Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “TRACKING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

First results of the silicon telescope using an 'artificial retina' for fast track finding

We present the first results of the prototype of a silicon tracker with trigger capabilities based on a novel approach for fast track finding. The working principle of the 'artificial retina' is inspired by the processing of visual images by the brain and it is based on extensive parallelization of data distribution and pattern recognition. The algorithm has been implemented in commercial FPGAs in three main logic modules: a switch for the routing of the detector hits, a pool of engines for the digital processing of the hits, and a block for the calculation of the track parameters. The architecture is fully pipelined and allows the reconstruction of real-time tracks with a latency less then 100 clock cycles, corresponding to 0.25 microsecond at 400 MHz clock. The silicon telescope consists of 8 layers of single-sided silicon strip detectors with 512 strips each. The detector size is about 10 cm x 10 cm and the strip pitch is 183 μm. The detectors are read out by the Beetle chip, a custom ASICs developed for LHCb, which provides the measurement of the hit position and pulse height of 128 channels. The 'artificial retina' algorithm has been implemented on custom data acquisition boards based on FPGAs Xilinx Kintex 7 lx160. The parameters of the tracks detected are finally transferred to host PC via USB 3.0. The boards manage the read-out ASICs and the sampling of the analog channels. The read-out is performed at 40 MHz on 4 channels for each ASIC that corresponds to a decoding of the telescope information at 1.1 MHz. We report on the first results of the fast tracking device and compare with simulations. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Model and Validation of Single-Axis Tracking with Bifacial PV

Single-axis tracking is a cost-effective deployment strategy for large-scale ground-mount photovoltaic systems in regions with high direct-normal irradiance. Bifacial modules in 1-axis-tracking systems boost energy yield by 4%-15% depending on module type and ground albedo, with a global average of 9%. This benefit is in addition to the 15%-25% energy gain already afforded by single-axis tracking relative to fixed-tilt deployments. Here, we compare model results against field performance data for two side-by-side bifacial/monofacial tracked systems - one in Albuquerque, NM, USA, and one in eastern Oregon. The Albuquerque system shows monthly rear irradiance gain of 10%-14.9%, and the Oregon bifacial system has an average performance ratio 9.4% higher than the monofacial system. Both results match bifacial irradiance model results within uncertainty. Simulations show that smart tracking algorithms can offer more than 1% improvement on annual energy yield by adjusting tilt angle under cloudy conditions. Finally, ray-tracing simulations investigated edge brightening, suggesting a 15%-25% increase in rear irradiance at the ends of tracker rows, but up to 20% loss from center-mounted torque tubes, creating multiple shadows.

14 SOLAR ENERGY↗

Vehicle track segmentation using higher order random fields

Here, we present an approach to segment vehicle tracks in coherent change detection images, a product of combining two synthetic aperture radar images taken at different times. The approach uses multiscale higher order random field models to capture track statistics, such as curvatures and their parallel nature, that are not currently utilized in existing methods. These statistics are encoded as 3-by-3 patterns at different scales. The model can complete disconnected tracks often caused by sensor noise and various environmental effects. Coupling the model with a simple classifier, our approach is effective at segmenting salient tracks. We improve the F-measure on a standard vehicle track data set to 0.963, up from 0.897 obtained by the current state-of-the-art method.

97 MATHEMATICS AND COMPUTING↗

SU-E-J-156: Preclinical Inverstigation of Dynamic Tumor Tracking Using Vero SBRT Linear Accelerator: Motion Phantom Dosimetry Study

Purpose: Following the ‘end-to-end testing’ paradigm of Dynamic Target Tracking option in our Image-Guided dedicated SBRT VeroTM linac, we verify the capability of the system to deliver planned dose to moving targets in the heterogeneous thorax phantom (CIRSTM). The system includes gimbaled C-band linac head, robotic 6 degree of freedom couch and a tumor tracking method based on predictive modeling of target position using fluoroscopically tracked implanted markers and optically tracked infrared reflecting external markers. Methods: 4DCT scan of the motion phantom with the VisicoilTM implanted marker in the close vicinity of the target was acquired, the ‘exhale’=most prevalent phase was used for planning (iPlan by BrainLabTM). Typical 3D conformal SBRT treatment plans aimed to deliver 6-8Gy/fx to two types of targets: a)solid water-equivalent target 3cm in diameter; b)single VisicoilTM marker inserted within lung equivalent material. The planning GTV/CTV-to-PTV margins were 2mm, the block margins were 3 mm. The dose calculated by MonteCarlo algorithm with 1% variance using option Dose-to-water was compared to the ion chamber (CC01 by IBA Dosimetry) measurements in case (a) and GafchromicTM EBT3 film measurements in case (b). During delivery, the target 6 motion patterns available as a standard on CIRSTM motion phantom were investigated: in case (a), the target was moving along the designated sine or cosine4 3D trajectory; in case (b), the inserted marker was moving sinusoidally in 1D. Results: The ion chamber measurements have shown the agreement with the planned dose within 1% under all the studied motion conditions. The film measurements show 98.1% agreement with the planar calculated dose (gamma criteria: 3%/3mm). Conclusion: We successfully verified the capability of the SBRT VeroTM linac to perform real-time tumor tracking and accurate dose delivery to the target, based on predictive modeling of the correlation between implanted marker motion and external surrogate of breathing motion.

