Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Radiological”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

Low Level Radon Concentration and Radon Daughter Dose Monitoring in an Arid-zone Waste Store - 20081

Radioactive waste containing predominantly soil and rubble from the clean-up of a former uranium and thorium minerals processing research facility is currently stored at the Woomera Test Range in South Australia awaiting final disposal. Prior to commencing any manipulation of the nearly 10,000 waste drums (205 L or 55 gallon each), radon concentration monitoring and radon daughter dosimetry has been undertaken to (i) gain understanding of the temporal and spatial variation of radon and its daughters within the storage facility, which could provide insights into the radiological source term and (ii) confirm that radiological risks to workers are below the guideline values. A time series of nearly 12 months of detailed observations shows low level radon concentrations with annual average values that are slightly above the average radon concentrations in Australian homes. Peak values in summer are about three times higher than the annual average based on the CRM measurements. Both radon concentrations and annual effective dose are well below the regulatory limits. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Approach to Quality Assurance for Complex Environmental Modeling - 20407

A strong Quality Assurance (QA) program for complex environmental modeling is essential for regulatory and public acceptance and trust, but it does not have to be onerous. Neptune and Company, Inc. (Neptune) has developed a strong QA program that improves transparency, traceability, reproducibility, and therefore, defensibility and trust. Neptune's QA program has evolved over the past 27 years, transitioning from an ad hoc QA program, to a program that is currently Nuclear Quality Assurance-1 (NQA-1) compliant, and will soon be NQA-1/DOE approved for DOE EM modeling work. In addition, Neptune is a qualified laboratory assessor and qualified auditor for reference materials, a proficiency testing provider, and fully complies with the Environmental Protection Agency (EPA) QA program. Neptune's President and CEO, Kelly Black, was recently named the Chairperson of the International Organization for Standardization (ISO) Technical Committee 69, Application of Statistical Methods. A strong QA program has been developed for Neptune's radiological performance assessment (PA) program. Although pieces of their QA program are currently in development, their current program includes document control using Subversion, issue tracking and work flow tracking using JIRA, and transparency and traceability via a system of 'calc sheets' for documentation of all data analysis and modeling combined with 'check print' documentation of QA checking, and rigorous model testing and configuration control. All work is reviewed by an independent subject matter expert who is not associated with the collection and assembly of information, for an internal peer review. The program is enforced with a handful of Standard Operation Procedures (SOPs), Work Instructions, QA Project Plans (QAPPs), and Quality Management Plans (QMPs) that are updated frequently, with required annual training and acknowledgment. In addition, effective communication of modeling approaches and results to clients and stakeholders are integral to their QA program. Many of their models are built using the GoldSim modeling platform, for which their models are well-known for their level of transparency, documentation, and QA traceability. This level of QA is also applied to their process-level models. Neptune has taken some lessons learned from the extremely rigorous QA program required for the Yucca Mountain Project (YMP), and imposed the YMP requirements of complete traceability, transparency, and reproducibility, but avoided the inflexibility of a QA program that likely contributed to the suspect e-mails in 2005 that resulted in loss of trust in the YMP, and in nuclear waste disposal (and nuclear power) in general. There are far too many examples of loss of public trust due to poor QA that could have been easily avoided with a simple and straight-forward QA program combined with stakeholder engagement. The purpose of this paper is to share features of Neptune's Radiological Performance Assessment program QA program, and some of their QA related lessons learned over the past 27 years of QA for complex environmental modeling. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Lessons Learned from Demolition of Hanford's Plutonium Finishing Plant - 20507

