Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Reliability Testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

Optimum structural design based on reliability and proof-load testing

Proof-load test eliminates structures with strength less than the proof load and improves the reliability value in analysis. It truncates the distribution function of strength at the proof load, thereby alleviating verification of a fitted distribution function at the lower tail portion where data are usually nonexistent.

Shinozuka, M.↗

Development and testing of coarse-grained models for ultrasonic simulations of cast austenitic stainless steel

Ultrasonic inspection of cast austenitic stainless steel (CASS) in the nuclear industry is particularly challenging because of sound field scatter and attenuation caused by the coarse-grained microstructure. Modeling and simulation are important tools in ultrasonic testing, as they can be used to help address key aspects of inspections, such as developing new probe designs, predicting inspection reliability, and testing phased-array focal laws. However, developing a useful and reliable CASS model is challenging due to the many grain interfaces and crystalline orientations that must be captured. We demonstrate a method of creating a realistic CASS model that is usable in CIVA, a commercially available modeling and simulation software platform. Using polished and chemically etched sections, we generate models of a coarse-grained equiaxed specimen and a columnar specimen. We also test an alternative method of generating a coarse-grained model using Voronoi regions. We qualitatively compare sound field scatter and quantitatively compare sound field attenuation and beam partitioning in simulated sound fields to those of laboratory-measured sound fields. Results show that the Voronoi models perform as well as or better than the models based on actual grain morphology. Here we also show that model-to-model randomness in Voronoi grain structure can impact the magnitude of a simulated echo response by a factor of two or more. Although CASS models are potentially a good depiction of reality for a given scenario, they should not be considered representative since CASS morphology can change significantly from specimen to specimen or within the same specimen.

36 MATERIALS SCIENCE↗

Development of a Relational-Design Database for Preservation and Analysis of Historic Measurements of Radionuclides in Soil

Between 1981 and 1986, in situ spectral gamma measurements were made from tracked vehicles as part of the Radionuclide Inventory and Distribution Program (RIDP) to document the distribution and develop inventories of 16 man-made radionuclides in surface soil from nuclear testing at the Nevada Test Site. To preserve and permit more precise geospatial and other electronic analysis of the data, the raw spectral gamma measurements (units of nanocuries/m2) were recovered from nine-track magnetic tapes, transferred to a flat-file database, and finally converted into a relational-design, desktop application in Microsoft Access 2000. To test the reliability of the measurement locations, the Nevada Grid Coordinate information was imported into Environmental Systems Research Institute (ESRI) ArcMap to compare against plots in the 1991 RIDP summary report and against known field points. The resulting RIDP Database allows users to create files of the location and concentration where each radionuclide was detected, or files of all gamma measurements associated with a particular nuclear test. Maps can be generated showing where particular radionuclides were detected. For additional analysis, datasets can be exported to a hypertext markup language (HTML) format. Extensive use has been made of RIDP data prior to development of this database. However, there have been some inconsistencies in results because of use of interim results published prior to 1991, and because some half lives used when the data was collected are different than those used today. Two major steps were taken to standardize analysis using the RIDP database. First, only spectral gamma data decay corrected to January 1, 1990 was used. Second, currently accepted half lives for the radionuclides were incorporated into an option that allows decay correction of inventory and activity values since 1990. For long-lived radionuclides, changes in inventory have been inconsequential. However, for short-lived fission products (e.g., 60Co, half life of 5.27 years), changes because of radioactive decay were found to be significant. Comparison of spectral gamma data collected in 1994 from fixed winged aircraft to RIDP shows good correlation between areas of high contaminant concentration.

