Distributed Optimal Power Management for Battery Energy Storage Systems: A Novel Accelerated Tracking ADMM Approach

Optimal power management (OPM) is critical for large-scale battery energy storage systems. Today’s methods often require formidable computational effort due to the design based on centralized numerical optimization. Thus, this paper investigates computationally distributed OPM where the agents based on the cells communicate over a network to cooperatively solve the OPM problem. We propose an accelerated tracking alternating direction method of multipliers (ADMM) algorithm to solve the distributed OPM. The proposed algorithm embeds dynamic average consensus and Nesterov’s acceleration technique in the ADMM algorithm. Not only is the proposed algorithm fully distributed without a need for fusion or aggregating nodes, but it also accelerates convergence. The paper formulates the OPM in a model predictive control framework where it seeks to regulate the charging/discharging power of each battery cell to minimize the total power losses and promote balanced use of the constituent cells while complying with the safety constraints. The paper provides ample simulation results to demonstrate the effectiveness and advantages of the proposed distributed OPM in terms of computation and convergence.

Farakhor, Amir↗

Chemical and electrochemical behavior of the Cr(III)/Cr(II) half-cell in the iron-chromium redox energy storage system

The Cr(III) complexes present in the acidified chromium solutions used in the iron-chromium redox energy storage system have been isolated and identified as Cr(H2O)6(3+) and Cr(H2O)5Cl(2+) by ion-exchange chromatography and visible spectrophotometry. The cell reactions during charge-discharge cycles have been followed by means of visible spectrophotometry. The spectral bands were resolved into component peaks and concentrations of the Cr(III) species calculated using Beer's law. During the charge mode, Cr(H2O)5Cl(2+) is reduced to Cr(H2O)5Cl(+), and during the discharge mode Cr(H2O)5Cl(+) is oxidized back to Cr(H2O)5Cl(2+). Electrode potential measurements also support this interpretation. Hysteresis effects in the charge-discharge curves can be explained by the slow attainment of equilibrium between Cr(H2O)6(3+) and Cr(H2O)5Cl(2+).

Johnson, D. A.↗

OCTOKV: An Agile Network-Based Key-Value Storage System with Robust Load Orchestration

In this paper, we propose OctoKV, an innovative network-based key-value storage system. OctoKV addresses the repetitive address translation overhead associated with traditional key-value stores running on file systems on the client side. To mitigate this overhead, we implemented the key-value store on the server side using NVMe-oF and a user-level NVMe driver. In particular, we employed fine-grained resource monitoring and load balancing based on heuristics to optimize I/O performance. OctoKV is deployed on a Linux cluster with Intel SPDK. The extensive evaluation shows that OctoKV achieves lower I/O response times in comparison to traditional approaches where key-value stores run on the client side. Also, the proposed load balancing strategies efficiently enhance I/O response times by equally distributing the workload from overloaded cores to other cores.

Khan, Awais↗

A Novel Three-Phase Oak Ridge AC / AC Converter for Wireless Mobility Energy Storage System (WMESS) Connectivity

In this study, a novel three-phase Oak Ridge ac to ac converter is introduced for wireless mobility energy storage system (WMESS) applications for grid support or ancillary service applications. The proposed topology can be used in bidirectional operation between ac grid and ac terminals of energy storage (output of the ESS inverter) by accomplishing unity power factor. Inherent merit of the technology is that it can directly merge ac input 60 Hz grid frequency with the high frequency by superimposing them with the Oak Ridge Converter (ORC) and through the wireless coils. Theoretical and simulation results are provided for 10 kW output power. The functionality of the proposed three-phase system is demonstrated with the coupling coils separated by 6 inches of air gap with the input / output of 277 V AC,RMS . The system overall design is presented, and simulation results demonstrate achieving 3% current total harmonic distortion (THD) and 0.99 power factor (PF) at full load of 10 kW wireless power transfer.

