Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Response Spectrum”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

Ambient Mass Spectrometry Rapid Analysis Methods for Trace Inorganics

The ability to rapidly detect and characterize the chemistry of trace quantities of inorganic species has multiple potential applications, including nuclear safeguards, nuclear forensics, and environmental monitoring. Some mass spectrometric methods currently exist, but they are costly and time-intensive, often destroying chemical information in the process of ionization. Ambient mass spectrometry is a relatively new analytical method in which samples are introduced to the mass spectrometer from atmospheric pressure, rather than from high vacuum. Ambient MS can operate with gentler ionization methods such as electrospray ionization (ESI) and paper-spray ionization (PSI), reducing fragmentation and preserving the chemical information of the analyte. This may be useful for determining the intended purpose of material in a sample. Strontium, part of nuclear fallout, is analyzed here to test these new analytical methods for viability. Electrospray ionization mass spectrometry functions by spraying the sample as a solution through a needle charged to a few kV. A nebulizing gas flows out along with the sample to create the spray before droplets enter a drying chamber with heated drying gas to remove the solvent molecules. From there bare analyte ions enter the mass spectrometer. This method has the advantage of relatively fast sample preparation and stable ionization. More stable ionization produces higher-quality data. Paper-spray ionization mass spectrometry operates by applying sample to a paper triangle. The paper triangle is then electrified in a metal clamp to a few kV before spray solvent is applied. The spray solvent transports analyte in the sample to the tip, where it is ionized and enters the mass spectrometer. One advantage of this method is reduced sample preparation - an analyst can even swipe a surface and cut a triangle directly from the swipe. The data analysis serves to rapidly process tens of samples all at once. The mass spectrometer outputs a file containing a few hundred spectra for each sample. The pipeline processes each one to identify peaks of interest. A full palette of data analysis metrics are generated, including plots of the raw data and plots of calculated values such as isotopic ratios. The pipeline filters the raw data to remove noise and background peaks, as well as peaks representing detector saturation. A heat map is generated to show the overall spectrum in mass-time- intensity space. Post-processing, we obtained the desired calibration curves, demonstrating that both ESI-MS and PSI-MS are viable methods for quantifying trace amounts of inorganics while retaining their chemical speciation information. ESI-MS demonstrated a linear response region of 100 ppb to 20 ppm, with a limit-of-detection of around 100 ppb. At top left is an example spectrum with the {sup 88}SrNO{sub 3} peak identified to show the retention of chemical speciation. PSI-MS showed a linear response region of around 1 ppb to 1 ppm, with a limit-of-detection of near 1 ppb. PSI-MS produced more erratic results than ESI-MS, likely due to the variability in ionization resulting from manual positioning of the paper triangle near the MS inlet. Future efforts will focus on improving the repeatability of PSI-MS as well as analyzing other species of interest such as cerium and uranium. Improvements will also be made to create more reliable data extraction and intelligent data filtering.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A View from Above: Earth Observations

Since the 1960s, satellites have been looking down at the Earth to monitor weather patterns and track severe storms, observe how our land surface is changing and responding to hydrometerological extremes, and even to sense how the Earth's crust is deforming from earthquakes and volcanoes. Space and airborne platforms can provide unique views of the disaster lifecycle, informing pre-event mitigation and preparedness, emergency response following an event, and monitoring longer-term recovery. These remotely-sensed data, products and models can provide a global perspective to see beyond administrative boundaries, reach remote places where in situ observations are di cult or non-existent, and provide the necessary context and situational awareness to aid in disaster response. So how do these platforms work? Instruments aboard satellites use different portions of the electromagnetic spectrum to passively or actively observe energy across a range of wavelengths, which can be turned into meaningful data on geophysical, atmospheric, and hydrological variables. e US has had a broad range of Earth observation (EO) platforms delivering open data for scientific research and societal benefits for decades. e Landsat programme, a joint initiative between the US Geological Survey (USGS) and NASA, has the world's longest continuous collection of space-based satellite imagery of the Earth, extending from 1972 to present. e Landsat satellites provide visible, near infrared, and thermal data that are used to support emergency response and disaster relief by mapping changes in water during floods, and dramatic land surface changes, including those resulting from landslides, wild res, severe weather, volcanic plumes, and dust storms.