54 ENVIRONMENTAL SCIENCES↗

A differential approach to microcomputer test battery development and implementation

The present microcomputer-based performance test battery emphasizes psychometric theory and utility for repeated-measures applications during extended exposure to various environmental stressors. In the menu that has been defined at the current state of this system's development, there are more than 30 'qualified' mental tests which stabilize in less than 10 min and possess test-retest reliabilities greater than 0.7 for a three-minute test/work period. The battery encompasses tests of cognition, information processing, psychomotor skill, memory, mood, etc. Several of the tests have demonstrated sensitivity to chemoradiotherapy, sleep loss, hypoxia, amphetamines, thermal stress, sensory deprivation, altitude, fatigue, and alcohol use. Recommendations are presented for 6-, 12-, and 22-min batteries.

Kennedy, R. S.↗

Building Energy Simulation Test for Existing Homes (BESTEST-EX); Phase 1 Test Procedure: Building Thermal Fabric Cases

The U.S. Department of Energy tasked NREL to develop a process for testing the reliability of models that predict retrofit energy savings, including their associated calibration methods. DOE asked NREL to conduct the work in phases so that a test procedure would be ready should DOE need it to meet legislative requirements related to residential retrofits in FY 2010. This report documents the initial 'Phase 1' test procedure.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Evaluation of 1/100-Scale Mooring Systems for Wave Energy Converters

This study evaluates the feasibility, accuracy, and limitations of using 1/100th scale physical mooring systems to represent full-scale mooring behavior for wave energy converters (WECs) during small-scale tank testing. The work focuses on an RM3-style point absorber deployed in conditions representative of the PacWave South test site and examines whether small-scale physical testing can reliably inform numerical modeling, design decisions, and future prototype development. Overall, this study concludes that small-scale (1/100th) physical mooring models can provide valuable qualitative insights, including relative comparisons between mooring types and trends in device behavior, but cannot reliably replicate full-scale mooring loads or dynamic response without significant scaling distortion. Physical tests at this scale are most appropriate for motion characterization and model validation within known limitations, not for deriving absolute mooring loads or final engineering design values. Key lessons learned emphasize the importance of improved instrumentation strategies, iterative wave tank tuning, more precisely manufactured scaled mooring components, and enhanced anchoring systems to reduce experimental uncertainty.

16 TIDAL AND WAVE POWER↗

NASA'S reliability requirements.

NASA reliability program provisions for space system contractors, detailing program management, reliability engineering, testing and evaluation

PROGRAM MANAGEMENT↗

Reliability Assessment of Cooling Fans for PV Inverters: Testing, Modeling, and Case Studies

The reliability of photovoltaic (PV) inverters is critical for long-term solar system performance, with cooling fan failures frequently leading to costly downtime. While much research exists on general cooling fan reliability, little attention has been given to fans operating within PV inverters and their unique environmental challenges. Here, this article proposes a comprehensive methodology to address this gap. First, a failure mode and effects analysis is performed on fans to identify the key failure mechanisms in PV applications, their corresponding stressors, and the models necessary for lifetime prediction. Second, an accelerated life test is designed and conducted to collect valuable experimental data for PV inverter fans in a reasonable amount of time. Third, a mathematical conversion of dynamic mission profiles into effective constant stress levels is derived. Fourth, case studies are given, showcasing lifetime estimates that account for geographic variations in mission profile data. The results demonstrate that this integrated approach leads to an accurate reliability assessment for PV inverter cooling fans.

accelerated life testing (ALT)↗

Failure analysis of electronic parts: Laboratory methods

Failure analysis test methods are presented for use in analyzing candidate electronic parts and in improving future design reliability. Each test is classified as nondestructive, semidestructive, or destructive. The effects upon applicable part types (i.e. integrated circuit, transitor) are discussed. Methodology is given for performing the following: immersion tests, radio graphic tests, dewpoint tests, gas ambient analysis, cross sectioning, and ultraviolet examination.

