Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “System control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

Multi-Agent Deep Reinforcement Learning for Realistic Distribution System Voltage Control Using PV Inverters

Over the last few decades, the deployment of distributed solar photovoltaic (PV) systems has increased consistently. High PV penetration could cause adverse effects on the grid, such as voltage violations. This paper proposes a new distributed soft actor-critic based multi-agent deep reinforcement learning (SAC-MADRL) control solution to minimize the PV real power curtailment while keeping the grid voltage in an acceptable range. New reward functions have been designed to coordinate different agents during the learning process, yielding improved convergence. Comparison results with other control methods on a real feeder in western Colorado U.S. with 80% penetration of PVs demonstrate that the proposed method has better capability of effectively regulating voltage while minimizing the PV real power curtailment.

distribution system↗

Reinforcement Learning-based Output Structured Feedback for Distributed Multi-Area Power System Frequency Control

Load frequency control (LFC) is a key factor to maintain the stable frequency in multi-area power systems. As the modern power systems evolve from centralized to decentralized paradigm, LFC needs to consider the decentralized scheme that considers limited information from the information-exchange graph for the generator control of each interconnected area. This paper aims to solve a data-driven constrained LQR problem with mean-variance risk constraints and output structured feedback, and applies this framework to solve the LFC problem in multi-area power systems. By reformulating the constrained optimization problem into a minimax problem, the stochastic gradient descent max-oracle (SGDmax) algorithm with zero-order policy gradient (ZOPG) is adopted to find the optimal feedback gain from the learning, while guaranteeing the convergence. In addition, to improve the adaptation of the proposed learning method to new or varying models, we construct an emulator grid that approximates the dynamics of a physical grid and performs training based on this model. Once the feedback gain is obtained from the emulator grid, it is applied to the physical grid with a robustness test to check whether the controller from the approximated emulator applies to the actual system. Numerical tests show that the obtained feedback controller can successfully control the frequency of each area, while mitigating the uncertainty from the loads, with reliable robustness that ensures the adaptability of the obtained feedback gain to the actual physical grid.

Kwon, Kyung-bin↗

Data-Driven Mean-Corrected Recursive Estimation-Based Optimal DER Dispatch for Distribution System Voltage Control

Recent advances in smart inverters offer opportunities to mitigate adverse grid impacts caused by high penetrations of distributed photovoltaics (PV) in distribution grids, such as voltage violations. Here, this paper proposes a novel measurement-driven optimal power flow (OPF)-based distributed energy resource management system (DERMS) voltage regulation via recursive sensitivity estimation informed coordinated control of distributed PV inverters. The proposed approach leverages available grid and controllable DER measurements, eliminating reliance on system model information while being adaptive and robust to volatile operating conditions. A mean-corrected recursive ridge regression (MCRRR) algorithm is proposed for sensitivity estimation, continuously refining the sensitivity model through a closed-form solution. It effectively manages varying grid operating conditions, such as changes in power injections and topology reconfiguration, to facilitate a time-varying update of the Load Sensitivity Factors (LSF). The proposed approach is formulated as a linear programming (LP) problem and is thus scalable to larger-scale distribution systems. Its effectiveness and efficiency are demonstrated on a realistic distribution feeder with high PV penetrations in Southern California, USA.

14 SOLAR ENERGY↗

Implementation Plan for Combined Heat and Power Systems VOLTTRON Controller: Performance Monitoring and Real-Time Commissioning Algorithm Verification

