Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Steam Generator”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

Effects of Slag Composition on H{sub 2} Generation and Magnetic Precipitation from Molten Steelmaking Slag–Steam Reaction

In this paper, the effects of slag composition (slag basicity CaO/SiO{sub 2} and FeO concentration) on the amounts of H{sub 2} gas generated and the magnetic spinel phase precipitated as a result of the reaction between synthetic steelmaking slag and steam at 1873 K (1600 °C) were studied by thermodynamic simulation (using Thermodynamic Package FactSage 7.0) and laboratory experiments. The thermodynamic calculation showed that, upon increasing slag basicity (CaO/SiO{sub 2}) from 1.0 to 2.5, for the reaction of 100 g of slags with 100 g of H{sub 2}O gas, the accumulated amount of the produced H{sub 2} gas increased from 0.17 to 0.27 g, while the amount of magnetic spinel phase first increased and then decreased, with the maximum precipitation of 16.71 g at the basicity of 1.5. When the FeO concentration increased from 15 to 30 pct for the slag with basicity of 2.0, the accumulated amount of the produced H{sub 2} gas increased from 0.17 to 0.28 g, and the amount of magnetic spinel phase increased from 5.88 to 10.59 g. The laboratory experiments were conducted in confocal laser scanning microscope to verify the reaction between 0.2 g of slag and 3.75 L of H{sub 2}O-Ar gas (P{sub H{sub 2O}} =0.2 atm). The results indicated that, for 100 g of slags, upon increasing slag basicity (CaO/SiO{sub 2}) from 1.0 to 2.5, both the produced H{sub 2} gas and magnetic spinel phase first increased and then decreased, with the maximum amounts being 0.09 g of gas and 37.00 g of magnetic spinel phase at the slag basicity of 1.50. For the FeO concentration increasing from 15 to 30 pct, the amounts of both the produced H{sub 2} gas and magnetic spinel phase increased from 0.04 to 0.10 g and from 18.00 to 27.00 g, respectively. The reaction rate between the molten CaO-SiO{sub 2}-FeO-MnO-Al{sub 2}O{sub 3}-MgO slag and the moisture (P{sub H{sub 2O}} =0.2 atm) increased with the increasing FeO activity in the slag. The dependence of the reaction rate (mol/cm{sup 2}/s) on FeO content can be expressed as r =(7.67(a{sub FeO})−2.99)×10{sup −7}.

36 MATERIALS SCIENCE↗

Optimizing the Costs of Solid Sorbent-Based CO 2 Capture Process Through Heat Integration

The focus of this project was the ADAsorb™ CO 2 Capture Process, a temperature-swing adsorption process that incorporates a three-stage fluidized bed as the adsorber and a single-stage fluidized bed as the regenerator. ADAsorb™ system was designed, fabricated, and tested under DOE award DEFE0004343. Two amine-based sorbents were evaluated in conjunction with the ADAsorb™ process: “BN”, an ion-exchange resin; and “OJ”, a metal organic framework (MOF) sorbent. Two cross heat exchanger designs were evaluated for use between the adsorber and regenerator: moving bed and fluidized bed. The fluidized bed approach was rejected fairly early in the project because the additional electrical load to power blowers or fans to overcome the pressure drop required for fluidization was estimated to be nominally three times the electrical power that could be generated from the steam saved through the use of the cross heat exchanger. The Energy Research Center at Lehigh University built and utilized a process model of the ADAsorb™ capture process and integrated this model into an existing model of a supercritical PC power plant. The Lehigh models verified that, for the ADAsorb™ system, the largest contributor to parasitic power was lost electrical generation, which was primarily electric power which the host plant could not generate due to the extraction of low pressure (LP) steam for sorbent heating, followed by power for the CO 2 compressor and the blower or fan power required to fluidize the adsorber and regenerator. Sorbent characteristics such as the impacts of moisture uptake, optimized adsorption and regeneration temperature, and sensitivity to changes in pressure were also included in the modeling study. Results indicate that sorbents which adsorb more than 1-2% moisture by weight are unlikely to be cost competitive unless they have an extremely high CO 2 working capacity that well exceeds 15% by weight. Modeling also revealed that reductions in adsorber pressure drop could negatively affect the CO 2 adsorption characteristics for sorbents with certain isobar adsorption characteristics like sorbent BN. Thus, reductions in pressure drop do not provide the efficiency benefits expected. A techno-economic assessment conducted during the project revealed that without heat integration, the a metal organic framework (MOF) sorbent used in conjunction with the ADAsorb™ process provided the opportunity for improved performance over the benchmark MEA process. While the addition of a cross heat exchanger and heat integration was found to significantly improve net unit heat rate, the additional equipment costs required to realize these improvements almost always outweighed the improvement in performance. The exception to this was for a supported amine sorbent and the addition of a moving bed cross heat exchanger alone or in conjunction with waste heat from the compressor used for supplemental regenerator heating. Perhaps one of the most important points to be drawn from the work conducted during this project is the significant influence of sorbent characteristics alone on the projected COE and LCOE associated with the ADAsorb™ process, and the implications associated with future improvements to solid sorbent CO 2 capture. The results from this project suggest that solid sorbent CO 2 capture will continue to see performance gains and lower system costs as further sorbent improvements are realized.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Fuel-Cell Power Systems Incorporating Mg-Based H2 Generators