FEMA↗

PCP consensus protein/peptide alphavirus antigens stimulate broad spectrum neutralizing antibodies

Vaccines based on proteins and peptides may be safer and if calculated based on many sequences, more broad-spectrum than those designed based on single strains. Physicochemical Property Consensus (PCP con ) alphavirus (AV) antigens from the B-domain of the E2 envelope protein were designed, synthesized recombinantly and shown to be immunogenic (i.e. sera after inoculation detected the antigen in dotspots and ELISA). Antibodies in sera after inoculation with B-region antigens based on individual AV species (eastern or Venezuelan equine encephalitis (EEEV con , VEEV con ), or chikungunya (CHIKV con ) bound only their cognate protein, while those designed against multiple species (Mosaik con and EVC con ) recognized all three serotype specific antigens. The VEEV con and EEEV con sera only showed antiviral activity against their related strains (in plaque reduction neutralization assays (PRNT 50/80 ). Peptides designed to surface exposed areas of the E2-A-domain of CHIKV con were added to CHIKV con inocula to provide anti-CHIKV antibodies. EVC con , based on three different alphavirus species, combined with E2-A-domain peptides from AllAV con , a PCPcon of 24 diverse AV, generated broad spectrum, antiviral antibodies against VEEV, EEEV and CHIKV, AV with less than 35% amino acid identity to each other (>65% diversity). This is a promising start to a molecularly defined vaccine against all AV. A further study with these antigens can illuminate what areas are most important for a robust immune response, resistant to mutations in rapidly evolving viruses. The validated computational methods can also be used to design broad spectrum antigens against many other pathogen families.

59 BASIC BIOLOGICAL SCIENCES↗

Dispersive Charge Transfer State Electroluminescence in Organic Solar Cells

Abstract The notion of quasi‐equilibrium is central to most solar cells; however, it has been questioned in organic photovoltaics (OPVs) owing to strong energetic disorder that frustrates efficient relaxation of electrons and holes within their respective density of states (DOS). Here, modulation electroluminescence (EL) spectroscopy is applied to OPVs and it is found that the frequency response of charge transfer (CT) state EL on the high energy side of the spectrum differs from that of the low energy side. This observation confirms that static disorder contributes substantially to the linewidth of the steady‐state EL spectrum and is unambiguous proof that the distribution of CT states formed by electrical injection in the dark is not in quasi‐equilibrium. These results emphasize the need for caution when analyzing OPV cells on the basis of reciprocity models that assume quasi‐equilibrium holds, and highlight a new method to study this unusual aspect of OPV operation.

14 SOLAR ENERGY↗

Giant enhancement of nonreciprocity in gyrotropic heterostructures

Abstract Nonreciprocity is a highly desirable feature in photonic media since it allows for control over the traveling electromagnetic waves, in a way that goes far beyond ordinary filtering. One of the most conventional ways to achieve nonreciprocity is via employing gyrotropic materials; however, their time-reversal-symmetry-breaking effects are very weak and, hence, large, bulky setups combined with very strong magnetic biases are required for technologically useful devices. In this work, artificial heterostructures are introduced to enhance the effective nonreciprocal behavior by reducing the contribution of the diagonal susceptibilities in the collective response; in this way, the off-diagonal ones, that are responsible for nonreciprocity, seem bigger. In particular, alternating gyrotropic and metallic or plasmonic films make an epsilon-near-zero (ENZ) effective-medium by averaging the diagonal permittivities of opposite sign, representing the consecutive layers. The homogenization process leaves unaltered the nonzero off-diagonal permittivities of the original gyrotropic substance, which become dominant and ignite strong nonreciprocal response. Realistic material examples that could be implemented experimentally in the mid-infrared spectrum are provided while the robustness of the enhanced nonreciprocity in the presence of actual media losses is discussed and bandwidth limitations due to the unavoidable frequency dispersion are elaborated. The proposed concept can be extensively utilized in designing optical devices that serve a wide range of applications from signal isolation and wave circulation to unidirectional propagation and asymmetric power amplification.