Anstead, R. J.↗

NASA-DoD Lead-Free Electronics Project: Vibration Test

Vibration testing was conducted by Boeing Research and Technology (Seattle) for the NASA-DoD Lead-Free Electronics Solder Project. This project is a follow-on to the Joint Council on Aging Aircraft/Joint Group on Pollution Prevention (JCAA/JG-PP) Lead-Free Solder Project which was the first group to test the reliability of lead-free solder joints against the requirements of the aerospace/miLItary community. Twenty seven test vehicles were subjected to the vibration test conditions (in two batches). The random vibration Power Spectral Density (PSD) input was increased during the test every 60 minutes in an effort to fail as many components as possible within the time allotted for the test. The solder joints on the components were electrically monitored using event detectors and any solder joint failures were recorded on a Labview-based data collection system. The number of test minutes required to fail a given component attached with SnPb solder was then compared to the number of test minutes required to fail the same component attached with lead-free solder. A complete modal analysis was conducted on one test vehicle using a laser vibrometer system which measured velocities, accelerations, and displacements at one . hundred points. The laser vibrometer data was used to determine the frequencies of the major modes of the test vehicle and the shapes of the modes. In addition, laser vibrometer data collected during the vibration test was used to calculate the strains generated by the first mode (using custom software). After completion of the testing, all of the test vehicles were visually inspected and cross sections were made. Broken component leads and other unwanted failure modes were documented.

Woodrow, Thomas A.↗

Rapid Electrochemical Diagnosis of Battery Health and Safety from Cells to Modules

Rapid electrochemical diagnosis of battery health and failure is critical for ensuring reliable battery performance and battery safety. Traditional battery health diagnostics such as capacity measurements and DC pulse tests are reliable and well-understood, however, these measurements of battery capacity and resistance do not capture all aspects of battery degradation. Other aspects of degradation, such as electrolyte decomposition, lithium-plating, and particle cracking are difficult to detect electrochemically but are crucial to measure to get a full picture of battery safety and flag out potential failures. In this work, lab- and field-aged commercial lithium-ion batteries and modules of various chemistries and formats are tested using a variety of traditional electrochemical characterization methods as well as using 2-minute pseudo-random DC pulse sequences at rest and during charge/discharge. The electrochemical measurements are compared to physical cell measurements, cell efficiency, drive cycle performance, physical and thermal heterogeneity, and qualitative safety metrics using statistical and machine-learning methods to discover if a comprehensive "battery health map" can be accurately identified using only rapid DC measurements.

ADVANCED PROPULSION SYSTEMS,ENERGY STORAGE↗

Reliability of Upright and Supine Power Measurements Using an Inertial Load Cycle Ergometer

Practical, reliable, and time efficient methods of measuring muscular power are desirable for both research and applied testing situations. The inertial-load cycling method (ILC; Power/Cycle, Austin, TX) requires subjects to pedal as fast as possible against the inertial load of a flywheel for only 3-5 seconds, which could help reduce the time and effort required for maximal power testing. PURPOSE: 1) To test the intramachine reliability of ILC over 3 separate sessions, 2) to compare postural stance (upright vs. supine) during testing, and 3) to compare the maximal power (Pmax) output measured using ILC to that obtained from traditional isokinetic and leg press testing. METHODS: Subjects (n = 12) were tested on 4 non-consecutive days. The following tests were done on the first day of testing: isometric knee extension, isokinetic knee extension at several speeds, isokinetic power/endurance at 180/sec (Biodex System 4), leg press maximal isometric force, and leg press power/endurance. The other 3 days consisted exclusively of ILC testing. Subjects performed 6 ILC tests in an upright position and 6 ILC tests in a supine position on each day. The starting position was counterbalanced. Mixed-effects linear modeling was used to determine if any differences existed between testing days and between upright and supine for Pmax and revolutions per minute at Pmax (RPMpk). Mixed-modeling was also used to calculate intraclass correlation coefficients (ICC) to determine the reliability of the ILC on each testing day for Pmax and RPMpk (ICCs were calculated separately for upright and supine). gKendall fs Tau a h was used to determine the association between ILC Pmax and isokinetic and leg press data. RESULTS: For Pmax, significant differences were found between days 1 and 2 (upright: p = 0.018; supine: p = 0.014) and between days 1 and 3 (upright: p = 0.001; supine: p = 0.002), but not between days 2 and 3 (upright: p = 0.422; supine: p = 0.501). Pmax ICC values were greater than or equal to 0.97 for all days in both positions. Also, no significant differences between upright and supine postures were found for Pmax. No significant differences between days were found for RPMpk; however, there was a significant posture effect (upright greater than supine). Moderate correlations were observed between ILC Pmax and isokinetic and leg press tests (upright: 0.64-0.79, supine: 0.52-0.82). CONCLUSIONS: Overall, ILC is a very reliable test. Since a significant difference was found between day 1 and the other ILC testing days, it is suggested that day 1 of ILC testing should be used as a familiarization session to allow for subject learning. No significant difference in Pmax was seen from test 3 to test 6. However, an increase of 1.3% was observed from test 4 to test 6. Therefore, although 4 tests may be sufficient for most subjects to produce Pmax, in some cases 6 tests may be required. PRACTICAL APPLICATIONS: No differences were seen in Pmax between upright and supine positions despite differing RPMpk. This suggests that ILC testing can be used to provide reliable testing both in an upright position (appropriate for athletes) and in research (e.g., bed rest) or rehabilitation settings where supine testing is necessary. Future research should evaluate whether peak power measurements obtained with the ILC are sensitive to changes such as that observed with training and de-training.

