Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “STOPPING POWER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

Role of electrons in collision cascades in solids. I. Dissipative model

In this article, we present a detailed model for the nonadiabatic coupling between ions and electrons in energetic ion-solid interactions over a wide range of energies in concentrated solid-solution fcc alloys of the 3d transition metals Ni, Co, Fe, and Cr. The model is based on general statistical mechanical principles and results in a stochastic modification of the classical nuclei motion which is parameterized by the first-principles calculation of a dissipation function produced by explicit time-dependent electronic evolution. This model provides a full picture of an entire collision process, from the ballistic to the thermal phases of a cascade, giving a detailed description of the energy exchange between ions and electrons till their final thermalization, removing in this way some ad hoc assumptions used in the state-of-the-art atomistic two-temperature models. Here, this work is separated in two papers; in the present Part I, we report on the ab initio methodology used to translate stopping power and electron-phonon interaction into a parameterized dissipation function; Part II, to be published, addresses the nonadiabatic ion dynamics using our modified Langevin dynamics [Tamm et al. Phys. Rev. Lett. 120, 185501 (2018)] applying the dissipation functions developed here to specific collision cascade events.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Role of electrons in collision cascades in solids. II. Molecular dynamics

In this work, we present a model for the role of electrons in collision cascades in solids in which the coupling between ions and electrons is calculated using first-principles models and introduced into the classical ion equations of motion using our modified Langevin dynamics [A. Tamm et al., Phys. Rev. Lett. 120, 185501 (2018)]. This model gives a full picture of the entire collision process, from the ballistic to the thermal phases of a cascade, giving a detailed representation of the energy exchange between ions and electrons until their final thermalization, removing in this way some ad hoc assumptions used in the state-of-the-art two-temperature model. This work is separated into two papers: Part I [M. Caro et al., Phys. Rev. B 99, 174301 (2019)] reports on the ab initio methodology used to translate stopping power into the parametrized dissipation function. Finally, part II applies the nonadiabatic ion dynamics using the dissipation functions developed in Part I to specific collision cascade events.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Modern version of the uncited 1938 experiment that first observed DT fusion

Experiments are described, and results are provided, for the duplication of the first-ever triton-deuterium (colloquially referred to as DT) fusion experiment accidentally performed by A.J. Ruhlig in 1938, but forgotten in the published scientific literature. Here, we find that Ruhlig overestimated the ratio of the triton-deuterium over deuteron-deuterium neutron yields in his secondary reaction (Reaction-in-Flight) experiment compared to modern theoretical calculations and our duplication of his experiment using modern neutron detection methods. Nevertheless, Ruhlig’s observation provided the motivation for the application of DT fusion after World War II and its more recent importance in peaceful energy production at DT fusion facilities around the world. Additionally, the experimental technique used in the present work provides a novel approach for checking on low-energy triton stopping powers in deuterium containing compounds.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Kinetic simulations of fusion ignition with hot-spot ablator mix

Inertial confinement fusion fuel suffers increased x-ray radiation losses when carbon from the capsule ablator mixes into the hot-spot. Here, we present one- and two-dimensional ion Vlasov-Fokker-Planck simulations that resolve hot-spot self-heating in the presence of a localized spike of carbon mix, totalling 1.9% of the hot-spot mass. The mix region cools and contracts over tens of picoseconds, increasing its α particle stopping power and radiative losses. Furthermore, this makes a localized mix region more severe than an equal amount of uniformly distributed mix. There is also a purely kinetic effect that reduces fusion reactivity by several percent, since faster ions in the tail of the distribution are absorbed by the mix region. Radiative cooling and contraction of the spike induces fluid motion, causing neutron spectrum broadening. This artificially increases the inferred experimental ion temperatures and gives line of sight variations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Measurements of ion stopping around the Bragg peak in high-energy-density plasmas

For the first time, quantitative measurements of ion stopping at energies about the Bragg peak (or peak ion stopping, which occurs at an ion velocity comparable to the average thermal electron velocity), and its dependence on electron temperature (T e ) and electron number density (n e ) in the range of 0.5 – 4.0 keV and 3 × 10 22 – 3 × 10 23 cm -3 have been conducted, respectively. It is experimentally demonstrated that the position and amplitude of the Bragg peak varies strongly with T e with n e . As a result, the importance of including quantum diffraction is also demonstrated in the stopping-power modeling of High-Energy-Density Plasmas.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Core Electrons in the Electronic Stopping of Heavy Ions

