Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SCINTILLATION COUNTER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

New Spin-Physics Experiments with Frozen-Spin Target at MAMI

In the physics program for the MAMI C accelerator the investigation of the spin dependent excitation spectrum of the nucleon and fundamental properties, such as the spin polarizabilities of the nucleon are an important goal. This will be tackled in the framework of the A2-collaboration by doing double polarization experiments, using the linearly or circularly polarized energy marked photon beam in combination with a new solid state polarized target. The horizontal dilution refrigerator of the Frozen Spin Target was constructed by and is operated in close cooperation with, the Joint Institute for Nuclear Research in Dubna, Russia. The system offers both longitudinally and transversely polarized protons and deuterons. The target material, butanol and deuterated butanol, was developed and produced by the Ruhr-University of Bochum and provides the highest degree of polarization, measured with a new NMR apparatus. The status of the experiment and preliminary results will be presented.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Validation of neutron emission profiles in MAST with a collimated neutron monitor

A neutron camera with liquid scintillator detectors is used in MAST to measure the neutron emissivity from D(d,n){sup 3}He reactions along collimated lines of sight. In this work, the measured recoil proton pulse height spectra generated in the detectors by the incident neutrons is modelled taking into account the energy spectrum of the generated neutrons, their spatial distribution and transport to the detectors as well as the detector's response function. The contribution of scattered neutrons to the pulse height spectrum is also modelled. Good agreement is found between the experimental data and the simulations. Examples are given showing the sensitivity of the recoil proton pulse height spectra to different observation angles with respect the neutral beam injection and the plasma rotation direction.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Near midplane scintillator-based fast ion loss detector on DIII-D

A new scintillator-based fast-ion loss detector (FILD) installed near the outer midplane of the plasma has been commissioned on DIII-D. This detector successfully measures coherent fast ion losses produced by fast-ion driven instabilities ({<=}500 kHz). Combined with the first FILD at {approx}45 Degree-Sign below the outer midplane [R. K. Fisher, et al., Rev. Sci. Instrum. 81, 10D307 (2010)], the two-detector system measures poloidal variation of losses. The phase space sensitivity of the new detector (gyroradius r{sub L}{approx}[1.5-8] cm and pitch angle {alpha}{approx}[35 Degree-Sign -85 Degree-Sign ]) is calibrated using neutral beam first orbit loss measurements. Since fast ion losses are localized poloidally, having two FILDs at different poloidal locations allows for the study of losses over a wider range of plasma shapes and types of loss orbits.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A pepper-pot emittance meter for low-energy heavy-ion beams

A novel emittance meter has been developed to measure the four-dimensional, transverse phase-space distribution of a low-energy ion beam using the pepper-pot technique. A characteristic feature of this instrument is that the pepper-pot plate, which has a linear array of holes in the vertical direction, is scanned horizontally through the ion beam. This has the advantage that the emittance can also be measured at locations along the beam line where the beam has a large horizontal divergence. A set of multi-channel plates, scintillation screen, and ccd camera is used as a position-sensitive ion detector allowing a large range of beam intensities that can be handled. This paper describes the design, construction, and operation of the instrument as well as the data analysis used to reconstruct the four-dimensional phase-space distribution of an ion beam. Measurements on a 15 keV He{sup +} beam are used as an example.

43 PARTICLE ACCELERATORS↗

Compact high-resolution gamma-ray computed tomography system for multiphase flow studies

In this paper, a compact high-resolution gamma-ray Computed Tomography (CompaCT) measurement system for multiphase flow studies and tomographic imaging of technical objects is presented. Its compact and robust design makes it particularly suitable for studies on industrial facilities and outdoor applications. Special care has been given to thermal ruggedness, shock resistance, and radiation protection. Main components of the system are a collimated {sup 137}Cs isotopic source, a thermally stabilised modular high-resolution gamma-ray detector arc with 112 scintillation detector elements, and a transportable rotary unit. The CompaCT allows full CT scans of objects with a diameter of up to 130 mm and can be operated with any tilting angle from 0 Degree-Sign (horizontal) to 90 Degree-Sign (vertical).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The new bern PET cyclotron, its research beam line, and the development of an innovative beam monitor detector

The new Bern cyclotron laboratory aims at industrial radioisotope production for PET diagnostics and multidisciplinary research by means of a specifically conceived beam transfer line, terminated in a separate bunker. In this framework, an innovative beam monitor detector based on doped silica and optical fibres has been designed, constructed, and tested. Scintillation light produced by Ce and Sb doped silica fibres moving across the beam is measured, giving information on beam position, shape, and intensity. The doped fibres are coupled to commercial optical fibres, allowing the read-out of the signal far away from the radiation source. This general-purpose device can be easily adapted for any accelerator used in medical applications and is suitable either for low currents used in hadrontherapy or for currents up to a few {mu}A for radioisotope production, as well as for both pulsed and continuous beams.