Building-integrated cooling, heating, and power (CHP) systems are more efficient than conventional systems at providing local power and thermal energy, and favorable fuel prices are bound to spur their increased adoption. However, to realize the full benefit of the CHP systems, we must ensure persistence of energy efficient operations. Much of the inefficiency in the current building operations can be eliminated by use of automated performance monitoring (PM), real-time commissioning verification (CxV) and automated fault detection and diagnostic (AFDD) tools. Automation can help system operators make intelligent decisions. Remote and continuous monitoring of system conditions and performance will enable better management and integration of CHP with existing building systems. Continuous PM, real-time CxV, and AFDD could alleviate burdens for operations staff, enhance operations and maintenance (O&M), and improve reliability of building and CHP systems. To address the O&M challenges and to provide a means to maximize the rate-of-return of building-integrated CHP systems, the Building Technologies Office (BTO) within the U.S. Department of Energy’s (DOE’s) Office of Energy Efficiency and Renewable Energy (EERE) initiated a project to design, develop, and field test a VOLTTRON™-based supervisory controller and associated open-source algorithms. These algorithms will ensure real-time optimal operation of a building-integrated CHP system, support electric grid reliability, and lead to achieving the goal of clean, efficient, reliable, and affordable next-generation integrated energy system. Previous report listed the components for which PM, real-time CxV, and AFDD algorithms will be developed, how the algorithms will be tested, and the metrics that will be used to validate the algorithms and their ease of deployment. Deployment of these algorithms in the field will result in a reduction in energy consumption of between 10% and 20% (for both CHP and conventional building systems). This report builds upon the previous report by detailing the process by which PNNL will implement performance monitoring and real-time commissioning algorithms for CHP systems in conjunction with the use of the VOLTTRON CHP economic dispatch agent in host facilities.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Impact of Blockchain Delay on Grid-Tied Solar Inverter Performance

This paper investigates the impact of the delay resulting from a blockchain, a promising security measure, for a hierarchical control system of inverters connected to the grid. The blockchain communication network is designed at the secondary control layer for resilience against cyberattacks. To represent the latency in the communication channel, a model is developed based on the complexity of the blockchain framework. Taking this model into account, this work evaluates the plant’s performance subject to communication delays, introduced by the blockchain, among the hierarchical control agents. In addition, this article considers an optimal model-based control strategy that performs the system’s internal control loop. The work shows that the blockchain’s delay size influences the convergence of the power supplied by the inverter to the reference at the point of common coupling. In the results section, real-time simulations on OPAL-RT are performed to test the resilience of two parallel inverters with increasing blockchain complexity.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Efficacy of vibro-impact energy harvesting absorbers on controlling dynamical systems under vortex-induced vibrations and base excitation

Here this study investigates improving the efficacy of an energy harvesting absorber's ability to control a structure under vortex-induced vibrations, base excitation, and a combination of the two by including mechanical amplitude stoppers. The nonlinear reduced-order model is developed through modifying trilinear spring models to represent the impact forces, a modified van der Pol oscillator to represent the forcing due to the vortex-induced vibrations and using the Euler-Lagrange principle to express the equations of motion. It is seen that a soft stopper stiffness and a 5mm gap performs the most effectively of increasing the power generated from the absorber while still greatly reducing the primary structure's amplitude. By changing the stopper's location towards the middle of the energy harvesting absorber, the large effects of the impact forces are reduced and improves the efficacy of medium and hard stopper stiffnesses to generate near the amount of power the soft stopper does, while greatly improving the control of the primary structure. When the system is under combined loadings, the large oscillations of the synchronization region cause the effective configuration to be that of a 27.5 mm gap with soft stiffnesses. The results shows that medium stiffness stoppers with small gaps generate large aperiodic regions due to the high impact force. When the oscillations are close to the stoppers, the beating phenomenon is observed and is not overpowered by the vibro-impact force.

16 TIDAL AND WAVE POWER↗

Model predictive current profile control in tokamaks by exploiting spatially moving electron cyclotron current drives

The plasma control systems in next-generation tokamaks like ITER will balance competing control objectives to achieve the desired level of performance in advanced scenarios while preventing magnetohydrodynamic instabilities and disruptions. During normal tokamak operation, the points of incidence of the electromagnetic waves generated by the electron cyclotron heating and current drives (EC H&CDs) are usually fixed in space. However, the points of incidence can be modified in real-time by changing the angles of the mirrors that reflect the EC H&CD waves. Altering the points of incidence, in turn, varies the ability of the plasma control system to regulate a plasma property. For instance, changing the EC H&CD wave incidence location may place the power demands necessary to achieve a particular plasma target within saturation limits. Therefore, using the EC H&CD deposition location, which is related to the EC H&CD mirror angle, as a supplementary controllable variable may facilitate access to a given target scenario. However, active scenario-control algorithms have not been designed so far to fully exploit this capability in real time. In this work, a model predictive controller that can handle actuation locations as control inputs is developed. In particular, the controller is designed to regulate both the auxiliary powers and the EC H&CD deposition locations in a pre-defined optimal sense to achieve the control objective of attaining and sustaining a target current profile. Further, the proposed controller is tested for a DIII-D tokamak scenario in nonlinear simulations using the Control Oriented Transport SIMulator (COTSIM).

