Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Robot”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

Robotic NDA of Holdup Deposits in Gaseous Diffusion Piping by Gamma Assay of Uranium-235 - 18331

This research exploits in-pipe access to develop robotically deployed, high-cadence, accurate, certain, paperless assay of U-235 in holdup deposits within process piping. Prior radiometric assay from outside the pipes suffered from manual deployment challenges, attenuation of detection through pipe walls, long counting times, approximate modeling, and shortfalls associated with transcription and human interpretation. These downsides limited the speed, quality, and economy of assay resulting in vast cost and budget consequences to D and D. D and D of outdated facilities cuts into these pipes as part of the demolition process, creating the unique, previously unexploited possibility of robotic in-pipe assay. The assay collimates radiation emanating from all but a short segment of pipe wall from reaching a gamma detector. Hence, the detector only views and measures source from a short segment of pipe at a given time. This is achieved by an innovative pair of collimating discs that are coaxial with the pipe and positioned fore and aft of the detector. The detector assembly is translated through pipes by an autonomous mobile robot. Beyond radiometric assay of U-235, the robot images and geometrically models the pipe interior and deposit appearance. The robot is recovered from the same pipe opening from which it is launched, hence it drives the same distance out and back, measuring the same deposits twice. This achieves redundant radiometric and odometric measurements which adds further to statistical significance of the method. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

The Design and Performance of Low Cost Haptic Interfaces to Control Precision Nuclear Robotic System - 18351

Nuclear decommissioning environments are challenging and hazardous, typically involving high temperatures, pressures and extreme radiation. Robotic devices are commonly used to complete tasks within challenging environments, which would otherwise pose a risk to human health, however remotely operating robots without full three-dimensional vision is challenging, and operators of robotic systems require extensive training to enable precise navigation through three-dimensional environments using multiple two-dimensional views for feedback. This project explores the possibility of using a human arm as a master device for controlling a variety of low-cost slave robots, with the aim of reducing training times whilst providing a cheaper, more intuitive control system. Virtual Reality (VR) and haptics are used as an aid for navigation of the remote environment, whilst also providing a digital twin for the operator to enable real-time feedback from the slave robot. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A Prototype Dual Robot System to Perform Ultrasonic and Visual Inspection for the Bottom of Double-Shell Tanks - 18624

Up to this point, ultrasonic inspection-based condition data has only been available for double-shell tank (DST) sidewalls because direct inspection access to the primary tank bottom is limited to vent duct channels in an insulating refractory pad that the primary tank rests on. Probe access through the air slot would provide the opportunity to get information about the condition of the bottom of the primary tank, but it is a challenge to deploy a crawling robot that is capable of performing nondestructive ultrasonic and visual inspection through confined air slots. As such, a conceptual prototype of a deployable inspection robot system to enable ultrasonic and visual inspection for DST base through ventilation ducts was designed and fabricated. This prototype dual robot system consisting of the AnnulusBot and the MouseBot can be integrated with nondestructive evaluation (NDE) sensors to inspect and examine the physical properties of the underside of DSTs to enable status assessment. The AnnulusBot was designed to carry the MouseBot and to be deployed to the annulus space through a riser. To deploy the MouseBot to every ventilation channel in the annulus, the arm consisting of a boom and a forearm was used to place the MouseBot on the underside of the tank. The AnnulusBot used segmented wheels enable to traverse pipes and other potential obstacles. The cable management system utilized motorized wheels to feed the cable into the ventilation channel. This would reduce the amount of work that the MouseBot would have to do during inspection. This feeding mechanism would also be used to retrieve the MouseBot at the end of its inspection. Additionally, if the MouseBot fails, this mechanism would be used for retrieval. Once deployed, the MouseBot navigates to the center of the tank via the air ventilation channel beneath the inner shell (the primary tank) while inspecting the space. The MouseBot is then retrieved from the channel by a combination of its own drive power and the AnnulusBot retracting the attached umbilical cord. Compare with the AnnulusBot, the physical dimensional limitations of the MouseBot were a greater challenge. As the surface state of the concrete of the air channels could have variable texture, and may contain debris, it was decided not to travel along this surface. The ceiling of these channels is carbon steel and can be utilized throughout the channel. To use this travel surface, magnetic wheels were employed. A foreseeable problem with the use of magnets on this surface, is that they would preclude the use of eddy currents sensors. However, other technologies like ultrasonic technology sensors should be unaffected. Laboratory scale test was performed on a mock-up single wedge of the refractory pad to evaluate maneuverability of the MouseBot. The electronic components for the prototype would work in the ranges of 150-185 deg. F (65.6-85 deg. C). Both the AnnulusBot and MouseBot will be subject to constant radiation. All major printed circuit board (PCB) microcontroller components were designed to be situated outside of the annulus space and inside the main control panel to avoid radiation-induced failure. As future work, electronic components including the Arduinos that used Atmel commercial microcontrollers will be replaced with the high temperature rated Atmel microcontrollers so that the robots can be operated reliably at ambient temperatures up to 200 deg. F (93.3 deg. C). In addition, the robots will be service life tested to evaluate performance at elevated temperature and under gamma irradiation. (authors)