60 APPLIED LIFE SCIENCES↗

SU-D-210-05: The Accuracy of Raw and B-Mode Image Data for Ultrasound Speckle Tracking in Radiation Therapy

Purpose: For ultrasound speckle tracking there is some evidence that the envelope-detected signal (the main step in B-mode image formation) may be more accurate than raw ultrasound data for tracking larger inter-frame tissue motion. This study investigates the accuracy of raw radio-frequency (RF) versus non-logarithmic compressed envelope-detected (B-mode) data for ultrasound speckle tracking in the context of image-guided radiation therapy. Methods: Transperineal ultrasound RF data was acquired (with a 7.5 MHz linear transducer operating at a 12 Hz frame rate) from a speckle phantom moving with realistic intra-fraction prostate motion derived from a commercial tracking system. A normalised cross-correlation template matching algorithm was used to track speckle motion at the focus using (i) the RF signal and (ii) the B-mode signal. A range of imaging rates (0.5 to 12 Hz) were simulated by decimating the imaging sequences, therefore simulating larger to smaller inter-frame displacements. Motion estimation accuracy was quantified by comparison with known phantom motion. Results: The differences between RF and B-mode motion estimation accuracy (2D mean and 95% errors relative to ground truth displacements) were less than 0.01 mm for stable and persistent motion types and 0.2 mm for transient motion for imaging rates of 0.5 to 12 Hz. The mean correlation for all motion types and imaging rates was 0.851 and 0.845 for RF and B-mode data, respectively. Data type is expected to have most impact on axial (Superior-Inferior) motion estimation. Axial differences were <0.004 mm for stable and persistent motion and <0.3 mm for transient motion (axial mean errors were lowest for B-mode in all cases). Conclusions: Using the RF or B-mode signal for speckle motion estimation is comparable for translational prostate motion. B-mode image formation may involve other signal-processing steps which also influence motion estimation accuracy. A similar study for respiratory-induced motion would also be prudent. This work is support by Cancer Research UK Programme Grant C33589/A19727.

60 APPLIED LIFE SCIENCES↗

SU-F-BRA-03: Integrating Novel Electromagnetic Tracking Hollow Needle Assistance in Permanent Implant Brachytherapy Procedures

Purpose: To report on the results of a complete permanent implant brachytherapy procedure assisted by an electromagnetic (EM) hollow needle possessing both 3D tracking and seed drop detection abilities. Methods: End-to-end in-phantom EM-assisted LDR procedures were conducted. The novel system consisted of an EM tracking apparatus (NDI Aurora V2, Planar Field Generator), a 3D US scanner (Philips CX50), a hollow needle prototype allowing 3D tracking and seed drop detection and a specially designed treatment planning software (Philips Healthcare). A tungsten-doped 30 cc spherical agarose prostate immersed in gelatin was used for the treatment. A cylindrical shape of 0.8 cc was carved along its diameter to mimic the urethra. An initial plan of 26 needles and 47 seeds was established with the system. The plan was delivered with the EM-tracked hollow needle, and individual seed drop locations were recorded on the fly. The phantom was subsequently imaged with a CT scanner from which seed positions and contour definitions were obtained. The DVHs were then independently recomputed and compared with those produced by the planning system, both before and after the treatment. Results: Of the 47 seeds, 45 (96%) were detected by the EM technology embedded in the hollow needle design. The executed plan (from CT analysis) differed from the initial plan by 2%, 14% and 8% respectively in terms of V100, D90 and V150 for the prostate, and by 8%, 7% and 10% respectively in terms of D5, V100 and V120 for the urethra. Conclusion: The average DVH deviations between initial and executed plans were within a 5% tolerance imposed for this proof-of-concept assessment. This relatively good concordance demonstrates the feasibility and potential benefits of combining EM tracking and seed drop detection for real-time dosimetry validation and assistance in permanent implant brachytherapy procedures. This project has been entirely funded by Philips Healthcare.