U.S. Department of Energy (DOE) contractor CH2M Hill Plateau Remediation Company (CHPRC), a Jacobs owned company, is making significant progress demolishing the Plutonium Finishing Plant (PFP), which has long been known as one of the most hazardous buildings in the DOE Environmental Management Complex (DOE Complex). The facility is located on the Hanford Site and produced plutonium metal during the Cold War. Production was stopped in 1989, the facility was formally shut down in 1996, and material processing was completed in 2004. After approximately 25 years of demolition preparations, open-air demolition of the main portions of the Hazard Category II nuclear facility began in November 2016. To prepare the PFP for demolition, CHPRC employees performed some of the most hazardous work across the DOE Complex. In addition to extensive demolition preparations, including a wide-reaching communication strategy across the Hanford Site, CHPRC implemented robust controls and monitoring during demolition, and when necessary, adjusted demolition practices and sequence to maintain employee safety and project efficiency. Demolition of the main PFP building began in November 2016. The technical complexity, high hazards and radiological concerns have all led to a difficult demolition environment. Following a spread of contamination at the project site beyond the radiological boundaries in December 2017, work was halted and a recovery plan was generated to allow the demolition work to continue. After the implementation of additional controls and concurrence from regulatory agencies and DOE, the demolition was ready to resume work and reinitiated in August 2018. There are a number of lessons learned from the demolition activities and recovery plan process. This paper allows CHPRC and DoE's Richland Operations Office (RL) to share lessons learned and progress to date with other challenging and hazardous projects across the DOE Complex. Understanding the risk acceptance level is critical to execution of any open-air demolition project and is unique to each facility. Four key lessons learned from this project include: 1) plan execution issues, 2) stakeholder communication issues, 3) watching for summit fever and 4) minimizing exposed contaminated surfaces during demolition. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Large Volume Airborne Contamination Monitoring To Support Nuclear Processes' Deactivation and Decommissioning

Current D and D operations at Hanford have demonstrated a flaw in the current state of the art capability of defining airborne contamination boundaries - Airborne particulate emissions of Pu-239 from CM2H operations on the Hanford Pu Finishing Plant were detected well beyond areas controlled for airborne Pu, putting numerous workers at risk for radiological assimilations - Current air samplers and CAM systems were surveying insufficient volumes of air to accurately predict where respiratory protection was required - Hanford is located in a high radon environment, making air monitoring for alpha emitting actinides challenging in high alpha radon induced backgrounds. - Inexpensive HEPA based home and industrial air purifiers filter significantly higher volumes of air than commercially available continuous-air monitoring (CAM) systems. - Inexpensive models capable of filtered air volumes exceeding 1000 times that of a CAM. - Detector system can be built to detect x-rays generated from actinide decay. - Branching ratios of x-rays are 4 orders of magnitude more intense from Plutonium decay than its gamma emissions. - Detector system can be a low resolution systems, as x-ray region of interest is not terribly congested. - Detection systems evaluated will be designed based on slabs of NaI or pixelated NaI or CsI panels. - Simple graphical user interface software will be developed to operate the detection system. - Concept is to deploy some of these air-purifying systems in nonradiological areas around SRNL to confirm radon can be rejected with confidence. - Generate some filters contaminated with plutonium via electroplated Pu or lab generated simulated particles. - then deploy units in known airborne radiological environments to establish systems ability to accurately measure actinide based hot particles Lab analyses will follow up the system analyses to ensure hot particles were correctly identified. Analysis by Scintillation: - Application of scintillation media to the surface of the filters is being explored. - Evaluating slabs of ZnS(Ag), application of powdered ZnS(Cu) and spray on Perkin Elmer Enhance. - Scintillation events would then be digitized with a digital camera and quantified. - Comparing against sensitivity of a PMT or SiPD readout. - Currently evaluating a Thorlabs 8 Megapixel Monochrome Scientific CCD Camera, hermetically sealed cooled package with a wide angle lens. - Wide angle lens allows complete view of HEPA filter from 7 inches away. - Images taken of glow in the dark paint, as well as plutonium-induced fluorescence. - Plutonium was flamed mounted on a 1 inch diameter stainless steel planchet, covered with a layer of mylar and a section of scintillating ZnS obtained from Eljon. - Currently working on reducing signal-to-noise levels to boost sensitivity. - Dark box to hold contaminated or electroplated source covered filters under fabrication. Analysis by x-ray Spectroscopy: - Branching ratios for x-ray emissions from Plutonium isotopes are orders of magnitude more intense than gamma-ray emissions. - The nuclear databases are incomplete on the branching ratios of some of the isotopes. - Evaluating some custom built SrI2 x-ray spectrometers vs a conventional windowed NaI detector. - SrI2 detectors are carbon-composite-windowed 51 mm x 51 mm. - MCNP calculations to establish self absorbance of filter media on 17 keV x-ray. Radon Rejection: - Activated charcoal pre-filter acts as a Radon trap. - Adding a time lapse feature to camera to aid in radon rejection. SRS Plutonium Fuel Form D and D Operations: Currently deploying air sampler to D and D operation of Pu-238 facility at SRS to generate some field samples to analyze.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Filter 'Cook-Off': Filter Selection via Side-by-Side Testing at Actual Process Conditions - 20040

