Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SHINE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

Method for active sensor signal optimization

A system and method for optimizing a fiber optic sensor by properly clocking or rotationally orienting a window with a fiber optic focuser. This method may include shining light through the focuser into the window and receiving with a reflectometer a first reflection from a first surface of the window and a second reflection from a second surface of the window. Next, the method may include calculating a delta of intensities between the first and second reflections, and then rotating an orientation of the window to a next rotational orientation. The steps of rotating the orientation of the window, receiving reflections, and calculating their delta may be repeated any plurality of times to solve for a plurality of deltas. Then, the method may include the steps of determining which one of the deltas is the largest and fixing the window to the focuser at a rotational orientation associated therewith.

42 ENGINEERING↗

Humidity sensor

The present disclosure relates to a device that includes a light source, a detector; and a film having a first surface that includes a transition metal dichalcogenide, where the film is configured to interact with a volume of gas containing a concentration of water vapor, the light source is configured to shine a first light onto the first surface, the film is configured, as a result of the first light, to emit from the first surface a second light, the detector is configured to receive at least a portion of the second light, and the detector is configured to generate a signal proportional to an intensity of the second light.

Zhang, Hanyu↗

The Development of Energy-Recovery Linacs

Energy-recovery linacs (ERLs) have been emphasised by the recent (2020) update of the European Strategy for Particle Physics as one of the most promising technologies for the accelerator base of future high-energy physics. The current paper has been written as a base document to support and specify details of the recently published European roadmap for the development of energy-recovery linacs. The paper summarises the previous achievements on ERLs and the status of the field and its basic technology items. The main possible future contributions and applications of ERLs to particle and nuclear physics as well as industrial developments are presented. The paper includes a vision for the further future, beyond 2030, as well as a comparative data base for the main existing and forthcoming ERL facilities. A series of continuous innovations, such as on intense electron sources or high-quality superconducting cavity technology, will massively contribute to the development of accelerator physics at large. Industrial applications are potentially revolutionary and may carry the development of ERLs much further, establishing another shining example of the impact of particle physics on society and its technical foundation with a special view on sustaining nature.

43 PARTICLE ACCELERATORS↗

Low-frequency atomic electrometry

In a method of atomic electrometry, EIT spectroscopy is performed on host atoms of an alkali metal in a vapor cell. The EIT spectroscopy indicates a resonant energy of a probed Rydberg state of the host atoms. The vapor cell is exposed to an ambient electric field. A shift in the resonant energy as indicated by the EIT spectroscopy is observed and interpreted as a measurement of the ambient field. During the measurement of the ambient field, a bias electric field is generated inside the vapor cell by shining light into the vapor cell from a light source situated outside of the cell. The bias field is useful for increasing the sensitivity of the measurement.

Jau, Yuan-Yu↗

LIPSS status and LIPSS-2 future experiments.

The LIght Pseudoscalar and Scalar Search (LIPSS) experiment was the first dark matter experiment to use a photon beam from a high average power free-electron laser (FEL). LIPSS employed the "Light Shining through a Wall"(LSW)technique. Results from these laboratory dark matter searches established new boundaries for six possible dark matter particles. In addition, the LIPSS set-up can be modified for dark energy particle searches using the "Particles in a jar" technique. The LIPSS set-up will be summarized and a brief description of other DM/DE search possibilities (LIPSS-2) with the FEL facility will be discussed.

Boyce, James↗

Radiological Impact Assessment (RIA) following a postulated accident in PHWRS

Radiological Impact Assessment (RIA) following postulated accident i.e Loss of Coolant Accident (LOCA) with failed Emergency Core Cooling System (ECCS), performed as part of the reactor safety analysis of a typical 700 MWe Indian Pressurized Heavy Water Reactor(PHWR). The rationale behind the assessment is that the public needs to be protected in the event that the postulated accident results in radionuclide release outside containment. Radionuclides deliver dose to the human body through various pathways namely, plume submersion, exposure due to ground deposition, inhalation and ingestion. The total exposure dose measured in terms of total effective dose equivalent (TEDE) is the sum of doses to a hypothetical adult human at exclusion zone boundary by all the exposure pathways. The analysis provides the important inputs to decide upon the type of emergency counter measures to be adopted during the postulated accident. The importance of the various pathways in terms of contribution to the total effective dose equivalent(TEDE) is also assessed with respect to time of exposure. Inhalation and plume gamma dose are the major contributors towards TEDE during initial period of accident whereas ingestion and ground shine dose start dominating in TEDE in the extended period of exposure. Moreover, TEDE is initially dominated by I-131, Kr-88, Te-132, I-133 and Sr-89, whereas, as time progresses, Xe-133,I-131 and Te-132 become the main contributors. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