42 ENGINEERING↗

The Electromagnetic Characteristics of the Tianlai Cylindrical Pathfinder Array

A great challenge for 21 cm intensity mapping experiments is the strong foreground radiation which is orders of magnitude brighter than the 21 cm signal. Removal of the foreground takes advantage of the fact that its frequency spectrum is smooth while the redshifted 21 cm signal spectrum is stochastic. However, a complication is the non-smoothness of the instrument response. This paper describes the electromagnetic simulation of the Tianlai cylinder array, a pathfinder for 21 cm intensity mapping experiments. Due to the vast scales involved, a direct simulation requires a large amount of computing resources. We have made the simulation practical by using a combination of methods: first simulate a single feed, then an array of feed units, finally with the feed array and a cylindrical reflector together, obtain the response for a single cylinder. We studied its radiation pattern, bandpass response and the effects of mutual coupling between feed units, and compared the results with observation. Many features seen in the measurement result are reproduced well in the simulation, especially the oscillatory features which are associated with the standing waves on the reflector. The mutual coupling between feed units is quantified with S-parameters, which decrease as the distance between the two feeds increases. Based on the simulated S-parameters, we estimate the correlated noise which has been seen in the visibility data, and the results show very good agreement with the data in both magnitude and frequency structures. These results provide useful insights on the problem of 21 cm signal extraction for real instruments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Identification and reconstruction of low-energy electrons in the ProtoDUNE-SP detector

Measurements of electrons from 𝜈𝑒 interactions are crucial for the Deep Underground Neutrino Experiment (DUNE) neutrino oscillation program, as well as searches for physics beyond the standard model, supernova neutrino detection, and solar neutrino measurements. This article describes the selection and reconstruction of low-energy (Michel) electrons in the ProtoDUNE-SP detector. ProtoDUNE-SP is one of the prototypes for the DUNE far detector, built and operated at CERN as a charged particle test beam experiment. A sample of low-energy electrons produced by the decay of cosmic muons is selected with a purity of 95%. This sample is used to calibrate the low-energy electron energy scale with two techniques. An electron energy calibration based on a cosmic ray muon sample uses calibration constants derived from measured and simulated cosmic ray muon events. Another calibration technique makes use of the theoretically well-understood Michel electron energy spectrum to convert reconstructed charge to electron energy. In addition, the effects of detector response to low-energy electron energy scale and its resolution including readout electronics threshold effects are quantified. Finally, the relation between the theoretical and reconstructed low-energy electron energy spectra is derived, and the energy resolution is characterized. The low-energy electron selection presented here accounts for about 75% of the total electron deposited energy. After the addition of lost energy using a Monte Carlo simulation, the energy resolution improves from about 40% to 25% at 50 MeV. These results are used to validate the expected capabilities of the DUNE far detector to reconstruct low-energy electrons.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Precision measurement of the electron energy-loss function in tritium and deuterium gas for the KATRIN experiment

Abstract The KATRIN experiment is designed for a direct and model-independent determination of the effective electron anti-neutrino mass via a high-precision measurement of the tritium $$\upbeta $$ β -decay endpoint region with a sensitivity on $$m_\nu $$ m ν of 0.2 $$\hbox {eV}/\hbox {c}^2$$ eV / c 2 (90% CL). For this purpose, the $$\upbeta $$ β -electrons from a high-luminosity windowless gaseous tritium source traversing an electrostatic retarding spectrometer are counted to obtain an integral spectrum around the endpoint energy of 18.6 keV. A dominant systematic effect of the response of the experimental setup is the energy loss of $$\upbeta $$ β -electrons from elastic and inelastic scattering off tritium molecules within the source. We determined the energy-loss function in-situ with a pulsed angular-selective and monoenergetic photoelectron source at various tritium-source densities. The data was recorded in integral and differential modes; the latter was achieved by using a novel time-of-flight technique. We developed a semi-empirical parametrization for the energy-loss function for the scattering of 18.6-keV electrons from hydrogen isotopologs. This model was fit to measurement data with a 95% $$\hbox {T}_2$$ T 2 gas mixture at 30 K, as used in the first KATRIN neutrino-mass analyses, as well as a $$\hbox {D}_2$$ D 2 gas mixture of 96% purity used in KATRIN commissioning runs. The achieved precision on the energy-loss function has abated the corresponding uncertainty of $$\sigma (m_\nu ^2)< {{10}^{-2}}{\hbox {eV}^{2}}$$ σ ( m ν 2 ) < 10 - 2 eV 2 [1] in the KATRIN neutrino-mass measurement to a subdominant level.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Single-pixel reconstructive mid-infrared micro-spectrometer