In 2005, the THOR steam reforming fluidized-bed reactor technology was selected by the U.S. Department of Energy for treatment of sodium-bearing waste at the INL. During the final phase of commissioning prior to radiological operations, regeneration of the high temperature filters in the process gas filter (PGF) vessel became ineffective. After approximately 50 days of testing, the differential pressure across the filters began increasing exponentially and the plant had to be shutdown. Subsequent investigation revealed that the Inconel 625 (I625) sintered metal filter media was corroding in the 550 deg. C reducing environment. A pilot plant run tested four candidate replacement filter media. The top candidate was further tested during a long-term pilot plant run to validate the selection. Data from the testing indicate the selected filters will provide reliable service throughout the life of the project, including after in-situ radiological decontamination. This paper presents the data from this effort and reinforces the value of pilot plant testing. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Advancement of Commercial Intumescent Expanding Foams for Deactivation and Decommissioning in the Nuclear Sector - 20198

Florida International University (FIU), in collaboration with The Department of Energy's Office of Environmental Management (DOE-EM), Savannah River National Laboratory (SRNL), and sites across the Savannah River complex, have identified an operational requirement for a fixative technology that is intended to immobilize and/or isolate residual contamination within a 3-dimensional space. Fixation of radiological contamination can reduce worker risk and mitigate potentially hazardous conditions, however nearly every marketed contamination fixative has been found to be flammable; a significant concern in radiological facilities. Coupled with this, industry fixatives are normally used as a thin coating which can present problems when attempting to stabilize irregular geometry or areas that are difficult to access whilst ensuring full coverage. The technical evaluation and advancement of commercial-off-the-shelf (COTS) polyurethane foams has yielded a down-selected candidate that shows potential in meeting the requirements to support deactivation and decommissioning activities. Several performance criteria have been established and tested to progress the technology readiness level towards an active field demonstration (TRL-7). Such criteria include: mechanical failure limits, adhesive and cohesive properties, thermal/fire resilience, determining thermal behavior, ability to immobilize contamination, and a means of non-destructive evaluation of applications. The test scenario examined was targeted towards an application for decommissioning nuclear pipework, in which the down-selected polyurethane foam would act as a barrier to segregate pipework and mitigate the potential for release during cutting, packaging, and storage operations. Testing carried out at SRNL included: mechanical evaluation of tensile, compressive, and adhesion strength by dynamic mechanical analysis (DMA), as well as thermogravimetric analysis (TGA). FIU examined the foam's fixative properties by utilizing phosphorescent europium-dysprosium doped strontium aluminate powder to investigating the extent to which contamination can be immobilized. FIU has also exploited previous successes in the field of intumescent technologies to assess the down-selected foam's tolerance to an extreme fire scenario, while maintaining the ability to effectively mitigate a contamination release. Parallel to this, extensive thermal investigations were carried out to determine the upper boundary of anticipated heat generation during the curing process as heat generation has the potential to compromise rubber parts of contaminated enclosures. These investigations subsequently yielded a promising method for a non-destructive application evaluation by means of infrared thermography. Utilizing the high sensitivity of modern IR cameras, coupled with the heat generated during the curing process of the polyurethane foam, FIU has been exploring the concept of monitoring the external pipe surface for indications of an irregular or abnormal application, thus informing operational decision making. The testing carried out utilized several current 'best fit' ASTM standards, which serve as helpful guidelines for testing, however, a precise definition of the operational parameters and requirements is still necessary. With continued collaboration with SRNL, FIU aims refine said definitions and develop new standards by which this, and other decommissioning technologies, can be accredited by relevant standards based testing. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