Asa, Erdem↗

Design of a Thermal Energy Storage System for SMR's

A potential deployment strategy for Small Modular Reactors (SMR's) is in hybrid energy systems where the presence of intermittent energy sources (wind and/or solar) subjects the reactor to a time varying electric load (1). Proposed options for accommodating this load have included operating the reactor in a load follow mode, or operating the reactor at or near steady state and bypassing steam around the turbine directly to the condenser (2). Both of these strategies result in lost energy potential. With the large financial investment associated with a nuclear power plant there is strong economic incentive to run the plant at maximum capacity. One method to accomplish this is the installation of Thermal Energy Storage (TES) that can be charged when grid demand is less than 100% plant capacity. The thermal energy can then be recovered, either as a supplement to the power plant during peak demand times, or can be used for other processes (1). Sensible heat thermal energy storage systems have been proposed for solar energy systems (3). This paper describes such a system for SMRs. These results show the feasibility of a TES system alongside a nuclear power plant that can limit load following operations for the reactor. Load following results in a decrease of capacity factor for the plant along with imposing significant stresses to plant equipment. With the implementation of a TES system these stresses can be transferred from the nuclear plant to the TES system. Not only does this equate to a longer overall life of the plant's hardware, but it also will dramatically increase the capacity factor of the system. This increase in capacity factor will lead to an improved economic return over the lifespan of the reactor. Future development in the near term will focus on coupling the TES system to the dynamic response of the reactor and energy conversion system and developing the models necessary to implement the discharge mode. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Design and evaluation of thermodynamic vent/screen baffle cryogenic storage system

A comprehensive analytical program was performed to compare an integrated thermodynamic vent/screen baffle orbital cryogenic propellant storage and transfer system with other concepts. The screen systems were found to be 20% to 29% lighter in weight than a propulsively accelerated Tug-scale LH2/LO2 resupply module. The screen systems were compared with small-scale supercritical storage systems for the space shuttle fuel cell reactant and life support system fluid supply and were lighter by up to 556 kg (1225 lb) for the extended 30-day mission. When compared with high-pressure gas storage for the spacelab atmosphere supply, the screen system saved 79% of the inert system weight for the 30-day mission. An experimental program found that heat flux rates up to 9,450 watts/sq m (3,000 Btu/hr-sq ft) degraded the LH2 bubble point performance of eight screens by a maximum of 12.5%. No effects of helium pressurant, screen material, or LH2 superheat were observed.

Cady, E. C.↗

Liquid hydrogen storage system for heavy duty trucks: Configuration, performance, cost, and safety

In this work, we investigate the potential of liquid hydrogen storage (LH 2 ) on-board Class-8 heavy duty trucks to resolve many of the range, weight, volume, refueling time and cost issues associated with 350 or 700-bar compressed H 2 storage in Type-3 or Type-4 composite tanks. We present and discuss conceptual storage system configurations capable of supplying H 2 to fuel cells at 5-bar with or without on-board LH 2 pumps. Structural aspects of storing LH 2 in double walled, vacuum insulated, and low-pressure Type-1 tanks are investigated. Structural materials and insulation methods are discussed for service at cryogenic temperatures and mitigation of heat leak to prevent LH 2 boiloff. Failure modes of the liner and shell are identified and analyzed using the regulatory codes and detailed finite element (FE) methods. The conceptual systems are subjected to a Failure modes and effects analysis (FMEA) and a safety, codes, and standards (SCS) review to rank failures and identify safety gaps. The results indicate that the conceptual systems can reach 19.6% usable gravimetric capacity, 40.9 g-H 2 /L usable volumetric capacity and $174-183/kg-H 2 cost (2016 USD) when manufactured 100,000 systems annually.

