Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “REFRIGERATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

From Waste-Heat Recovery to Refrigeration: Compositional Tuning of Magnetocaloric Mn 1+ x Sb

Magnetic refrigeration, as well as waste-heat recovery, can be accomplished through the magnetocaloric effect, where temperature changes the magnetic state of a material or vice versa. Promising magnetocaloric materials display large changes in magnetic entropy (ΔS M ) upon application of a moderate magnetic field and are often associated with magnetic materials possessing some degree of magnetostructural coupling. In such compounds, the magnetic transition is coupled to some structural transition at the ordering temperature, and indicators for these are readily calculated by the magnetic deformation proxy Σ M . MnSb, with a Curie temperature T C = 577 K, has a calculated magnetic deformation of Σ M = 5.9% and is a promising candidate material for waste-heat recovery. The temperature dependence of structural, magnetic, and magnetocaloric properties of Mn 1+ x Sb, where $x$ is a tunable amount of interstitial Mn, is studied here. specifically, excess Mn is incorporated as an interstitial whose magnetic moment is antialigned with the stoichiometric Mn, and the excess Mn has the effect of lowering T C , such that the Curie temperature can be tuned from 577 K to nearly room temperature at 318 K for $x$ = 0.2. For $x$ = 0.0, 0.1, and 0.2, values of ΔS M under a maximum magnetic field $H$ = 5 T are found to be 3.65, 3.00, and 2.83 J K -1 kg -1 , respectively. While the maximum ΔS M decreases with $x$, the high refrigerant capacity a more holistic measure of performance-is retained in this highly tunable system.

36 MATERIALS SCIENCE↗

Interface and Thermophysical Properties of R 32 Refrigerant

Driven by the urgent demand for efficient cooling in microelectronics and advanced thermal management systems, difluoromethane (R32/CH 2 F 2 ) has emerged as a promising candidate owing to its favorable thermophysical properties, including high heat transfer efficiency and low viscosity. While bulk properties such as density, viscosity, and thermal conductivity have been widely studied, interfacial properties, including surface tension and interfacial thickness, remain comparatively underexplored, despite their importance in phase-transition dynamics. Here, we perform molecular dynamics (MD) simulations from 180 to 300 K using an optimized transferable force field for fluoropropenes with enhanced electrostatics to assess both bulk and interfacial behavior of R32. Simulations reproduced density within ±2.1%, viscosity within 3.05%, and thermal conductivity within 7.41% of NIST reference data. Heat capacities (C p and C v ) were predicted within 5%. For interfacial properties, surface tension trends were reproduced within 13.58% deviation, and the vapor–liquid coexistence curve closely matched reference data, yielding a critical temperature of 345.7 K (1.6% deviation) and a critical density of 0.397 g/cm 3 (6.4% deviation). Importantly, the vapor–liquid interface exhibited pronounced temperature-dependent broadening across the 180–290 K range. This behavior correlates with increasing molecular kinetic energy, reduction in intermolecular cohesive interactions, and a progressive loss of preferential dipole alignment, which collectively enhance thermal fluctuation amplitudes at elevated temperatures. These validated results provide predictive molecular-level insights, particularly for interfacial properties that remain less characterized. By reducing property prediction errors in key parameters such as critical temperature, this work provides reliable inputs for heat-exchanger and system models. Such correlations can support optimized component sizing, improved performance, and reduced refrigerant charge. Beyond R32, the methodology offers a transferable framework for blended and next-generation low-GWP refrigerants, contributing to sustainable thermal management aligned with the 2027 EU F-Gas regulation and 2030 Kigali Amendment.

Fluids↗

Solid-state optical refrigeration to sub-100 Kelvin regime

We report that since the first demonstration of net cooling twenty years ago, optical refrigeration of solids has progressed to outperform all other solid-state cooling processes. It has become the first and only solid-state refrigerator capable of reaching cryogenic temperatures, and now the first solid-state cooling below 100 K. Such substantial progress required a multi-disciplinary approach of pump laser absorption enhancement, material characterization and purification, and thermal management. Here we present the culmination of two decades of progress, the record cooling to ≈91K from room temperature.

