coal present and up to 5,000 mg/kg of coal-carbon could be fed to the melter without exceeding the off-gas flammability safety basis limits. In the present study, a bench-scale demonstration of the DWPF CPC processing was performed using SB10 simulants spiked with varying amounts of coal, and the resulting seven CPC products were fed to the DWPF melter cold cap and off-gas dynamics models to determine the maximum coal that can be processed through the melter without exceeding the off-gas flammability safety basis limits. Based on the results of these experimental and modeling studies, the presence of coal-carbon in the sludge feed to DWPF is found to have both positive (+) and negative (-) impact as summarized below: (-) Coal-carbon is a melter reductant. If excess coal-carbon is present, the resulting melter feed may be too reducing, potentially shortening the melter life. During this study, the Reduction/Oxidation Potential (REDOX) of the melter could be controlled by varying the ratio of nitric and formic acid. (-) The addition of coal-carbon increases the amount of nitric acid added and decreases the amount of formic acid added to control melter REDOX. This means that the CPC with the FBSR product is much more oxidizing than current CPC processing. In this study, adequate formic acid was present in all experiments to reduce mercury and manganese, two of the main goals of CPC processing. (-) Coal-carbon will be oxidized to carbon dioxide or carbon monoxide in the melter. The addition of coal-carbon to the FBSR product will lead to approximately 55% higher offgas production from formate, nitrate and carbon due to the decomposition of the carbon at the maximum levels in this testing. Higher offgas production could lead to higher cold cap coverage or melter foaming which could decrease melt rate. No testing was performed to evaluate the impact of the higher melter offgas flow. (+) The hydrogen production is greatly reduced in testing with coal as less formic acid is added in CPC processing. In the high acid run without coal, the peak hydrogen generation was 15 times higher than in the high acid run with added coal-carbon. (+) Coal-carbon is a less problematic reducing agent than formic acid, since the content of both carbon and hydrogen are important in evaluating the flammability of the melter offgas. Processing with coal-carbon decreases the amount of formic acid added in the CPC, leading to a lower flammability risk in processing with coal-carbon compared to the current DWPF flowsheet. (+) The seven SB10 formulations which were tested during the bench-scale CPC demonstration were all determined to be within the off-gas flammability safety basis limits during the 9X/5X off-gas surge for normal bubbled melter operation. The concentration of coal-carbon in these baseline melter feeds varied widely from 0 to 17,863 ppm, depending on the acid addition strategy used and the extent to which the required reductant (formic acid) was replaced with coal-carbon. All baseline feeds were redox-adjusted and three of them contained TOC higher than the current theoretical TSR limit of 18,900 ppm. (-) Additional coal-carbon was then added to each baseline feed until the calculated off-gas flammability equaled the safety basis limit of 60% of the LFL at the peak of off-gas surge ('max-coal'). In doing so, however, no counterbalancing nitrate was added, thus simulating the scenario where slugs of coal enter the melter as a result of uneven distribution of coal in the slurry.

01 COAL, LIGNITE, AND PEAT↗

Proton nuclear magnetic resonance (1H NMR) of flammable organic chemicals in radioactive high–level supernatant waste at the Savannah River Site (SRS)

The Savannah River Site stores approximately 36 million gallons of radioactive and hazardous waste that contains approximately 245 million curies. The waste is sent through various chemical processes to reduce its volume and to separate various components. The facility plans to replace formic acid (a chemical used to reduce soluble mercury) with glycolic acid. Recycle solution with glycolate may flow back to the tank farm, where the glycolate can generate hydrogen gas by thermal and radiolytic mechanisms. The current analytical method for detecting glycolate (ion chromatography) in supernatant requires a large dilution to reduce interference from the nitrate anions. Hydrogen nuclear magnetic resonance is an analytical method that requires less sample dilution. It takes advantage of the CH 2 group in glycolate. Liquid samples were spiked with four different levels of glycolate to build a calibration line, as it is recommended in the standard addition method. The detection and quantitation limits determined were 1 and 5 ppm, respectively, for 32 scans, which is well below the process limit of 10 ppm. In one test, 800 scans of a supernatant spiked with 1 ppm glycolate resulted in a -CH 2 peak with a signal-to-noise ratio of 36.