Two hydrogen generators based on reactions involving magnesium and steam have been proposed as means for generating the fuel (hydrogen gas) for such fuel-cell power systems as those to be used in the drive systems of advanced motor vehicles. The hydrogen generators would make it unnecessary to rely on any of the hydrogen storage systems developed thus far that are, variously, too expensive, too heavy, too bulky, and/or too unsafe to be practical. The two proposed hydrogen generators are denoted basic and advanced, respectively. In the basic hydrogen generator (see figure), steam at a temperature greater than or equals 330 C would be fed into a reactor charged with magnesium, wherein hydrogen would be released in the exothermic reaction Mg + H2O yields MgO + H2. The steam would be made in a flash boiler. To initiate the reaction, the boiler could be heated electrically by energy borrowed from a storage battery that would be recharged during normal operation of the associated fuel-cell subsystem. Once the reaction was underway, heat from the reaction would be fed to the boiler. If the boiler were made an integral part of the hydrogen-generator reactor vessel, then the problem of transfer of heat from the reactor to the boiler would be greatly simplified. A pump would be used to feed water from a storage tank to the boiler.

Kindler, Andrew↗

Water treatment capacity of forward osmosis systems utilizing power plant waste heat

Forward osmosis (FO) has the potential to improve the energy efficiency of membrane-based water treatment by leveraging waste heat from steam electric power generation as the primary driving force for separation. In this study, we develop a comprehensive FO process model, consisting of membrane separation, heat recovery, and draw solute regeneration (DSR) models. We quantitatively characterize three alternative processes for DSR: distillation, steam stripping, and air stripping. We then construct a mathematical model of the distillation process for DSR that incorporates hydrodynamics, mass and heat transport resistances, and reaction kinetics, and we integrate this into a model for the full FO process. Finally, we utilize this FO process model to derive a first-order approximation of the water production capacity given the rejected heat quantity and quality available at U.S. electric power facilities. We find that the upper bound of FO water treatment capacity using low-grade heat sources at electric power facilities exceeds process water treatment demand for boiler water make-up and flue gas desulfurization wastewater systems.

20 FOSSIL-FUELED POWER PLANTS↗

Repurposing Fossil-Fueled Assets For Energy Storage

The annual retirement of U.S. coal-fired electricity generation units (CF-EGU) is at an all-time high and is expected to continue. This loss of reliable baseload generation, combined with predicted growth of variable renewable energy (VRE) generation, is expected to stress grid reliability as the number of load-following resources drops below the experienced load variability. Many regions are already experiencing challenges, and fossil retirement-related warnings by the North American Electric Reliability Corp. are becoming more dire. All CF-EGU retirements pose significant challenges to asset owners, local workforces, and their communities. Repurposing a retiring CF-EGU as a long-duration energy storage plant can address these challenges and offer a suite of additional benefits to asset owners, the grid, and society. This project performed a techno-economic evaluation and assessment of repurposing a Duke Energy fossil-fueled asset (in particular, a coal plant) into an energy storage system by integrating the retiring asset with a Malta long duration Pumped Heat Energy Storage (PHES) system. The project validated the technoeconomic benefits of repurposing retiring coal plants into long-duration energy storage using Malta’s PHES. Key findings for this project are summarized below: (1) Technical: (a) Retiring coal plants (and other steam turbine fossil generation) can be repurposed to enable the clean energy transition using Malta’s technology. (b) For older retiring coal plants, repurposing the site and electrical interconnection for a standalone PHES plant is the most economically favorable option. (c) For newer coal plants where there is also a local peaking capacity need, repowering the steam cycle into a hybrid integration with PHES is attractive. (d) A process was developed to assist fossil generation owners in choosing the best path for each plant’s circumstances. (2) Economic (a) Communities facing economic challenges caused by the retirement of fossil generation would benefit from repurposing the plant as long-duration energy storage using Malta’s PHES. (b) On a $/MW basis, repowering retiring coal units into Malta PHES plants can maintain the same number and types of jobs and economic activity. (c) For a 70% carbon reduction scenario, a 10-hour Malta PHES plant is more economic for the asset owner than similar-power 4-hour batteries. This project showed that repurposing a retiring coal unit into thermal energy storage, by integrating it with a Malta PHES system, makes techno-economic sense. At least two integration options are available, with the optimal solution depending on the coal plant and its location. Repurposing retiring coal plant into energy storage results in economic benefits for the plant owner and local communities.

