Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Readout electronics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

Towards Quantum-Limited Cryogenic Amplification for Multi-Qubit Platforms

Here we present the development of the building blocks of a Josephson parametric amplifier (JPA), namely the superconducting quantum interference device (SQUID) and the inductive pick-up coil that permits current coupling from a quantum dot into the SQUID. We also discuss our efforts in making depletion mode quantum dots using delta doped GaAs quantum wells. Because quantum dot based spin qubits utilize very low-level (~10 - 100pA), short duration (1ms - 1μs) current signals for state preparation and readout, these systems require close proximity cryogenic amplification to prevent signal corruption. Common amplification methods in these semiconductor quantum dots rely on heterojunction bipolar transistors (HBTs) and high electron mobility transistors (HEMTs) to amplify the readout signal from a single qubit. The state of the art for HBTs and HEMTs produce approximately 10µW of power when operating at high bandwidths. For few-qubit systems this level of heat dissipation is acceptable. However, for scaling up the number of qubits to several hundred or a thousand, the heat load produced in a 1 to 1 amplifier to qubit arrangement would overload the cooling capacity of a common dilution refrigerator, which typically has a cooling power of ~100µW at its base temperature. Josephson parametric amplifiers have been shown to dissipate ~1pW of power with current sensitivies on par with HBTs and HEMTs and with bandwidths 30 times that of HBTs and HEMTs, making them attractive for multi-qubit platforms. In this report we describe in detail the fabrication process flow for developing inductive pick-up coils and the fabrication and measurement of NbTiN and A1/A1Ox/A1 SQUIDs.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

3D reconstruction of nuclear reactions using GEM TPC with planar readout

The research program of the Extreme Light Infrastructure – Nuclear Physics (ELI-NP) laboratory under construction in Magurele, Romania facilities the need of developing a gaseous active-target detector providing 3D reconstruction of charged products of nuclear reactions induced by gamma beam. The monoenergetic, high-energy (E{sub γ} > 19 MeV) gamma beam of intensity 10{sup 13}γ/s allows studying nuclear reactions in astrophysics. A Time Projection Chamber with crossed strip readout (eTPC) is proposed as one of the imaging detectors. The special feature of the readout electrode structure is a 2D reconstruction based on the information read out simultaneously from three arrays of strips that form virtual pixels. It is expected to reach similar spatial resolution as for pixel readout at largely reduced cost of electronics. The paper presents the current progress and first results of the small scale prototype TPC which is a one of implementation steps towards eTPC detector proposed in the Technical Design Report of Charged Particles Detection at ELI-NP.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

An FPGA-based readout chip emulator for the CMS ETL detector upgrade

Here, we present an FPGA-based readout chip emulator board for the CMS Endcap Timing Layer (ETL) detector upgrade. The emulator board uses an Intel Cyclone 10 GX FPGA to emulate the digital functions of four Endcap Layer Readout Chips (ETROCs). Based on the actual ETROC design, the firmware is implemented and verified. The emulator board is being used for the ETROC digital design verification and system development.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Evaluation of a lithium formate EPR dosimetry system for dose measurements around {sup 192}Ir brachytherapy sources

A dosimetry system using lithium formate monohydrate (HCO{sub 2}Li{center_dot}H{sub 2}O) as detector material and electron paramagnetic resonance (EPR) spectroscopy for readout has been used to measure absorbed dose distributions around clinical {sup 192}Ir sources. Cylindrical tablets with diameter of 4.5 mm, height of 4.8 mm, and density of 1.26 g/cm{sup 3} were manufactured. Homogeneity test and calibration of the dosimeters were performed in a 6 MV photon beam. {sup 192}Ir irradiations were performed in a PMMA phantom using two different source models, the GammaMed Plus HDR and the microSelectron PDR-v1 model. Measured absorbed doses to water in the PMMA phantom were converted to the corresponding absorbed doses to water in water phantoms of dimensions used by the treatment planning systems (TPSs) using correction factors explicitly derived for this experiment. Experimentally determined absorbed doses agreed with the absorbed doses to water calculated by the TPS to within {+-}2.9%. Relative standard uncertainties in the experimentally determined absorbed doses were estimated to be within the range of 1.7%-1.3% depending on the radial distance from the source, the type of source (HDR or PDR), and the particular absorbed doses used. This work shows that a lithium formate dosimetry system is well suited for measurements of absorbed dose to water around clinical HDR and PDR {sup 192}Ir sources. Being less energy dependent than the commonly used thermoluminescent lithium fluoride (LiF) dosimeters, lithium formate monohydrate dosimeters are well suited to measure absorbed doses in situations where the energy dependence cannot easily be accounted for such as in multiple-source irradiations to verify treatment plans. Their wide dynamic range and linear dose response over the dose interval of 0.2-1000 Gy make them suitable for measurements on sources of the strengths used in clinical applications. The dosimeter size needs, however, to be reduced for application to single-source dosimetry.