36 MATERIALS SCIENCE↗

Commissioning of helium refrigeration system at JLab for 12 GeV upgrade

The new 4.5 K refrigerator system added to the Jefferson Lab (JLab) Central Helium Liquefier (CHL) for the 12 GeV upgrade will double its previous capacity. It includes a 4.5 K cold box system and compressor system with associated oil removal and gas management systems. At its maximum capacity condition, this new system supports an additional 238 g/s 30 K 1.16 bar cold compressor return flow, a 15 g/s 4.5 K liquefaction load and a 12.6 kW 35–55 K shield load. Five more design conditions, ranging from liquefaction to refrigeration and a stand-by/reduced load state, were specified for the sizing and selection of its components. The cold box system is comprised of a 300–60 K vertical cold box that incorporates a liquid nitrogen pre-cooler and a 60–4.5 K horizontal cold box housing seven turbines that are configured in four expansion stages including one Joule-Thompson expander. The helium compression system has five compressors to support three pressure levels in the cold box. This paper will briefly review the salient 4.5 K system design features and discuss the recent commissioning results.

42 ENGINEERING↗

Commissioning and operational results of helium refrigeration system at JLab for the 12GeV upgrade

The new 4.5 K refrigerator system at the Jefferson Lab (JLab) Central Helium Liquefier (CHL-2) for the 12 GeV upgrade was commissioned in late spring of 2013, following the commissioning of the new compressor system, and has been supporting 12 GeV LINAC commissioning since that time. Six design modes were tested during commissioning, consisting of a maximum capacity, nominal capacity, maximum liquefaction, maximum refrigeration, maximum fill and a stand-by/reduced load condition. The maximum capacity was designed to support a 238 g/s, 30 K and 1.16 bar cold compressor return flow, a 15 g/s, 4.5 K liquefaction load and a 12.6 kW, 35-55 K shield load. The other modes were selected to ensure proper component sizing and selection to allow the cold box to operate over a wide range of conditions and capacities. The cold box system is comprised of two physically independent cold boxes with interconnecting transfer-lines. The outside (upper) 300-60 K vertical cold box has no turbines and incorporates a liquid nitrogen pre-cooler and 80-K beds. The inside (lower) 60-4.5 K horizontal cold box houses seven turbines that are configured in four expansion stages including one Joule-Thompson expander and a 20-K bed. The helium compression system has five compressors to support three pressure levels in the cold box. This paper will summarize the analysis of the test data obtained over the wide range of operating conditions and capacities which were tested.

Knudsen, Peter N.↗

LCLS-II Helium Refrigeration System Commissioning Results

SLAC National Accelerator Laboratory has upgraded to LCLS-II, featuring a 4 GeV superconducting linear accelerator composed of 37 cryomodules and two large helium refrigeration systems with a cooling capacity of 4 kW at 2.0 K. The LCLS-II Helium Refrigeration System (HRS) consists of two compressor stations, each with a power of approximately 4.5 MW, two 4.5 K cold boxes, each with a power of 18 kW equivalent at 4.5 K, and two sets of cold compressors that can each produce a flow of 230 g/s at 31 mbar (2.0K). Performance tests of the HRS were meticulously planned and successfully carried out, with results demonstrating that it exceeded the process requirements for LCLS-II operations. This paper provides a detailed presentation of the LCLS-II HRS performance and the challenges encountered during the commissioning phase.

42 ENGINEERING↗

Modeling of Pressure Exchanger for Energy Recovery on Trans Critical CO2 Refrigeration Cycle

Pressure exchanger is a device used to recover energy from high pressure working fluid in systems like Reverse Osmosis water desalination. The pressure exchanger enables the high pressure fluid to transfer portion of its energy to the low pressure fluid by tran sferring the fluid pressure. This working concept can be applied to systems where there is a significant pressure variation of the working fluid along the system. Trans critical CO 2 refrigeration system is a good example for significant pressure variation during the flow path. The high pressure CO 2 exiting the condenser can be recovered by the low pressure CO 2 upstream of the compressor using a pressure exchanger to increase the system overall efficiency. The proposed research is to numerically simulate a prototype pressure exchanger for trans critical CO 2 refrigeration system. The focus of this study is to understand the thermo fluid behavior of the system when CO 2 is used as the working fluid. Contour plots of velocity and pressure are presented for qualitative analysis.