First Steps Toward a Quality of Climate Finance Scorecard (QUODA-CF): Creating a Comparative Index to Assess International Climate Finance Contributions

Are climate finance contributor countries, multilateral aid agencies and specialized funds using widely accepted best practices in foreign assistance? How is it possible to measure and compare international climate finance contributions when there are as yet no established metrics or agreed definitions of the quality of climate finance? As a subjective metric, quality can mean different things to different stakeholders, while of donor countries, recipients and institutional actors may place quality across a broad spectrum of objectives. This subjectivity makes the assessment of the quality of climate finance contributions a useful and necessary exercise, but one that has many challenges. This work seeks to enhance the development of common definitions and metrics of the quality of climate finance, to understand what we can about those areas where climate finance information is available and shine a light on the areas where there is a severe dearth of data. Allowing for comparisons of the use of best practices across funding institutions in the climate sector could begin a process of benchmarking performance, fostering learning across institutions and driving improvements when incorporated in internal evaluation protocols of those institutions. In the medium term, this kind of benchmarking and transparency could support fundraising in contributor countries and help build trust with recipient countries. As a feasibility study, this paper attempts to outline the importance of assessing international climate finance contributions while describing the difficulties in arriving at universally agreed measurements and indicators for assessment. In many cases, data are neither readily available nor complete, and there is no consensus on what should be included. A number of indicators are proposed in this study as a starting point with which to analyze voluntary contributions, but in some cases their methodologies are not complete, and further research is required for a robust measurement tool to be created.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Influence of pre-hydriding and quench on embrittlement of E110 alloy under LOCA conditions

The aims of present work were to investigate the corrosion behavior and residual ductility of pre-hydrided E110 alloy under LOCA conditions including the influence of cooling rate. The fragments of unirradiated and pre-hydrided cladding (9,5*8,33 mm with a 10 mm length) were used as samples. The claddings were made from an E110 sponge based alloy (finish polishing). The hydrogen concentration varied from 5 (as received) to 800 wppm. As a result of pre-hydriding δ- hydrides of zirconium have been formed into cladding material. Corrosion tests were carried out at temperatures 1100 and 1200 C. degrees in a steam (80 mg/s) and argon (25 ml/s) mixture flow. The samples were cooled by 2 regimes: the first one is cooling in the cold zone of test facility with rate about 20 C. degrees/s, the second is cooling in the cold zone of test facility with rate about 20 C. degrees/s from test temperature to 800 C. degrees and quench by dropping in to the water. The change of a sample mass was determined as a difference between initial sample mass and its mass after oxidation. The mechanical tests of oxidized claddings in a diametrical direction were carried out with the use of a universal tension testing machine at a steady deformation rate of 1 mm/min at 135 C. degrees. The investigations have established the following. The initial concentration of hydrogen has no effects on the oxidation kinetics, while the oxidation kinetics are parabolic and the breakaway oxidation is not observed. The oxide films on cladding surfaces are black and shining. There are no cracks, visual spots and peelings. The residual ductility of oxidized samples decreases with the increase of hydrogen concentration. The residual ductility of slow cooled claddings is higher than residual ductility of quenched claddings. The limiting value of ECR (Equivalent Cladding Reacted) corresponding to ductile-brittle transition as function of initial hydrogen content was evaluated. The value of residual ductility 2% was used as a ductile-brittle threshold. The limiting value of ECR for as-received E110 alloy is 18% and it decreases slowly to 15% with hydrogen content rising to 350 wppm. At hydrogen content of about 350 - 400 wppm there is a rapid change of limiting value of ECR from 15% to 8 %. At hydrogen content from 400 to 800 wppm the limiting value of ECR decreases from 8% to 3%. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Total Integrated Dose to Spent Fuel Pool Level Instrument Probes and Refueling Floor Personnel Dose Rates Meeting NRC Order EA-12-051 for a Typical Boiling Water Reactor - Paper 22