61 RADIATION PROTECTION AND DOSIMETRY↗

The New Small Wheel electronics

The increase in luminosity, and consequent higher backgrounds, of the LHC upgrades require improved rejection of fake tracks in the forward region of the ATLAS Muon Spectrometer. The New Small Wheel upgrade of the Muon Spectrometer aims to reduce the large background of fake triggers from track segments that don't originate from the interaction point. The New Small Wheel employs two detector technologies, the resistive strip Micromegas detectors and the “small” Thin Gap Chambers, with a total of 2.45 million electrodes to be sensed. The two technologies require the design of a complex electronics system given that it consists of two different detector technologies and is required to provide both precision readout and a fast trigger. It will operate in a high background radiation region up to about 20 kHz/cm 2 at the expected HL-LHC luminosity of $\mathcal{L}$= 7.5 × 10 34 cm -2 s -1 . The architecture of the system is strongly defined by the GBTx data aggregation ASIC, the newly-introduced FELIX data router and the software based data handler of the ATLAS detector. The electronics complex of this new detector was designed and developed in the last ten years and consists of multiple radiation tolerant Application Specific Integrated Circuits, multiple front-end boards, dense boards with FPGA's and purpose-built Trigger Processor boards within the ATCA standard. The New Small Wheel has been installed in 2021 and is undergoing integration within ATLAS for LHC Run 3. It should operate through the end of Run 4 (December 2032). In this manuscript, the overall design of the New Small Wheel electronics is presented.

47 OTHER INSTRUMENTATION↗

Dosimetric property of mineral extracted from calamari and exposed to gamma rays

Dosimetric property of polymineral fraction, quartz mainly, obtained from calamari was investigated. The commercial calamari samples from China and Sud Africa were collected in the markets of Italy. All polymineral debris were extracted and isolated from the whole body of calamari. The surface of the polymineral samples was analyzed by using the Scanning Electron Microscopy (SEM) and their chemical composition was determined using Energy Dispersive Spectroscopy (EDS). The polymineral was exposed to gamma rays ({sup 60}Co) at different doses (0.5-80 Gy) to determine dosimetric property. Thermoluminescent (TL) glow curves showed two peaks centered at around 98-100 Degree-Sign C and 128-138 Degree-Sign C temperature range. The glow curves have been analyzed by using a deconvolution program. A linear dose response between 0.5 to 20 Gy was observed. The TL response of the samples as a function of the time storage, fading, presented a reduction of about 36-40 % at the end of 24 h. The reproducibility of the TL response after ten cycles of irradiation-readout showed an acceptable standard deviation in dosimetry. The polimineral fraction obtained from calamari shows an interesting dosimetric property and it may be useful for dosimetry in gamma radiation field.

36 MATERIALS SCIENCE↗

Spectator Proton Detection and Reconstruction in Deep Inelastic D(E,EPS) Scattering