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

PIP-II Beam Current Monitor Fault Case & Beam Position Monitor Linearity Studies in CST Studio

The use of non-invasive sensors & systems to measure particle beam characteristics is a crucial part of modern accelerator control systems. As such, simulations predicting the behavior of these sensors are essential for guiding beamline control system design. This poster details the results returned by two beam sensor models created using CST Studio software: the signal linearity of an elliptical beam position monitor (BPM), and the fault cases of an AC current transformer (ACCT) beam current monitor (BCM).

Rouzky, Adam↗

Autonomous Hydrogen Fueling Station

This project “Autonomous Hydrogen Fueling Station” covered the autonomous refueling with both gaseous hydrogen and liquid hydrogen. The part on gaseous hydrogen focused on the development of an autonomous robotic fueling arm that would couple to a fuel cell engine for hydrogen refueling without guidance from the forklift operator and budget period. Research was also covered for the robotic fueling with a commercial vehicle. The second phase of the project created the baseline for an autonomous liquid hydrogen transfer system that would minimize boil off losses by operating at thermodynamically efficient state points. For the development of the robotic fueling arm, testing was conducted to establish a baseline measurement of the accuracy and repeatability of a human operator positioning a lift truck in front of a dispenser. The goal was to establish the range of motion required for an autonomous fueling mechanism to mate a hydrogen nozzle with a receptacle on a fuel cell system installed in a forklift. The final design comprised a selective compliance articulated robot arm (SCARA)-type mechanism with two arms for horizontal motion and a ball screw for vertical movement and color and LIDAR cameras were used for marker identification and proximity awareness to guide the robotic arm to its target receptacle. Initial tests resulted in 199 out of 200 successful attempts at autonomous coupling of the dispensing coupler and a fuel cell engine, without hydrogen. The dispenser prototype was modified to include tubing for both hydrogen fuel and air purge lines, but subsequent tests were confounded by the shoulder motor over current errors which limited the robot from getting to the fully inserted position to achieve a positive latch. Robotic hydrogen refueling was successfully demonstrated over 1.5 hours of testing, Plug completed 29 successful latches with an average number of 4 sequential latches before failure. However, a robot capable of placing the nozzle with more force is required for higher reliability. For budget period two, a small scale (10 kg / transfer) automated control system was designed that would operate valves to control pressure and flow of liquid nitrogen between a source and receiving tank with an aim to minimize boil off losses by operating at the most thermodynamically efficient state points. Control system logic flow and a P&ID were developed prior to system safety characterization via HAZOP. A control narrative and system state points were defined. Delays in approval for a change of project objective and procurement issues precluded the construction and test of the final prototype system.

08 HYDROGEN↗

Connected and automated vehicles, driving systems, and control logic for info-rich eco-autonomous driving

A method for controlling automated driving operations of a vehicle includes determining vehicle origin and destination data, and generating a graphical representation of a road network with multiple candidate routes between the vehicle's origin and destination. Road-level data, including speed, turn angle, and/or gradient data, is received for each candidate route, and respective total energy uses are estimated for the vehicle to traverse across the candidate routes. Multiple candidate driving strategies, each having respective speed and acceleration profiles, are determined for the candidate route with the lowest estimated total energy use. An optimal candidate driving strategy is selected through a cost evaluation of the associated speed and acceleration profiles and forward movement simulations of the vehicle over a prediction horizon. Command signals are transmitted to the vehicle's steering and/or powertrain systems to execute control operations based on the optimal driving strategy and the candidate route with the lowest energy use.

Zhao, Junfeng↗

Crosstalk-Robust Quantum Control in Multimode Bosonic Systems

Universal control of multimode bosonic modes typically relies on a dispersively coupled transmon ancilla. However, its frequency undergoes a Stark shift that depends on the state of each coupled bosonic mode, leading to a frequency mismatch in the ancilla drive and ultimately reducing the fidelity of multimode gates