1H↗

Effect of temperature and aging duration on ethylene propylene diene monomer (EPDM) nonmetallic components used in caustic liquid waste transfer lines

Nonmetallic materials are used in waste transfer lines at the United States Department of Energy’s Hanford Site Tank Farm in Benton County, Washington, USA. During use, the ethylene propylene diene monomer (EPDM) inner hose of the hose-in-hose transfer lines (HIHTLs) are exposed to β and γ radiation, caustic solutions as well as high temperatures and high pressures. Aging behavior of specimens of EPDM HIHTLs and dog-bone shaped specimens were evaluated by exposing to a solution of 25% sodium hydroxide (NaOH) at 38 °C, 54 °C and 77 °C for 6 and 12-months as well as water only at 77 °C for 12-months. Tensile strength and burst pressure of the specimens were characterized and compared with the unexposed (baseline) specimens. Both the tensile strength of the EPDM material and the burst pressure of the HIHTLs significantly decreased with the higher temperatures and longer exposure times. Analyses using scanning electron microscopy with energy dispersive X-ray spectroscopy (SEM-EDS) of the HIHTLs and the dog-bone specimens were conducted. Our results show that the surface degradation increased with increasing exposure temperature. Penetration of NaOH into the EPDM material also increased with increasing temperature and exposure duration.

36 MATERIALS SCIENCE↗

Effect of solution concentration on ethylene propylene diene monomer (EPDM) nonmetallic components used in caustic liquid waste transfer lines

The hose-in-hose transfer lines (HIHTL) used to transfer waste at the United States Department of Energy’s Hanford Site Tank Farm are fabricated from an ethylene propylene diene monomer (EPDM) synthetic rubber. During waste transport, these hoses are exposed to several stressors including caustic solutions at high temperatures and high pressures, as well as β and γ radiation. The aging behavior of HIHTL and dog-bone shaped EPDM specimens were evaluated by exposure to solutions at 77 °C containing 0.00, 6.25, 12.50, and 25.00 % (v/v) sodium hydroxide (NaOH) for 12-months. After the exposure, the material properties of the specimens were measured and compared to the unaged samples. The material properties evaluated included the tensile strength of the EPDM dog-bone samples and the burst pressure of the HIHTL. Both the tensile strength of the EPDM dog-bone samples and the burst pressure of the HIHTL specimens exposed to the 6.25 % NaOH solution exhibited the most significant deterioration and those exposed to 25.00 % NaOH solution had the least deterioration. Finally, examination of the HIHTL and the EPDM dog-bone specimens with scanning electron microscopy showed that the deterioration for the specimens exposed to 6.25 % NaOH solution were the most severe and the samples exposed to 25.00 % NaOH solution had the least deterioration.

42 ENGINEERING↗

An Application of Molecular Recognition for the Efficient Removal of Cesium from Hanford Nuclear Waste by Modular Solvent Extraction

In this work, experimental results leading to flowsheet design are presented showing how a calixarene-crown ether based solvent-extraction process can meet the challenge of cesium removal from nuclear tank wastes stored at the US Department of Energy Hanford site. Cleanup of legacy Cold War nuclear waste stored in underground tanks represents one of the greatest environmental challenges facing the US Department of Energy in terms of risk, cost, and effectiveness of applicable science and technology. Planning for the cleanup at the Hanford Site calls for the removal of the radioactive fission product 137Cs from its alkaline salt waste, including the use of modular processes that can be deployed near the tank farms. To meet the resulting need for extremely high selectivity, the Next-Generation Caustic-Side Solvent Extraction (NG-CSSX) process employing a calix[4]arene-crown ether in modified kerosene has been adapted to remove sub-millimolar cesium in competition with molar sodium and potassium in a high-nitrate alkaline matrix. Potassium loading in the solvent was determined in extraction, scrubbing, and stripping, leading to an empirical model closely approximating cesium distribution ratios for a variety of Hanford waste types. Process chemistry has been developed based on this molecular-recognition approach, focusing on the competitive effect of potassium loading and the mitigating process modifications needed, including extending the scrub section. The result is a modular flowsheet design that can achieve cesium decontamination factors well in excess of 15,000 even for the worst-case Hanford waste.