Electronic stopping power in the keV / Å range is accurately measured from first principles for high atomic-number projectiles and the effect of core states is carefully assessed. The energy loss to electrons in self-irradiated nickel is researched using real-time time-dependent density functional theory. Different core states are explicitly included in the simulations to understand their involvement in the dissipation mechanism. The core electrons of the projectile are found to open additional dissipation channels as the projectile velocity increases. Almost all of the energy loss is accounted for, even for high projectile velocities, when core electrons as deep as 2s 2 2p 6 are explicitly treated. In addition to their expected excitation at high velocities, a flapping dynamical response of the projectile core electrons is observed at intermediate velocities. The empirical reference data are well reproduced in the projectile velocity range of 1.0–12.0 a.u. (1.5–210 MeV).

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Particle-in-cell simulations of burning inertial confinement fusion capsule implosions

Anomalies observed in the neutron spectral shift of high-yield shots at the National Ignition Facility (NIF) suggest the presence of suprathermal ions [E. P. Hartouni et al., Nat. Phys. 19, 72 (2023)], implying that kinetic effects play a significant role in burning inertial confinement fusion (ICF) plasmas. Furthermore, recent measurements of reaction-in-flight (RIF) neutrons offer a direct probe of the stopping power in the burning fuel region of high-energy alpha particles and up-scattered fuel ions. We have developed the particle-in-cell code PICNIC, an exactly energy-conserving particle-in-cell Monte-Carlo collision (PIC-MCC) code to simulate the burn stage in ICF. We present results from 1D spherical simulations of NIF shot N210808, which was the first to exceed the Lawson criterion for laser fusion. We find that the suprathermal ions generated by large-angle Rutherford and nuclear elastic scattering (NES) with fusion alphas produce an alpha knock-on neutron (AKN) signal consistent with the extent and relative yield of the AKN spectrum identified in ignition experiments at the NIF. Furthermore, we also find that the inclusion of large-angle scattering physics does not explain the anomalously large spectral shift observed in the experiment.

High-energy-density plasmas↗

The crystal structure of TlMgCl 3 from 290 K to 725 K

The title compound, thallium magnesium trichloride, has been identified as a scintillator with both moderate gamma-stopping power and moderate light yield. Knowledge of its crystal structure is needed for further development. This work determines the crystal structure of TlMgCl 3 to be hexa­gonal P6 3 /mmc (No. 194) and isostructural with RbMgCl 3 , contrary to previously reported data. This structure was obtained by single-crystal X-ray diffraction and was further confirmed by neutron diffraction measurements. Extending neutron diffraction measurements to high temperature, the data show that TlMgCl 3 maintains this crystal structure from 290 K up through 725 K, approaching the melting point of 770 K. Anisotropic thermal expansion coefficients increase over this temperature range, from 31 to 38 × 10 –6 K –1 along the a axis and from 19 to 34 × 10 –6 K –1 along the c axis.

36 MATERIALS SCIENCE↗

Particle-Tracking Proton Computed Tomography—Data Acquisition, Preprocessing, and Preconditioning

Proton CT (pCT) is a promising new imaging technique that can reconstruct relative stopping power (RSP) more accurately than x-ray CT in each cubic millimeter voxel of the patient. This, in turn, will result in better proton range accuracy and, therefore, smaller planned tumor volumes (PTV). The hardware description and some reconstructed images have previously been reported. In a series of two contributions, we focus on presenting the software algorithms that convert pCT detector data to the final reconstructed pCT images for application in proton treatment planning. There were several options on how to accomplish this, and we will describe our solutions at each stage of the data processing chain. In the first paper of this series, we present the data acquisition with the pCT tracking and energy-range detectors and how the data are preprocessed, including the conversion to the well-formatted track information from tracking data and water-equivalent path length from the data of a calibrated multi-stage energy-range detector. These preprocessed data are then used for the initial image formation with an FDK cone-beam CT algorithm. The output of data acquisition, preprocessing, and FDK reconstruction is presented along with illustrative imaging results for two phantoms, including a pediatric head phantom. The second paper in this series will demonstrate the use of iterative solvers in conjunction with the superiorization methodology to further improve the images resulting from the upfront FDK image reconstruction and the implementation of these algorithms on a hybrid CPU/GPU computer cluster.