A Radial Time Projection Chamber (RTPC) was designed and installed in Jefferson Lab's Hall B as part of the BONuS12 (Barely Off-shell Nucleon Structure) experiment. The goal of BONuS12 is to accurately measure the structure function of the neutron by scattering 11 GeV electrons and detecting them with the CLAS12 spectrometer. Deuterium gas was used as an effective neutron target, and the new RTPC was used to detect low momentum spectator protons. Protons follow a curved path in the 5 Tesla solenoid that is part of CLAS12, ionizing the He-CO2 gas in an annular drift region surrounding the target. These ionization electrons are radially drifted outwards, amplified using cylindrical GEM (Gaseous Electron Multiplication) foils and recorded using readout pads located along the entire outer face of the cylindrical detector. The particle track reconstruction software discussed in detail in this thesis uses the signals from these pads to build tracks, which are reconstructed into the drift region using the arrival times of the signals and the positions of the pads. The proton momentum is measured from the track?s curvature and thus used to extract information about the struck neutron. This thesis introduces the theory of spectator tagging as an effective strategy for measuring neutron structure, by minimizing nuclear effects in the absence of a free neutron target. Along with discussing the many detectors that make up the CLAS12 spectrometer, the RTPC will be covered in detail, along with the tracking software designed to interpret the electronic signals to rebuild the low-momentum particle tracks, and fit them to extract the relevant kinematics. The results of the software, and preliminary analysis will be shown in the final chapter, as well as the discussion of possible improvements which could be made to the tracking software.

Payette, David↗

Astronomical Spectroscopy with Skipper CCDs: First Results from a Skipper CCD Focal Plane Prototype at SIFS

We present the first on-sky results from an ultra-low-readout-noise Skipper CCD focal plane prototype for the SOAR Integral Field Spectrograph (SIFS). The Skipper CCD focal plane consists of four 6k x 1k, 15 $\mu$m pixel, fully-depleted, p-channel devices that have been thinned to ~250 $\mu$m, backside processed, and treated with an anti-reflective coating. These Skipper CCDs were configured for astronomical spectroscopy, i.e., single-sample readout noise < 4.3 e- rms/pixel, the ability to achieve multi-sample readout noise $\ll$ 1 e- rms/pixel, full-well capacities ~40,000-65,000 e-, low dark current and charge transfer inefficiency (~2 x 10$^{-4}$ e-/pixel/s and 3.44 x 10$^{-7}$, respectively), and an absolute quantum efficiency of $\gtrsim$ 80% between 450 nm and 980 nm ($\gtrsim$ 90% between 600 nm and 900 nm). We optimized the readout sequence timing to achieve sub-electron noise (~0.5 e- rms/pixel) in a region of 2k x 4k pixels and photon-counting noise (~0.22 e- rms/pixel) in a region of 220 x 4k pixels, each with a readout time of $\lesssim$ 17 min. We observed two quasars (HB89 1159+123 and QSO J1621-0042) at redshift z ~ 3.5, two high-redshift galaxy clusters (CL J1001+0220 and SPT-CL J2040-4451), an emission line galaxy at z = 0.3239, a candidate member star of the Bo\"{o}tes II ultra-faint dwarf galaxy, and five CALSPEC spectrophotometric standard stars (HD074000, HD60753, HD106252, HD101452, HD200654). We present charge-quantized, photon-counting observations of the quasar HB89 1159+123 and show the detector sensitivity increase for faint spectral features. We demonstrate signal-to-noise performance improvements for SIFS observations in the low-background, readout-noise-dominated regime. We outline scientific studies that will leverage the SIFS-Skipper CCD data and new detector architectures that utilize the Skipper floating gate amplifier with faster readout times.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Spatial and temporal evaluations of the liquid argon purity in ProtoDUNE-SP

Liquid argon time projection chambers (LArTPCs) rely on highly pure argon to ensure that ionization electrons produced by charged particles reach readout arrays. ProtoDUNE Single-Phase (ProtoDUNE-SP) was an approximately 700-ton liquid argon detector intended to prototype the Deep Underground Neutrino Experiment (DUNE) Far Detector Horizontal Drift module. It contains two drift volumes bisected by the cathode plane assembly, which is biased to create an almost uniform electric field in both volumes. The DUNE Far Detector modules must have robust cryogenic systems capable of filtering argon and supplying the TPC with clean liquid. This paper will explore comparisons of the argon purity measured by the purity monitors with those measured using muons in the TPC from October 2018 to November 2018. A new method is introduced to measure the liquid argon purity in the TPC using muons crossing both drift volumes of ProtoDUNE-SP. For extended periods on the timescale of weeks, the drift electron lifetime was measured to be above 30 ms using both systems. A particular focus will be placed on the measured purity of argon as a function of position in the detector.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

RD53A: A large-scale prototype chip for the phase II upgrade in the serially powered HL-LHC pixel detectors

