Magnetic head/tape interface study for satellite tape recorders. Volume 3: Test methods and procedures
Test methods and procedures for determining effect of chemical and physical forces at magnetic head/tape interface of satellite tape recorders
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Test methods and procedures for determining effect of chemical and physical forces at magnetic head/tape interface of satellite tape recorders
Chemical and physical forces at magnetic head/tape interface of satellite tape recorders
IBM 360 TELOR3 program for testing, editing, and listing information on ORB3A tape
Preformed, low cost, thin film thermocouples on adhesive tapes were fabricated. Metal strips of two dissimilar metals were laid on opposite edges of plastic substrate so that they overlap in center portion, forming thermocouple junction. Useful temperature range for polyimide films was 4 to 673 K.
Skew test data are presented on a tape recorder transport with a double capstan drive for a 100 KHz tone recorded on five tracks simultaneously. Phase detectors were used to measure the skew when the center channel was the 100 KHz reference.
The feasibility of a tape transport chemiluminescence system for bacterial monitoring of regenerated water was demonstrated using a manually operated laboratory breadboard. The principle of detection is based on measuring the increase in chemiluminescence produced by the catalytic action of bacterial porphyrins on a luminol-hydrogen peroxide mixture. Viable organisms are distinguished from nonviable by comparing the signals of incubated and unincubated water samples. Using optimized protocols, sensitivities were obtained with 400 ml suspensions of E. coli and Cl. sporogenes. The sensitivity of the unincubated cycle E. coli (aerobe) was found to be 30 to 35 cells/m1, and that of the Cl. sporogenes (anaerobe) was 1000 to 10,000 cells/m1. The lower sensitivity toward Cl. sporogenes is attributed to several factors, namely the lower cytochrome content, the tendency to sporulate, long lag periods and the lower growth rate of Clostridia in general. The operational procedures used for processing the incubated and unincubated samples involved the following sequence: (1) concentrating the sample by filtration through a membrane filter, (2) washing with Dextrose-Thioglycollate Broth (3) incubating (0 to 4 hrs as required), (4) washing with 4M Urea, and (5) reacting with reagent in front of a photomultiplier tube. The signal output was recorded on a strip chart recorder.
An input unit designed for the BESM-3M general-purpose digital computer is described. The input unit uses a standard MEZ-28A studio tape recorder. An automatic data-input subroutine is presented.
A spacecraft recorder was developed with the objective of functioning continuously for 5 years. The resulting design employed a metallic tape wound in a 200-turn helix. A direct drive, brushless dc torquer and servo speed control drove the recorder at 3 rpm for recording and 54 rpm for playback.
A peripheral drive belt on the Mariner Mars 1971 tape recorder failed when a thin longitudinal strip separated off one edge. Analysis showed that the most probable cause of failure occurred from flexural fatigue initiating in mechanically weak locations which are introduced into the belt during fabrication. Methyl ethyl ketone, which is employed as a cleaning solvent during fabrication, was found to cause permanent reduction in engineering properties of polyester and could have contributed to the reduction of the fatigue resistance. Fatigue properties of the polyester drive belt are reviewed for the operating condition, as well as the sensitivity of polyester to cleaning solvents and the origin of mechanically weak locations.
Recorder did not possess erase head nor was it capable of automatically rewinding reel of tape for reuse. Test results show that FM carrier recording signal with sufficient intensity will by itself erase previously recorded data as new data are being recorded. Automatic rewinding was accomplished by adding conventional metal leaders and appropriate circuitry.
Linear filter and detection theory can bear on problem of reconstructing recorded bit stream. Problem can be taken from realm of nonlinear problems even though basic record process is still recognized as highly nonlinear. Digital tape recorder can be modeled as particular type of linear communication channel with intersymbol interference.
A video tape recorder is disclosed of sufficient bandwidth to record monochrome television signals or standard NTSC field sequential color at current European and American standards. The system includes scan conversion means for instantaneous playback at scanning standards different from those at which the recording is being made.
The design, fabrication, and testing of an automatic bacteria detection system with a zero-g capability and based on the filter-capsule approach is described. This system is intended for monitoring the sterility of regenerated water in a spacecraft. The principle of detection is based on measuring the increase in chemiluminescence produced by the action of bacterial porphyrins (i.e., catalase, cytochromes, etc.) on a luminol-hydrogen peroxide mixture. Since viable as well as nonviable organisms initiate this luminescence, viable organisms are detected by comparing the signal of an incubated water sample with an unincubated control. Higher signals for the former indicate the presence of viable organisms. System features include disposable sealed sterile capsules, each containing a filter membrane, for processing discrete water samples and a tape transport for moving these capsules through a processing sequence which involves sample concentration, nutrient addition, incubation, a 4 Molar Urea wash and reaction with luminol-hydrogen peroxide in front of a photomultiplier tube. Liquids are introduced by means of a syringe needle which pierces a rubber septum contained in the wall of the capsule. Detection thresholds obtained with this unit towards E. coli and S. marcescens assuming a 400 ml water sample are indicated.
Spaceborne digital recorders must satisfy the conflicting requirements of maximum data storage of high-rate data (particularly for high-resolution sensor data) and a long life with high reliability (meaning rugged design and moderate head-to-tape speeds). The multitrack longitudinal (fixed head) recorder can successfully resolve this conflict and satisfy both requirements. An evolutionary machine is described which was originally designed to store and reproduce 30 minutes of 39.9-Mb/sec sensor data, for mission lives on the order of one year; newer designs have surpassed these parameters by significant amounts.
Telemetry data from the 'Copernicus' experiment stored on magnetic tape on the Ural-IX computer are transcribed to the internal memory of the IBM 360 computer. Operations involved in this process are described.
Real-time laser holographic interferometry technique has been applied successfully in the detection of 1mm x 1mm x 0.025mm duct tapes hidden beneath a 150mm x 150mm x 16mm ceramic-epoxy-fiberglass sandwiched structure. The experimental results clearly demonstrate future applicability of this technique in the optical nondestructive detection of debonds and flaws in such composite structures.
A set of long-chord stator vanes was designed to replace the vanes in an existing fan stage. The long vanes consisted of a turning section and axial extension pieces, both of which incorporated acoustic damping material. The acoustic damping material was made inactive for these tests by covering with metal tape, and the stator vanes were tested in three length configurations. Compared to the values for the original stage, broadband noise was reduced in the middle to high frequencies with the long stator vanes, but a broadband noise increase was observed at the low frequencies. No change was observed in the blade passage tone, but some aft end reduction in the overtones was observed.
Atmospheric trace constituents in the upper troposphere and lower stratosphere are now being measured as part of the NASA Global Atmospheric Sampling Program (GASP), using fully automated air sampling systems on board commercial 747 aircraft in routine airline service. Measurements of atmospheric ozone and related meteorological and flight information obtained during several GASP flights in March 1975 are now available from the National Climatic Center, Asheville, North Carolina. In addition to the data from the aircraft, tropopause pressure data obtained from the National Meteorological Center (NMC) archives for the dates of the flights are included. This report is the first of a series of reports which describes the data currently available from GASP, including flight routes and dates, instrumentation, the data processing procedure used, and data tape specifications.