Wickwire, P. J.↗

A new Role of Proficiency Testing in Nuclear Analytical Work

The most recent definition of measurement result requires a statement of uncertainty whenever results obtained by nuclear or other quantitative methods of analysis are reported. Proficiency testing (PT) therefore must include the ability of laboratories to present not only unbiased quantity values, but reliable estimates of their uncertainty. Hence, a reference value with the smallest possible uncertainty is needed to ascertain the proficiency of laboratories reporting results with lower than average uncertainty. A strategy based on the T-statistic is proposed leading to an accepted reference value that fully reflects the uncertainties reported by participants in a PT-scheme and permits calculation of En numbers to distinguish whether or not measurement results are consistent with the accepted definition of the measurand. The strategy is applied to PT-data from a recent international laboratory intercomparison of uranium isotopic ratios with very low reported uncertainties. In the paper this example is used to present the situation in the nuclear field.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Hourglass Sampling of Participants in the Human Reliability Program (HRP) for Drug and Alcohol (D&A) Testing

Hourglass Sampling of Participants in the Human Reliability Program (HRP) for Alcohol and Drug Testing Ivan R. Thomas Idaho National Laboratory The random sampling with replacement of Human Reliability Program (HRP) participants for alcohol and drug testing can have the disadvantage that some participants are selected multiple times while others might not be chosen during an annual testing period. To alleviate this inefficiency, an “hourglass” sampling scheme has been developed at the Idaho National Laboratory for the random selection of HRP participants. With this scheme, all HRP participants are placed in a primary population at the beginning of the calendar year, and throughout the year, sequential random samples (generally of a fixed sample size) are drawn without replacement until the population is emptied. Thus, each participant is guaranteed to be tested at least once annually; but due to the random selection, the time of the initial test is unknown. After initial testing, the participants drawn from the primary population are transferred to a secondary population for potential retesting. Each time that the primary population is sampled, the secondary population is likewise sampled, but the sampling is with replacement. Thus, while the primary population decreases at a constant rate, the secondary population increases at the same rate through the accrual and retention of previously-tested participants, hence the hourglass concept. The replacement sampling of participants from the secondary population is through an increasing sample size (a fixed percentage of those currently in the population). Thus, once in the secondary population, each participant has a constant probability of being reselected, but the number of annual reselections is less than would be realized through traditional replacement sampling from a single population. Furthermore, the objective of maintaining suspense on the part of the HRP participant is retained, that is, all participants, whether or not initially picked from the primary population or reselected from the secondary population, always anticipate a future selection.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Progress in development of pulsed resonant charging power supply for the Spallation Neutron Source extraction kicker PFN system

