Relative toxicity of pyrolysis products of some polyurethane and polychloroprene foams

Results of toxicity screening tests on some polyurethane and polychloroprene flexible foams are presented. The test method involves the exposure of four Swiss albino male mice in a 4.2-liter hemispherical chamber to the pyrolysis effluents from 1 g of sample exposed to temperatures rising from 200 to 800 C at a rate of 40 C/min. Mortality and times to incapacitation and to death are recorded. Comparisons indicate that flexible polyurethane foams without fire retardant are more toxic than the corresponding foams containing fire retardant, and polychloroprene foams are least toxic.

Hilado, C. J.↗

Relative toxicity of pyrolysis products of some elastomers

Ten samples comprising seven generic types of elastomers were evaluated for relative toxicity using the USF/NASA toxicity screening test method. The nitrile rubber samples appeared to generally exhibit greater toxicity than the samples of polyisoprene, styrene butadiene, and chlorinated polyethylene rubber. Carbon monoxide was present in sufficient concentration in the blood of the test animals to be the principal cause of death in the case of polyisoprene and styrene butadiene rubber.

Hilado, C. J.↗

Toxicity studies of a polyurethane rigid foam

Relative toxicity tests were performed on a polyurethane foam containing a trimethylopropane-based polyol and an organophosphate flame retardant. The routine screening procedure involved the exposure of four Swiss albino male mice in a 4.2 liter hemispherical chamber to the products generated by pyrolyzing a 1.00 g sample at a heating rate of 40 deg C/min from 200 to 800 C in the absence of air flow. In addition to the routine screening, experiments were performed with a very rapid rise to 800 C, with nominal 16 and 48 ml/sec air flow and with varying sample rates. No unusual toxicity was observed with either gradual or rapid pyrolysis to 800 C. Convulsions and seizures similar to those previously reported were observed when the materials were essentially flash pyrolyzed at 800 C in the presence of air flow, and the toxicity appeared unusual because of low sample weights required to produce death.

Hilado, C. J.↗

Hydrocarbon concentrations in fire toxicity tests as an indication of flash fire propensity

The concentrations of hydrocarbons in the gases from fire toxicity tests are often determined to obtain an indication of their contribution to toxic effects and of the mechanisms of thermal decomposition. Because the gas compositions produced in the University of San Francisco/NASA toxicity screening test are generated under identical pyrolysis conditions, they offer the potential of comparing the flash-fire propensity of various materials.

Hilado, C. J.↗

The possibility of flash fires in toxicity tests

The concentrations of combustible compounds in the gases generated in toxicity tests may together result in a flammable mixture which could be ignited by accident or by a deficiency in procedure. The principal hazard stems from the increase in the concentrations of combustible non-toxic gases which may result from efforts to increase the concentrations of toxic gases to obtain desired physiological responses.

Hilado, C. J.↗

Relative toxicity of pyrolysis products of some building materials

Fourteen samples of building materials were evaluated for relative toxicity using the USF/NASA toxicity screening test method. There appeared to be no major differences in relative toxicity under these conditions between different samples of cellulosic board products and roofing felts.

Hilado, C. J.↗

Effect of test conditions on relative toxicity rankings of fifteen materials

Fifteen materials were evaluated for relative toxicity of pyrolysis effluents, using different test conditions in the USF methodology. Wool fabrics were consistently among the most toxic materials, and polystyrene and polychloroprene flexible foam were consistently among the least toxic materials.

Hilado, C. J.↗

Toxicity of pyrolysis gases from some cellular polymers

Various samples of cellular polymers were evaluated for toxicity of pyrolysis gases, using the screening test method developed at the University of San Francisco. The cellular polymer samples included polyimide, polymethacrylimide, polybismaleimide, polyurethane, polyisocyanurate, polyethylene, polychloroprene, polyvinyl chloride, polystyrene, polysiloxane, and polyphosphazene. The cellular polymers exhibited varying levels of toxicity under these test conditions. Among the rigid cellular polymers, times to death were shortest with the imide type foams and longest with polyvinyl chloride and polystyrene. Among the flexible cellular polymers, times to death were shortest with polyimide and polyester, and longest with polychloroprene and polysiloxane. Increased char yield was not necessarily associated with reduced toxicity.

Hilado, C. J.↗

A comparative study of the toxicity of the combustion products of Tedlar and a fluorenone-polyester film

The relative toxicity in rats resulting from a 30 minute exposure to the combustion products of two materials, Tedlar and fluorenone-polyester film was assessed. The combustion products were generated into a static exposure system using a laboratory-scale furnace. The toxicity was assessed using the primary measurements employed in a more detailed overall toxicity evaluation. The toxicological events observed during the 30 minute exposure are reported.