The Industry's Long-term, Yet Near-term, Issues: The Need for Radiation Protection Professionals - 20266

Since the discovery of X-rays and radioactivity, the civil use of nuclear technology has thrived for more than a half-century and has matured to be safer and more efficient. A balance between radiological and non-radiological knowledge and experience has been gained and retained through the years. Nevertheless, a slowly developing gap has emerged during the past few decades. National and international data show a declining trend in the existence of health physics programs and associated enrollment and training, which directly impact the pipeline of radiation professionals (i.e., educators, technicians, researchers, and regulators). This decline can be attributed to many factors including the lack of scientific inquisitiveness, declining funding, and the perception that existing protocols are sufficiently protective. Decommissioning and dismantling nuclear facilities is a complex and multi-phased process that generates large quantities of various levels of radioactive waste. With multiple facilities reaching their end of operational life, and others being shut down for economic reasons, the current pipeline for radiation protection experts cannot meet the future's need. Consequently, international organizations have proposed a variety of programs to transfer knowledge of radiation protection principles and practice. While many change-oriented efforts to counteract this trend aim to promote mobility, this is just a partial solution to the actual issue: long-term availability. This paper suggests multidisciplinary collaborations with modern technologies as a path forward to educate young professionals on the diversity of radiation-related applications to retain expert knowledge and foster innovation. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

MH-1A Sturgis Decommissioning and Dismantlement - 20281

The U.S. Army Corps of Engineers (USACE) with its prime contractor, Aptim Federal Services, LLC (APTIM), recycled 5,260 metric tons (11.6 million pounds) of material from Sturgis Barge (Sturgis) during the Decommissioning and Dismantlement of the MH-1A nuclear power reactor. The overall objective of the project was to reduce residual radioactivity associated with MH-1A to levels that permitted release of Sturgis for dismantlement and termination of the Army Reactor Office permit. By effectively applying waste hierarchy's three Rs - reduce, reuse and recycle - the Sturgis project not only minimized the amount of waste that required disposal at landfills, but also reduced the potential for long-term environmental liability emanating from these landfills. The project team completed the physical decommissioning efforts in June 2018 in Galveston, TX. In September 2018, radiological surveys were completed to demonstrate the vessel could be released for shipbreaking. Sturgis was towed from Galveston, TX to Brownsville, TX in late September 2018. Shipbreaking, dismantlement and recycling efforts began in early October 2018 and were completed on 15 March 2019. As part of the decommissioning effort in Galveston, the team shipped 69 shipments (860 metric tons) of low-level radioactive waste and radioactive components to the Waste Control Specialist (WCS) facility in Andrews TX for disposal. Certain radioactive components had to be transferred to the Department of Energy prior to placing the materials into the Federal Waste Facility located within WCS. However, most of the radioactive waste was characterized, profiled, approved and managed under the WCS permitted radioactive waste exemption process authorized and implemented by the Texas Commission on Environmental Quality (TCEQ) and the Radioactive Materials Division. This allows LLRW and LLMW to be shipped as regulated waste and then upon receipt at WCS through satisfying the relevant waste acceptance criteria the waste is exempted and placed into the WCS RCRA permitted cell. An additional 35 shipments (544 metric ton) of contaminated hazardous waste water were transported to U.S. Ecology in Robstown, TX for treatment/disposal. An additional 36 shipments (500 metric tons) of non-hazardous wastewater was sent to Republic Waste Services' facility in Fresno, TX. The disposal of these materials required close coordination with State of Texas regulators. During decommissioning, the project team recycled approximately 270 metric tons (600,000 pounds) of lead and steel. As part of the dismantlement in Brownsville, TX the team recycled approximately 5,000 metric tons (11 million pounds) of ferrous and non-ferrous material, limiting our disposal requirements to about 180 metric tons (400,000 pounds) of material (<4% from entire shipbreaking activity). Although the primary hazard being mitigated by this project was radiological, recycling was always a priority for the project. The team strived to achieve sustainability goals as we implemented this one of a kind project. Scrap metal recycling has a large positive impact on the environment and can also favorably impact project disposal costs. Steel is among the most recycled material in the world. Nearly 40% of the world's steel production is made from scrap. Recycling steel also requires 75% less energy than producing it from raw materials. By using recycled steel rather than virgin materials, 2.33 kg of carbon emissions are eliminated per kg of steel [1]. The project recycled more than 4,500 metric tons (10 million pounds) of steel, which eliminated about 10,400 metric tons (23 million pounds) of CO{sub 2}. By implementing a recycling initiative for the Sturgis project, the team was able to realize cost avoidance for disposal of scrap, cost savings from the metals recycled, plus the project provided benefits to the environment through our recycling efforts. Once the dismantlement was complete, the team prepared a detailed decommissioning closure report, which allowed for the termination of the Army Reactor Decommissioning Permit. While it not only reduced any potential long-term environmental liability, this project to decommission and dismantle a floating nuclear power plant is truly unprecedented - it is a prime example of the USACE mission which is: 'Engineering solutions for the Nation's toughest challenges'. This unique, one of a kind, historical power plant was never designed to be taken apart, and the available information about its construction was lacking in many details. The hazards that required mitigation dictated a painstaking and deliberate process in order to avoid any release to the environment and the community, and to protect the health and safety of the workers involved while keeping the waste hierarchy's three R's - reduce, reuse and recycle at the forefront. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Characterization Strategy of a Limited Number of Radioactive Waste Effluent Tanks in View of Decommissioning a Large Number of Tanks - 20286