20 FOSSIL-FUELED POWER PLANTS↗

Pool Boiling CHF Experiment for Cr-alloy-coated Accident Tolerant Fuel Cladding

The severe accident at the Fukushima nuclear power plants forced the nuclear communities to revise and reinforce their safety technology, especially accident tolerance. The main problem of Zr-based alloys is hydrogen generation owing to steam oxidation in a very high temperature environment. Currently, several types of Accident Tolerant Fuel (ATF) claddings that eliminate the steam oxidation problem have been presented as alternatives. Although the ATFs have shown appropriate performances in terms of material engineering, thorough tests including thermal hydraulic concerns are still required to ensure the design compatibilities. In this study, we conducted pool boiling critical heat flux (CHF) experiments using Cr-alloy-coated ATF claddings to verify basic thermal hydraulic performances. (authors)

36 MATERIALS SCIENCE↗

Real-time dispatch optimization for concentrating solar power with thermal energy storage

Concentrating solar power (CSP) plants present a promising path towards utility-scale renewable energy. The power tower, or central receiver, configuration can achieve higher operating temperatures than other forms of CSP, and, like all forms of CSP, naturally pairs with comparatively inexpensive thermal energy storage, which allows CSP plants to dispatch electricity according to market price incentives and outside the hours of solar resource availability. Currently, CSP plants commonly include a steam Rankine power cycle and several heat exchange components to generate high-pressure steam using stored thermal energy. The efficiency of the steam Rankine cycle depends on the temperature of the plant's operating fluid, and so is a main concern of plant operators. However, the variable nature of the solar resource and the conservatism with which the receiver is operated prevent perfect control over the receiver outlet temperature. Therefore, during periods of solar variability, collection occurs at lower-than-design temperature. To support operator decisions in a real-time setting, we develop a revenue-maximizing non-convex mixed-integer, quadradically-constrained program which determines a dispatch schedule with sub-hourly time fidelity and considers temperature-dependent power cycle efficiency. The exact nonlinear formulation proves intractable for real-time decision support. Here we present exact and inexact techniques to improve problem tractability that include a hybrid nonlinear and linear formulation. Our approach admits solutions within approximately 3% of optimality, on average, within a five-minute time limit, demonstrating its usability for decision support in a real-time setting.

14 SOLAR ENERGY↗

Novel Foaming Solutions for High Level Waste (HLW) Processing - 20195

Foaming occurs during treatment of high level waste (HLW) at Savannah River Site's Defense Waste Processing Facility (DWPF) in the Chemical Process Cell (CPC) due to high gas generation from process steam and chemical offgas products [1]. The presence of amphiphilic particles in the waste slurry stabilizes the foam [2], [3]. Efficient processing of HLW requires foam control, as foam-overs lead to lower productivity and potential radioactive contamination of condensate streams. DWPF currently employs Siovation Antifoam 747, a surfactant produced by Momentive Performance Materials, as an antifoaming agent during waste treatment. Despite its ability to control foam generation, processing issues have arisen from its use [4]. During DWPF chemical processing, a chemical antifoam agent must be effective at temperatures up to 103 deg. C between pH 3-13. Antifoam 747 is effective at pH 7 but degrades as pH deviates [5]. Antifoam 747 is 90% by weight Momentive{sup TM} L77 and 10% by weight Momentive{sup TM} Y-17580. These ingredients are trisiloxane products, which are especially vulnerable to attack in acidic and caustic environments. Since Antifoam 747 readily degrades, periodic addition is required. Several processing concerns related to Antifoam 747 have affected DWPF operation. Its overuse warranted concern of potential flammable melter offgas under upset conditions due to the generation of carbon dioxide and hydrogen. As a result, a Potential Inadequacy in the Safety Analysis (PISA) was declared [6]. Antifoam contribution has been included in the melter offgas flammability strategy and the quantity of antifoam is monitored to ensure limits are not exceeded. Testing at Savannah River National Laboratory (SRNL) determined that propanal, tri-methylsilanol, and hexamethyldisiloxane are generated as Antifoam 747 degrades, leading to a second PISA [7]. The formation of these byproducts poses additional flammability risks. Furthermore, the methyl and ethyl groups of these compounds may be responsible for the formation of the methyl and ethyl mercury discovered in DWPF [8], [9]. The formation of organomercury has specifically been called out by DOE as a need for increased research. The effectiveness of non-chemical methods for foam control and the efficiency of alternative antifoam agents were evaluated as part of an effort to improve HLW treatment operations at DWPF and to reduce, or eliminate, the flammability hazards associated with Antifoam 747 currently in use. Foaming of high-level waste (HLW) slurries is an issue at the Defense Waste Processing Facility (DWPF) Chemical Process Cell (CPC) which is currently mitigated with a chemical antifoam agent. The effectiveness of non-chemical methods for foam control and the efficiency of alternative antifoams were examined to improve HLW treatment at DWPF and to eliminate the flammability hazards associated with Siovation Antifoam 747 currently in use. Non-chemical foam control methods were deemed unviable for chemical processing at DWPF, as the spray/mist technique requires too much water and space limitations make installation and implementation of headspace agitators unfeasible. The use of ultrasonic energy thickened and further stabilized the foam. Two suitable alternative defoaming agents, Momentive{sup TM} Y- 17112 and Evonik Surfynol{sup R} MD-20, were identified. Both defoamers control foam over a pH range of 4- 13 at boiling, with no flammable degradation products, and only minimal quantities (100-200 mg/kg) are required under glycolic acid conditions. In order to validate the effectiveness of these defoaming agents, SRNL recommends irradiation testing and laboratory scale SRAT/SME experiments with actual radioactive waste. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Technology for Electrically Enhanced Thermochemical Hydrogen (TEETH)