60 APPLIED LIFE SCIENCES↗

DoE Phase II SBIR: Spectrally-Assisted Vehicle Tracking

The goal of this Phase II SBIR is to develop a prototype software package to demonstrate spectrally-aided vehicle tracking performance. The primary application is to demonstrate improved target vehicle tracking performance in complex environments where traditional spatial tracker systems may show reduced performance. Example scenarios in Figure 1 include a) the target vehicle obscured by a large structure for an extended period of time, or b), the target engaging in extreme maneuvers amongst other civilian vehicles. The target information derived from spatial processing is unable to differentiate between the green versus the red vehicle. Spectral signature exploitation enables comparison of new candidate targets with existing track signatures. The ambiguity in this confusing scenario is resolved by folding spectral analysis results into each target nomination and association processes. Figure 3 shows a number of example spectral signatures from a variety of natural and man-made materials. The work performed over the two-year effort was divided into three general areas: algorithm refinement, software prototype development, and prototype performance demonstration. The tasks performed under this Phase II to accomplish the program goals were as follows: 1. Acquire relevant vehicle target datasets to support prototype. 2. Refine algorithms for target spectral feature exploitation. 3. Implement a prototype multi-hypothesis target tracking software package. 4. Demonstrate and quantify tracking performance using relevant data.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Eye-Tracking Analysis from a Flight-Director-Use and Pilot-Monitoring Study

Eye tracking may be a useful tool to investigate pilot monitoring and develop and conduct training. There is increased interest from airlines to use eye-tracking technologies in flight simulators. However, much is still unknown about how to best utilize eye-tracking data in pilot training. This paper presents eye-tracking results from a pilot-monitoring training study with 19 pilots. All pilots completed 15 monitoring challenges across four operational scenarios in a B737-700 full flight simulator. In addition, the study investigated the impact of having the flight director engaged or disengaged on the pilot monitoring side in the final approach. It was hypothesized that pilots would focus less on the primary flight display with the flight director off and look more around in the cockpit. To assess this, pilots performed half of the scenarios with the flight director on and half with the flight director off. However, pilots monitoring tended to look less at the primary flight display with the flight director on as indicated by lower Proportion Dwell Times, contrary to the hypothesis. Next, eye-tracking data were analyzed from two monitoring challenges involving waypoint restrictions and two involving extending the flaps at appropriate airspeeds. Pilots that successfully completed the challenges appeared to focus more on areas of interest that contained the most relevant information to successfully complete the challenge. In addition, successful pilots seemed to adapt their monitoring strategy more to the challenge at hand as observed by a distinct shift in focus on either the primary flight display or the navigation display depending on the challenge. Our findings suggest the importance of flexible gaze allocation across specific situations and raise the question whether and to what degree prespecified patterns of eye fixation can be identified and trained.

eye tracking↗

Eye-Tracking Analysis from a Flight-Director-Use and Pilot-Monitoring Study

Eye tracking may be a useful tool to investigate pilot monitoring and develop and conduct training. There is increased interest from airlines to use eye-tracking technologies in flight simulators. However, much is still unknown about how to best utilize eye-tracking data in pilot training. This paper presents eye-tracking results from a pilot-monitoring training study with 19 pilots. All pilots completed 15 monitoring challenges across four operational scenarios in a B737-700 full flight simulator. In addition, the study investigated the impact of having the flight director engaged or disengaged on the pilot monitoring side in the final approach. It was hypothesized that pilots would focus less on the primary flight display with the flight director off and look more around in the cockpit. To assess this, pilots performed half of the scenarios with the flight director on and half with the flight director off. However, pilots monitoring tended to look less at the primary flight display with the flight director on as indicated by lower Proportion Dwell Times, contrary to the hypothesis. Next, eye-tracking data were analyzed from two monitoring challenges involving waypoint restrictions and two involving extending the flaps at appropriate airspeeds. Pilots that successfully completed the challenges appeared to focus more on areas of interest that contained the most relevant information to successfully complete the challenge. In addition, successful pilots seemed to adapt their monitoring strategy more to the challenge at hand as observed by a distinct shift in focus on either the primary flight display or the navigation display depending on the challenge. Our findings suggest the importance of flexible gaze allocation across specific situations and raise the question whether and to what degree prespecified patterns of eye fixation can be identified and trained.