In order to organize the D and D of the former effluent treatment facility at the CEA Cadarache Center (France), the key data to gather through the facility characterization are the following:: volumes and masses, liquid/solid distribution and specific activity. By studying the treatment processes and the history of the facility, families of tanks have been defined and a reference tank chosen for investigation in each family. The intrusive investigations (video, residue thickness, dose rate..), the gamma spectrometry measurements carried out on site on the residue samples and radiochemical results collected in laboratories, led us to conclude that there was a relative radiological homogeneity (for specific activity and Am-241/Cs-137 ratio) within each tank. The next step consisted in extrapolating the specific activity evaluated for the reference tanks, to the other tanks of each family by using data such as geometry, dose rate or the function of the tanks within the process. Thus, a cartography of the 130 tanks of the facility is available. Finally, the conclusions drawn from the radiological homogeneity of the tanks and their affiliation to homogeneous, well-identified tank clusters lead to a simple and efficient operational approach for the D and D of the 130 tanks of the facility. Indeed, because of the residue characteristics (homogeneous activity and strong differentiation of Cs/Am ratio), a sample collected when opening the tank, and measured on site by gamma spectrometry will allow us to validate the operational design and the emptying techniques defined during the D and D study phase thanks to the characterization of a limited number of reference tanks. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

The Nature and State of Groundwater Contamination at the Nevada National Security Site: What Have We Learned from Decades of Groundwater Analysis? - 20337

The regulatory framework for remediating radionuclide contamination from underground nuclear testing at the Nevada National Security Site (NNSS) is based on a combination of characterization and modeling studies, monitoring, and institutional controls [1]. Currently, tritium is the largest contributor (∼90%) to the estimated 44.6 million-curie radionuclide inventory resulting from underground testing [2]. Because of its short half-life (12.32 years), its relative contribution reduces below 10% of the total radiologic inventory over the next 120 years as a result of radioactive decay. Although tritium levels are observed well above the Safe Drinking Water Act (SDWA) maximum contaminant levels (MCLs) in groundwater, other radionuclides are well below their MCLs except within the nuclear test near-field (nuclear test cavity and chimney) environment. In fact, most device-derived radionuclides are below their MCL in groundwater even in samples collected from this near-field environment. The distribution of radionuclides following the nuclear detonation greatly influences the availability of potential contaminants for groundwater transport. Tritium is initially distributed in the gas phase, later as tritiated water in steam, and finally as liquid water, and is available to groundwater transport away from the near-field environment. Other radionuclides that are mobile in groundwater are {sup 14}C, {sup 36}Cl, {sup 99}Tc, and {sup 129}I though their radiologic inventory is small when compared to tritium. Many radionuclides (e.g. U, Pu, Am) are incorporated to a significant extent into the melt glass at the bottom of the cavity and are accessible to groundwater primarily through the slow process of glass dissolution. These radionuclides are also adsorbed to the surfaces of the crushed rock within the cavity and chimney which limits their migration in groundwater. Although colloid facilitated transport of radionuclides at the NNSS has been observed [3], radionuclide concentrations decrease with time and migration distances due to desorption and colloid filtration processes. Current studies indicate that radionuclides associated with colloids are unlikely to migrate downgradient from NNSS underground nuclear tests at concentrations above the SDWA MCL [4][5]. The results of over 50 years of sampling, along with an understanding of these post detonation processes, indicate that tritium is the only contaminant of concern downgradient of testing and that even tritium will not exceed its MCL in groundwater after ∼120 years. Although other longer-lived radionuclides may continue to be released slowly from the near-field environment they will likely never reach levels exceeding their MCLs in groundwater downgradient of the NNSS. Groundwater monitoring will continue to verify these observations. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Use of the Manuela 3D/Radiation Scanning Tool at Nuclear Facilities - 20437