Miniaturized spectrometers in the mid-infrared (MIR) are critical in developing next-generation portable electronics for advanced sensing and analysis. The bulky gratings or detector/filter arrays in conventional micro-spectrometers set a physical limitation to their miniaturization. In this work, we demonstrate a single-pixel MIR micro-spectrometer that reconstructs the sample transmission spectrum by a spectrally dispersed light source instead of spatially grated light beams. The spectrally tunable MIR light source is realized based on the thermal emissivity engineered via the metal-insulator phase transition of vanadium dioxide (VO 2 ). We validate the performance by showing that the transmission spectrum of a magnesium fluoride (MgF 2 ) sample can be computationally reconstructed from sensor responses at varied light source temperatures. With potentially minimum footprint due to the array-free design, our work opens the possibility where compact MIR spectrometers are integrated into portable electronic systems for versatile applications.

47 OTHER INSTRUMENTATION↗

Characterization of the Polarization Beam Response of SPT-3G Using Point Sources

Precise measurements of cosmic microwave background (CMB) polarization require rigorous control of instrumental systematics. For the South Pole Telescope's third-generation camera (SPT-3G), which observes in three bands centered near 95, 150, and 220 GHz, accurate beam characterization is critical for interpreting the polarized mm-wave sky. We present direct measurements of SPT-3G's polarized beam response from observations of 100 bright extragalactic point sources. Previous SPT-3G power spectrum analyses introduced a phenomenological parameter, $β_{\rm pol}$, to describe the polarization preserved in beam sidelobes, and found evidence for significant depolarization from the requirement of inter-frequency polarization power spectrum consistency. Our direct measurements yield $β_{\rm pol}=0.89\pm0.10$ at 95 GHz, $1.08\pm0.10$ at 150 GHz, and $0.90\pm0.22$ at 220 GHz, indicating minimal sidelobe depolarization. We validate these results with systematic tests of posterior sampling versus bootstrap resampling, real-space versus Fourier-space analysis, temperature-to-polarization leakage handling, covariance determination, and source selection. Compared to values inferred from previous cosmological analyses, our results differ by an effective $1.3σ$. This apparent discrepancy is model dependent, because the point source analysis derives much of its $β_{\rm pol}$ constraining power from higher multipoles than the power spectrum analysis. These measurements therefore admit three explanations for the frequency-dependent residuals observed in the power spectrum analysis: a statistical fluctuation, the need for more sophisticated polarized beam models, or systematics other than beam depolarization.

de Haan, T. [KEK, Tsukuba]↗

Physical processes in H II regions.

Physical process effect on structure of H II REGIONS, noting ionization, Lyman continuum spectral distribution and radiative transfer frequency dependence on absorptive processes

FREQUENCY RESPONSE↗

Observations of Interchange Between Acceleration and Thermalization Processes in Auroral Electrons

The results of high time-resolution measurements of energetic electrons in an auroral break up are presented. Electrons with energies from 500 eV to over 100 keV and pitch angles from 0 to 150 deg were detected with two detectors onboard sounding rocket 18:63 UE. Complete energy spectra were taken every 0.1 seconds. The procedure for cleaning and activating the BeCu dynodes of a small, rugged, high gain electron multiplier is described. A theoretical study of the energy-angular response of a spherical plate electrostatic analyzer is compared to experimental results. An energy spectrum unfolding technique which does not require the assumption of a histogram-type energy spectrum is presented. A method of determining sounding rocket orientation from the output of a single magnetometer is described.

Pongratz, M. B.↗

The large space telescope instrumentation.

Aspects of the Large Space Telescope project (LST) as it is developing at the Goddard Space Flight Center are presented and a brief discussion is given of the types of observing program that might be handled. The special characteristics of an LST are large light-gathering power, good spectral efficiency from 900 A to 5 microns, near diffraction limited performance, launch by the space shuttle into a low orbit like that of the Orbiting Astronomical Observatories, and a lifetime of at least 10 years. A basic set of instruments to be used with the telescope might include on-axis cameras with broad-band filter response, an imaging spectrograph, a low-resolution spectrograph, a high-resolution spectrograph, spectrum scanners, narrow-band photometers, interferometers for use in the near infrared, polarimeters for use in the ultraviolet, and provision for measuring the time variations of the light from astronomical objects on a scale of milli-seconds as well as on a scale of minutes, hours, days, and weeks.

