SU-F-T-73: Experimental Determination of the Effective Point of Measurement in Electron Beams Using a Commercial Scintillation Detector

Purpose: The aim of this work was to determine experimentally the effective point of measurement (EPOM) in clinical electron beams for three cylindrical ionization chambers using a commercial scintillation detector as a reference detector. Methods: Percent depth dose (PDD) curves were measured using an Exradin W1 scintillation detector and were used as a representative PDD to water. Depth dose curves were measured with the Exradin A18, A1SL, and A28 ionization chambers. The raw ionization chamber curve data were corrected by the chamber fluence perturbation correction factor and restricted mass collisional stopping power ratio at each depth to obtain a percent depth dose curve to the gas volume (PDDGV) of the detector. Ratios of the W1 PDD to the ion chamber PDDGV were calculated for each measurement depth. The W1 PDD curve was shifted by small depth increments, Δz, until the ratio of the W1 PDD to the ion chamber PDDGV was depth-independent (optimal Δz). A MATLAB routine was developed to determine the optimal Δz value. Results: The optimal Δz shift was used as an estimate of the EPOM for each chamber. The average calculated EPOM shifts (expressed as a fraction of the chamber cavity radius) for the A18, A1SL, and A28 ionization chambers were 0.21 ± 0.04, 0.10 ± 0.05, and 0.22 ± 0.03, respectively. Conclusion: The experimentally determined EPOM values for the A18 and A1SL in this work agreed with the simulated values of Muir and Rogers (MedPhys 2014). The results also indicate that the Exradin W1 scintillator is water equivalent for electron energies of 6 MeV, 9 MeV, 12 MeV, and 16 MeV. In addition, we confirmed that the AAPM TG51 recommended EPOM shift of 0.5 times the cavity radius is not accurate for the A18 and A1SL chambers.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Scintillation counters in modern high-energy physics experiments (Review)

Scintillation counters (SCs) based on organic plastic scintillators (OPSs) are widely used in modern high-energy physics (HEP) experiments. A comprehensive review is given to technologies for production of OPS strips and tiles (extrusion, injection molding, etc.), optical and physical characteristics of OPSs, and methods of light collection based on the use of wavelength-shifting (WLS) fibers coupled to multipixel vacuum and silicon PMs. Examples are given of the use of SCs in modern experiments involved in the search for quarks and new particles, including the Higgs boson (D0, CDF, ATLAS, CMS), new states of matter (ALICE), CP violation (LHCb, KLOE), neutrino oscillations (MINOS, OPERA), and cosmic particles in a wide mass and energy interval (AMS-02). Scintillation counters hold great promise for future HEP experiments (at the ILC, NICA, FAIR) due to properties of a high segmentation, WLS fiber light collection, and multipixel silicon PMT readout.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Scintillation detector with SiPM matrix as a photosensor

The results of a characterization study of the scintillation detector with SiPM matrices as multichannel photosensors are presented. The SiPM matrix attached to a plastic scintillator gives a snapshot of the glowing track of a charged particle traversing the scintillator.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Comparative testing of various flow-cell detectors fabricated using CaF{sub 2} solid scintillator

A monitoring system based on a flow-cell detector was developed for measuring the tritium concentration in water. The flow-cell detector was fabricated using a granular CaF{sub 2} solid scintillator. This system does not use a liquid scintillation counting system and does not generate radioactive organic liquid waste. Moreover, continuous real-time measurements are possible, in contrast to a liquid scintillation counting system, which requires batch measurements. For further development of the system, four flow-cell detectors were fabricated. They included a single 3-mm-diameter cell, three 3-mm-diameter cells in series, a single 5-mm-diameter cell, and three 5-mm-diameter cells in series. Continuously flowing water containing tritium at various concentrations was passed through the flow cells, and tritium count were measured for 600 and 10000 s. Investigating the relation between the count rate and concentration, the three 5-mm-diameter cells were most sensitive, with a linear relation maintained down to approximately 2 Bq/ml and 10 Bq/ml for 10000- and 600-s measurements, respectively. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Quality of a 28 cm Long LYSO Crystal and Progress on Optical and Scintillation Properties