Licensees, facility operators and decommissioning contractors have a need for comprehensive, accurate and precise radiological and topographical data to plan and execute safe and efficient Decontamination and Decommissioning (D and D) projects. Traditional approaches rely greatly upon labor and administratively intensive data collection methods that require considerable time and effort to glean the relevant data to plan and perform work in a radiological work area. Orano Decommissioning Services has developed and utilized at French nuclear facilities a lightweight portable scanning instrument called MANUELA (Mobile Apparatus for Nuclear Expertise Localization Assistance). Recently Orano conducted demonstrations at two United States nuclear facilities using MANUELA that may prove useful in areas of the fuel cycle including: - ALARA (As Low As Reasonably Achievable) planning during facility operations; - Scoping and site characterization during the D and D planning phase; - Remedial action support during active decommissioning work; - Radiation and modeling planning for plant modifications; - Support Final Status Survey and demonstration of 'end state' compliance for license termination. MANUELA is currently being evaluated for use during decommissioning of nuclear facilities and could aide in demonstrating compliance with end state criteria after decommissioning. Of particular interest are decommissioning projects planned for various sites across the United States. Most of these sites present unique challenges and opportunities to safely and efficiently decommission in a regulatory compliant manner. The two demonstration site's current conditions of relatively low radiation levels inside containment proved to be ideal platforms to deploy the MANUELA instrument for evaluation of the complex geometries typically found in a nuclear facility. The MANUELA instrument was able to precisely identify local hot spots of the reactor system's primary equipment and was able to simultaneously overlay the dose information onto the scanned 3D images. Using data like this, a licensee would be able to make informed technical and personnel decisions on methods to remediate, shield or properly dispose of the radioactive source term. MANUELA can be used throughout the decommissioning process to validate progress and continue to refine the work activities to optimize the efforts of the crew which reduces downtime waiting for survey results, whereas traditional survey methodology relies on a physical survey to be performed and the data transcribed onto survey maps that are only two dimensional. The traditional format tends to be inaccurate and difficult to interpret the precise location(s) of hot spots or generalized dose rates. The resultant scan also allows the user to know the exact extent of the survey versus transposing information onto a map with only a portion of the map area scanned. MANUELA also compiles all of the relevant survey data into a downloadable table format which includes the measurement identification number, time stamp, point space location on the XYZ plane, and the dose rate value. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Application of Monte Carlo code SHIFT for MSBR dose rate calculations

This paper presents a study that applied the Monte Carlo code SHIFT to calculate the radiological environment within a detailed Molten Salt Breeder Reactor (MSBR) model. It represents one of the first applications of the SHIFT code in stand-alone simulations for non-light water reactors to help demonstrate the code's potential uses in the design, licensing, and operation of advanced reactors. The radiological conditions of the MSBR were modeled when the reactor is at two different operation modes: normal full power and a drained state. The Forward Weighted-Consistent Adjoint Driven Importance Sampling (FW-CADIS) hybrid method in SHIFT was applied successfully to calculate the ex-core neutron and gamma dose rates for the MSBR at full power. Neutron and gamma dose rates within the drain cell were also calculated for the MSBR at the drained state by integrating the source terms obtained from an ORIGEN-S depletion calculation into the SHIFT simulation. The results indicate that in the drained state, the delayed gammas from the depleted fuel salt are the main contributors to the dose rates. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Application of Constellation's best estimate alternate source term methodology