The phase II upgrade of the HL-LHC experiments within the LHC intends to deepen the studies of the Higgs boson and to allow the discovery of further particles by adding an integrated luminosity of about 4000 fb -1 over 10 years of operation. This upgrade would overwhelm the installed pixel detector readout chips with higher hit rates and radiation levels than ever before. To match these extreme requirements the RD53 collaboration, a joint effort between ATLAS and CMS, developed RD53A, a new generation pixel detector readout chip prototype manufactured in a 65 nm CMOS technology. It is half the size of the final pixel chips and designed to meet requirements in the face of 3 GHz/cm 2 hit rate after irradiation to 500 Mrad. The detector is able to use 50×50 μm 2 or 25×100 μm 2 pixels with high readout speed of up to 4 links per chip with 1.28 Gbit/s each. Shunt–LDO regulators integrated on the bottom of the chip provide the required voltages to the two power domains, analog and digital. These regulators enable serial powering of the pixel modules, which is the only feasible, radiation hard scheme to ensure acceptable power cable losses and to stay within the material budget for the future pixel detectors. Finally, an overview of the status and challenges of serial powering and the Shunt–LDO regulator development will be given.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Domain walls riding the wave.

Recent years have witnessed a rapid proliferation of electronic gadgets around the world. These devices are used for both communication and entertainment, and it is a fact that they account for a growing portion of household energy consumption and overall world consumption of electricity. Increasing the energy efficiency of these devices could have a far greater and immediate impact than a gradual switch to renewable energy sources. The advances in the area of spintronics are therefore very important, as gadgets are mostly comprised of memory and logic elements. Recent developments in controlled manipulation of magnetic domains in ferromagnet nanostructures have opened opportunities for novel device architectures. This new class of memories and logic gates could soon power millions of consumer electronic devices. The attractiveness of using domain-wall motion in electronics is due to its inherent reliability (no mechanical moving parts), scalability (3D scalable architectures such as in racetrack memory), and nonvolatility (retains information in the absence of power). The remaining obstacles in widespread use of 'racetrack-type' elements are the speed and the energy dissipation during the manipulation of domain walls. In their recent contribution to Physical Review Letters, Oleg Tretiakov, Yang Liu, and Artem Abanov from Texas A&M University in College Station, provide a theoretical description of domain-wall motion in nanoscale ferromagnets due to the spin-polarized currents. They find exact conditions for time-dependent resonant domain-wall movement, which could speed up the motion of domain walls while minimizing Ohmic losses. Movement of domain walls in ferromagnetic nanowires can be achieved by application of external magnetic fields or by passing a spin-polarized current through the nanowire itself. On the other hand, the readout of the domain state is done by measuring the resistance of the wire. Therefore, passing current through the ferromagnetic wire is the preferred method, as it combines manipulation and readout of the domain-wall state. The electrons that take part in the process of readout and manipulation of the domain-wall structure in the nanowire do so through the so-called spin transfer torque: When spin-polarized electrons in the ferromagnet nanowire pass through the domain wall they experience a nonuniform magnetization, and they try to align their spins with the local magnetic moments. The force that the electrons experience has a reaction force counterpart that 'pushes' the local magnetic moments, resulting in movement of the domain wall in the direction of the electron flow through the spin-transfer torque. The forces between the electrons and the local magnetic moments in the ferromagnet also create additional electrical resistance for the electrons passing through the domain wall. By measuring resistance across a segment of the nanowire, one determines if a domain wall is present; i.e., one can read the stored information. The interaction of the spin-polarized electrons with the domain wall in the ferromagnetic nanowire is not very efficient. Even for materials achieving high polarization of the free electrons, it is very difficult to move the magnetic domain wall. Several factors contribute to this problem, with imperfections of the ferromagnetic nanowire that cause domain-wall pinning being the dominant one. Permalloy nanowires, one of the best candidates for domain-wall-based memory and logic devices, require current densities of the order of 10{sup 8} A/cm{sup 2} in order to move a domain wall from a pinning well. Considering that this current has to pass through a relatively long wire, it is not very difficult to imagine that most of the energy will go to Joule heating. The efficiency of the process - the ratio of the energy converted to domain-wall motion to the total energy consumed - is comparable to that of an incandescent light bulb converting electricity to light. A step towards more efficient domain-wall-based memory devices is the advance of using alternating currents or current pulses to drive the domain walls. Injection of a spin-polarized current below the threshold value necessary to move the domain wall only causes oscillation of the domain wall inside the pinning potential. Exploiting the effect of resonance, one can apply a specific current waveform to drive the oscillations of the domain wall into resonance. Resonant amplification of domain-wall oscillations will free the domain wall from the pinning well at current levels that are a fraction of the dc threshold. Currents of an order of magnitude lower than before were shown to be sufficient to manipulate domain walls, thus reducing Joule heating 100 times. In their current paper, Tretiakov et al. provide a theoretical basis for the mechanism of resonant domain-wall motion in ferromagnetic nanowires.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