Because of their high stopping power and fast and bright scintillation, cerium doped LSO and LYSO crystals have attracted a broad interest in the physics community pursuing precision electromagnetic calorimeter for future high energy physics experiments. Their excellent radiation hardness against γ-rays, neutrons and charged hadrons also makes them a preferred material for calorimeters to be operated in a severe radiation environment, such as the HL-LHC. An effort was made at SIPAT to grow 25 X 0 (28 cm) long LYSO crystals for high energy physics applications. In this paper, the optical and scintillation properties and its radiation hardness against γ-ray irradiations up to 1 Mrad are presented for the first 2.5 X 2.5 X 28 cm LYSO sample. An absorption band was found at the seed end of this sample and three other 20 cm long samples, which was traced back to a bad seed crystal used in the corresponding crystal growth process. Significant progresses in optical and scintillation properties were achieved for large size LYSO crystals after eliminating this absorption band.

47 OTHER INSTRUMENTATION↗

Design and Prototyping of a High Granularity Scintillator Calorimeter

A novel approach for constructing fine-granularity scintillator calorimeters, based on the concept of an Integrated Readout Layer (IRL) was developed. The IRL consists of a printed circuit board inside the detector which supports the directly-coupled scintillator tiles, connects to the surface-mount SiPMs and carries the necessary front-end electronics and signal/bias traces. Prototype IRLs using this concept were designed, prototyped and successfully exposed to test beams. Concepts and implementations of an IRL carried out with funds associated with this contract promise to result in the next generation of scintillator calorimeters.

Direct coupling↗

Ionospheric S4 Scintillations From GNSS Radio Occultation (RO) at Slant Path

Ionospheric scintillation can significantly degrade the performance and the usability of space‐based communication and navigation signals. Characterization and prediction of ionospheric scintillation can be made from the Global Navigation Satellite System (GNSS) radio occultation (RO) technique using the measurement from a deep slant path where the RO tangent height (ht) is far below the ionospheric sources. In this study, the L–band S4 from the RO measurements at ht = 30 km is used to infer the amplitude scintillation on the ground. The analysis of global RO data at ht = 30 km shows that sporadic–E (Es), equatorial plasma bubbles (EPBs), and equatorial spread–F (ESF) produce most of the significant S4 enhancements, although the polar S4 is generally weak. The enhanced S4 is a strong function of local time and magnetic dip angle. The Es–induced daytime S4 tends to have a negative correlation with the solar cycle at low latitudes but a positive correlation at high latitudes. The nighttime S4 is dominated by a strong semiannual variation at low latitudes.

GPS radio occultation↗

Linearity for Ca2+-Doped CeBr3 Scintillating Materials

The Remote Sensing Laboratory (RSL) developed an aliovalently calcium-doped cerium tribromide (CeBr3:Ca2+) crystal with 3.2% resolution. RSL completed a crystal assessment, and Sandia National Laboratories calculated the predictive performance and physical characteristics using proven density functional theory (DFT) formalism. Results are reported for the work done to map the detector performance, characteristics, calcium doping concentration, and crystal strength. Preliminary scintillation measurements for this aliovalently calcium-doped CeBr3 scintillator exhibit a slight blue shift in fluorescence emission at 371 nm excitation for CeBr3. The structural, electronic, and optical properties of CeBr3 crystals were investigated using DFT within generalized gradient approximation. The calculated lattice parameters are in good agreement with the experimental data. The energy band structures and density of states were obtained. The optical properties of CeBr3, including the dielectric function, were calculated. Specifically, we report excellent linearity with the aliovalently calcium-doped CeBr3 crystal. Proportionality of light yield is one area of performance in which Ce-doped and Ce-based lanthanide halides excel. Maintaining proportionality is key to producing a strong, high-performance scintillator. Relative light yield proportionality was measured for both doped and undoped samples of CeBr3 to ensure no loss in performance was incurred during doping. The light output and proportionality, however, appear to be similar to CeBr3. There was a reduced yield at low energy. Relative light yield proportionality measurements suggest that dopants do not significantly affect proportionality at higher energies. RSL completed additional testing and evaluation of the new crystal and assessed benchmark spectroscopy measurements. Results, which present energy resolution as a function of energy, are summarized. Typical spectroscopy results using a 137Cs radiation source are shown for our crystallite. We obtain 4.5% for the packaged crystallite. More spectra are presented for 241Am, 60Co, 228Th, and background to exemplify CeBr3:Ca2+ over a broader energy range.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Linearity for Ca2+-Doped CeBr3 Scintillating Materials