43 PARTICLE ACCELERATORS↗

High current H{sub 2}{sup +} cyclotrons for neutrino physics: The IsoDAR and DAE{delta}ALUS projects

Using H{sub 2}{sup +} ions is expected to mitigate the two major impediments to accelerating very high currents in cyclotrons, due to lower space charge at injection, and stripping extraction. Planning for peak currents of 10 particle milliamps at 800 MeV/amu, these cyclotrons can generate adequate neutrino fluxes for Decay-At-Rest (DAR) studies of neutrino oscillation and CP violation. The Injector Cyclotron, at 60 MeV/amu can also provide adequate fluxes of electron antineutrinos from {sup 8}Li decay for sterile neutrino searches in existing liquid scintillator detectors at Kam LAND or SNO+. This paper outlines programs for designing and building these machines.

43 PARTICLE ACCELERATORS↗

Distance calculation methods used in linearization for particle identification in multi-detector arrays

Interest in the influence of the neutron-to-proton (N/Z) degree of freedom on multi-fragmentation has demanded an improvement in the capabilities of multidetector arrays as well as the particle identification methods. Excellent isotopic identification of particles through a linearization analysis is achieved with various algorithms for calculating the distance between a point and a polynomial function. A new Point-to-Curve method of distance determination is introduced. Descriptions of various methods as well as their performances are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

From nGy to MGy - New dosimetry with LiF:Mg,Cu,P thermoluminescence detectors

One of the well known advantages of thermoluminescence (TL) detectors made of lithium fluoride doped with magnesium, copper and phosphorus (LiF:Mg,Cu,P) is their very high sensitivity to ionizing radiation. LiF:Mg,Cu,P detectors enable measurements of radiation doses from tens of nanograys up to a few kilograys, when the total saturation of the signal of the so-called main dosimetric peak occurs. Only recently, unprecedented high-temperature emission of LiF detectors heated to temperatures up to 600 Degree-Sign C, was observed after exposures to radiation doses ranging from 1 kGy to 1 MGy. For quantification of the glow-curve shape changes of LiF:Mg,Cu,P detectors in this range of doses and determination of the absorbed dose, the Ultra-High Temperature Ratio coefficient (UHTR) was defined. This newly established dosimetric method was tested in a range of radiation qualities, such as gamma radiation, electron and proton beams, thermal neutron fields and high-energy mixed fields around the SPS and PS accelerators at CERN. The new method for ultra-high dose range monitoring with a single LiF:Mg,Cu,P detector, which is capable of covering at least twelve orders of magnitude of doses, can be used for dosimetry at high energy accelerators, thermonuclear fusion technology facilities and has great potential for accident dosimetry in particular. A number of dosimetric sets with LiF:Mg,Cu,P detectors are currently installed around the LHC at CERN.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Hard x-ray tomographic studies of the destruction of an energetic electron ring

A tomography system was designed and built at the Large Plasma Device to measure the spatial distribution of hard x-ray (100 KeV-3 MeV) emissivity. The x-rays were generated when a hot electron ring was significantly disrupted by a shear Alfven wave. The plasma is pulsed at 1 Hz (1 shot/s). A lead shielded scintillator detector with an acceptance angle defined by a lead pinhole is mounted on a rotary gimbal and used to detect the x-rays. The system measures one chord per plasma shot using only one detector. A data plane usually consists of several hundred chords. A novel Dot by Dot Reconstruction (DDR) method is introduced to calculate the emissivity profile from the line integrated data. In the experiments, there are often physical obstructions, which make measurements at certain angles impossible. The DDR method works well even in this situation. The method was tested with simulated data, and was found to be more effective than previously published methods for the specific geometry of this experiment. The reconstructed x-ray emissivity from experimental data by this method is shown.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of a fast scintillator based beam phase measurement system for compact superconducting cyclotrons

In an isochronous cyclotron, measurements of central phase of the ion beam with respect to rf and the phase width provide a way to tune the cyclotron for maximum energy gain per turn and efficient extraction. We report here the development of a phase measurement system and the measurements carried out at the Variable Energy Cyclotron Centre's (VECC's) K= 500 superconducting cyclotron. The technique comprises detecting prompt {gamma}-rays resulting from the interaction of cyclotron ion beam with an aluminium target mounted on a radial probe in coincidence with cyclotron rf. An assembly comprising a fast scintillator and a liquid light-guide inserted inside the cyclotron was used to detect the {gamma}-rays and to transfer the light signal outside the cyclotron where a matching photo-multiplier tube was used for light to electrical signal conversion. The typical beam intensity for this measurement was a few times 10{sup 11} pps.

43 PARTICLE ACCELERATORS↗

Photon-induced positron annihilation lifetime spectroscopy using ultrashort laser-Compton-scattered gamma-ray pulses

High-energy ultrashort gamma-ray pulses can be generated via laser Compton scattering with 90 Degree-Sign collisions at the UVSOR-II electron storage ring. As an applied study of ultrashort gamma-ray pulses, a new photon-induced positron annihilation lifetime spectroscopy approach has been developed. Ultrashort gamma-ray pulses with a maximum energy of 6.6 MeV and pulse width of 2.2 ps created positrons throughout bulk lead via pair production. Annihilation gamma rays were detected by a BaF{sub 2} scintillator mounted on a photomultiplier tube. A positron lifetime spectrum was obtained by measuring the time difference between the RF frequency of the electron storage ring and the detection time of the annihilation gamma rays. We calculated the response of the BaF{sub 2} scintillator and the time jitter caused by the variation in the total path length of the ultrashort gamma-ray pulses, annihilation gamma rays, and scintillation light using a Monte Carlo simulation code. The positron lifetime for bulk lead was successfully measured.