This is the Final Technical Report for the TEETH project. The TEETH concept couples high-temperature solar-thermochemical water splitting (TCWS) with electrochemical H 2 pumping through a proton conducting membrane (PCM) and capitalizes on the benefits of the individual technologies to synergistically providing new benefits. That is, TEETH is a coupled thermochemical/electrochemical process to produce H 2 from steam using solar energy. This approach is thermodynamically equivalent to other hybrid electrolytic processes but is unique in that the equilibrium of the reaction is driven forward by close coupling an electrically driven proton-conducting-membrane to the H 2 -producing reoxidation step. The process uniquely provides and benefits from the necessary H 2 /steam separation and, also unlike other hybrid processes, benefits thermodynamically from the use of readily generated high pressure steam. The concept also satisfies the objectives of previous concepts: 1) decreasing the reduction enthalpy (the reduction temperature), of the working metal-oxide (MO); 2) eliminating the need for a windowed receiver; and 3) widening the scope of material candidates, while also obviating the need for electrical connections to the working MO and avoiding the use of aqueous electrolytes and hydrated redox species (there is no liquid phase), without increasing mechanical complexity.

08 HYDROGEN↗

Magnetohydrodynamics (MHD) Engineering Test Facility (ETF) 200 MWe power plant. Conceptual Design Engineering Report (CDER). Volume 4: Supplementary engineering data

The reference conceptual design of the Magnetohydrodynamic Engineering Test Facility (ETF), a prototype 200 MWe coal-fired electric generating plant designed to demonstrate the commercial feasibility of open cycle MHD is summarized. Main elements of the design are identified and explained, and the rationale behind them is reviewed. Major systems and plant facilities are listed and discussed. Construction cost and schedule estimates, and identification of engineering issues that should be reexamined are also given. The latest (1980-1981) information from the MHD technology program are integrated with the elements of a conventional steam power electric generating plant. Supplementary Engineering Data (Issues, Background, Performance Assurance Plan, Design Details, System Design Descriptions and Related Drawings) is presented.