The National Security Technologies, LLC, Remote Sensing Laboratory (RSL) developed an aliovalently calcium-doped cerium tribromide (CeBr3:Ca2+) crystal with a FWHM resolution of 3.2% at the 137Cs 662 keV gamma energy. RSL completed a crystal assessment and Sandia National Laboratories calculated the predictive performance and physical characteristics using proven density functional theory (DFT) formalism. Results are reported for the work done to map the detector performance, characteristics, calcium doping concentration, and crystal strength. Preliminary scintillation measurements for this aliovalently calcium-doped CeBr3 scintillator exhibit a slight blue shift in fluorescence emission at 371 nm excitation for CeBr3. The structural, electronic, and optical properties of CeBr3 crystals were investigated using the DFT within generalized gradient approximation. The calculated lattice parameters are in good agreement with the experimental data. The energy band structures and density of states were obtained. The optical properties of CeBr3, including the dielectric function of photons per unit energy, were calculated. Specifically, we report excellent linearity with the aliovalent CeBr3:Ca2+ crystal. Proportionality of light yield is one area of performance in which Ce-doped and Ce-based lanthanide halides excel. Maintaining proportionality is the key to producing a strong, high-performance scintillator. Relative light yield proportionality was measured for both doped and undoped samples of CeBr3 to ensure no loss in performance was incurred by doping. The light output and proportionality, however, appear to be similar to CeBr3. There was a reduced yield at low energy. Relative light yield proportionality measurements suggest that dopants do not significantly affect proportionality at higher energies. RSL completed additional testing and evaluation of the new crystal as well as the assessment of benchmarking spectroscopy. Results, which present energy resolution as a function of energy, are summarized. Typical spectroscopy results using a 137Cs radiation source are shown for our crystallites with diameters <1 cm. We obtain 3.2% before packing the crystallite in a sealed detector container and 4.5% for the packaged crystallite. More spectra were obtained for 241Am, 60Co, 228Th, and background to exemplify CeBr3:Ca2+ over a broader energy range.

aliovalent substitution↗

An apparatus and method for directly measuring the depth-dependent gain and spatial resolution of turbid scintillators

Turbid (powder or columnar–structured) scintillators are widely used in indirect flat panel detectors (I–FPDs) for scientific, industrial, and medical radiography. Light diffusion and absorption within these scintillators is expected to cause depth–dependent variations in their x ray conversion gain and spatial blur. Furthermore, these variations degrade the detective quantum efficiency of I–FPDs at all spatial frequencies. Despite their importance, there are currently no established methods for directly measuring scintillator depth effects. This work develops the instrumentation and methods to achieve this capability.

47 OTHER INSTRUMENTATION↗

Light output and neutron detection efficiency of boron-based neutron scintillator screens for neutron imaging

Recent research has explored the development of boron-based neutron scintillator screens, which potentially offer improved spatial resolution and neutron capture efficiency compared to traditional lithium-based screens. This work builds upon previous efforts to improve boron-based neutron scintillators by assessing a newer generation of boron-based scintillator screens fabricated using different compositions and fabrication approaches compared to previous generations of screens. Some of the test screens exhibit higher light output than previous efforts and higher neutron capture efficiency than lithium-based screens. This paper describes the current state of screen development, measurement results for the most recent generation of screens, and future activities.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Investigating new activators for small-bandgap LaX 3 (X = Br, I) scintillators