42 ENGINEERING↗

Novel Radiometry for In-Pipe Robotic Inspection of Holdup Deposits in Gaseous Diffusion Piping - 19503

This paper details the first complete, DOE approved, deployed and operational radiometry for robotic nondestructive assay (NDA) of holdup deposits in gaseous diffusion piping. Some features, like peak-finding, Compton correction, detector efficiency, and material properties are characteristic of typical manual methods. Most features are specific to in-pipe robotic deployment. These include in-motion radiometry, self-determined location, geometric modeling of thick deposits, bounding of self-attenuation thickness and auto-checking of replicate measurements. Significant are the means for determining all the properties, equations, and constants for automatically computing and displaying all the quantities, uncertainties and information needed for NDA reporting, analysis, and review. Earlier work by this team demonstrated rudimentary but convincing robotic in-pipe NDA of holdup deposits in pipes. Cold testing with high-enrichment mat sources and hot tests with low U-235 loadings together succeeded to exhibit convincing proof-of-principle. This research-grade radiometry implementation lacked accurate odometry, efficiency calibration, high-fidelity detector modeling, attenuation modeling, forward geometric modeling, auto-segmenting, uncertainty modeling, replicate checking, deconvolution and much more. This work explains the technical basis behind robotic in-pipe NDA. It includes discussion of a new method for modeling of self-attenuation using in-pipe deposit geometry information, detail of the method's total measurement uncertainty, and explanation of calibration methods and results. Beyond development of automation-specific radiometric elements, the paper highlights analyses, testing, and technical bases specific to and supportive of the methodology. Examples include collimation characterization, detector efficiency determination, auto-calibration methodology, and odometric replicate-checking. Results of this methodology are formalized in a DOE EM Technical Basis Document, implemented in software, formally verified in review and acceptance testing and proceduralized as a means for D and D NDA at the Portsmouth enrichment facility. Measurement of U-235 quantity is a well-known cost and schedule driver in D and D of every defunct gaseous diffusion enrichment facility in the world. The radiometry methodologies and results detailed in this paper were the high hurdles. Having established the technical basis for this automated NDA, the opportunity is to apply this to many sizes and robot forms for addressing holdup deposit NDA throughout the D and D community. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