Farrar, D. G.↗

Effect of pyrolysis temperature and air flow on toxicity of gases from a polycarbonate polymer

A polycarbonate polymer was evaluated for toxicity of pyrolysis gases generated at various temperatures without forced air flow and with 1 L/min air flow, using the toxicity screening test method developed at the University of San Francisco. Time to various animal responses decreased with increasing pyrolysis temperature over the range from 500 C to 800 C. There appeared to be no significant toxic effects at 400 C and lower temperatures.

Hilado, C. J.↗

Toxicity of pyrolysis gases from polyoxymethylene

A sample of polyoxymethylene was evaluated for toxicity of pyrolysis gases, using the toxicity screening test method developed at the University of San Francisco. Under several test conditions, this material gave shorter times to death than many other synthetic polymers. Carbon monoxide appeared to be the principal toxicant in the pyrolysis gases.

Hilado, C. J.↗

Toxicity of pyrolysis gases from polytetrafluoroethylene

A sample of polytetrafluoroethylene was evaluated for toxicity of pyrolysis gases, using various test conditions of the toxicity screening test method developed at the University of San Francisco. Time to death appears to be affected by the material of which the pyrolysis tube is made, with Monel tending to give longer times to death than quartz. When quartz tubes are used, time to death seems to be related to carbon monoxide concentration. When Monel tubes are used, carbon monoxide does not appear to be the principal toxicant.

Hilado, C. J.↗

Toxicity of pyrolysis gases from polyether sulfone

A sample of polyether sulfone was evaluated for toxicity of pyrolysis gases, using the toxicity screening test method developed at the University of San Francisco. Animal response times were relatively short at pyrolysis temperatures of 600 to 800 C, with death occurring within 6 min. The principal toxicant appeared to be a compound other than carbon monoxide.

Hilado, C. J.↗

Relative toxicity of materials in fire situations

The results of toxicity testing of additional materials is presented. Relative toxicity data on polymers by generic type are presented and include wood, polyurethane flexible foam, polyvinyl chloride (PVC), acrylonitrile/butadiene/styrene (ABS), and polyisoprene (natural rubber). A second table gives relative toxicity data on fibers and fabrics including wool, nylon, rayon, polyester, and aromatic polyamide. Sulfur-containing materials seemed to exhibit the shortest times to death of laboratory animals. Some chlorine-containing polymers tended to exhibit shortest time to death also while some halogen-containing polymers gave the shortest time to incapacitation. Among fibers and fabrics, wool, silk, and polyester exhibited the shortest times to incapacitation and times to death. Difficulty in restricting generally accepted materials is discussed and attention is given to other factors important in comparing materials, such as backcoatings and relative weights.

Hilado, C. J.↗

Toxicity of pyrolysis gases from foam plastics

Twenty-three samples of flexible foams and twelve samples of rigid foams were evaluated for toxicity of pyrolysis gases, using the USF toxicity screening test method. Polychloroprene among the flexible foams, and polystyrene among the rigid foams, appeared to exhibit the least toxicity under these particular test conditions.

Hilado, C. J.↗

Toxic-Waste Disposal by Combustion in Containers

Chemical wastes burned with minimal handling in storage containers. Technique for disposing of chemical munitions by burning them inside shells applies to disposal of toxic materials stored in drums. Fast, economical procedure overcomes heat-transfer limitations of conventional furnace designs by providing direct contact of oxygenrich combustion gases with toxic agent. No need to handle waste material, and container also decontaminated in process. Oxygen-rich torch flame cuts burster well and causes vaporization and combustion of toxic agent contained in shell.

Houseman, J.↗

Toxic substances registry system: Index of material safety data sheets

The Jul. 1992 Revision of the KSC Toxic Substances Registry System (TSRS) Index of Material Safety Data Sheets (MSDS's) is presented. The listed MSDS's reflect product inventories and associated MSDS's which were submitted to the Toxic Substance Registry Data Base maintained by the Base Operations Contractors of the Biomedical Operations and Research Office of KSC. The purpose of the index is to provide a means of accessing information on the hazards associated with the toxic and otherwise hazardous chemicals stored and used at KSC. Indices are provided for manufacturers, trademarks, and stock numbers.

Source record↗

Toxic substances registry system: Index of material safety data sheets

The Oct. 1992 Revision of the KSC Toxic Substances Registry System (TSRS) Index of Material Safety Data Sheets (MSDS's) is presented. The listed MSDS's reflect product inventories and associated MSDS's which were submitted to the Toxic Substance Registry Data Base maintained by the Base Operations Contractors of the Biomedical Operations and Research Office of KSC. The purpose of the index is to provide a means of accessing information on the hazards associated with the toxic and otherwise hazardous chemicals stored and used at KSC. Indices are provided for manufacturers, trademarks, and stock numbers.

Source record↗