36 MATERIALS SCIENCE↗

Neutron spectrometry using LNL bonner spheres and FLUKA

The characterization of neutron fields has been made with a system based on a scintillation detector and multiple moderating spheres. The system, together with the unfolding procedure, have been tested in quasi-monochromatic neutron energy fields and in complex, mixed, cyclotron based environments. FLUKA simulations have been used to produce response functions and reference energy spectra.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

An in situ accelerator-based diagnostic for plasma-material interactions science on magnetic fusion devices

This paper presents a novel particle accelerator-based diagnostic that nondestructively measures the evolution of material surface compositions inside magnetic fusion devices. The diagnostic's purpose is to contribute to an integrated understanding of plasma-material interactions in magnetic fusion, which is severely hindered by a dearth of in situ material surface diagnosis. The diagnostic aims to remotely generate isotopic concentration maps on a plasma shot-to-shot timescale that cover a large fraction of the plasma-facing surface inside of a magnetic fusion device without the need for vacuum breaks or physical access to the material surfaces. Our instrument uses a compact (∼1 m), high-current (∼1 milliamp) radio-frequency quadrupole accelerator to inject 0.9 MeV deuterons into the Alcator C-Mod tokamak at MIT. We control the tokamak magnetic fields – in between plasma shots – to steer the deuterons to material surfaces where the deuterons cause high-Q nuclear reactions with low-Z isotopes ∼5 μm into the material. The induced neutrons and gamma rays are measured with scintillation detectors; energy spectra analysis provides quantitative reconstruction of surface compositions. An overview of the diagnostic technique, known as accelerator-based in situ materials surveillance (AIMS), and the first AIMS diagnostic on the Alcator C-Mod tokamak is given. Experimental validation is shown to demonstrate that an optimized deuteron beam is injected into the tokamak, that low-Z isotopes such as deuterium and boron can be quantified on the material surfaces, and that magnetic steering provides access to different measurement locations. The first AIMS analysis, which measures the relative change in deuterium at a single surface location at the end of the Alcator C-Mod FY2012 plasma campaign, is also presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Extreme ultra-violet movie camera for imaging microsecond time scale magnetic reconnection

An ultra-fast extreme ultra-violet (EUV) movie camera has been developed for imaging magnetic reconnection in the Caltech spheromak/astrophysical jet experiment. The camera consists of a broadband Mo:Si multilayer mirror, a fast decaying YAG:Ce scintillator, a visible light block, and a high-speed visible light CCD camera. The camera can capture EUV images as fast as 3.3 × 10{sup 6} frames per second with 0.5 cm spatial resolution. The spectral range is from 20 eV to 60 eV. EUV images reveal strong, transient, highly localized bursts of EUV radiation when magnetic reconnection occurs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Segmented scintillation detectors with silicon photomultiplier readout for measuring antiproton annihilations

The Atomic Spectroscopy and Collisions Using Slow Antiprotons experiment at the Antiproton Decelerator (AD) facility of CERN constructed segmented scintillators to detect and track the charged pions which emerge from antiproton annihilations in a future superconducting radiofrequency Paul trap for antiprotons. A system of 541 cast and extruded scintillator bars were arranged in 11 detector modules which provided a spatial resolution of 17 mm. Green wavelength-shifting fibers were embedded in the scintillators, and read out by silicon photomultipliers which had a sensitive area of 1 × 1 mm{sup 2}. The photoelectron yields of various scintillator configurations were measured using a negative pion beam of momentum p ≈ 1 GeV/c. Various fibers and silicon photomultipliers, fiber end terminations, and couplings between the fibers and scintillators were compared. The detectors were also tested using the antiproton beam of the AD. Nonlinear effects due to the saturation of the silicon photomultiplier were seen at high annihilation rates of the antiprotons.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A fast microchannel plate-scintillator detector for velocity map imaging and imaging mass spectrometry

The time resolution achievable using standard position-sensitive ion detectors, consisting of a chevron pair of microchannel plates coupled to a phosphor screen, is primarily limited by the emission lifetime of the phosphor, around 70 ns for the most commonly used P47 phosphor. We demonstrate that poly-para-phenylene laser dyes may be employed extremely effectively as scintillators, exhibiting higher brightness and much shorter decay lifetimes than P47. We provide an extensive characterisation of the properties of such scintillators, with a particular emphasis on applications in velocity-map imaging and microscope-mode imaging mass spectrometry. The most promising of the new scintillators exhibits an electron-to-photon conversion efficiency double that of P47, with an emission lifetime an order of magnitude shorter. The new scintillator screens are vacuum stable and show no signs of signal degradation even over longer periods of operation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