R and DE Robotic Sensor Intern Team: Remote 3D Mapping Overview

The Department of Energy (DOE) nuclear complex includes many hazardous and challenging environments that must be inspected remotely and routinely for structural integrity evaluation and long-term planning purposes. The H-Canyon Air Exhaust (HCAEX) Tunnel biannual inspection is an example of such an environment. Presently inspections are performed by teleoperated robotic crawlers provide low resolution video feedback to the structural engineers. Advanced sensors such as Lidar and panospheric hi-res cameras have the potential to provide additional valuable data in future inspections. UT-Austin Lidar work in support of an H-Canyon deployment began with the DOE EM sponsored H-Canyon Integrated Research Project. The R and DE Robotic Sensor intern team includes two of the UT-Austin Masters students working on Lidar development to facilitate the pulling of university developed solutions to the field. The goal of this project is to develop a suite of sensors that could be used to gather advanced data in future HCAEX tunnel inspections. Of particular interest is the ability to map the tunnel walls at an accuracy that will allow for the comparison of two scans performed at different time periods to estimate the concrete erosion rate. Additionally, the development of the 3D point cloud in the GPS denied environment is the first step in being able to collect and overlay other 3D data such as radiation mapping. Project specific goals include: - Design and develop 3D mapping sensor suite. Merge Lidar point cloud with high res camera images Incorporate Inertial Measurement Unit (IMU) to assist with positioning. - Develop sensor software and user GUI Sensor data collection and integration software User GUI for reach back system. - Test solution on crawler in tunnel test bed Use crawler base similar to H-Canyon planned crawler Design and build test bed simulating tunnel conditions. To facilitate rapid sensor integration, software coding and user GUI development, the Robot Operating System (ROS) was employed as the development platform. ROS is a set of open source software libraries and tools that assist with the building of robot applications. ROS includes drivers for many sensors, state-of-the-art algorithms, and powerful developer tools. Sensors selected for the summer intern solution included assessment as to whether they possessed ROS drivers and associated sample code. Additionally, the ROS 3D Robot Visualizer (rviz) tool has been employed.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Robotic Assisted Non-Destructive Testing (NDT)

Mission Statement: Concrete wall characterization for structural integrity evaluation of H-Canyon exhaust tunnel using a remote controlled robotic arm with a NDT Concrete Instrument. Challenges: Rough and Curved Surfaces, Remote location. The UR5 is a collaborative robotic arm capable of: Payload: 11 lbs (5 kg), Reach: 33.5 in (850 mm), Footprint: 5.87 in (149 mm) diameter, Weight: 45.4 Ibs (20.6 kg). The force torque sensor reacts to a set value inputted by the user that can be utilized for sensitive products. This allows the UR5 to react to surfaces using the built-in function to search for a wall and orient itself normal to that plane. The Proceq Pundit 250 array is a nondestructive device that the user applies against a concrete wall and scans using ultrasonic transducers. The back wall and other defects can be show through the touchscreen. A fixture to hold the Proceq Pundit 250 array onto the UR5 robotic arm was designed and 3D printed. It includes openings for easy access to the buttons from the Pundit array as well as a reinforced structural design. The scan from the Pundit array can show the back-wall, rebars, and other defects to assist in determining the structural integrity. In order to scan, a program was made to search for the wall first. 1. The UR5 robotic arm will go to the desired location away from the wall. 2. It will then search for the wall by moving towards it slowly. 3. After contact, the force applied will slowly but steadily increase to a preset value inputted by the user. 4. The force torque sensor will use those values and communicate with the UR5 by adjusting the arm to become normal to the wall. 5. The arm will then apply force to push back the transducers on the Pundit array to avoid gaps. 6. It will then prompt the user to collect data and wait until finished. The UR5 teach pendant allows the user to program the robot to perform automated and repeatable tasks. It includes a free drive mode which allows the user to move the arm to a desired position by hand. The user can also apply restricted planes which include either stopped or slower motion to ensure safety. The concrete sample being tested includes rebars and different grades of surface roughness to understand the readings from the Proceq Pundit 250 array. Desired concrete samples are currently being fabricated that will simulate the terrain being tested.