In reviewing the events after the March 11, 2011 Fukushima accident, the Nuclear Regulatory Commission (NRC) issued Order EA-12-051, Reference 1, requiring new reliable spent fuel pool (SFP) instrumentation for pool level determination under beyond design basis event conditions. In 2013, URS prepared a calculation for a typical Boiling Water Reactor to determine the Total Integrated Dose (TID) potentially to be imparted to radiation sensitive underwater probes (one primary and one backup) planned for meeting this Order. Additionally, URS calculated the radiological dose rates to an individual standing on the refueling floor for various SFP fill levels. NEI 12-02, Reference 2, defines the levels at which SFP condition identification is necessary as the following: Level 1 - level that is adequate to support operation of the normal fuel pool cooling system. Level 1 represents the higher of the following two points: - The level at which reliable suction loss occurs due to uncovering of the coolant inlet pipe, weir or vacuum breaker (depending on the design), or - The level at which the water height, assuming saturated conditions, above the centerline of the cooling pump suction provides the required net positive suction head specified by the pump manufacturer or engineering analysis. Level 2 - level that is adequate to provide substantial radiation shielding for a person standing on the spent fuel pool operating deck. Level 2 is based on either of the following: - 10 feet (+/- 1 foot) above the highest point of any fuel rack seated in the spent fuel pools, or - A designated level that provides adequate radiation shielding to maintain personnel radiological dose levels within acceptable limits while performing local operations in the vicinity of the pool. This level shall be based on either plant-specific or appropriate generic shielding calculations, considering the emergency conditions that may apply at the time and the scope of necessary local operations, including installation of portable SFP instrument channel components. Level 3 - level where fuel remains covered and actions to implement make-up water addition should no longer be deferred. Level 3 corresponds nominally (i.e. +/- 1 foot) to the highest point of any fuel rack seated in the spent fuel pool. The URS calculation did not define these levels or determine instrumentation setpoints. However, it determined refueling floor dose rates that could be used as a tool to determine the appropriate water depths for these levels. In determining the TID for the SFP probes and the radiological dose rates to the individual, the following radioactive sources were considered: 1. Spent Nuclear Fuel (SNF) stored in the spent fuel storage racks, 2. Local Power Range Monitors (LPRMs) stored above the top of the racks on hangers on the SFP walls 3. Radioactive material laden filters stored on platforms on top of the racks, and 4. Control Rod Blades (CRBs) stored above the top of the racks on hangers on the SFP walls. The TID for the SFP probes includes both the dose from normal operation (pool full of water) for the remaining plant life (an assumed 40 years, conservatively including an allowance for lifetime extension SFP loading) and, consistent with the NEI 12-02 guidelines, Reference 2, the assumed drop in elevation of the pool water level to the top of the spent fuel racks for a 6 hour period. The acceptable TID for the radiation-sensitive probe as defined by the manufacturer was 2x10{sup 9} rad. The individual on the pool deck was assumed to be standing on the edge of the pool with an unobstructed view of its contents, as a worst case scenario. Dose rates to this individual determined from direct shine from the same 4 sources were determined for SFP water levels varying from 1 ft above the SNF racks to 21 ft above the racks in one foot increments. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Catching Rays: How Bifacial_Radiance Sheds Light on the Future of Solar PV