Safety analyses for a nuclear power plants need to consider postulated accidents that results in a risk of accidental release of radiation. The regulations require plant specific safety analysis reports to include an evaluation of the requirements of 10CFR50.67. Such a safety analysis report mandates limits such that calculated radiological consequences at certain locations do not exceed established limits in 10CFR50.67 following a postulated release of radioactivity. Analyses should demonstrate, with reasonable assurance, that these prescribed limits are complied with. Conventional methodologies utilize conservative approaches to address lack of uncertainty quantification in the utilized approaches, methods, and/or inputs. These built-in excess conservatisms often result in with compounding effects and hence overly conservative results in the estimated radiological consequences, which leads to inaccurate margin evaluation for operation and accident mitigation. Therefore, evaluating accurate dose consequences is needed for both operational and safety reasons. This paper illustrates the use of the best estimate source term (BEAST) methodology to the case of the loss of coolant accident (LOCA) dose analysis.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Consequence Management Asset Overview

Presentation summarizing DOE Consequence Management assets available to support state, local, territorial, and tribal partners during a radiological emergency. This presentation will be given at various state engagements, including training and outreach for ingestion pathway exercises, national and regional CM exercises, and trainings for radiological emergency preparedness events as requested.

61 RADIATION PROTECTION AND DOSIMETRY↗

Radiation monitoring devices and associated methods

Radiation monitoring devices and associated methods are described. According to one aspect, a radiation monitoring device includes a housing configured to pass radiation emitted from a radiological source located in proximity to the radiation monitoring device, a radiation detector configured to receive the radiation emitted from the radiological source and to generate information regarding the radiation, and communications circuitry configured to communicate the information regarding the radiation in a plurality of communications at a plurality of different moments in time externally of the radiation monitoring device.

Burghard, Brion J.↗

(Paper) TRIPWIRE: Multi-modal Distributed Sensing For Repository Verification

Underground geological repositories for storing used nuclear fuel are being planned and developed around the world. Research is being performed to understand technical aspects of sealing entombed materials and underground repositories to ensure the radiological and nuclear materials remain contained. To support safeguards verification for these facilities research at Idaho National Laboratory (INL) is underway to develop and demonstrate a multi-modal sensor system, TRIPWIRE, for containment verification in inaccessible radiological and nuclear waste repositories. The TRIPWIRE system will continuously monitor ionizing radiation and electromagnetic fields in the vicinity of emplaced nuclear materials buried in a repository, reporting on disturbances with a real-time alarm control station. The system will use long-length scintillating fiber bundles (SFBs) to perform area radiation monitoring; these will be coupled to kilometer-scale multimodal optical communication fibers – all light sensors and electronic components used with this system will be located above ground. Electromagnetic fields, and changes in local dielectric conditions caused by intrusion and soil movement, will be monitored using commercial grade, ported "leaky" coaxial cables (PCCs), with control electronics also located above ground. Tamper-indicating self-diagnostic assessments will be done using optical and electronic time domain reflectometry in the SFBs and PCCs, respectively. The result will be a long, kilometer-scale multi-modal SFB-PCC system. Simulation and modeling are being used to inform the work and a demonstration of the system's utility is planned at a nuclear storage facility in the future.