3D PRINTING↗

High-precision control of tracked field robots in the presence of unknown traction coefficients

Accurate steering through crop rows that avoids crop damage is one of the most important tasks for agricultural robots utilized in various field operations, such as monitoring, mechanical weeding, or spraying. In practice, varying soil conditions can result in off-track navigation due to unknown traction coefficients so that it can cause crop damage. To address this problem, this work presents the development, application, and experimental results of a real-time receding horizon estimation and control (RHEC) framework applied to a fully autonomous mobile robotic platform to increase its steering accuracy. Recent advances in cheap and fast microprocessors, as well as advances in solution methods for nonlinear optimization problems, have made nonlinear receding horizon control (RHC) and receding horizon estimation (RHE) methods suitable for field robots that require high-frequency (milliseconds) updates. A real-time RHEC framework is developed and applied to a fully autonomous mobile robotic platform designed by the authors for in-field phenotyping applications in sorghum fields. Nonlinear RHE is used to estimate constrained states and parameters, and nonlinear RHC is designed based on an adaptive system model that contains time-varying parameters. The capabilities of the real-time RHEC framework are verified experimentally, and the results show an accurate tracking performance on a bumpy and wet soil field. Finally, the mean values of the Euclidean error and required computation time of the RHEC framework are equal to 0.0423 m and 0.88 ms, respectively.

42 ENGINEERING↗

Energy Efficient Legged Robotics at Sandia Labs, Part 2

Sandia is developing energy efficient actuation and drive train technologies to dramatically improve the charge life of legged robots. The work is supported by DARPA, and Sandia will demonstrate an energy efficient bipedal robot at the technology exposition section of the DARPA Robotics Challenge Finals in June, 2015. This video, the second in a series, describes the continued development and integration of the Sandia Transmission Efficient Prototype Promoting Research (STEPPR) robot.

42 ENGINEERING↗

Autonomous elemental characterization enabled by a low cost robotic platform built upon a generalized software architecture

Despite the rapidly growing applications of robots in industry, the use of robots to automate tasks in scientific laboratories is less prolific due to the lack of generalized methodologies and the high cost of hardware. This paper focuses on the automation of characterization tasks necessary for reducing cost while maintaining generalization and proposes a software architecture for building robotic systems in scientific laboratory environments. A dual-layer (Socket.IO and ROS) action server design is the basic building block, which facilitates the implementation of a web-based front end for user-friendly operation and the use of ROS Behavior Trees for convenient task planning and execution. A robotic platform for automating mineral and material sample characterization is built upon the architecture, with an open-source, low-cost three-axis computer numerical control gantry system serving as the main robot. A handheld laser induced breakdown spectroscopy (LIBS) analyzer is integrated with a 3D printed adapter, enabling (1) automated 2D chemical mapping and (2) autonomous sample measurement (with the support of an RGB-Depth camera). We demonstrate the utility of automated chemical mapping by scanning the surface of a spodumene-bearing pegmatite core sample with a 1071-point dense hyperspectral map acquired at a rate of 1520 bits per second. Furthermore, we showcase the autonomy of the platform in terms of perception, dynamic decision-making, and execution, through a case study of LIBS measurement of multiple mineral samples. The platform enables controlled and autonomous chemical quantification in the laboratory that complements field-based measurements acquired with the same handheld device, linking resource exploration and processing steps in the supply chain for lithium-based battery materials.

Cao, Xuan [Lawrence Berkeley National Laboratory (↗

Torch End-Effector and TIG Electrode Changeout Design for a TIG Welding Robot Used in Metal Big Area Additive Manufacturing

Metal Big Area Additive Manufacturing (mBAAM) is a promising approach to large-scale metal additive manufacturing (AM) or 3D printing. The mBAAM system uses an arc-based wire-fed welding robot to build metal parts. A multi-degree-of-freedom robotic arm is known for its extensive range of motion and reliable tool handling. Attaching a torch end-effector to a robotic arm gives it welding capabilities; however, this decreases the motion range and dynamics of the robot. As a result, build volume and printing accuracy are decreased. Additionally, only a portion of time is spent printing in an arc-based process. Maintenance leads to downtime on the system. In a tungsten inert gas (TIG)-based process, the torch electrode wears out over time and must be changed to avoid defective deposition. This paper proposes an approach for a compact torch end-effector to improve the robot’s build volume. This paper also proposes an approach to reducing non-printing process time by designing and implementing a semi-automated electrode changing system.