42 ENGINEERING↗

Gamma-ray Spectra from a 3x3 CsPbBr 3 Array

CsPbBr 3 is a promising semiconductor material for X- and γ-ray detection at room temperature due to a wide bandgap of 2.3eV, high stopping power, and relatively high mobility-lifetime products of electrons and holes, and the capability of growing large crystals. In this paper we report on fabrication and testing of a 3.8 mm thick, 3 X 3 array with 1.2 mm pitch. Raw 137 Cs spectra were acquired with applied bias of 400 V, 500 V, and 600 V. Energy resolution of between 2 and 3 % FWHM at 662 keV was obtained from most pixels without any correction at room temperature. After 15 days under continuous bias at 600 V, no polarization effects were observed.

36 MATERIALS SCIENCE↗

Modelling a Transition-Edge Sensor X-Ray Microcalorimeter Linear Array for Compton Profile Measurements and Energy Dispersive Diffraction

Transition-edge sensors (TES) are a type of superconducting detector that offers high energy resolution based on their sharp resistance-temperature feature in the superconducting-to-normal transition. TES X-ray microcalorimeters have typically been designed and used for spectroscopic applications. In this work, we present a design optimization for a TES X-ray microcalorimeter array for high-energy scattering and diffraction measurements. Specifically, Compton scattering provides information about the electron momentum distribution, while energy dispersive diffraction provides structural information about dense engineering materials. Compton scattering and energy dispersive diffraction experiments must be conducted in the very hard X-ray regime (~100 keV), demanding a high X-ray stopping power in the detector; therefore, an absorber with a large heat capacity is needed in conjunction with the TES. In addition, both applications would benefit from an array composed of parallel strips. We propose a design for a TES X-ray microcalorimeter optimized for such applications. In particular, we model the longitudinal position dependence due to the finite thermal diffusion time in the absorber.

47 OTHER INSTRUMENTATION↗

How Excitation Conditions Alter the Afterglow Characteristics of CsI:Tl,Sm Microcolumnar Films

Combining high light output with the microcolumnar structure, the CsI:Tl films significantly reduce the need for painful tradeoff between thickness (hence, stopping power) and spatial resolution. But both films and monocrystals share two important deficiencies that hinder their use in many high-speed imaging and computed tomography applications: a persistent afterglow and hysteresis. These properties receive the primary attention of this investigation. In our earlier work, we reported that codoping with Sm 2+ brings about a significant reduction in the afterglow of CsI:Tl. Here, focusing on the microcolumnar films, we examine this afterglow-suppressive effect over a wide range of exposure times, from milliseconds to seconds, and at temperatures between 0 °C and 60 °C. Our measurements reveal well-defined dependences on both parameters. At room temperature (20 °C), defined as the normal operating condition, a 10-ms X-ray pulse leaves an afterglow from the standard (Sm-free) CsI:Tl of about 1% at 2 ms after the end of the pulse, changing little as a function of pulselength. Doping with Sm 2+ , however, reduces that afterglow by at least an order of magnitude, although somewhat less so after longer (100 and 1000 ms) pulses. When we change the temperature, however, we find markedly different behavior. Here, we find that a temperature increase of only 60°, without changing the pulselength, cuts the afterglow of standard CsI:Tl films by a factor of 20. However, films of codoped CsI:Tl,Sm, whose afterglow has already been suppressed by the presence of Sm 2+ , show much less change as a function of either temperature or pulse duration. It is the presence of Sm 2+ that makes the biggest difference. As for hysteresis, we again see an improvement, with the performance of the codoped CsI:Tl,Sm films bettering that of the standard (Sm-free) films. After an exposure of 300 mR, the change in light output falls to within 1% of the original after 1 min, whereas standard CsI:Tl films require 30 min to reach the same level.

42 ENGINEERING↗

Thermal Characterization of Tl 2 LiYCl 6 :Ce (TLYC)

Tl 2 LiYCl 6 :Ce (TLYC) is a new dual-detection elpasolite scintillator that can detect and distinguish between gamma rays and neutrons using pulse shape discrimination (PSD). It has a higher density and Z -number than the more mature and well-known elpasolite Cs 2 LiYCl 6 :Ce (CLYC), causing it to have a significantly better gamma-ray stopping power. These properties make TLYC an attractive alternative to CLYC for resource-constrained applications where size and weight are important, such as space or national security applications. Such applications may be subjected to a wide range of temperatures, and therefore, TLYC's performance was characterized for the first time over a temperature range of -20 °C to +50 °C in 10 °C increments. TLYC's thermal response effects on light-output linearity with energy, gamma-ray photopeak energy resolution, detected neutron energy, pulse shapes, and figure of merit (FOM) is analyzed and reported. The light output of TLYC was found to be linear with energy over the tested temperature range and was observed to decrease with increasing temperature. The decay time of the scintillation light output was observed to decrease with decreasing temperature at short times, leading to a decreasing PSD FOM. The gamma-ray photopeak energy resolution was also observed to degrade with decreasing temperature, due to an asymmetric broadening of the photopeak at low temperatures.