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

2025 Intern Poster

The Hot Fuel Examination Facility (HFEF) at the Materials and Fuels Complex (MFC) houses the largest U.S. inert atmosphere hot cell for nuclear material research. Key features include the precision gamma scanning (PGS), Fuel Accident Condition Simulator (FACS), Neutron Radiography Reactor (NRAD), and the focus of this project, the Metallograph Loading Cell (MET Cell). The MET Cell performs tests on spent nuclear fuel, such as microhardness testing, microscopy, and neutron radiography. However, the MET Cell’s existing pressure and lighting control systems are outdated and inefficient, with inadequate documentation for system changes over time. This project aims to design a new automated control system for the MET Cell, ensuring longevity (minimum ten years), ease of troubleshooting/repair, and integration into the building monitoring system. The design process addressed challenges such as space restrictions, varied voltages within enclosures, sourcing new components, and security limitations. Compliance with NFPA 70, UL508A, MFC Physical Security, and INL Engineering standards was essential. The project involves repurposing an existing PLC to manage lighting and pressure control using digital and analog signals, simplifying wiring, and ensuring thorough documentation for future reference.

42 - ENGINEERING↗

Self-regulating behavior of hybrid membrane systems as demonstrated in an element-scale forward osmosis-reverse osmosis hybrid system

Hybrid membrane systems can be difficult to design due to the requisite flow rate matching between up- and downstream unit operations. In this work, we use a forward osmosis-reverse osmosis (FO-RO) hybrid system to demonstrate how some membrane systems can exhibit self-regulating behavior due to osmotic coupling. This can reduce the need for complex control systems for flow balancing. We show this behavior using a module-scale test bed that can mimic the behavior of larger scale operations. The system shows permeate flow rate near-convergence between the FO and RO modules after startup or when perturbed by a change in RO module pressure. The behavior of this hybrid system demonstrates that some membrane operations can exploit osmotic interdependence, rather than expensive control systems, to achieve steady state operation.

Debottlenecking↗

A Robotics Enabled Eddy Current Testing System for Autonomous Inspection of Heat Exchanger Tubes

The objective of the project is to develop a robotics enabled eddy current testing system (REECTS) in automatic probe deployment, inspection, and data acquisition and analysis. The main functions of the REECTS are to: 1) identify geometry and locations of heat exchange tubes with assistance of an imaging recognition system; 2) precisely control the position and motion speed of ECT probes by an adaptive control system; 3) facilitate data analysis and real-time decision making for autonomous inspection assisted by machine learning algorithms.

20 FOSSIL-FUELED POWER PLANTS↗

Insights on the Effects of Magnetic Forces on the Efficiency of Vibration Energy Harvesting Absorbers in Controlling Dynamical Systems

This study investigates the effects of magnetic constraints on a piezoelectric energy harvesting absorber while simultaneously controlling a primary structure and harnessing energy. An accurate forcing representation of the magnetic force is investigated and developed. A reduced-order model is derived using the Euler–Lagrange principle, and the impact of the magnetic force is evaluated on the absorber’s static position and coupled natural frequency of the energy harvesting absorber and the coupled primary absorber system. The results show that attractive magnet configurations cannot improve the system substantially before pull-in occurs. A rigorous eigenvalue problem analysis is performed on the absorber’s substrate thickness and tip mass to effectively design an energy harvesting absorber for multiple initial gap sizes for the repulsive configurations. Then, the effects of the forcing amplitude on the primary structure absorber are studied and characterized by determining an effective design of the system for a simultaneous reduction in the primary structure’s motion and improvement in the harvester’s efficiency.

42 ENGINEERING↗

Cyber-Resilient Automatic Generation Control for Systems of AC Microgrids

In this paper we propose a co-design of the secondary frequency regulation in systems of AC microgrids and its cyber security solutions. We term the secondary frequency regulator a Micro-Automatic Generation Control (μ AGC) for highlighting its same functionality as the AGC in bulk power systems. We identify sensory challenges and cyber threats facing the μ AGC. To address the sensory challenges, we introduce a new microgrid model by exploiting the rank-one deficiency property of microgrid dynamics. This model is used to pose an optimal μ AGC control problem that is easily implemented, because it does not require fast frequency measurements. An end-to-end cyber security solution to the False Data Injection (FDI) attack detection and mitigation is developed for the proposed μ AGC. The front-end barrier of applying off-the-shelf algorithms for cyber attack detection is removed by introducing a data-driven modeling approach. Finally, we propose an observer-based corrective control for an islanded microgrid and a collaborative mitigation scheme in systems of AC microgrids. We demonstrate a collaborative role of systems of microgrids during cyber attacks. Furthermore, the performance of the proposed cyber-resilient μ AGC is tested in a system of two networked microgrids.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Enhancements and Deployment of the TDAQ System for the Mu2e Experiment