Source record↗

Liquid Salt Combined-Cycle Pilot Plant Design

The work described in this report is responsive to the Office of Fossil Energy program ‘Energy Storage for Fossil Power Generation.’ This Phase I report has been prepared by Pintail Power LLC, with support from Nexant ECA, Electric Power Research Institute (EPRI) and Southern Company Services as a deliverable for the U.S. Department of Energy for NETL Award DE-FE-00320016. The Liquid Salt Combined Cycle™ (LSCC™) technology provides large-scale energy storage integrated with Fossil Electric Generating Units (FEGUs) to meet critical needs in the energy transition by providing: • the lowest cost large-scale storage for time-shifting of renewable energy, • superior fuel efficiency to reduce GHGs from dispatchable resources, • flexible capacity and ramping to balance variability of wind and solar resources, • essential grid stability services to assure reliability of a low-carbon grid. The LSCC approach: • employs equipment that has already been proven in utility service, • uses safe, non-toxic, non-degrading, perpetual-life storage medium, • leverages and repurposes existing FEGU assets, • expands the value stack of energy storage to reduce market, financing, and commodity risks. Pintail Power has developed the LSCC technology to meet the need for reliable, efficient, and cost-effective integration of Variable Renewable Energy (VRE) into a low-carbon electric grid by coupling proven thermal energy storage with proven gas turbines, steam turbines, and heat transfer equipment. This novel approach is intended to address the key issues facing the grid and operators of renewable and fossil generating units including: • Overgeneration and curtailment of renewables, • Need for fast ramping dispatchable resources, • Improved efficiency and flexibility of fossil units, • Additional peaking capacity to support electrification of transportation and heating, • Provision of reliability services to support high penetration of VRE, especially synchronous inertia and fast frequency response. A Technology Readiness assessment by EPRI confirmed that LSCC technology consists of commercially proven hardware used in industrial and utility applications. Although the novel LSCC approach has not yet been demonstrated as a complete system, interfaces between major components have been conservatively specified. A Phase III pilot is planned to demonstrate equipment integration and operation. The patented innovation is removal of the evaporator section from the exhaust heat recovery system, with the evaporation performed by stored energy in a separate steam generator. This arrangement couples renewable and fossil power generation via long-duration energy storage to deliver cost, performance, and operational synergies, including superior charging and discharging flexibility, reduced fuel consumption and lower CO 2 emissions compared to conventional Combined Cycle Power Plants, and low-cost, large-scale energy storage. The LSCC technology is composed of proven equipment integrated with gas turbine exhaust heat in a novel system. During charging, electric heaters raise the salt temperature as it flows from the Cold Salt Tank to the Hot Salt Tank. During discharging, hot salt produces steam from feedwater that is heated with gas turbine exhaust, which also superheats steam to drive a steam turbine. LSCC technology can be added to any combustion-turbine to integrate renewable energy, provide needed grid services, and increase the value of fossil electric generating units based on the technology’s following attributes: • Long-duration storage enables time-shifting of VRE to avoid curtailment and impairment of renewable assets. • Long storage duration combined with fast-charging capability increases arbitrage opportunities by storing more energy when the price is low and discharging more hours when the price is high. • Long storage duration allows resource adequacy to be supplied across multiple days to increase reliability and reduce risk. • The stored energy reduces fuel heat rate and GHG emissions, and increases merit, so the LSCC dispatches earlier and longer to increase the plant’s capacity factor and asset value. • The stored energy enables pre-heating and startup of the steam cycle, without operating the gas turbine, to enable fast startup and ramping when dispatched for discharge. • The steam turbine can operate without the gas turbine so it can provide valuable synchronous inertia during charging without consuming fuel. • Fast frequency response and regulation services can be provided during charging using solid-state heater and pump controls to vary the charge power input in response to grid signals. • The LSCC system can be configured for resilience including black start, islanded/micro-grid operation, and even self-recharging of storage using either gas turbine power or gas turbine exhaust heat. The commercialization plan is to add LSCC technology to existing simple cycle gas turbine power plants with the 50MW GE LM6000 aero-derivative gas turbine as the reference design basis. A Techno-economic assessment of the reference design evaluated the benefits (Levelized Avoided Cost of Energy) and costs (Levelized Cost of Energy). The plant definition included all major systems and budgetary vendor quotes. Pintail Power and NexantECA developed the overall cost estimate for the LSCC plant up to the total plant cost level, following the DOE-NETL cost estimate guidelines at AACE Class 3 (-20%/+30%). This includes the equipment cost, bulk material, direct and indirect labor costs to arrive at the bare erected cost. Engineering costs are factored from the BEC and added to it to arrive at the EPC cost. Process and project contingencies were then factored from the EPC cost and rolled-up to yield the total plant cost of $\$$184 million for 1746 MWh of discharge electricity. • At $\$$105/kWh, the reference plant costs less than any of the Energy Storage Systems evaluated by PNNL in 2020 for the Energy Storage Grand Challenge. Operations and Maintenance cost estimates were scaled from combined cycle practice, assuming that the LSCC unit was co-located with and sharing some labor expense with other units, to arrive at $\$$2.2 million per year. Plant economics were evaluated using prices from the ERCOT Day-Ahead Market for calendar year 2019 (excluding the market disruptions from the COVID pandemic and the February 2020 deep freeze event). Assuming economic dispatch in the ERCOT Day-Ahead market, the reference plant capacity factor would have discharged for 2777 hours at 91.9 MW, a 31.66% capacity factor, with a marginal cost of $\$$25.59/MWh, and a LACE of $\$$82.41/MWh. Fixed charges were calculated according to EIA guidelines to arrive at an LCOE of $\$$83.48. The benefit-to-cost ratio of 0.99 suggests that the reference plant would have been cost-effective and competitive in the market. EPRI interviewed selected utilities to gauge the need for, applicability of and interest in the LSCC system. Several utilities are currently managing increased load growth along with the inclusion of increasing levels of renewable generation, putting pressure on conventional generation by requiring increased turndown requirements and ultimately lower capacity factors. All of the utilities interviewed have CO 2 reduction targets in the 2030-2050 timeframe that will severely limit the participation of fossil generation and require better utilization of carbon free generation. While there is limited opportunity for storage in the current markets, the utilities interviewed stated that there will be a substantial need for long duration energy storage in the future given the expected trends. Utilizing an energy storage system will generally be preferred over new gas capacity in some cases, with the capabilities of the LSCC system being a potential option for retrofit to existing simple cycle gas turbine units, allowing them to deliver greater participation in the market with lower carbon intensity. A technology gap assessment and technology maturation plan identified a pilot-scale demonstration as the final step before commercialization. Key gaps to be addressed during the Phase II FEED (Front-End Engineering Design) are component selection and design, commissioning procedures, and operational procedures and the control system for LSCC charging and discharging. The project team has been expanded to include Wood Group PLC as EPC. The proposed Phase II work leads to a pilot-scale engineering demonstration (TRL 6) to be conducted at Southern Company’s Plant Rowan, where the prototype system will perform “all the functions that will be required of the operational system.” The proposed pilot will facilitate commercialization (TRL-9) by scale-up to utility-scale systems integrated with peaking GTs or directly to facility scale systems using industrial GTs. The conceptual design for the pilot plant focuses on the novel integration aspects of LSCC technology. A slipstream of gas turbine exhaust will feed a waste heat recovery unit coupled to a molten salt steam generator heated by stored energy. The pilot is intended to demonstrate all key operating modes of the LSCC technology during charging, discharging and standby. The pilot equipment will be approximately one-seventh scale of the LM6000 commercial target and is expected to have commercial off-ramp potential for facility-scale applications.