36 MATERIALS SCIENCE↗

Center-of-Mass Corrections in Associated Particle Imaging

Associated particle imaging (API) utilizes the inelastic scattering of neutrons produced in deuterium-tritium (DT) fusion reactions to obtain 3-D isotopic distributions within an object. The locations of the inelastic scattering centers are calculated by measuring the arrival time and position of the associated alpha particle produced in the fusion reactions, and the arrival time of the prompt gamma created in the neutron scattering event. While the neutron and its associated particle move in opposite directions in the center-of-mass (COM) system, in the laboratory system the angle is slightly less than 180°, and the COM movement must be taken into account in the reconstruction of the scattering location. Furthermore, the fusion reactions are produced by ions of different momenta, and thus the COM velocity varies, resulting in an uncertainty in the reconstructed positions. In this article, we analyze the COM corrections to this reconstruction by simulating the energy loss of beam ions in the target material and identifying sources of uncertainty in these corrections. Here we show that an average COM velocity calculated using the ion beam direction and energy can be used in the reconstruction and discuss errors as a function of ion beam energy, composition, and alpha detection location. When accounting for the COM effect, the mean of the reconstructed locations can be considered a correctable systematic error leading to a shift/tilt in the reconstruction. However, the distribution of reconstructed locations also have a spread that will introduce an error in the reconstruction that cannot be corrected. In this article, we will use the known stopping powers of ions in materials and reaction cross sections to examine the reconstruction uncertainties. We also discuss the impact of this effect on our API system.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Flash electropolishing for TEM: Reducing FIB‐induced defects in tungsten with protocols for new materials

Focused ion beam (FIB) milling has become the dominant approach for site-specific transmission electron microscopy (TEM) specimen preparation; however, FIB damage remains a critical limitation for reliable microstructural characterisation, particularly in radiation effects studies. Tungsten is especially susceptible to FIB damage due to its high nuclear stopping power, which promotes the formation and strong diffraction contrast of FIB-induced ‘black spot’ defects that are indistinguishable from very fine irradiation-induced loops/defects resulting from low to intermediate temperature neutron irradiation. In this work, flash electropolishing is systematically evaluated as a post-FIB treatment for minimising preparation-induced artefacts for TEM analysis of tungsten-based alloys. Using a range of non-, ion-, and neutron-irradiated tungsten materials, the effectiveness of flash electropolishing has been assessed through direct comparison with conventional FIB and plasma-FIB preparation including low-energy Ga, Ar, Xe ion cleaning. The results demonstrate that flash electropolishing effectively removes FIB-damaged layers and ‘black spot’ defects, thereby enabling reliable observation of irradiation-induced dislocation structures. Key processing parameters governing flash electropolishing quality – including lamella thickness, applied voltage, polishing duration, electrolyte chemistry, and cathode geometry – have been systematically evaluated, and clear criteria were established for determining when flash electropolishing is required to ensure reliable microstructural analysis. This work also provides practical guidance for implementing flash electropolishing as an artefact-controlled specimen-preparation approach for TEM characterisation of FIB-produced specimens. The systematic protocol can be extended to other, non-tungsten materials.

TEM sample preparation↗

Gold leaf phantom development for the assessment of proton radiographic sensitivity limits simulating gold nanoparticle tagged tumors

Proton radiography may guide proton therapy cancer treatments with beam’s-eye-view anatomical images and a proton-based estimation of proton stopping power. However, without contrast enhancement, proton radiography will not be able to distinguish tumor from tissue. To provide this contrast, functionalized, high-Z nanoparticles that specifically target a tumor could be injected into a patient before imaging. We conducted this study to understand the ability of gold, as a high-Z, biologically compatible tracer, to differentiate tumors from surrounding tissue. We indicate that AuNP-enhanced proton radiography might be a feasible technology to provide image-guidance to proton therapy, potentially reducing off-target effects and sparing nearby tissue. These data can be used to develop treatment plans and clinical applications can be derived from the simulations.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Comparison of GEANT4 very low energy cross section models with experimental data in water