Underhill, A. B.↗

An empirical spectral bandwidth model for superior conjunction

The downlink signal from spacecraft in superior solar conjunction phases suffers a great reduction in signal-to-noise ratio. Responsible in large part for this effect is the line broadening of the signal spectrum. An analytic empirical expression was developed for spectral bandwidth as a function of heliocentric distance from 1 to 20 solar radii. The study is based on spectral broadening data obtained from the superior conjunctions of Helios 1 (1975), Helios 2 (1976), and Pioneer 6 (1968). The empirical fit is based in part on a function describing the electron content in the solar corona.

Rockwell, R. S.↗

Spectral characterization of the Landsat-4 MSS sensors

Two multispectral scanner subsystems (MSS) have been fabricated and tested by an American aerospace company for the NASA Landsat program. One MSS, designated the protoflight (PF) model, was integrated into the Landsat-4 spacecraft, which was launched on July 16, 1982. The second, designated the flight (F) model, has been integrated into the Landsat-4 backup satellite, which is scheduled for possible launch in 1985. Each MSS has four bands in the reflective portion of the electromagnetic spectrum. The engineering test data which were collected included channel-by-channel spectral response curves. A description of the test procedure is included in Appendix A. This document is to make available to the Landsat user community data on the spectral characteristics of the two sensors. The Landsat-4 PF and F scanners were found to be essentially identical in mean spectral response.

Markham, B. L.↗

Design Spectrum Analysis in NASTRAN

The utility of Design Spectrum Analysis is to give a mode by mode characterization of the behavior of a design under a given loading. The theory of design spectrum is discussed after operations are explained. User instructions are taken up here in three parts: Transient Preface, Maximum Envelope Spectrum, and RMS Average Spectrum followed by a Summary Table. A single DMAP ALTER packet will provide for all parts of the design spectrum operations. The starting point for getting a modal break-down of the response to acceleration loading is the Modal Transient rigid format. After eigenvalue extraction, modal vectors need to be isolated in the full set of physical coordinates (P-sized as opposed to the D-sized vectors in RF 12). After integration for transient response the results are scanned over the solution time interval for the peak values and for the times that they occur. A module called SCAN was written to do this job, that organizes these maxima into a diagonal output matrix. The maximum amplifier in each mode is applied to the eigenvector of each mode which then reveals the maximum displacements, stresses, forces and boundary reactions that the structure will experience for a load history, mode by mode. The standard NASTRAN output processors have been modified for this task. It is required that modes be normalized to mass.

Butler, T. G.↗

Profile modification to minimize spur gear dynamic loading

An analytical computer simulation program for dynamic modeling of low-contact-ratio spur gear systems is presented. The procedure computes the static transmission error of the gears operating under load and uses a fast Fourier transform to generate the frequency spectrum of the static transmission error at various tooth profile modifications. The dynamic loading response of an unmodified (perfect involute) gear pair was compared with that of gears with various profile modifications. Correlations were found between various profile modifications and the resulting dynamic loads. An effective error, obtained from frequency domain analysis of the static transmission error of the gears, gave a very good indication of the optimum profile modification to reduce gear dynamic loading. Design curves generated by dynamic simulation at various profile modifications are given for gear systems operated at various loads. Optimum profile modifications can be determined from these design curves for improved gear design.

Lin, Hsiang Hsi↗

Profile modification to minimize spur gear dynamic loading

An analytical computer simulation program for dynamic modeling of low-contact-ratio spur gear systems is presented. The procedure computes the static transmission error of the gears operating under load and uses a fast Fourier transform to generate the frequency spectrum of the static transmission error at various tooth profile modifications. The dynamic loading response of an unmodified (perfect involute) gear pair was compared with that of gears with various profile modifications. Correlations were found between various profile modifications and the resulting dynamic loads. An effective error, obtained from frequency domain analysis of the static transmission error of the gears, gave a very good indication of the optimum profile modification to reduce gear dynamic loading. Design curves generated by dynamic simulation at various profile modifications are given for gear systems operated at various loads. Optimum profile modifications can be determined from these design curves for improved gear design.

Lin, H. H.↗