eye tracking↗

Characterization of Infrared Optical Motion Tracking System in NASA's Simulated Lunar Operations (SLOPE) Laboratory

This work characterizes the accuracy of a 16 camera OptiTrack motion tracking system installed in NASA Glenn Research Center's Simulated Lunar Operations (SLOPE) laboratory. The position of a rigid body mounted on a motorized linear stage is compared to its position reported by the motion tracking system as it travels through the facility's 777m$^3$ capture volume of interest. Experiments show that the mean error reported by the motion tracking system for the aggregate capture volume is in-line with independent measurements collected using the motion stage. Error within regions of the capture volume exceed the mean error reported by the motion tracking system, likely due to occlusion, and suggests that additional cameras should be used to increase measurement accuracy in these regions. Overall, results show that error values reported by the motion tracking system are representative of the measurement error in a collected data set and validates the system's use for characterizing the mobility and tractive performance of robots, rovers, and other vehicles for planetary exploration.

Motion capture↗

Global Reduction in Ship-tracks from Sulfur Regulations for Shipping Fuel

Ship-tracks are produced by ship-emitted aerosols interacting with low clouds. Here, we apply deep learning models on satellite data to produce the first global climatology map of ship-tracks. We show that ship-tracks are at the nexus of cloud physics, maritime shipping, and fuel regulation. Our map captures major shipping lanes while missing others because of background conditions. Ship-track frequency is more than 10 times higher than a previous survey, and its interannual fluctuations reflect variations in cross-ocean trade, shipping activity, and fuel regulations. Fuel regulation can alter both detected frequency and shipping routes due to cost. The 2020 fuel regulation, together with the coronavirus disease 2019 pandemic, reduced ship-track frequency to its lowest level in recent decades across the globe and may have ushered in an era of low frequency. The regulation reduces the aerosol indirect forcing from ship emissions by 46% or between 0.02 and 0.27 W m −2 given its current estimates.

ship tracks↗

Satellite Tracking of Shallow Cumulus during CAMP2Ex: The Aerosol and Organization Connection

Shallow moist convection is ubiquitous throughout the tropics and represents a key player in boundary layer processes. Shallow clouds come in many forms, from scattered, short-lived cumulus to organized features that include cold pool boundaries and lines reaching O(100 km) scale lasting several hours. In this study, we explore how cloud morphology and environmental aerosol affect shallow cumulus lifecycle properties. Measuring such influences requires a broad, detailed view of these cloud fields as they grow and decay. Geostationary satellites provide a means to follow the clouds with enhanced spatiotemporal sampling from space. We apply a cloud-tracking tool to study lifecycle properties of shallow cumulus sampled during the NASA Cloud, Aerosol, and Monsoon Processes Philippines Experiment (CAMP2Ex) field campaign of 2019. The mission conducted airborne and shipborne operations over the West Pacific Ocean, in tandem with Rapid Scan imagery from the Advanced Himawari Imager (AHI) on the Japan Meteorological Agency’s (JMA) Himawari-8 satellite. We segment shallow cumulus on AHI 0.5-km visible reflectance during the daylit hours of several research flights that exhibited ideal atmospheric conditions for tracking. We collect the resulting cloud tracks by regions containing airborne sampling of the cloud environments and by two specific segmentation techniques: one optimized for small, disorganized cumulus and the other for larger, organized clouds using suitable thresholds for reflectance and blurring. We present an analysis of cloud lifecycle properties using our dual segmentation approach for various sampled environments of CAMP2Ex. A total of 7 research flights (RFs) exhibited ideal conditions for generating cloud-track ensembles under similar thermodynamic and kinematic profiles but with varying aerosol load. We consider lifetime, track-achieved metrics, and ensemble-fitted growth rates to evaluate the aerosol effect. Cloud elongation, a factor in cloud morphology, is also considered for any potential influence in observed shifts in growth rates. The results suggest that aerosol affects cloud lifecycles more significantly for clouds with larger areas and independent of the elongation factor.