08 HYDROGEN↗

Economic Analysis of Battery Energy Storage Systems Incorporating Uncertain Battery Model

A high-fidelity battery model is essential for precise economic analysis of battery energy storage systems (BESSs), but these models are computationally intensive. Heuristic models offer computational efficiency but compromise the accuracy of economic analysis results. We assess the impact of errors in heuristic battery models on economic analysis by utilizing open-circuit voltage (OCV) measurements from battery experiments.

Choi, Hyungjin [Sandia National Laboratories (SNL-↗

Electro-mechanical Modeling of Wind Turbine and Energy Storage Systems with Enhanced Inertial Response

In this paper, a coordinated control scheme for wind turbine generator (WTG) and supercapacitor energy storage system (ESS) is proposed for temporary frequency supports. Inertial control is designed by using generator torque limit considering the security of WTG system, while ESS releases its energy to compensate the sudden active power deficit during the recovery process of turbine rotor. WTG is modeled using the fatigue, aerodynamic, structure, turbulence (FAST) code, which identifies the mechanical loadings of the turbine and addresses electro-mechanical interactions in the wind energy system. A damping controller is augmented to the inertial control to suppress severe mechanical oscillations in the shaft and tower of the turbine during frequency supports. Furthermore, the result of small-signal stability analysis shows that the WTG-ESS tends to improve the stability of the whole multi-energy power grid. The major contributions of this paper will be validated by utilizing the proposed control method that combines the grid support capability and maintaining the integrity of structural design of the turbine for normal operations.

17 WIND ENERGY↗

A high efficiency motor/generator for magnetically suspended flywheel energy storage system

The authors discuss the theory and design of a brushless direct current motor for use in a flywheel energy storage system. The motor design is optimized for a nominal 4.5-in outside diameter operating within a speed range of 33,000-66,000 revolutions per minute with a 140-V maximum supply voltage. The equations which govern the motor's operation are used to compute a series of acceptable design parameter combinations for ideal operation. Engineering tradeoffs are then performed to minimize the irrecoverable energy loss while remaining within the design constraint boundaries. A final integrated structural design whose features allow it to be incorporated with the 500-Wh magnetically suspended flywheel is presented.

Niemeyer, W. L.↗

Analysis of Dust and Corrosion Witness Samples Recovered from SNF Dry Storage Systems, Maine Yankee, 2023

This report documents the results of a long-term (5.79 year) exposure of 4-point bend corrosion test samples in the inlet and outlet vents of four spent nuclear fuel dry storage systems at the Maine Yankee Independent Spent Fuel Storage Installation. The goal of the test was to evaluate the corrosiveness of salt aerosols in a realistic near-marine environment, providing a data set for improved understanding of stress corrosion cracking of spent nuclear fuel dry storage canisters. Examination of the samples after extraction showed minor corrosion was present, mostly on rough-ground surfaces. However, dye penetrant testing showed that no SCC cracks were present. Dust collected on coupons co-located with the corrosion specimens was analyzed by scanning electron microscopy and leached to determine the soluble salts present. The dust was mostly organic material (pollen and stellate trichomes), with lesser detrital mineral grains. Salts present were a mix of sea-salts and continental salts, with chloride dominating the anions, but significant amounts of nitrate were also present. Both corrosion samples and dust samples showed evidence of wetting, indicating entry of water into the vents. The results of this field test suggest that the environment at Maine Yankee is not highly aggressive, although extrapolation from the periodically wetted vent samples to the hot, dry, canister surface may be difficult. No stress corrosion cracks were observed, but minor corrosion was present despite high nitrate concentrations in the salts. These observations may help address the ongoing question of the importance of nitrate in suppressing corrosion and SCC.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Dry Canister Storage System Inspection and Robotic Delivery System Development

EPRI is working to develop and demonstrate technologies capable of inspecting welded stainless steel canisters used in dry cask storage systems in situ, without the need to remove them from their concrete casks. This involves the coupling of specialized cameras and inspection devices with small remotely operated vehicles (ROVs). The objective is to demonstrate the capability to identify any presence of (or precursors to) stress corrosion cracking (SCC) and other anomalies that may require additional investigation. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Low-Cost, Easy-To-Integrate and Reliable Grid Energy Storage System with 2 nd Life Lithium Batteries

