Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Reads”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

Extracting the Data From the LCM vk4 Formatted Output File

These are slides about extracting the data from the LCM vk4 formatted output file. The following is covered: vk4 file produced by Keyence VK Software, custom analysis, no off the shelf way to read the file, reading the binary data in a vk4 file, various offsets in decimal lines, finding the height image data, directly in MATLAB, binary output beginning of height image data, color image information, color image binary data, color image decimal and binary data, MATLAB code to read vk4 file (choose a file, read the file, compute offsets, read optical image, laser optical image, read and compute laser intensity image, read height image, timing, display height image, display laser intensity image, display RGB laser optical images, display RGB optical images, display beginning data and save images to workspace, gamma correction subroutine), reading intensity form the vk4 file, linear in the low range, linear in the high range, gamma correction for vk4 files, computing the gamma intensity correction, observations.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

CMS Storage Performance with RNTuple

CMS is transitioning to use ROOT’s new RNTuple data storage format for the files CMS will write in the HL-LHC era. Based on initial tests, CMS expects faster I/O and smaller files compared to the present TTree storage format. This contribution will show a comprehensive performance comparison between RNTuple and TTree I/O using CMS AOD and MiniAOD data formats as test cases for both simulation and collision data corresponding to similar data taking conditions of LHC Run 3. Quantities such as the resulting file size, the memory usage of the I/O components, and the rate of events being read from a file or written to a file will be measured. CMS’ data processing relies heavily on reading files over the local or wide area networks. The file read patterns are important because the latencies have been seen to influence the total production job times. Therefore a study on the file read patterns will be conducted by recording traces of the offset, size, and timestamp of each read request for both RNTuple and TTree. The behavior of network reads will be mimicked by reading local files where artificial latency will be added to the read requests. The effect of different latency values on the job times will be studied.

Jones, Christopher D. [Fermilab]↗

Multisensor Arrays for Greater Reliability and Accuracy

Arrays of multiple, nominally identical sensors with sensor-output-processing electronic hardware and software are being developed in order to obtain accuracy, reliability, and lifetime greater than those of single sensors. The conceptual basis of this development lies in the statistical behavior of multiple sensors and a multisensor-array (MSA) algorithm that exploits that behavior. In addition, advances in microelectromechanical systems (MEMS) and integrated circuits are exploited. A typical sensor unit according to this concept includes multiple MEMS sensors and sensor-readout circuitry fabricated together on a single chip and packaged compactly with a microprocessor that performs several functions, including execution of the MSA algorithm. In the MSA algorithm, the readings from all the sensors in an array at a given instant of time are compared and the reliability of each sensor is quantified. This comparison of readings and quantification of reliabilities involves the calculation of the ratio between every sensor reading and every other sensor reading, plus calculation of the sum of all such ratios. Then one output reading for the given instant of time is computed as a weighted average of the readings of all the sensors. In this computation, the weight for each sensor is the aforementioned value used to quantify its reliability. In an optional variant of the MSA algorithm that can be implemented easily, a running sum of the reliability value for each sensor at previous time steps as well as at the present time step is used as the weight of the sensor in calculating the weighted average at the present time step. In this variant, the weight of a sensor that continually fails gradually decreases, so that eventually, its influence over the output reading becomes minimal: In effect, the sensor system "learns" which sensors to trust and which not to trust. The MSA algorithm incorporates a criterion for deciding whether there remain enough sensor readings that approximate each other sufficiently closely to constitute a majority for the purpose of quantifying reliability. This criterion is, simply, that if there do not exist at least three sensors having weights greater than a prescribed minimum acceptable value, then the array as a whole is deemed to have failed.