Masuo, Chris↗

Commissioning of a proton gantry equipped with dual x-ray imagers and a robotic patient positioner, and evaluation of the accuracy of single-beam image registration for this system

Purpose: To check the accuracy of a gantry equipped with dual x-ray imagers and a robotic patient positioner for proton radiotherapy, and to evaluate the accuracy and feasibility of single-beam registration using the robotic positioner. Methods: One of the proton treatment rooms at their institution was upgraded to include a robotic patient positioner (couch) with 6 degrees of freedom and dual orthogonal kilovoltage x-ray imaging panels. The wander of the proton beam central axis, the wander of the beamline, and the orthogonal image panel crosswires from the gantry isocenter were measured for different gantry angles. The couch movement accuracy and couch wander from the gantry isocenter were measured for couch loadings of 50–300 lb with couch rotations from 0° to ±90°. The combined accuracy of the gantry, couch, and imagers was checked using a custom-made 30 × 30 × 30 cm{sup 3} Styrofoam phantom with beekleys embedded in it. A treatment in this room can be set up and registered at a setup field location, then moved precisely to any other treatment location without requiring additional image registration. The accuracy of the single-beam registration strategy was checked for treatments containing multiple beams with different combinations of gantry angles, couch yaws, and beam locations. Results: The proton beam central axis wander from the gantry isocenter was within 0.5 mm with gantry rotations in both clockwise (CW) and counterclockwise (CCW) directions. The maximum wander of the beamline and orthogonal imager crosswire centers from the gantry isocenter were within 0.5 and 0.8 mm, respectively, with the gantry rotations in CW and CCW directions. Vertical and horizontal couch wanders from the gantry isocenter were within 0.4 and 1.3 mm, respectively, for couch yaw from 0° to ±90°. For a treatment with multiple beams with different gantry angles, couch yaws, and beam locations, the measured displacements of treatment beam locations from the one based on the initial setup beam registered at the gantry at 0°/180° and couch yaw at 0° were within 1.5 mm in three translations and 0.5° in three rotations for a 200 lb couch loading. Conclusions: Results demonstrate that the gantry equipped with a robotic patient positioner and dual imaging panels satisfies treatment requirements for proton radiotherapy. The combined accuracy of the gantry, couch, and imagers allows a patient to be registered at one setup position and then moved precisely to another treatment position by commanding the robotic patient positioner and delivering treatment without requiring additional image registration.

07 ISOTOPE AND RADIATION SOURCES↗

SU-E-J-12: An Image-Guided Soft Robotic Patient Positioning System for Maskless Head-And-Neck Cancer Radiotherapy: A Proof-Of-Concept Study

Purpose: We propose a surface-image-guided soft robotic patient positioning system for maskless head-and-neck radiotherapy. The ultimate goal of this project is to utilize a soft robot to realize non-rigid patient positioning and real-time motion compensation. In this proof-of-concept study, we design a position-based visual servoing control system for an air-bladder-based soft robot and investigate its performance in controlling the flexion/extension cranial motion on a mannequin head phantom. Methods: The current system consists of Microsoft Kinect depth camera, an inflatable air bladder (IAB), pressured air source, pneumatic valve actuators, custom-built current regulators, and a National Instruments myRIO microcontroller. The performance of the designed system was evaluated on a mannequin head, with a ball joint fixed below its neck to simulate torso-induced head motion along flexion/extension direction. The IAB is placed beneath the mannequin head. The Kinect camera captures images of the mannequin head, extracts the face, and measures the position of the head relative to the camera. This distance is sent to the myRIO, which runs control algorithms and sends actuation commands to the valves, inflating and deflating the IAB to induce head motion. Results: For a step input, i.e. regulation of the head to a constant displacement, the maximum error was a 6% overshoot, which the system then reduces to 0% steady-state error. In this initial investigation, the settling time to reach the regulated position was approximately 8 seconds, with 2 seconds of delay between the command start of motion due to capacitance of the pneumatics, for a total of 10 seconds to regulate the error. Conclusion: The surface image-guided soft robotic patient positioning system can achieve accurate mannequin head flexion/extension motion. Given this promising initial Result, the extension of the current one-dimensional soft robot control to multiple IABs for non-rigid positioning control will be pursued.