Batteries retired from electric vehicles have the potential to extend their service as low-cost stationary energy storage systems. However, disperse battery state of health (SOH) and nonuniform battery characters often lead to compromised battery performance and reliability, which greatly hinder their adoption. A Heterogenous Unifying Battery (HUB) system is proposed to stage 2 nd life battery bricks for a period, and enable them to attain improved SOH uniformity, performance, and reliability before being sold for 2 nd life applications, while simultaneously providing grid services. It may offer a technically and economically advantageous solution for the broad utilization of 2 nd use batteries. The goal of this project was to develop the hardware and software that enables the key functions of the HUB system. The first achievement of the project was the development of a 1kW scale proof-of-concept (POC) system, which comprises (i) a modular plug-n-play DC-DC power converter matrix with isolated series output connections to achieve fully independent control of energy flow to each of the connected battery units at low voltage; (ii) enhanced model based control that drives each batteries’ SOH towards uniformity while collectively providing grid energy storage services; and (iii) comprehensive procedures to perform battery diagnostics and prognostics. The second achievement was the development of a 100kW scale HUB system and demonstrated its performance of re-establishing battery SOH uniformity through a period of battery cycling operation. The final HUB system incorporates six DC-DC power converter matrices paired with six battery bricks. Hot swapping of a single battery brick while maintaining consistent system power was demonstrated and system operation was validated to be capable of implementing the approved grid duty cycle and of balancing and conditioning the battery bricks. Through the course of the project, the team optimized the building-block design, form-factors, and adjusted life balancing control. An up-sized 250kW Scale was developed and deployed in October 2022 with pack-level battery form factors, see photo in Figure 1 The third achievement of the project was to perform a techno-economic analysis in order to better understand the cost and revenue potentials in this new “recondition-then-resell" value proposition. The final TEA quantified the economics of new Li-ion batteries as well as second-life batteries processed via reconditioning and traditional binning. Results showed the reconditioned second-life batteries in this project to be economically favorable and viable in grid energy storage markets. The TEA results were published in the Applied Energy journal. The fourth achievement of the project was to deliver a tech-to-market plan for the HUB system that includes funding, IP, and manufacturing strategies. The final T2M plan outlines a business strategy in which the HUB provides a B2B service to EV companies as an alternative to battery recycling that can prepare batteries for 2nd life applications. A company named Smartville Inc. was founded to carry on the commercialization, funding, and technical IP licensing activities of the OPEN project.

25 ENERGY STORAGE↗

SCALE ANALYSIS AND EXPERIMENTAL RESULTS OF A SOLID/LIQUID PHASE-CHANGE THERMAL ENERGY STORAGE SYSTEM

A detailed experimental study has been carried out to evaluate the heat transfer performance of a solid/liquid phasechange thermal energy storage system. The phase-change material (PCM) and metal foam are contained in a vertically oriented test cylinder that is cooled or heated at its outside boundary, resulting in radially inward melting, respectively. Detailed quantitative time-dependent volumetric temperature distributions and melt-front motion and shape data were obtained. As the PCM melts, the interface moves away from the surface of the heat source/sink, and a thermal resistance layer is built up, resulting in a reduced heat transfer rate and/or increased temperature difference between the system to be cooled (or heated) and the PCM. The phase-change medium was 99% pure eicosane, with a melting temperature of 36.5oC. Results have been generalized to apply to any low-Stefan number PCM. A heat transfer scale analysis was used in order to help in interpretation of the data and development of heat transfer correlations. In the scale analysis, conduction heat transfer in the solid and natural convection heat transfer in liquid were considered. Comparison of experimental data with scale-analysis predictions of the solid-liquid interface position and temperature distribution was performed.

25 ENERGY STORAGE↗