Cloud Tracking↗

Model and Validation of Single-Axis Tracking with Bifacial Photovoltaics: Preprint

Single-axis tracking is a cost effective deployment strategy for large-scale ground-mount photovoltaic (PV) systems in regions with high direct-normal irradiance (DNI). Bifacial modules in 1-axis tracking systems boost energy yield by 4% - 15% depending on module type and ground albedo, with a global average of 9%. This benefit is in addition to the 15%-25% energy gain already afforded by single-axis tracking relative to fixed-tilt deployments. Here we compare model results against field performance data for two side-by-side bifacial / monofacial tracked systems - one in Albuquerque NM, and one in eastern Oregon. The Albuquerque system shows monthly rear irradiance gain of 10-14.9%, and the Oregon bifacial system has an average performance ratio 9.4% higher than the monofacial system. Both results match bifacial irradiance model results within uncertainty. Simulations show that smart tracking algorithms can offer more than 1% improvement on annual energy yield by adjusting tilt angle under cloudy conditions. Finally, ray-tracing simulations investigated edge brightening, suggesting 15%-25% increase in rear irradiance at the ends of tracker rows, but up to 20% loss from center-mounted torque tubes, creating multiple shadows.

14 SOLAR ENERGY↗

Atmospheric {sup 41}Ar Plume Tracking of the UF Training Reactor Using a Large-Volume NaI Detector

The ability to track and monitor gaseous radioactive materials is important in the event of a radioactive release such as from a nuclear power plant accident, weapons testing, or other unintended release scenarios. The International Monitoring System (IMS) is currently in place to monitor for weapons testing and has been used to monitor nuclear power plant accidents. However, only 80 radionuclide stations for the IMS exist in the world and are stationary, limiting the resolution of any radioactive plumes detected. Furthermore, the IMS radionuclide stations are designed to be sensitive specifically to atmospheric radio-xenon and no other radionuclides. Historically, monitoring radioactive releases has been limited to the detection of radio-xenon and radio-krypton, both arising as fission products from nuclear fuel. After the accident at Three Mile Island Unit 2, scientists were interested in finding the dose the public received from released radioactive material. This was achieved by analyzing radiation monitors in the exhaust stack and filters within the reactor building. furthermore, a series of 20 thermoluminescent dosimeters (TLD's), 8 air sampling station positioned around Three Mile Island, and a helicopter survey which used a NaI(Tl) detector array provided data on radionuclides, specifically {sup 137}Cs, that escaped the confines of the reactor building. The TLD's and air sampling stations were stationary, and therefore limited the resolution of the radioactive release plume. The helicopter survey using the NaI detectors was limited by the technology available at the time. The NaI detector array output was compressed from 1024 channels to 256 channels, limiting the energy resolution of the spectral data. The helicopter used a microwave ranging system to establish position. Since this survey was taken in October of 1982, advancements in technology allow spectral data to be saved in its full 1024 channel format and the advent of GPS can give a more accurate account of the detector position. An updated mobile system for tracking a radioactive release would help to alleviate these issues as well as gain the ability to track a radioactive release in real-time. We investigate the feasibility of mobile tracking through study and measurement of the {sup 41}Ar plume released from the University of Florida Training Reactor (UFTR) research reactor. We use a large-volume NaI(Tl) detector placed on the roof near the reactor. This detector may also be placed and moved on a cart to survey the area surrounding the reactor. We compare the spectral data taken when the reactor is running at full power to the background to analyze the effectiveness of the detector at identifying atmospheric {sup 41}Ar. Finally we discuss the implications of these measurements with regards to validation of plume models and the capability to track releases over a localized area from the source. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Chapter 6: CPV Tracking and Trackers

This chapter explains the functional requirements of a concentrator photovoltaic (CPV) sun tracker. It derives the design specifications of a CPV tracker. The chapter presents taxonomy of trackers describing the most common tracking architectures, based on the number of axes, their relative position, and the foundation and placing of tracking drives. It deals with the structural issues related to tracker design, mainly related to structural flexure and its impact on the system's acceptance angle. The chapter analyzes the auto-calibrated sun tracking control, by describing the state of the art and its development background. It explores the sun tracking accuracy measurement with a practical example. The chapter discusses tracker manufacturing and tracker field works. It reviews survey of different types of tracker designs obtained from different manufacturers. Finally, the chapter deals with IEC62817, the technical standard developed for CPV sun trackers.