Elatar, Ahmed↗

Universal Automated Refrigerator Door Opener

This creation is used for standard energy performance tests of household and commercial refrigerators and other refrigeration equipment. It automates the door opening at a preset duration and velocity specified by the test procedure.

Wang, Duo↗

Additive Manufacturing of Tooling for Refrigeration Cabinet Foaming Processes

The primary objective of this project was to leverage the Big Area Additive Manufacturing (BAAM) process and materials into a long term, quick change tooling concept to drastically reduce product lead and development timelines and costs. Current refrigeration foam molds are complicated to manufacture involving casting several aluminum parts in an approximate shape, machining components of the molds and post fitting and shimming of the parts in an articulated fixture. The total process timeline can take over 6 months. The foaming process is slower than required for production, therefore multiple fixtures, 10 to 27, are required per refrigerator model. Molds are particular to a specific product configuration making mixed model assembly challenging for sequencing, mold changes or auto changeover features. The initial goal was to create a tool leveraging the ORNL materials and additive process to build a tool in 4 to 6 weeks or less. A secondary goal was to create common fixture cores and provide lightweight fixture sections that could be revised in a very short time to increase equipment flexibility reduce lead times, lower the barriers to first production trials, and reduce tooling costs.

3d Printing↗

Compare optimized performance results for packaged RTU using all alternative refrigerants FY17 1st Quarter Milestone Report

Based on the laboratory investigation in FY16, for R-22 and R-410A alternative low GWP refrigerants in two baseline rooftop air conditioners (RTU), we used the DOE/ORNL Heat Pump Design Model to model the two RTUs and calibrated the models against the experimental data. Using the calibrated equipment models, we compared the compressor efficiencies, heat exchanger performances. An efficiency-based compressor mapping method was developed, which is able to predict compressor performances of the alternative low GWP refrigerants accurately. Extensive model-based optimizations were conducted to provide a fair comparison between all the low GWP candidates by selecting their preferred configurations at the same cooling capacity and compressor efficiencies.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

ECC Refrigerator: Develop a system model using electrochemical (ECC) compressor and metal hydride (MH) heat exchangers- FY18 2nd Quarter Milestone Report

This report describes equations for modeling electrochemical compressors and metal hydride heat exchangers. We developed two new component models into the HPDM model library. Two system simulations were conducted, one was a water heating system using LaNi5, and the other was a refrigeration system using V0.85Ti0.1Fe0.05. The simulations demonstrated that COPs of the electrochemical compression systems decreased drastically with increasing the electric current and capacity, due to reduced electrochemical compression efficiency at larger ohm resistance loss. Cyclic loss caused by the metal hydride and heat exchanger mass had a secondary effect on the system efficiency. Elimination of the heat exchanger cyclic loss could enhance the water heating COP of the LaNi5 system by 12% and increase the refrigeration COP of the V0.85Ti0.1Fe0.05 system by 7%.

42 ENGINEERING↗

A Critical Literature Review of Defrost Technologies for Heat Pumps and Refrigeration Systems

When the operating conditions are extremely cold and humid and the surface temperature of the heat exchanger well below the freezing point (lower than the dew point temperature of the air) moisture from the air stream will freeze on the surface after condensation and the frost will start growing. The frost growth degrades the performance of the system considerably. It hinders the airflow and increases the pressure drop through the coil which means more fan power is requires for to maintain the desired flow rate. With reduced flow rate due to the increase of pressure drop, system’s capacity drops rapidly. In the case of heat pump the capacity of the evaporator decreases due to the airflow drop, which reduces the overall heating capacity and coefficient of performance of the heat pump. Additionally, the frost layer increases the thermal resistance to the heat transfer between the air and refrigerant. The reduction in airflow and increased thermal resistance reduces the heat energy extracted by the evaporator and decreases the heat pump capacity and efficiency. Similar process is observed for the cooling coils of commercial refrigeration system where the frost growth can dramatically reduce the system capacity. Once the performance reaches its minimum acceptable stage, a defrost process is introduced to remove the frost layer and to achieve the performance at the start of the cycle. The frost defrost process is repeated continuously. Overall the frost growth is highly undesired phenomena which can cause considerable reduction in performance of the system.