Immer, Christopher↗

PMU Data Integrity Evaluation through Analytics on a Virtual Test-Bed

Power systems are rapidly becoming populated by phasor measurement units (PMUs) in ever increasing numbers. PMUs are critical components of today s energy management systems, designed to enable near real-time wide area monitoring and control of the electric power system. They are able to measure highly accurate bus voltage phasors as well as branch current phasors incident to the buses at which PMUs are equipped. Synchrophasor data is used for applications varying from state estimation, islanding control, identifying outages, voltage stability detection and correction, disturbance recording, and others. However, PMU-measured readings may suffer from errors due to meter biases or drifts, incorrect configurations, or even cyber-attacks. Furthermore, the testing of early PMUs showed a large disparity between the reported values from PMUs provided by different manufacturers, particularly when frequency was off-nominal, during dynamic events, and when harmonic/inter-harmonic content was present. Detection and identification of PMU gross measurement errors are thus crucial in maintaining highly accurate phasor readings throughout the system. In this paper, we present our work in conducting analytics to determine the trustworthiness and worth of the PMU readings collected across an electric network system. By implementing the IEEE 118 bus test case on a virtual test bed (VTB) , we are able to emulate PMU readings (bus voltage and branch current phasors in addition to bus frequencies) under normal and abnormal conditions using (virtual) PMU sensors deployed across major substations in the network. We emulate a variety of failures such as bus, line, transformer, generator, and/or load failures. Data analytics on the voltage phase angles and frequencies collected from the PMUs show that specious (or compromised) PMU device(s) can be identified through abnormal behaviour by comparing the trend of its frequency and phase angle reading with the ensemble of all other PMU readings in the network. If the reading trend of a particular PMU deviates from the weighted average of the reading trends of other PMUs at nearby substations, then it is likely that the PMU is malfunctioning. We assign a weight to each PMU denoting how electric-topology-wise close it is from where the PMU under consideration is located. The closer a PMU is, the higher the weight it has. To compute the closeness between two nodes in the power network, we employ a form of the resistance distance metric. It computes the electrical distance by taking into consideration the underlying topology as well as the physical laws that govern the electrical connections or flows between the network components. The detection accuracy of erroneous PMUs should be improved by employing this metric. We present results to validate the proposed approach. We also discuss the effectiveness of using an end-to-end VTB approach that allows us to investigate different types of failures and their responses as seen by the ensemble of PMUs. The collected data on certain types of events may be amenable to certain types of analysis (e.g., alerting for sudden changes can be done on a small window of data) and hence determine the data analytics architectures is required to evaluate the streaming PMU data.

and data analytics architecture.↗

Telomere-to-telomere assemblies of chromosome 10 reveal complex adaptive variation of 3-ketoacyl-CoA-synthases in Populus trichocarpa likely driven by Helitrons

The model woody plant Populus trichocarpa displays an atypical alkene-diverse wax cuticle likely driven by copy number variation (CNV) of 3-ketoacyl-CoA synthases ( KCS ), which has been difficult to confirm with short-read assemblies. Long-read sequencing enables the development of telomere-to-telomere resources to detect cryptic variation, including CNVs, which are currently missed. Integrating this information can improve genomic prediction for breeding and provide insights into the evolutionary basis of important traits. Our analysis of 78 long-read haplotypes from chromosome 10 identified more than twice as many KCS genes as previously reported, and numerous intragenic non-synonymous substitutions. Random Forest predictive models highlighted the importance of Potri.010G079500 in producing very long chain alkenes; however, its absence did not predict previously reported alkene-deficient phenotypes. Instead, alkene levels are best predicted by the combinations of KCS copies. Additionally, amino acid substitutions clustered around ligand and donor binding pockets, suggesting they contribute to differing wax cuticle composition. Finally, each KCS gene and copy was linked to a Helitron transposon. A phylogenetic analysis suggests Helitrons are the evolutionary mechanism for generating KCS tandem arrays. Long-read generated telomere-to-telomere assemblies of P. trichocarpa chromosome 10 revealed large-effect loci critical to genetic studies that are unattainable from short-reads. This new resource produced novel insights into genome structure and function, and a novel mechanism for generating tandem gene duplication. Our results highlight that, given current challenges in annotation and assembly, detailed and focused long-read sequences are key to interpreting complex genomic regions that contain tandem copy number variants.

