Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SOURCE TERMS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

Development and scaling of MeV x-ray radiography at NIF-ARC

We investigate the generation of MeV x-rays using the Advanced Radiography Capability laser system at the National Ignition Facility using 1, 10, and 38 ps pulse durations, with laser energies reaching up to 4 kJ and using compound parabolic concentrators. Hydrodynamic simulations using up-to-date measurements of the contrast of the ARC laser are conducted, allowing us to employ an electron scaling model that incorporates scale length and pulse duration, which aligns closely with the observed temperature distributions. Comparable x-ray sources, in terms of dose, are generated when using a 10 ps pulse duration with 2.4 kJ at ∼1.9 ± 0.4 × 10 18 W/cm 2 and when using a 38 ps pulse duration with 4 kJ at 9.9 ± 0.4 × 10 17 W/cm 2 , both achieving ∼16 rad in air at 1 m for x-ray energies > 0.5 MeV. Radiographs performed on the laser “line-of-sight” show significant improvements in image quality than radiographs performed at 65 degrees to the laser axis. We verify the radiography performance using Monte Carlo Simulations.

Physics - Plasma physics↗

Best Practices for Shielding Analyses of Activated Metals and Spent Resins from Reactor Operation

This report investigated best practices for performing shielding evaluations of Type B waste packages, as defined in 10 CFR Part 71 regulations on packaging and transportation of radioactive material, or packages for which the contents are not defined before loading and may include a broad range of nuclides, geometries, and non-fuel materials. The following non-fuel waste streams were analyzed: Activated metals from decommissioned commercial power reactors, including Type 304 stainless steel, reactor vessel steel, and Inconel, Control blades from boiling water reactors, Neutron-activated corrosion products on surfaces of activated metals, and Spent resins from power plant operations. Measured elemental compositions, including major constituents and impurities, for steel and Inconel samples from commercial power reactors were used in activation calculations to determine radionuclide inventories in activated metals. For a simplified cask model, 60 Co contribution to the total external package dose rate at 30 days after shutdown varied from approximately 60% to 95%, depending on the activated metal, initial cobalt impurity concentration in the metal, and the thickness of the overpack gamma shield. Its maximum contribution to the total external package dose rate of approximately 100% was reached within the time interval of 2 to 5 years after shutdown and was maintained for up to 45 to 60 years after shutdown, depending on material, initial cobalt impurity concentration, and shield thickness. Thereafter, the 60 Co contribution to external package dose rate decreased with increasing decay time. Cobalt-60 is primarily produced by neutron reactions with the cobalt impurity in steel and Inconel. Other important radionuclides in activated metals contributing to package external dose rate are radionuclides with relatively short decay times, including 51 Cr, 59 Fe, 58 Co, and 54 Mn. These radionuclides may be represented as an equivalent 60 Co activity/source because 60 Co gamma ray emissions are bounding in terms of source strength and energy to other important radionuclides identified in the analyzed activated metals. Approaches for modeling the neutron-activated corrosion products that may be attached to activated reactor components were analyzed in this report. It was demonstrated that a surface source is more conservative than a uniform volumetric source for the treatment of neutron-activated corrosion products with respect to external package dose rates. An analysis of the maximum radionuclide loadings reported on spent resins identified the radionuclides 137 Cs, 60 Co, 134 Cs, 65 Zn, and 58 Co as the primary contributors to external package dose rate. For a resin cooled for 3.08 years, the external package dose rate was entirely produced by the reported 137 Cs and 60 Co inventory. The neutron sources from actinides found on spent resins or activated metals produced negligible dose rates and may be ignored in dose rate analyses. Effects of idealized waste material, source geometry, and spatial material/source distributions on external package dose rates were determined based on dose rate results for a simplified cask model under normal conditions of transport. Type 304 stainless steel, zirconium, and aluminum with adjusted mass densities based on a maximum content weight were analyzed for material modeling effects on external package dose rate. These materials produced identical external package dose rates within the statistical uncertainties of the dose rate estimates. Among four different source geometry configurations with homogeneous material of different mass densities, uniform volumetric source distribution, and the same source strength, the geometry configuration with lowest mass density (i.e., minimum self-shielding effect among the four cases) was most conservative. Spatial source distributions that better represent localized peak 60 Co activity values were more conservative than a uniform volumetric source distribution, assuming the same weight and total source strength per package. The increase in external dose rate caused by localized source peaks can be as much as the ratio between source peak activity density to average activity density, depending on the location of the activated metal with peak activity density. Therefore, the shielding analysis may be simplified if localized peak activities and the average activity per package can be measured/determined and documented at the time of cask loading. For simplicity, external package dose rates may be determined based on average source activity and a uniform volumetric source distribution. The dose rate results from that calculation model multiplied by the ratio of peak activity density to average activity density will produce maximum dose rate values for conservative estimates.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Cost-Optimized Cold Climate Heat Pump Development and Field Test