01 COAL, LIGNITE, AND PEAT↗

Dissolution of Intermetallic Second-Phase Particles in Zircaloy-2 in High-Temperature Steam

The stability of intermetallic second-phase particles (SPPs) in coated Zircaloy-2 was studied in 700 °C steam environments up to 20 hours. Hydrogen generated from high-temperature steam oxidation of uncoated Zr-induced δ-hydrides formation in the Zircaloy matrix. Synchrotron XRD demonstrated that longer exposure times increased hydride peak intensity and decreased intermetallic SPPs’ peak intensity. Cross-sectional SEM analysis verified the intermetallic SPPs’ volume fraction reduction. The size distribution of intermetallic SPPs was characterized and larger particles were dissolved at longer oxidation time. Finally, a correlation between the hydrogen concentration and the volume fraction of intermetallic SPPs at 700 °C steam environment was found, with the volume fraction of SPPs decreasing as hydrogen concentration increases.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Study of optimum propellant production facilities for launch of space shuttle vehicles

An integrated propellant manufacturing plant and distribution system located at Kennedy Space Center is studied. The initial planned propellant and pressurant production amounted to 160 tons/day (TPD) LH2, 10 TPD GH2, 800 TPD LO2, 400 TPD LN2, and 120 TPD GN2. This was based on a shuttle launch frequency of 104 per year. During the study, developments occurred which may lower cryogen requirements. A variety of plant and processing equipment sizes and costs are considered for redundancy and supply level considerations. Steam reforming is compared to partial oxidation as a means of generating hydrogen. Electric motors, steam turbines, and gas turbines are evaluated for driving compression equipment. Various sites on and off Government property are considered to determine tradeoffs between costs and problems directly associated with the site, product delivery and storage costs, raw material costs, and energy costs. Coproduction of other products such as deuterium, methanol, and ammonia are considered. Legal questions are discussed concerning a private company's liabilities and its rights to market commercial products under Government tax and cost shelters.

Laclair, L. M.↗

Performance and flexibility improvements of Staged Pressurized Oxy-Combustion

Staged Pressurized Oxy-Combustion (SPOC) is a low-carbon coal combustion power technology being developed by Washington University in St. Louis (WUSTL). Oxy-combustion plants enable straightforward capture of carbon dioxide (CO 2 ) by removing most of the nitrogen in the combustion air prior to use, thereby burning fuel in near-pure oxygen instead of air, producing a flue gas containing primarily CO 2 and water. CO 2 capture at amounts > 90% is possible, often using cryogenic air separation. Oxy-combustion typically relies on flue gas recycle (FGR) to reduce the peak temperature and radiation that would otherwise occur in a fuel/oxygen only flame. SPOC reduces the peak temperatures of combustion by utilizing two or more pressurized boiler modules connected in series to produce fuel staging; hence, only a portion of the fuel is combusted in any given furnace module. This means that the thermal energy released at each stage can be captured and removed from the gases prior to subsequent stages, when more fuel is introduced. This allows the SPOC process to operate with minimal FGR, avoiding the associated efficiency losses and additional costs. Also, the process operates at an elevated gas-side pressure, reducing boiler size, enhancing heat transfer to achieve a compact boiler configuration as compared to an atmospheric-pressure boiler design, and allowing for recovery of the latent heat of the water from the flue gas at a temperature useful to the steam cycle. The resultant net efficiency of the system is over 3 percentage points greater than traditional atmospheric-pressure oxy-combustion, and 7 percentage points greater than the post combustion variant, representing a step-change improvement over first-generation capture technologies. To further develop the concept, WUSTL and the Electric Power Research Institute, Inc., organized a project with American Air Liquide, Inc., Doosan Babcock Limited, and the U.S. Department of Energy to investigate a practicable and workable boiler design. The team has identified the potential for enhanced process flexibility for controlling power generation over a wider load range than is normally available to conventional coal-fired power plants due to the staged nature of the heat release. With increasing intermittent renewable generator contribution, on-demand generators need to be highly flexible to participate in the future energy market, requiring extensive operation at reduced load. Conventional coal-fired steam generators typically face challenges in maintaining temperature control of the reheat steam and main steam at reduced loads. This results in inefficient operation, both in terms of the boiler efficiency and steam turbine heat rate. The results of this project show the SPOC process is capable of exceptional turndown, both on a stage basis and with the ability to bypass entire stages. Oxygen-supply flexibility was also investigated, as this is also a key consideration for the overall flexibility of the SPOC process given the operating constraints of conventional air separation units. A boiler design concept assessment was conducted and was focused on delivering compact and constructible design. The assessment checked appropriate tube operating metal temperatures at full load and at lower operating loads, balanced against the needs of efficient coal combustion, and the resultant slagging and ash environments. Combustion testing in the 100-kWth pressurized combustion test rig at WUSTL was carried out to validate the combustion, heat flux profiles and burnout at multiple loads. Combustion parameters investigated were flame stability, fuel burnout, ash composition, radiative heat flux, and temperature profiles. The results of these tests formed the basis of a full-scale boiler design that will encompass improvements in both efficiency and flexibility over conventional oxy-combustion processes. The air separation unit flexibility was investigated, and associated cost implications were addressed. Detailed economic assessment results for a 550 MWe net power block are also provided, allowing for a comparison against the baseline NETL oxy-combustion and post combustion capture cases.