09 BIOMASS FUELS↗

Assembly of Repeat Content Using Next Generation Sequencing Data

Repetitive organisms pose a challenge for short read assembly, and typically only unique regions and repeat regions shorter than the read length, can be accurately assembled. Recently, we have been investigating the use of Pacific Biosciences reads for de novo fungal assembly. We will present an assessment of the quality and degree of repeat reconstruction possible in a fungal genome using long read technology. We will also compare differences in assembly of repeat content using short read and long read technology.

09 BIOMASS FUELS↗

Fault detection and analysis in nuclear research facility using artificial intelligence methods

In this article, an online detection of transducer and actuator condition is discussed. A case study is on the reading of area radiation monitor (ARM) installed at the chimney of PUSPATI TRIGA nuclear reactor building, located at Bangi, Malaysia. There are at least five categories of abnormal ARM reading that could happen during the transducer failure, namely either the reading becomes very high, or very low/ zero, or with high fluctuation and noise. Moreover, the reading may be significantly higher or significantly lower as compared to the normal reading. An artificial neural network (ANN) and adaptive neuro-fuzzy inference system (ANFIS) are good methods for modeling this plant dynamics. The failure of equipment is based on ARM reading so it is then to compare with the estimated ARM data from ANN/ ANFIS function. The failure categories in either ‘yes’ or ‘no’ state are obtained from a comparison between the actual online data and the estimated output from ANN/ ANFIS function. It is found that this system design can correctly report the condition of ARM equipment in a simulated environment and later be implemented for online monitoring. This approach can also be extended to other transducers, such as the temperature profile of reactor core and also to include other critical actuator conditions such as the valves and pumps in the reactor facility provided that the failure symptoms are clearly defined.

42 ENGINEERING↗

CAPG: comprehensive allopolyploid genotyper

Genotyping by sequencing is a powerful tool for investigating genetic variation in plants, but many economically important plants are allopolyploids, where homoeologous similarity obscures the subgenomic origin of reads and confounds allelic and homoeologous SNPs. Recent polyploid genotyping methods use allelic frequencies, rate of heterozygosity, parental cross or other information to resolve read assignment, but good subgenomic references offer the most direct information. The typical strategy aligns reads to the joint reference, performs diploid genotyping within each subgenome, and filters the results, but persistent read misassignment results in an excess of false heterozygous calls. We introduce the Comprehensive Allopolyploid Genotyper (CAPG), which formulates an explicit likelihood to weight read alignments against both subgenomic references and genotype individual allopolyploids from whole-genome resequencing data. We demonstrate CAPG in allotetraploids, where it performs better than Genome Analysis Toolkit’s HaplotypeCaller applied to reads aligned to the combined subgenomic references.

59 BASIC BIOLOGICAL SCIENCES↗

Usage Pattern-Driven Dynamic Data Layout Reorganization

As scientific simulations and experiments move toward extremely large scales and generate massive amounts of data, the data access performance of analytic applications becomes crucial. A mismatch often happens between write and read patterns of data accesses, typically resulting in poor read performance. Data layout reorganization has been used to improve the locality of data accesses. However, current data reorganizations are static and focus on generating a single (or set of) optimized layouts that rely on prior knowledge of exact future access patterns. We propose a framework that dynamically recognizes the data usage patterns, replicates the data of interest in multiple reorganized layouts that would benefit common read patterns, and makes runtime decisions on selecting a favorable layout for a given read pattern. This framework supports reading individual elements and chunks of a multi-dimensional array of variables. Our pattern-driven layout selection strategy achieves multi-fold speedups compared to reading from the original dataset.