Cold climate heat pumps (CCHPs) expand the heat pump market to climates where heating demand is dominant. They can achieve more than 70% energy savings compared with electric resistance heating and operate at lower cost than using tank-stored propane to fuel a furnace. A high-efficiency heat pump with a heating seasonal performance factor (HSPF)—as defined by the Air-Conditioning, Heating, and Refrigeration Institute (AHRI 2008)—greater than 10.0 would be more efficient than gas heating in terms of source energy. However, developing a cost-effective CCHP involves some challenges. A typical single-speed, air-source heat pump (ASHP) with an HSPF of 7.7 Btu/Wh does not work well under cold outdoor temperature conditions typical of cold climate locations for four major reasons: 1. Discharge temperature is too high—The low suction pressure and high compression pressure ratio at low ambient temperatures causes high compressor discharge temperatures in excess of the maximum limit for many of the compressors on the market. Furthermore, system charge of a heat pump is usually optimized in the cooling mode, which leads to overcharge conditions in the heating mode, further increasing the discharge temperature. 2. Heating capacity is insufficient if sized to meet the building design cooling load— Heating capacity of a single-speed heat pump decreases with ambient temperature. The heating capacity at -13°F (-25°C) typically decreases to 20%–40% of the rated heating capacity at 47°F (8.3°C) (~equivalent to the rated cooling capacity at 95°F [35°C]). Therefore, a single-speed heat pump, typically sized to match the building design cooling load, cannot provide adequate heating capacity to match the building heating load at low ambient temperatures. The capacity deficit is filled by inefficient resistance heat, thus lowering the system efficiency and significantly increasing power demand. 3. Cyclic loss is significant if sized to meet the building design heating load—If a single-speed heat pump is sized to meet the heating load, it will be significantly oversized relative to the cooling load in many cold climates. This will cause excessive on/off cyclic loss during the cooling and heating operations at moderately low ambient temperatures. Thus, capacity modulation capability (e.g., using a variable-speed or multi-stage compressor) is necessary for a CCHP, which uses its full capacity to meet the peak heating load and partial capacity to meet the cooling and part-load heating loads. 4. Coefficient of performance (COP) is low—Heating COP degrades significantly at low ambient temperatures owing to the large temperature difference between the heat source and sink. A target CCHP should be sized to meet the building design heating load while minimizing the cyclic loss for the cooling and heating operations at moderate ambient temperatures.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Improved Understanding of Airborne Release Fraction and Respirable Fraction from Postulated Free-Fall Spill in DOE Nuclear Facilities (Annual Project Summary Report for NSRD-38)

The two-year experimental project has been completed to update the Airborne Release and Respirable Fraction (ARF and RF) estimates from the free-fall spills of liquid waste simulants. The objectives of the project at the Savannah River National Laboratory (SRNL) are to: (1) establish a technically defensible bounding approach for a reasonably conservative limit to the fall height used in the Ballinger correlation for the ARF, such that spill heights for near-water density liquid solutions above a critical height result in the same value of the ARF; and (2) provide a revised technical basis and data to support the ARF and RF correlation for free-fall liquid spills of heights from 1 to 10 meters. After peer review, these data and associated correlation will be available for consideration in a revision to DOE-HDBK-3010, Airborne Release Fractions/Rates and Respirable Fractions for Nonreactor Nuclear Facilities.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Safety Analysis of Chromium-Coated Accident-Tolerant Fuels with Increased Enrichment and Extended Burnup [Slides]