60 APPLIED LIFE SCIENCES↗

SU-F-BRA-04: Prostate HDR Brachytherapy with Multichannel Robotic System

Purpose: High-dose-rate (HDR) brachytherapy is gradually becoming popular in treating patients with prostate cancers. However, placement of the HDR needles at desired locations into the patient is challenging. Application of robotic system may improve the accuracy of the clinical procedure. This experimental study is to evaluate the feasibility of using a multichannel robotic system for prostate HDR brachytherapy. Methods: In this experimental study, the robotic system employed was a 6-DOF Multichannel Image-guided Robotic Assistant for Brachytherapy (MIRAB), which was designed and fabricated for prostate seed implantation. The MIRAB has the provision of rotating 16 needles while inserting them. Ten prostate HDR brachytherapy needles were simultaneously inserted using MIRAB into a commercially available prostate phantom. After inserting the needles into the prostate phantom at desired locations, 2mm thick CT slices were obtained for dosimetric planning. HDR plan was generated using Oncetra planning system with a total prescription dose of 34Gy in 4 fractions. Plan quality was evaluated considering dose coverage to prostate and planning target volume (PTV), with 3mm margin around prostate, as well as the dose limit to the organs at risk (OARs) following the American Brachytherapy Society (ABS) guidelines. Results: From the CT scan, it is observed that the needles were inserted straight into the desired locations and they were adequately spaced and distributed for a clinically acceptable HDR plan. Coverage to PTV and prostate were about 91% (V100= 91%) and 96% (V100=96%), respectively. Dose to 1cc of urethra, rectum, and bladder were within the ABS specified limits. Conclusion: The MIRAB was able to insert multiple needles simultaneously into the prostate precisely. By controlling the MIRAB to insert all the ten utilized needles into the prostate phantom, we could achieve the robotic HDR brachytherapy successfully. Further study for assessing the system’s performance and reliability is in progress.

60 APPLIED LIFE SCIENCES↗

SU-F-T-576: Characterization of Two Dimensional Liquid Filled Detector Array(SRS 1000) in High Precision Cyberknife Robotic Radiosurgery System

Purpose: The aim of the study is to characterize a two dimensional liquid filled detector array SRS 1000 for routine QA in Cyberknife Robotic Radiosurgery system. Methods: SRS 1000 consists of 977 liquid filled ionization chambers and is designed to be used in small field SRS/SBRT techniques. The detector array has got two different spacial resolutions. Till field size of 5.5×5.5 cm the spacial resolution is 2.5mm (center to center) and after that till field size of 11 × 11 cm the spacial resolution is 5mm. The size of the detector is 2.3 × 2.3 0.5 mm with a volume of .003 cc. The CyberKnife Robotic Radiosurgery System is a frameless stereotactic radiosurgery system in which a LINAC is mounted on a robotic manipulator to deliver beams with a high sub millimeter accuracy. The SRS 1000’s MU linearity, stability, reproducibility in Cyberknife Robotic Radiosurgery system was measured and investigated. The output factors for fixed and IRIS collimators for all available collimators (5mm till 60 mm) was measured and compared with the measurement done with PTW pin-point ionization chamber. Results: The MU linearity was measured from 2 MU till 1000 MU for doserates in the range of 700cGy/min – 780 cGy/min and compared with the measurement done with pin point chamber The MU linearity was with in 3%. The detector arrays stability and reproducibility was excellent and was withinin 0.5% The measured output factors showed an agreement of better than 2% when compared with the measurements with pinpoint chamber for both fixed and IRIS collimators with all available field sizes. Conclusion: We have characterised PTW 1000 SRS as a precise and accurate measurement tool for routine QA of Cyberknife Robotic radiosurgery system.