The challenge of energy transition is immediate and immense, with current projections targeting 75 TW of photovoltaics (PV) capacity globally by 2050. Alongside the rapid deployment is the "solar-coaster" ride the PV industry experiences with evolving technologies and novel installation methods. In 2016, NREL developed bifacial_radiance, a python open-source modeling tool for bifacial PV. This tool is a wrapper of the raytracing engine Radiance, which you all know better than us at this workshop. Bifacial_radiance integrates the many characteristics of common PV systems to model irradiance on both the front and rear sides of bifacial PV technology - a technology that now represents 75% of utility-scale deployment in the US. Bifacial_radiance has been pivotal for understanding bifacial system performance, shading, and edge effects, and now agrivoltaics research. It has also helped develop simplified models used in PV due diligence tools for optimizing new deployments or evaluating the performance of existing projects. Now, it's the go-to comparison tool for many university, and industry-developed systems modeling tools, and a pivotal tool for further research in photovoltaics. This talk will cover the needs bifacial_radiance addresses as an open-source tool, its development path, and the opportunity for any raytracer to shine light on the solar industry through research and practical application of modeling in regular site installations and novel setups like agrivoltaics and vertical panels at high latitudes (and even the South Pole!).

agrivoltaics↗

Honoring Ken Nash: A Solution Chemistry Extraordinaire, Professor, Mentor, and my Friend

Back when I was a graduate student, Professor Nash told me, “The easy stuff is OK, but don’t be afraid to take on the hard research problems.” Since then, I have embraced this approach to research, and throughout the years, it has emboldened me to not shy away from, or give up on research projects with significant challenges. This is just one example of Ken’s influence on not only me, but the many graduate students who studied under his guidance. This presentation will survey some of the projects I have been involved in at Idaho National Laboratory since leaving Ken’s research group at Washington State University in 2011. It is my hope that his influence shines through.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

GammeV: results and future plans at Fermilab

GammeV is an axion-like particle photo regeneration experiment that employs the light shining through a wall technique. We obtain limits on the coupling of a photon to an axion-like particle that extend previous limits for both scalar and pseudoscalar particles in the milli-eV mass range. We have reconfigured our apparatus to search for chameleon particles. We describe the current results and future plans for similar activities at Fermilab.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The HITRAN2016 molecular spectroscopic database

This paper describes the contents of the 2016 edition of the HITRAN molecular spectroscopic compilation. The new edition replaces the previous HITRAN edition of 2012 and its updates during the intervening years. The HITRAN molecular absorption compilation is comprised of five major components: the traditional line-by-line spectroscopic parameters required for high-resolution radiative-transfer codes, infrared absorption cross-sections for molecules not yet amenable to representation in a line-by-line form, collision-induced absorption data, aerosol indices of refraction, and general tables such as partition sums that apply globally to the data. The new HITRAN is greatly extended in terms of accuracy, spectral coverage, additional absorption phenomena, added line-shape formalisms, and validity. Moreover, molecules, isotopologues, and perturbing gases have been added that address the issues of atmospheres beyond the Earth. Of considerable note, experimental IR cross-sections for almost 200 additional significant molecules have been added to the database.

Gordon, I. E.↗

In situ Preparation of HNbMoO{sub 6}/C Nanocomposite for Sensitive Detection of Clenbuterol

In this paper, we synthesized HNbMoO{sub 6}/C composite through the calcination of octylamine-intercalated HNbMoO{sub 6} precursor. The resulting HNbMoO{sub 6}/C composite showed some new phases of MoO{sub 2}, MoO{sub 3}, NbO{sub 2}, Nb{sub 2}O{sub 5}, and carbon, which was fully confirmed via powder X-ray diffraction (XRD), scanning electron microscopy (SEM), transmission electron microscopy (TEM), selected area electron diffraction (SAED), and X-ray photoelectron spectroscopy (XPS) technologies. Besides, the HNbMoO{sub 6}/C hybrid was coated on glass carbon electrode to construct an electrochemical sensor for sensitive determination of clenbuterol. The electrochemical behaviors of clenbuterol on the prepared electrode were tested by cyclic voltammetry (CV) and differential pulse voltammetry (DPV) analysis. The results showed that the intercalated carbon can act as active sites to accelerate electron transfer. In addition, more exposed surface areas of the HNbMoO{sub 6}/C composite will facilitate the electrolyte to permeate. The oxidation peak current of clenbuterol was linearly related to its concentration in the range of 1.04 × 10{sup −5} to 7.51 × 10{sup −4} mol L{sup −1}, and the determination limit was calculated to be 3.03 × 10{sup −6} mol L{sup −1} (S/N = 3). This sensor exhibits excellent stability, reproducibility, specificity, and good recoveries when applied to monitor clenbuterol in real samples.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