This report documents research and development conducted in support of deployment of accident-tolerant fuels. Specifically, the performance of chromium coating during a beyond design basis accident was investigated. An 18m reference core was considered, and the performance of cases with and without chromium coating compared. An extended cycle length of 24m was then considered with the chromium coating, to determine if the benefit of using the chromium coating was more or less significant than the increased fission product inventory when considering fission product release. The chromium coating model utilized here is a preliminary implementation and further work is recommended on a more detailed model.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Improved PARE (Pressurized Airborne Release Equipment) for Damage Ratio, Airborne Release Fraction and Respirable Fraction Testing (Version 4)

This paper describes an improved version of the PARE (Pressurized Airborne Release Equipment) system (Sutter 1983a and Sutter 1983b and Ballinger et al 1987) for powder venting testing. This effort seeks to improve the accuracy of risk estimation for the venting of pressurized powders and the venting of gases through pressurized powders. This includes experimental measurement for estimating DR (damage ratio), ARF (airborne release fraction) and RF (respirable fraction) quantities. The present study was performed to address previously indicated problematic factors (i.e. noted gaps) (US DOE 1994).

42 ENGINEERING↗

Molten Salt in the Advanced Test Reactor [Slides]

The Advanced Test Reactor (ATR) is one of the world’s most important resources for fuel qualification. Prior to this project, ATR could not support molten salt irradiation experiments. This work expands ATR’s capability to support fuel qualification for molten salt reactors.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Variability and Spectral Characteristics of Three Flaring Gamma-Ray Quasars Observed by VERITAS and Fermi-LAT

Flat-spectrum radio quasars (FSRQs) are the most luminous blazars at GeV energies but only rarely emit detectable fluxes of TeV gamma rays, typically during bright GeV flares. We explore the gamma-ray variability and spectral characteristics of three FSRQs that have been observed at GeV and TeV energies by Fermi-LAT and VERITAS, making use of almost 100 hr of VERITAS observations spread over 10 yr: 3C 279, PKS 1222+216, and Ton 599. We explain the GeV flux distributions of the sources in terms of a model derived from a stochastic differential equation describing fluctuations in the magnetic field in the accretion disk and estimate the timescales of magnetic flux accumulation and stochastic instabilities in their accretion disks. We identify distinct flares using a procedure based on Bayesian blocks and analyze their daily and subdaily variability and gamma-ray energy spectra. Using observations from VERITAS, as well as Fermi, Swift, and the Steward Observatory, we model the broadband spectral energy distributions of PKS 1222+216 and Ton 599 during very high energy (VHE)–detected flares in 2014 and 2017, respectively, strongly constraining the jet Doppler factors and gamma-ray emission region locations during these events. Finally, we place theoretical constraints on the potential production of PeV-scale neutrinos during these VHE flares.

79 ASTRONOMY AND ASTROPHYSICS↗

PSA 2025 Presentation: "Modeling and Sensitivity Analysis of a Generation IV Pebble Bed Reactor Using MELCOR 2.2"

Accompanying the advancement of reactor technologies is the need for computational modeling and simulation to predict their behavior under normal operating conditions and accident scenarios. New Generation IV reactor designs which employ non-conventional fuel have a particular need for modeling the behavior and release of radionuclides and other material from the fuel. In this work, MELCOR version 2.2, a system-level safety and accident scenario code developed by Sandia National Laboratories, was used to model a 200-MWth pebble bed modular reactor and calculate the inventories of circulating and deposited graphite, metal dust, and elemental components released from the fuel elements. A base case modeling the reactor under standard operating conditions was calculated using MELCOR and the inventories were extrapolated to 30 years of operation time using a logarithmic regression fit. A sensitivity analysis was also performed in which several key parameters for the base case model were modified to explore the effect of these changes on the inventories calculated by MELCOR. A set of transient scenario simulations for a depressurized loss of forced cooling (DLOFC) accident were also performed. The results of the sensitivity analysis and transient simulations are reported and discussed in relation to the modeling techniques used for this study.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