14 SOLAR ENERGY↗

Optimizing trigger-level track reconstruction for sensitivity to exotic signatures

Many compelling beyond the Standard Model scenarios predict signals that result in unconventional charged particle trajectories. Signatures for which unusual tracks are the most conspicuous feature of the event pose significant challenges for experiments at the Large Hadron Collider (LHC), particularly for the trigger. This article presents a study of track-based triggers for a representative set of long-lived and unconventional signatures at the upcoming High Luminosity LHC, as well as resulting recommendations for the target parameters of a hardware-based tracking system. Scenarios studied include large multiplicities of low-p T tracks produced in a soft-unclustered-energy-pattern model, displaced leptons and anomalous prompt tracks predicted in a Supersymmetry model with long-lived staus, and displaced hadrons predicted in a Higgs portal scenario with long-lived scalars.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Megavoltage Image-Based Dynamic Multileaf Collimator Tracking of a NiTi Stent in Porcine Lungs on a Linear Accelerator

Purpose: To investigate the accuracy and potential limitations of MV image-based dynamic multileaf collimator (DMLC) tracking in a porcine model on a linear accelerator. Methods and Materials: A thermo-expandable NiTi stent designed for kilovoltage (kV) X-ray visualization of lung lesions was inserted into the bronchia of three anaesthetized Goettingen minipigs. A four-dimensional computed tomography scan was used for planning a five-field conformal treatment with circular multileaf collimator (MLC) apertures. A 22.5 Gy single fraction treatment was delivered to the pigs. The peak-to-peak stent motion was 3 to 8 mm, with breathing periods of 1.2 to 4 s. Before treatment, X-ray images were used for image-guided setup based on the stent. During treatment delivery, continuous megavoltage (MV) portal images were acquired at 7.5 Hz. The stent was segmented in the images and used for continuous adaptation of the MLC aperture. Offline, the tracking error in beam's eye view of the treatment beam was calculated for each MV image as the difference between the MLC aperture center and the segmented stent position. The standard deviations of the systematic error {Sigma} and the random error {sigma} were determined and compared with the would-be errors for a nontracking treatment with pretreatment image-guided setup. Results: Reliable stent segmentation was obtained for 11 of 15 fields. Segmentation failures occurred when image contrast was dominated by overlapping anatomical structures (ribs, diaphragm) rather than by the stent, which was designed for kV rather than MV X-ray visibility. For the 11 fields with reliable segmentation, {Sigma} was 0.5 mm/0.4 mm in the two imager directions, whereas {sigma} was 0.5 mm/1.1 mm. Without tracking, {Sigma} and {sigma} would have been 1.7 mm/1.4 mm and 0.8 mm/1.4 mm, respectively. Conclusion: For the first time, in vivo DMLC tracking has been demonstrated on a linear accelerator showing the potential for improved targeting accuracy. The study mimicked the envisioned patient workflow of future patient treatments. Clinical implementation of MV image-based tracking would require markers designed for MV visibility.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Verification of Accuracy of CyberKnife Tumor-tracking Radiation Therapy Using Patient-specific Lung Phantoms

Purpose: To investigate the accuracy of the CyberKnife Xsight Lung Tracking System (XLTS) compared with that of a fiducial-based target tracking system (FTTS) using patient-specific lung phantoms. Methods and Materials: Three-dimensional printing technology was used to make individualized lung phantoms that closely mimicked the lung anatomy of actual patients. Based on planning computed tomographic data from 6 lung cancer patients who underwent stereotactic ablative radiation therapy using the CyberKnife, the volume above a certain Hounsfield unit (HU) was assigned as the structure to be filled uniformly with polylactic acid material by a 3-dimensional printer (3D Edison, Lokit, Korea). We evaluated the discrepancies between the measured and modeled target positions, representing the total tracking error, using 3 log files that were generated during each treatment for both the FTTS and the XLTS. We also analyzed the γ index between the film dose measured under the FTTS and XLTS. Results: The overall mean values and standard deviations of total tracking errors for the FTTS were 0.36 ± 0.39 mm, 0.15 ± 0.64 mm, and 0.15 ± 0.62 mm for the craniocaudal (CC), left–right (LR), and anteroposterior (AP) components, respectively. Those for the XLTS were 0.38 ± 0.54 mm, 0.13 ± 0.18 mm, and 0.14 ± 0.37 mm for the CC, LR, and AP components, respectively. The average of γ passing rates was 100% for the criteria of 3%, 3 mm; 99.6% for the criteria of 2%, 2 mm; and 86.8% for the criteria of 1%, 1 mm. Conclusions: The XLTS has segmentation accuracy comparable with that of the FTTS and small total tracking errors.

62 RADIOLOGY AND NUCLEAR MEDICINE↗