20 FOSSIL-FUELED POWER PLANTS↗

Making Coal Relevant for Small Scale Applications: Modular Gasification for Syngas/Engine CHP Applications in Challenging Environments

This Front-End Engineering Design (FEED) study is funded by the US Department of Energy (DOE), and managed by the National Energy Technology Laboratory (NETL) through a Cooperative Agreement awarded to the University of Alaska Fairbanks (UAF) to perform a technical and cost study for the design and installation of a Hamilton-Maurer International (HMI) gasifier for generating a clean syngas for firing in reciprocating engines. An existing diesel engine generator (DEG) and a commercially available spark ignition engine are used to generate electricity with the low-Btu syngas. Other than the HMI gasifier, only commercially available technologies were assumed for this study. An important objective of this design study was to estimate capital and operating costs of small modular coal and coal/biomass fired generating units to provide wind regulation services. Although this study is based on retrofitting an existing coal fired power plant with the HMI gasifier, sufficient data was developed to characterize greenfield units. The original concept was to provide clean syngas and tars/oils from the gasification process to the existing Colt-Pielstick PC2.6B diesel engine generator (9.6 MWe) installed at the UAF Atkinson Power Plant. The intent was to convert the diesel engine to operate in a dual fuel mode, firing both syngas and tars/oils. As the project progressed, Fairbanks Morse Engine (FME), current licensee for the Colt-Pielstick engine line, was not able to develop a modification package for the engine to allow for syngas firing. Although this type of modification is available for firing natural gas, the capability does not extend to syngas. Western Energy Systems, distributor for Innio Jenbacher, was able to offer the Jenbacher Model JMS620 engine. After review of available options, the project team selected a design configuration using two Jenbacher engines rated at 1965 kWe each to fire the syngas, with the oils/tars directed to the Colt Pielstick diesel to be blended with ultra-low sulfur diesel oil (ULSD). The Jenbacher engines are expected to operate at continuous base load, with some load-following ability, while the existing diesel engine will operate in grid support service, with loads varying from a nominal 25% to 100%. An annual capacity factor for the diesel engine is projected to be between 50% and 60%. The overall gasifier and gas clean-up system is sized to produce enough syngas to adequately fuel three Jenbacher Engines for a nominal power output of 5.9 MWe, but this study assumes that only two Jenbacher engines will be installed due to space constraints in the Atkinson Power Plant, and because of expected air emission permit limitations. There is still potential that the excess syngas capacity equivalent to about 2 MWe could be used as supplemental fuel for the DEG. The exhaust from the Jenbacher engines is passed through heat recovery units to generate low pressure steam, thereby providing a significant portion of the steam required for operating the gasifier. The overall performance of the HMI gasifier/engine configuration is summarized as follows: 1) Overall electric efficiency, Jenbacher and diesel engines, based on gasifier fuel production (syngas and pyrolysis liquids) is 35.2% LHV, 2) Overall cogenerating efficiency (electricity plus steam), based on gasifier fuel production (syngas and pyrolysis liquids) is 54.8% LHV, 3) Overall electric efficiency, Jenbacher and diesel engines, based on coal input, is 29.6% LHV, and 4) Overall cogenerating efficiency, electricity plus steam, based on coal input is 46.0%. This project is estimated to have a Bare Erected Cost (BEC) of $\$$ 33.4 million and a Total Plant Cost (TPC) of $\$$ 45.7 million. Based on the original scope, sending both the clean syngas and the oils and tars to the existing diesel engine, the BEC and TPC values would have been $\$$ 23.3 million and $\$$ 32.1 million, respectively. A variable Cost of Electricity (COE) is calculated to reflect only those costs that will be incurred by incremental operation of the system for the HMI gasifier/Jenbacher engine combination. Operation of the diesel engine is determined separately. The variable COE values are: Case 1: 100% Usibelli Coal: (a) HMI gasifier/Jenbacher Engines -- 8.3 cents/kWh; (b) Diesel Engine -- 20.2 cents/kWh, and Case 2: 80% Usibelli Coal + 20% wood chips (proportion based on Btu input, LHV basis): (a) HMI Gasifier/Jenbacher -- 13.7 cents/kWh; (b) Diesel Engine -- 20.2 cents/kWh. The incremental cost of operating the gasifier/Jenbacher system increases with co-firing of wood chips due to the high cost of this material, over five times as costly as Usibelli coal delivered to the Atkinson Power building. The diesel cost is constant as the oils and tars are priced at the same value as the ULSD for the purposes of fueling the diesel engine. Section 8 of this report provides details of the O&M costs. The overall power system is configured to be modular and scalable to provide a wide range of generating capacity using the same components. This allows for reduction in cost, risk, schedule time to engineer and construct, and provides some degree of repeatability for air permitting.