In this study, luminescence and scintillation properties of Bi 3+ , Sb 3+ , and Eu 2+ -doped LaI 3 and LaBr 3 were explored. Out of the three dopants investigated, Eu 2+ was the most promising new activator for small-bandgap LaX 3 (X = Br, I) and was further studied in the mixed-halide LaBr 3-x I x . Crystals were grown from the melt using the vertical Bridgman method. LaBr 3 :Eu 2+ 0.5% (mol) had the most favorable scintillation properties with a light output of 43,000 ph/MeV and 6% energy resolution at 662 keV. Performance of LaBr 3-x I x :Eu 2+ worsened for most samples as iodide concentration was increased. Finally, room-temperature scintillation of LaI 3 :Eu 2+ 0.1% and 0.5% was observed and is the first case of room-temperature emission reported for doped LaI 3 .

36 MATERIALS SCIENCE↗

Observations regarding inclusions in the growth of $\mathrm{Cs}$ 2 $\mathrm{HfCl}$ 6 single crystal scintillators

Cs 2 HfCl 6 (CHC) is a promising high density, high-Z, non-hygroscopic, and high energy resolution scintillator. In CHC, many crystals have CsCl inclusions that form during growth. In this paper, we investigate how material synthesis, growth rate, and thermal gradient affect the formation of CsCl inclusions and their effect on scintillation performance. First, precursor material was made through a methanol synthesis process both with and without hydrochlorination. Next, five crystals were grown using Bridgman method, at growth rates of 1 or 0.5 mm/h, and thermal gradients of 21 °C or 34 °C per millimeter. The best overall performance was observed in a 22 mm diameter crystal produced using hydrochlorination which was grown at 1 mm/h in a thermal gradient of 34 °C per millimeter. It had a light yield of 36,000 photons/MeV and an energy resolution of 4.0% at 662 keV. Finally, we have also shown that poorer scintillation performance in the lower quality crystals is most likely due to reduced light collection caused by a higher concentration of inclusions.

36 MATERIALS SCIENCE↗

Crystal growth of new high light yield halide perovskite scintillator RbSrI 3

X-ray radiography systems are a key national security technology enabling non-invasive cargo screening. However, the scintillators currently used in these systems have limitations in performance that prompt research for new suitable materials. Here, in this work, crystal growth, physical properties, and optical and scintillation properties of a new halide perovskite scintillator RbSrI 3 were investigated for the first time. The melting point was determined to be 453 °C. Divalent europium and ytterbium were investigated as potential luminescent activators. Light yield and energy resolution of RbSrI 3 :Eu 5 mol% was 78,700 ph/MeV and 2.8 % at 662 keV, and that of RbSrI 3 :Yb 0.5 mol% was 24,000 ph/MeV and 4.9 % at 662 keV.

36 MATERIALS SCIENCE↗

Growth and luminescent properties of scintillators based on the single crystalline films of Lu{sub 3−x}Gd{sub x}Al{sub 5}O{sub 12}:Ce garnet