General Overview of Mobile Sources Used for Well Logging and Industrial Radiography Applications

Mobile sources is a term most commonly used to describe radioactive sources that are used in applications requiring frequent transportation. Such radioactive sources are in common use world-wide where typical applications include radiographic non-destructive evaluation (NDE) and oil and gas well logging, among others requiring lesser amounts of radioactivity. This report provides a general overview of mobile sources used for well logging and industrial radiography applications including radionuclides used, equipment, and alternative technologies. Information presented here has been extracted from a larger study on common mobile radiation sources and their use.

47 OTHER INSTRUMENTATION↗

Control of a Three-Phase Grid-Connected Voltage-Sourced Converter Using Long Short-Term Memory Networks

With the rise of inverter-based resources (IBRs) within the power system, the control of grid-connected converters (GCCs) has become pertinent due to the fact they interface IBRs to the grid. The conventional method of control for a GCC such as the voltage-sourced converter (VSC) is through a decoupled control loop in the synchronous reference frame. However, this model-based control method is sensitive to parameter changes causing deterioration in controller performance. Data-driven approaches such as machine learning can be utilized to design controllers that are capable of operating GCCs in various system conditions. This work explores a deep learning-based control method for a three-phase grid-connected VSC, specifically utilizing a long short-term memory (LSTM) network for robust control. Simulations of a conventional controlled VSC are conducted using Simulink to collect data for training the LSTM-based controller. The LSTM model is built and trained using the Keras and TensorFlow libraries in Python and tested in Simulink. The performance of the LSTM-based controller is evaluated under different case studies and compared to the conventional method of control. Simulation results demonstrate the effectiveness of this approach by outperforming the conventional controller and maintaining stability under different system parameter changes.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Godiva IV Burst Reproducibility and Diagnostic Testing

Godiva IV is a fast burst critical assembly located at the Nation Criticality Experiment Research Center (NCERC) in the Nevada National Security Site (NNSS). It is constructed of approximately 65 kg of highly enriched uranium (HEU) fuel alloyed with 1.5% molybdenum for strength. The assembly can be operated at delayed critical or can be used to perform super-prompt critical bursts with temperature rises of up to 250 °C. Several projects with the objective of characterizing Go diva IV are ongoing including characterizations of its radiation emission and thermomechanics. One of the characterization projects is a study of the variability in the relative source emission (or fluence in absolute terms) between bursts that are nominally the same size. There is some inherent variation in the number of fissions, or "size" of the burst, even for bursts where the operators perform identical processes. The source of the variation can be attributed to several factors. The largest contributor is the precision with which the operators are able to determine delayed critical (DC). Operators find DC for every burst operation. The impact of being slightly above or below DC can change the super-prompt critical reactivity and therefore the source term. The temperature of the fuel is another factor. Establishing delayed critical prior to performing a burst act as a control of the bulk temperature coefficient of reactivity.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

A Nonergodic Ground-Motion Model for the San Francisco Bay Area for Small-Magnitude Earthquakes