A comparison of the neutron detection efficiency and response characteristics of two pixelated PSD-capable organic scintillator detectors with different photo-detection readout methods

Here, we characterize the performance of two pixelated neutron detectors: a PMT-based array that utilizes Anger logic for pixel identification and a SiPM-based array that employs individual pixel readout. The SiPM-based array offers improved performance over the previously developed PMT-based detector both in terms of uniformity and neutron detection efficiency. Each detector array uses PSD-capable plastic scintillator as a detection medium. We describe the calibration and neutron efficiency measurement of both detectors using a 137 Cs source for energy calibration and a 252 Cf source for calibration of the neutron response. We find that the intrinsic neutron detection efficiency of the SiPM-based array is (30.2 ± 0.9)%, which is almost twice that of the PMT-based array, which we measure to be (16.9 ± 0.1)%.

47 OTHER INSTRUMENTATION↗

The high dynamic range pixel array detector (HDR-PAD): Concept and design

Experiments at storage ring light sources as well as at next-generation light sources increasingly require detectors capable of high dynamic range operation, combining low-noise detection of single photons with large pixel well depth. XFEL sources in particular provide pulse intensities sufficiently high that a purely photon-counting approach is impractical. The High Dynamic Range Pixel Array Detector (HDR-PAD) project aims to provide a dynamic range extending from single-photon sensitivity to 10{sup 6} photons/pixel in a single XFEL pulse while maintaining the ability to tolerate a sustained flux of 10{sup 11} ph/s/pixel at a storage ring source. Achieving these goals involves the development of fast pixel front-end electronics as well as, in the XFEL case, leveraging the delayed charge collection due to plasma effects in the sensor. A first prototype of essential electronic components of the HDR-PAD readout ASIC, exploring different options for the pixel front-end, has been fabricated. Here, the HDR-PAD concept and preliminary design will be described.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of the CMS Endcap Timing Layer readout chip prototype with charge injection

We present the characterization of a readout Application-Specific Integrated Circuit (ASIC) for the CMS Endcap Timing Layer (ETL) of the High-Luminosity LHC upgrade with charge injection. The ASIC, named ETROC and developed in a 65 nm CMOS technology, reads out a 16× 16 pixel matrix of the Low-Gain Avalanche Detector (LGAD). The jitter contribution from ETROC is required to be below 40 ps to achieve the 50 ps overall time resolution per hit. The analog readout circuits in ETROC consist of the preamplifier and the discriminator. The preamplifier handles the LGAD charge signal with the most probable value of around 15 fC. The discriminator generates the digital pulse, which provides the Time-Of-Arrival (TOA, leading edge) and Time-Over-Threshold (TOT, pulse width) information. The prototype of ETROC (ETROC0) that implements a single channel of analog readout circuits has been evaluated with charge injection. The jitter of the analog readout circuits, measured from the discriminator's leading edge, is better than 16 ps for a charge larger than 15 fC with the sensor capacitance. The time walk resulting from different pulse heights can be corrected using the TOT measurement. The time resolution distribution has a standard deviation of 29 ps after the time-walk correction from the charge injection. At room temperature, the preamplifier's power consumption is measured to be 0.74 mW and 1.53 mW per pixel in the low- and high-power mode, respectively. Finally, the measured power consumption of the discriminator is 0.84 mW per pixel. With the ASIC alone or the LGAD sensor, The characterization performances fulfill the ETL's challenging requirements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Spin-dependent recombination at arsenic donors in ion-implanted silicon