Williams, Neil [ORNL] (ORCID:000000023159226X)↗

Retrieval of Tank Waste from Storage

This book will provide an overview of the key elements in remediating complex waste sites using the Hanford Site as a case study. In this chapter, the existing infrastructure to store and transfer Hanford wastes, a short history of operations in Hanford Tank Farms, the SST retrieval needs and subsequent DST waste handling operations for retrieval, treatment, and closure are discussed. Waste retrieval operational examples are summarized.

Fountain, Matthew S.↗

Advective Desorption of Uranium (VI) from Contaminated Hanford Vadose Zone Sediments under Saturated and Unsaturated Conditions

Sedimentary, hydrologic, and geochemical variations in the Hanford subsurface environment, as well as compositional differences in contaminating waste streams, have created vast differences in the migration and mobility of uranium within the subsurface environment. A series of hydraulically-saturated and -unsaturated column experiments were performed to i.) assess the effect of water content on the advective desorption and migration of uranium from contaminated sediments, and ii.) evaluate the uranium concentration that can develop in porewater and/or groundwater as a result of desorption/dissolution reactions. Flow rate and moisture content were varied to evaluate the influence of contact time, pore water velocity, and macropore desaturation on aqueous uranium concentrations. Sediments were collected from the T-TX-TY tank farm complex and the 300 Area Process Ponds located on the Hanford Site, southeastern Washington State. The sediments vary in depth, mineralogy, and in contamination events. Experiments were conducted under mildly alkaline/calcareous conditions representative of conditions commonly encountered at repository sites across the arid western United States and, in particular, the Hanford site. Results illustrate the release of uranium from these sediments is kinetically controlled and low water contents encountered within the Hanford vadose zone result in the formation of mobile-immobile water regimes, which isolate a fraction of the reactive sites within the sediments, effectively reducing the concentration of uranium released into migrating porewaters.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Evaluating the Performance of a Surface Barrier on Reducing Soil-Water Flow

One of the most common effective techniques for contaminant remediation in the vadose zone is to use a surface barrier to reduce or eliminate soil-water flow to reduce the contaminant flux to the underlying groundwater. Confirming the reduction of the soil-water flux rate is challenging because of the difficulty of determining the very low soil-water flux beneath the barrier. We propose a hydraulic-conductivity factor, fK, as a conservative indicator for quantifying the reduction of soil-water flow. The factor can be calculated using the measured soil-water content or pressure but does not require the knowledge of the saturated hydraulic conductivity or the hydraulic gradient. The formulas were tested by comparing with changes in hydraulic conductivity, K, from a drainage experiment. The pressure-based formula was further applied to evaluate the performance of the interim surface barrier at T Tank Farm on Hanford Site. Three years after barrier emplacement, the hydraulic conductivity decreased by a factor between 3.8 and 13.0 at the 1-, 2- and 5-m depths. The difference between the conductivity-reduction factor and the flux-rate-reduction factor, fq, was quantified with a numerical simulation. With the calculated fK, the numerically determined fK/fq ratio, and the assumed pre-barrier soil-water flux rate of 100 mm yr-1, the estimated soil-water flux rate 3 years after barrier emplacement was no more than 8.5 mm yr-1 at or above the 5-m depth.

efficiency↗