97 MATHEMATICS AND COMPUTING↗

Parallel programming of an ionic floating-gate memory array for scalable neuromorphic computing

Neuromorphic computers could overcome efficiency bottlenecks inherent to conventional computing through parallel programming and readout of artificial neural network weights in a crossbar memory array. However, selective and linear weight updates and <10-nanoampere read currents are required for learning that surpasses conventional computing efficiency. We introduce an ionic floating-gate memory array based on a polymer redox transistor connected to a conductive-bridge memory (CBM). Selective and linear programming of a redox transistor array is executed in parallel by overcoming the bridging threshold voltage of the CBMs. Synaptic weight readout with currents <10 nanoamperes is achieved by diluting the conductive polymer with an insulator to decrease the conductance. The redox transistors endure >1 billion write-read operations and support >1-megahertz write-read frequencies.

bio-inspired, energy storage (including batteries ↗

Rapid quantification of sequence repeats to resolve the size, structure and contents of bacterial genomes

Background: The numerous classes of repeats often impede the assembly of genome sequences from the short reads provided by new sequencing technologies. We demonstrate a simple and rapid means to ascertain the repeat structure and total size of a bacterial or archaeal genome without the need for assembly by directly analyzing the abundances of distinct k-mers among reads. Results: The sensitivity of this procedure to resolve variation within a bacterial species is demonstrated: genome sizes and repeat structure of five environmental strains of E. coli from short Illumina reads were estimated by this method, and total genome sizes corresponded well with those obtained for the same strains by pulsed-field gel electrophoresis. In addition, this approach was applied to read-sets for completed genomes and shown to be accurate over a wide range of microbial genome sizes. Conclusions: Application of these procedures, based solely on k-mer abundances in short read data sets, allows aspects of genome structure to be resolved that are not apparent from conventional short read assemblies. This knowledge of the repetitive content of genomes provides insights into genome evolution and diversity.

59 BASIC BIOLOGICAL SCIENCES↗

Validation Testing for Automated Solubility Measurement Equipment Final Report

Laboratory tests have been completed to test the validity of automated solubility measurement equipment using sodium nitrate and sodium chloride solutions (see test plan WRPS-1404441, “Validation Testing for Automated Solubility Measurement Equipment”). The sodium nitrate solution results were within 2-3% of the reference values, so the experiment is considered successful using the turbidity meter. The sodium chloride test was done by sight, as the turbidity meter did not work well using sodium chloride. For example, the “clear” turbidity reading was 53 FNU at 80 °C, 107 FNU at 55 °C, and 151 FNU at 20 °C. The sodium chloride did not work because it is granular and large; as the solution was stirred, the granules stayed to the outside of the reactor and just above the stir bar level, having little impact on the turbidity meter readings as the meter was aimed at the center of the solution. Also, the turbidity meter depth has an impact. The salt tends to remain near the stir bar level. If the meter is deeper in the slurry, it will read higher turbidity, and if the meter is raised higher in the slurry, it will read lower turbidity (possibly near zero) because it reads the “clear” part of the slurry. The sodium chloride solution results, as measured by sight rather than by turbidity instrument readings, were within 5-6% of the reference values.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Trimming and Decontamination of Metagenomic Data can Significantly Impact Assembly and Binning Metrics, Phylogenomic and Functional Analysis

Background: Investigators using metagenomic sequencing to study microbiomes often trim and decontaminate reads without knowing their effect on downstream analyses. Objective: This study was designed to evaluate the impacts JGI trimming and decontamination procedures have on assembly and binning metrics, placement of MAGs into species trees, and functional profiles of MAGs extracted from complex rhizosphere metagenomes, as well as how more aggressive trimming impacts these binning metrics. Methods: Twenty-three Miscanthus x giganteus rhizosphere metagenomes were subjected to different combinations and thresholds of force, kmer, and quality trimming and decontamination using BBDuk. Reads were assembled and binned in KBase. Phylogenomic and statistical analyses were applied to evaluate the effects of trimming and decontamination on downstream analyses. Results: We found that JGI trimmed and decontaminated reads had significant impacts on assembly and binning metrics compared to raw reads, including significantly higher total contig counts, more contigs greater than 10k bp in length, and larger total lengths of raw assemblies compared to QC assemblies, and 2.0% lower average contamination of QC MAGs compared to raw MAGs. We also found that differences in the placement of MAGs in species trees increased with decreasing completeness and contamination thresholds. Furthermore, aggressive trimming (Q20) was found to significantly reduce MAG counts. Conclusion: Trimming and decontamination of metagenomics reads prior to assembly can change an investigator’s answer to the questions, “Who is there and what are they doing?” However, mild trimming and decontamination of metagenomic reads with high-quality scores are recommended for removing sample processing and sequencing artifacts.