Highlights: • Single crystalline films of Lu{sub 3−x}Gd{sub x}Al{sub 5}O{sub 12} garnets at x = 0 ÷ 3.0 were grown by LPE method onto YAG substrates. • Lattice constant of Lu{sub 3−}Gd{sub x}Al{sub 5}O{sub 12}:Ce film and the misfit m between films and YAG substrate changed linearly with increasing of Gd content. • Effective Gd{sup 3+}–Ce{sup 3+} energy transfer occurs in the Lu{sub 3−x}Gd{sub x}Al{sub 5}O{sub 12}:Ce films. • Best scintillation light yield is observed in the Lu{sub 3}Al{sub 5}O{sub 12}:Ce and Lu{sub 2.4}Gd{sub 0.6}Al{sub 5}O{sub 12}:Ce films. • Increase of the Gd content in x = 1.5–2.5 range results in decreasing the scintillation LY of Lu{sub 3−x}Gd{sub x}Al{sub 5}O{sub 12}:Ce films. - Abstract: The work is related to the growth of scintillators based on the single crystalline films (SCF) of Ce{sup 3+} doped Lu{sub 3−}Gd{sub x}Al{sub 5}O{sub 12} mixed rare-earth garnets by Liquid Phase Epitaxy (LPE) method. We have shown, that full set of Lu{sub 3−}Gd{sub x}Al{sub 5}O{sub 12} SCFs with x values ranging from 0 to 3.0 can be successfully crystallized by the LPE method onto Y{sub 3}Al{sub 5}O{sub 12} (YAG) substrates from the melt-solutions based on PbO-B{sub 2}O{sub 3} flux. The absorption, X-ray excited luminescence, photoluminescence, thermoluminescence and light yield measurements, the latter under excitation by α-particles of {sup 239}Pu and {sup 241}Am radioisotopes, were applied for their characterization.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Optical and scintillation properties of ScAlMgO{sub 4} crystal grown by the floating zone method

Highlights: • ScAlMgO4 single crystal is synthesized by the floating zone method. • Optical and scintillation properties of the crystal are studied. • The band gap is observed around 200 nm which is consistent with the theoretical work. • The emission appears around 400 nm in photoluminescence and scintillation. - Abstract: The undoped ScAlMgO{sub 4} crystal was synthesized by the Floating Zone (FZ) method, and we evaluated the optical and scintillation properties. The transmittance spectrum showed the absorption edge around 200 nm. VUV-excited emission/excitation spectrum was characterized at a synchrotron facility (UVSOR). Our experiment revealed that the emission was around 400 nm by 200 nm excitation, and the excitation band was 170–210 nm for the latter emission peak. The decay time characterized by 280 nm excitation was 8.3 and 43 ns. Under X-ray irradiation, an emission was observed around 400 nm as for VUV excitation, and the latter decay time constants were 0.23 and 2.2 μs. In addition, the afterglow level at 20 ms after X-ray irradiation was around 0.1% of the intensity during irradiation.

36 MATERIALS SCIENCE↗

Performance of the first prototype of the CALICE scintillator strip electromagnetic calorimeter

A first prototype of a scintillator strip-based electromagnetic calorimeter was built, consisting of 26 layers of tungsten absorber plates interleaved with planes of 45 × 10 × 3 mm³ plastic scintillator strips. Data were collected using a positron test beam at DESY with momenta between 1 and 6 GeV/c. The prototype's performance is presented in terms of the linearity and resolution of the energy measurement. These results represent an important milestone in the development of highly granular calorimeters using scintillator strip technology. A number of possible design improvements were identified, which should be implemented in a future detector of this type. This technology is being developed for a future linear collider experiment, aiming at the precise measurement of jet energies using particle flow techniques.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Cross-correlation measurements with the EJ-299-33 plastic scintillator

New organic–plastic scintillation compositions have demonstrated pulse-shape discrimination (PSD) of neutrons and gamma rays. We present cross-correlation measurements of 252 Cf and mixed uranium–plutonium oxide (MOX) with the EJ-299-33 plastic scintillator. For comparison, equivalent measurements were performed with an EJ-309 liquid scintillator. Offline, digital PSD was applied to each detector. These measurements show that EJ-299-33 sacrifices a factor of 5 in neutron–neutron efficiency relative to EJ-309, but could still utilize the difference in neutron–neutron efficiency and neutron single-to-double ratio to distinguish 252 Cf from MOX. These measurements were modeled with MCNPX-PoliMi, and MPPost was used to convert the detailed collision history into simulated cross-correlation distributions. MCNPX-PoliMi predicted the measured 252 Cf cross-correlation distribution for EJ-309 to within 10%. Greater photon uncertainty in the MOX sample led to larger discrepancy in the simulated MOX cross-correlation distribution. In conclusion, the modeled EJ-299-33 plastic also gives reasonable agreement with measured cross-correlation distributions, although the MCNPX-PoliMi model appears to under-predict the neutron detection efficiency.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