60 APPLIED LIFE SCIENCES↗

TU-FG-BRB-11: Design and Evaluation of a Robotic C-Arm CBCT System for Image-Guided Proton Therapy

Purpose: To describe the design and performance of a ceiling-mounted robotic C-arm CBCT system for image-guided proton therapy. Methods: Uniquely different from traditional C-arm CBCT used in interventional radiology, the imaging system was designed to provide volumetric image guidance for patients treated on a 190-degree proton gantry system and a 6 degree-of-freedom (DOF) robotic patient positioner. The mounting of robotic arms to the ceiling rails, rather than gantry or nozzle, provides the flexibility in imaging locations (isocenter, iso+27cm in X, iso+100cm in Y) in the room and easier upgrade as technology advances. A kV X-ray tube and a 43×43cm flat panel imager were mounted to a rotating C-ring (87cm diameter), which is coupled to the C-arm concentrically. Both C-arm and the robotic arm remain stationary during imaging to maintain high position accuracy. Source-to-axis distance and source-to-imager distance are 100 and 150cm, respectively. A 14:1 focused anti-scatter grid and a bowtie filer are used for image acquisition. A unique automatic collimator device of 4 independent blades for adjusting field of view and reducing patient dose has also been developed. Results: Sub-millimeter position accuracy and repeatability of the robotic C-arm were measured with a laser tracker. High quality CBCT images for positioning can be acquired with a weighted CTDI of 3.6mGy (head in 200° full fan mode: 100kV, 20mA, 20ms, 10fps)-8.7 mGy (pelvis in 360° half fan mode: 125kV, 42mA, 20ms, 10fps). Image guidance accuracy achieved <1mm (3D vector) with automatic 3D-3D registration for anthropomorphic head and pelvis phantoms. Since November 2015, 22 proton therapy patients have undergone daily CBCT imaging for 6 DOF positioning. Conclusion: Decoupled from gantry and nozzle, this CBCT system provides a unique solution for volumetric image guidance with half/partial proton gantry systems. We demonstrated that daily CBCT can be integrated into proton therapy for pre-treatment position verification.

60 APPLIED LIFE SCIENCES↗

TH-EF-BRB-08: Robotic Motion Compensation for Radiation Therapy: A 6DOF Phantom Study

Purpose: The high accuracy of frame-based stereotactic radiosurgery (SRS), which uses a rigid frame fixed to the patient’s skull, is offset by potential drawbacks of poor patient compliance and clinical workflow restrictions. Recent research into frameless SRS has so far resulted in reduced accuracy. In this study, we investigate the use of a novel 6 degree-of-freedom (6DOF) robotic head motion cancellation system that continuously detects and compensates for patient head motions during a SRS delivery. This approach has the potential to reduce invasiveness while still achieving accuracies better or equal to traditional frame-based SRS. Methods: A 6DOF parallel kinematics robotics stage was constructed, and controlled using an inverse kinematics-based motion compensation algorithm. A 6DOF stereoscopic infrared (IR) marker tracking system was used to monitor real-time motions at sub-millimeter and sub-degree levels. A novel 6DOF calibration technique was first applied to properly orient the camera coordinate frame to match that of the LINAC and robotic control frames. Simulated head motions were measured by the system, and the robotic stage responded to these 6DOF motions automatically, returning the reflective marker coordinate frame to its original position. Results: After the motions were introduced to the system in the phantom-based study, the robotic stage automatically and rapidly returned the phantom to LINAC isocenter. When errors exceeded the compensation lower threshold of 0.25 mm or 0.25 degrees, the system registered the 6DOF error and generated a cancellation trajectory. The system responded in less than 0.5 seconds and returned all axes to less than 0.1 mm and 0.1 degree after the 6DOF compensation was performed. Conclusion: The 6DOF real-time motion cancellation system was found to be effective at compensating for translational and rotational motions to current SRS requirements. This system can improve frameless SRS by automatically returning patients to isocenter with high 6DOF accuracy.