Whitham, Jason M.↗

JAN transistor and diode characterization test program, JANTX diode 1N5623

A statistical summary of the electrical characterization of diodes and transistors is presented. Each parameter is presented with test conditions, mean, standard deviation, lowest reading, 10% point (where 10% of all readings are equal to or less than the indicated reading), 90% point (where 90% of all readings are equal to or less than indicated reading) and the highest reading.

Takeda, H.↗

JAN transistor and diode characterization test program, JANTX diode 1N649-1

The data processing and calculation of statistical parameters was performed by the Tektronix computer system. The data acquired for easy vendor to vendor and date code to date code analysis are summarized. Each parameter is presented with test conditions, mean, standard deviation, lowest reading, 10% point (where 10% of all readings are equal to or less than the indicated reading), 90% point (where 90% of all readings are equal to or less than the indicated reading) and the highest reading.

Takeda, H.↗

Simulation and analysis of support hardware for multiple instruction rollback

Recently, a compiler-assisted approach to multiple instruction retry was developed. In this scheme, a read buffer of size 2N, where N represents the maximum instruction rollback distance, is used to resolve one type of data hazard. This hardware support helps to reduce code growth, compilation time, and some of the performance impacts associated with hazard resolution. The 2N read buffer size requirement of the compiler-assisted approach is worst case, assuring data redundancy for all data required but also providing some unnecessary redundancy. By adding extra bits in the operand field for source 1 and source 2 it becomes possible to design the read buffer to save only those values required, thus reducing the read buffer size requirement. This study measures the effect on performance of a DECstation 3100 running 10 application programs using 6 read buffer configurations at varying read buffer sizes.

Alewine, Neil J.↗

Strain Gauges Indicate Differential-CTE-Induced Failures

A method of detecting mechanical failure induced by variation in temperature at an adhesive bond between two materials that have different coefficients of thermal expansion (CTEs) involves monitoring of strain-gauge readings. This method can be regarded as an exploitation of the prior observation that the readings of strain gauges commonly used in tensile and compressive testing of material specimens include features indicative of incremental failures in the specimens. In this method, one or more strain gauges are bonded to either or both of the two materials near the bond between the materials. (The adhesive used to bond the strain gauges would not ordinarily be the same as the one used to bond the two materials). Then strain-gauge readings are recorded as the temperature of the materials is varied through a range of interest. Any significant discontinuity in the slope of the resulting strain-versus-temperature curve(s) is taken to be a qualitative indication of a failure of the bond between the two materials and/or a failure within one of the materials in the vicinity of the bond. The method has been demonstrated in experiments on specimens consisting of polyacrylonitrile-fiber/epoxy-matrix laminated composite plates bonded by epoxy to smaller plates made, variously, of aluminum, titanium, and a low-CTE nickel/iron alloy. In preparation for each experiment, strain gauges were bonded, by use of cryogenic-rated adhesives, to the composite plate near the corners of the metal plate (see Figure 1). In each experiment, strain-gauge and temperature readings were taken as the specimen was cooled from room temperature to 20 K. The specimens were then returned to room temperature and ultrasonically inspected for damage in the bond region. No failure events were detectable in the strain-gauge readings from the composite/ titanium and composite/low-thermalexpansion- alloy specimens, and ultrasonic inspection of these specimens revealed no damage. However, failure events were seen in the strain-gauge readings from the composite/aluminum specimens (see Figure 2), and ultrasonic inspection confirmed that there was damage in the bond regions of these specimens.

Harris, Brian↗