Spin-dependent transport processes in thin near-surface doping regions created by low energy ion implantation of arsenic in silicon are detected by two methods, spin-dependent recombination using microwave photoconductivity and electrically detected magnetic resonance monitoring the direct current through the sample. The high sensitivity of these techniques allows the observation of the magnetic resonance, in particular, of As in weak magnetic fields and at low resonance frequencies (40–1200 MHz), where high-field-forbidden transitions between the magnetic sublevels can be observed due to the mixing of electron and nuclear spin states. Several implantation-induced defects are present in the samples studied and act as spin readout partner. We explicitly demonstrate this by electrically detected electron double resonance experiments and identify a pair recombination of close pairs formed by As donors and oxygen-vacancy centers in an excited triplet state (SL1) as the dominant spin-dependent process in As-implanted Czochralski-grown Si.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Single-Shot Readout and Weak Measurement of a Tin-Vacancy Qubit in Diamond

The negatively charged tin-vacancy center in diamond (SnV − ) is an emerging platform for building the next generation of long-distance quantum networks. This is due to the SnV − ’s favorable optical and spin properties including bright emission, insensitivity to electronic noise, and long spin coherence times at temperatures above 1 K. Here, we demonstrate measurement of a single SnV − electronic spin with a single-shot readout fidelity of 87.4%, which can be further improved to 98.5% by conditioning on multiple readouts. In the process, we develop understanding of the relationship between strain, magnetic field, spin readout, and microwave spin control. We show that high-fidelity readout is compatible with rapid microwave spin control, demonstrating a favorable parameter regime for use of the SnV − center as a high-quality spin-photon interface. Finally, we use weak quantum measurement to study measurement-induced dephasing; this illuminates the fundamental interplay between measurement and decoherence in quantum mechanics, and provides a universal method to characterize the efficiency of color-center spin readout. Taken together, these results overcome an important hurdle in the development of the SnV − -based quantum technologies and, in the process, develop techniques and understanding broadly applicable to the study of solid-state quantum emitters.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The ABC130 barrel module prototyping programme for the ATLAS strip tracker

For the Phase-II Upgrade of the ATLAS Detector [1], its Inner Detector, consisting of silicon pixel, silicon strip and transition radiation sub-detectors, will be replaced with an all new 100% silicon tracker, composed of a pixel tracker at inner radii and a strip tracker at outer radii. The future ATLAS strip tracker will include 11,000 silicon sensor modules in the central region (barrel) and 7,000 modules in the forward region (end-caps), which are foreseen to be constructed over a period of 3.5 years. The construction of each module consists of a series of assembly and quality control steps, which were engineered to be identical for all production sites. In order to develop the tooling and procedures for assembly and testing of these modules, two series of major prototyping programs were conducted: an early program using readout chips designed using a 250 nm fabrication process (ABCN-250) [2,2] and a subsequent program using a follow-up chip set made using 130 nm processing (ABC130 and HCC130 chips). This second generation of readout chips was used for an extensive prototyping program that produced around 100 barrel-type modules and contributed significantly to the development of the final module layout. This paper gives an overview of the components used in ABC130 barrel modules, their assembly procedure and findings resulting from their tests.

47 OTHER INSTRUMENTATION↗

GRAPH — an readout ASIC for large MCP based detectors

We present a programmable 16 channel, mixed signal, low power readout ASIC, having the project historically named Gigasample Recorder of Analog waveforms from a PHotodetector (GRAPH). It is designed to read large aperture single photon imaging detectors using micro channel plates for charge multiplication, and measuring the detector's response on crossed strips anodes to extrapolate the incoming photon position. Each channel consists of a fast, low power and low noise charge sensitive amplifier, which provides a myriad of coarse and fine programmable options for gain and shaping settings. Further, the amplified signal is recorded using, to our knowledge novel, the Hybrid Universal sampLing Architecture (HULA) ADC. A kind of mixed signal double buffer memory, that enables concurrent waveform recording, and selected event digitized data extraction. The sampling frequency is freely adjustable between few kHz up to 125 MHz, while the chip's internal digital memory holds a history 2048 samples for each channel, with a digital headroom of 12 bits. An optimized region of interest sample-read algorithm allows to extract the information just around the event pulse peak, while selecting the next event, thus substantially reducing the operational dead time. The chip is designed in 130 nm TSMC CMOS technology, and its power consumption is around 47 mW per channel.

47 OTHER INSTRUMENTATION↗