The Real Time Processing Systems Division at Fermilab has deployed new features to the Off-The-Shelf Data Acquisition framework (otsdaq) for the Mu2e experiment. The Mu2e experiment will search for the coherent neutrino-less conversion of a muon into an electron in the field of an aluminum nucleus with a sensitivity improvement of 10,000 times over existing limits. Such a charged lepton flavor-violating reaction probes new physics at a scale unavailable at present or planned high-energy colliders. The Mu2e Trigger and Data Acquisition (TDAQ) system uses otsdaq as its online Data Acquisition System (DAQ) framework. otsdaq integrates the artdaq and art frameworks for event transfer, filtering, and processing. otsdaq is a web-based DAQ software suite focusing on flexibility and scalability and provides a multi-user interface accessible through a web browser. artdaq handles the entire data stream, which is read over the peripheral component interconnect express (PCIe) bus to a software filter algorithm that selects events combined with the data flux coming from a cosmic-ray veto (CRV) system. Detector front-ends are configured through the PCIe bus by customized otsdaq plugins. The otsdaq slow controls infrastructure has been further developed using the experimental physics and industrial control system (EPICS) open-source platform for monitoring, controlling, alarming, and archiving. The detector control system (DCS) for Mu2e has been integrated into otsdaq. The production TDAQ and DCS system has been deployed at the experimental hall and is being debugged and optimized for experiment operations. We report on the feature enhancements and deployment of otsdaq for Mu2e.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Assessment of the Electrical Substation-Grid Testbed with Inside/Outside Devices and Distributed Ledger Technology

The electrical substation-grid testbed was created to integrate the GOOSE and/or DNP (Distributed Network Protocol) messages with time synchronized sources and Distributed Ledger Technology (DLT). The objective was to study the impact of faults and cyber-events at an electrical substation with inside (protective relays) and outside (power meters) substation devices. The electrical substation-grid testbed was based on the design of a 34.5/ 12.47 kV electrical substation (sectionalized bus configuration) with two power transformers, connected to radial power lines and load feeders. The electrical substation-grid testbed was installed at 252 lab space (Advanced Power System Protection), Grid Research Integration and Deployment Center (GRID-C), Oak Ridge National Laboratory. This testbed was created for Task 5, DarkNet project. The electrical substation-grid testbed was created to simulate fault and/or cyber events that could potentially result in damage to the electrical infrastructure. In addition, tests were run that are usually not allowed to be performed in an operational electrical power grid, because these test scenarios could trip breakers and/or generate fault situations that could potentially damage equipment. The number of tests performed in the electrical substation-grid testbed were executed in a better way than in a real electrical substation and/or power grid, because multiple tests could be run in a short period of time, and complex permits, and safety/ schedule restrictions like in a real electrical substation environment were not needed. The electrical substation-grid testbed was created using real measurement, communication, and protection devices that are used by electrical utilities, to have same conditions that we could observe in a real power grid or electrical substation. The electrical substation-grid testbed was based on using a real time simulator and expansion box with amplifiers that were wired to electrical substation-grid devices. This hardware-in-the-loop (HIL) was provided by protective relays, power meters, ethernet switches, remote terminal units, synchronized timing network clock, DLT devices, workstations, and servers. This report includes the design, installation, and assessment of the electrical substation-grid testbed that was similar to an operational electrical substation, integrating the power system protection, communication, and control systems. The results for the electrical substation-grid testbed were based on:• verifying the analog signals for protective relays and power meters, • observing the synchronized time source frame at devices, • authenticating the GOOSE (IEC 61850) and DNP messages from power meters and protective relays, and • verifying the trip conditions of protective relays at fault tests with the power system fault event detection, using DLT devices. For future work, the electrical substation-grid testbed with protective relays and power meters, using DLT and synchronized time source from DarkNet, will be used to study the impact of cyber-events at inside and outside substation devices. Advanced algorithms for detecting cyber-events produced by non-desired protective relay settings will be studied, to improve the detection and reliability of protection, control, and communication systems at power grids.

24 POWER TRANSMISSION AND DISTRIBUTION↗