98 - NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL↗

Insulation Activation and Contamination in Low-Power Experiments

Among the diverse advanced nuclear reactor concepts being developed are designs that expect to operate at much higher temperatures than conventional light-water reactors, and therefore require alternative materials for components capable of withstanding these extreme temperatures. Insulation is one such component where alternative high-temperature industrial composites are being considered. Low-power experiments can provide an opportunity for advancing our understanding of material behavior under irradiation; however, these experiments are not without occupational hazards. The focus of this paper is the potential for activation of insulating composites when exposed to neutron fluence during reactor experiments, and to discuss the subsequent contamination of the testing area. This paper will also discuss practical measures for preventing the creation and inhalation of activated particulate matter (i.e., dust), such as engineering and administrative controls and personal protective equipment. This paper evaluates the suitability of several insulation materials for use in reactor experiments based on their activation from neutron irradiation. The materials considered are Pyrogel XTE by Aspen Aerogel, Cerablanket and Kaowool by Morgan Advanced Materials, Thermo-12 Gold by Johns Manville, and Maxsil CF6-2000 by McAllister Mills. Although these materials are not yet widely used in the nuclear industry, they are common in other industries due to their thermal insulating properties. These materials produce dust while handling that can pose health and safety hazards, which could be further exacerbated by activation. The analysis presented in this paper utilizes a deterministic method developed to predict the activation source term of the provided insulation materials. The method calculates the atomic density of each element within the composites and simulates their exposure to a specified neutron flux density representative of low power experimental conditions. During the irradiation phase and throughout the extensive cooling period, neutron absorptions and nuclear decays are tracked for relevant isotopes. The residual activity within each composite is then assessed to identify the material with the lowest potential radiological hazard to workers. Dust will be created during installation and removal of insulating materials and may also be generated during the experiment. Contamination of surrounding surfaces due to dispersion is highly likely unless preventative measures are taken. The results of this analysis are used to estimate an internal dose from inhalation of activated dust, which is significantly lower than the allowable whole-body dose. However, the risk of internal exposure may increase if the dust becomes a transport vector for nuclear material. The goals of this paper are to enhance the understanding of the potential activation and contamination hazards from the use of these insulating materials in low-power nuclear experiments and to foster safer work environments through informed decision-making and strategic planning. This work ultimately contributes to a broader understanding of how new non-nuclear materials for advanced reactors impact the radiological safety of co-located workers, helping to ensure the responsible management of radioactive materials during installation and decommissioning activities.

12 - MGMT OF RADIOACTIVE AND NON-RADIOACTIVE WASTE↗

Idaho National Laboratory’s Mobile Hot Cell Transportation: Engineering Solutions for Global Disused Sealed Radioactive Sources.

Title: Idaho National Laboratory’s Mobile Hot Cell Transportation: Engineering Solutions for Global Disused Sealed Radioactive Sources. Abstract: The Mobile Hot Cell (MHC), currently under development by Idaho National Laboratory (INL) for the Off-Site Source Recovery Project (OSRP), is designed to help international partners meet the unique challenges of end-of-life radioactive material management. The MHC will provide a critical resource for countries that require assistance securing and disposing of Disused Sealed Radioactive Sources (DSRS) and orphaned sources in challenging environments, allowing these sources to be secured against misuse and nefarious activities. The MHC is a rapidly deployable system for conditioning and preparing end-of-life radioactive sources for transportation or storage. It is designed to handle sources of up to 1,000 Ci Co-60 equivalent while maintaining full radiological and biological containment. It will be deployable within 48 hours of an alert, making it ideal for emergency situations. The MHC features an operational suite for control, support racks for electronics, pneumatics, and welding systems, and a modular robust steel structure providing radiological shielding and internal robotic support. This design allows configurations for multiple device types to be conditioned and the ability to safely manage routine issues such as leaking or damaged sources. The MHC has been designed with the transportation challenges of rapid deployment to difficult environments in mind. The system weighs approximately 150,000 pounds, with individual systems breaking down into pieces not exceeding 20,000 pounds. Components are to be transportable on standard 20ft ISO containers, with shielding shells on 20ft flat racks. It is estimated that a total of eight containers and flat racks will be required. The use of 20ft containers, as opposed to 40ft containers, minimizes the impact on less developed road infrastructures, enabling the MHC to be positioned in constrained environments such as hospital parking lots. The system’s modularity also allows for deployment using smaller equipment, such as a 10-ton boom truck or forklift, which is crucial given the potential logistical challenges in different countries. This transportation strategy, evaluated in collaboration with Utah State University, ensures the MHC can be deployed via ground, rail, sea, or air, addressing the primary concern of international transport logistics.

99 - GENERAL AND MISCELLANEOUS↗