01 COAL, LIGNITE, AND PEAT↗

Fatigue Performance of an Improved Creep Strength 10%Cr Steel

The deployment of 9-12% Cr steels for elevated temperature applications up to 650 °C presents a cost-effective alternative to more expensive nickel-based alloys in steam turbine power generation. To enhance creep resistance at this temperature range, a novel ferritic-martensitic steel, designated CPJ7, was developed and fabricated at the National Energy Technology Laboratory. The alloy design aimed to mitigate the transformation of strengthening carbides into deleterious phases that degrade creep performance. Results have demonstrated that CPJ7 exhibits favorable creep and oxidation resistance at 650 °C. However, its fatigue performance remains unexplored. This study builds upon prior research by evaluating the low cycle fatigue behavior of CPJ7 and verifying that modifications beneficial to creep performance were not detrimental to the fatigue performance. The alloy was tested at both 650 °C and ambient temperature under fully reversed bending conditions (R = − 1) and a load ratio of 0.05. Furthermore, the alloy exhibits cyclic softening, a behavior consistent with other 9-10 wt.% Cr steels. Analysis of the microstructure and hysteresis loops further corroborate cyclic softening mechanisms typical of ferritic-martensitic steels. Overall, the fatigue performance of CPJ7 meets or exceeds that of P91 steel, demonstrating its potential for high-temperature structural applications.

9% Cr ferritic-martensitic steel↗

Biorefinery for combined production of jet fuel and ethanol from lipid‐producing sugarcane: a techno‐economic evaluation

Abstract Replacing fossil fuels with an economically viable green alternative at scale has proved most challenging in the aviation sector. Recently sugarcane, the most productive crop on the planet, has been engineered to accumulate lipids. This opens the way for production of far more industrial vegetable oil per acre than previously possible. This study performs techno‐economic feasibility analysis of jet fuel production from this new cost efficient and high yield feedstock. A comprehensive process model for biorefinery producing hydrotreated jet fuel (from lipids) and ethanol (from sugars), with 1 600 000 MT yr −1 lipid‐cane processing capacity, was developed in SuperPro Designer. Considering lipid‐cane development is continuing for higher oil concentrations, analysis was performed with lipid‐cane containing 5%, 10%, 15%, and 20% lipids. Capital investments for the biorefinery ranged from 238.1 to 351.2 million USD , with jet fuel capacities of 12.6–50.5 million liters (correspondingly ethanol production of nil to 102.6 million liters). The production cost of jet fuel for different scenarios was estimated $0.73 to $1.79 per liter ($2.74 to $6.76 per gal) of jet fuel. In all cases, the cost of raw materials accounted for more than 70% of total operational cost. Biorefinery was observed self‐sustainable for steam and electricity requirement, because of in‐house steam and electricity generation from burning of bagasse. Minimum fuel selling prices with a 10% discount rate for 20% lipid case was estimated $1.40/L ($5.31/gal), which was lower than most of the reported prices of renewable jet fuel produced from other oil crops and algae. Along with lower production costs, lipid‐cane could produce as high as 16 times the jet fuel (6307 L ha −1 ) per unit land than that of other oil crops and do so using low‐value land unsuited to most other crops, while being highly water and nitrogen use efficient.

09 BIOMASS FUELS↗