42 ENGINEERING↗

BTO 3.1.2.55 Milestone Report - Shortlist of potential sensors to be used to detect refrigerant maldistribution in HXs

This report lists the sensors that will be considered for this project to detect refrigerant maldistribution. Along with the measurement method, the table in the report also shows the unique advantages and disadvantages that each sensor has which are relevant to the planned benchtop experimental setup that will be fabricated to study refrigerant maldistribution. The actual setup will likely be fabricated with a combination of the sensors listed.

42 ENGINEERING↗

Load Flexibility Analysis of Residential HVAC and Water Heating and Commercial Refrigeration

The emergence of connected devices and the Internet of Things has opened the door to the concept of widespread use of building equipment for load-side flexibility. This stems from the increased use of distributed and clean energy resources for electric generation and the growing demand for a more resilient and reliable grid. A significant challenge associated with the use of building equipment as a distributed energy resource is quantifying the magnitude of power or energy flexibility. Unlike batteries that have well-defined and relatively constant capacity and maximum charge/discharge rates, building equipment often has characteristics that vary based on external factors (e.g., weather or occupant behavior). This makes quantifying the availability and flexibility of these resources difficult. Controlling a fleet of equipment while minimizing any adverse impacts to the occupants (e.g., discomfort or food spoilage) is a nontrivial matter. Although there are many different control methodologies available, this study focuses on two: priority-based control (PBC) and model-predictive control (MPC). These were selected because they represent two ends of the control spectrum. PBC is a relatively simple control strategy that requires only the current state of the devices to be controlled and an estimate of how much power each device consumes when turned on. MPC is much more complex and requires a model of the system and forecasts of any disturbances that influence the system. Because MPC has a predictive element, it can prepare for a desired response before the event and therefore is expected to provide a more optimal control relative to PBC. Both MPC and PBC are compared with a baseline simulation that uses feedback control typical of the thermostatically controlled devices being evaluated. This report investigates the load flexibility of three building systems: residential air conditioners, residential water heaters, and commercial refrigeration. Air heating and cooling and water heating account for 45% of residential electricity use, making them good candidates for providing load flexibility. Refrigeration in commercial buildings accounts for 16% of commercial building electricity use, making it another good candidate. Simplified models of each system were generated and validated based on measured data from actual equipment. These models were used to simulate the thermal and power response of the systems using PBC and MPC for a fleet of devices trying to achieve a variety of different responses, including hourly load shed, hourly load up, and daily peak demand reduction. Significant findings from each piece of equipment follow.

42 ENGINEERING↗

Compressor is A Sensor: A Universal Refrigerant Charge Fault Detection and Diagnostics Method Based on Pump Down Operation

The primary goal of this report is to develop a universal charge fault detection method that requires only a few experimental data with high prediction accuracy. Currently, pump-down operations is typical practices by HVAC technicians when they need to open the refrigerant circuit to make a repair. In addition, compressors have a built-in low-pressure cut-off protection function, and the compressor performance maps are commonly available from manufacturers. The new charge fault detection and diagnostics method innovatively utilizes the typical pump down operation, the compressor’s low-pressure cut-off protection, and the compressor performance map. It does not require any geometry information of heat exchangers, refrigerant lines, or charge buffers.

42 ENGINEERING↗

Implementation of a Web Interface to Display Real-Time Statistics of a Dilution Refrigerator

The purpose of the project is to communicate with a Bluefors control unit and extract data. The Bluefors control unit is a piece of experimental equipment that measures various different data points in a dilution refrigerator and stores them. The goal was to access the control unit using the websockets library in Python. After accessing the control unit, the goal was to export the data to a web page in HTML/CSS. The tools that were used changed throughout the project. Python was used to communicate with the Bluefors unit via JSON requests and JSON objects, then the Python hosted its own websocket server to act as a proxy server to allow for the web page to access the data. This was done to bypass SSL verification. Then, the web page, which was created using JavaScript, React, Next.js, and NodeJS, accesses the proxy server to import the data from the dilution refrigerator and display the values in real time on the page.

Rasheed, Hammad↗

MaxTech HPWH Using Ultra-low GWP Refrigerant

Heat pump water heaters (HPWHs) are a proven technology for water heating that has been commercialized. The adoption of HPWHs for domestic and commercial water heating is growing rapidly because of superior performance compared with that of alternative water heating methods. Whereas most existing systems use R-134a as a working refrigerant, significant interest exists for deploying low global warming potential refrigerants to minimize environmental impacts.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