A conceptual design of the pulsed resonant charging power supply (RCPS) for the beam extraction system of the Spallation Neutron Source (SNS) at the Oak Ridge National Laboratory (ORNL) was previously reported at the 2019 IEEE Pulsed Power & Plasma Science Conference (PPPS 2019) [1]. Development and testing of the prototype supply continued through the year to finalize the design ahead of the Proton Power Upgrade (PPU). Testing revealed reliability issues with the original resonant charging scheme related to the step-up transformer core. Additional components were incorporated into the system, and some of the original prototype components were replaced to improve performance and reliability of the power supply. This paper describes the changes in the resonant charging scheme, presents the results of testing of the improved prototype at full power level, and shows the final design of the RCPS.

Peplov, Vladimir↗

The scaling of model test results to predict intake hot gas reingestion for STOVL aircraft with augmented vectored thrust engines

The difficulties of modeling the complex recirculating flow fields produced by multiple jet STOVL aircraft close to the ground have led to extensive use of experimental model tests to predict intake Hot Gas Reingestion (HGR). Model test results reliability is dependent on a satisfactory set of scaling rules which must be validated by fully comparable full scale tests. Scaling rules devised in the U.K. in the mid 60's gave good model/full scale agreement for the BAe P1127 aircraft. Until recently no opportunity has occurred to check the applicability of the rules to the high energy exhaust of current ASTOVL aircraft projects. Such an opportunity has arisen following tests on a Tethered Harrier. Comparison of this full scale data and results from tests on a model configuration approximating to the full scale aircraft geometry has shown discrepancies between HGR levels. These discrepancies although probably due to geometry and other model/scale differences indicate some reexamination of the scaling rules is needed. Therefore the scaling rules are reviewed, further scaling studies planned are described and potential areas for further work are suggested.

Penrose, C. J.↗

CALiPER Exploratory Study: Accounting for Uncertainty in Lumen Measurements

With a well-defined and shared understanding of uncertainty in lumen measurements, testing laboratories can better evaluate their processes, contributing to greater consistency and credibility of lighting testing a key component of the U.S. Department of Energy (DOE) Commercially Available LED Product Evaluation and Reporting (CALiPER) program. Reliable lighting testing is a crucial underlying factor contributing toward the success of many energy-efficient lighting efforts, such as the DOE GATEWAY demonstrations, Lighting Facts Label, ENERGY STAR® energy efficient lighting programs, and many others. Uncertainty in measurements is inherent to all testing methodologies, including photometric and other lighting-related testing. Uncertainty exists for all equipment, processes, and systems of measurement in individual as well as combined ways. A major issue with testing and the resulting accuracy of the tests is the uncertainty of the complete process. Individual equipment uncertainties are typically identified, but their relative value in practice and their combined value with other equipment and processes in the same test are elusive concepts, particularly for complex types of testing such as photometry. The total combined uncertainty of a measurement result is important for repeatable and comparative measurements for light emitting diode (LED) products in comparison with other technologies as well as competing products. This study provides a detailed and step-by-step method for determining uncertainty in lumen measurements, working closely with related standards efforts and key industry experts. This report uses the structure proposed in the Guide to Uncertainty Measurements (GUM) for evaluating and expressing uncertainty in measurements. The steps of the procedure are described and a spreadsheet format adapted for integrating sphere and goniophotometric uncertainty measurements is provided for entering parameters, ordering the information, calculating intermediate values and, finally, obtaining expanded uncertainties. Using this basis and examining each step of the photometric measurement and calibration methods, mathematical uncertainty models are developed. Determination of estimated values of input variables is discussed. Guidance is provided for the evaluation of the standard uncertainties of each input estimate, covariances associated with input estimates and the calculation of the result measurements. With this basis, the combined uncertainty of the measurement results and finally, the expanded uncertainty can be determined.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