Purpose: The GEANT4 general-purpose Monte Carlo simulation toolkit is able to simulate physical interaction processes of electrons, hydrogen and helium atoms with charge states (H{sup 0}, H{sup +}) and (He{sup 0}, He{sup +}, He{sup 2+}), respectively, in liquid water, the main component of biological systems, down to the electron volt regime and the submicrometer scale, providing GEANT4 users with the so-called ''GEANT4-DNA'' physics models suitable for microdosimetry simulation applications. The corresponding software has been recently re-engineered in order to provide GEANT4 users with a coherent and unique approach to the simulation of electromagnetic interactions within the GEANT4 toolkit framework (since GEANT4 version 9.3 beta). This work presents a quantitative comparison of these physics models with a collection of experimental data in water collected from the literature. Methods: An evaluation of the closeness between the total and differential cross section models available in the GEANT4 toolkit for microdosimetry and experimental reference data is performed using a dedicated statistical toolkit that includes the Kolmogorov-Smirnov statistical test. The authors used experimental data acquired in water vapor as direct measurements in the liquid phase are not yet available in the literature. Comparisons with several recommendations are also presented. Results: The authors have assessed the compatibility of experimental data with GEANT4 microdosimetry models by means of quantitative methods. The results show that microdosimetric measurements in liquid water are necessary to assess quantitatively the validity of the software implementation for the liquid water phase. Nevertheless, a comparison with existing experimental data in water vapor provides a qualitative appreciation of the plausibility of the simulation models. The existing reference data themselves should undergo a critical interpretation and selection, as some of the series exhibit significant deviations from each other. Conclusions: The GEANT4-DNA physics models available in the GEANT4 toolkit have been compared in this article to available experimental data in the water vapor phase as well as to several published recommendations on the mass stopping power. These models represent a first step in the extension of the GEANT4 Monte Carlo toolkit to the simulation of biological effects of ionizing radiation.

61 RADIATION PROTECTION AND DOSIMETRY↗

Investigation of radiological properties and water equivalency of PRESAGE dosimeters

Purpose: PRESAGE is a dosimeter made of polyurethane, which is suitable for 3D dosimetry in modern radiation treatment techniques. Since an ideal dosimeter is radiologically water equivalent, the authors investigated water equivalency and the radiological properties of three different PRESAGE formulations that differ primarily in their elemental compositions. Two of the formulations are new and have lower halogen content than the original formulation. Methods: The radiological water equivalence was assessed by comparing the densities, interaction probabilities, and radiation dosimetry properties of the three different PRESAGE formulations to the corresponding values for water. The relative depth doses were calculated using Monte Carlo methods for 50, 100, 200, and 350 kVp and 6 MV x-ray beams. Results: The mass densities of the three PRESAGE formulations varied from 5.3% higher than that of water to as much as 10% higher than that of water for the original formulation. The probability of photoelectric absorption in the three different PRESAGE formulations varied from 2.2 times greater than that of water for the new formulations to 3.5 times greater than that of water for the original formulation. The mass attenuation coefficient for the three formulations is 12%-50% higher than the value for water. These differences occur over an energy range (10-100 keV) in which the photoelectric effect is the dominant interaction. The collision mass stopping powers of the relatively lower halogen-containing PRESAGE formulations also exhibit marginally better water equivalency than the original higher halogen-containing PRESAGE formulation. Furthermore, the depth dose curves for the lower halogen-containing PRESAGE formulations are slightly closer to that of water for a 6 MV beam. In the kilovoltage energy range, the depth dose curves for the lower halogen-containing PRESAGE formulations are in better agreement with water than the original PRESAGE formulation. Conclusions: Based on the results of this study, the new PRESAGE formulations with lower halogen content are more radiologically water equivalent overall than the original formulation. This indicates that the new PRESAGE formulations are better suited to clinical applications and are more accurate dosimeters and phantoms than the original PRESAGE formulation. While correction factors are still needed to convert the dose measured by the dosimeter to an absorbed dose in water in the kilovoltage energy range, these correction factors are considerably smaller for the new PRESAGE formulations compared to the original PRESAGE and the existing polymer gel dosimeters.

60 APPLIED LIFE SCIENCES↗