60 APPLIED LIFE SCIENCES↗

A self-supervised robotic system for autonomous contact-based spatial mapping of semiconductor properties

Integrating robotically driven contact-based material characterization techniques into self-driving laboratories can enhance measurement quality, reliability, and throughput. While deep learning models support robust autonomy, current methods lack reliable pixel-precision positioning and require extensive labeled data. To overcome these challenges, we propose an approach for building self-supervised autonomy into contact-based robotic systems that teach the robot to follow domain expert measurement principles at high throughputs. We demonstrate the performance of this approach by autonomously driving a 4-DOF robotic probe for 24 hours to characterize semiconductor photoconductivity at 3025 uniquely predicted poses across a gradient of drop-casted perovskite film compositions, achieving throughputs of more than 125 measurements per hour. Spatially mapping photoconductivity onto each drop-casted film reveals compositional trends and regions of inhomogeneity, valuable for identifying manufacturing defects. With this self-supervised neural network–driven robotic system, we enable high-precision and reliable automation of contact-based characterization techniques at high throughputs, thereby allowing measurement of previously inaccessible yet important semiconductor properties for self-driving laboratories.

Science & Technology - Other Topics↗

Robotic Extended Right Hemicolectomy with Complete Mesocolic Excision and D3 Lymph Node Dissection

Background: Recent studies have shown the benefits of complete mesocolic excision and extended lymphadenectomy (D3 lymph node dissection) in patients with colon cancer.1{sup –}3 Methods: We present the case of a 62-year-old male with hepatic flexure adenocarcinoma. No metastatic disease was identified by computed tomography. A robot-assisted extended right hemicolectomy with complete mesocolic excision, D3 lymph node dissection, and resection of the mesentery with intact visceral peritoneum was performed. Results: The trocars are placed in the right lower (8 mm), lower midline (8 mm), and left upper (12 mm) quadrants. The camera port is placed superior to the umbilicus, and the assistant port is placed in the left lower quadrant. The robotic right lower port is used to place the cecum on tension in order to outline the ileocolic pedicle. The assistant retracts the transverse colon cephalad to outline the superior mesenteric artery and vein. Using two robotic arms, the surgeon begins dissection over the superior mesenteric vein inferior to the ileocolic pedicle. Cephalad dissection along the superior mesenteric vein proceeds with reflection of the mesentery and D3 lymph nodes laterally to allow en bloc resection. The ileocolic and middle colic vessels are identified, ligated and divided at their origins. The plane is then developed between the right colon mesentery and the retroperitoneum, including Gerota’s fascia, duodenum, and head of the pancreas, in a medial-to-lateral fashion, with care taken to ensure an intact visceral peritoneum is maintained. The proximal transverse colon, hepatic flexure, and ascending colon are mobilized by taking down lateral attachments. The intervening mesentery is transected, and perfusion is assessed with indocyanine green fluorescence imaging. An intracorporeal, isoperistaltic, side-to-side anastomosis is performed using the 45-mm robotic stapler. The common enterotomy is sewn closed in two layers. Pathology showed T3N0 adenocarcinoma with all negative margins. Conclusion: Extended right hemicolectomy with complete mesocolic excision and D3 lymph node dissection is facilitated by a robotic approach, which improves visualization and instrument dexterity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