ABSTRACT Recently, generative models have become a computationally efficient alternative to physics-based numerical simulations of ground motions. Neural networks can learn from existing ground-motion data to generate unobserved ground-motion data at new source and site locations. A key challenge with generative models is ensuring that predicted ground motions remain within a physically realistic range. For this purpose, we developed an empirical, nonergodic ground-motion model (GMM) for small-magnitude earthquakes in the San Francisco Bay area based on about 5000 recordings per component for Mw ≤ 4 earthquakes. The nonergodic GMM predicts spatially varying median source, site, and path effects for both the Fourier amplitude spectrum (FAS) and the Fourier phase derivative (a proxy for duration), as well as the corresponding epistemic uncertainty for each term. For FAS, our model shows above-average source and site effects in the western part of the region and below-average effects in the eastern part, with regional effects exhibiting larger spatial correlation lengths with increasing frequency. For duration, the source term is negligible for small-magnitude earthquakes, and the site term leads to site-specific variations up to 5 s. Path effects for FAS and duration depend on the source–site pair and are extrapolated spatially using recent methods for path-effect modeling. The aleatory variability of the within-site within-path residuals is similar to the variability found in previous studies for other regions. The nonergodic model provides two key contributions: first, median adjustment terms that are transferable to larger magnitude earthquakes, further reducing aleatory variability in probabilistic seismic hazard analysis; second, region-specific criteria for validating machine learning-based ground-motion generators to evaluate whether synthetic ground motions exhibit physically realistic source, site, and path effects.

Lacour, Maxime↗

From Depletion to Restoration: Lessons From Long‐Term Monitoring of Carbon Gains and Losses in Cropping Systems

As global atmospheric CO 2 rapidly approaches a key tipping point, there is an urgent need to implement strategies to reverse this pattern. A generally accepted understanding of carbon (C) in agricultural fields includes: (H1) substantial C loss occurs when natural vegetation is converted to crops, (H2) soils typically reach a steady-state C concentration under contemporary practices, and (H3) improved management or crop selection can enhance soil C stocks over time. Significant variability exists, but studies consistently show large C losses from agricultural ecosystems, supporting H1. Although steady-state C levels (H2) are commonly assumed, measuring C gains or losses in mature agroecosystems is challenging. Efforts to increase soil C storage (H3) have limited data due to the diversity of potential practices, compounded by substantial variability in soil C measurements. Here, long-term (7–17 year) ecosystem C flux data from diverse cropping systems revealed that conventionally tilled annual row crops (maize and soybean) act as significant long-term atmospheric C sources, challenging H2. Furthermore, conservation tillage practices reduced C losses compared with conventional tillage but showed minimal evidence for long-term ecosystem C storage, even after 20+ years. This indicates that no-till practices reduce C losses but imply that no soil C is added, challenging H3. By contrast, perennial Miscanthus × giganteus, Panicum virgatum, and restored tallgrass prairie systems store C at the ecosystem scale more effectively than minimally tilled annual row crops. Analysis over multiple years demonstrates significant ecosystem C storage with perennial crops, varying by species, starting in the first year of transition. These findings, although focused on one region, suggest that the assumptions of steady-state C levels and increased storage from conservation practices do not universally apply and that significant changes to agroecosystems are required to increase C storage.

59 BASIC BIOLOGICAL SCIENCES↗

Quantifying Sources of Voltage Decay in Long-Term Durability Testing for PEM Water Electrolysis

Meeting a competitive 1$/kg hydrogen cost target for polymer electrolyte membrane water electrolysis (PEMWE) will require advances to significantly reduce capital costs and precious metal catalyst usage, while simultaneously enabling 40,000–80,000 h stack lifetimes under dynamic use conditions. Minimizing cell voltage decay rates is therefore a key goal for PEMWE, although the fundamental processes governing voltage decay are not yet well understood. Here we present a quantitative approach to analyze the contributions to voltage decay in long-term PEMWE testing using polarization curves, impedance spectroscopy, and post-mortem electron microscopy. We apply this approach to analyze a 28 μV h −1 decay rate observed in a 4000 h durability test of a cell using 0.5 mg cm −2 total PGM catalyst loading (0.4 mg Ir cm −2 anode, 0.1 mg Pt cm −2 cathode) and 3 A cm −2 current density. We also analyze a comparative series of 1000 h tests under different conditions. These results provide valuable insights into anode catalyst degradation processes, as well as transferrable methodology for PEMWE durability research.

08 HYDROGEN↗